Advertisement for orthosearch.org.uk
Results 1 - 50 of 116
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 879 - 883
1 Sep 2024
Kayani B Staats K Haddad FS


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1060 - 1069
1 Oct 2023
Holleyman RJ Jameson SS Reed M Meek RMD Khanduja V Hamer A Judge A Board T

Aims. This study describes the variation in the annual volumes of revision hip arthroplasty (RHA) undertaken by consultant surgeons nationally, and the rate of accrual of RHA and corresponding primary hip arthroplasty (PHA) volume for new consultants entering practice. Methods. National Joint Registry (NJR) data for England, Wales, Northern Ireland, and the Isle of Man were received for 84,816 RHAs and 818,979 PHAs recorded between April 2011 and December 2019. RHA data comprised all revision procedures, including first-time revisions of PHA and any subsequent re-revisions recorded in public and private healthcare organizations. Annual procedure volumes undertaken by the responsible consultant surgeon in the 12 months prior to every index procedure were determined. We identified a cohort of ‘new’ HA consultants who commenced practice from 2012 and describe their rate of accrual of PHA and RHA experience. Results. The median annual consultant RHA volume, averaged across all cases, was 21 (interquartile range (IQR) 11 to 34; range 0 to 181). Of 1,695 consultants submitting RHA cases within the study period, the top 20% of surgeons by annual volume performed 74.2% of total RHA case volume. More than half of all consultants who had ever undertaken a RHA maintained an annual volume of just one or fewer RHA, however, collectively contributed less than 3% of the total RHA case volume. Consultant PHA and RHA volumes were positively correlated. Lower-volume surgeons were more likely to undertake RHA for urgent indications (such as infection) as a proportion of their practice, and to do so on weekends and public holidays. Conclusion. The majority of RHAs were undertaken by higher-volume surgeons. There was considerable variation in RHA volumes by indication, day of the week, and between consultants nationally. The rate of accrual of RHA experience by new consultants is low, and has important implications for establishing an experienced RHA consultant workforce. Cite this article: Bone Joint J 2023;105-B(10):1060–1069


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1050 - 1058
1 Oct 2024
Holleyman RJ Jameson SS Meek RMD Khanduja V Reed MR Judge A Board TN

Aims. This study evaluates the association between consultant and hospital volume and the risk of re-revision and 90-day mortality following first-time revision of primary hip arthroplasty for aseptic loosening. Methods. We conducted a cohort study of first-time, single-stage revision hip arthroplasties (RHAs) performed for aseptic loosening and recorded in the National Joint Registry (NJR) data for England, Wales, Northern Ireland, and the Isle of Man between 2003 and 2019. Patient identifiers were used to link records to national mortality data, and to NJR data to identify subsequent re-revision procedures. Multivariable Cox proportional hazard models with restricted cubic splines were used to define associations between volume and outcome. Results. Among 12,961 RHAs there were 513 re-revisions within two years, and 95 deaths within 90 days of surgery. The risk of re-revision was highest for a consultant’s first RHA (hazard ratio (HR) 1.56 (95% CI 1.15 to 2.12)) and remained significantly elevated for their first 24 cases (HR 1.26 (95% CI 1.00 to 1.58)). Annual consultant volumes of five/year were associated with an almost 30% greater risk of re-revision (HR 1.28 (95% CI 1.00 to 1.64)) and 80% greater risk of 90-day mortality (HR 1.81 (95% CI 1.02 to 3.21)) compared to volumes of 20/year. RHAs performed at hospitals which had cumulatively undertaken fewer than 167 RHAs were at up to 70% greater risk of re-revision (HR 1.70 (95% CI 1.12 to 2.59)), and those having undertaken fewer than 307 RHAs were at up to three times greater risk of 90-day mortality (HR 3.05 (95% CI 1.19 to 7.82)). Conclusion. This study found a significantly higher risk of re-revision and early postoperative mortality following first-time single-stage RHA for aseptic loosening when performed by lower-volume consultants and at lower-volume institutions, supporting the move towards the centralization of such cases towards higher-volume units and surgeons. Cite this article: Bone Joint J 2024;106-B(10):1050–1058


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1602 - 1609
1 Dec 2011
Malviya A Ramaskandhan JR Bowman R Hashmi M Holland JP Kometa S Lingard E

The aim of this study was to investigate the possible benefit of large-head metal-on-metal bearing on a stem for primary hip replacement compared with a 28 mm diameter conventional metal-on-polyethylene bearing in a prospective randomised controlled trial. We investigated cemented stem behaviour between these two different bearings using Einzel-Bild-Röntgen-Analyse, clinical and patient reported measures (Harris hip score, Western Ontario and McMaster Universities osteoarthritis index, Short Form-36 and satisfaction) and whole blood metal ion levels at two years. A power study indicated that 50 hips were needed in each group to detect subsidence of > 5 mm at two years with a p-value of < 0.05. . Significant improvement (p < 0.001) was found in the mean clinical and patient reported outcomes at two years for both groups. Comparison of outcomes between the groups at two years showed no statistically significant difference for mean stem migration, clinical and patient reported outcomes; except overall patient satisfaction which was higher for metal-on-metal group (p = 0.05). Metal ion levels were raised above the Medicines and Healthcare products Regulatory Agency advised safety level (7 µg per litre) in 20% of the metal-on-metal group and in one patient in metal-on-polyethylene group (who had a metal-on-metal implant on the contralateral side). Two patients in the metal-on-metal group were revised, one for pseudotumour and one for peri-prosthetic fracture. . Use of large modular heads is associated with a risk of raised whole blood metal ion levels despite using a proven bearing from resurfacing. The head-neck junction or excess stem micromotion are possibly the weak links warranting further research


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 562 - 569
1 May 2008
Daniel J Pradhan A Pradhan C Ziaee H Moss M Freeman J McMinn DJW

We report a retrospective review of the incidence of venous thromboembolism in 463 consecutive patients who underwent primary total hip arthroplasty (487 procedures). Treatment included both total hip replacement and hip resurfacing, and the patients were managed without anticoagulants. The thromboprophylaxis regimen included an antiplatelet agent, generally aspirin, hypotensive epidural anaesthesia, elastic compression stockings and early mobilisation. In 258 of these procedures (244 patients) performed in 2005 (cohort A) mechanical compression devices were not used, whereas in 229 (219 patients) performed during 2006 (cohort B) bilateral intermittent pneumatic calf compression was used.

