Advertisement for orthosearch.org.uk
Results 1 - 50 of 736
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1669 - 1677
1 Nov 2021
Divecha HM O'Neill TW Lunt M Board TN

Aims. To determine if primary cemented acetabular component geometry (long posterior wall (LPW), hooded, or offset reorientating) influences the risk of revision total hip arthroplasty (THA) for instability or loosening. Methods. The National Joint Registry (NJR) dataset was analyzed for primary THAs performed between 2003 and 2017. A cohort of 224,874 cemented acetabular components were included. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using log-binomial regression adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, operating surgeon grade, surgical approach, polyethylene crosslinking, and prosthetic head size. A competing risk survival analysis was performed with the competing risks being revision for other indications or death. Results. The distribution of acetabular component geometries was: LPW 81.2%; hooded 18.7%; and offset reorientating 0.1%. There were 3,313 (1.5%) revision THAs performed, of which 815 (0.4%) were for instability and 838 (0.4%) were for loosening. Compared to the LPW group, the adjusted subhazard ratio of revision for instability in the hooded group was 2.31 (p < 0.001) and 4.12 (p = 0.047) in the offset reorientating group. Likewise, the subhazard ratio of revision for loosening was 2.65 (p < 0.001) in the hooded group and 13.61 (p < 0.001) in the offset reorientating group. A time-varying subhazard ratio of revision for instability (hooded vs LPW) was found, being greatest within the first three months. Conclusion. This registry-based study confirms a significantly higher risk of revision after cemented THA for instability and for loosening when a hooded or offset reorientating acetabular component is used, compared to a LPW component. Further research is required to clarify if certain patients benefit from the use of hooded or offset reorientating components, but we recommend caution when using such components in routine clinical practice. Cite this article: Bone Joint J 2021;103-B(11):1669–1677


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 825 - 826
1 Jul 2008
Oswald TF Gould FK

The routine administration of prophylactic antibiotics for dental interventions to prevent haematogenous spread of infections to prosthetic joints is a contentious issue. In this editorial we discuss the potentially harmful effects of this practice and propose an alternative solution


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 372 - 377
1 Apr 2019
Zagra L Villa F Cappelletti L Gallazzi E Materazzi G De Vecchi E

Aims. Leucocyte esterase (LE) has been shown to be an accurate marker of prosthetic joint infection (PJI), and has been proposed as an alternative to frozen section (FS) histology for intraoperative diagnosis. In this study, the intraoperative assessment of LE was compared with FS histology for the diagnosis of prosthetic hip infection. Patients and Methods. A total of 119 patients undergoing revision total hip arthroplasty (THA) between June 2015 and December 2017 were included in the study. There were 56 men and 63 women with a mean age of 66.2 years (27 to 88). Synovial fluid was collected before arthrotomy for the assessment of LE using enzymatic colourimetric strips. Between five and six samples were stained with haematoxylin and eosin for FS histology, and considered suggestive of infection when at least five polymorphonuclear leucocytes were found in five high-power fields. Results. The sensitivity and specificity of the LE assay were 100% and 93.8%, respectively; the positive (PPV) and the negative (NPV) predictive values were 79.3% and 100%, respectively. The mean time between the collection of the sample and the result being known was 20.1 minutes (. sd. 4.4). The sensitivity and specificity of FS histology were 78.3% and 96.9%, respectively; the PPV and the NPV were 85.7% and 94.9%, respectively. The mean time between the collection of the sample and the result being known was 27.2 minutes (. sd. 6.9). Conclusion. The sensitivity of LE assay was higher, with similar specificity and diagnostic accuracy, compared with FS histology. The faster turnaround time, its ease of use, and low costs make LE assay a valuable alternative to FS histology. We now use it routinely for the intraoperative diagnosis of PJI. Cite this article: Bone Joint J 2019;101-B:372–377


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 2 | Pages 233 - 247
1 May 1957
McKenzie DS

1. Congenital defects of the extremities are described. Although the detailed anatomy is infinitely variable, a broad classification in relation to prosthetic management has been suggested. 2. Most patients with these deformities can be fitted with a prosthesis without major surgical intervention. With this they will have at least as good function as they would have after amputation. A plea is made for a conservative attitude in this respect. It is suggested that recourse to amputation should be confined to cases in which prosthetic equipment falls short of functional and cosmetic requirements, and that, when possible, it should be deferred until the child is old enough to share in the decision. 3. The prostheses applicable to the various types of deformity are briefly described. 4. The application of similar techniques to cases of acquired shortening is mentioned. 5. The incorporation of certain features of artificial arms in flail arm splints is discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 643 - 646
1 Jul 1990
Mulroy R Mankin H Harris W

We describe a patient in whom a total hip replacement had failed and who subsequently fractured her proximal femur. The prosthetic hip and the surrounding bone were excised and replaced by a matched pair of allograft components. She obtained seven years of pain free hip function before the graft showed radiographic signs of failure; it was then replaced by a new prosthetic hip


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 582 - 588
1 May 2019
Sidhu MS Cooper G Jenkins N Jeys L Parry M Stevenson JD

Aims

The aims of this study were to report the efficacy of revision surgery for patients with co-infective bacterial and fungal prosthetic joint infections (PJIs) presenting to a single institution, and to identify prognostic factors that would guide management.

Patients and Methods

A total of 1189 patients with a PJI were managed in our bone infection service between 2006 and 2015; 22 (1.85%) with co-infective bacterial and fungal PJI were included in the study. There were nine women and 13 men, with a mean age at the time of diagnosis of 64.5 years (47 to 83). Their mean BMI was 30.9 kg/m2 (24 to 42). We retrospectively reviewed the outcomes of these PJIs, after eight total hip arthroplasties and 14 total knee arthroplasties. The mean clinical follow-up was 4.1 years (1.4 to 8.8).


