Advertisement for orthosearch.org.uk
Results 1 - 50 of 292
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 1009 - 1014
1 Aug 2019
Ramoutar DN Lefaivre K Broekhuyse H Guy P O’Brien P

Aims. The aim of this study was to determine the trajectory of recovery following fixation of tibial plateau fractures up to five-year follow-up, including simple (Schatzker I-IV) versus complex (Schatzker V-VI) fractures. Patients and Methods. Patients undergoing open reduction and internal fixation (ORIF) for tibial plateau fractures were enrolled into a prospective database. Functional outcome, using the 36-Item Short Form Health Survey Physical Component Summary (SF-36 PCS), was collected at baseline, six months, one year, and five years. The trajectory of recovery for complex fractures (Schatzker V and VI) was compared with simple fractures (Schatzker I to IV). Minimal clinically important difference (MCID) was calculated between timepoints. In all, 182 patients were enrolled: 136 (74.7%) in simple and 46 (25.3%) in complex. There were 103 female patients and 79 male patients with a mean age of 45.8 years (15 to 86). Results. Mean SF-36 PCS improved significantly in both groups from six to 12 months (p < 0.001) and one to five years (simple, p = 0.008; complex, p = 0.007). In both groups, the baseline scores were not reached at five years. The SF-36 PCS was significantly higher in the simple group compared with the complex group at both six months (p = 0.007) and 12 months (p = 0.01), but not at five years (p = 0.17). Between each timepoint, approximately 50% or more of the patients in each group achieved an MCID in their score change, indicating a significant clinical change in condition. The complex group had a much larger drop off in the first six months, with comparable proportions achieving MCID at the subsequent time intervals. Conclusion. Tibial plateau fracture recovery was characterized overall by an initial decline in functional outcome from baseline, followed by a steep improvement from six to 12 months, and ongoing recovery up to five years. In simple patterns, patients tended to achieve a higher functional score by six months compared with the complex patterns. However, comparable functional scores between the groups achieved only at the five-year point suggest later recovery in the complex group. Function does not improve to baseline by five years in either group. This information is useful in counselling patients about the course of prospective recovery. Cite this article: Bone Joint J 2019;101-B:1009–1014


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 632 - 637
1 May 2020
Gonzalez LJ Hildebrandt K Carlock K Konda SR Egol KA

Aims. Tibial plateau fractures are serious injuries about the knee that have the potential to affect patients’ long-term function. To our knowledge, this is the first study to use patient-reported outcomes (PROs) with a musculoskeletal focus to assess the long-term outcome, as compared to a short-term outcome baseline, of tibial plateau fractures treated using modern techniques. Methods. In total, 102 patients who sustained a displaced tibial plateau fracture and underwent operative repair by one of three orthopaedic traumatologists at a large, academic medical centre and had a minimum of five-year follow-up were identified. Breakdown of patients by Schatzker classification is as follows: two (1.9%) Schatzker I, 54 (50.9%) Schatzker II, two (1.9%) Schatzker III, 13 (12.3%) Schatzker IV, nine (8.5%) Schatzker V, and 26 (24.5%) Schatzker VI. Follow-up data obtained included: Visual Analogue Scale (VAS) or Numeric Rating Scale (NRS) pain scores, Short Musculoskeletal Functional Assessment (SMFA), and knee range of movement (ROM). Data at latest follow-up were then compared to 12-month data using a paired t-test. Results. Patient-reported functional outcomes as assessed by overall SMFA were statistically significantly improved at five years (p < 0.001) compared with one-year data from the same patients. Patients additionally reported an improvement in the Standardized Mobility Index (p < 0.001), Standardized Emotional Index (p < 0.001), as well as improvement in Standardized Bothersome Index (p = 0.003) between the first year and latest follow-up. Patient-reported pain and knee ROM were similar at five years to their one-year follow-up. In total, 15 of the patients had undergone subsequent orthopaedic surgery for their knees at the time of most recent follow-up. Of note, only one patient had undergone knee arthroplasty following plateau fixation related to post-traumatic osteoarthritis (OA). Conclusion. Knee pain following tibial plateau fracture stabilizes at one year. However, PROs continue to improve beyond one year following tibial plateau fracture, at least in a statistical sense, if not also clinically. Patients displayed statistical improvement across nearly all SMFA index scores at their minimum five-year follow-up compared with their one-year follow-up. Cite this article: Bone Joint J 2020;102-B(5):632–637


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1697 - 1702
1 Dec 2013
Maroto MD Scolaro JA Henley MB Dunbar RP

Bicondylar tibial plateau fractures result from high-energy injuries. Fractures of the tibial plateau can involve the tibial tubercle, which represents a disruption to the extensor mechanism and logically must be stabilised. The purpose of this study was to identify the incidence of an independent tibial tubercle fracture in bicondylar tibial plateau fractures, and to report management strategies and potential complications. We retrospectively reviewed a prospectively collected orthopaedic trauma database for the period January 2003 to December 2008, and identified 392 bicondylar fractures of the tibial plateau, in which 85 tibial tubercle fractures (21.6%) were identified in 84 patients. There were 60 men and 24 women in our study group, with a mean age of 45.4 years (18 to 71). In 84 fractures open reduction and internal fixation was undertaken, either with screws alone (23 patients) or with a plate and screws (61 patients). The remaining patient was treated non-operatively. In all, 52 fractures were available for clinical and radiological assessment at a mean follow-up of 58.5 weeks (24 to 94). All fractures of the tibial tubercle united, but 24 of 54 fractures (46%) required a secondary procedure for their tibial plateau fracture. Four patients reported pain arising from prominent tubercle plates and screws, which in one patient required removal. Tibial tubercle fractures occurred in over one-fifth of the bicondylar tibial plateau fractures in our series. Fixation is necessary and can be reliably performed with screws alone or with a screw and plate, which restores the extensor mechanism and facilitates early knee flexion. Cite this article: Bone Joint J 2013;95-B:1697–1702


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 109 - 114
1 Jan 2015
Haller JM Holt DC McFadden ML Higgins TF Kubiak EN