All operations were performed through a posterior mini-incision approach. Patients who required anticoagulation for pre-existing medical problems and those undergoing revision arthroplasty were excluded. Doppler ultrasonographic screening for deep-vein thrombosis was performed in all patients between the fourth and sixth post-operative days. All patients were reviewed at a follow-up clinic six to ten weeks after the operation. In addition, reponse to a questionnaire was obtained at the end of 12 weeks post-operatively.

No symptomatic calf or above-knee deep-vein thrombosis or pulmonary embolism occurred. In 25 patients in cohort A (10.2%) and in ten patients in cohort B (4.6%) asymptomatic calf deep-vein thromboses were detected ultrasonographically. This difference was statistically significant (p = 0.03). The regimen followed by cohort B offers the prospect of a low incidence of venous thromboembolism without subjecting patients to the higher risk of bleeding associated with anticoagulant use.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 42 - 45
1 Jan 1999
Robinson AHN Palmer CR Villar RN

Primary total hip arthroplasty (THA) is one of the most effective ways of improving quality of life (QoL). We have compared the improvement in QoL in 62 patients who had a cemented revision of a THA with that of 62 primary replacements.

One year after operation the median QoL score had been significantly improved in both groups; from 0.870 to 0.990 in the primary group (p < 0.0001) and from 0.870 to 0.980 in the revised group (p < 0.0001). There was no significant difference in the improvement in scores between the groups (p = 0.29).

When reviewed after four years there was no difference in the pain score for either group (p = 0.89), but that for function had deteriorated significantly. This was associated with revision surgery (p = 0.018) and a low preoperative QoL score (p = 0.004).

We conclude that both primary and revision operations give a significant improvement in the QoL but function after revision may be less durable than after a primary arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 855 - 855
1 Sep 1996
NOLAN PC


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 78 - 81
1 Jan 1996
Chan CLH Villar RN

In a prospective trial we studied 176 consecutive patients having a primary total hip arthroplasty to compare the quality of life before and after operation in non-obese and obese groups. We used a modified Harris hip score and the Rosser Index Matrix to generate these scores, and found that the median preoperative quality of life score for both groups was similar.

During review, both groups showed a corresponding marked improvement in quality of life scores at one and three years. There was no statistically significant difference in the improvement in scores between the non-obese and obese groups. It appears that relative body-weight on its own does not influence the benefit derived from primary total hip arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 178 - 183
1 Feb 2011
Streit MR Merle C Clarius M Aldinger PR

Peri-prosthetic femoral fracture after total hip replacement (THR) is associated with a poor outcome and high mortality. However, little is known about its long-term incidence after uncemented THR.

We retrospectively reviewed a consecutive series of 326 patients (354 hips) who had received a CLS Spotorno replacement with an uncemented, straight, collarless tapered titanium stem between January 1985 and December 1989. The mean follow-up was 17 years (15 to 20). The occurrence of peri-prosthetic femoral fracture during follow-up was noted. Kaplan-Meier survival analysis was used to estimate the cumulative incidence of fracture.

At the last follow-up, 86 patients (89 hips) had died and eight patients (eight hips) had been lost to follow-up. A total of 14 fractures in 14 patients had occurred. In ten hips, the femoral component had to be revised and in four the fracture was treated by open reduction and internal fixation. The cumulative incidence of peri-prosthetic femoral fracture was 1.6% (95% confidence interval 0.7 to 3.8) at ten years and 4.5% (95% confidence interval 2.6 to 8.0) at 17 years after the primary THR. There was no association between the occurrence of fracture and gender or age at the time of the primary replacement.

Our findings indicate that peri-prosthetic femoral fracture is a significant mode of failure in the long term after the insertion of an uncemented CLS Spotorno stem. Revision rates for this fracture rise in the second decade. Further research is required to investigate the risk factors involved in the occurrence of late peri-prosthetic femoral fracture after the implantation of any uncemented stem, and to assess possible methods of prevention.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 650 - 658
1 Apr 2021
Konow T Baetz J Melsheimer O Grimberg A Morlock M

Aims. Periprosthetic femoral fractures (PPF) are a serious complication of total hip arthroplasty (THA) and are becoming an increasingly common indication for revision arthroplasty with the ageing population. This study aimed to identify potential risk factors for PPF based on an analysis of registry data. Methods. Cases recorded with PPF as the primary indication for revision arthroplasty in the German Arthroplasty Registry (Endoprothesenregister Deutschland (EPRD)), as well as those classified as having a PPF according to the International Classification of Diseases (ICD) codes in patients’ insurance records were identified from the complete datasets of 249,639 registered primary hip arthroplasties in the EPRD and included in the analysis. Results. The incidence of PPFs was higher (24.6%; 1,483) than reported in EPRD annual reports listing PPF as the main reason for revision (10.9%; 654). The majority of fractures occurred intraoperatively and were directly related to the implantation process. Patients who were elderly, female, or had comorbidities were at higher risk of PPFs (p < 0.001). German hospitals with a surgical volume of < 300 primary procedures per year had a higher rate of PPFs (p < 0.001). The use of cemented and collared prostheses had a lower fracture risk PPF compared to uncemented and collarless components, respectively (both p < 0.001). Collared prostheses reduced the risk of PPF irrespective of the fixation method and hospital’s surgical volume. Conclusion. The high proportion of intraoperative fractures emphasises the need to improve surgeon training and surgical technique. Registry data should be interpreted with caution because of potential differences in coding standards between institutions. Cite this article: Bone Joint J 2021;103-B(4):650–658


