Advertisement for orthosearch.org.uk
Results 1 - 67 of 67
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 709 - 714
1 Jun 2022
Stirling PHC Simpson CJ Ring D Duckworth AD McEachan JE

Aims. The aim of this study was to describe the introduction of a virtual pathway for the management of patients with a suspected fracture of the scaphoid, and to report patient-reported outcome measures (PROMs) and satisfaction following treatment using this service. Methods. All adult patients who presented with a clinically suspected scaphoid fracture that was not visible on radiographs at the time of presentation during a one-year period were eligible for inclusion in the pathway. Demographic details, findings on examination, and routine four-view radiographs at the time of presentation were collected. All radiographs were reviewed virtually by a single consultant hand surgeon, with patient-initiated follow-up on request. PROMs were assessed at a minimum of one year after presentation and included the abbreviated version of the Disabilities of the Arm, Shoulder and Hand Score (QuickDASH), the EuroQol five-dimension five-level health questionnaire (EQ-5D-5L), the Net Promoter Score (NPS), and return to work. Results. A total of 221 patients were referred to the virtual pathway. Their mean age was 41 years (range 16 to 87) and there were 99 male patients (45%). A total of 189 patients (86%) were discharged with advice and 19 (9%) were recalled for clinical review: seven with an undisplaced scaphoid fracture, six with another fracture of the hand or wrist, two with a scapholunate ligament injury, and four in whom no abnormality was detected. A total of 13 patients (6%) initiated follow-up with the hand service: no fracture or ligament injury was identified in this group. PROMs were available for 179 patients (81%) at a mean follow-up of 19 months (range 13 to 33). The median QuickDASH score was 2.3 (interquartile range (IQR) 0 to 15.9), the median EQ-5D-5L was 0.85 (IQR 0.73 to 1.00), the NPS was 76, and 173 patients (97%) were satisfied with their treatment. There were no documented cases of symptomatic nonunion one year following injury. Conclusion. We describe the introduction of a virtual pathway for the management of patients with a suspected scaphoid fracture. We found high levels of patient satisfaction, excellent PROMs, and no detrimental effects in the vast majority of cases. Cite this article: Bone Joint J 2022;104-B(6):709–714


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 953 - 962
1 Aug 2022
Johnson NA Fairhurst C Brealey SD Cook E Stirling E Costa M Divall P Hodgson S Rangan A Dias JJ

Aims. There has been an increasing use of early operative fixation for scaphoid fractures, despite uncertain evidence. We conducted a meta-analysis to evaluate up-to-date evidence from randomized controlled trials (RCTs), comparing the effectiveness of the operative and nonoperative treatment of undisplaced and minimally displaced (≤ 2 mm displacement) scaphoid fractures. Methods. A systematic review of seven databases was performed from the dates of their inception until the end of March 2021 to identify eligible RCTs. Reference lists of the included studies were screened. No language restrictions were applied. The primary outcome was the patient-reported outcome measure of wrist function at 12 months after injury. A meta-analysis was performed for function, pain, range of motion, grip strength, and union. Complications were reported narratively. Results. Seven RCTs were included. There was no significant difference in function between the groups at 12 months (Hedges’ g 0.15 (95% confidence interval -0.02 to 0.32); p = 0.082). The complication rate was higher in the operative group and involved more serious complications. Conclusion. We found no difference in functional outcome at 12 months for fractures of the waist of the scaphoid with ≤ 2 mm displacement treated operatively or nonoperatively. The complication rate was higher with operative treatment. Cite this article: Bone Joint J 2022;104-B(8):953–962


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 387 - 393
1 Apr 2024
Dean BJF Riley N Little C Sheehan W Gidwani S Brewster M Dhiman P Costa ML

Aims. There is a lack of published evidence relating to the rate of nonunion seen in occult scaphoid fractures, diagnosed only after MRI. This study reports the rate of delayed union and nonunion in a cohort of patients with MRI-detected acute scaphoid fractures. Methods. This multicentre cohort study at eight centres in the UK included all patients with an acute scaphoid fracture diagnosed on MRI having presented acutely following wrist trauma with normal radiographs. Data were gathered retrospectively for a minimum of 12 months at each centre. The primary outcome measures were the rate of acute surgery, delayed union, and nonunion. Results. A total of 1,989 patients underwent acute MRI for a suspected scaphoid fracture during the study period, of which 256 patients (12.9%) were diagnosed with a previously occult scaphoid fracture. Of the patients with scaphoid fractures, six underwent early surgical fixation (2.3%) and there was a total of 16 cases of delayed or nonunion (6.3%) in the remaining 250 patients treated with cast immobilization. Of the nine nonunions (3.5%), seven underwent surgery (2.7%), one opted for non-surgical treatment, and one failed to attend follow-up. Of the seven delayed unions (2.7%), one (0.4%) was treated with surgery at two months, one (0.4%) did not attend further follow-up, and the remaining five fractures (1.9%) healed after further cast immobilization. All fractures treated with surgery had united at follow-up. There was one complication of surgery (prominent screw requiring removal). Conclusion. MRI-detected scaphoid fractures are not universally benign, with delayed or nonunion of scaphoid fractures diagnosed only after MRI seen in over 6% despite appropriate initial immobilization, with most of these patients with nonunion requiring surgery to achieve union. This study adds weight to the evidence base supporting the use of early MRI for these patients. Cite this article: Bone Joint J 2024;106-B(4):387–393


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 478 - 484
1 Apr 2020
Daniels AM Wyers CE Janzing HMJ Sassen S Loeffen D Kaarsemaker S van Rietbergen B Hannemann PFW Poeze M van den Bergh JP

Aims. Besides conventional radiographs, the use of MRI, CT, and bone scintigraphy is frequent in the diagnosis of a fracture of the scaphoid. However, which techniques give the best results remain unknown. The investigation of a new imaging technique initially requires an analysis of its precision. The primary aim of this study was to investigate the interobserver agreement of high-resolution peripheral quantitative CT (HR-pQCT) in the diagnosis of a scaphoid fracture. A secondary aim was to investigate the interobserver agreement for the presence of other fractures and for the classification of scaphoid fracture. Methods. Two radiologists and two orthopaedic trauma surgeons evaluated HR-pQCT scans of 31 patients with a clinically-suspected scaphoid fracture. The observers were asked to determine the presence of a scaphoid or other fracture and to classify the scaphoid fracture based on the Herbert classification system. Fleiss kappa statistics were used to calculate the interobserver agreement for the diagnosis of a fracture. Intraclass correlation coefficients (ICCs) were used to assess the agreement for the classification of scaphoid fracture. Results. A total of nine (29%) scaphoid fractures and 12 (39%) other fractures were diagnosed in 20 patients (65%) using HR-pQCT across the four observers. The interobserver agreement was 91% for the identification of a scaphoid fracture (95% confidence interval (CI) 0.76 to 1.00) and 80% for other fractures (95% CI 0.72 to 0.87). The mean ICC for the classification of a scaphoid fracture in the seven patients diagnosed with scaphoid fracture by all four observers was 73% (95% CI 0.42 to 0.94). Conclusion. We conclude that the diagnosis of scaphoid and other fractures is reliable when using HR-pQCT in patients with a clinically-suspected fracture. Cite this article: Bone Joint J 2020;102-B(4):478–484


