This study aimed to determine the long-term functional,
clinical and radiological outcomes in patients with Schatzker IV
to VI fractures of the
Bicondylar
Aims. The aim of this study was to determine the trajectory of recovery following fixation of
The aim of this study was to report the incidence
of arthrofibrosis of the knee and identify risk factors for its development
following a fracture of the
Aims.
Aims. Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of
We assessed the functional outcome following fracture of the
The natural history of spontaneous osteonecrosis of the medial
A series of 29 patients with fractures of the
Aims. This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of
The operative treatment of displaced fractures of the
Our aim was to compare the degree of patellar descent and alteration in angle of the inclination of the
We used calcium-phosphate cement combined with minimal internal fixation to treat 49 fractures of the lateral
Fine-wire accepted as a minimally external fixation is invasive technique, which can provide better outcomes than traditional open methods in the management of complex fractures of the
We examined 36 consecutive patients with closed
1. Thirty-nine patients with rheumatoid arthritis who had had a MacIntosh
Sixteen consecutive patients with
We evaluated the long-term results of 109
We investigated the stability of seven Schatzker type II fractures of the lateral
Type-I fractures of the lateral
We report the use of combined anterior and posterior approaches for the reduction and fixation of complex
We treated 24 patients with high-energy fractures of the
We carried out percutaneous, arthroscopically- and fluoroscopically-assisted osteosynthesis of fractures of the
We report a case of an apparent avulsion fracture of the posteromedial margin of the medial plateau of the tibia. This was associated with a tear of the medial meniscus and rupture of the anterior cruciate ligament (ACL). This triad has been previously reported, and the plateau fracture was related to the insertion of the semimembranosus tendon. The detailed investigation of our case and some experiments on cadaver knees showed that the injury was not an avulsion fracture but was produced by varus and external rotation forces on a flexed knee. It was due to the anterior subluxation of the medial
From a search of MRI reports on knees, 20 patients were identified with evidence of early anteromedial osteoarthritis without any erosion of bone and a control group of patients had an acute rupture of the anterior cruciate ligament. The angle formed between the extension and flexion facets of the tibia, which is known as the extension facet angle, was measured on a sagittal image at the middle of the medial femoral condyle. The mean extension facet angle in the control group was 14° (3° to 25°) and was unrelated to age (Spearman’s rank coefficient, p = 0.30, r = 0.13). The mean extension facet angle in individuals with MRI evidence of early anteromedial osteoarthritis was 19° (13° to 26°, SD 4°). This difference was significant (Mann-Whitney U test, p <
0.001). A wide variation in the extension facet angle was found in the normal control knees and an association between an increased extension facet angle and MRI evidence of early anteromedial osteoarthritis. Although a causal link has not been demonstrated, we postulate that a steeper extension facet angle might increase the duration of loading on the extension facet during the stance phase of gait, and that this might initiate failure of the articular cartilage.
The suggestion that the knee behaves like a closed kinematic chain has been tested experimentally. The tibial joint surfaces were replaced by a deformable material and new surfaces were moulded by flexion and extension of the knee. The results support the closed kinematic chain theory; the newly moulded joint surfaces strikingly resemble the original joint surfaces. Inferences are drawn to explain why a fracture of the tibial condyle will remould with early mobilisation of the knee; why a jerk is elicited in tests for anterolateral instability; and why a flexion-compression force alone is unlikely to damage the menisci.
Aims. A fracture of the medial
A total of 20 patients with a depressed fracture
of the lateral
Radiological evidence of post-traumatic osteoarthritis
(PTOA) after fracture of the
There is little evidence examining the relationship between anatomical landmarks, radiological placement of the tunnels and long-term clinical outcomes following anterior cruciate ligament (ACL) reconstruction. The aim of this study was to investigate the reproducibility of intra-operative landmarks for placement of the tunnels in single-bundle reconstruction of the ACL using four-strand hamstring tendon autografts. Isolated reconstruction of the ACL was performed in 200 patients, who were followed prospectively for seven years with use of the International Knee Documentation Committee forms and radiographs. Taking 0% as the anterior and 100% as the posterior extent, the femoral tunnel was a mean of 86% (. sd. 5) along Blumensaat’s line and the tibial tunnel was 48% (. sd. 5) along the
Aims. Loosening of the tibial component after total knee arthroplasty (TKA) is a common indication for revision. Increasing the strength of the initial tibial implant/cement interface is desirable. There is little information about the surgical techniques that lead to the highest strength. We investigated the effects of eight variables on the strength of the initial tibial baseplate/cement interface. Materials and Methods. A total of 48 tibial trays were cemented into acrylic holders using cement from two manufacturers, at three different times (early, normal, and late) using two techniques: cementing the
Aims. Guided growth using eight-plates is commonly used for correction
of angular limb deformities in growing children. The principle is
of tethering at the physeal periphery while enabling growth in the
rest of the physis. The method is also applied for epiphysiodesis
to correct limb-length discrepancy (LLD). Concerns have been raised
regarding the potential of this method to create an epiphyseal deformity.