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1209 - 1217
1 Oct 2019
Zeng C Lane NE Englund M Xie D Chen H Zhang Y Wang H Lei G

Aims. There is an increasing demand for hip arthroplasty in China. We aimed to describe trends in in-hospital mortality after this procedure in China and to examine the potential risk factors. Patients and Methods. We included 210 450 patients undergoing primary hip arthroplasty registered in the Hospital Quality Monitoring System in China between 2013 and 2016. In-hospital mortality after hip arthroplasty and its relation to potential risk factors were assessed using multivariable Poisson regression. Results. During the study period, 626 inpatient deaths occurred within 30 days after hip arthroplasty. Mortality decreased from 2.9% in 2013 to 2.6% in 2016 (p for trend = 0.02). Compared with their counterparts, old age, male sex, and divorced or widowed patients had a higher rate of mortality (all p < 0.05). Risk ratio (RR) for mortality after arthroplasty for fracture was two-fold higher (RR 2.0, 95% confidence interval (CI) 1.5 to 2.6) than that for chronic disease. RRs for mortality were 3.3 (95% CI 2.7 to 3.9) and 8.2 (95% CI 6.5 to 10.4) for patients with Charlson Comorbidity Index (CCI) of 1 to 2 and CCI ≥ 3, respectively, compared with patients with CCI of 0. The rate of mortality varied according to geographical region, the lowest being in the East region (1.8%), followed by Beijing (2.1%), the North (2.9%), South-West (3.6%), South-Central (3.8%), North-East (4.1%), and North-West (5.2%) regions. Conclusion. While in-hospital mortality after hip arthroplasty in China appears low and declined during the study period, discrepancies in mortality after this procedure exist according to sociodemographic factors. Healthcare resources should be allocated more to underdeveloped regions to further reduce mortality. Cite this article: Bone Joint J 2019;101-B:1209–1217


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 81 - 88
1 Mar 2024
Lustig S Cotte M Foissey C Asirvatham RD Servien E Batailler C

Aims

The benefit of a dual-mobility acetabular component (DMC) for primary total hip arthroplasties (THAs) is controversial. This study aimed to compare the dislocation and complication rates when using a DMC compared to single-mobility (SM) acetabular component in primary elective THA using data collected at a single centre, and compare the revision rates and survival outcomes in these two groups.

Methods

Between 2010 and 2019, 2,075 primary THAs using either a cementless DM or SM acetabular component were included. Indications for DMC were patients aged older than 70 years or with high risk of dislocation. All other patients received a SM acetabular component. Exclusion criteria were cemented implants, patients treated for femoral neck fracture, and follow-up of less than one year. In total, 1,940 THAs were analyzed: 1,149 DMC (59.2%) and 791 SM (40.8%). The mean age was 73 years (SD 9.2) in the DMC group and 57 years (SD 12) in the SM group. Complications and revisions have been analyzed retrospectively.


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 687 - 695
1 Jun 2022
Sabah SA Knight R Alvand A Beard DJ Price AJ

Aims

Routinely collected patient-reported outcome measures (PROMs) have been useful to quantify and quality-assess provision of total hip arthroplasty (THA) and total knee arthroplasty (TKA) in the UK for the past decade. This study aimed to explore whether the outcome following primary THA and TKA had improved over the past seven years.

Methods

Secondary data analysis of 277,430 primary THAs and 308,007 primary TKAs from the NHS PROMs programme was undertaken. Outcome measures were: postoperative Oxford Hip/Knee Score (OHS/OKS); proportion of patients achieving a clinically important improvement in joint function (responders); quality of life; patient satisfaction; perceived success; and complication rates. Outcome measures were compared based on year of surgery using multiple linear and logistic regression models.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1522 - 1526
1 Nov 2010
McGrory BJ McGrory CP Barbour L Barbour B

Dislocation is a common and well-studied complication after total hip replacement. However, subluxation, which we define as a clinically recognised episode of incomplete movement of the femoral head outside the acetabulum with spontaneous reduction, has not been studied previously. Out of a total of 2521 hip replacements performed over 12 years by one surgeon, 30 patients experienced subluxations which occurred in 31 arthroplasties. Data were collected prospectively with a minimum follow-up of two years. Subluxation occurred significantly more frequently after revision than after primary hip replacement, and resolved in 19 of 31 cases (61.3%). In six of the 31 hips (19.4%) the patient subsequently dislocated the affected hip, and in six hips (19.4%) intermittent subluxation continued. Four patients had a revision operation for instability, three for recurrent dislocation and one for recurrent subluxation. Clinical and radiological comparisons with a matched group of stable total hips showed no correlation with demographic or radiological parameters. Patients with subluxing hips reported significantly more concern that their hip would dislocate, more often changed their behaviour to prevent instability and had lower postoperative Harris hip scores than patients with stable replacements


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 467 - 470
1 May 2023
McBryde CW Prakash R Haddad FS


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1321 - 1326
1 Dec 2023
Schlenzka T Serlo J Viljakka T Tallroth K Helenius I

Aims

We aimed to assess the cumulative risk of total hip arthroplasty (THA) from in situ fixation for slipped capital femoral epiphysis (SCFE) after a follow-up of almost 50 years.

Methods

In this study, 138 patients with 172 affected hips treated with in situ fixation were evaluated retrospectively. A total of 97 patients (70%) were male and the mean age was 13.6 years (SD 2.1); 35 patients (25%) had a bilateral disease. The median follow-up time was 49 years (interquartile range 43 to 55). Basic demographic, stability, and surgical details were obtained from patient records. Preoperative radiographs (slip angle; SA) were measured, and data on THA was gathered from the Finnish National Arthroplasty Register.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 67 - 73
1 Mar 2024
Laboudie P Hallé A Anract P Hamadouche M

Aims

The aim of this retrospective study was to assess the incidence of early periprosthetic femoral fracture (PFF) associated with Charnley-Kerboull (CK) femoral components cemented according to the ‘French paradox’ principles through the Hueter anterior approach (HAA) in patients older than 70 years.

