Aims. The degree of displacement of a fracture of the distal radius
is an important factor which can be assessed using simple radiographic
measurements. Our aim was to investigate the reliability and reproducibility
of these
Previous standards for assessing the reliability
of a
Aims. The amount of glenoid bone loss is an important factor in deciding between soft-tissue and bony reconstruction when managing anterior shoulder instability. Accurate and reproducible
Aims. The aims of this study were to compare clinically relevant
Aims. Cross-table lateral (CTL) radiographs are commonly used to measure acetabular component anteversion after total hip arthroplasty (THA). The CTL
Aims. We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. Methods. We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density
Aims. A retrospective study was conducted to measure short-term in vivo linear and volumetric wear of polyethylene (PE) inserts in 101 total knee arthroplasty (TKA) patients using model-based radiostereometric analysis (MBRSA). Patients and Methods. Nonweightbearing supine RSA exams were performed postoperatively and at six, 12, and 24 months. Weightbearing standing RSA exams were performed on select patients at 12 and 24 months. Wear was measured both linearly (joint space) and volumetrically (digital model overlap) at each available follow-up. Precision of both methods was assessed by comparing double RSA exams. Patient age, sex, body mass index, and Oxford Knee Scores were analyzed for any association with PE wear. Results. Linear wear occurred at 0.015 mm/year (supine) and 0.220 mm/year (standing). Volumetric wear occurred at 10.3 mm. 3. /year (supine) and 39.3 mm. 3. /year (standing). Wear occurred primarily on the medial side of the joint. Weightbearing imaging greatly improved the reliability of
Aims. The aim of this study was to examine whether hips with unilateral osteoarthritis (OA) secondary to developmental dysplasia of the hip (DDH) have significant asymmetry in femoral length, and to determine potential related factors. Patients and Methods. We enrolled 90 patients (82 female, eight male) with DDH showing unilateral OA changes, and 43 healthy volunteers (26 female, 17 male) as controls. The mean age was 61.8 years (39 to 93) for the DDH groups, and 71.2 years (57 to 84) for the control group. Using a CT-based coordinate
Aims. The aim of this study was to analyse the effect of altered viewing
perspectives on the
Version of the femoral stem is an important factor
influencing the risk of dislocation after total hip replacement (THR)
as well as the position of the acetabular component. However, there
is no radiological method of measuring stem anteversion described
in the literature. We propose a radiological method to measure stem
version and have assessed its reliability and validity. In 36 patients
who underwent THR, a hip radiograph and CT scan were taken to measure
stem anteversion. The radiograph was a modified Budin view. This
is taken as a posteroanterior radiograph in the sitting position
with 90° hip flexion and 90° knee flexion and 30° hip abduction.
The angle between the stem-neck axis and the posterior intercondylar
line was measured by three independent examiners. The intra- and
interobserver reliabilities of each
Aims. Diagnosis of cauda equina syndrome (CES) remains difficult; clinical assessment has low accuracy in reliably predicting MRI compression of the cauda equina (CE). This prospective study tests the usefulness of ultrasound bladder scans as an adjunct for diagnosing CES. Methods. A total of 260 patients with suspected CES were referred to a tertiary spinal unit over a 16-month period. All were assessed by Board-eligible spinal surgeons and had transabdominal ultrasound bladder scans for pre- and post-voiding residual (PVR) volume
Static and dynamic
Reimers’ hip migration percentage is commonly used to document the extent of subluxation of the hip in children with spasticity. In this study, two measurers, with six months paediatric orthopaedic experience, measured the migration percentage on 44 pelvic radiographs of children with cerebral palsy, aged between two and eight years. Unknown to the measurers, each radiograph was duplicated, giving 22 non-identical radiographs (44 hips) which were measured twice at time 0 and twice six weeks later. The intra-measurer, intra-sessional absolute differences between the first and second
Our aim was to determine whether tantalum markers improved the accuracy and/or precision of methods for the
We investigated the reproducibility of the various radiological methods of assessment of hip dysplasia by making 474 assessments of hips and quantifying the inter-observer and intra-observer variation. There was a wide range of variability between the readings made by different observers and by one observer on two occasions. A
Individual components of a total hip replacement are difficult to evaluate and quantify. We have studied the assessment of the acetabular component, and conclude that the
We compared goniometric assessment of passive ankle movement with radiographic
The gait pattern of five amputees was recorded by visual observation and also by a quantitative
Current methods of
Dual-energy X-ray absorptiometry (DEXA) is increasingly used to measure changes in bone mineral density (BMD) around femoral prostheses after total hip arthroplasty. We have studied the factors which affect the accuracy of these
Our aim was to determine the precision of the
The existing methods of assessing limb lengthening during total hip arthroplasty (THA) are prone to error because the
The databases of the Picture Archiving and Communication Systems of two hospitals were searched and all children who had a lateral radiograph of the ankle during their attendance at the emergency department were identified. In 227 radiographs, Bohler’s and Gissane’s angles were measured on two separate occasions and by two separate authors to allow calculation of inter- and intra-observer variation. Intraclass correlation coefficients were used to assess the reliability of the
We obtained simultaneous
The variability in
A computer-based image analysis system has been developed as a research tool in total hip replacement. The system has been programmed to take multiple
We assessed the reproducibility and accuracy of four ratios used to measure patellar height, namely the Blackburne-Peel, Caton-Deschamps, Insall-Salvati and modified Insall-Salvati, before and after total knee arthroplasty. The patellar height was measured, by means of the four ratios, on the pre- and post-operative lateral radiographs of 44 patients (45 knees) who had undergone total knee arthroplasty. Two independent observers measured the films sequentially, in identical conditions, totalling 720
We studied serial CT scans of 45 arthritic shoulders (34 rheumatoid, 11 osteoarthritic) and 19 normal shoulders, making
