Aims. The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a
Aims. The aim of this study was to examine trends in the management of
Aims. We conducted a study to determine whether radiological parameters
correlate with patient reported functional outcome, health-related
quality of life and physical measures of function in patients with
a
We retrospectively reviewed 183 children with a simple
We performed a prospective, randomised study on 57 patients older than 60 years of age with unstable, extra-articular
This article is a systematic review of the published
literature about the biomechanics, functional outcome and complications
of intramedullary nailing of
The recent development of locking-plate technology has led to a potential revolution in the management of
A randomised, prospective study was carried out on 60 patients with unstable
In a randomised prospective study, 20 patients with intra-articular
We conducted an observational radiographic study
to determine the inter- and intra-observer reliability of the AO classification
of
The conventional treatment of comminuted
A total of 118 consecutive patients with a
We performed a prospective, randomised study on 110 patients more than 50 years old with
Interobserver reliability of the AO system of classification of
In a prospective, randomised controlled trial, 68 children who had a completely displaced metaphyseal
The capacity for physiotherapy to improve the outcome after
The fracture most commonly treated by orthopaedic surgeons is that of the distal radius. However, as yet there is no consensus on what constitutes an ‘acceptable’ radiological position before or after treatment. This should be defined as the position that will predict good function in the majority of cases. In this paper we review the radiological indices that can be measured in
In a prospective study of 132 patients with an average age of 35 years, unstable intra-articular
We treated 31 intra-articular
Torus (buckle)
We describe a new technique for open reduction, bone grafting and fixation with a single Kirschner wire of unstable
The Roger Anderson external fixator was used in the treatment of unstable
Fractures of the distal radius occurring in young adults are treated increasingly by open surgical techniques, partly because of concern that failure to restore the alignment of the fracture accurately may cause symptomatic post-traumatic osteoarthritis in future years. We reviewed 106 adults who had sustained a
A total of 179 adult patients with displaced intra-articular
We performed a prospective, randomised trial to evaluate the outcome after surgery of displaced, unstable
We performed a prospective study on 96 patients with extra-articular or intra-articular
We studied prospectively the regional inflammatory response to a unilateral distal radial fracture in 114 patients at eight to nine weeks after injury and again at one year. Our aim was to identify patients at risk for a delayed recovery and particularly those likely to develop complex regional pain syndrome. In order to quantify clinically the inflammatory response, a regional inflammatory score was developed. In addition, blood samples were collected from the antecubital veins of both arms for comparative biochemical and blood-gas analysis. The severity of the inflammatory response was related to the type of treatment (Kruskal-Wallis test, p = 0.002). A highly significantly-positive correlation was found between the regional inflammatory score and the length of time to full recovery (r2 = 0.92, p = 0.01, linear regession). A regional inflammatory score of 5 points with a sensitivity of 100% but a specificity of only 16% also identified patients at risk of complex regional pain syndrome. None of the biochemical parameters studied correlated with regional inflammatory score or predicted the development of complex regional pain syndrome. Our study suggests that patients with a distal radial fracture and a regional inflammatory score of 5 points or more at eight to nine weeks after injury should be considered for specific anti-inflammatory treatment.
Aims. The aim of this study was to compare the clinical effectiveness of Kirschner wire (K-wire) fixation with locking-plate fixation for patients with a dorsally displaced
We identified 11 women with a mean age of 74 years (65 to 81) who sustained comminuted distal radial and ulnar fractures and were treated by volar plating and slight shortening of the radius combined with a primary Sauvé-Kapandji procedure. At a mean of 46 months (16 to 58), union of distal radial fractures and arthrodesis of the distal radioulnar joint was seen in all patients. The mean shortening of the radius was 12 mm (5 to 18) compared to the contralateral side. Flexion and extension of the wrist was a mean of 54° and 50°, respectively, and the mean pronation and supination of the forearm was 82° and 86°, respectively. The final mean disabilities of the arm, shoulder and hand score was 26 points. According to the Green and O’Brien rating system, eight patients had an excellent, two a good and one a fair result. The good clinical and radiological results, and the minor complications without the need for further operations related to late ulnar-sided wrist pain, justify this procedure in the elderly patient.
