Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 89 - 96
1 Mar 2024
Heckmann ND Chung BC Liu KC Chen XT Lovro LR Kistler NM White E Christ AB Longjohn DB Oakes DA Lieberman JR

Aims

Modular dual-mobility (DM) articulations are increasingly used during total hip arthroplasty (THA). However, concerns remain regarding the metal liner modularity. This study aims to correlate metal artifact reduction sequence (MARS)-MRI abnormalities with serum metal ion levels in patients with DM articulations.

Methods

A total of 45 patients (50 hips) with a modular DM articulation were included with mean follow-up of 3.7 years (SD 1.2). Enrolled patients with an asymptomatic, primary THA and DM articulation with over two years’ follow-up underwent MARS-MRI. Each patient had serum cobalt, chromium, and titanium levels drawn. Patient satisfaction, Oxford Hip Score, and Forgotten Joint Score-12 (FJS-12) were collected. Each MARS-MRI was independently reviewed by fellowship-trained musculoskeletal radiologists blinded to serum ion levels.


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1449 - 1456
1 Sep 2021
Kazarian GS Lieberman EG Hansen EJ Nunley RM Barrack RL

Aims

The goal of the current systematic review was to assess the impact of implant placement accuracy on outcomes following total knee arthroplasty (TKA).

Methods

A systematic review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines using the Ovid Medline, Embase, Cochrane Central, and Web of Science databases in order to assess the impact of the patient-reported outcomes measures (PROMs) and implant placement accuracy on outcomes following TKA. Studies assessing the impact of implant alignment, rotation, size, overhang, or condylar offset were included. Study quality was assessed, evidence was graded (one-star: no evidence, two-star: limited evidence, three-star: moderate evidence, four-star: strong evidence), and recommendations were made based on the available evidence.


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 27 - 32
1 Jul 2020
Heckmann N Weitzman DS Jaffri H Berry DJ Springer BD Lieberman JR

Aims

Dual mobility (DM) bearings are an attractive treatment option to obtain hip stability during challenging primary and revision total hip arthroplasty (THA) cases. The purpose of this study was to analyze data submitted to the American Joint Replacement Registry (AJRR) to characterize utilization trends of DM bearings in the USA.

Methods

All primary and revision THA procedures reported to AJRR from 2012 to 2018 were analyzed. Patients of all ages were included and subdivided into DM and traditional bearing surface cohorts. Patient demographics, geographical region, hospital size, and teaching affiliation were assessed. Associations were determined by chi-squared analysis and logistic regression was performed to assess outcome variables.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 740 - 747
1 Jul 2003
Dragoo JL Samimi B Zhu M Hame SL Thomas BJ Lieberman JR Hedrick MH Benhaim P

Multipotential processed lipoaspirate (PLA) cells extracted from five human infrapatellar fat pads and embedded into fibrin glue nodules, were induced into the chondrogenic phenotype using chondrogenic media. The remaining cells were placed in osteogenic media and were transfected with an adenovirus carrying the cDNA for bone morphogenetic protein-2 (BMP-2). We evaluated the tissue-engineered cartilage and bone using in vitro techniques and by placing cells into the hind legs of five severe combined immunodeficient mice.

After six weeks, radiological and histological analysis indicated that the PLA cells induced into the chondrogenic phenotype had the histological appearance of hyaline cartilage. Cells transfected with the BMP-2 gene media produced abundant bone, which was beginning to establish a marrow cavity. Tissue-engineered cartilage and bone from infrapatellar fat pads may prove to be useful for the treatment of osteochondral defects.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 877 - 881
1 Nov 1994
Lieberman I Webb J

We reviewed 41 patients over the age of 65 years (mean 76.5) who had suffered cervical spine injuries, 12 of them with neurological deficit. Eleven patients died during treatment, mostly from respiratory disease. Seven patients were treated by surgical stabilisation, five by halo traction, and the rest by rigid collars or halo-vests. The cervical injury was missed at the first examination in four patients. We conclude that most injuries can be treated by a rigid collar, and that the use of a halo-vest or surgical stabilisation are effective alternatives. Bed rest and traction are poorly tolerated by old people. There should be a high index of suspicion that any elderly patient who presents with a history of a fall or minor trauma may have a cervical spine injury.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 568 - 574
1 Jul 1994
Huk O Bansal M Betts F Rimnac C Lieberman Huo M Salvati E

We report a prospective study of the liner-metal interfaces of modular uncemented acetabular components as sources of debris. We collected the pseudomembrane from the screw-cup junction and the empty screw holes of the metal backing of 19 acetabula after an average implantation of 22 months. Associated osteolytic lesions were separately collected in two cases. The back surfaces of the liners and the screws were examined for damage, and some liners were scanned by electron microscopy. The tissues were studied histologically and by atomic absorption spectrophotometry to measure titanium content. The pseudomembrane from the screw-cup junction contained polyethylene debris in seven specimens and metal debris in ten. The material from empty screw holes was necrotic tissue or dense fibroconnective tissue with a proliferative histiocytic infiltrate and foreign-body giant-cell reaction. It contained polyethylene debris in 14 cases and metal in five. The two acetabular osteolytic lesions also showed a foreign-body giant-cell reaction to particulate debris. The average titanium levels in pseudomembranes from the screw-cup junction and the empty screw holes were 959 micrograms/g (48 to 11,900) and 74 micrograms/g (0.72 to 331) respectively. The tissue from the two lytic lesions showed average titanium levels of 139 and 147 micrograms/g respectively. The back surfaces of the PE liners showed surface deformation, burnishing, and embedded metal debris. All 30 retrieved screws demonstrated fretting at the base of the head and on the proximal shaft. Non-articular modular junctions create new interfaces for the generation of particulate debris, which may cause granulomatous reaction.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 869 - 871
1 Nov 1993
Lieberman Moeckel B Evans B Salvati E Ranawat C

We reviewed 19 revision hip arthroplasties in which the new femoral component had been recemented into the old, intact cement mantle. The mean time from the first operation to revision was 64 months and the average follow-up was 59 months. There were 7 excellent, 11 good, and one fair result. No femoral component had been revised for loosening and all the stems appeared radiographically stable. Complications included intraoperative perforation of the femur on two occasions and one dislocation. The use of the cement-within-cement technique requires that the old cement surface be dry and roughened to increase the surface area and that the cement be injected in the liquid phase to prevent lamination. The indications for this technique include a broken stem with an intact distal cement mantle, the removal of a femoral component for revision of a loose cup to improve exposure and/or increase offset, recurrent dislocation secondary to component malposition, and debonding of the femoral component within an intact cement mantle.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 475 - 478
1 May 1993
Lieberman Huo M Schneider R Salvati E Rodi S

We reviewed the plain radiographs, bone scans and hip aspiration results of 54 patients with painful hip arthroplasties which had been explored surgically, to compare the results of the investigations with the operative findings. For acetabular loosening, the sensitivity and specificity of bone scanning were 87% and 95%, with an accuracy of 90%: for serial plain radiography sensitivity was 95%, specificity 100% and accuracy 97%. For femoral component loosening, bone scan sensitivity was 85%, specificity 100% and accuracy 89%: the sensitivity of plain radiography was 100%, with specificity 92% and accuracy 98%. Technetium bone scanning did not provide additional information with regard to loosening and is not necessary in the routine investigation of a painful hip arthroplasty. Serial pain radiography is the most effective method of detecting loosening, and bone scanning is useful only when radiography is inconclusive with regard to loosening or infection.