Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 522 - 530
1 Apr 2017
Bus MPA van de Sande MAJ Taminiau AHM Dijkstra PDS

Aims

To assess complications and failure mechanisms of osteoarticular allograft reconstructions for primary bone tumours.

Patients and Methods

We retrospectively evaluated 38 patients (28 men, 74%) who were treated at our institution with osteoarticular allograft reconstruction between 1989 and 2010. Median age was 19 years (interquartile range 14 to 32). Median follow-up was 19.5 years (95% confidence interval (CI) 13.0 to 26.1) when 26 patients (68%) were alive. In addition, we systematically searched the literature for clinical studies on osteoarticular allografts, finding 31 studies suitable for analysis. Results of papers that reported on one site exclusively were pooled for comparison.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1674 - 1681
1 Dec 2016
Verdegaal SHM van Rijswijk CS Brouwers HFC Dijkstra PDS van de Sande MAJ Hogendoorn PCW Taminiau AHM

Aims

The purpose of this retrospective study was to differentiate between the MRI features of normal post-operative change and those of residual or recurrent disease after intralesional treatment of an atypical cartilage tumour (ACT)/grade I chondrosarcoma.

Patients and Methods

We reviewed the case notes, radiology and histology of 75 patients, who had been treated for an ACT/grade I chondrosarcoma by curettage, phenolisation and bone allografting between 1994 and 2005. The first post-operative Gd-enhanced MRI scan was carried out within one year of surgery. Patients had a minimum of two scans and a mean follow-up of 72 months (13 to 169). Further surgery was undertaken in cases of suspected recurrence.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1528 - 1532
1 Nov 2008
Verdegaal SHM Corver WE Hogendoorn PCW Taminiau AHM

Surgery is considered to be the most effective treatment for cartilaginous tumours. In recent years, a trend has emerged for patients with low-grade tumours to be treated less invasively using curettage followed by various forms of adjuvant therapy. We investigated the potential for phenol to be used as an adjuvant. Using a human chondrosarcoma-derived cartilage-producing cell line OUMS-27 as an in vitro model we studied the cytotoxic effect of phenol and ethanol. Since ethanol is the standard substance used to rinse phenol out of a bone cavity, we included an assessment of ethanol to see whether this was an important secondary factor with respect to cell death. The latter was assessed by flow cytometry.

A cytotoxic effect was found for concentrations of phenol of 1.5% and of ethanol of 42.5%. These results may provide a clinical rationale for the use of both phenol and ethanol as adjuvant therapy after intralesional curettage in low-grade central chondrosarcoma and justify further investigation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 460 - 466
1 Apr 2006
Keizer SB Kock NB Dijkstra PDS Taminiau AHM Nelissen RGHH

This retrospective study describes the long-term results of core decompression and placement of a non-vascularised bone graft in the management of avascular necrosis of the femoral head. We treated 80 hips in 65 patients, 18 by a cortical tibial autograft and 62 by a fibular allograft. The mean age of the patients was 36 years (sd 13.2). A total of 78 hips were available for evaluation of which pre-operatively six were Ficat-Arlet stage 0, three stage I, 31 stage IIA, 16 stage IIB, 13 stage III and nine stage IV.

A total of 34 hips (44%) were revised at a mean of four years (sd 3.8). Survivorship analysis using a clinical end-point showed a survival rate of 59% five years after surgery. We found a significant difference (p = 0.002) in survivorship, when using a clinical and radiological end-point, between the two grafts, in favour of the tibial autograft. We considered this difference to be the result of the better quality and increased volume of tibial bone compared with that from the trochanteric region used with the fibular allograft.

This is a relatively simple, extra-articular and reproducible procedure. In our view core decompression, removal of the necrotic tissue and packing of the cancellous grafts into the core track are vital parts of the procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1009 - 1014
1 Sep 2002
Deijkers RLM Bloem RM Hogendoorn PCW Verlaan JJ Kroon HM Taminiau AHM

Low-grade surface tumours of bone may theoretically be treated by hemicortical resection, retaining part of the circumference of the cortex. An inlay allograft may be used to reconstruct the defect. Since 1988 we have performed 22 hemicortical procedures in selected patients with low-grade parosteal osteosarcoma (6), peripheral chondrosarcoma (6) and adamantinoma (10).

Restricted medullary involvement was not a contraindication for this procedure.

There was no evidence of local recurrence or distant metastasis at a mean follow-up of 64 months (27 to 135). Wide resection margins were obtained in 19 patients. All allografts incorporated completely and there were no fractures or infections. Fractures of the remaining hemicortex occurred in six patients and were managed successfully by casts or by osteosynthesis. The functional results were excellent or good in all except one patient.

Hemicortical procedures for selected cases of low-grade surface tumours give excellent oncological and functional outcomes. There was complete remodelling and fewer complications when compared with larger intercalary procedures. The surgery is technically demanding but gives good clinical results.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1015 - 1019
1 Sep 2001
van Dam MS Kok GJ Munneke M Vogelaar FJ Vlieland TPMV Taminiau AHM

A continuous ambulatory activity monitor allows objective measurement of the amount and intensity of physical activity. We examined the reliability and validity of this device in the assessment of seven aspects of function over a period of 24 hours in 20 patients who had undergone limb salvage or amputation for a tumour in the leg.

The test-retest reliability was determined by undertaking identical assessments on two separate days. The measurements were compared with other indicators of functional status and quality of life in order to determine the validity of the monitor.

Its reliability was satisfactory, with intraclass correlation coefficients ranging from 0.65 to 0.91. Significant correlations were seen between the ‘time spent walking’ and the Musculoskeletal Tumor Society rating scales and the Rand-36 physical functioning score. There was also a significant association between the ‘movement intensity during walking’ and the Musculoskeletal Tumor Society score. The satisfactory reliability and validity of the monitor shows considerable promise for its use as a device for measuring physical activity objectively in patients after surgery for limb-salvage or an amputation.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 538 - 544
1 May 1999
Deijkers RLM Bouma GJ van der Meer-Prins EMW Huysmans PE Taminiau AHM Claas FHJ

We analysed the cellular immune response in ten transplantations of different massive bone allografts, of which five had a poor clinical outcome. Cytotoxic T lymphocytes (CTL) and T helper lymphocytes (TH) against mismatched donor antigens were found in all patients. More importantly, CTL with a high affinity for donor antigens were found in five cases. High-affinity CTL need no CD8 molecule to stabilise the antigen binding and are strongly associated with rejection of heart and corneal transplants. Even after removal of most of the bone-marrow cells, we found high-affinity CTL and high TH frequencies. This T-cell response could be detected over a period of years.

We conclude that frozen bone allografts can induce high-affinity donor-specific CTL. The present assay allows qualification and quantification of the levels of CTL and TH in the blood. This approach may be helpful in studying the effect of the immune response on the outcome of the graft.