Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Applied filters
The Bone & Joint Journal
Dates
Year From

Year To
The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 235 - 239
1 Mar 1994
Nilsson L Frazen H Carlsson A Onnerfalt R

We made a study of 49 total hip arthroplasties at five years, comparing the Charnley hip score, the Nottingham Health Profile (NHP) score and the appearance on serial radiographs. Each of the three investigations was performed by an independent observer with no knowledge of the results of the other two studies. The eight patients with radiographic signs of prosthetic loosening had significant reductions in function and quality of life as measured by the NHP questionnaire, but no differences in the mean Charnley hip scores. None of the eight patients had clinical signs of prosthetic loosening sufficient to recommend revision of their THR. The NHP is a relatively low-cost method of providing long-term follow-up of THR.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 638 - 641
1 Aug 1989
Sanzen L Carlsson A

In 50 patients with non-infected total hip arthroplasties (THA), 233 C-reactive protein (CRP) values were obtained over a three-year period. Six of these 50 patients occasionally had CRP values of over 20 mg/l. The erythrocyte sedimentation rate (ESR) and CRP concentration were measured in 23 patients with deep infections of THA before revision. In 11 patients the infections were caused by coagulase-negative staphylococci. CRP exceeded 20 mg/l in 18 patients and the ESR was more than 30 mm/hr in 14. In only one infected patient were both CRP and ESR below these levels. All of 33 patients with non-septic loosening had CRP less than 20 mg/l and ESR less than 30 mm/hr before revision. C-reactive protein seems to be a valuable supplement to the ESR in the monitoring of infection after THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 550 - 555
1 Aug 1988
Linder L Carlsson A Marsal L Bjursten L Branemark P

In an experimental clinical study, 25 implants of pure titanium were inserted into the proximal tibia of 11 volunteer patients, four with rheumatoid arthritis and seven with osteoarthritis. The implants were removed from five weeks to 24 months later and detailed histological analysis was performed. The implants generally healed with direct bone-metal contact, showing so-called osseointegration. Only one of the 21 implants which had been in place for over five months did not show osseointegration, probably because of inadequate primary contact with bone. The presence of rheumatoid disease did not prevent osseointegration, but accompanying osteoporosis seemed to be a risk factor.


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 4 | Pages 658 - 662
1 Nov 1955
Bauer GCH Carlsson A

After the simultaneous administration of radiocalcium and radiophosphorus to young rats the rate of deposition of calcium and of phosphorus in various skeletal parts was computed. Agreement was found between the two sets of data. No difference was thus found in the metabolism of the calcium and of the phosphorus of the bone salt.