The aim of this study was to report the incidence of arthrofibrosis of the knee and identify risk factors for its development following a fracture of the tibial plateau. We carried out a retrospective review of 186 patients (114 male, 72 female) with a fracture of the tibial plateau who underwent open reduction and internal fixation. Their mean age was 46.4 years (19 to 83) and the mean follow-up was16.0 months (6 to 80). A total of 27 patients (14.5%) developed arthrofibrosis requiring a further intervention. Using multivariate regression analysis, the use of a provisional external fixator (odds ratio (OR) 4.63, 95% confidence interval (CI) 1.26 to 17.7, p = 0.021) was significantly associated with the development of arthrofibrosis. Similarly, the use of a continuous passive movement (CPM) machine was associated with significantly less development of arthrofibrosis (OR = 0.32, 95% CI 0.11 to 0.83, p = 0.024). The effect of time in an external fixator was found to be significant, with each extra day of external fixation increasing the odds of requiring manipulation under anaesthesia (MUA) or quadricepsplasty by 10% (OR = 1.10, p = 0.030). High-energy fracture, surgical approach, infection and use of tobacco were not associated with the development of arthrofibrosis. Patients with a successful MUA had significantly less time to MUA (mean 2.9 months; . sd. 1.25) than those with an unsuccessful MUA (mean 4.86 months;. sd. 2.61, p = 0.014). For those with limited movement, therefore, performing an MUA within three months of the injury may result in a better range of movement. . Based our results, CPM following operative fixation for a fracture of the tibial plateau may reduce the risk of the development of arthrofibrosis, particularly in patients who also undergo prolonged provisional external fixation. Cite this article: Bone Joint J 2015;97-B:109–14


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 861 - 867
1 Jul 2020
Hiranaka T Yoshikawa R Yoshida K Michishita K Nishimura T Nitta S Takashiba K Murray D

Aims. Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture, particularly in Japanese patients. The aim of this multicentre study was to determine when cementless tibial components could safely be used in Japanese patients based on the size and shape of the tibia. Methods. The study involved 212 cementless Oxford UKAs which were undertaken in 174 patients in six hospitals. The medial eminence line (MEL), which is a line parallel to the tibial axis passing through the tip of medial intercondylar eminence, was drawn on preoperative radiographs. Knees were classified as having a very overhanging medial tibial condyle if this line passed medial to the medial tibial cortex. They were also classified as very small if a size A/AA tibial component was used. Results. The overall rate of fracture was 8% (17 out of 212 knees). The rate was higher in knees with very overhanging condyles (Odds ratio (OR) 13; p < 0.001) and with very small components (OR 7; p < 0.001). The OR was 21 (p < 0.001) in those with both very overhanging condyles and very small components. In all, 69% of knees (147) had neither very overhanging nor very small components, and the fracture rate in these patients was 1.4% (2 out of 147 knees). Males had a significantly reduced risk of fracture (OR 0.13; p = 0.002), probably because no males required very small components and females were more likely to have very overhanging condyles (OR 3; p = 0.013). 31% of knees (66) were in males and in these the rate of fracture was 1.5% (1 out of 66 knees). Conclusion. The rate of tibial plateau fracture in Japanese patients undergoing cementless UKA is high. We recommend that cemented tibial fixation should be used in Japanese patients who require very small components or have very overhanging condyles, as identified from preoperative radiographs. In the remaining 69% of knees cementless fixation can be used. This approach should result in a low rate of fracture. Cite this article: Bone Joint J 2020;102-B(7):861–867


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1693 - 1697
1 Dec 2015
Keightley AJ Nawaz SZ Jacob JT Unnithan A Elliott DS Khaleel A

This study aimed to determine the long-term functional, clinical and radiological outcomes in patients with Schatzker IV to VI fractures of the tibial plateau treated with an Ilizarov frame. Clinical, functional and radiological assessment was carried out at a minimum of one year post-operatively. A cohort of 105 patients (62 men, 43 women) with a mean age of 49 years (15 to 87) and a mean follow-up of 7.8 years (1 to 19) were reviewed. There were 18 type IV, 10 type V and 77 type VI fractures. All fractures united with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient developed a deep infection. The median range of movement (ROM) of the knee was 110. o. and the median Iowa score was 85. . Our study demonstrates good long-term functional outcome with no deep infection; spanning the knee had no detrimental effect on the ROM or functional outcome. . High-energy fractures of the tibial plateau may be treated effectively with a fine wire Ilizarov fixator. Cite this article: Bone Joint J 2015;97-B:1693–7


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1233 - 1236
1 Sep 2005
Gaston P Will EM Keating JF

We assessed the functional outcome following fracture of the tibial plateau in 63 consecutive patients. Fifty-one patients were treated by internal fixation, five by combined internal and external fixation and seven non-operatively. Measurements of joint movement and muscle function were made using a muscle dynamometer at three, six and 12 months following injury. Thirteen patients (21%) had a residual flexion contracture at one year. Only nine (14%) patients achieved normal quadriceps muscle strength at 12 months, while 19 (30%) achieved normal hamstring muscle strength. Recovery was significantly slower in patients older than 40 years of age. We conclude that there is significant impairment of movement and muscle function after fracture of the tibial plateau and that the majority of patients have not fully recovered one year after injury


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 983 - 988
1 Sep 2003
Satku K Kumar VP Chong SM Thambyah A

The natural history of spontaneous osteonecrosis of the medial tibial plateau remains controversial and incomplete. We have studied 21 patients (aged between 53 and 77 years) with clinical and scintigraphic features of spontaneous osteonecrosis of the medial tibial plateau who were observed prospectively for at least three years (37 months to 8.5 years). The mean duration of follow-up was 5.6 years. The mean duration of symptoms at presentation was 4.7 weeks (3 days to 12 weeks). Radiographs of the affected knee at the first visit were normal in 15 patients and mildly arthritic in six. The characteristic radiographic lesion of osteonecrosis was noted at presentation in five of the mildly arthritic knees and during the evolution of the disease in eight of the radiographically normal knees. During the follow-up, subchondral sclerosis of the affected medial tibial plateau was noted in 16 knees. There are three distinct patterns of outcome: 1) acute extensive collapse of the medial tibial plateau in two knees within three months of onset; 2) rapid progression to varying degrees of osteoarthritis in 12 knees, in eight within a year, in all within two years and deterioration of the pre-existing osteoarthritis in three; and 3) complete resolution in four knees, two of which were normal at presentation and two mildly osteoarthritic. The two patients with acute extensive collapse and three who had rapid progression to severe osteoarthritis required total knee arthroplasty. We conclude that osteonecrosis of the medial tibial plateau progresses in most cases to significant degenerative disease of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 4 | Pages 575 - 578
1 Nov 1981
Scotland T Wardlaw D

