Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 343 - 347
1 Mar 2013
Odak S Ivory J

Deficiency of the abductor mechanism is a well-recognised cause of pain and limping after total hip replacement (THR). This can be found incidentally at the time of surgery, or it may arise as a result of damage to the superior gluteal nerve intra-operatively, or after surgery owing to mechanical failure of the abductor muscle repair or its detachment from the greater trochanter. The incidence of abductor failure has been reported as high as 20% in some studies. The management of this condition remains a dilemma for the treating surgeon. We review the current state of knowledge concerning post-THR abductor deficiency, including the aetiology, diagnosis and management, and the outcomes of surgery for this condition.

Cite this article: Bone Joint J 2013;95-B:343–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1195 - 1201
1 Nov 2001
McGrath LR Shardlow DL Ingham E Andrews M Ivory J Stone MH Fisher J

We have examined 26 retrieved, failed titanium-alloy femoral stems. The clinical details, radiological appearances and the histology of the surrounding soft tissues in each patient were also investigated.

The stems were predominantly of the flanged design and had a characteristic pattern of wear. A review of the radiographs showed a series of changes, progressive with time. The first was lateral debonding with subsidence of the stem. This was followed by calcar resorption and fragmentation or fracture of the cement. Finally, osteolysis was seen, starting with a radiolucency at the cement-bone interface and progressing to endosteal cavitation.

Three histological appearances were noted: granulomatous, necrobiotic and necrotic. We suggest that an unknown factor, possibly related to the design of the stem, caused it to move early. After this, micromovement at the cement-stem interface led to the generation of particulate debris and fracture of the cement. A soft-tissue reaction to the debris resulted in osteolysis and failure of fixation of the prostheses.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 355 - 357
1 May 1993
Ivory J Thomas I

The results are reported of an audit of allografts collected in the first 18 months of the Leicester Bone Bank. We retrieved 161 femoral heads at primary arthroplasty of which 103 were implanted into 59 patients. There were deep infections in two recipients and wound infections in five. In two of these cases, culture of the femoral head at implantation was positive but the organisms grown were not those which caused the clinical infection. We retrieved 22 large allografts from six cadavers. Four of these were contaminated at retrieval and required irradiation for sterilisation. There has been one clinical infection in the nine large allografts implanted so far. We recommend that all bone banks undertake prospective audit to ensure that high standards are maintained and wastage minimised.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 934 - 934
1 Nov 1992
Ivory J Choudhry R Stoyle T