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1038 - 1043
1 Nov 1990
Radford W Amis A

We have assessed the biomechanical properties of a 'double-bundle' prosthetic ligament replacing the anterior cruciate in cadaver knees. We compared the results with those of single bundle 'over-the-top' and 'through-the-condyle' techniques, performing anterior drawer tests at 20 degrees and 90 degrees knee flexion. The over-the-top reconstruction gave better anteroposterior stability at 20 degrees, while the through-the-condyle repair was more stable at 90 degrees. The double-bundle reconstruction gave practically normal anterior stability at both 20 degrees and 90 degrees


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 818 - 821
1 Sep 1993
Mody B Howard L Harding M Parmar H Learmonth D

We treated 39 knees with chronic deficiency of the anterior cruciate ligament by reconstruction using the ABC carbon and polyester prosthetic ligament; 31 (79.5%) were reviewed at an average follow-up of 34 months. There had been four complete failures requiring revision. The remaining 27 were studied in detail. On the Lysholm rating, only 11 knees (41%) had good results with a score of over 76. The mean anterior drawer movement was reduced from 7.6 mm before operation to 5.8 mm at review. The mean difference from the opposite uninjured knee was 3.9 mm before operation, 1 mm (in 21 patients) at mean follow-up of 7.4 months and 2.5 mm (in 27 patients) at 34 months, indicating progressive loss of effect. In our opinion the results are unsatisfactory: we do not recommend the use of this prosthetic ligament


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 647 - 652
1 Aug 1986
Pring D Henderson R Rivett A Krausz T Coombs R Lavender J

To detect sepsis in the painful joint, autologous granulocytes labelled with indium-111 were used to scan 60 patients with 74 prosthetic joints. All 18 patients with confirmed sepsis had positive scans, that is, migration of granulocytes into the region of the prosthesis. Of the 22 sterile arthroplasties 20 had negative scans. In 34 cases there was good correlation between the clinical impression and the result of the scan. We suggest that indium granulocyte scintigraphy is a reliable method of detecting an infected prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 552 - 560
1 Nov 1978
Herberts P Almstrom C Caine K

A control system for a multifunctional hand prosthesis, which requires a minimum of training for the amputee, has been developed. The great advantage of the pattern recognition technique in making it possible to control as many as six prosthetic movements has prompted this study. The development of a complete miniaturised system has allowed a clinical trial on four patients. Two different tests have been employed to evaluate this system: an objective computer test and a test representing activities of daily living (ADL test). The computer test shows that a high rate of correct recognition is obtained immediately after the prosthesis is applied to the amputee. The ADL test shows that forearm rotation, and flexion and extension of the wrist are used in most activities, indicating that few compensatory movements are performed. It is suggested that this control system is feasible and that long periods of training are unnecessary


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 183 - 184
1 Mar 2001
Bruce ASW Kerry RM Norman P Stockley I

We report two cases of fungal infection of prosthetic joints which were successfully treated by the incorporation of fluconazole into polymethylmethacrylate beads inserted at the time of debridement


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 531 - 539
1 May 1998
Goodman SB Huie P Song Y Schurman D Maloney W Woolson S Sibley R

The tissues surrounding 65 cemented and 36 cementless total joint replacements undergoing revision were characterised for cell types by immunohistochemistry and for cytokine expression by in situ hybridisation. We identified three distinct groups of revised implants: loose implants with ballooning radiological osteolysis, loose implants without osteolysis, and well-fixed implants. In the cemented series, osteolysis was associated with increased numbers of macrophages (p = 0.0006), T-lymphocyte subgroups (p = 0.03) and IL-1 (p = 0.02) and IL-6 (p = 0.0001) expression, and in the cementless series with increased numbers of T-lymphocyte subgroups (p = 0.005) and increased TNFα expression (p = 0.04). For cemented implants, the histological, histochemical and cytokine profiles of the interface correlated with the clinical and radiological grade of loosening and osteolysis. Our findings suggest that there are different biological mechanisms of loosening and osteolysis for cemented and cementless implants. T-lymphocyte modulation of macrophage function may be an important interaction at prosthetic interfaces


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 816 - 819
1 Sep 1997
An YH Bradley J Powers DL Friedman RJ

We evaluated the effects of a serum protein coating on prosthetic infection in 29 adult male rabbits divided into three groups: control, albumin-coated and uncoated. We used 34 grit-blasted, commercially pure titanium implants. Eleven were coated with cross-linked albumin. All the implants were exposed to a suspension of Staphylococcus epidermidis before implantation. Our findings showed that albumin-coated implants had a much lower infection rate (27%) than the uncoated implants (62%). This may be a useful method of reducing the infection of prostheses


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 5 | Pages 586 - 589
1 Dec 1982
Cole W Klein R van Lith M Jarvis R

A programme for early mobilisation using a temporary prosthesis was evaluated in 17 children who had had an amputation above the knee for sarcomata. The temporary prosthesis had a performed adjustable polypropylene quadrilateral socket which was able to accommodate changes in the size of the stump during the first few months after amputation. The adjustable sockets were assembled onto wooden knee-shank-foot units or onto modular components covered with foam. The wooden units were better for routine use as more adjustment was possible between the socket and the knee and because they were more durable in active children. Prosthetic fitting usually took one hour and was carried out 10 days after the amputation to coincide with the start of the chemotherapy programme. The prosthesis was cosmetically acceptable, easy to use and provided a simple and economical way of rehabilitating the amputees and restoring their morale. After two to three months a new prosthesis with a laminated socket suspended by a waistband was supplied. The skin tolerated the closer fit of this socket and the small fluctuations in the size of the stump that occurred with each course of chemotherapy were easily accommodated by varying the thickness of the stump sock. A self-suspending laminated socket was provided after completion of the chemotherapy. The permanent sockets were assembled onto wooden components but the girls usually preferred the modular system covered with foam. The chemotherapy and rehabilitation programmes were successfully co-ordinated so that the children spent as little time as possible away from their normal activities


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1157 - 1161
1 Sep 2018
Brown TS Fehring KA Ollivier M Mabry TM Hanssen AD Abdel MP

Aims

Recurrent infection following two-stage revision total hip arthroplasty (THA) for prosthetic joint infection (PJI) is a devastating complication. The purpose of this study was to report the survival of repeat two-stage revision hip arthroplasty, describe complications, and identify risk factors for failure.

Patients and Methods

We retrospectively identified 19 hips (19 patients) that had undergone repeat two-stage revision THA for infection between 2000 to 2013. There were seven female patients (37%) and the mean age was 60 years (30 to 85). Survival free from revision was assessed via Kaplan–Meier analysis. The patients were classified according to the Musculoskeletal Infection Society (MSIS) system, and risk factors for failure were identified. Mean follow-up was four years (2 to 11).


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1176 - 1182
1 Sep 2017
Berger P Van Cauter M Driesen R Neyt J Cornu O Bellemans J

Aims

The purpose of this current multicentre study is to analyse the presence of alpha-defensin proteins in synovial fluid using the Synovasure lateral flow device and to determine its diagnostic reliability and accuracy compared with the prosthetic joint infection (PJI) criteria produced by the Musculoskeletal Infection Society (MSIS).