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1205 - 1209
1 Sep 2008
Beeres FJP Rhemrev SJ den Hollander P Kingma LM Meylaerts SAG le Cessie S Bartlema KA Hamming JF Hogervorst M

We evaluated 100 consecutive patients with a suspected scaphoid fracture but without evidence of a fracture on plain radiographs using MRI within 24 hours of injury, and bone scintigraphy three to five days after injury. The reference standard for a true radiologically-occult scaphoid fracture was either a diagnosis of fracture on both MRI and bone scintigraphy, or, in the case of discrepancy, clinical and/or radiological evidence of a fracture. MRI revealed 16 scaphoid and 24 other fractures. Bone scintigraphy showed 28 scaphoid and 40 other fractures. According to the reference standard there were 20 scaphoid fractures. MRI was falsely negative for scaphoid fracture in four patients and bone scintigraphy falsely positive in eight. MRI had a sensitivity of 80% and a specificity of 100%. Bone scintigraphy had a sensitivity of 100% and a specificity of 90%. This study did not confirm that early, short-sequence MRI was superior to bone scintigraphy for the diagnosis of a suspected scaphoid fracture. Bone scintigraphy remains a highly sensitive and reasonably specific investigation for the diagnosis of an occult scaphoid fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1077 - 1085
1 Aug 2012
Yin Z Zhang J Kan S Wang X

Follow-up radiographs are usually used as the reference standard for the diagnosis of suspected scaphoid fractures. However, these are prone to errors in interpretation. We performed a meta-analysis of 30 clinical studies on the diagnosis of suspected scaphoid fractures, in which agreement data between any of follow-up radiographs, bone scintigraphy, magnetic resonance (MR) imaging, or CT could be obtained, and combined this with latent class analysis to infer the accuracy of these tests on the diagnosis of suspected scaphoid fractures in the absence of an established standard. The estimated sensitivity and specificity were respectively 91.1% and 99.8% for follow-up radiographs, 97.8% and 93.5% for bone scintigraphy, 97.7% and 99.8% for MRI, and 85.2% and 99.5% for CT. The results were generally robust in multiple sensitivity analyses. There was large between-study heterogeneity for the sensitivity of follow-up radiographs and CT, and imprecision about their sensitivity estimates. If we acknowledge the lack of a reference standard for diagnosing suspected scaphoid fractures, MRI is the most accurate test; follow-up radiographs and CT may be less sensitive, and bone scintigraphy less specific


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1403 - 1408
1 Oct 2012
Hannemann PFW Göttgens KWA van Wely BJ Kolkman KA Werre AJ Poeze M Brink PRG

The use of pulsed electromagnetic fields (PEMF) to stimulate bone growth has been recommended as an alternative to the surgical treatment of ununited scaphoid fractures, but has never been examined in acute fractures. We hypothesised that the use of PEMF in acute scaphoid fractures would accelerate the time to union by 30% in a randomised, double-blind, placebo-controlled, multicentre trial. A total of 53 patients in three different medical centres with a unilateral undisplaced acute scaphoid fracture were randomly assigned to receive either treatment with PEMF (n = 24) or a placebo (n = 29). The clinical and radiological outcomes were assessed at four, six, nine, 12, 24 and 52 weeks. A log-rank analysis showed that neither time to clinical and radiological union nor the functional outcome differed significantly between the groups. The clinical assessment of union indicated that at six weeks tenderness in the anatomic snuffbox (p = 0.03) as well as tenderness on longitudinal compression of the scaphoid (p = 0.008) differed significantly in favour of the placebo group. We conclude that stimulation of bone growth by PEMF has no additional value in the conservative treatment of acute scaphoid fractures


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 946 - 952
1 Aug 2022
Wu F Zhang Y Liu B

Aims. This study aims to report the outcomes in the treatment of unstable proximal third scaphoid nonunions with arthroscopic curettage, non-vascularized bone grafting, and percutaneous fixation. Methods. This was a retrospective analysis of 20 patients. All cases were delayed presentations (n = 15) or failed nonoperatively managed scaphoid fractures (n = 5). Surgery was performed at a mean duration of 27 months (7 to 120) following injury with arthroscopic debridement and arthroscopic iliac crest autograft. Fracture fixation was performed percutaneously with Kirschner (K)-wires in 12 wrists, a headless screw in six, and a combination of a headless screw and single K-wire in two. Clinical outcomes were assessed using grip strength, patient-reported outcome measures, and wrist range of motion (ROM) measurements. Results. Intraoperatively, established avascular necrosis of the proximal fragment was identified in ten scaphoids. All fractures united within 16 weeks, confirmed by CT. At a mean follow-up of 31 months (12 to 64), there were significant improvements in the Patient-Rated Wrist Evaluation, Mayo Wrist Score, abbreviated Disabilities of the Arm, Shoulder and Hand score, wrist ROM, grip strength, and the patients’ subjective pain score. No peri- or postoperative complications were encountered. Conclusion. Our data indicate that arthroscopic bone grafting and fixation with cancellous autograft is a viable method in the treatment of proximal third scaphoid nonunions, regardless of the vascularity of the proximal fragment. Cite this article: Bone Joint J 2022;104-B(8):946–952


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1070 - 1076
1 Aug 2014
Hannemann PFW van Wezenbeek MR Kolkman KA Twiss ELL Berghmans CHJ Dirven PAMGM Brink PRG Poeze M

We hypothesised that the use of pulsed electromagnetic field (PEMF) bone growth stimulation in acute scaphoid fractures would significantly shorten the time to union and reduce the number of nonunions in a randomised, double-blind, placebo-controlled multicentre trial. A total of 102 patients (78 male, 24 female; mean age 35 years (18 to 77)) from five different medical centres with a unilateral undisplaced acute scaphoid fracture were randomly allocated to PEMF (n = 51) or placebo (n = 51) and assessed with regard to functional and radiological outcomes (multiplanar reconstructed CT scans) at 6, 9, 12, 24 and 52 weeks. The overall time to clinical and radiological healing did not differ significantly between the active PEMF group and the placebo group. We concluded that the addition of PEMF bone growth stimulation to the conservative treatment of acute scaphoid fractures does not accelerate bone healing. Cite this article: Bone Joint J 2014; 96-B:1070–6


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 631 - 634
1 Aug 1987
Bunker T McNamee P Scott T

The results of a prospective multicentre study of the Herbert differential pitch bone screw used to treat 50 scaphoid fractures and non-unions are presented. All fresh fractures and four of the five fracture-dislocations united, an overall union rate of 92%. Although the technique is demanding, the Herbert screw can achieve excellent results in the management of scaphoid fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 535 - 539
1 Jul 1996
Roolker W Tiel-van Buul MMC Bossuyt PMM Bakker AJ Bos KE Marti RK Broekhuizen AH