Methods

From a prospectively collected database, all short CK femoral components implanted consecutively from January 2018 to May 2022 through the HAA in patients older than 70 years were included. Exclusion criteria were age below 70 years, use of cementless femoral component, and approaches other than the HAA. A total of 416 short CK prostheses used by 25 surgeons with various levels of experience were included. All patients had a minimum of one-year follow-up, with a mean of 2.6 years (SD 1.1). The mean age was 77.4 years (70 to 95) and the mean BMI was 25.3 kg/m2 (18.4 to 43). Femoral anatomy was classified according to Dorr. The measured parameters included canal flare index, morphological cortical index, canal-calcar ratio, ilium-ischial ratio, and anterior superior iliac spine to greater trochanter (GT) distance.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 59 - 65
1 May 2024
Liu WKT Cheung A Fu H Chan PK Chiu KY

Aims

Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following total hip arthroplasty (THA) in the presence of a well-fixed acetabular shell. The liner can be fixed either with the original locking mechanism or by being cemented within the acetabular component. Whether the method used for fixation of the HXLPE liner has any bearing on the long-term outcomes is still unclear.

Methods

Data were retrieved for all patients who underwent isolated acetabular component liner exchange surgery with a HXLPE component in our institute between August 2000 and January 2015. Patients were classified according to the fixation method used (original locking mechanism (n = 36) or cemented (n = 50)). Survival and revision rates were compared. A total of 86 revisions were performed and the mean duration of follow-up was 13 years.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 504 - 510
1 May 2023
Evans JT Salar O Whitehouse SL Sayers A Whitehouse MR Wilton T Hubble MJW

Aims

The Exeter V40 femoral stem is the most implanted stem in the National Joint Registry (NJR) for primary total hip arthroplasty (THA). In 2004, the 44/00/125 stem was released for use in ‘cement-in-cement’ revision cases. It has, however, been used ‘off-label’ as a primary stem when patient anatomy requires a smaller stem with a 44 mm offset. We aimed to investigate survival of this implant in comparison to others in the range when used in primary THAs recorded in the NJR.

Methods

We analyzed 328,737 primary THAs using the Exeter V40 stem, comprising 34.3% of the 958,869 from the start of the NJR to December 2018. Our exposure was the stem, and the outcome was all-cause construct revision. We stratified analyses into four groups: constructs using the 44/00/125 stem, those using the 44/0/150 stem, those including a 35.5/125 stem, and constructs using any other Exeter V40 stem.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 864 - 867
1 Jul 2007
Roberts VI Esler CN Harper WM

The National Institute for Clinical Excellence (NICE) published the guidelines on the selection of prostheses for primary hip replacement in 2000. They supported the use of cemented hip prostheses to the exclusion of uncemented and hybrid implants. The information from the Trent (and Wales) Regional Arthroplasty Study has been examined to identify retrospectively the types of hip prostheses used between 1990 and 2005, and to assess the impact that the guidelines have had on orthopaedic practice. The results show that the publication of the NICE guidelines has had little impact on clinical practice, with the use of uncemented prostheses increasing from 6.7% (137) in 2001 to 19.2% (632) in 2005. The use of hybrid prostheses has more than doubled from 8.8% (181) to 22% (722) of all hips implanted in the same period. The recommendations made by NICE are not being followed, which calls into question their value


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 84 - 87
1 Jan 2008
Tillman RM Myers GJC Abudu AT Carter SR Grimer RJ

Pathological fractures due to metastasis with destruction of the acetabulum and central dislocation of the hip present a difficult surgical challenge. We describe a series using a single technique in which a stable and long-lasting reconstruction was obtained using standard primary hip replacement implants augmented by strong, fully-threaded steel rods with cement and steel mesh, where required. Between 1997 and 2006, 19 patients with a mean age of 66 years (48 to 83) were treated using a modified Harrington technique. Acetabular destruction was graded as Harrington class II in six cases and class III in 13. Reconstruction was achieved using three 6.5 mm rods inserted through a separate incision in the iliac crest followed by augmentation with cement and a conventional cemented Charnley or Exeter primary hip replacement. There were no peri-operative deaths. At the final follow-up (mean 25 months (5 to 110)) one rod had fractured and one construct required revision. Of the 18 patients who did not require revision, 13 had died. The mean time to death was 16 months (5 to 55). The mean follow-up of the five survivors was 31 months (18 to 47). There were no cases of dislocation, deep infection or injury to a nerve, the blood vessels or the bladder


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1110 - 1117
12 Oct 2022
Wessling M Gebert C Hakenes T Dudda M Hardes J Frieler S Jeys LM Hanusrichter Y

Aims

The aim of this study was to examine the implant accuracy of custom-made partial pelvis replacements (PPRs) in revision total hip arthroplasty (rTHA). Custom-made implants offer an option to achieve a reconstruction in cases with severe acetabular bone loss. By analyzing implant deviation in CT and radiograph imaging and correlating early clinical complications, we aimed to optimize the usage of custom-made implants.

Methods

A consecutive series of 45 (2014 to 2019) PPRs for Paprosky III defects at rTHA were analyzed comparing the preoperative planning CT scans used to manufacture the implants with postoperative CT scans and radiographs. The anteversion (AV), inclination (IC), deviation from the preoperatively planned implant position, and deviation of the centre of rotation (COR) were explored. Early postoperative complications were recorded, and factors for malpositioning were sought. The mean follow-up was 30 months (SD 19; 6 to 74), with four patients lost to follow-up.


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1060 - 1066
1 Sep 2022
Jin X Gallego Luxan B Hanly M Pratt NL Harris I de Steiger R Graves SE Jorm L

Aims

The aim of this study was to estimate the 90-day periprosthetic joint infection (PJI) rates following total knee arthroplasty (TKA) and total hip arthroplasty (THA) for osteoarthritis (OA).

