It has been noted that bony union of a pars defect can be achieved in children if they wear a trunk brace. Our aim was to evaluate how the stage of the defect on CT and the presence or absence of high signal change in the adjacent pedicle on T2-weighted MRI were related to bony healing. We treated 23 children conservatively for at least three months. There were 19 boys and four girls with a mean age of 13.5 years (7 to 17). They were asked to refrain from sporting activity and to wear a Damen soft thoracolumbosacral type brace. There were 41 pars defects in 23 patients. These were classified as an early, progressive or terminal stage on CT. The early-stage lesions had a hairline crack in the pars interarticularis, which became a gap in the progressive stage. A terminal-stage defect was equivalent to a pseudarthrosis. On the T2-weighted MR scan the presence or absence of high signal change in the adjacent pedicle was assessed and on this basis the defects were divided into high signal change-positive or -negative. Healing of the defect was assessed by CT. In all, 13 (87%) of the 15 early
The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes. Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.Aims
Methods
The results of the treatment of 31 open femoral fractures (29 patients) with significant bone loss in a single trauma unit were reviewed. A protocol of early soft-tissue and bony debridement was followed by skeletal stabilisation using a locked intramedullary nail or a dynamic condylar plate for diaphyseal and metaphyseal fractures respectively. Soft-tissue closure was obtained within 48 hours then followed, if required, by elective bone grafting with or without exchange nailing. The mean time to union was 51 weeks (20 to 156). The time to union and functional outcome were largely dependent upon the location and extent of the bone loss. It was achieved more rapidly in fractures with wedge defects than in those with segmental bone loss. Fractures with metaphyseal
We report the experimental use of three different biological implants to restore articular surface defects: glutaraldehyde-fixed bovine meniscal xenograft, glutaraldehyde-fixed bovine costal cartilage xenograft, and viable osteochondral allografts. The grafts were implanted in the knees of 19 goats who were allowed free-field activity and were studied for up to one year. The natural articular surfaces of meniscal fibrocartilage provided excellent articular surfaces at all times. Equally good articular surfaces were restored by host tissue growth covering costal cartilage grafts at six months, but by 12 months this surface had degenerated. The majority of the allografts survived and integrated with the host at six months, but many showed signs of failure at 12 months. Only three out of seven ungrafted
We report the operative technique and results of a new method of central grafting for persistent nonunion of the tibial shaft. The operation is performed through a lateral approach, anterior to the fibula. Fresh autogenous bone from the iliac crest is used to form a central bridge between the tibia and fibula above, below and at the level of the nonunion. In 48 tibiae, most with long-standing nonunion and some with infection or bone
Fast bowling in the game of cricket requires repetitive spinal extension, lateral deviation, lumbar flexion and thoracodorsal rotation. Back pain is common, and it has been shown that pars interarticularis defects had occurred in over 50% of a group of teenage fast bowlers. Many of these
We reviewed 34 consecutive patients (18 female-16 male) with
isthmic spondylolysis and grade I to II lumbosacral spondylolisthesis
who underwent in situ posterolateral arthodesis between the L5 transverse
processes and the sacral ala with the use of iliac crest autograft.
Ten patients had an associated scoliosis which required surgical correction
at a later stage only in two patients with idiopathic curves unrelated
to the spondylolisthesis. No patient underwent spinal decompression or instrumentation
placement. Mean surgical time was 1.5 hours (1 to 1.8) and intra-operative
blood loss 200 ml (150 to 340). There was one wound infection treated
with antibiotics but no other complication. Radiological assessment
included standing posteroanterior and lateral, Ferguson and lateral flexion/extension
views, as well as CT scans. Aims
Methods
We developed a new porous scaffold made from a synthetic polymer, poly(DL-lactide-co-glycolide) (PLG), and evaluated its use in the repair of cartilage. Osteochondral defects made on the femoral trochlear of rabbits were treated by transplantation of the PLG scaffold, examined histologically and compared with an untreated control group. Fibrous tissue was initially organised in an arcade array with poor cellularity at the articular surface of the scaffold. The tissue regenerated to cartilage at the articular surface. In the subchondral area, new bone formed and the scaffold was absorbed. The histological scores were significantly higher in the defects treated by the scaffold than in the control group (p <
0.05). Our findings suggest that in an animal model the new porous PLG scaffold is effective for repairing full-thickness osteochondral defects without cultured cells and growth factors.
Critical size defects in ovine tibiae, stabilised with intramedullary interlocking nails, were used to assess whether the addition of carboxymethylcellulose to the standard osteogenic protein-1 (OP-1/BMP-7) implant would affect the implant’s efficacy for bone regeneration. The biomaterial carriers were a ‘putty’ carrier of carboxymethylcellulose and bovine-derived type-I collagen (OPP) or the standard with collagen alone (OPC). These two treatments were also compared to “ungrafted” negative controls. Efficacy of regeneration was determined using radiological, biomechanical and histological evaluations after four months of
Although mechanical stabilisation has been a hallmark of orthopaedic surgical management, orthobiologics are now playing an increasing role. Platelet-rich plasma (PRP) is a volume of plasma fraction of autologous blood having platelet concentrations above baseline. The platelet α granules are rich in growth factors that play an essential role in tissue healing, such as transforming growth factor-β, vascular endothelial growth factor, and platelet-derived growth factor. PRP is used in various surgical fields to enhance bone and soft-tissue healing by placing supraphysiological concentrations of autologous platelets at the site of tissue damage. The easily obtainable PRP and its possible beneficial outcome hold promise for new regenerative treatment approaches. The aim of this literature review was to describe the bioactivities of PRP, to elucidate the different techniques for PRP preparation, to review animal and human studies, to evaluate the evidence regarding the use of PRP in trauma and orthopaedic surgery, to clarify risks, and to provide guidance for future research.
This study reviewed the results of a cementless anatomical femoral component to give immediate post-operative stability, and with a narrow distal section in order not to contact the femoral cortex in the diaphysis, ensuring exclusively metaphyseal loading. A total of 471 patients (601 hips) who had a total hip replacement between March 1995 and February 2002 were included in the study. There were 297 men and 174 women. The mean age at the time of operation was 52.7 years (28 to 63). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients two weeks after operation and at the final follow-up examination. The mean follow-up was 8.8 years (5 to 12). The mean pre-operative Harris hip score was 41 points (16 to 54), which improved to a mean of 96 (68 to 100) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. Deep infection occurred in two hips (0.3%) which required revision. One hip (0.2%) required revision of the acetabular component for recurrent dislocation. Bone mineral densitometry revealed a minimal bone loss in the proximal femur. This cementless anatomical femoral component with metaphyseal loading but without distal fixation produced satisfactory fixation and encourages proximal femoral loading.