We have assessed the value of using a simple apparatus, the Carpal Box, in patients with suspected scaphoid fracture, to produce elongated and magnified radiographs of the carpus. The interobserver agreement between 60 observers of standard scaphoid radiographs and longitudinal and transverse Carpal Box radiographs (X-CB) was compared in 11 patients. Three-phase bone scanning was used as a comparative standard. If at least 75% of the observers agreed and the result was confirmed by three-phase bone scanning, the outcome was termed reliable. Scaphoid radiographs and the longitudinal X-CB films were reliable in four patients and the transverse X-CB films in six patients. The bone scan suggested a scaphoid fracture in five of the 11 patients. Agreement in the interpretation of the standard scaphoid radiographs was acceptable in only 36% of patients: in interpretation of transverse Carpal Box radiographs this figure increased to 55%


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 299 - 301
1 Mar 1988
Dias J Taylor M Thompson J Brenkel I Gregg P

Inter-observer agreement and reproducibility of opinion were assessed for the radiographic diagnosis of union of scaphoid fractures on films taken 12 weeks after injury. Weighted kappa statistics were used to compare the opinions of eight senior observers reviewing 20 sets of good quality radiographs on two occasions separated by two months. There was poor agreement on whether trabeculae crossed the fracture line, whether there was sclerosis at or near the fracture and on whether the proximal part of the scaphoid was avascular. As a consequence, agreement on union also was poor; it appears that radiographs taken 12 weeks after a scaphoid fracture do not provide reliable and reproducible evidence of healing


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 61 - 65
1 Jan 1993
Tiel-van Buul M van Beek E Broekhuizen A Bakker A Bos K van Royen E

Radiographs of the scaphoid after injury are difficult to interpret, and bone scintigraphy is widely used to increase the accuracy of diagnosis, though many fractures suspected on scintigraphy cannot be confirmed radiologically. We have reviewed the clinical consequences, after one year, of managing suspected scaphoid fractures according to the bone-scan results. We studied 160 patients, 35 of whom had initially positive radiographs and were treated in a cast for 12 weeks. The other 125 had bone scintigraphy and were managed according to the result. After a minimum of one year 119 patients were reviewed. Scintigraphically suspected scaphoid fracture could not be confirmed radiologically in 25%. There were no cases of nonunion. The long period of immobilisation in patients with positive radiographs or positive bone scans did not influence the frequency or severity of late symptoms compared with those with a normal bone scan


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 218 - 224
1 Mar 1998
Compson JP

Various classifications of scaphoid fractures have been based on plain radiography, but there are difficulties in defining the actual fracture line without an appreciation of the three-dimensional anatomy. Radiological fracture lines were therefore mapped on transparent methylmethacrylate models of the bone. An analysis of 91 acute fractures showed that 11 were apparently incomplete. The other 80 showed three basic anatomical patterns: transverse through the waist, oblique in the plane of the dorsal sulcus, or of the proximal pole. There was some variation and comminution in these patterns, but no distal fractures of the body were seen. The interpretation of different radiological projections is discussed. The findings have implications for the management and the assessment of outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 98 - 101
1 Jan 1990
Dias J Thompson J Barton N Gregg P

Twenty observers reported independently on the presence or absence of a fracture of the scaphoid on 60 sets of radiographs; these included initial and 2- to 3-week views in patients in whom the outcome was known, normal scaphoids and random copies of these. Analysis of variance of the accuracy of observations revealed that the 2- to 3-week radiographs did not improve diagnostic ability and that this was independent of the experience or seniority of the observer. For normal radiographs, 20% of the observations reported a fracture. Reproducibility of opinion improved with experience but this did not help with accuracy. Radiographs without accurate clinical observation should not determine the management of the suspected scaphoid fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 829 - 831
1 Nov 1988
Kawai H Yamamoto K

Delayed union or non-union of the scaphoid was treated by a bone graft on a pronator quadratus pedicle in eight cases. This produced earlier union than the Russe procedure. The procedure is simple and is recommended for old un-united scaphoid fractures


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 984 - 994
1 Aug 2019
Rua T Malhotra B Vijayanathan S Hunter L Peacock J Shearer J Goh V McCrone P Gidwani S

Aims

The aim of the Scaphoid Magnetic Resonance Imaging in Trauma (SMaRT) trial was to evaluate the clinical and cost implications of using immediate MRI in the acute management of patients with a suspected fracture of the scaphoid with negative radiographs.

Patients and Methods

Patients who presented to the emergency department (ED) with a suspected fracture of the scaphoid and negative radiographs were randomized to a control group, who did not undergo further imaging in the ED, or an intervention group, who had an MRI of the wrist as an additional test during the initial ED attendance. Most participants were male (52% control, 61% intervention), with a mean age of 36.2 years (18 to 73) in the control group and 38.2 years (20 to 71) in the intervention group. The primary outcome was total cost impact at three months post-recruitment. Secondary outcomes included total costs at six months, the assessment of clinical findings, diagnostic accuracy, and the participants’ self-reported level of satisfaction. Differences in cost were estimated using generalized linear models with gamma errors.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 837 - 838
1 Sep 1993
Nathan S


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 626 - 630
1 Jul 2004
Barton NJ


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 85 - 90
1 Jan 1999
Kulkarni RW Wollstein R Tayar R Citron N

We studied 45 patients with 46 fractures of the scaphoid who presented sequentially over a period of 21 months. MRI enabled us to relate the pattern of the fracture to the blood supply of the scaphoid. Serial MRI studies of the four main patterns showed that each followed a constant sequence during healing and failure to progress normally predicted nonunion.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 933 - 933
1 Sep 1998
EHRENDORFER S


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 899 - 905
1 Jul 2008
Dias JJ Dhukaram V Abhinav A Bhowal B Wildin CJ

We report the outcome at a mean of 93 months (73 to 110) of 71 patients with an acute fracture of the scaphoid who were randomised to Herbert screw fixation (35) or below-elbow plaster cast immobilisation (36). These 71 patients represent the majority of a randomised series of 88 patients whose short-term outcome has previously been reported. Those patients available for later review were similar in age, gender and hand dominance.

There was no statistical difference in symptoms and disability as assessed by the mean Patient Evaluation Measure (p = 0.4), or mean Patient-Rated Wrist Evaluation (p = 0.9), the mean range of movement of the wrist (p = 0.4), mean grip strength (p = 0.8), or mean pinch strength (p = 0.4).

Radiographs were available from the final review for 59 patients. Osteoarthritic changes were seen in the scaphotrapezial and radioscaphoid joints in eight (13.5%) and six patients (10.2%), respectively. Three patients had asymptomatic lucency surrounding the screw. One non-operatively treated patient developed nonunion with avascular necrosis. In five patients who were treated non-operatively (16%) there was an abnormal scapholunate angle ( > 60°), but in four of these patients this finding was asymptomatic.

