Aims. Long-term outcomes following the use of human dermal allografts in the treatment of symptomatic irreparable
Aims. Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact
Rotator cuff tears are common in middle-aged and elderly patients. Despite advances in the surgical repair of
Aims. The number of
While the evolution of the bony skeleton of the shoulder girdle is well described, there is little information regarding the soft tissues, in particular of the
We have studied cellular and vascular changes in different stages of full thickness tears of the
Aims. The aim of this study was to compare the characteristics and outcomes of L-shaped and reverse L-shaped
Aims. The aim of this study was to compare the osseous reactions elicited by all-suture, polyetheretherketone (PEEK), and two different biodegradable anchors used during
The aim of this study was to investigate genetic influences on the development and progression of tears of the
Our aim was to determine the most repeatable three-dimensional measurement of glenoid orientation and to compare it between shoulders with intact and torn rotator cuffs. Our null hypothesis was that glenoid orientation in the scapulae of shoulders with a full-thickness tear of the
Aims. The aim of this study was to assess hypertrophy of the extra-articular
tendon of the long head of biceps (LHB) in patients with a rotator
cuff tear. Patients and Methods. The study involved 638 shoulders in 334 patients (175 men, 159
women, mean age 62.6 years; 25 to 81) with unilateral symptomatic
rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon
in the bicipital groove was measured pre-operatively in both shoulders
using ultrasound. There were 154 asymptomatic
Aims. Rotator cuff tendinopathy has a multifactorial origin. Rejecting
the mechanistic theory has also led to abandoning operative treatment
at initial presentation in the first line. Physiotherapy exercise
programmes are the accepted first line treatment. The aim of this
study was to assess the long-term additional benefits of subacromial decompression
in the treatment of
The aim of this study was to investigate the occurrence of tissue hypoxia and apoptosis at different stages of tendinopathy and tears of the
Aims. This study compared patients who underwent arthroscopic repair of large to massive
Aims. The purpose of this study was to determine whether there were long-term differences in outcomes of reverse shoulder arthroplasty (RSA) undertaken for acute proximal humeral fracture versus
The aim of this study was to define the microcirculation of the normal
Aims. The purpose of this study was to compare the effectiveness of surgical repair to conservative treatment and subacromial decompression for the treatment of chronic/degenerative tears of the
We undertook clinical and ultrasonographic examination of the shoulders of 420 asymptomatic volunteers aged between 50 and 79 years. MRI was performed in selected cases. Full-thickness tears of the
We assessed the clinical results, radiographic
outcomes and complications of patients undergoing total shoulder replacement
(TSR) for osteoarthritis with concurrent repair of a full-thickness
rotator cuff tear. Between 1996 and 2010, 45 of 932 patients (4.8%)
undergoing TSR for osteoarthritis underwent
We have conducted a prospective study to assess the mid-term clinical results following arthroscopic repair of the
Little is known about the incidence of rotator
cuff pathology or its demographic associations in the general population.
We undertook a large epidemiological study of
The establishment of a suitable animal model of repair of the
Aims. In patients with a
CT arthrography and arthroscopy were used to assess tears of the
Aims. Failure of healing is a well-known problem after repair of the
We examined cultured osteoblasts derived from paired samples from the greater tuberosity and acromion from eight patients with large chronic tears of the
This review discusses the pathogenesis and surgical treatment of tears of the
In a prospective, randomised study on the repair of tears of the
Aims. The aim of this study was to analyse human muscle tissue before
and after
We explored the trends over time and the geographical
variation in the use of subacromial decompression and rotator cuff
repair in 152 local health areas (Primary Care Trusts) across England.