Patients and Methods

A cohort of 121 patients comprising 85 total knee arthroplasties and 36 total hip arthroplasties was prospectively evaluated between May 2015 and June 2016 in three different orthopaedic centres. The tests were performed on patients with a chronically painful prosthesis undergoing a joint aspiration in a diagnostic pathway or during revision surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 943 - 948
1 Jul 2006
Phillips JE Crane TP Noy M Elliott TSJ Grimer RJ

The Control of Infection Committee at a specialist orthopaedic hospital prospectively collected data on all episodes of bacteriologically-proven deep infection arising after primary hip and knee replacements over a 15-year period from 1987 to 2001.

There were 10 735 patients who underwent primary hip or knee replacement. In 34 of 5947 hip replacements (0.57%) and 41 of 4788 knee replacements (0.86%) a deep infection developed. The most common infecting micro-organism was coagulase-negative staphylococcus, followed by Staphylococcus aureus, enterococci and streptococci. Of the infecting organisms, 72% were sensitive to routine prophylactic antimicrobial agents.

Of the infections, 29% (22) arose in the first three months following surgery, 35% between three months and one year (26), and 36% (27) after one year. Most cases were detected early and treated aggressively, with eradication of the infection in 96% (72). There was no significant change in the infection rate or type of infecting micro-organism over the course of this study.

These results set a benchmark, and importantly emphasise that only 64% of peri-prosthetic infections arise within one year of surgery. These results also illustrate the advantages of conducting joint replacement surgery in the isolation of a specialist hospital.


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 4 | Pages 775 - 776
1 Nov 1971
Lamb DW


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 941 - 943
1 Nov 1998
Grigoris P Hamblen D


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 3 | Pages 652 - 654
1 Aug 1962
Vitali M

1. A case of essential osteolysis previously reported in this Journal is recalled briefly and its subsequent course is outlined.

2. A successful prosthesis is described which has enabled the patient to lead a relatively normal life.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 345 - 348
1 May 1996
Amis AA


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 281 - 281
1 Feb 2007
CHITRE AR SADIQ S


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 614 - 619
1 Jul 1998
Baksi DP

From 1984 to 1995, 68 ankylosed elbows and 11 which were unstable after trauma were replaced in India by Baksi sloppy hinge prostheses. The mean age of the patients was 28.6 years (17 to 70) and the mean follow-up 9.6 years (2 to 13.5).

Of the 68 ankylosed elbows, 59 (87%) regained a mean arc of painless movement of 88.5° (27 to 115). The mean improvement of supination was 24° and of pronation 16.5°. There were 54 good results (80%), eight fair and three poor. There were two complete failures due to infection, and one due to a broken humeral stem.

Of the 11 unstable elbows, the nine with good results had a mean arc of 125° (15 to 140) of painless stable movement, with a mean improvement in supination of 26° and of pronation of 19.5°. There was one fair result and one failure due to loosening with subsequent late infection.

There were significant complications in 14 cases with infection in seven and aseptic loosening in four. Patients with loosening or late removal of the prosthesis often retained reasonably stable elbow movement because periprosthetic fibrosis had connected the approximated bone ends, and muscle balance had been restored.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 312 - 316
1 Mar 1987
Thomas N Turner I Jones C

Four types of prosthetic replacement for the anterior cruciate ligament (carbon fibre, carbon fibre and Dacron composite, Dacron alone and bovine xenograft) were assessed at three, six and 12 months after implantation in the knees of New Zealand white rabbits. The synovium and both intra-articular and intra-osseous portions of the ligaments were examined macroscopically, by light microscopy and by scanning electron microscopy. All the knees showed mild synovitis, and there was no significant growth into the intra-articular part of any ligament. Carbon fibre and xenograft did not appear to be suitable materials in this animal model. The composite ligament showed short-term ingrowth of fibrous tissue only into the periphery of the sheath in its intra-osseous portion, whereas the Dacron ligament showed progressive fibrous tissue ingrowth with some bony incorporation of its outer fibres.


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 3 | Pages 469 - 471
1 Aug 1965
Nickel VL Waring W

Future devices will be more reliable, although more versatile and complex. They will require less attention and maintenance, but more skill when maintenance or repair is necessary. They will require less training of the patient before he can use them successfully and will be more immediately responsive to his wishes, giving smooth, integrated movements, varying with the intensity and direction of his effort.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1547 - 1547
1 Nov 2006
Laurence M


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 70 - 72
1 Jan 2002
Taggart T Kerry RM Norman P Stockley I

Although the incidence of infection associated with hip and knee prostheses is low, with the increasing number of arthroplasties being carried out, the total number of such cases is increasing. The pattern of infecting organisms after total joint arthroplasty has changed and gentamicin-resistant organisms are becoming increasingly common. In conjunction with surgical debridement, vancomycin added to a bone-cement carrier can be very effective in the treatment of infection caused by such organisms.

We report the results of its use in proven deep infection in 26 hip and seven knee arthroplasties. After a mean follow-up of 67 months, 32 patients remained clinically and radiologically free from infection. There was one recurrence and positive second-stage cultures of uncertain significance in three other patients. Vancomycin is potentially very useful in the management of deep infection after arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 191 - 194
1 Mar 1991
Thyne G Ferguson J


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 5 - 13
1 Jan 1996
Unwin PS Cannon SR Grimer RJ Kemp HBS Sneath RS Walker PS

We have made a retrospective study of 1001 custom-made prostheses used as replacements after surgery for bone tumours. There were 493 distal femoral, 263 proximal femoral and 245 proximal tibial prostheses. Aseptic loosening was shown to be the principal mode of failure of the implants, and 71 patients had revision for aseptic loosening of a cemented intramedullary stem.

The probability of a patient surviving aseptic loosening for 120 months was 93.8% for a proximal femoral replacement, 67.4% for a distal femoral prosthesis and 58% for a proximal tibial implant. In patients with distal femoral replacements the age of the patient at the time of operation and the percentage of bone resected were related to the risk of aseptic loosening. Young patients with distal femoral prostheses in whom a high percentage of the femur had been replaced had the poorest prognosis for survival without aseptic loosening. The percentage of bone removed had a significant effect in the proximal tibial replacement group, but the age of the patient did not. By contrast, neither the age nor the percentage of bone removed was a factor after proximal femoral replacement.