No medium-term difference in function or radiological outcome was identified between the two treatment groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 181 - 181
1 Jan 1998
COONEY WP


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 974 - 975
1 Nov 1993
Stothard J Kumar A


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 828 - 832
1 Sep 1991
Clay N Dias J Costigan P Gregg P Barton N

Immobilisation of the thumb is widely believed to be important in the management of fractures of the carpal scaphoid. To assess the need for this, we randomly allocated 392 fresh fractures for treatment by either a forearm gauntlet (Colles') cast, leaving the thumb free, or by a conventional 'scaphoid' plaster incorporating the thumb as far as its interphalangeal joint. In the 292 fractures which were followed for six months, the incidence of nonunion was independent of the type of cast used.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1277 - 1283
1 Jul 2021
Hinde S Richardson G Fairhurst C Brealey SD Cook L Rangan A Costa ML Dias JJ

Aims. The aim of the Scaphoid Waist Internal Fixation for Fractures Trial (SWIFFT) was to determine the optimal treatment for adults with a bicortical undisplaced or minimally displaced fracture of the waist of the scaphoid, comparing early surgical fixation with initial cast immobilization, with immediate fixation being offered to patients with nonunion. Methods. A cost-effectiveness analysis was conducted to assess the relative merits of these forms of treatment. The differences in costs to the healthcare system and quality-adjusted life years (QALYs) of the patients over the one-year follow-up of the trial in the two treatment arms were estimated using regression analysis. Results. Our base case analysis found that patients randomized to early surgical fixation had statistically significantly higher mean costs to the NHS of £1,295 more than for the cast immobilization arm (p < 0.001), primarily due to the cost of surgery. They also had a marginally better quality of life, over the period, of 0.0158 QALYs; however, this was not statistically significant (p = 0.379). The mean combined cost per additional QALY was £81,962, well above the accepted threshold for cost-effectiveness used in the UK and internationally. The probability of early surgery being cost-effective in this setting was only 5.6%. Conclusion. Consistent with the clinical findings of SWIFFT, these results indicate that initial cast immobilization of minimally displaced scaphoid fractures, with immediate fixation only offered to patients with nonunion, is the optimal form of treatment, resulting in comparable outcomes with less cost to the healthcare system. Cite this article: Bone Joint J 2021;103-B(7):1277–1283


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1200 - 1209
14 Sep 2020
Miyamura S Lans J He JJ Murase T Jupiter JB Chen NC

Aims. We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. Methods. We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves. Results. In the nonunion group, both the distal (100.2%) and proximal (126.6%) fragments had a significantly higher bone density compared to the union (distal: 85.7%; proximal: 108.3%) or control groups (distal: 91.6%; proximal: 109.1%) using the 3D bone density measurement, which were statistically significant for all comparisons. 2D measurements were highly correlated to 3D bone density measurements (Spearman’s correlation coefficient (R) = 0.85 to 0.95). Using 2D measurements, ROC curve analysis revealed the optimal cutoffs of 90.8% and 116.3% for distal and proximal fragments. This led to a sensitivity of 1.00 if either cutoff is met and a specificity of 0.82 when both cutoffs are met. Conclusion. Using 3D modelling software, nonunions were found to exhibit bone density increases in both the distal and proximal fragments in CTs performed between four to 18 weeks after fracture during the course of treatment. 2D bone density measurements using standard CT scans correlate well with 3D models. In patients with scaphoid fractures, CT bone density measurements may be useful in predicting the likelihood of nonunion. Cite this article: Bone Joint J 2020;102-B(9):1200–1209


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 654 - 659
1 May 2016
Garala K Taub NA Dias JJ

Aims. This study explores the epidemiology of patients with a fracture of the scaphoid presenting to a regional teaching hospital. Patients and Methods. All patients with a confirmed fracture of the scaphoid over a retrospective period between January 2010 and May 2013 were included. Their demographics, deprivation status and when the fracture occurred was noted and assessed. There were 415 fractures in 365 males and 50 females. Results. The incidence of fracture of the scaphoid was 12.4 in 100 000 each year in the general population. The mean age of the patients was 22 years (nine to 35); the highest incidence was in males aged between 15 and 19 years. We calculate the annual incidence in the United Kingdom to be 7265 each year. Patients with the lowest socioeconomic status had an incidence of 18.57 in 100 000 whereas the least deprived patients had an incidence of 9.98 (p < 0.001). There was evidence of a seasonal trend (p = 0.022) with the highest monthly rate found in June (16.96 in 100 000 each year) and the lowest was in December (7.61 in 100 000 each year). There were significantly fewer presentations of fracture at the weekend (p <  0.001), and the highest incidence was on Mondays. Most fractures occurred at the waist (64%) and tubercle (18.1%). Take home message: In this large-scale epidemiological study, we confirmed that young men are most at risk of sustaining a fracture of the scaphoid, and report new factors in relation to social deprivation and seasonality that influence scaphoid fractures. Cite this article: Bone Joint J 2016;98-B:654–9


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 847 - 848
1 Jun 2011
Gunal I Altay T

Avascular necrosis of the scaphoid following a fracture in children is rare and there is no established treatment protocol in the literature. We present two boys with nonunion and avascular necrosis of the scaphoid treated by simple immobilisation. Both cases healed with painless wrists and full movements. Our cases confirm that an ununited scaphoid fracture in children may heal with conservative treatment, even when an MRI scan suggests avascular necrosis. Unlike in adults, operative treatment need only be considered in children when conservative treatment fails


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 627 - 632
1 May 2007
Ramamurthy C Cutler L Nuttall D Simison AJM Trail IA Stanley JK

This study identified variables which influence the outcome of surgical management on 126 ununited scaphoid fractures managed by internal fixation and non-vascular bone grafting. The site of fracture was defined by a new method: the ratio of the length of the proximal fragment to the sum of the lengths of both fragments, calculated using specific views in the plain radiographs. Bone healing occurred in 71% (89) of cases. Only the site of nonunion (p = 1 × 10. −6. ) and the delay to surgery (p = 0.001) remained significant on multivariate analysis. The effect of surgical delay on the probability of union increased as the fracture site moved proximally. A prediction model was produced by stepwise logistic regression analysis, enabling the surgeon to predict the success of surgery where the site of the nonunion and delay to surgery is known


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1213 - 1216
1 Sep 2009
Weber DM Fricker R Ramseier LE

This is a retrospective study of six children with ununited scaphoid fractures treated conservatively. Their mean age was 12.8 years (9.7 to 16.3). Five had no early treatment. Radiological signs of nonunion were found at a mean of 4.6 months (3 to 7) after injury. Treatment consisted of cast immobilisation until clinical and radiological union. The mean clinical and radiological follow-up was for 67 months (17 to 90). We assessed the symptoms, the range of movement of the wrist and the grip strength to calculate the Modified Mayo Wrist score. The fracture united in all patients after a mean period of immobilisation of 5.3 months (3 to 7). Five patients were pain free; one had mild pain. All returned to regular activities, and had a range of movement and grip strength within 25% of normal, resulting in an excellent Modified Mayo Wrist score. Prolonged treatment with cast immobilisation resulted in union of the fracture and an excellent Modified Wrist Score in all patients


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 657 - 662
1 Jun 2023
Meaike JJ Meaike JD Collins MS Bishop AT Shin AY

Aims

The benefit of MRI in the preoperative assessment of scaphoid proximal fragment vascularity remains controversial. The purpose of this study is to compare preoperative MRI findings to intraoperative bleeding of the proximal scaphoid.