The diagnostic and procedure codes of patients undergoing certain
elective shoulder operations between 2000/2001 and 2009/2010 were extracted
from the Hospital Episode Statistics database. They were grouped
as 1) subacromial decompression only, 2) subacromial decompression
with
The aim of this study was to determine the effect
of radial extracorporeal shock-wave therapy (rESWT) on patients with
chronic tendinitis of the
In a prospective randomised trial of calcifying tendinitis of the
Aims. The aim of the study was to develop a quantitative scoring system
to predict whether a large-to-massive
Aims. Few risk factors for
Age-related localised deposition of amyloid in connective tissue has been found in degenerative articular and periarticular tissue. Biopsies of the supraspinatus tendon of 28 patients undergoing repair of the
This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn
The aim of this study was to determine the functional outcome and rate of re-tears following mini-open repair of symptomatic large and massive tears of the
The diagnosis of chronic lesions of the
We have performed a double-blind placebo-controlled trial of moderate doses of extracorporeal shock-wave therapy (ESWT) for non-calcific tendonitis of the
A consecutive series of 372 patients who underwent surgery for disorders of the
This is a retrospective review of 108 patients who underwent decompressive anterior acromioplasty for chronic impingement in the absence of a full thickness
From a retrospective, cohort study of 205 patients diagnosed with full-thickness tears of the
The
We have undertaken an in vivo assessment of the tissue metabolism and cellular activity in torn tendons of the
We examined biopsy specimens obtained during surgery on 115 patients with complete
We report the use of the reverse shoulder prosthesis in the revision of a failed shoulder hemiarthroplasty in 19 shoulders in 18 patients (7 men, 11 women) with severe pain and loss of function. The primary procedure had been undertaken for glenohumeral arthritis associated with severe
Aims. Since long-term outcome of teres major tendon transfer surgery
for irreparable posterosuperior
The results of 63 operative repairs of chronic tears of the
We compared time-dependent changes in the biomechanical properties of single-and double-row repair of a simulated acute tear of the
We compared the outcome of arthroscopic repair of the
Double-contrast shoulder arthrograms were performed in 20 patients at an average of 30 months after operative repair of a torn
Os acromiale is a rare anatomical abnormality and treatment is controversial. Our retrospective study analyses the outcome of excision, acromioplasty and bony fusion of the os acromiale when it is associated with a tear of the
This study examined the role of vitamin D as a factor accounting for fatty degeneration and muscle function in the
In order to compare the outcome from surgical repair and physiotherapy, 103 patients with symptomatic small and medium-sized tears of the
We investigated the function of biceps in 18 patients (19 shoulders) with lesions of the
This study evaluates the position of the long
head of biceps tendon using ultrasound following simple tenotomy,
in patients with arthroscopically repaired
We have studied the reported clinical assessment of the presence and extent of a
A cadaver study was performed to determine the effect of arm position and capsular release on
Previous perfusion studies of the
We studied five cadaver shoulders to determine the strength relationship of the four
We reconstructed defects in the infraspinatus tendon using polytetrafluoroethylene (PTFE) felt grafts in 31 beagle dogs and examined the mechanical responses and histocompatibility. Except for one infected specimen, all the reconstructed infraspinatus tendons healed. We examined eight specimens each immediately after surgery and at six and 12 weeks. The ultimate tensile strength of the reconstructed tendons was 60.84 N, 172.88 N, and 306.51 N immediately after surgery and at six and 12 weeks, respectively. The stiffness of the specimens at the PTFE felt-bone interface was 9.61 kN/m, 64.67 kN/m, and 135.09 kN/m immediately after surgery and at six and 12 weeks, respectively. Six tendons were examined histologically at three, six, 12 and 24 weeks. Histological analysis showed that there was ingrowth of fibrous tissue between the PTFE fibres. Foreign-body reactions were found at the margin of the PTFE-bone interface between 12 and 24 weeks. The mechanical recovery and tissue affinity of PTFE felt to bone and to tendon support its use for reconstruction of the
Major ruptures of the
We compared two treatments for tears of the
Latissimus dorsi tendon transfer (LDTT) is technically
challenging. In order to clarify the local structural anatomy, we undertook
a morphometric study using six complete cadavers (12 shoulders).
Measurements were made from the tendon to the nearby neurovascular
structures with the arm in two positions: flexed and internally
rotated, and adducted in neutral rotation. The tendon was then transferred
and measurements were taken from the edge of the tendon to a reference
point on the humeral head in order to assess the effect of a novel
two-stage release on the excursion of the tendon. With the shoulder flexed and internally rotated, the mean distances
between the superior tendon edge and the radial nerve, brachial
artery, axillary nerve and posterior circumflex artery were 30 mm
(26 to 34), 28 mm (17 to 39), 21 mm (12 to 28) and 15 mm (10 to
21), respectively. The mean distance between the inferior tendon
edge and the radial nerve, brachial artery and profunda brachii
artery was 18 mm (8 to 27), 22 mm (15 to 32) and 14 mm (7 to 21), respectively.
