Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
The Bone & Joint Journal
Dates
Year From

Year To
The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 639 - 640
1 Jul 1990
Messieh S Fowler P Munro T

Destruction of the articular cartilage is the first change seen on gross examination of the knee in osteoarthritis. Weight-bearing radiographs are conventionally taken with the knee in full extension. Biomechanical studies have shown, however, that the major contact stresses in the femorotibial articulation occur when the knee is flexed about 28 degrees. Arthroscopy has confirmed that cartilage loss occurs in a more posterior portion of the femoral condyles than is revealed by radiographs taken in full extension. The 'standing tunnel view' is a weight-bearing postero-anterior radiograph taken with the knee in 30 degrees of flexion. The radiographs of 64 patients have been used to compare the conventional with the standing tunnel view. In 10 knees in which the conventional view suggested normal cartilage the standing tunnel view revealed severe degeneration.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 431 - 434
1 May 1990
Phillips T Messieh S McDonald P

A leading problem with cementless hip replacement is thigh pain, probably due to some degree of loosening. This is most pronounced during activities such as stair climbing or getting up from a chair. Our study compares the immediate fixation of three stems in widespread clinical use, using a cadaver test simulation in which the femur was horizontal, and cyclic forces acted vertically downward on the prosthetic head with gradual increments of load. We implanted and tested 18 pairs of femurs, making analyses between stem types by right to left comparisons. We found no statistically significant differences in loosening between cementless AML and PCA prostheses, but cemented stems withstood greater loads than uncemented stems by a factor of five or more.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 750 - 755
1 Nov 1988
Phillips T Messieh S

We have analysed the clinical results of a cementless hip replacement using a Moore stem with a smooth surface, and correlated these results with the radiological changes. Forty-two consecutive arthroplasties in 41 patients were studied prospectively and reviewed at a minimum of two and up to six years; 63% had a good clinical result, 18.5% a fair result, and 18.5% a poor result. Thigh pain on weight-bearing was the main problem and was due to loosening of the stem. We caution against the use of this implant in arthritic patients, in whom a good result can be obtained more predictably with cement fixation.