The significance of these findings is discussed in relation to mechanical factors.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 817 - 825
1 Aug 2024
Borukhov I Ismailidis P Esposito CI LiArno S Lyon J McEwen PJ

Aims. This study aimed to evaluate if total knee arthroplasty (TKA) femoral components aligned in either mechanical alignment (MA) or kinematic alignment (KA) are more biomimetic concerning trochlear sulcus orientation and restoration of trochlear height. Methods. Bone surfaces from 1,012 CT scans of non-arthritic femora were segmented using a modelling and analytics system. TKA femoral components (Triathlon; Stryker) were virtually implanted in both MA and KA. Trochlear sulcus orientation was assessed by measuring the distal trochlear sulcus angle (DTSA) in native femora and in KA and MA prosthetic femoral components. Trochlear anatomy restoration was evaluated by measuring the differences in medial, lateral, and sulcus trochlear height between native femora and KA and MA prosthetic femoral components. Results. Femoral components in both MA and KA alignments exhibited a more valgus DTSA compared to native femora. However, DTSA deviation from native was significantly less in KA than in MA (4.8° (SD 2.2°) vs 8.8° (SD 1.8°); p < 0.001). DTSA deviation from native orientation correlated positively with the mechanical lateral distal femoral angle (mLDFA) in KA and negatively in MA (r = 0.53, p < 0.001; r = -0.18, p < 0.001). Medial trochlear height was not restored with either MA or KA, with MA resulting in lower medial trochlear height than KA in the proximal 20% of the trochlea. Lateral and sulcus trochlear height was not restored with either alignment in the proximal 80% of the trochlea. At the terminal arc point, KA replicated sulcus and lateral trochlear height, while MA led to over-restoration. Conclusion. Femoral components aligned in KA demonstrated greater biomimetic qualities than those in MA regarding trochlear sulcus orientation and trochlear height restoration, particularly in valgus femora. Variability across knees was observed, warranting further research to evaluate the clinical implications of these findings. Cite this article: Bone Joint J 2024;106-B(8):817–825


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 923 - 930
1 May 2021
He R Wang Q Wang J Tang J Shen H Zhang X

Aims. As a proven and comprehensive molecular technique, metagenomic next-generation sequencing (mNGS) has shown its potential in the diagnosis of pathogens in patients with periprosthetic joint infection (PJI), using a single type of specimen. However, the optimal use of mNGS in the management of PJI has not been explored. In this study, we evaluated the diagnostic value of mNGS using three types of specimen with the aim of achieving a better choice of specimen for mNGS in these patients. Methods. In this prospective study, 177 specimens were collected from 59 revision arthroplasties, including periprosthetic tissues, synovial fluid, and prosthetic sonicate fluid. Each specimen was divided into two, one for mNGS and one for culture. The criteria of the Musculoskeletal Infection Society were used to define PJI (40 cases) and aseptic failure (19 cases). Results. The sensitivity and specificity of mNGS in the diagnosis of PJI were 95% and 94.7%, respectively, for all types of specimen. The sensitivity and specificity were 65% and 100%, respectively, for periprosthetic tissues, 87.5% and 94.7%, respectively, for synovial fluid, and 92.5% and 94.7%, respectively, for prosthetic sonicate fluid. The mNGS of prosthetic sonicate fluid outperformed that for other types of specimen in the rates of detection of pathogens (84.6%), sequencing reads (> ten-fold) and the rate of genome coverage (> five-fold). Conclusion. mNGS could serve as an accurate diagnostic tool in the detection of pathogens in patients with a PJI using three types of specimen. Due to its superior perfomance in identifying a pathogen, mNGS of prosthetic sonicate fluid provides the most value and may partly replace traditional tests such as bacteriological culture in these patients. Cite this article: Bone Joint J 2021;103-B(5):923–930


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 430 - 439
1 Mar 2021
Geary M Gaston RG Loeffler B

Upper limb amputations, ranging from transhumeral to partial hand, can be devastating for patients, their families, and society. Modern paradigm shifts have focused on reconstructive options after upper extremity limb loss, rather than considering the amputation an ablative procedure. Surgical advancements such as targeted muscle reinnervation and regenerative peripheral nerve interface, in combination with technological development of modern prosthetics, have expanded options for patients after amputation. In the near future, advances such as osseointegration, implantable myoelectric sensors, and implantable nerve cuffs may become more widely used and may expand the options for prosthetic integration, myoelectric signal detection, and restoration of sensation. This review summarizes the current advancements in surgical techniques and prosthetics for upper limb amputees. Cite this article: Bone Joint J 2021;103-B(3):430–439



The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 935 - 941
1 Sep 2024
Ailaney N Guirguis PG Ginnetti JG Balkissoon R Myers TG Ramirez G Thirukumaran CP Ricciardi BF

Aims. The purpose of this study was to determine the association between prior sleeve gastrectomy in patients undergoing primary total hip and knee arthroplasty, and 90-day complications, incidence of revision arthroplasty, and patient-reported outcome scores at final follow-up. Methods. This is a retrospective, single-centre analysis. Patients undergoing primary hip or knee arthroplasty with a prior sleeve gastrectomy were eligible for inclusion (n = 80 patients). A morbidly obese control group was established from the same institutional registry using a 1:2 match, for cases:controls with arthroplasty based on propensity score using age, sex, pre-sleeve gastrectomy BMI, Current Procedural Terminology code to identify anatomical location, and presurgical haemoglobin A1C. Outcomes included 90-day complications, incidence of revision arthroplasty, and patient-reported outcome scores at final follow-up. Multivariable logistic regressions evaluated associations of underlying preoperative demographic and treatment characteristics with outcomes. Results. Complications within 90 days of surgery were increased in the sleeve gastrectomy group relative to the obese control group after controlling for underlying preoperative demographic characteristics (odds ratio (OR) 4.00 (95% CI 1.14 to 13.9); p = 0.030). Postoperative revisions were similar in the sleeve gastrectomy group relative to the obese control group after controlling for underlying preoperative demographic characteristics (OR 17.8 (95% CI 0.64 to 494.3); p = 0.090). Patient-Reported Outcomes Measurement Information System (PROMIS) depression decreased by a greater amount from pre- to postoperative in the obese controls relative to the sleeve gastrectomy group (OR 4.04 (95% CI 0.06 to 8.02); p = 0.047). PROMIS pain interference and physical function change from pre- to postoperative was not associated with sleeve gastrectomy status. Conclusion. We found a higher rate of complications at 90 days in patients who underwent sleeve gastrectomy prior to primary hip or knee arthroplasty relative to a matched, obese control population. Prosthetic revision rates were similar between the two groups, while improvements in PROMIS depression scores were larger in the obese cohort. This study suggests that sleeve gastrectomy to achieve preoperative weight loss prior to arthroplasty surgery may not mitigate early complication risks in obese patient populations. Cite this article: Bone Joint J 2024;106-B(9):935–941


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1405 - 1413
1 Aug 2021
Ogura K Fujiwara T Morris CD Boland PJ Healey JH