We made a clinical study of polyethylene wear in 240 hips of 187 patients having primary total hip arthroplasties from 1989 to 1990, using uncemented Osteonics components, with a head size of 26 mm. We excluded cups with anteversion of over 20° and measured linear wear by a new method using a digitiser and special software of our design. Follow-up was from two to five years (mean 4.3). The mean age at operation was 50.3 years, with more men than women (1.4:1). The mean linear wear per year was 0.15 mm; this did not increase with the longevity of the prosthesis (p = 0.54). In 59 hips showing evidence of osteolysis, the mean linear wear rate was significantly higher at 0.23 mm/year (p <
0.001). The mean linear wear rate also correlated significantly with age at the time of operation (p = 0.008), but we found no significant correlations with body-weight, gender, aetiology of the disease, thickness of polyethylene, or cup position. Our new method of
A new method for the
1. The importance of accurate methods of measuring the strength of muscles and the amplitude of joint movements in man, both in clinical fields and as criteria of normal function, is discussed. 2. The advantages and disadvantages of subjective and objective methods are reviewed. 3. The main types of apparatus used for the assessment of muscle strength in both normal and clinical conditions are described. A dynamometer of the strain-gauge type is recommended. 4. Methods of measuring the amplitude of movements in man are also described. The protractor type arthrometer is thought to be the most suitable for routine clinical work, but for research purposes a radiographic method may be preferable. 5. The following factors, which must be considered if the
The angle of inclination of the acetabular component in total hip replacement is a recognised contributing factor in dislocation and early wear. During non-navigated surgery, insertion of the acetabular component has traditionally been performed at an angle of 45° relative to the sagittal plane as judged by the surgeon’s eye, the operative inclination. Typically, the method used to assess inclination is the
The aim of this study was to define the microcirculation of the normal rotator cuff during arthroscopic surgery and investigate whether it is altered in diseased cuff tissue. Blood flow was measured intra-operatively by laser Doppler flowmetry. We investigated six different zones of each rotator cuff during the arthroscopic examination of 56 consecutive patients undergoing investigation for impingement, cuff tears or instability; there were 336
Long radiographs are used to measure lower limb axial alignment, to assess the progression of deformity, and to plan corrective surgery. The purpose of this study was to test the belief that jigs are necessary in order to control limb position for radiography. Above-knee amputated limbs were fixed in different positions of rotation and of knee flexion and radiographed to study the effect on the apparent alignment of the limb. If the limb was rotated no more than 10 degrees from the neutral the effect on apparent axial alignment was minimal and radiographic
We have studied the influence of weight-bearing on the
Anteversion of the femoral neck of 30 unpaired dry bones was measured directly, by ultrasound, and by computerised tomography. The angles measured directly corresponded well with the angles found by CT scan, but there was poor correlation between these and the angles measured by ultrasound. At present ultrasound seems to be unsuitable for the
We describe a new method for the accurate
The transcutaneous oxygen pressure (tcPO2) was measured by a polarographic technique in the legs of 161 volunteers and compared with the levels found in 62 patients with ischaemic skin due to peripheral vascular disease. The results show that the tcPO2 was related to the degree of ischaemia and, in many cases, was a more accurate guide to the viability of the skin than clinical assessment.
In a prospective study of the
Accurate
We report the ten-year results for three designs of stem in 240 total hip replacements, for which subsidence had been measured on plain radiographs at regular intervals. Accurate migration patterns could be determined by the method of Einzel-Bild-Roentgen-Analyse-femoral component analysis (EBRA-FCA) for 158 hips (66%). Of these, 108 stems (68%) remained stable throughout, and five (3%) started to migrate after a median of 54 months. Initial migration of at least 1 mm was seen in 45 stems (29%) during the first two years, but these then became stable. We revised 17 stems for aseptic loosening, and 12 for other reasons. Revision for aseptic loosening could be predicted by EBRA-FCA with a sensitivity of 69%, a specificity of 80%, and an accuracy of 79% by the use of a threshold of subsidence of 1.5 mm during the first two years. Similar observations over a five-year period allowed the long-term outcome to be predicted with an accuracy of 91%. We discuss the importance of four different patterns of subsidence and confirm that the early
Many radiographic techniques have been described for measuring patellar height. They can be divided into two groups: those that relate the position of the patella to the femur (direct) and those that relate it to the tibia (indirect). This article looks at the methods that have been described, the logic behind their conception and the critical analyses that have been performed to test them.
There have been conflicting reports on the effects of gamma irradiation on the material properties of cortical allograft bone. To investigate changes which result from the method of preparation, test samples must be produced with similar mechanical properties to minimise variations other than those resulting from treatment. We describe a new method for the comparative
The
Fractures and plastic deformities of the forearm are common in children. While axial deformities are easily recognised and treated, bowing of the radius may be overlooked. Physiological bowing is essential for full rotation of the forearm. We have used the method of Schemitsch and Richards to estimate the degree of bowing in 100 children who had not suffered a fracture of the forearm. The site of maximum bowing remained constant at 60.39% of the length of the radius (95% CI 59.65 to 61.14). The value of maximum bowing did not exceed 10% of the total length (mean value 7.21%; 95% CI 7.00 to 7.41). This study provides information that can be useful for the diagnosis of bowing and for the evaluation of post-traumatic deformities.
A method is described of measuring the lumbar spinal canal by pulsed echo ultrasound. It is simple, safe and has a high degree of accuracy. The lumbar canal has been measured in over 800 subjects including 100 mining recruits and fifty nurses between the ages of fifteen and eighteen years. Ultrasound can demonstrate the degree and extent of bony stenosis. It may have value in preventive medicine, identifying the subject at risk.