Moving the arm to a neutral position reduced these distances. A
mean of 15 mm (8 to 21) was gained from a standard soft-tissue release,
and 32 mm (20 to 45) from an extensile release. These figures help to define further the structural anatomy of
this region and the potential for transfer of the latissimus dorsi
tendon. Cite this article:
A trial-based comparison of the use of resources, costs and quality
of life outcomes of arthroscopic and open surgical management for
rotator cuff tears in the United Kingdom NHS was performed using
data from the United Kingdom Rotator Cuff Study (UKUFF) randomised
controlled trial. Using data from 273 patients, healthcare-related use of resources,
costs and quality-adjusted life years (QALYs) were estimated at
12 months and 24 months after surgery on an intention-to-treat basis
with adjustment for covariates. Uncertainty about the incremental
cost-effectiveness ratio for arthroscopic Aims
Patients and Methods
We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists. We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity.
Aims. The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up. Methods. Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency,
Surgical repair of posterosuperior rotator cuff
tears has a poorer outcome and a higher rate of failure compared
with repairs of supraspinatus tears. In this prospective cohort
study 28 consecutive patients with an irreparable posterosuperior
rotator cuff tear after failed conservative or surgical treatment
underwent teres major tendon transfer. Their mean age was 60 years
(48 to 71) and the mean follow-up was 25 months (12 to 80). The
mean active abduction improved from 79° (0° to 150°) pre-operatively
to 105° (20° to 180°) post-operatively (p = 0.011). The mean active
external rotation in 90° abduction improved from 25° (0° to 70°)
pre-operatively to 55° (0° to 90°) post-operatively (p <
0.001).
The mean Constant score improved from 43 (18 to 78) pre-operatively
to 65 (30 to 86) post-operatively (p <
0.001). The median post-operative
VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to
5 (0 to 56) post-operatively (p <
0.001). In conclusion, teres major transfer effectively restores function
and relieves pain in patients with irreparable posterosuperior rotator
cuff tears and leads to an overall clinical improvement in a relatively
young and active patient group with limited treatment options. Cite this article:
We describe 14 patients who underwent transfer of latissimus dorsi using a new technique through a single-incision. Their mean age was 61 years (47 to 76) and the mean follow-up was 32 months (19 to 42). The mean Constant score improved from 46.5 to 74.6 points. The mean active flexion increased from 119° to 170°, mean abduction from 118° to 169° and mean external rotation from 19° to 33°. The Hornblower sign remained positive in three patients (23%) as did the external rotation lag sign also in three patients (23%). No patient had a positive drop-arm sign at follow-up. No significant difference was noted between the mean pre- and postoperative acromiohumeral distance as seen on radiographs. An increased grade of osteoarthritis was found in three patients (23%). Electromyographic analysis showed activity of the transferred muscle in all patients.
We have studied the mechanical properties of several current techniques of tendon-to-bone suture employed in rotator-cuff repair. Non-absorbable braided polyester and absorbable polyglactin and polyglycolic acid sutures best combined ultimate tensile strength and stiffness. Polyglyconate and polydioxanone sutures failed only at high loads, but elongated considerably under moderate loads. We then compared the mechanical properties of nine different techniques of tendon grasping, using 159 normal infraspinatus tendons from sheep. The most commonly used simple stitch was mechanically poor: repairs with two or four such stitches failed at 184 N and 208 N respectively. A new modification of the Mason-Allen suture technique improved the ultimate tensile strength to 359 N for two stitches. Finally, we studied the mechanical properties of several methods of anchorage to bone using typically osteoporotic specimens. Single and even double transosseous sutures and suture anchor fixation both failed at low tensile loads (about 140 N). The use of a 2 mm thick, plate-like augmentation device improved the failure strength to 329 N. The mechanical properties of many current repair techniques are poor and can be greatly improved by using good materials, an improved tendon-grasping suture, and augmentation at the bone attachment.
We released the infraspinatus tendons of six sheep, allowed retraction of the musculotendinous unit over a period of 40 weeks and then performed a repair. We studied retraction of the musculotendinous unit 35 weeks later using CT, MRI and macroscopic dissection. The tendon was retracted by a mean of 4.7 cm (3.8 to 5.1) 40 weeks after release and remained at a mean of 4.2 cm (3.3 to 4.7) 35 weeks after the repair. Retraction of the muscle was only a mean of 2.7 cm (2.0 to 3.3) and 1.7 cm (1.1 to 2.2) respectively at these two points. Thus, the musculotendinous junction had shifted distally by a mean of 2.5 cm (2.0 to 2.8) relative to the tendon. Sheep muscle showed an ability to compensate for approximately 60% of the tendon retraction in a hitherto unknown fashion. Such retraction may not be a quantitatively reliable indicator of retraction of the muscle and may overestimate the need for elongation of the musculotendinous unit during repair.