Aims. Rotating-hinge knee prostheses are commonly used to reconstruct the distal femur after resection of a tumour, despite the projected long-term burden of reoperation due to complications. Few studies have examined the factors that influence their failure and none, to our knowledge, have used competing risk models to do so. The purpose of this study was to determine the risk factors for failure of a rotating-hinge knee distal femoral arthroplasty using the Fine-Gray competing risk model. Methods. We retrospectively reviewed 209 consecutive patients who, between 1991 and 2016, had undergone resection of the distal femur for tumour and reconstruction using a rotating-hinge knee prosthesis. The study endpoint was failure of the prosthesis, defined as removal of the femoral component, the tibial component, or the bone-implant fixation; major revision (exchange of the femoral component, tibial component, or the bone-implant fixation); or amputation. Results. Multivariate Fine-Gray regression analyses revealed different hazards for each Henderson failure mode: percentage of femoral resection (p = 0.001) and extent of quadriceps muscle resection (p = 0.005) for overall prosthetic failure; extent of quadriceps muscle resection (p = 0.002) and fixation of femoral component (p = 0.011) for type 2 failure (aseptic loosening); age (p = 0.009) and percentage of femoral resection (p = 0.019) for type 3 failure (mechanical failure); and type of joint resection (p = 0.037) for type 4 (infection) were independent predictors. A bone stem ratio of > 2.5 reliably predicted aseptic loosening. Conclusion. We identified independent risk factors for overall and cause-specific prosthetic failure after rotating-hinge knee distal femoral arthroplasty using a competing risk Fine-Gray model. A bone stem ratio > 2.5 reliably predicts aseptic loosening. An accurate knowledge of the risks of distal femoral arthroplasty after resection for tumour assists surgical planning and managing patient expectations. Cite this article: Bone Joint J 2021;103-B(8):1405–1413


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 9 - 16
1 Jul 2021
Hadden WJ Ibrahim M Taha M Ure K Liu Y Paish ADM Holdsworth DW Abdelbary H

Aims. The aims of this study were to develop an in vivo model of periprosthetic joint infection (PJI) in cemented hip hemiarthroplasty, and to monitor infection and biofilm formation in real-time. Methods. Sprague-Dawley rats underwent cemented hip hemiarthroplasty via the posterior approach with pre- and postoperative gait assessments. Infection with Staphylococcus aureus Xen36 was monitored with in vivo photoluminescent imaging in real-time. Pre- and postoperative gait analyses were performed and compared. Postmortem micro (m) CT was used to assess implant integration; field emission scanning electron microscopy (FE-SEM) was used to assess biofilm formation on prosthetic surfaces. Results. All animals tolerated surgery well, with preservation of gait mechanics and weightbearing in control individuals. Postoperative in vivo imaging demonstrated predictable evolution of infection with logarithmic signal decay coinciding with abscess formation. Postmortem mCT qualitative volumetric analysis showed high contact area and both cement-bone and cement-implant interdigitation. FE-SEM revealed biofilm formation on the prosthetic head. Conclusion. This study demonstrates the utility of a new, high-fidelity model of in vivo PJI using cemented hip hemiarthroplasty in rats. Inoculation with bioluminescent bacteria allows for non-invasive, real-time monitoring of infection. Cite this article: Bone Joint J 2021;103-B(7 Supple B):9–16


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1021 - 1030
1 Sep 2024
Oto J Herranz R Fuertes M Plana E Verger P Baixauli F Amaya JV Medina P

Aims. Bacterial infection activates neutrophils to release neutrophil extracellular traps (NETs) in bacterial biofilms of periprosthetic joint infections (PJIs). The aim of this study was to evaluate the increase in NET activation and release (NETosis) and haemostasis markers in the plasma of patients with PJI, to evaluate whether such plasma induces the activation of neutrophils, to ascertain whether increased NETosis is also mediated by reduced DNaseI activity, to explore novel therapeutic interventions for NETosis in PJI in vitro, and to evaluate the potential diagnostic use of these markers. Methods. We prospectively recruited 107 patients in the preoperative period of prosthetic surgery, 71 with a suspicion of PJI and 36 who underwent arthroplasty for non-septic indications as controls, and obtained citrated plasma. PJI was confirmed in 50 patients. We measured NET markers, inflammation markers, DNaseI activity, haemostatic markers, and the thrombin generation test (TGT). We analyzed the ability of plasma from confirmed PJI and controls to induce NETosis and to degrade in vitro-generated NETs, and explored the therapeutic restoration of the impairment to degrade NETs of PJI plasma with recombinant human DNaseI. Finally, we assessed the contribution of these markers to the diagnosis of PJI. Results. Patients with confirmed PJI had significantly increased levels of NET markers (cfDNA (p < 0.001), calprotectin (p < 0.001), and neutrophil elastase (p = 0.022)) and inflammation markers (IL-6; p < 0.001) in plasma. Moreover, the plasma of patients with PJI induced significantly more neutrophil activation than the plasma of the controls (p < 0.001) independently of tumour necrosis factor alpha. Patients with PJI also had a reduced DNaseI activity in plasma (p < 0.001), leading to a significantly impaired degradation of NETs (p < 0.001). This could be therapeutically restored with recombinant human DNaseI to the level in the controls. We developed a model to improve the diagnosis of PJI with cfDNA, calprotectin, and the start tail of TGT as predictors, though cfDNA alone achieved a good prediction and is simpler to measure. Conclusion. We confirmed that patients with PJI have an increased level of NETosis in plasma. Their plasma both induced NET release and had an impaired ability to degrade NETs mediated by a reduced DNaseI activity. This can be therapeutically restored in vitro with the approved Dornase alfa, Pulmozyme, which may allow novel methods of treatment. A combination of NETs and haemostatic biomarkers could improve the diagnosis of PJI, especially those patients in whom this diagnosis is uncertain. Cite this article: Bone Joint J 2024;106-B(9):1021–1030


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1206 - 1215
1 Nov 2024
Fontalis A Buchalter D Mancino F Shen T Sculco PK Mayman D Haddad FS Vigdorchik J

Understanding spinopelvic mechanics is important for the success of total hip arthroplasty (THA). Despite significant advancements in appreciating spinopelvic balance, numerous challenges remain. It is crucial to recognize the individual variability and postoperative changes in spinopelvic parameters and their consequential impact on prosthetic component positioning to mitigate the risk of dislocation and enhance postoperative outcomes. This review describes the integration of advanced diagnostic approaches, enhanced technology, implant considerations, and surgical planning, all tailored to the unique anatomy and biomechanics of each patient. It underscores the importance of accurately predicting postoperative spinopelvic mechanics, selecting suitable imaging techniques, establishing a consistent nomenclature for spinopelvic stiffness, and considering implant-specific strategies. Furthermore, it highlights the potential of artificial intelligence to personalize care. Cite this article: Bone Joint J 2024;106-B(11):1206–1215