Methods

A retrospective review of 102 patients who underwent surgery for scaphoid nonunion between January 2000 and December 2020 at a single institution were identified. Inclusion criteria were: isolated scaphoid nonunion; preoperative MRI assessing the proximal fragment vascularity; and operative details of the vascularity of the proximal fragment with the tourniquet deflated. MRI results and intraoperative findings were dichotomized as either ‘yes’ or ‘no’ for the presence of vascularity. A four-fold contingency table was used to analyze the utility of preoperative MRI with 95% confidence intervals. Relative risk was calculated for subgroups to analyze the association between variables and MRI accuracy.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1036 - 1038
1 Oct 2024
Tennent TD Watts AC Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1008 - 1014
1 Sep 2024
Prijs J Rawat J ten Duis K Assink N Harbers JS Doornberg JN Jadav B Jaarsma RL IJpma FFA

Aims

Paediatric triplane fractures and adult trimalleolar ankle fractures both arise from a supination external rotation injury. By relating the experience of adult to paediatric fractures, clarification has been sought on the sequence of injury, ligament involvement, and fracture pattern of triplane fractures. This study explores the similarities between triplane and trimalleolar fractures for each stage of the Lauge-Hansen classification, with the aim of aiding reduction and fixation techniques.

Methods

Imaging data of 83 paediatric patients with triplane fractures and 100 adult patients with trimalleolar fractures were collected, and their fracture morphology was compared using fracture maps. Visual fracture maps were assessed, classified, and compared with each other, to establish the progression of injury according to the Lauge-Hansen classification.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 549 - 558
1 May 2022
Duncumb JW Robinson PG Williamson TR Murray IR Campbell D Molyneux SG Duckworth AD

Aims

The purpose of this systematic review was to determine the rates of union for vascularized versus non-vascularized grafting techniques in the operative management of scaphoid nonunion. Secondary aims were to determine the effect of the fixation techniques used, the source of grafting, as well as the influence of fracture location (proximal pole) and avascular necrosis (AVN).

Methods

A search of PubMed, MEDLINE, and Embase was performed in June 2021 using the Preferred Reporting Items for Systematic Review and Meta-Analyses statement and registered using the PROSPERO International prospective register of systematic reviews. The primary outcome was union rate.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1132 - 1141
1 Oct 2022
Holm-Glad T Røkkum M Röhrl SM Roness S Godang K Reigstad O

Aims

To analyze the short-term outcome of two types of total wrist arthroplasty (TWA) in terms of wrist function, migration, and periprosthetic bone behaviour.

Methods

A total of 40 patients suffering from non-rheumatoid wrist arthritis were enrolled in a randomized controlled trial comparing the ReMotion and Motec TWAs. Patient-rated and functional outcomes, radiological changes, blood metal ion levels, migration measured by model-based radiostereometric analysis (RSA), bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), complications, loosening, and revision rates at two years were compared.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1697 - 1702
1 Dec 2020
Schormans PMJ Kooijman MA Ten Bosch JA Poeze M Hannemann PFW

Aims

Fixation of scaphoid nonunion with a volar locking plate and cancellous bone grafting has been shown to be a successful technique in small series. Few mid- or long-term follow-up studies have been reported. The aim of this study was to report the mid-term radiological and functional outcome of plate fixation for scaphoid nonunion.

Methods

Patients with a scaphoid nonunion were prospectively enrolled and treated with open reduction using a volar approach, debridement of the nonunion, and fixation using a locking plate and cancellous bone grafting, from the ipsilateral iliac crest. Follow-up included examination, functional assessment using the patient-rated wrist/hand evaluation (PRWHE), and multiplanar reformation CT scans at three-month intervals until union was confirmed.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 835 - 838
1 Sep 1990
Sukul D Johannes E Marti R

We report our experience in 42 patients, using corticocancellous bone grafts and lag screw fixation for un-united scaphoid fractures. Using a grading system, we analysed the suitability of the method for three types of nonunion. We recommend the operation for the treatment of scaphoid nonunion, except where there is avascular necrosis of the proximal pole


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 1 | Pages 20 - 23
1 Feb 1977
Southcott R Rosman M

Fracture of the carpal scaphoid is uncommon in children, but does occur and may fail to unite. Eight patients with established non-union have been reiewed, with an average follow-up of almost four years. All non-unions were grafted with autogenous bone. Excellent clinical and radiological results have been obtained. It is concluded that non-union in children is best managed by bone grafting through the anterior approach. Possible aetiological factors concerned in non-union of scaphoid fractures in this age group are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 124 - 127
1 Jan 1987
Ford D Khoury G el-Hadidi S Lunn P Burke F

We have reviewed 22 patients with scaphoid fractures treated by internal fixation with the Herbert screw. Three patients had trans-scaphoid perilunar dislocations, one had an oblique displaced fracture of the waist of the scaphoid and 18 had fractures with delayed or non-union. Corticocancellous bone grafts were added in nine of the cases of non-union. Results were excellent or good in 80% of cases after a mean duration of postoperative immobilisation of four weeks. The technical difficulties are analysed and the problems of applying the jig and of operative exposure are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 293 - 297
1 Mar 1988
Jones W

A consecutive series of 100 cases of wrist injury, other than those referred with a radial fracture, have been reviewed to determine the incidence of acute scapholunate instability; a "clenched fist" radiograph was used in addition to the routine scaphoid views. Of 19 patients with an increase in the scapholunate gap, five were eventually considered to have significant scapholunate instability, two in association with Colles' fractures. Injuries producing significant ligamentous damage and carpal instability may be as common as scaphoid fractures. They require special consideration in diagnosis and management


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 225 - 230
1 May 1981
Leslie I Dickson R

The scaphoid fracture is commonest in young men in the age group 15 to 29 years, who have the highest incidence of non-union, take the longest time to unite, lose more time from work, and spend the longest time as outpatients. A union rate of 95 per cent can be achieved using standard simple treatment. All but a few fractures are visible on the first radiograph, and failure of visualisation at this stage is not associated with a bad outcome. The postero-anterior and semipronated views are the most important to scrutinise. Crank-handle injuries have a particularly bad prognosis when they produce a transverse fracture of the waist of the scaphoid. Poor prognostic factors are displacement during treatment, the fracture line becoming increasingly more obvious, and the presence of early cystic change. The severity of trauma is an important factor to elicit from the history


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 114 - 123
1 Jan 1984
Herbert T Fisher W

A new and simple operative technique has been developed to provide rigid internal fixation for all types of fractures of the scaphoid. This involves the use of a double-threaded bone screw which provides such good fixation that, after operation, a plaster cast is rarely required and most patients are able to return to work within a few weeks. A classification of scaphoid fractures is proposed. The indications for operation included not only acute unstable fractures, but also fractures with delayed healing and those with established non-union; screw fixation was combined with bone grafting to treat non-union. In a prospective trial, 158 operations using this technique were carried out between 1977 and 1981. The rate of union was 100 per cent for acute fractures and 83 per cent overall. This method of treatment appears to offer significant advantages over conventional techniques in the management of the fractured scaphoid


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 1 | Pages 102 - 109
1 Feb 1968
Dooley BJ