A series of 29 patients with fractures of the tibial plateau were treated by means of a cast-brace. There were seven wedge fractures of the lateral tibial condyle, two dicondylar fractures and 20 compression fractures involving the lateral tibial plateau. The seven patients with wedge fractures were treated by skin or skeletal traction, followed as soon as possible by flexion exercises for the knee. Cast-braces were applied to all fractures as soon as possible after injury, and the patients allowed to bear weight freely. Early restoration of function of the injured limb was thereby achieved. The results of our study over a period of two and a half years indicate that cast-bracing is a very satisfactory method of treating fractures of the tibial plateau. All the fractures united, the movements and control of the knee were excellent, and valgus or varus deformity was unchanged before application and after removal of the brace


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 28 - 37
1 Jan 2024
Gupta S Sadczuk D Riddoch FI Oliver WM Davidson E White TO Keating JF Scott CEH

Aims. This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of tibial plateau fractures (TPFs) in older adults. Methods. This is a retrospective cohort study of 182 displaced TPFs in 180 patients aged ≥ 60 years, over a 12-year period with a minimum follow-up of one year. The mean age was 70.7 years (SD 7.7; 60 to 89), and 139/180 patients (77.2%) were female. Radiological assessment consisted of fracture classification; pre-existing knee osteoarthritis (OA); reduction quality; loss of reduction; and post-traumatic OA. Fracture depression was measured on CT, and the volume of defect estimated as half an oblate spheroid. Operative management, complications, reoperations, and mortality were recorded. Results. Nearly half of the fractures were Schatzker II AO B3.1 fractures (n = 85; 47%). Radiological knee OA was present at fracture in 59/182 TPFs (32.6%). Primary management was fixation in 174 (95.6%) and acute TKA in eight (4.4%). A total of 13 patients underwent late TKA (7.5%), most often within two years. By five years, 21/182 12% (95% confidence interval (CI) 6.0 to 16.7) had required TKA. Larger volume defects of greater depth on CT (median 15.9 mm vs 9.4 mm; p < 0.001) were significantly associated with TKA requirement. CT-measured joint depression of > 12.8 mm was associated with TKA requirement (area under the curve (AUC) 0.766; p = 0.001). Severe joint depression of > 15.5 mm (hazard ratio (HR) 6.15 (95% CI 2.60 to 14.55); p < 0.001) and pre-existing knee OA (HR 2.70 (95% CI 1.14 to 6.37); p = 0.024) were independently associated with TKA requirement. Where patients with severe joint depression of > 15.5 mm were managed with fixation, 11/25 ultimately required TKA. Conclusion. Overall, 12% of patients aged ≥ 60 years underwent TKA within five years of TPF. Severe joint depression and pre-existing knee arthritis were independent risk factors for both post-traumatic OA and TKA. These features should be investigated as potential indications for acute TKA in older adults with TPFs. Cite this article: Bone Joint J 2024;106-B(1):28–37


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 426 - 433
1 Apr 2009
Musahl V Tarkin I Kobbe P Tzioupis C Siska PA Pape H

The operative treatment of displaced fractures of the tibial plateau is challenging. Recent developments in the techniques of internal fixation, including the development of locked plating and minimal invasive techniques have changed the treatment of these fractures. We review current surgical approaches and techniques, improved devices for internal fixation and the clinical outcome after utilisation of new methods for locked plating


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1227 - 1232
1 Sep 2005
Brouwer RW Bierma-Zeinstra SMA van Koeveringe AJ Verhaar JAN

Our aim was to compare the degree of patellar descent and alteration in angle of the inclination of the tibial plateau in lateral closing-wedge and medial opening-wedge high tibial osteotomy (HTO) in 51 consecutive patients with osteoarthritis of the medial compartment and varus malalignment. Patellar height was measured by the Insall-Salvati (IS) and the Blackburne-Peel (BP) ratios. The tibial inclination was determined by the Moore-Harvey (MH) method. Multivariate linear regression analysis was used to determine the influence of the type of HTO (closing vs opening wedge) on the post-operative patellar height or tibial inclination. The intra- and interobserver variability of these methods was determined before operation and at follow-up at one year. After an opening-wedge HTO the patellar height was significantly more decreased (mean post-operative difference: IS = 0.15; 95% confidence interval (CI) 0.06 to 0.23; BP = 0.11; 95% CI 0.05 to 0.18) compared with a closing-wedge HTO. The angle of tibial inclination differed significantly (mean post-operative difference MH = −6.40°; 95% CI −8.74 to −4.02) between the two HTO techniques, increasing after opening-wedge HTO and decreasing after closing-wedge HTO. There was no clinically-relevant difference in the intra- and interobserver variability of measurements of patellar height either before or after HTO


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 68 - 73
1 Jan 2003
Keating JF Hajducka CL Harper J

We used calcium-phosphate cement combined with minimal internal fixation to treat 49 fractures of the lateral tibial plateau. There were 25 split depression fractures, 22 pure depression fractures and two bicondylar fractures. Anatomical reduction was obtained in 38 fractures, satisfactory reduction in nine and imperfect reduction in two. Of 44 patients reviewed at one year, 33 were rated as having an excellent reduction. Functional outcome as measured by the Rasmussen score was good or excellent at six months in 92% (44/48) of patients and in 95% (42/44) at one year. Eight (16%) showed some loss of reduction of the plateau. In seven of these the loss of reduction was slight (< 3 mm) and no action was taken. One patient with a deep infection had gross loss of reduction and a poor functional outcome. Calcium-phosphate cement is a useful alternative to bone grafting for the treatment of fractures of the tibial plateau


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 691 - 699
1 Jul 2003
Ali AM Burton M Hashmi M Saleh M

Fine-wire accepted as a minimally external fixation is invasive technique, which can provide better outcomes than traditional open methods in the management of complex fractures of the tibial plateau. Available fixators vary in their biomechanical stability, and we believe that a stable beam-loading system is essential for consistently good outcomes. We assessed, prospectively, the clinical, radiological and general health status of 20 of 21 consecutive patients with complex fractures of the tibial plateau who had been treated using a standard protocol, with percutaneous screw fixation and a neutralisation concept with a fine wire beam-loading fixator allowing early weight-bearing. Bony union was achieved in all patients, with 85% having good or excellent results. Full weight-bearing started during the first six weeks in 60% of patients. The general health status assessment correlated well with the knee scores and reflected a satisfactory outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 488 - 490
1 May 1994
Vangsness C Ghaderi B Hohl M Moore T