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 183 - 188
1 Jan 2022
van Sloten M Gómez-Junyent J Ferry T Rossi N Petersdorf S Lange J Corona P Araújo Abreu M Borens O Zlatian O Soundarrajan D Rajasekaran S Wouthuyzen-Bakker M

Aims. The aim of this study was to analyze the prevalence of culture-negative periprosthetic joint infections (PJIs) when adequate methods of culture are used, and to evaluate the outcome in patients who were treated with antibiotics for a culture-negative PJI compared with those in whom antibiotics were withheld. Methods. A multicentre observational study was undertaken: 1,553 acute and 1,556 chronic PJIs, diagnosed between 2013 and 2018, were retrospectively analyzed. Culture-negative PJIs were diagnosed according to the Muskuloskeletal Infection Society (MSIS), International Consensus Meeting (ICM), and European Bone and Joint Society (EBJIS) definitions. The primary outcome was recurrent infection, and the secondary outcome was removal of the prosthetic components for any indication, both during a follow-up period of two years. Results. None of the acute PJIs and 70 of the chronic PJIs (4.7%) were culture-negative; a total of 36 culture-negative PJIs (51%) were treated with antibiotics, particularly those with histological signs of infection. After two years of follow-up, no recurrent infections occurred in patients in whom antibiotics were withheld. The requirement for removal of the components for any indication during follow-up was not significantly different in those who received antibiotics compared with those in whom antibiotics were withheld (7.1% vs 2.9%; p = 0.431). Conclusion. When adequate methods of culture are used, the incidence of culture-negative PJIs is low. In patients with culture-negative PJI, antibiotic treatment can probably be withheld if there are no histological signs of infection. In all other patients, diagnostic efforts should be made to identify the causative microorganism by means of serology or molecular techniques. Cite this article: Bone Joint J 2022;104-B(1):183–188


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1271 - 1278
1 Dec 2023
Rehman Y Korsvold AM Lerdal A Aamodt A

Aims. This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS). Methods. Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed. Results. Patients reported similar levels of pain, function, satisfaction, and general health regardless of the prosthetic design they received. Mean maximal flexion (129° (95% confidence interval (CI) 127° to 131°) was greater in the PS group than in the CR (120° (95% CI 121° to 124°)) and AS groups (122° (95% CI 120° to 124°)). Conclusion. Despite differences in design and constraint, CR, AS, and PS designs from a single TKA system resulted in no differences in patient-reported outcomes at two-year follow-up. PS patients had statistically better ROM, but the clinical significance of this finding is unclear. Cite this article: Bone Joint J 2023;105-B(12):1271–1278


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 115 - 120
1 Mar 2024
Ricotti RG Flevas DA Sokrab R Vigdorchik JM Mayman DJ Jerabek SA Sculco TP Sculco PK

Aims. Periprosthetic femoral fracture (PPF) is a major complication following total hip arthroplasty (THA). Uncemented femoral components are widely preferred in primary THA, but are associated with higher PPF risk than cemented components. Collared components have reduced PPF rates following uncemented primary THA compared to collarless components, while maintaining similar prosthetic designs. The purpose of this study was to analyze PPF rate between collarless and collared component designs in a consecutive cohort of posterior approach THAs performed by two high-volume surgeons. Methods. This retrospective series included 1,888 uncemented primary THAs using the posterior approach performed by two surgeons (PKS, JMV) from January 2016 to December 2022. Both surgeons switched from collarless to collared components in mid-2020, which was the only change in surgical practice. Data related to component design, PPF rate, and requirement for revision surgery were collected. A total of 1,123 patients (59.5%) received a collarless femoral component and 765 (40.5%) received a collared component. PPFs were identified using medical records and radiological imaging. Fracture rates between collared and collarless components were analyzed. Power analysis confirmed 80% power of the sample to detect a significant difference in PPF rates, and a Fisher’s exact test was performed to determine an association between collared and collarless component use on PPF rates. Results. Overall, 17 PPFs occurred (0.9%). There were 16 fractures out of 1,123 collarless femoral components (1.42%) and one fracture out of 765 collared components (0.13%; p = 0.002). The majority of fractures (n = 14; 82.4%) occurred within 90 days of primary THA. There were ten reoperations for PPF with collarless components (0.89%) and one reoperation with a collared component (0.13%; p = 0.034). Conclusion. Collared femoral components were associated with significant decreases in PPF rate and reoperation rate for PPF compared to collarless components in uncemented primary THA. Future studies should investigate whether new-generation collared components reduce PPF rates with longer-term follow-up. Cite this article: Bone Joint J 2024;106-B(3 Supple A):115–120


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 34 - 44
1 Jan 2022
Beckers L Dandois F Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims. Higher osteoblastic bone activity is expected in aseptic loosening and painful unicompartmental knee arthroplasty (UKA). However, insights into normal bone activity patterns after medial UKAs are lacking. The aim of this study was to identify the evolution in bone activity pattern in well-functioning medial mobile-bearing UKAs. Methods. In total, 34 patients (13 female, 21 male; mean age 62 years (41 to 79); BMI 29.7 kg/m. 2. (23.6 to 42.1)) with 38 medial Oxford partial UKAs (20 left, 18 right; 19 cementless, 14 cemented, and five hybrid) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively, and at one and two years postoperatively. Changes in mean osteoblastic activity were investigated using a tracer localization scheme with volumes of interest (VOIs), reported by normalized mean tracer values. A SPECT/CT registration platform additionally explored cortical tracer evolution in zones of interest identified by previous experimental research. Results. Significant reduction of tracer activity from the preoperative situation was found in femoral and anteromedial tibial VOIs adjacent to the UKA components. Temporarily increased osteoblastic bone activity was observed in VOIs comprising the UKA keel structure at one year postoperatively compared to the preoperative activity. Persistent higher tracer uptake was found in the posterior tibial cortex at final follow-up. Multivariate analysis showed no statistical difference in osteoblastic bone activity underneath cemented or cementless components. Conclusion. Well-functioning medial mobile-bearing UKAs showed distinct changes in patterns of normalized bone tracer activity in the different VOIs adjacent to the prosthetic components, regardless of their type of fixation. Compared to the preoperative situation, persistent high bone activity was found underneath the keel and the posterior tibial cortex at final follow-up, with significant reduced activity only being identified in femoral and anteromedial tibial VOIs. Cite this article: Bone Joint J 2022;104-B(1):34–44