Cancellous inlay bone grafting for delayed union or non-union of the scaphoid bone gives good results in most cases (Table IV). The operation is easy, does not require radiological control and does not damage the dorsal arterial plexus. The indications for the operation are twofold: firstly for patients complaining of disabling symptoms in the wrist joint with an established pseudarthrosis of the scaphoid bone, with neither arthritic changes nor severe avascularity of the proximal fragment; and, secondly, for delayed union in recent fractures despite adequate immobilisation. Union may still occur if conservative treatment is continued further, but because this may take up to eighteen months (during which time most patients would be unable to work), operation is a reasonable alternative. In this series two scaphoid fractures united after operation with some collapse of the proximal fragment. This probably resulted from removal of too much bone (preliminary to inlaying the graft) from an already small fragment with a poor blood supply. The operation can be performed even in the presence of a small proximal fragment and gave a satisfactory result in two out of three such cases


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 705 - 713
1 Jul 2004
Bhat M McCarthy M Davis TRC Oni JA Dawson S

We treated 50 patients with fractures of the waist of the scaphoid in a below-elbow plaster cast for up to 13 weeks. Displacement of the fragments was assessed independently by two observers using MRI and radiographs performed within two weeks of injury. The MRI assessments showed that only the measurement of sagittal translation of the fragments and an overall assessment of displacement had satisfactory inter- and intra-observer reproducibility and revealed that nine of the 50 fractures were displaced. Only three of the 49 fractures with adequate follow-up failed to unite, and all were displaced with more than 1 mm of translation in the sagittal plane. If the MRI assessment of displacement of the fracture was used as the measurement of choice, assessment of displacement on the initial scaphoid series of radiographs showed a sensitivity of between 33% and 47% and a positive predictive value of between 27% and 86%. Neither observer was able correctly to identify more than 33% to 47% of the displaced fractures from the plain radiographs. Although the overall assessment of displacement and gapping and translation in the coronal plane on the plain radiographs influenced the rate of union, none of these parameters identified all three fractures which failed to unite. We conclude that the assessment of displacement of scaphoid fractures on MRI can probably be used to assess the likelihood of union although the small number of nonunions limits the power of the study. In contrast, the assessment of displacement on routine radiography is inaccurate and of less value in predicting union


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1321 - 1324
1 Nov 2019
Kerr S Warwick D Haddad FS


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 749 - 754
1 Jun 2020
Jung H Park MJ Won Y Lee GY Kim S Lee JS

Aims

The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear.

Methods

Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1416 - 1423
1 Nov 2018
Rajan PV Qudsi RA Dyer GSM Losina E

Aims

The aim of this study was to assess the quality and scope of the current cost-effectiveness analysis (CEA) literature in the field of hand and upper limb orthopaedic surgery.

Materials and Methods

We conducted a systematic review of MEDLINE and the CEA Registry to identify CEAs that were conducted on or after 1 January 1997, that studied a procedure pertaining to the field of hand and upper extremity surgery, that were clinical studies, and that reported outcomes in terms of quality-adjusted life-years. We identified a total of 33 studies that met our inclusion criteria. The quality of these studies was assessed using the Quality of Health Economic Analysis (QHES) scale.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 443 - 449
1 Apr 2018
Kalsbeek JH van Walsum ADP Vroemen JPAM Janzing HMJ Winkelhorst JT Bertelink BP Roerdink WH

Aims

The objective of this study was to investigate bone healing after internal fixation of displaced femoral neck fractures (FNFs) with the Dynamic Locking Blade Plate (DLBP) in a young patient population treated by various orthopaedic (trauma) surgeons.

Patients and Methods

We present a multicentre prospective case series with a follow-up of one year. All patients aged ≤ 60 years with a displaced FNF treated with the DLBP between 1st August 2010 and December 2014 were included. Patients with pathological fractures, concomitant fractures of the lower limb, symptomatic arthritis, local infection or inflammation, inadequate local tissue coverage, or any mental or neuromuscular disorder were excluded. Primary outcome measure was failure in fracture healing due to nonunion, avascular necrosis, or implant failure requiring revision surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 961 - 968
1 Jul 2012
Duckworth AD Buijze GA Moran M Gray A Court-Brown CM Ring D McQueen MM

A prospective study was performed to develop a clinical prediction rule that incorporated demographic and clinical factors predictive of a fracture of the scaphoid. Of 260 consecutive patients with a clinically suspected or radiologically confirmed scaphoid fracture, 223 returned for evaluation two weeks after injury and formed the basis of our analysis. Patients were evaluated within 72 hours of injury and at approximately two and six weeks after injury using clinical assessment and standard radiographs. Demographic data and the results of seven specific tests in the clinical examination were recorded.

There were 116 (52%) men and their mean age was 33 years (13 to 95; sd 17.9). In 62 patients (28%) a scaphoid fracture was confirmed. A logistic regression model identified male gender (p = 0.002), sports injury (p = 0.004), anatomical snuff box pain on ulnar deviation of the wrist within 72 hours of injury (p < 0.001), and scaphoid tubercle tenderness at two weeks (p < 0.001) as independent predictors of fracture. All patients with no pain at the anatomical snuff box on ulnar deviation of the wrist within 72 hours of injury did not have a fracture (n = 72, 32%). With four independently significant factors positive, the risk of fracture was 91%.

Our study has demonstrated that clinical prediction rules have a considerable influence on the probability of a suspected scaphoid fracture. This will help improve the use of supplementary investigations where the diagnosis remains in doubt.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 503 - 507
1 Apr 2017
White TO Mackenzie SP Carter TH Jefferies JG Prescott OR Duckworth AD Keating JF

Aims

Fracture clinics are often characterised by the referral of large numbers of unselected patients with minor injuries not requiring investigation or intervention, long waiting times and recurrent unnecessary reviews. Our experience had been of an unsustainable system and we implemented a ‘Trauma Triage Clinic’ (TTC) in order to rationalise and regulate access to our fracture service. The British Orthopaedic Association’s guidelines have required a prospective evaluation of this change of practice, and we report our experience and results.

Patients and Methods

We review the management of all 12 069 patients referred to our service in the calendar year 2014, with a minimum of one year follow-up during the calendar year 2015.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 713 - 719
1 Jun 2011
Duckworth AD Ring D McQueen MM

A suspected fracture of the scaphoid remains difficult to manage despite advances in knowledge and imaging methods. Immobilisation and restriction of activities in a young and active patient must be balanced against the risks of nonunion associated with an undiagnosed and undertreated fracture of the scaphoid.

The assessment of diagnostic tests for a suspected fracture of the scaphoid must take into account two important factors. First, the prevalence of true fractures among suspected fractures is low, which greatly reduces the probability that a positive test will correspond with a true fracture, as false positives are nearly as common as true positives. This situation is accounted for by Bayesian statistics. Secondly, there is no agreed reference standard for a true fracture, which necessitates the need for an alternative method of calculating diagnostic performance characteristics, based upon a statistical method which identifies clinical factors tending to associate (latent classes) in patients with a high probability of fracture.