Methods

This was a data linkage study using the New South Wales (NSW) Admitted Patient Data Collection (APDC) and the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), which collect data from all public and private hospitals in NSW, Australia. Patients who underwent a TKA or THA for OA between 1 January 2002 and 31 December 2017 were included. The main outcome measures were 90-day incidence rates of hospital readmission for: revision arthroplasty for PJI as recorded in the AOANJRR; conservative definition of PJI, defined by T84.5, the PJI diagnosis code in the APDC; and extended definition of PJI, defined by the presence of either T84.5, or combinations of diagnosis and procedure code groups derived from recursive binary partitioning in the APDC.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 412 - 418
1 Mar 2012
Judge A Arden NK Kiran A Price A Javaid MK Beard D Murray D Field RE

We obtained information from the Elective Orthopaedic Centre on 1523 patients with baseline and six-month Oxford hip scores (OHS) after undergoing primary hip replacement (THR) and 1784 patients with Oxford knee scores (OKS) for primary knee replacement (TKR) who completed a six-month satisfaction questionnaire. Receiver operating characteristic curves identified an absolute change in OHS of 14 points or more as the point that discriminates best between patients’ satisfaction levels and an 11-point change for the OKS. Satisfaction is highest (97.6%) in patients with an absolute change in OHS of 14 points or more, compared with lower levels of satisfaction (81.8%) below this threshold. Similarly, an 11-point absolute change in OKS was associated with 95.4% satisfaction compared with 76.5% below this threshold. For the six-month OHS a score of 35 points or more distinguished patients with the highest satisfaction level, and for the six-month OKS 30 points or more identified the highest level of satisfaction. The thresholds varied according to patients’ pre-operative score, where those with severe pre-operative pain/function required a lower six-month score to achieve the highest levels of satisfaction. Our data suggest that the choice of a six-month follow-up to assess patient-reported outcomes of THR/TKR is acceptable. The thresholds help to differentiate between patients with different levels of satisfaction, but external validation will be required prior to general implementation in clinical practice


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 987 - 996
1 Aug 2022

Aims

The aim of this study was to describe the demographic details of patients who sustain a femoral periprosthetic fracture (PPF), the epidemiology of PPFs, PPF characteristics, and the predictors of PPF types in the UK population.

Methods

This is a multicentre retrospective cohort study including adult patients presenting to hospital with a new PPF between 1 January 2018 and 31 December 2018. Data collected included: patient characteristics, comorbidities, anticoagulant use, social circumstances, level of mobility, fracture characteristics, Unified Classification System (UCS) type, and details of the original implant. Descriptive analysis by fracture location was performed, and predictors of PPF type were assessed using mixed-effects logistic regression models.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 801 - 810
1 Jul 2022
Krull P Steinbrück A Grimberg AW Melsheimer O Morlock M Perka C

Aims

Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA).

Methods

We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 206 - 211
1 Feb 2022
Bloch BV White JJE Matar HE Berber R Manktelow ARJ

Aims

Total hip arthroplasty (THA) is a very successful and cost-effective operation, yet debate continues about the optimum fixation philosophy in different age groups. The concept of the 'cementless paradox' and the UK 'Getting it Right First Time' initiative encourage increased use of cemented fixation due to purported lower revision rates, especially in elderly patients, and decreased cost.

Methods

In a high-volume, tertiary referral centre, we identified 10,112 THAs from a prospectively collected database, including 1,699 cemented THAs, 5,782 hybrid THAs, and 2,631 cementless THAs. The endpoint was revision for any reason. Secondary analysis included examination of implant survivorship in patients aged over 70 years, over 75 years, and over 80 years at primary THA.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 212 - 220
1 Feb 2022
Fishley WG Selvaratnam V Whitehouse SL Kassam AM Petheram TG

Aims

Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of hip arthroplasty necessitate removal of all bone cement from the femur. In our two centres, we have been using a cement-in-cement technique, leaving the distal femoral bone cement in selected patients for septic hip revision surgery, both for single and the first of two-stage revision procedures. A prerequisite for adoption of this technique is that the surgeon considers the cement mantle to be intimately fixed to bone without an intervening membrane between cement and host bone. We aim to report our experience for this technique.

Methods

We have analyzed patients undergoing this cement-in-cement technique for femoral revision in infection, and present a consecutive series of 89 patients. Follow-up was undertaken at a mean of 56.5 months (24.0 to 134.7) for the surviving cases.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 66 - 69
1 Nov 2014
Lombardi Jr AV Berend KR Adams JB

The common recommended treatment for infected total hip replacement is two-staged exchange including removal of all components. However, removal of well-fixed femoral stems can result in structural bone damage. We recently reported on an alternative treatment of partial two-stage exchange used in selected cases, in which a well-fixed femoral stem was left and only the acetabular component removed, the joint space was debrided thoroughly, an antibiotic-laden polymethylmethacrylate spacer was moulded using a bulb-type syringe and placed in the acetabulum, intravenous antibiotics were administered during the interval, and delayed re-implantation was performed. In 19 patients treated with this technique from January 2000 to January 2011, 89% were free of infection at a mean follow-up of four years (2 to 11). Since then, disposable silicone moulds have become available to fabricate spacers in separate femoral and head units. The head spacer mould, which incorporates various neck taper adapter options, greatly facilitates the technique of partial two-stage exchange. We report our early experience using disposable silicone head spacer moulds for partial two-stage exchange in seven patients with infected primary hip replacements. Cite this article: Bone Joint J 2014;96-B(11 Suppl A):66–9


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 59 - 67
1 Jan 2022
Kingsbury SR Smith LK Shuweihdi F West R Czoski Murray C Conaghan PG Stone MH

Aims

The aim of this study was to conduct a cross-sectional, observational cohort study of patients presenting for revision of a total hip, or total or unicompartmental knee arthroplasty, to understand current routes to revision surgery and explore differences in symptoms, healthcare use, reason for revision, and the revision surgery (surgical time, components, length of stay) between patients having regular follow-up and those without.