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 101 - 106
1 Jun 2020
Shah RF Bini SA Martinez AM Pedoia V Vail TP

Aims. The aim of this study was to evaluate the ability of a machine-learning algorithm to diagnose prosthetic loosening from preoperative radiographs and to investigate the inputs that might improve its performance. Methods. A group of 697 patients underwent a first-time revision of a total hip (THA) or total knee arthroplasty (TKA) at our institution between 2012 and 2018. Preoperative anteroposterior (AP) and lateral radiographs, and historical and comorbidity information were collected from their electronic records. Each patient was defined as having loose or fixed components based on the operation notes. We trained a series of convolutional neural network (CNN) models to predict a diagnosis of loosening at the time of surgery from the preoperative radiographs. We then added historical data about the patients to the best performing model to create a final model and tested it on an independent dataset. Results. The convolutional neural network we built performed well when detecting loosening from radiographs alone. The first model built de novo with only the radiological image as input had an accuracy of 70%. The final model, which was built by fine-tuning a publicly available model named DenseNet, combining the AP and lateral radiographs, and incorporating information from the patient’s history, had an accuracy, sensitivity, and specificity of 88.3%, 70.2%, and 95.6% on the independent test dataset. It performed better for cases of revision THA with an accuracy of 90.1%, than for cases of revision TKA with an accuracy of 85.8%. Conclusion. This study showed that machine learning can detect prosthetic loosening from radiographs. Its accuracy is enhanced when using highly trained public algorithms, and when adding clinical data to the algorithm. While this algorithm may not be sufficient in its present state of development as a standalone metric of loosening, it is currently a useful augment for clinical decision making. Cite this article: Bone Joint J 2020;102-B(6 Supple A):101–106


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 482 - 491
1 May 2024
Davies A Sabharwal S Liddle AD Zamora Talaya MB Rangan A Reilly P

Aims. Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods. NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation. Results. A total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure. Conclusion. The rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface. Cite this article: Bone Joint J 2024;106-B(5):482–491


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 55 - 63
1 Jan 2020
Hagberg K Ghassemi Jahani S Kulbacka-Ortiz K Thomsen P Malchau H Reinholdt C

Aims. The aim of this study was to describe implant and patient-reported outcome in patients with a unilateral transfemoral amputation (TFA) treated with a bone-anchored, transcutaneous prosthesis. Methods. In this cohort study, all patients with a unilateral TFA treated with the Osseointegrated Prostheses for the Rehabilitation of Amputees (OPRA) implant system in Sahlgrenska University Hospital, Gothenburg, Sweden, between January 1999 and December 2017 were included. The cohort comprised 111 patients (78 male (70%)), with a mean age 45 years (17 to 70). The main reason for amputation was trauma in 75 (68%) and tumours in 23 (21%). Patients answered the Questionnaire for Persons with Transfemoral Amputation (Q-TFA) before treatment and at two, five, seven, ten, and 15 years’ follow-up. A prosthetic activity grade was assigned to each patient at each timepoint. All mechanical complications, defined as fracture, bending, or wear to any part of the implant system resulting in removal or change, were recorded. Results. The Q-TFA scores at two, five, seven, and ten years showed significantly more prosthetic use, better mobility, fewer problems, and an improved global situation, compared with baseline. The survival rate of the osseointegrated implant part (the fixture) was 89% and 72% after seven and 15 years, respectively. A total of 61 patients (55%) had mechanical complications (mean 3.3 (SD 5.76)), resulting in exchange of the percutaneous implant parts. There was a positive relationship between a higher activity grade and the number of mechanical complications. Conclusion. Compared with before treatment, the patient-reported outcome was significantly better and remained so over time. Although osseointegration and the ability to transfer loads over a 15-year period have been demonstrated, a large number of mechanical failures in the external implant parts were found. Since these were related to higher activity, restrictions in activity and improvements to the mechanical properties of the implant system are required. Cite this article: Bone Joint J 2020;102-B(1):55–63


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 162 - 169
1 Feb 2020
Hoellwarth JS Tetsworth K Kendrew J Kang NV van Waes O Al-Maawi Q Roberts C Al Muderis M

Aims. Osseointegrated prosthetic limbs allow better mobility than socket-mounted prosthetics for lower limb amputees. Fractures, however, can occur in the residual limb, but they have rarely been reported. Approximately 2% to 3% of amputees with socket-mounted prostheses may fracture within five years. This is the first study which directly addresses the risks and management of periprosthetic osseointegration fractures in amputees. Methods. A retrospective review identified 518 osseointegration procedures which were undertaken in 458 patients between 2010 and 2018 for whom complete medical records were available. Potential risk factors including time since amputation, age at osseointegration, bone density, weight, uni/bilateral implantation and sex were evaluated with multiple logistic regression. The mechanism of injury, technique and implant that was used for fixation of the fracture, pre-osseointegration and post fracture mobility (assessed using the K-level) and the time that the prosthesis was worn for in hours/day were also assessed. Results. There were 22 periprosthetic fractures; they occurred exclusively in the femur: two in the femoral neck, 14 intertrochanteric and six subtrochanteric, representing 4.2% of 518 osseointegration operations and 6.3% of 347 femoral implants. The vast majority (19/22, 86.4%) occurred within 2 cm of the proximal tip of the implant and after a fall. No fractures occurred spontaneously. Fixation most commonly involved dynamic hip screws (10) and reconstruction plates (9). No osseointegration implants required removal, the K-level was not reduced after fixation of the fracture in any patient, and all retained a K-level of ≥ 2. All fractures united, 21 out of 22 patients (95.5%) wear their osseointegration-mounted prosthetic limb longer daily than when using a socket, with 18 out of 22 (81.8%) reporting using it for ≥ 16 hours daily. Regression analysis identified a 3.89-fold increased risk of fracture for females (p = 0.007) and a 1.02-fold increased risk of fracture per kg above a mean of 80.4 kg (p = 0.046). No increased risk was identified for bilateral implants (p = 0.083), time from amputation to osseointegration (p = 0.974), age at osseointegration (p = 0.331), or bone density (g/cm2, p = 0.560; T-score, p = 0.247; Z-score, p = 0.312). Conclusion. The risks and sequelae of periprosthetic fracture after press-fit osseointegration for amputation should not deter patients or clinicians from considering this procedure. Females and heavier patients are likely to have an increased risk of fracture. Age, years since amputation, and bone density do not appear influential. Cite this article: Bone Joint J 2020;102-B(2):162–169