The most successful diagnostic test to date is MRI, but in low-prevalence situations the positive predictive value of MRI is only 88%, and new data have documented the potential for false positive scans. The best strategy for improving the diagnosis of true fractures among suspected fractures of the scaphoid may well be to develop a clinical prediction rule incorporating a set of demographic and clinical factors which together increase the pre-test probability of a fracture of the scaphoid, in addition to developing increasingly sophisticated radiological tests.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 94 - 99
1 Jan 2017
Kim JM Zimmerman RM Jones CM Muhit AA Higgins JP Means Jr KR

Aims

Our purpose was to determine the quality of current randomised controlled trials (RCTs) in hand surgery using standardised metrics.

Materials and Methods

Based on five-year mean impact factors, we selected the six journals that routinely publish studies of upper extremity surgery. Using a journal-specific search query, 62 RCTs met our inclusion criteria. Then three blinded reviewers used the Jadad and revised Coleman Methodology Score (RCMS) to assess the quality of the manuscripts.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1433 - 1439
1 Nov 2011
Dias JJ Singh HP

A displaced fracture of the scaphoid is one in which the fragments have moved from their anatomical position or there is movement between them when stressed by physiological loads. Displacement is seen in about 20% of fractures of the waist of the scaphoid, as shown by translation, a gap, angulation or rotation. A CT scan in the true longitudinal axis of the scaphoid demonstrates the shape of the bone and displacement of the fracture more accurately than do plain radiographs. Displaced fractures can be treated in a plaster cast, accepting the risk of malunion and nonunion. Surgically the displacement can be reduced, checked radiologically, arthroscopically or visually, and stabilised with headless screws or wires. However, rates of union and deformity are unknown. Mild malunion is well tolerated, but the long-term outcome of a displaced fracture that healed in malalignment has not been established.

This paper summarises aspects of the assessment, treatment and outcome of displaced fractures of the waist of the scaphoid.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 224 - 229
1 Feb 2010
Arora R Lutz M Zimmermann R Krappinger D Niederwanger C Gabl M

We report the use of a free vascularised iliac bone graft in the treatment of 21 patients (19 men and 2 women) with an avascular nonunion of the scaphoid in which conventional bone grafting had previously failed. The mean age of the patients was 32 years (23 to 46) and the dominant wrist was affected in 14. The mean interval from fracture to the vascularised bone grafting was 39 months (9 to 62). Pre-operative MRI showed no contrast enhancement in the proximal fragment in any patient. Fracture union was assessed radiologically or with CT scans if the radiological appearances were inconclusive.

At a mean follow-up of 5.6 years (2 to 11) union was obtained in 16 patients. The remaining five patients with a persistent nonunion continued to experience pain, reduced grip strength and limited range of wrist movement. In the successfully treated patients the grip strength and range of movement did not recover to match the uninjured side.

Prevention of progressive carpal collapse, the absence of donor site morbidity, good subjective results and pain relief, justifies this procedure in the treatment of recalcitrant nonunion of the scaphoid.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1429 - 1430
1 Nov 2014
Wilton TJ


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 932 - 936
1 Jul 2011
Mahmoud M Koptan W

Ununited fractures of the scaphoid with extensive bone resorption are usually treated by bone grafting and internal fixation, using either an open or a minimally invasive technique. We studied the feasibility of percutaneous fixation without bone grafting in a consecutive series of 27 patients with established nonunion of an undisplaced fracture of the scaphoid and extensive local resorption of bone. They were treated by a single surgeon with rigid fixation alone, using a headless cannulated screw inserted through a volar percutaneous technique. Clinical examination, standard radiographs and CT confirmed that the fracture had united in all patients at a mean of 11.6 weeks (8 to 16), and that their functional scores had improved.

We concluded that extensive resorption at the fracture site is not an absolute indication for bone grafting, and that percutaneous fixation alone will eventually produce healing of ununited undisplaced fractures of the scaphoid regardless of the size of the gap.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1385 - 1391
1 Oct 2014
Grassmann JP Hakimi M Gehrmann SV Betsch M Kröpil P Wild M Windolf J Jungbluth P

The Essex-Lopresti injury (ELI) of the forearm is a rare and serious condition which is often overlooked, leading to a poor outcome.

The purpose of this retrospective case study was to establish whether early surgery can give good medium-term results.

From a group of 295 patients with a fracture of the radial head, 12 patients were diagnosed with ELI on MRI which confirmed injury to the interosseous membrane (IOM) and ligament (IOL). They were treated by reduction and temporary Kirschner (K)-wire stabilisation of the distal radioulnar joint (DRUJ). In addition, eight patients had a radial head replacement, and two a radial head reconstruction.

All patients were examined clinically and radiologically 59 months (25 to 90) after surgery when the mean Mayo Modified Wrist Score (MMWS) was 88.4 (78 to 94), the mean Mayo Elbow Performance Scores (MEPS) 86.7 (77 to 95) and the mean disabilities of arm, shoulder and hand (DASH) score 20.5 (16 to 31): all of these indicate a good outcome.

In case of a high index of suspicion for ELI in patients with a radial head fracture, we recommend the following: confirmation of IOM and IOL injury with an early MRI scan; early surgery with reduction and temporary K-wire stabilisation of the DRUJ; preservation of the radial head if at all possible or replacement if not, and functional bracing in supination. This will increase the prospect of a good result, and avoid the complications of a missed diagnosis and the difficulties of late treatment.

Cite this article: Bone Joint J 2014;96-B:1385–91.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1413 - 1418
1 Nov 2009
Al-Nammari SS James BK Ramachandran M

The aim of this study was to determine whether the foundation programme for junior doctors, implemented across the United Kingdom in 2005, provides adequate training in musculoskeletal medicine. We recruited 112 doctors on completion of their foundation programme and assessed them using the Freedman and Bernstein musculoskeletal examination tool. Only 8.9% passed the assessment. Those with exposure to orthopaedics, with a career interest in orthopaedics, and who felt that they had gained adequate exposure to musculoskeletal medicine obtained significantly higher scores. Those interested in general practice as a career obtained significantly lower scores. Only 15% had any exposure to orthopaedics during the foundation programme and only 13% felt they had adequate exposure to musculoskeletal medicine. The foundation programme currently provides inadequate training in musculoskeletal medicine. The quality and quantity of exposure to musculoskeletal medicine during the foundation programme must be improved.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 676 - 680
1 May 2006
Givissis P Christodoulou A Chalidis B Pournaras J

A rare case of radiocarpal dislocation is presented. The lunate and proximal pole of the scaphoid were displaced in a volar and proximal direction. The injury was missed initially and the patient was subsequently operated on six weeks later. Open reduction and internal fixation of the scaphoid was performed and this was followed by an uneventful postoperative period, with a satisfactory functional outcome at the eight-year follow-up, despite carpal instability non-dissociative-dorsal intercalated segmental instability configuration of the carpus.