Methods

Data were collected from participants and medical records for the 12 months prior to revision. Patients with previous revision, metal-on-metal articulations, or hip hemiarthroplasty were excluded. Participants were retrospectively classified as ‘Planned’ or ‘Unplanned’ revision. Multilevel regression and propensity score matching were used to compare the two groups.


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1479 - 1487
1 Sep 2021
Davis ET Pagkalos J Kopjar B

Aims

The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs).

Methods

We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 293 - 297
1 Mar 2011
Labek G Thaler M Janda W Agreiter M Stöckl B

In a systematic review, reports from national registers and clinical studies were identified and analysed with respect to revision rates after joint replacement, which were calculated as revisions per 100 observed component years. After primary hip replacement, a mean of 1.29 revisions per 100 observed component years was seen. The results after primary total knee replacement are 1.26 revisions per 100 observed component years, and 1.53 after medial unicompartmental replacement. After total ankle replacement a mean of 3.29 revisions per 100 observed component years was seen. The outcomes of total hip and knee replacement are almost identical. Revision rates of about 6% after five years and 12% after ten years are to be expected


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 479 - 485
1 Mar 2021
Nugent M Young SW Frampton CM Hooper GJ

Aims

Joint registries typically use revision of an implant as an endpoint and report survival rates after a defined number of years. However, reporting lifetime risk of revision may be more meaningful, especially in younger patients. We aimed to assess lifetime risk of revision for patients in defined age groups at the time of primary surgery.

Methods

The New Zealand Joint Registry (NZJR) was used to obtain rates and causes of revision for all primary total hip arthroplasties (THAs) performed between January 1999 and December 2016. The NZJR is linked to the New Zealand Registry of Births, Deaths and Marriages to obtain complete and accurate data. Patients were stratified by age at primary surgery, and lifetime risk of revision calculated according to age, sex, and American Society of Anesthesiologists (ASA) classification. The most common causes for revision were also analyzed for each age group.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 409 - 413
1 Mar 2011
McCalden RW Charron KD Davidson RD Teeter MG Holdsworth DW

We present a case of early retrieval of an Oxinium femoral head and corresponding polyethylene liner where there was significant surface damage to the head and polyethylene. The implants were retrieved at the time of revision surgery to correct leg-length discrepancy just 48 hours after the primary hip replacement. Appropriate analysis of the retrieved femoral head demonstrated loss of the Oxinium layer with exposure of the underlying substrate and transfer of titanium from the acetabular shell at the time of a reduction of the index total hip replacement. In addition, the level of damage to the polyethylene was extensive despite only 48 hours in situ. The purpose of this report is to highlight the care that is required at the time of reduction, especially with these hard femoral counter-faces such as Oxinium. To our knowledge, the damage occurring at the time of reduction has not been previously reported following the retrieval of an otherwise well-functioning hip replacement


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 573 - 579
1 May 2020
Krueger DR Guenther K Deml MC Perka C

Aims

We evaluated a large database with mechanical failure of a single uncemented modular femoral component, used in revision hip arthroplasty, as the end point and compared them to a control group treated with the same implant. Patient- and implant-specific risk factors for implant failure were analyzed.

Methods

All cases of a fractured uncemented modular revision femoral component from one manufacturer until April 2017 were identified and the total number of implants sold until April 2017 was used to calculate the fracture rate. The manufacturer provided data on patient demographics, time to failure, and implant details for all notified fractured devices. Patient- and implant-specific risk factors were evaluated using a logistic regression model with multiple imputations and compared to data from a previously published reference group, where no fractures had been observed. The results of a retrieval analysis of the fractured implants, performed by the manufacturer, were available for evaluation.


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 129 - 134
1 Jul 2021
Ayekoloye CI Abu Qa'oud M Radi M Leon SA Kuzyk P Safir O Gross AE

Aims

Improvements in functional results and long-term survival are variable following conversion of hip fusion to total hip arthroplasty (THA) and complications are high. The aim of the study was to analyze the clinical and functional results in patients who underwent conversion of hip fusion to THA using a consistent technique and uncemented implants.

Methods

A total of 39 hip fusion conversions to THA were undertaken in 38 patients by a single surgeon employing a consistent surgical technique and uncemented implants. Parameters assessed included Harris Hip Score (HHS) for function, range of motion (ROM), leg length discrepancy (LLD), satisfaction, and use of walking aid. Radiographs were reviewed for loosening, subsidence, and heterotopic ossification (HO). Postoperative complications and implant survival were assessed.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1454 - 1458
1 Nov 2009
Eswaramoorthy VK Biant LC Field RE

We report the outcome of total hip replacement in 29 failed metal-on-metal resurfacing hip replacements in which the primary surgery was performed between August 1995 and February 2005. The mean length of follow-up was five years (1.7 to 11.7). Of the 29 hip resurfacings, 19 acetabular components and all the femoral components were revised (28 uncemented stems and one cemented stem). There were no deaths and none of the patients was lost to follow-up. None of the hips underwent any further revision. The results of the revision resurfacing group were compared with those of a control group of age-matched patients. In the latter group there were 236 primary total hip replacements and 523 resurfacings performed during the same period by the same surgeons. The outcome of the revision resurfacing group was comparable with that of the stemmed primary hip replacement group but was less good than that of the primary hip resurfacing group. Long-term follow-up is advocated to monitor the outcome of these cases


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 188 - 191
1 Mar 2000
Journeaux SF Morgan DAF Donnelly WJ

We have reviewed 202 consecutive primary hip replacements using a Freeman cemented femoral component after a mean period of follow-up of 64 months (23 to 113). There was only one revision for aseptic loosening. Retention of the femoral neck may act to reduce the torsional and shear forces at the implant-cement interface and may provide a seal against the migration of polyethylene-laden joint fluid in the potential joint space. The cemented Freeman femoral component with retention of the femoral neck was successful for up to nine years


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 103 - 110
1 Jul 2021
Chalmers BP Lebowitz JS Chiu Y Joseph AD Padgett DE Bostrom MPG Gonzalez Della Valle A

Aims

Due to the opioid epidemic in the USA, our service progressively decreased the number of opioid tablets prescribed at discharge after primary hip (THA) and knee (TKA) arthroplasty. The goal of this study was to analyze the effect on total morphine milligram equivalents (MMEs) prescribed and post-discharge opioid repeat prescriptions.