However, this has not been investigated. The purpose of this study
was to detect and quantify the occurrence of deformities in the
proximal tibial epiphysis following treatment with eight-plates. Patients and Methods. A retrospective study was performed including 42 children at
a mean age of 10.8 years (3.7 to 15.7) undergoing eight-plate insertion
in the proximal tibia for correction of coronal plane deformities
or LLD between 2007 and 2015. A total of 64 plates were inserted;
48 plates (34 patients) were inserted to correct angular deformities
and 16 plates (8 patients) for LLD. Medical records, Picture Archive
and Communication System images, and conventional radiographs were
reviewed. Measurements included interscrew angle, lateral and medial
plateau slope angles measured between the plateau surface and the
line between the ends of the physis, and
Unstable bicondylar
Mobile-bearing unicompartmental knee replacements
(UKRs) with a flat
We have previously shown that joint distraction and movement with a hinged external fixation device for 12 weeks was useful for repairing a large articular cartilage defect in a rabbit model. We have now investigated the results after six months and one year. The device was applied to 16 rabbits who underwent resection of the articular cartilage and subchondral bone from the entire
We produced large full-thickness articular cartilage defects in 33 rabbits in order to evaluate the effect of joint distraction and autologous culture-expanded bone-marrow-derived mesenchymal cell transplantation (ACBMT) at 12 weeks. After fixing the knee on a hinged external fixator, we resected the entire surface of the
There have been differing descriptions of the
anterolateral structures of the knee, and not all have been named
or described clearly. The aim of this study was to provide a clear
anatomical interpretation of these structures. We dissected 40 fresh-frozen
cadaveric knees to view the relevant anatomy and identified a consistent
structure in 33 knees (83%); we termed this the anterolateral ligament
of the knee. This structure passes antero-distally from an attachment
proximal and posterior to the lateral femoral epicondyle to the
margin of the lateral
We reviewed 34 knees in 24 children after a double-elevating osteotomy for late-presenting infantile Blount’s disease. The mean age of patients was 9.1 years (7 to 13.5). All knees were in Langenskiöld stages IV to VI. The operative technique corrected the depression of the medial joint line by an elevating osteotomy, and the remaining tibial varus and internal torsion by an osteotomy just below the apophysis. In the more recent patients (19 knees), a proximal lateral tibial epiphysiodesis was performed at the same time. The mean pre-operative angle of depression of the medial
Abnormal knee kinematics following reconstruction
of the anterior cruciate ligament may exist despite an apparent resolution
of tibial laxity and functional benefit. We performed upright, weight-bearing
MR scans of both knees in the sagittal plane at different angles
of flexion to determine the kinematics of the knee following unilateral reconstruction
(n = 12). The uninjured knee acted as a control. Scans were performed
pre-operatively and at three and six months post-operatively. Anteroposterior
tibial laxity was determined using an arthrometer and patient function
by validated questionnaires before and after reconstruction. In
all the knees with deficient anterior cruciate ligaments, the tibial
plateau was displaced anteriorly and internally rotated relative
to the femur when compared with the control contralateral knee,
particularly in extension and early flexion (mean lateral compartment displacement:
extension 7.9 mm (. sd 4.8), p = 0.002 and 30° flexion 5.1
mm (. sd. 3.6), p = 0.004). In all ten patients underwent
post-operative scans. Reconstruction reduced the subluxation of
the lateral
This prospective study used magnetic resonance imaging to record sagittal plane tibiofemoral kinematics before and after anterior cruciate ligament reconstruction using autologous hamstring graft. Twenty patients with anterior cruciate ligament injuries, performed a closed-chain leg-press while relaxed and against a 150 N load. The tibiofemoral contact patterns between 0° to 90° of knee flexion were recorded by magnetic resonance scans. All measurements were performed pre-operatively and repeated at 12 weeks and two years. Following reconstruction there was a mean passive anterior laxity of 2.1 mm (. sd. 2.3), as measured using a KT 1000 arthrometer, and the mean Cincinnati score was 90 (. sd. 11) of 100. Pre-operatively, the medial and lateral contact patterns of the injured knees were located posteriorly on the
We studied the kinetics of the knee in 20 patients (22 knees) 12 months after total knee arthroplasty (TKA), by using three-dimensional radiostereometry and film-exchanger techniques. Eleven knees had a concave (constrained) tibial implant and 11 a posterior-stabilised prosthesis. Eleven normal knees served as a control group. In the posterior-stabilised knees there was less proximal and posterior displacement of the centre of the
Conventional high tibial osteotomy for osteoarthritis of the medial compartment of the knee with closed-wedge or dome osteotomy (DMO) may produce shortening of the patellar tendon and loss of inclination of the proximal
The purpose of this study was to assess mid-term survivorship following primary total knee arthroplasty (TKA) with Optetrak Logic components and identify the most common revision indications at a single institution. We identified a retrospective cohort of 7,941 Optetrak primary TKAs performed from January 2010 to December 2018. We reviewed the intraoperative findings of 369 TKAs that required revision TKA from January 2010 to December 2021 and the details of the revision implants used. Kaplan-Meier analysis was used to determine survivorship. Cox regression analysis was used to examine the impact of patient variables and year of implantation on survival time.Aims
Methods
This study aimed to answer the following questions: do 3D-printed models lead to a more accurate recognition of the pattern of complex fractures of the elbow?; do 3D-printed models lead to a more reliable recognition of the pattern of these injuries?; and do junior surgeons benefit more from 3D-printed models than senior surgeons? A total of 15 orthopaedic trauma surgeons (seven juniors, eight seniors) evaluated 20 complex elbow fractures for their overall pattern (i.e. varus posterior medial rotational injury, terrible triad injury, radial head fracture with posterolateral dislocation, anterior (trans-)olecranon fracture-dislocation, posterior (trans-)olecranon fracture-dislocation) and their specific characteristics. First, fractures were assessed based on radiographs and 2D and 3D CT scans; and in a subsequent round, one month later, with additional 3D-printed models. Diagnostic accuracy (acc) and inter-surgeon reliability (κ) were determined for each assessment.Aims
Methods
This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS). Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed.Aims
Methods