We examined 36 consecutive patients with closed tibial plateau fractures under anaesthesia and by diagnostic and operative arthroscopy before treating them by closed or open reduction and internal fixation. Following the principle of Hohl (1967) (Fig. 1) there were 9 minimally displaced fractures (type I), 6 with local depression (type II), 13 with split depression (type III), 7 with total condylar depression (type IV), and one bicondylar comminuted upper tibial fracture (type V). Seventeen (47%) of knees were found to have associated meniscal injuries which required surgical treatment; five repairs and 12 partial meniscectomies. Neither the type of plateau fracture nor the presence or absence of ligament injury correlated with meniscal tear. There were no intraoperative or postoperative complications from arthroscopy


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 2 | Pages 256 - 262
1 May 1972
Kay NRM Martins HD

1. Thirty-nine patients with rheumatoid arthritis who had had a MacIntosh tibial plateau hemiarthroplasty are reviewed. 2. From the clinical findings it is possible to suggest a basis for the selection of suitable patients for the procedure. 3. Eighty-five per cent of the patients obtained relief of pain with good function of the knee. 4. The complications were infection and instability of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 84 - 88
1 Jan 1987
Dias J Stirling A Finlay D Gregg P

Sixteen consecutive patients with tibial plateau fractures were investigated by standard radiography, biplanar tomography and computerised axial tomograms (CT scans). It was found that CT scanning proved most helpful for classifying the type of fracture, for evaluating the degree of comminution, and for measuring displacement. Moreover, because a single position was maintained throughout the investigation, the patients felt less discomfort than during other assessment procedures. For these reasons CT scanning is recommended for evaluating this type of fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 49 - 52
1 Jan 1990
Jensen D Rude C Duus B Bjerg-Nielsen A

We evaluated the long-term results of 109 tibial plateau fractures, 61 treated by skeletal traction and early knee movement and 48 treated by surgery, at an average follow-up of 70 months. The functional results were much the same, though meniscectomy had been performed in almost half of the surgical patients. Time in bed and duration of hospital stay were clearly shorter after surgery (p less than 0.0001). We concluded that conservative management is a valid alternative to surgery, but should probably be reserved for cases where operation is undesirable. Future studies should compare surgery without meniscectomy and conservative treatment using cast braces to reduce the time in traction


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 817 - 823
1 Jun 2011
Solomon LB Callary SA Stevenson AW McGee MA Chehade MJ Howie DW

We investigated the stability of seven Schatzker type II fractures of the lateral tibial plateau treated by subchondral screws and a buttress plate followed by immediate partial weight-bearing. In order to assess the stability of the fracture, weight-bearing inducible displacements of the fracture fragments and their migration over a one-year period were measured by differentially loaded radiostereometric analysis and standard radiostereometric analysis, respectively. The mean inducible craniocaudal fracture fragment displacements measured −0.30 mm (−0.73 to 0.02) at two weeks and 0.00 mm (−0.12 to 0.15) at 52 weeks. All inducible displacements were elastic in nature under all loads at each examination during follow-up. At one year, the mean craniocaudal migration of the fracture fragments was −0.34 mm (−1.64 to 1.51). Using radiostereometric methods, this case series has shown that in the Schatzker type II fractures investigated, internal fixation with subchondral screws and a buttress plate provided adequate stability to allow immediate post-operative partial weight-bearing, without harmful consequences


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 478 - 480
1 May 1999
Parker PJ Tepper KB Brumback RJ Novak VP Belkoff SM

Type-I fractures of the lateral tibial plateau were simulated by osteotomy in 18 pairs of unembalmed cadaver tibiae. One fracture of each pair was fixed with two lag screws whereas the contralateral site was stabilised with three lag screws, or two lag screws plus an antiglide screw. The lateral plateau was displaced downwards using a servohydraulic materials testing machine and the resulting force and articular surface gap were recorded. Yield load was defined as the maximum load needed to create a 2.0 mm articular offset at the fracture line. The yield loads of the three-lag-screw (307 ± 240 N) and antiglide constructs (342 ± 249 N) were not significantly different from their two-screw control constructs (231 ± 227 and 289 ± 245 N, respectively). We concluded that adding an antiglide screw or a third lag screw did not provide any biomechanical advantage in stabilising these fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 285 - 289
1 Mar 1994
Georgiadis G

We report the use of combined anterior and posterior approaches for the reduction and fixation of complex tibial plateau fractures involving a large split posteromedial fragment. In four patients, we used a posterior plate to fix the posteromedial fragment. All fractures united in good position with no significant complications, and all patients had a good range of knee movement. This technique should be considered for complex fractures in which there is a substantial posteromedial fragment (split) component


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 710 - 717
1 Sep 1996
Dendrinos GK Kontos S Katsenis D Dalas A

We treated 24 patients with high-energy fractures of the tibial plateau by the Ilizarov fixator and transfixion wires. Eleven fractures were open, and 20 patients had complex injuries. Twelve were treated by ligamentotaxis and percutaneous fixation, seven by limited open reduction and five by extensive open reduction. All were followed for at least 24 months. All the fractures united, with an average time to healing of 14.4 weeks. Thirteen patients achieved full extension and 13 more than 110° of flexion. Twenty-two knees were stable. Fifteen patients walked normally and the rest with only a slight limp. All but two knees had an articular step-off of less than 4 mm and all had normal axial alignment except two. There were no cases of postoperative skin infection, osteomyelitis or septic arthritis. Ilizarov circular fixation is an ideal method of treatment for these fractures when extensive dissection and internal fixation are contraindicated due to trauma to the soft tissue, deficiency of bone stock, and bony comminution


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 959 - 964
1 Nov 1998
Scheerlinck T Ng CS Handelberg F Casteleyn PP