Methods

We retrospectively reviewed 19,428 patients undergoing a primary THA or TKA between 1 February 2016 and 31 December 2019. Two reductions in the number of opioid tablets prescribed at discharge were implemented over this time; as such, we analyzed three periods (P1, P2, and P3) with different routine discharge MME (750, 520, and 320 MMEs, respectively). We investigated 90-day refill rates, refill MMEs, and whether discharge MMEs were associated with represcribing in a multivariate model.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 797 - 800
1 Aug 2004
James LA Ibrahim T Esler CN

We determined the rate of contamination of donated femoral heads at primary hip arthroplasty within a single region between July 1992 and July 2001. We established the null hypothesis that culture results played no role in predicting early failure of the joint because of infection. The rate of contamination was 9%. A positive culture, at the time of retrieval, was found in 367 of 4045 femoral heads. Coagulase-negative staphylococcus was isolated in 77% of the positive cases. At a minimum follow-up of one year, there was no statistically significant difference in the rate of complications or of revision of age-matched patients whose femoral heads had a positive culture compared with those whose femoral heads were sterile. Our findings confirm that culture of the femoral head plays no part in determining future failure of joint replacement in the donor


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1210 - 1215
1 Sep 2005
Pospischill M Knahr K

We carried out a clinical and radiological review of 103 cementless primary hip arthroplasties with a tapered rectangular grit-blasted titanium press-fit femoral component and a threaded conical titanium acetabular component at a mean follow-up of 14.4 years (10.2 to 17.1). The mean Harris hip score at the last follow-up was 89.2 (32 to 100). No early loosening and no fracture of the implant were found. One patient needed revision surgery because of a late deep infection. In 11 hips (10.7%), the reason for revision was progressive wear of the polyethylene liner. Exchange of the acetabular component because of aseptic loosening without detectable liner wear was carried out in three hips (2.9%). After 15 years the survivorship with aseptic loosening as the definition for failure was 95.6% for the acetabular component and 100% for the femoral component


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 608 - 615
1 Jul 1993
Schmalzried T Harris W

We have reviewed 97 consecutive primary hip replacements with a cemented femoral component and a porous-ingrowth acetabular component at a minimum five-year follow-up (average 6.5 years). The average Harris hip score was 93, and 85 hips had no pain or only slight pain. There had been no deterioration in the results since the two-year follow-up. The hybrid hip is successful for up to eight years and appears to be suitable for many patients. Long-term femoral fixation has been shown to improve with second-generation cementing techniques and in this series was excellent with third-generation techniques, in that only one stem was revised for loosening. No cementless acetabular component was revised for loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1675 - 1680
1 Dec 2005
Howie C Hughes H Watts AC

This population-based study investigated the incidence and trends in venous thromboembolic disease after total hip and knee arthroplasty over a ten-year period. Death or readmission for venous thromboembolic disease up to two years after surgery for all patients in Scotland was the primary outcome. The incidence of venous thromboembolic disease, including fatal pulmonary embolism, three months after surgery was 2.27% for primary hip arthroplasty and 1.79% for total knee arthroplasty. The incidence of fatal pulmonary embolism within three months was 0.22% for total hip arthroplasty and 0.15% for total knee arthroplasty. The majority of events occurred after hospital discharge, with no apparent trend over the period. The data support current advice that prophylaxis should be continued for at least six weeks following surgery. Despite the increased use of policies for prophylaxis and earlier mobilisation, there has been no change in the incidence of venous thromboembolic disease


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 674 - 676
1 May 2008
May O Girard J Hurtevent JF Migaud H

Delayed sciatic nerve palsy is uncommon after primary hip replacement. Two kinds of sciatic palsy have been reported with regard to the time of onset: early palsy related to wound haematoma or lumbosacral nerve elongation which occurs between surgery and 18 days, is more frequent than delayed palsy, occurring between 10 and 32 months, which is usually caused by cement extrusion or heat produced by cement polymerisation. We present two cases of delayed, transient sciatic nerve palsy arising at three weeks and four months after primary cementless arthroplasty, respectively, without haematoma and with a normal lumbar spine. These palsies were possibly caused by excessive tension from minor limb lengthening of 2 cm to 4 cm required to achieve leg-length equality. As the initial symptoms were limited to calf pain and mild numbness in the foot, surgeons should be aware of this mode of onset, particularly when it is delayed after hip replacement. Both patients recovered fully by 12 months after surgery so we did not undertake surgical exploration of the nerve in either patient


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 240 - 244
1 Mar 1994
Alsema R Deutman R Mulder T

In 1988 we reported a ten-year review of 83 surviving patients from a group of 135 (146 prostheses) who had undergone primary hip replacement using the Stanmore prosthesis. We have now reviewed 44 of these patients at 15 to 16 years. Four patients had undergone revision, but the other 40 were all satisfied with the result of their hip replacement, 36 having little or no pain. Functional activities had decreased, but were still adequate for their average age of 81 years. There had been definite migration of the cup and/or femoral component in three hips, wear of the cup in ten and resorption of the calcar in six. Of the 24 hips inserted with radiopaque cement, eight showed an increase in radiolucent lines at the acetabular interface. The cumulative survival rate of the prosthesis was 91% at 15 to 16 years


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 97 - 102
1 Jan 2000
Gerritsma-Bleeker CLE Deutman R Mulder TJ Steinberg JDJ