We hypothesised that a large acromial cover with
an upwardly tilted glenoid fossa would be associated with degenerative
rotator cuff tears (RCTs), and conversely, that a short acromion
with an inferiorly inclined glenoid would be associated with glenohumeral
osteoarthritis (OA). This hypothesis was tested using a new radiological parameter,
the critical shoulder angle (CSA), which combines the measurements
of inclination of the glenoid and the lateral extension of the acromion
(the acromion index). The CSA was measured on standardised radiographs of three groups:
1) a control group of 94 asymptomatic shoulders with normal rotator
cuffs and no OA; 2) a group of 102 shoulders with MRI-documented
full-thickness RCTs without OA; and 3) a group of 102 shoulders
with primary OA and no RCTs noted during total shoulder replacement.
The mean CSA was 33.1° (26.8° to 38.6°) in the control group, 38.0°
(29.5° to 43.5°) in the RCT group and 28.1° (18.6° to 35.8°) in
the OA group. Of patients with a CSA >
35°, 84% were in the RCT
group and of those with a CSA <
30°, 93% were in the OA group. We therefore concluded that primary glenohumeral OA is associated
with significantly smaller degenerative RCTs with significantly
larger CSAs than asymptomatic shoulders without these pathologies.
These findings suggest that individual quantitative anatomy may
imply biomechanics that are likely to induce specific types of degenerative
joint disorders. Cite this article:
Differential strain has been proposed to be a causative factor in failure of the supraspinatus tendon. We quantified the strains on the joint and bursal sides of the supraspinatus tendon with increasing load (20 to 200 N) and during 120° of glenohumeral abduction with a constant tensile load (20 to 100 N). We tested ten fresh frozen cadaver shoulders on a purpose-built rig. Differential variable reluctance extensometers allowed calculation of the strain. Static loading to 100 N or more increased strains on the joint side significantly more than on the bursal side. During glenohumeral abduction an increasing and significant difference in strain was measured between the joint and bursal sides of the supraspinatus tendon, which reached a maximum of 10.6% at abduction of 120°. The joint side strain of 7.5% reached values which were previously reported to cause failure. Differential strain causes shearing between the layers of the supraspinatus tendon, which may contribute to the propagation of intratendinous defects that are initiated by high joint side strains.
Using 26 cadaver shoulders, we produced a standard defect in the supraspinatus tendon and performed one of three types of repair. Their strength was found by testing in tension the force required to produce a gap of 3 mm, then 6 mm, and finally total disruption of the repair. The use of a polyethylene patch to spread the forces over the lateral bone surface and of extra sutures to grasp the tendon end raised by 2.6 times the load at which a 3 mm gap in the repair occurred and by 1.7 times the load to failure.
Antegrade nailing of proximal humeral fractures
using a straight nail can damage the bony insertion of the supraspinatus
tendon and may lead to varus failure of the construct. In order
to establish the ideal anatomical landmarks for insertion of the
nail and their clinical relevance we analysed CT scans of bilateral
proximal humeri in 200 patients (mean age 45.1 years ( We therefore emphasise the need for ‘fastidious’ pre-operative
planning to minimise this risk. Cite this article:
Aims. The outcomes following nonoperative management of minimally displaced greater tuberosity (GT) fractures, and the factors which influence patient experience, remain poorly defined. We assessed the early patient-derived outcomes following these injuries and examined the effect of a range of demographic- and injury-related variables on these outcomes. Methods. In total, 101 patients (53 female, 48 male) with a mean age of 50.9 years (19 to 76) with minimally displaced GT fractures were recruited to a prospective observational cohort study. During the first year after injury, patients underwent experiential assessment using the Disabilities of the Arm, Shoulder and Hand (DASH) score and assessment of associated injuries using MRI performed within two weeks of injury. The primary outcome was the one-year DASH score. Multivariate analysis was used to assess the effect of patient demographic factors, complications, and associated injuries, on outcome. Results. The mean DASH score improved from 42.3 (SD 9.6) at six weeks post-injury, to 19.5 (SD 14.3) at one-year follow-up (p < 0.001), but outcomes were mixed, with 30 patients having a DASH score > 30 at one year. MRI revealed a range of associated injuries, with a full-thickness
Aims. The purpose of this study was to identify the changes in untreated long head of the biceps brachii tendon (LHBT) after a
Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a