We carried out percutaneous, arthroscopically- and fluoroscopically-assisted osteosynthesis of fractures of the tibial plateau in 52 patients, of whom 38 were assessed using the HSS knee score and standing radiographs. We reviewed 31 AO type-B fractures and seven type-C fractures after a mean follow-up of five years (1 to 14). Fixation was achieved using percutaneous screws and/or an external frame; 33 associated intra-articular injuries, diagnosed in 21 out of the 38 patients, were treated arthroscopically. Subjectively, 94.7% of the patients reviewed were satisfied. According to the HSS knee score 78.9% of the results were excellent, 13.2% good, 7.9% fair and none was poor. Narrowing of the joint space was found in 28.9% of the injured and 5.3% of the unaffected knees and axial deviation of 5° to 10° in 15.8% of the injured and 10.5% of the unaffected knees. Of the 52 fractures, reduction was incomplete in one, and in two secondary displacement occurred, of which one required corrective osteotomy. Deep-venous thrombosis occurred in four cases. The technique has proved to be safe but demanding. It facilitates diagnosis and appropriate treatment of associated intra-articular lesions


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 290 - 292
1 Mar 1994
Vanek J

We report a case of an apparent avulsion fracture of the posteromedial margin of the medial plateau of the tibia. This was associated with a tear of the medial meniscus and rupture of the anterior cruciate ligament (ACL). This triad has been previously reported, and the plateau fracture was related to the insertion of the semimembranosus tendon. The detailed investigation of our case and some experiments on cadaver knees showed that the injury was not an avulsion fracture but was produced by varus and external rotation forces on a flexed knee. It was due to the anterior subluxation of the medial tibial plateau after rupture of the ACL


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 330 - 333
1 Mar 2008
Lankester BJA Cottam HL Pinskerova V Eldridge JDJ Freeman MAR

From a search of MRI reports on knees, 20 patients were identified with evidence of early anteromedial osteoarthritis without any erosion of bone and a control group of patients had an acute rupture of the anterior cruciate ligament. The angle formed between the extension and flexion facets of the tibia, which is known as the extension facet angle, was measured on a sagittal image at the middle of the medial femoral condyle.

The mean extension facet angle in the control group was 14° (3° to 25°) and was unrelated to age (Spearman’s rank coefficient, p = 0.30, r = 0.13). The mean extension facet angle in individuals with MRI evidence of early anteromedial osteoarthritis was 19° (13° to 26°, SD 4°). This difference was significant (Mann-Whitney U test, p < 0.001).

A wide variation in the extension facet angle was found in the normal control knees and an association between an increased extension facet angle and MRI evidence of early anteromedial osteoarthritis. Although a causal link has not been demonstrated, we postulate that a steeper extension facet angle might increase the duration of loading on the extension facet during the stance phase of gait, and that this might initiate failure of the articular cartilage.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 3 | Pages 336 - 339
1 Jun 1982
Struben P

The suggestion that the knee behaves like a closed kinematic chain has been tested experimentally. The tibial joint surfaces were replaced by a deformable material and new surfaces were moulded by flexion and extension of the knee. The results support the closed kinematic chain theory; the newly moulded joint surfaces strikingly resemble the original joint surfaces. Inferences are drawn to explain why a fracture of the tibial condyle will remould with early mobilisation of the knee; why a jerk is elicited in tests for anterolateral instability; and why a flexion-compression force alone is unlikely to damage the menisci.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 1005 - 1005
1 Nov 1991
Thomas M Schofield C Unwin A


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 463 - 463
1 Apr 2000
TAN JW


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 152 - 153
1 Jan 2000
EARNSHAW S


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 1088 - 1088
1 Sep 2003
LERNER A HORESH Z


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 320 - 320
1 Mar 1989
Sharif D Braddock G


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1118 - 1125
4 Oct 2022
Suda Y Hiranaka T Kamenaga T Koide M Fujishiro T Okamoto K Matsumoto T

Aims. A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting. Methods. This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide. Anterior and posterior KCDs and the origins of fracture lines were assessed using 3D CT scans one week postoperatively. The KCDs and rate of fracture were compared between the two groups. Results. Medial tibial fractures occurred after surgery in 15 patients (15 OUKAs) in the conventional group, but only one patient (one OUKA) had a tibial fracture after surgery in the varus group. This difference was significant (6.9% vs 1.1%; p = 0.029). The mean posterior KCD was significantly shorter in the conventional group (5.0 mm (SD 1.7)) than in the varus group (6.1 mm (SD 2.1); p = 0.002). Conclusion. In OUKA, the distance between the keel and posterior tibial cortex was longer in our patients with slight varus alignment of the tibial component, which seems to decrease the risk of postoperative tibial fracture. Cite this article: Bone Joint J 2022;104-B(10):1118–1125


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 836 - 841
1 Jun 2015
Jónsson BY Mjöberg B

A total of 20 patients with a depressed fracture of the lateral tibial plateau (Schatzker II or III) who would undergo open reduction and internal fixation were randomised to have the metaphyseal void in the bone filled with either porous titanium granules or autograft bone. Radiographs were undertaken within one week, after six weeks, three months, six months, and after 12 months. The primary outcome measure was recurrent depression of the joint surface: a secondary outcome was the duration of surgery. The risk of recurrent depression of the joint surface was lower (p < 0.001) and the operating time less (p < 0.002) when titanium granules were used. The indication is that it is therefore beneficial to use porous titanium granules than autograft bone to fill the void created by reducing a depressed fracture of the lateral tibial plateau. There is no donor site morbidity, the operating time is shorter and the risk of recurrent depression of the articular surface is less. . Cite this article: Bone Joint J 2015; 97-B:836–41


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 532 - 538
1 Apr 2015
Scott CEH Davidson E MacDonald DJ White TO Keating JF

Radiological evidence of post-traumatic osteoarthritis (PTOA) after fracture of the tibial plateau is common but end-stage arthritis which requires total knee arthroplasty is much rarer. The aim of this study was to examine the indications for, and outcomes of, total knee arthroplasty after fracture of the tibial plateau and to compare this with an age and gender-matched cohort of TKAs carried out for primary osteoarthritis. Between 1997 and 2011, 31 consecutive patients (23 women, eight men) with a mean age of 65 years (40 to 89) underwent TKA at a mean of 24 months (2 to 124) after a fracture of the tibial plateau. Of these, 24 had undergone ORIF and seven had been treated non-operatively. Patients were assessed pre-operatively and at 6, 12 and > 60 months using the Short Form-12, Oxford Knee Score and a patient satisfaction score. Patients with instability or nonunion needed total knee arthroplasty earlier (14 and 13.3 months post-injury) than those with intra-articular malunion (50 months, p < 0.001). Primary cruciate-retaining implants were used in 27 (87%) patients. Complication rates were higher in the PTOA cohort and included wound complications (13% vs 1% p = 0.014) and persistent stiffness (10% vs 0%, p = 0.014). Two (6%) PTOA patients required revision total knee arthroplasty at 57 and 114 months. The mean Oxford knee score was worse pre-operatively in the cohort with primary osteoarthritis (18 vs 30, p < 0.001) but there were no significant differences in post-operative Oxford knee score or patient satisfaction (primary osteoarthritis 86%, PTOA 78%, p = 0.437). Total knee arthroplasty undertaken after fracture of the tibial plateau has a higher rate of complications than that undertaken for primary osteoarthritis, but patient-reported outcomes and satisfaction are comparable. Cite this article: Bone Joint J 2015;97-B:532–8