From a series of 135 patients (146 prostheses) who had had primary hip replacement in 1975 and 1976 we reported the outcome at ten years in 83 surviving patients in 1988 and that at 15 years in 44 surviving patients in 1994. Now, 22 years after the operation, we have reviewed the 21 patients who are still alive. Nineteen (20 hips) of these 21 patients (22 hips) with a mean age of 85.7 years still had their original prosthesis. Most patients were satisfied with the result, although the level of activity in many was reduced because of increasing age and other medical problems. The stem was stable in all 20 hips. Only one cup was definitely loose. Wear was observed in 40% of the cups but this was not a clinical problem. At the 22-year follow-up the cumulative survival rate of the prosthesis was 85%, of the stem 91% and of the cup 88%. Since 1975, 11 (7.5%) of the original 146 prostheses have been revised


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1256 - 1258
1 Sep 2005
Al-Maiyah M Hill D Bajwa A Slater S Patil P Port A Gregg PJ

We have investigated the contaminating bacteria in primary hip arthroplasty and their sensitivity to the prophylactic antibiotics currently in use. Impressions (627) of the gloved hands of the surgical team in 50 total hip arthroplasties were obtained on blood agar. The gloves were changed after draping, at intervals of 20 minutes thereafter, and before using cement. Changes were also undertaken whenever a visible puncture was detected. The culture plates were incubated at 37°C for 48 hours. Isolates were identified and tested for sensitivity to flucloxacillin, which is a recognised indicator of sensitivity to cefuroxime. They were also tested against other agents depending upon their appearance on Gram staining. We found contamination in 57 (9%) impressions and 106 bacterial isolates. Coagulase-negative staphylococci were seen most frequently (68.9%), but we also isolated Micrococcus (12.3%), diphtheroids (9.4%), Staphylococcus aureus (6.6%) and Escherichia coli (0.9%). Of the coagulase-negative staphylococci, only 52.1% were sensitive to flucloxacillin and therefore to cefuroxime. We believe that it is now appropriate to review the relevance of prophylaxis with cefuroxime and to consider the use of other agents


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 319 - 323
1 Mar 2008
Moonot P Singh PJ Cronin MD Kalairajah YE Kavanagh TG Field RE

Hip resurfacing is a bone-conserving procedure with respect to proximal femoral resection, but there is debate in the literature as to whether the same holds true for the acetabulum. We have investigated whether the Birmingham hip resurfacing conserves acetabular bone. Between 1998 and 2005, 500 Birmingham hip resurfacings were performed by two surgeons. Between 1996 and 2005 they undertook 700 primary hip replacements, with an uncemented acetabular component. These patients formed the clinical material to compare acetabular component sizing. The Birmingham hip resurfacing group comprised 350 hips in men and 150 hips in women. The uncemented total hip replacement group comprised 236 hips in men and 464 hips in women. Age- and gender-matched analysis of a cohort of patients for the sizes of the acetabular components required for the two types of replacement was also undertaken. Additionally, an analysis of the sizes of the components used by each surgeon was performed. For age-matched women, the mean outside diameter of the Birmingham hip resurfacing acetabular components was 2.03 mm less than that of the acetabular components in the uncemented total hip replacements (p < 0.0001). In similarly matched men there was no significant difference (p = 0.77). A significant difference was also found between the size of acetabular components used by the two surgeons for Birmingham hip resurfacing for both men (p = 0.0015) and women (p = 0.001). In contrast, no significant difference was found between the size of acetabular components used by the two surgeons for uncemented total hip replacement in either men or women (p = 0.06 and p = 0.14, respectively). This suggests that variations in acetabular preparation also influence acetabular component size in hip resurfacing


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 721 - 726
1 Jun 2006
Girard J Lavigne M Vendittoli P Roy AG

We have compared the biomechanical nature of the reconstruction of the hip in conventional total hip arthroplasty (THA) and surface replacement arthroplasty (SRA) in a randomised study involving 120 patients undergoing unilateral primary hip replacement. The contralateral hip was used as a control. Post-operatively, the femoral offset was significantly increased with THA (mean 5.1 mm; −2.8 to 11.6) and decreased with SRA (mean −3.3 mm; −8.9 to 8.2). Femoral offset was restored within . sd. 4 mm in 14 (25%) of those with THA and in 28 (57%) of the patients receiving SRA (p < 0.001). In the THA group, the leg was lengthened by a mean of 2.6 mm (−6.04 to +12.9), whereas it was shortened by a mean of 1.9 mm (−7.1 to +2.05) in the SRA group, compared with the contralateral side. Leg-length inequality was restored within . sd. 4 mm in 42 (86%) of the SRA and 33 (60%) of the THA patients. The radiological parameters of acetabular reconstruction were similar in both groups. Restoration of the normal proximal femoral anatomy was more precise with SRA. The enhanced stability afforded by the use of a large-diameter femoral head avoided over-lengthening of the limb or increased offset to improve soft-tissue tension as occurs sometimes in THA. In a subgroup of patients with significant pre-operative deformity, restoration of the normal hip anatomy with lower pre-operative femoral offset or significant shortening of the leg was still possible with SRA


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 413 - 418
1 May 1994
Niinimaki T Puranen J Jalovaara P

From 1983 to 1985 we performed 114 primary hip replacements in 108 consecutive osteoarthritic patients using a non-cemented RM isoelastic femoral stem. After a mean follow-up of 8.2 years, ten patients had died, 11 hips had been revised, six patients had been lost to follow-up and two had been excluded due to severe general illnesses. Of 85 arthroplasties (in 79 patients) 14 could not be assessed because of other illness or disability. The 71 remaining were reviewed by questionnaire and radiography; an excellent or good overall functional result was found in 31, 16 were fair and 24 were poor. Radiographically, 21 of 71 stems were judged to be loose and ten showed osteolytic foci, six of these without obvious loosening. We conclude that the isoelastic RM stem shows a high rate of loosening, but that this is not always associated with a poor subjective result. Regular radiographic review is necessary. The results are worse than those reported for other uncemented stems and for cemented stems