Aims. Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods. NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact
Aims. The aim of this study is to provide a detailed description of cases combining bridging patch repair with artificial ligament “internal brace” reinforcement to treat irreparable massive
Aims. The aim of this study was to investigate the outcomes of arthroscopic decompression of calcific tendinitis performed without repairing the
Aims. Despite recent advances in arthroscopic rotator cuff repair, re-tear rates remain high. New methods to improve healing rates following
Shoulder injury related to vaccine administration (SIRVA) is a prolonged episode of shoulder dysfunction that commences within 24 to 48 hours of a vaccination. Symptoms include a combination of shoulder pain, stiffness, and weakness. There has been a recent rapid increase in reported cases of SIRVA within the literature, particularly in adults, and is likely related to the mass vaccination programmes associated with COVID-19 and influenza. The pathophysiology is not certain, but placement of the vaccination in the subdeltoid bursa or other pericapsular tissue has been suggested to result in an inflammatory capsular process. It has been hypothesized that this is associated with a vaccine injection site that is “too high” and predisposes to the development of SIRVA. Nerve conduction studies are routinely normal, but further imaging can reveal deep-deltoid collections,
Aims. Advances in arthroscopic techniques for
Aims. The appropriate management for patients with a degenerative tear
of the
Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient
We have compared the outcome of hemiarthroplasty of the shoulder in three distinct diagnostic groups, using survival analysis as used by the United Kingdom national joint registers, patient-reported outcome measures (PROMs) as recommended by Darzi in the 2008 NHS review, and transition and satisfaction questions. A total of 72 hemiarthroplasties, 19 for primary osteoarthritis (OA) with an intact
Aims. The aim of this study was to analyze the results of reverse shoulder
arthroplasty (RSA) in patients with type 1 sequelae of a fracture
of the proximal humerus in association with
There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs. Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the
Aims. Our aim was to describe the atypical pattern of increased fatty
degeneration in the infraspinatus muscle compared with the supraspinatus
in patients with a massive
Aims. The treatment of septic arthritis of the shoulder is challenging.
The infection frequently recurs and the clinical outcome can be
very poor. We aimed to review the outcomes following the use of
continuous negative pressure after open debridement with a large
diameter drain in patients with septic arthritis of the shoulder. Patients and Methods. A total of 68 consecutive patients with septic arthritis of the
shoulder underwent arthrotomy, irrigation and debridement. A small
diameter suction drain was placed in the glenohumeral joint and
a large diameter drain was placed in the subacromial space with
continuous negative pressure of 15 cm H. 2. O. All patients
received a standardised protocol of antibiotics for a mean of 5.1
weeks (two to 11.1). Results. Negative pressure was maintained for a mean of 24 days (14 to
32). A total of 67 patients (98.5%) were cured without further treatment
being required. At a mean follow-up of 14 months (three to 72),
the mean forward flexion was 123° (80° to 140°) and the mean external
rotation was 28°(10° to 40°) in those with a
The purpose of this study was to evaluate the
natural history of rheumatoid disease of the shoulder over an eight-year
period. Our hypothesis was that progression of the disease is associated
with a decrease in function with time. A total of 22 patients (44 shoulders; 17 women, 5 men, (mean
age 63)) with rheumatoid arthritis were followed for eight years.
All shoulders were assessed using the Constant score, anteroposterior
radiographs (Larsen score, Upward-Migration-Index (UMI)) and ultrasound
(US). At final follow-up, the Short Form-36, disabilities of the
arm, shoulder and hand (DASH) Score, erythrocyte sedimentation rate
and use of anti-rheumatic medication were determined. The mean Constant score was 72 points (50 to 88) at baseline
and 69 points (25 to 100) at final follow-up. Radiological evaluation
showed progressive destruction of the peri-articular structures
with time. This progression of joint and
We have used Fourier transform infrared spectroscopy (FTIR) to characterise the chemical and structural composition of the tendons of the
We describe the clinical outcome of a technique of surgical augmentation of chronic massive tears of the
We assessed the predictive value of the macroscopic and detailed microscopic appearance of the coracoacromial ligament, subacromial bursa and rotator-cuff tendon in 20 patients undergoing subacromial decompression for impingement in the absence of full-thickness tears of the