Displaced
We sought to quantify agreement by different assessors of the AO classification for distal fractures of the radius. Thirty radiographs of acute distal radial fractures were evaluated by 36 assessors of varying clinical experience. Our findings suggest that AO ‘type’ and the presence or absence of articular displacement are measured with high consistency when classification of distal radial fractures is undertaken by experienced observers. Assessors at all experience levels had difficulty agreeing on AO ‘group’ and especially AO ‘subgroup’. To categorise distal radial fractures according to joint displacement and AO type is simple and reproducible. Our study examined only whether distal radial fractures could be consistently classified according to the AO system. Validation of the classification as a predictor of outcome will require a prospective clinical study.
A retrospective study was performed in 100 children
aged between two and 16 years, with a dorsally angulated stable
fracture of the distal radius or forearm, who were treated with
manipulation in the emergency department (ED) using intranasal diamorphine
and 50% oxygen and nitrous oxide. Pre- and post-manipulation radiographs,
the final radiographs and the clinical notes were reviewed. A successful
reduction was achieved in 90 fractures (90%) and only three children
(3%) required remanipulation and Kirschner wire fixation or internal
fixation. The use of Entonox and intranasal diamorphine is safe and effective
for the closed reduction of a stable paediatric fracture of the
distal radius and forearm in the ED. By facilitating discharge on the same day, there is a substantial
cost benefit to families and the NHS and we recommend this method. Take home message: Simple easily reducible fractures of the distal
radius and forearm in children can be successfully and safely treated
in the ED using this approach, thus avoiding theatre admission and
costly hospital stay. Cite this article:
Aims. The aim of this trial was to assess the cost-effectiveness of a soft bandage and immediate discharge, compared with rigid immobilization, in children aged four to 15 years with a torus
Aims. The degree of displacement of a fracture of the distal radius
is an important factor which can be assessed using simple radiographic
measurements. Our aim was to investigate the reliability and reproducibility
of these measurements and to determine if they should be used clinically. Patients and Methods. A 10% sample was randomly generated from 3670 consecutive adult
patients who had presented to University Hospitals of Leicester
NHS Trust between 2007 and 2010 with a
Aims. The management of completely displaced
Aims. Distal radial fractures are the most common fracture sustained by the adult population. Most can be treated using cast immobilization without the need for surgery. The aim of this study was to assess the feasibility of a definitive trial comparing the commonly used fibreglass cast immobilization with an alternative product called Woodcast. Woodcast is a biodegradable casting material with theoretical benefits in terms of patient comfort as well as benefits to the environment. Methods. This was a multicentre, two-arm, open-label, parallel-group randomized controlled feasibility trial. Patients with a
We tested the hypothesis that children who sustain a supracondylar fracture have a greater range of elbow hyperextension than those with a
The aim of this study was to investigate the
epidemiology of
The use of volar locking compression plates for the treatment of
Although the outcome of
A total of 57 patients, aged between 23 and 86 years, with complex regional pain syndrome (CRPS) type 1 nine weeks after an isolated closed
The purpose of this study was to evaluate the
risk of late displacement after the treatment of distal radial fractures with
a locking volar plate, and to investigate the clinical and radiological
factors that might correlate with re-displacement. From March 2007
to October 2009, 120 of an original cohort of 132 female patients
with unstable
The aims of this study were to assess the efficacy
of a newly designed radiological technique (the radial groove view)
for the detection of protrusion of screws in the groove for the
extensor pollicis longus tendon (EPL) during plating of distal radial
fractures. We also aimed to determine the optimum position of the
forearm to obtain this view. We initially analysed the anatomy of
the EPL groove by performing three-dimensional CT on 51 normal forearms.
The mean horizontal angle of the groove was 17.8° (14° to 23°).
We found that the ideal position of the fluoroscopic beam to obtain
this view was 20° in the horizontal plane and 5° in the sagittal
plane. We then intra-operatively assessed the use of the radial groove
view for detecting protrusion of screws in the EPL groove in 93
fractures that were treated by volar plating. A total of 13 protruding
screws were detected. They were changed to shorter screws and these
patients underwent CT scans of the wrist immediately post-operatively.
There remained one screw that was protruding. These findings suggest
that the use of the radial groove view intra-operatively is a good
method of assessing the possible protrusion of screws into the groove
of EPL when plating a
The results of the DRAFFT (distal radius acute
fracture fixation trial) study, which compared volar plating with
Kirschner (K-) wire fixation for dorsally displaced