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 172 - 179
1 Feb 2008
Pinczewski LA Salmon LJ Jackson WFM von Bormann RBP Haslam PG Tashiro S

There is little evidence examining the relationship between anatomical landmarks, radiological placement of the tunnels and long-term clinical outcomes following anterior cruciate ligament (ACL) reconstruction. The aim of this study was to investigate the reproducibility of intra-operative landmarks for placement of the tunnels in single-bundle reconstruction of the ACL using four-strand hamstring tendon autografts. Isolated reconstruction of the ACL was performed in 200 patients, who were followed prospectively for seven years with use of the International Knee Documentation Committee forms and radiographs. Taking 0% as the anterior and 100% as the posterior extent, the femoral tunnel was a mean of 86% (. sd. 5) along Blumensaat’s line and the tibial tunnel was 48% (. sd. 5) along the tibial plateau. Taking 0% as the medial and 100% as the lateral extent, the tibial tunnel was 46% (. sd. 3) across the tibial plateau and the mean inclination of the graft in the coronal plane was 19° (. sd. 5.5). The use of intra-operative landmarks resulted in reproducible placement of the tunnels and an excellent clinical outcome seven years after operation. Vertical inclination was associated with increased rotational instability and degenerative radiological changes, while rupture of the graft was associated with posterior placement of the tibial tunnel. If the osseous tunnels are correctly placed, single-bundle reconstruction of the ACL adequately controls both anteroposterior and rotational instability


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 53 - 58
1 Jan 2019
Billi F Kavanaugh A Schmalzried H Schmalzried TP

Aims. Loosening of the tibial component after total knee arthroplasty (TKA) is a common indication for revision. Increasing the strength of the initial tibial implant/cement interface is desirable. There is little information about the surgical techniques that lead to the highest strength. We investigated the effects of eight variables on the strength of the initial tibial baseplate/cement interface. Materials and Methods. A total of 48 tibial trays were cemented into acrylic holders using cement from two manufacturers, at three different times (early, normal, and late) using two techniques: cementing the tibial plateau or the plateau and the keel; and involving two conditions of contamination with marrow fat (at the metal/cement and cement/cement interfaces). Push-out tests were performed with load continuously recorded. Results. Compared with normal conditions, early cementing increased the mean strength of the interface when using the two cements, Simplex and Palacos, by 48% and 72%, respectively. Late cementing reduced the strength by 47% and 73%, respectively. Cementing the keel increased the mean strength by 153% and 147%, respectively, for the two cements. Contamination of the metal/cement interface with fat reduced the mean strength by 99% and 94% for the two cements but adding cement to the underside of the tibial tray prior to insertion resulted in the mean strength being lowered by only 65% and 43%, respectively. Conclusion. In order to maximize the strength of the tibial tray/cement interface, cement should be applied to the component soon after mixing, contamination of the interface should be avoided, and the keel and the plateau should be cemented


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1112 - 1116
1 Aug 2018
Sinha R Weigl D Mercado E Becker T Kedem P Bar-On E

Aims. Guided growth using eight-plates is commonly used for correction of angular limb deformities in growing children. The principle is of tethering at the physeal periphery while enabling growth in the rest of the physis. The method is also applied for epiphysiodesis to correct limb-length discrepancy (LLD). Concerns have been raised regarding the potential of this method to create an epiphyseal deformity. However, this has not been investigated. The purpose of this study was to detect and quantify the occurrence of deformities in the proximal tibial epiphysis following treatment with eight-plates. Patients and Methods. A retrospective study was performed including 42 children at a mean age of 10.8 years (3.7 to 15.7) undergoing eight-plate insertion in the proximal tibia for correction of coronal plane deformities or LLD between 2007 and 2015. A total of 64 plates were inserted; 48 plates (34 patients) were inserted to correct angular deformities and 16 plates (8 patients) for LLD. Medical records, Picture Archive and Communication System images, and conventional radiographs were reviewed. Measurements included interscrew angle, lateral and medial plateau slope angles measured between the plateau surface and the line between the ends of the physis, and tibial plateau roof angle defined as 180° minus the sum of both plateau angles. Measurements were compared between radiographs performed adjacent to surgery and those at latest follow-up, and between operated and non-operated plateaus. Statistical analysis was performed using BMDP Statistical Software. Results. Slope angle increased in 31 (49.2%) of operated epiphyses by a mean of 5° (1° to 23°) compared with 29 (31.9%) in non-operated epiphyses (p = 0.043). Roof angle decreased in 29 (46.0%) of operated tibias and in 25 (27.5%) of non-operated ones by a mean of 5° (1° to 18°) (p = 0.028). Slope angle change frequency was similar in patients with LLD, varus and valgus correction (p = 0.37) but roof angle changes were slightly more frequent in LLD (p = 0.059) and correlated with the change in inter screw angles (r = 0.74, p = 0.001). Conclusion. The use of eight-plates in the proximal tibia for deformity correction and limb-length equalization causes a change in the bony morphology of the tibial plateau in a significant number of patients and the effect is more pronounced in the correction of LLD. Cite this article: Bone Joint J 2018;100-B:1112–16


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 956 - 962
1 Jul 2014
Ahearn N Oppy A Halliday R Rowett-Harris J Morris SA Chesser TJ Livingstone JA