We believe that although open reduction in neglected cases carries the potential risks of avascular necrosis and nonunion of the affected carpal bones, an attempt should be made to restore the anatomy of the carpus.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 809 - 814
1 Jun 2013
Park HY Yoon JO Jeon IH Chung HW Kim JS

This study was performed to determine whether pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient to achieve bony union and restore alignment in scaphoid nonunion. A total of 65 patients who underwent cancellous bone graft and K-wire fixation were included in this study. The series included 61 men and four women with a mean age of 34 years (15 to 72) and mean delay to surgery of 28.7 months (3 to 240). The patients were divided into an unstable group (A) and stable group (B) depending on the pre-operative radiographs. Unstable nonunion was defined as a lateral intrascaphoid angle > 45°, or a radiolunate angle > 10°. There were 34 cases in group A and 31 cases in group B. Bony union was achieved in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B (p = 0.439). Comparison of the post-operative radiographs between the two groups showed no significant differences in lateral intrascaphoid angle (p = 0.657) and scaphoid length (p = 0.670) and height (p = 0.193). The radiolunate angle was significantly different (p = 0.020) but the mean value in both groups was < 10°. Comparison of the dorsiflexion and palmar flexion of movement of the wrist and the mean Mayo wrist score at the final clinical visit in each group showed no significant difference (p = 0.190, p = 0.587 and p = 0.265, respectively). Cancellous bone graft and K-wire fixation were effective in the treatment of stable and unstable scaphoid nonunion.

Cite this article: Bone Joint J 2013;95-B:809–14.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 276 - 280
1 Feb 2012
Buijze GA Weening AA Poolman RW Bhandari M Ring D

Using inaccurate quotations can propagate misleading information, which might affect the management of patients. The aim of this study was to determine the predictors of quotation inaccuracy in the peer-reviewed orthopaedic literature related to the scaphoid. We randomly selected 100 papers from ten orthopaedic journals. All references were retrieved in full text when available or otherwise excluded. Two observers independently rated all quotations from the selected papers by comparing the claims made by the authors with the data and expressed opinions of the reference source. A statistical analysis determined which article-related factors were predictors of quotation inaccuracy. The mean total inaccuracy rate of the 3840 verified quotes was 7.6%. There was no correlation between the rate of inaccuracy and the impact factor of the journal. Multivariable analysis identified the journal and the type of study (clinical, biomechanical, methodological, case report or review) as important predictors of the total quotation inaccuracy rate.

We concluded that inaccurate quotations in the peer-reviewed orthopaedic literature related to the scaphoid were common and slightly more so for certain journals and certain study types. Authors, reviewers and editorial staff play an important role in reducing this inaccuracy.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1597 - 1601
1 Dec 2008
Thompson NW Kapoor A Thomas J Hayton MJ

We describe the use of a vascularised periosteal patch onlay graft based on the 1,2 intercompartmental supraretinacular artery in the management of 11 patients (ten men, one woman) with chronic nonunion involving the proximal third of the scaphoid. The mean age of the patients was 31 years (21 to 45) with the dominant hand affected in eight. Six of the patients were smokers and three had undergone previous surgery to the scaphoid. All of the proximal fragments were avascular. The presence of union was assessed using longitudinal axis CT.

Only three patients progressed to union of the scaphoid and four required a salvage operation for a symptomatic nonunion. The remaining four patients with a persistent nonunion are asymptomatic with low pain scores, good grip strength and a functional range of wrist movement.

Although this technique has potential technical advantages over vascularised pedicled bone grafting, the rate of union has been disappointing and we do not recommend it as a method of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1341 - 1346
1 Oct 2009
Rosenblatt Y Young C MacDermid JC King GJW

Between 1995 and 2006, five intra-articular osteotomies of the head of the radius were performed in patients with symptomatic healed displaced articular fractures. Pre-operatively, all patients complained of persistent painful clicking on movement. Only patients with mild or no degenerative changes of the radial head and capitellum were considered for osteotomy. The operations were performed at a mean of 8.2 months (4 to 13) after injury and the patients were reviewed at a mean of 5.5 years (15 months to 12 years) after the osteotomy.

The average Mayo Elbow Performance Index Score improved significantly from 74 before to 88 after operation, with four patients rated as good or excellent (p < 0.05). The subjective patient satisfaction score was 8.4 on a ten-point scale. All osteotomies healed and there were no complications.

In this small series intra-articular osteotomy of the head of the radius was a safe and effective treatment for symptomatic intra-articular malunion without advanced degenerative changes.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 66 - 71
1 Jan 2008
McQueen MM Gelbke MK Wakefield A Will EM Gaebler C

We randomly allocated 60 consecutive patients with fractures of the waist of the scaphoid to percutaneous fixation with a cannulated Acutrak screw or immobilisation in a cast. The range of movement, the grip and pinch strength, the modified Green/O’Brien functional score, return to work and sports, and radiological evidence of union were evaluated at each follow-up visit. Patients were followed sequentially for one year.

Those undergoing percutaneous screw fixation showed a quicker time to union (9.2 weeks vs 13.9 weeks, p < 0.001) than those treated with a cast. There was a trend towards a higher rate of nonunion in the non-operative group, although this was not statistically significant. Patients treated by operation had a more rapid return of function and to sport and full work compared with those managed conservatively. There was a very low complication rate.

We recommend that all active patients should be offered percutaneous stabilisation for fractures of the waist of the scaphoid.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1512 - 1515
1 Nov 2005
Shahane SA Trail IA Takwale VJ Stilwell JH Stanley JK

We describe a technique of soft-tissue reconstruction which is effective for the treatment of chronic lunotriquetral instability. Part of extensor carpi ulnaris is harvested with its distal attachment preserved. It is passed through two drill holes in the triquetrum and sutured to itself. This stabilises the ulnar side of the wrist.

We have reviewed 46 patients who underwent this procedure for post-traumatic lunotriquetral instability with clinical signs suggestive of ulnar-sided carpal instability. Standard radiographs were normal. All patients had pre-operative arthroscopy of the wrist at which dynamic lunotriquetral instability was demonstrated. A clinical rating system for the wrist by the Mayo clinic was used to measure the outcome. In 19 patients the result was excellent, in ten good, in 11 satisfactory and in six poor. On questioning, 40 (87%) patients said that surgery had substantially improved the condition and that they would recommend the operation. However, six (13%) were unhappy with the outcome and would not undergo the procedure again for a similar problem. There were six complications, five of which related to pisotriquetral problems. The mean follow-up was 39.1 months (6 to 100). We believe that tenodesis of extensor carpi ulnaris is a very satisfactory procedure for isolated, chronic post-traumatic lunotriquetral instability in selected patients. In those with associated pathology, the symptoms were improved, but the results were less predictable.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 196 - 201
1 Feb 2007
Veitch S Blake SM David H

We prospectively reviewed 14 patients with deficiency of the proximal pole of the scaphoid who were treated by rib osteochondral replacement arthroplasty.

Improvement in wrist function occurred in all except one patient with enhanced grip strength, less pain and maintenance of wrist movement. In 13 patients wrist function was rated as good or excellent according to the modified wrist function score of Green and O’Brien. The mean pre-operative score of 54 (35 to 80) rose to 79 (50 to 90) at review at a mean of 64 months (27 to 103). Carpal alignment did not deteriorate in any patient and there were no cases of nonunion or significant complications.

This procedure can restore the mechanical integrity of the proximal pole of the scaphoid satisfactorily and maintain wrist movement while avoiding the potential complications of alternative replacement arthroplasty techniques and problems associated with vascularised grafts and salvage techniques.