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 530 - 535
1 Mar 2021
Giannicola G Castagna V Villani C Gumina S Scacchi M

Aims. It has been hypothesized that proximal radial neck resorption (PRNR) following press-fit radial head arthroplasty (RHA) is due to stress-shielding. We compared two different press-fit stems by means of radiographs to investigate whether the shape and size of the stems are correlated with the degree of PRNR. Methods. The radiographs of 52 RHAs were analyzed both at 14 days postoperatively and after two years. A cylindrical stem and a conical stem were implanted in 22 patients (group 1) and 30 patients (group 2), respectively. The PRNR was measured in the four quadrants of the radial neck and the degree of stem filling was calculated by analyzing the ratio between the prosthetic stem diameter (PSD) and the medullary canal diameter (MCD) at the proximal portion of the stem (level A), halfway along the stem length (level B), and distally at the stem tip (level C). Results. Overall, 50 of the 52 patients displayed PRNR. The mean PRNR observed was 3.9 mm (0 to 7.4). The degree of endomedullary stem filling at levels A, B, and C was 96%, 90%, and 68% in group 1, and 96%, 72%, and 57%, in group 2, with differences being significant at levels B (p < 0.001) and C (p < 0.001). No significant correlations emerged between the severity of PRNR and the three stem/canal ratios either within each group or between the groups. Conclusion. PRNR in press-fit RHA appears to be independent of the shape and size of the stems. Other causes besides stem design should be investigated to explain completely this phenomenon. Cite this article: Bone Joint J 2021;103-B(3):530–535


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 736 - 743
1 Jun 2020
Svensson K Rolfson O Mohaddes M Malchau H Erichsen Andersson A

Aims. To investigate the experience and emotional impact of prosthetic joint infection (PJI) on orthopaedic surgeons and identify holistic strategies to improve the management of PJI and protect surgeons’ wellbeing. Methods. In total, 18 prosthetic joint surgeons in Sweden were recruited using a purposive sampling strategy. Content analysis was performed on transcripts of individual in-person interviews conducted between December 2017 and February 2018. Results. PJI had a negative emotional impact on Swedish surgeons. Many felt guilt, stress, and a sense of failure, and several aspects of PJI management were associated with psychosocial challenges. Peer support was reported as the most important coping strategy as was collaborating with infectious disease specialists. Conclusion. Our study affirms that there is a negative emotional impact of PJI on surgeons which can be minimized by improved peer support and working in multidisciplinary teams. Based on the surgeons’ experiences we have identified desired improvements that may facilitate the management of PJI. These may also be applicable within other surgical specialties dealing with postoperative infections, but need to be evaluated for their efficacy. Cite this article: Bone Joint J 2020;102-B(6):736–743


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 894 - 903
1 Jul 2017
Bonnin MP Saffarini M Nover L van der Maas J Haeberle C Hannink G Victor J

Aims. The morphometry of the distal femur was largely studied to improve bone-implant fit in total knee arthroplasty (TKA), but little is known about the asymmetry of the posterior condyles. This study aimed to investigate the dimensions of the posterior condyles and the influence of externally rotating the femoral component on potential prosthetic overhang or under-coverage. Patients and Methods. We analysed the shape of 110 arthritic knees at the time of primary TKA using pre-operative CT scans. The height and width of each condyle were measured at the posterior femoral cut in neutral position, and in 3º and 5º of external rotation, using both central and medial referencing systems. We compared the morphological characteristics with those of 14 TKA models. Results. In the neutral position, the dimensions of the condyles were nearly equal. Externally rotating the femoral cut by 3º and 5º with ‘central referencing’ induced width asymmetry >  3 mm in 23 (21%) and 33 (30%) knees respectively, while with ‘medial referencing’ it induced width asymmetry > 3 mm in 43 (39%) and 75 (68%) knees respectively. The asymmetries induced by rotations were not associated with gender, aetiology or varus-valgus alignment. Conclusion. External rotation may amplify the asymmetry between the medial and lateral condyles, and exacerbate prosthetic overhang, particularly in the superolateral zone. ‘Central referencing’ guides result in less potential prosthetic overhang than ‘medial referencing’ guides. Cite this article: Bone Joint J 2017;99-B:894–903


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 553 - 561
1 Mar 2021
Smolle MA Leithner A Kapper M Demmer G Trost C Bergovec M Windhager R Hobusch GM

Aims. The aims of the study were to analyze differences in surgical and oncological outcomes, as well as quality of life (QoL) and function in patients with ankle sarcomas undergoing three forms of surgical treatment, minor or major limb salvage surgery (LSS), or amputation. Methods. A total of 69 patients with ankle sarcomas, treated between 1981 and 2017 at two tumour centres, were retrospectively reviewed (mean age at surgery: 46.3 years (SD 22.0); 31 females (45%)). Among these 69 patients 25 were analyzed prospectively (mean age at latest follow-up: 61.2 years (SD 20.7); 11 females (44%)), and assessed for mobility using the Prosthetic Limb Users Survey of Mobility (PLUS-M; for amputees only), the Toronto Extremity Salvage Score (TESS), and the University of California, Los Angeles (UCLA) Activity Score. Individual QoL was evaluated in these 25 patients using the five-level EuroQol five-dimension (EQ-5D-5L) and Fragebogen zur Lebenszufriedenheit/Questions on Life Satisfaction (FLZ). Results. Of the total number of patients in the study, 22 (32%) underwent minor LSS and 22 (32%) underwent major LSS; 25 underwent primary amputation (36%). Complications developed in 26 (38%) patients, and were more common in those with major or minor LSS in comparison to amputation (59% vs 36% vs 20%; p = 0.022). A time-dependent trend towards higher complication risk following any LSS was present (relative risk: 0.204; 95% confidence interval (CI) 0.026 to 1.614; p = 0.095). In the prospective cohort, mean TESS was higher following minor LSS in comparison to amputation (91.0 vs 67.3; p = 0.006), while there was no statistically significant difference between major LSS and amputation (81.6 vs 67.3; p = 0.099). There was no difference in mean UCLA (p = 0.334) between the three groups (p = 0.334). None of the items in FLZ or EQ-5D-5L were different between the three groups (all p > 0.05), except for FLZ item “self-relation”, being lower in amputees. Conclusion. Complications are common following LSS for ankle sarcomas. QoL is comparable between patients with LSS or amputation, despite better mobility scores for patients following minor LSS. We conclude that these results allow a decision for amputation to be made more easily in patients particularly where the principles of oncological surgery would otherwise be at risk. Cite this article: Bone Joint J 2021;103-B(3):553–561