Unstable bicondylar tibial plateau fractures are rare and there is little guidance in the literature as to the best form of treatment. We examined the short- to medium-term outcome of this injury in a consecutive series of patients presenting to two trauma centres. Between December 2005 and May 2010, a total of 55 fractures in 54 patients were treated by fixation, 34 with peri-articular locking plates and 21 with limited access direct internal fixation in combination with circular external fixation using a Taylor Spatial Frame (TSF). At a minimum of one year post-operatively, patient-reported outcome measures including the WOMAC index and SF-36 scores showed functional deficits, although there was no significant difference between the two forms of treatment. Despite low outcome scores, patients were generally satisfied with the outcome. We achieved good clinical and radiological outcomes, with low rates of complication. In total, only three patients (5%) had collapse of the joint of > 4 mm, and metaphysis to diaphysis angulation of greater than 5º, and five patients (9%) with displacement of > 4 mm. All patients in our study went on to achieve full union. This study highlights the serious nature of this injury and generally poor patient-reported outcome measures following surgery, despite treatment by experienced surgeons using modern surgical techniques. Our findings suggest that treatment of complex bicondylar tibial plateau fractures with either a locking plate or a TSF gives similar clinical and radiological outcomes. Cite this article: Bone Joint J 2014;96-B:956–62


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 59 - 64
1 Jan 2014
Weston-Simons JS Pandit H Kendrick BJL Jenkins C Barker K Dodd CAF Murray DW

Mobile-bearing unicompartmental knee replacements (UKRs) with a flat tibial plateau have not performed well in the lateral compartment, owing to a high dislocation rate. This led to the development of the Domed Lateral Oxford UKR (Domed OUKR) with a biconcave bearing. The aim of this study was to assess the survival and clinical outcomes of the Domed OUKR in a large patient cohort in the medium term. We prospectively evaluated 265 consecutive knees with isolated disease of the lateral compartment and a mean age at surgery of 64 years (32 to 90). At a mean follow-up of four years (. sd. 2.2, (0.5 to 8.3)) the mean Oxford knee score was 40 out of 48 (. sd. 7.4). A total of 12 knees (4.5%) had re-operations, of which four (1.5%) were for dislocation. All dislocations occurred in the first two years. Two (0.8%) were secondary to significant trauma that resulted in ruptured ligaments, and two (0.8%) were spontaneous. In four patients (1.5%) the UKR was converted to a primary TKR. Survival at eight years, with failure defined as any revision, was 92.1% (95% confidence interval 81.3 to 100). . The Domed Lateral OUKR gives good clinical outcomes, low re-operation and revision rates and a low dislocation rate in patients with isolated lateral compartmental disease, in the hands of the designer surgeons. Cite this article: Bone Joint J 2014;96-B:59–64


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 1033 - 1040
1 Jul 2010
Nishino T Chang F Ishii T Yanai T Mishima H Ochiai N

We have previously shown that joint distraction and movement with a hinged external fixation device for 12 weeks was useful for repairing a large articular cartilage defect in a rabbit model. We have now investigated the results after six months and one year. The device was applied to 16 rabbits who underwent resection of the articular cartilage and subchondral bone from the entire tibial plateau. In group A (nine rabbits) the device was applied for six months. In group B (seven rabbits) it was in place for six months, after which it was removed and the animals were allowed to move freely for an additional six months. The cartilage remained sound in all rabbits. The areas of type II collagen-positive staining and repaired soft tissue were larger in group B than in group A. These findings provide evidence of long-term persistence of repaired cartilage with this technique and that weight-bearing has a positive effect on the quality of the cartilage


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 721 - 729
1 May 2005
Yanai T Ishii T Chang F Ochiai N

We produced large full-thickness articular cartilage defects in 33 rabbits in order to evaluate the effect of joint distraction and autologous culture-expanded bone-marrow-derived mesenchymal cell transplantation (ACBMT) at 12 weeks. After fixing the knee on a hinged external fixator, we resected the entire surface of the tibial plateau. We studied three groups: 1) with and without joint distraction; 2) with joint distraction and collagen gel, and 3) with joint distraction and ACBMT and collagen gel. The histological scores were significantly higher in the groups with ACBMT collagen gel (p < 0.05). The area of regenerated soft tissue was smaller in the group allowed to bear weight (p < 0.05). These findings suggest that the repair of large defects of cartilage can be enhanced by joint distraction, collagen gel and ACBMT


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 325 - 331
1 Mar 2014
Dodds AL Halewood C Gupte CM Williams A Amis AA

There have been differing descriptions of the anterolateral structures of the knee, and not all have been named or described clearly. The aim of this study was to provide a clear anatomical interpretation of these structures. We dissected 40 fresh-frozen cadaveric knees to view the relevant anatomy and identified a consistent structure in 33 knees (83%); we termed this the anterolateral ligament of the knee. This structure passes antero-distally from an attachment proximal and posterior to the lateral femoral epicondyle to the margin of the lateral tibial plateau, approximately midway between Gerdy’s tubercle and the head of the fibula. The ligament is superficial to the lateral (fibular) collateral ligament proximally, from which it is distinct, and separate from the capsule of the knee. In the eight knees in which it was measured, we observed that the ligament was isometric from 0° to 60° of flexion of the knee, then slackened when the knee flexed further to 90° and was lengthened by imposing tibial internal rotation. . Cite this article: Bone Joint J 2014;96-B:325–31


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 710 - 715
1 May 2005
van Huyssteen AL Hastings CJ Olesak M Hoffman EB

We reviewed 34 knees in 24 children after a double-elevating osteotomy for late-presenting infantile Blount’s disease. The mean age of patients was 9.1 years (7 to 13.5). All knees were in Langenskiöld stages IV to VI. The operative technique corrected the depression of the medial joint line by an elevating osteotomy, and the remaining tibial varus and internal torsion by an osteotomy just below the apophysis. In the more recent patients (19 knees), a proximal lateral tibial epiphysiodesis was performed at the same time. The mean pre-operative angle of depression of the medial tibial plateau of 49° (40° to 60°) was corrected to a mean of 26° (20° to 30°), which was maintained at follow-up. The femoral deformity was too small to warrant femoral osteotomy in any of our patients. The mean pre-operative mechanical varus of 30.6° (14° to 66°) was corrected to 0° to 5° of mechanical valgus in 29 knees. In five knees, there was an undercorrection of 2° to 5° of mechanical varus. At follow-up a further eight knees, in which lateral epiphysiodesis was delayed beyond five months, developed recurrent tibial varus associated with fusion of the medial proximal tibial physis


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1334 - 1340
1 Oct 2011
Nicholson JA Sutherland AG Smith FW

Abnormal knee kinematics following reconstruction of the anterior cruciate ligament may exist despite an apparent resolution of tibial laxity and functional benefit. We performed upright, weight-bearing MR scans of both knees in the sagittal plane at different angles of flexion to determine the kinematics of the knee following unilateral reconstruction (n = 12). The uninjured knee acted as a control. Scans were performed pre-operatively and at three and six months post-operatively. Anteroposterior tibial laxity was determined using an arthrometer and patient function by validated questionnaires before and after reconstruction. In all the knees with deficient anterior cruciate ligaments, the tibial plateau was displaced anteriorly and internally rotated relative to the femur when compared with the control contralateral knee, particularly in extension and early flexion (mean lateral compartment displacement: extension 7.9 mm (. sd 4.8), p = 0.002 and 30° flexion 5.1 mm (. sd.  3.6), p = 0.004). In all ten patients underwent post-operative scans. Reconstruction reduced the subluxation of the lateral tibial plateau at three months, with resolution of anterior displacement in early flexion, but not in extension (p = 0.015). At six months, the reconstructed knee again showed anterior subluxation in both the lateral (mean: extension 4.2 mm (sd 4.2), p = 0.021 and 30° flexion 3.2 mm (. sd. 3.3), p = 0.024) and medial compartments (extension, p = 0.049). . Our results show that despite improvement in laxity and functional benefit, abnormal knee kinematics remain at six months and actually deteriorate from three to six months following reconstruction of the anterior cruciate ligament


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 324 - 330
1 Mar 2006
Scarvell JM Smith PN Refshauge KM Galloway HR Woods KR

This prospective study used magnetic resonance imaging to record sagittal plane tibiofemoral kinematics before and after anterior cruciate ligament reconstruction using autologous hamstring graft. Twenty patients with anterior cruciate ligament injuries, performed a closed-chain leg-press while relaxed and against a 150 N load. The tibiofemoral contact patterns between 0° to 90° of knee flexion were recorded by magnetic resonance scans. All measurements were performed pre-operatively and repeated at 12 weeks and two years. Following reconstruction there was a mean passive anterior laxity of 2.1 mm (. sd. 2.3), as measured using a KT 1000 arthrometer, and the mean Cincinnati score was 90 (. sd. 11) of 100. Pre-operatively, the medial and lateral contact patterns of the injured knees were located posteriorly on the tibial plateau compared with the healthy contralateral knees (p = 0.014), but were no longer different at 12 weeks (p = 0.117) or two years postoperatively (p = 0.909). However, both reconstructed and healthy contralateral knees showed altered kinematics over time. At two years, the contact pattern showed less posterior translation of the lateral femoral condyle during flexion (p < 0.01)


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 499 - 505
1 May 2000
Uvehammer J Kärrholm J Brandsson S

We studied the kinetics of the knee in 20 patients (22 knees) 12 months after total knee arthroplasty (TKA), by using three-dimensional radiostereometry and film-exchanger techniques. Eleven knees had a concave (constrained) tibial implant and 11 a posterior-stabilised prosthesis. Eleven normal knees served as a control group. In the posterior-stabilised knees there was less proximal and posterior displacement of the centre of the tibial plateau during extension from 45° to 15°, with a decrease in the anterior translation of the femoral condyles of 4 mm at 45°. There was less internal tibial rotation and increased distal positioning of the centre of the tibial plateau with both designs when compared with the normal knees, and in both the centre of the plateau was displaced posteriorly by more than 1 cm. Increased AP translation has been recorded in all prosthetic designs so far studied by radiostereometry. The use of a posterior-stabilised design of tibial insert could reduce this translation but not to that of the normal knee


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1111 - 1115
1 Nov 2001
Nakamura E Mizuta H Kudo S Takagi K Sakamoto K

Conventional high tibial osteotomy for osteoarthritis of the medial compartment of the knee with closed-wedge or dome osteotomy (DMO) may produce shortening of the patellar tendon and loss of inclination of the proximal tibial plateau or of the offset of the tibial condyle relative to its bony axis. This can make subsequent total knee arthroplasty technically demanding. We undertook a prospective study comparing these changes after DMO with those after using open-wedge osteotomy hemicallotasis (HCO). A total of 50 knees with arthritis of the medial compartment in 46 consecutive patients was randomly allocated to either DMO or HCO. There were no significant differences between the groups with regard to age, gender, femorotibial angle before operation or the angle of correction. Radiological studies showed that HCO caused little change in the length of the patellar tendon or the inclination angle of the tibial plateau, while after DMO both gradually decreased. The degree of tibial condylar offset increased in both groups, but less so in the HCO group


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 277 - 283
1 Mar 2023
Gausden EB Puri S Chiu Y Figgie MP Sculco TP Westrich G Sculco PK Chalmers BP

Aims

The purpose of this study was to assess mid-term survivorship following primary total knee arthroplasty (TKA) with Optetrak Logic components and identify the most common revision indications at a single institution.

Methods

We identified a retrospective cohort of 7,941 Optetrak primary TKAs performed from January 2010 to December 2018. We reviewed the intraoperative findings of 369 TKAs that required revision TKA from January 2010 to December 2021 and the details of the revision implants used. Kaplan-Meier analysis was used to determine survivorship. Cox regression analysis was used to examine the impact of patient variables and year of implantation on survival time.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 56 - 63
1 Jan 2023
de Klerk HH Oosterhoff JHF Schoolmeesters B Nieboer P Eygendaal D Jaarsma RL IJpma FFA van den Bekerom MPJ Doornberg JN

Aims

This study aimed to answer the following questions: do 3D-printed models lead to a more accurate recognition of the pattern of complex fractures of the elbow?; do 3D-printed models lead to a more reliable recognition of the pattern of these injuries?; and do junior surgeons benefit more from 3D-printed models than senior surgeons?

Methods

A total of 15 orthopaedic trauma surgeons (seven juniors, eight seniors) evaluated 20 complex elbow fractures for their overall pattern (i.e. varus posterior medial rotational injury, terrible triad injury, radial head fracture with posterolateral dislocation, anterior (trans-)olecranon fracture-dislocation, posterior (trans-)olecranon fracture-dislocation) and their specific characteristics. First, fractures were assessed based on radiographs and 2D and 3D CT scans; and in a subsequent round, one month later, with additional 3D-printed models. Diagnostic accuracy (acc) and inter-surgeon reliability (κ) were determined for each assessment.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1271 - 1278
1 Dec 2023
Rehman Y Korsvold AM Lerdal A Aamodt A

Aims

This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS).

Methods

Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed.