Advertisement for orthosearch.org.uk
Results 1 - 100 of 136
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1133 - 1140
1 Oct 2024
Olsen Kipp J Petersen ET Falstie-Jensen T Frost Teilmann J Zejden A Jellesen Åberg R de Raedt S Thillemann TM Stilling M

Aims. This study aimed to quantify the shoulder kinematics during an apprehension-relocation test in patients with anterior shoulder instability (ASI) and glenoid bone loss using the radiostereometric analysis (RSA) method. Kinematics were compared with the patient’s contralateral healthy shoulder. Methods. A total of 20 patients with ASI and > 10% glenoid bone loss and a healthy contralateral shoulder were included. RSA imaging of the patient’s shoulders was performed during a repeated apprehension-relocation test. Bone volume models were generated from CT scans, marked with anatomical coordinate systems, and aligned with the digitally reconstructed bone projections on the RSA images. The glenohumeral joint (GHJ) kinematics were evaluated in the anteroposterior and superoinferior direction of: the humeral head centre location relative to the glenoid centre; and the humeral head contact point location on the glenoid. Results. During the apprehension test, the centre of the humeral head was 1.0 mm (95% CI 0.0 to 2.0) more inferior on the glenoid for the ASI shoulder compared with the healthy shoulder. Furthermore, the contact point of the ASI shoulder was 1.4 mm (95% CI 0.3 to 2.5) more anterior and 2.0 mm (95% CI 0.8 to 3.1) more inferior on the glenoid compared with the healthy shoulder. The contact point of the ASI shoulder was 1.2 mm (95% CI 0.2 to 2.6) more anterior during the apprehension test compared to the relocation test. Conclusion. The humeral head centre was located more inferior, and the GHJ contact point was located both more anterior and inferior during the apprehension test for the ASI shoulders than the healthy shoulders. Furthermore, the contact point displacement between the apprehension and relocation test revealed increased joint laxity for the ASI shoulder than the healthy shoulders. These results contribute to existing knowledge that ASI shoulders with glenoid bone loss may also suffer from inferior shoulder instability. Cite this article: Bone Joint J 2024;106-B(10):1133–1140


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 520 - 526
1 Apr 2015
Roberts SB Beattie N McNiven ND Robinson CM

The natural history of primary anterior dislocation of the glenohumeral joint in adolescent patients remains unclear and there is no consensus for management of these patients. The objectives of this study were to report the natural history of primary anterior dislocation of the glenohumeral joint in adolescent patients and to identify the risk factors for recurrent dislocation. We reviewed prospectively-collected clinical and radiological data on 133 adolescent patients diagnosed with a primary anterior dislocation of the glenohumeral joint who had been managed non-operatively at our hospital between 1996 and 2008. There were 115 male (86.5%) and 18 female patients (13.5%) with a mean age of 16.3 years (13 to 18) and a mean follow-up of 95.2 months (1 to 215). During follow-up, 102 (absolute incidence of 76.7%) patients had a recurrent dislocation. The median interval between primary and recurrent dislocation was ten months (95% CI 7.4 to 12.6). Applying survival analysis the likelihood of having a stable shoulder one year after the initial injury was 59% (95% CI 51.2 to 66.8), 38% (95% CI 30.2 to 45.8%) after two years, 21% (95% CI 13.2 to 28.8) after five years, and 7% (95% CI 1.1 to 12.9) after ten years. Neither age nor gender significantly predicted recurrent dislocation during follow-up. We conclude that adolescent patients with a primary anterior dislocation of the glenohumeral joint have a high rate of recurrent dislocation, which usually occurs within two years of their initial injury: these patients should be considered for early operative stabilisation. Cite this article: Bone Joint J 2015;97-B:520–6


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 288 - 292
1 Mar 1995
Edelson J

Examination was made of 486 skeletons of subjects over the age of 60 years to study patterns of degenerative change in the glenohumeral joint. Three distinct types were found. Useful clinical implications are drawn from these distinctions


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 935 - 941
1 Jul 2013
Moor BK Bouaicha S Rothenfluh DA Sukthankar A Gerber C

We hypothesised that a large acromial cover with an upwardly tilted glenoid fossa would be associated with degenerative rotator cuff tears (RCTs), and conversely, that a short acromion with an inferiorly inclined glenoid would be associated with glenohumeral osteoarthritis (OA). This hypothesis was tested using a new radiological parameter, the critical shoulder angle (CSA), which combines the measurements of inclination of the glenoid and the lateral extension of the acromion (the acromion index).

The CSA was measured on standardised radiographs of three groups: 1) a control group of 94 asymptomatic shoulders with normal rotator cuffs and no OA; 2) a group of 102 shoulders with MRI-documented full-thickness RCTs without OA; and 3) a group of 102 shoulders with primary OA and no RCTs noted during total shoulder replacement. The mean CSA was 33.1° (26.8° to 38.6°) in the control group, 38.0° (29.5° to 43.5°) in the RCT group and 28.1° (18.6° to 35.8°) in the OA group. Of patients with a CSA > 35°, 84% were in the RCT group and of those with a CSA < 30°, 93% were in the OA group.

We therefore concluded that primary glenohumeral OA is associated with significantly smaller degenerative RCTs with significantly larger CSAs than asymptomatic shoulders without these pathologies. These findings suggest that individual quantitative anatomy may imply biomechanics that are likely to induce specific types of degenerative joint disorders.

Cite this article: Bone Joint J 2013;95-B:935–41.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 406 - 408
1 May 1991
Emery R Mullaji A

One hundred and fifty asymptomatic shoulders in 75 schoolchildren were studied. The shoulders were tested for instability and a hyperextensometer was used to assess joint laxity. Signs of instability were found in 57% of the shoulders in boys and 48% in girls; the commonest sign was a positive posterior drawer test which was found in 63 shoulders. A positive sulcus sign was found in 17 shoulders and 17 subjects had signs of multidirectional instability. General joint laxity was not a feature of subjects whose shoulders had positive instability signs.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 93 - 96
1 Jan 1999
Bokor DJ Conboy VB Olson C

We studied retrospectively a consecutive series of 547 shoulders in 529 patients undergoing operation for instability. In 41, the cause of instability was considered to be lateral avulsion of the capsule, including the inferior glenohumeral ligament, from the neck of the humerus, the HAGL lesion. In 35, the lesion was found at first exploration, whereas in six it was noted at revision of a previous failed procedure. In both groups, the patients were older on average than those with instability from other causes. Of the primary cases, in 33 (94.3%) the cause of the first dislocation was a violent injury; six (17.4%) had evidence of damage to the rotator cuff and/or the subscapularis. Only four (11.4%) had a Bankart lesion. In patients undergoing a primary operation in whom the cause of the first dislocation was a violent injury, who did not have a Bankart lesion and had no suggestion of multidirectional laxity, the incidence of HAGL was 39%.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1314 - 1320
1 Dec 2023
Broida SE Sullivan MH Barlow JD Morrey M Scorianz M Wagner ER Sanchez-Sotelo J Rose PS Houdek MT

Aims. The scapula is a rare site for a primary bone tumour. Only a small number of series have studied patient outcomes after treatment. Previous studies have shown a high rate of recurrence, with functional outcomes determined by the preservation of the glenohumeral joint and deltoid. The purpose of the current study was to report the outcome of patients who had undergone tumour resection that included the scapula. Methods. We reviewed 61 patients (37 male, 24 female; mean age 42 years (SD 19)) who had undergone resection of the scapula. The most common resection was type 2 (n = 34) according to the Tikhoff-Linberg classification, or type S1A (n = 35) on the Enneking classification. Results. The ten-year disease-specific survival was 76%. High tumour grade (hazard ratio (HR) 4.27; p = 0.016) and a total resection of the scapula (HR 3.84; p = 0.015) were associated with worse survival. The ten-year metastasis-free and local recurrence-free survivals were 82% and 86%, respectively. Total scapular resection (HR 6.29; p = 0.004) was associated with metastatic disease and positive margins were associated with local recurrence (HR 12.86; p = 0.001). At final follow-up, the mean shoulder forward elevation and external rotation were 79° (SD 62°) and 27° (SD 25°), respectively. The most recent functional outcomes evaluated included the mean Musculoskeletal Tumor Society Score (76% (SD 17%)), the American Shoulder and Elbow Score (73% (SD 20%)), and the Simple Shoulder Test (7 (SD 3)). Preservation of the glenoid (p = 0.001) and scapular spine (p < 0.001) improved clinical outcomes; interestingly, preservation of the scapular spine without the glenoid improved outcomes (p < 0.001) compared to preservation of the glenoid alone (p = 0.05). Conclusion. Resection of the scapula is a major undertaking with an oncological outcome related to tumour grade, and a functional outcome associated with the status of the scapular spine and glenoid. Positive resection margins are associated with local recurrence. Cite this article: Bone Joint J 2023;105-B(12):1314–1320


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 957 - 963
1 Sep 2024
Baek CH Kim JG Kim BT

Aims. Favourable short-term outcomes have been reported following latissimus dorsi tendon transfer for patients with an irreparable subscapularis (SSC) tendon tear. The aim of this study was to investigate the long-term outcomes of this transfer in these patients. Methods. This was a retrospective study involving 30 patients with an irreparable SSC tear and those with a SSC tear combined with a reparable supraspinatus tear, who underwent a latissimus dorsi tendon transfer. Clinical scores and active range of motion (aROM), SSC-specific physical examination and the rate of return to work were assessed. Radiological assessment included recording the acromiohumeral distance (AHD), the Hamada grade of cuff tear arthropathy and the integrity of the transferred tendon. Statistical analysis compared preoperative, short-term (two years), and final follow-up at a mean of 8.7 years (7 to 10). Results. There were significant improvements in clinical scores, in the range and strength of internal rotation and aROM compared with the preoperative values in the 26 patients (87%) who were available for long-term follow-up. These improvements were maintained between short- and long-term follow-ups. Although there was a decreased mean AHD of 7.3 mm (SD 1.5) and an increased mean Hamada grade of 1.7 (SD 0.5) at final follow-up, the rate of progression of cuff tear arthropathy remained low-grade. Comparison between the isolated SSC and combined SSC and reparable supraspinatus tear groups showed no significant differences. At final follow-up, one patient (3.8%) had undergone revision surgery to a reverse shoulder arthroplasty (RSA). No neurological complications were associated with the procedure. Conclusion. Latissimus dorsi transfer for an irreparable SSC tendon tear resulted in a significant clinical improvement, particularly in pain, range and strength of internal rotation and aROM, which were maintained over a mean of 8.7 years following surgery. Given that this was a long-term outcome study, there was a low-grade progression in the rate of cuff tear arthropathy. Thus, the long-term clinical efficacy of latissimus dorsi tendon transfer in patients with irreparable SSC was confirmed as a joint-preserving procedure for these patients, suggesting it as an effective alternative to RSA in young, active patients without degenerative changes of the glenohumeral joint. Cite this article: Bone Joint J 2024;106-B(9):957–963


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 15 - 21
1 Jan 2019
Kelly MJ Holton AE Cassar-Gheiti AJ Hanna SA Quinlan JF Molony DC

Aims. The glenohumeral joint is the most frequently dislocated articulation, but possibly due to the lower prevalence of posterior shoulder dislocations, approximately 50% to 79% of posterior glenohumeral dislocations are missed at initial presentation. The aim of this study was to systematically evaluate the most recent evidence involving the aetiology of posterior glenohumeral dislocations, as well as the diagnosis and treatment. Materials and Methods. A systematic search was conducted using PubMed (MEDLINE), Web of Science, Embase, and Cochrane (January 1997 to September 2017), with references from articles also evaluated. Studies reporting patients who experienced an acute posterior glenohumeral joint subluxation and/or dislocation, as well as the aetiology of posterior glenohumeral dislocations, were included. Results. A total of 54 studies met the inclusion criteria. In total, 182 patients were included in this analysis; study sizes ranged from one to 66 patients, with a mean age of 44.2 years (. sd. 13.7). There was a higher proportion of male patients. In all, 216 shoulders were included with 148 unilateral injuries and 34 bilateral. Seizures were implicated in 38% of patients (n = 69), with falls, road traffic accidents, electric shock, and iatrogenic reasons also described. Time to diagnosis varied across studies from immediate up to a delay of 25 years. Multiple associated injuries are described. Conclusion. This review provides an up-to-date insight into the aetiology of posterior shoulder dislocations. Our results showed that seizures were most commonly implicated. Overall, reduction was achieved via open means in the majority of shoulders. We also found that delayed diagnosis is common


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 353 - 359
1 Feb 2021
Cho C Min B Bae K Lee K Kim DH

Aims. Ultrasound (US)-guided injections are widely used in patients with conditions of the shoulder in order to improve their accuracy. However, the clinical efficacy of US-guided injections compared with blind injections remains controversial. The aim of this study was to compare the accuracy and efficacy of US-guided compared with blind corticosteroid injections into the glenohumeral joint in patients with primary frozen shoulder (FS). Methods. Intra-articular corticosteroid injections were administered to 90 patients primary FS, who were randomly assigned to either an US-guided (n = 45) or a blind technique (n = 45), by a shoulder specialist. Immediately after injection, fluoroscopic images were obtained to assess the accuracy of the injection. The outcome was assessed using a visual analogue scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the subjective shoulder value (SSV) and range of movement (ROM) for all patients at the time of presentation and at three, six, and 12 weeks after injection. Results. The accuracy of injection in the US and blind groups was 100% (45/45) and 71.1% (32/45), respectively; this difference was significant (p < 0.001). Both groups had significant improvements in VAS pain score, ASES score, SSV, forward flexion, abduction, external rotation, and internal rotation throughout follow-up until 12 weeks after injection (all p < 0.001). There were no significant differences between the VAS pain scores, the ASES score, the SSV and all ROMs between the two groups at the time points assessed (all p > 0.05). No injection-related adverse effects were noted in either group. Conclusion. We found no significant differences in pain and functional outcomes between the two groups, although an US-guided injection was associated with greater accuracy. Considering that it is both costly and time-consuming, an US-guided intra-articular injection of corticosteroid seems not always to be necessary in the treatment of FS as it gives similar outcomes as a blind injection. Cite this article: Bone Joint J 2021;103-B(2):353–359


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 881 - 889
1 Jul 2020
Frank FA Niehaus R Borbas P Eid K

Aims. Conservative treatment of moderately displaced proximal humeral head fractures yields good clinical results, but secondary fragment displacement may occur. Identification of those fractures at risk of displacement may influence initial decision-making. Methods. A total of 163 shoulders in 162 patients with conservatively treated isolated proximal humeral fractures were included. The fractures occurred between January 2015 and May 2018. The mean age of the patients was 69 years (26 to 100) and the mean follow-up was 144 days (42 to 779). The fractures were classified according to Neer. Scores for osteoporosis (Tingart, Deltoid Tuberosity Index (DTI)) and osteoarthritis (OA) of the glenohumeral joint were assessed. Translation of the head on follow-up radiographs of more than 10 mm was defined as displacement. Eccentric head index (EHI) describes the offset of the humeral head centre in relation to the diaphyseal axis. The ratio was estimated on anteroposterior (AP) and Neer views. Medial hinge was considered intact if the medial cortex proximal and distal to the fracture was in line on AP view. Results. Secondary fracture displacement occurred in 41 patients (25.2%). Clinical risk factors were alcohol abuse (odds ratio (OR) 6.8; 95% confidence interval (CI) 1.3 to 36; p = 0.025) and previously diagnosed osteoporosis (OR 4.6; 95% CI 0.6 to 34; p = 0.136). Age (OR 1.1; 95% CI 1.0 to 1.1; p = 0.003) and sex (OR 0.9; 95% CI 0.3 to 2.8; p = 0.867) were not independent factors. Radiological risk factors were OA grade 3 (OR 16.4; 95% CI 0.25 to 37.6; p = 0.107) and osteoporosis with the DTI (OR 10; 95% CI 0.8 to 250; p = 0.031) being more predictive than the Tingart score (OR 2.3; 95% CI 0.8 to 4.7; p = 0.041). A high EHI (AP/Neer > 0.4, OR 18.9; 95% CI 2.1 to 30.9/3.0; 95% CI 1.1 to 8.0; p = 0.002/p = 0.033) and a disrupted medial hinge (OR 3.7; 95% CI 1.1 to 12.6; p = 0.039) increased the risk of secondary displacement significantly. Neer classification had no influence. Conclusion. During conservative treatment, a quarter of patients showed secondary fracture displacement of at least 10 mm. Patients with alcohol abuse, severe OA, and osteoporosis are at risk. Newly defined EHI and disrupted medial hinge are relevant predictors for secondary displacement. Cite this article: Bone Joint J 2020;102-B(7):881–889


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1347 - 1351
1 Oct 2007
Maquieira GJ Espinosa N Gerber C Eid K

The generally-accepted treatment for large, displaced fractures of the glenoid associated with traumatic anterior dislocation of the shoulder is operative repair. In this study, 14 consecutive patients with large (> 5 mm), displaced (> 2 mm) anteroinferior glenoid rim fractures were treated non-operatively if post-reduction radiographs showed a centred glenohumeral joint. After a mean follow-up of 5.6 years (2.8 to 8.4), the mean Constant score and subjective shoulder value were 98% (90% to 100%) and 97% (90% to 100%), respectively. There were no redislocations or subluxations, and the apprehension test was negative. All fragments healed with an average intra-articular step of 3.0 mm (0.5 to 11). No patient had symptoms of osteoarthritis, which was mild in two shoulders and moderate in one. Traumatic anterior dislocation of the shoulder, associated with a large displaced glenoid rim fracture can be successfully treated non-operatively, providing the glenohumeral joint is concentrically reduced on the anteroposterior radiograph


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 231 - 235
1 Feb 2005
Kirkos JM Kyrkos MJ Kapetanos GA Haritidis JH

We describe the long-term results in ten patients with obstetric brachial plexus palsy of anterior shoulder release combined with transfer of teres major and latissimus dorsi posteriorly and laterally to allow them to act as external rotators. Eight patients had a lesion of the superior trunk and two some involvement of the entire brachial plexus. The mean age at operation was six years, and the mean follow-up was 30 years. Before operation, the patients were unable actively to rotate the arm externally beyond neutral, although this movement was passively normal. All showed decreased strength of the external rotator, but had normal strength of the internal rotator muscles. Radiologically, no severe bony changes were seen in the glenohumeral joint. No clinically detectable improvement of active abduction was noted in any patient. The mean active external rotation after operation was 36.5°. This was maintained for a mean of ten years, and then deteriorated in eight patients. At the latest follow-up the mean active external rotation was 10.5°. The early satisfactory results of the procedure were not maintained. In the long term there was loss of active external rotation, possibly because of gradual degeneration of the transferred muscles, contracture of the surrounding soft tissues and degenerative changes in the glenohumeral joint


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1260 - 1264
1 Sep 2012
Raiss P Lin A Mizuno N Melis B Walch G

A total of 12 epileptic patients (14 shoulders) with recurrent seizures and anterior dislocations of the shoulder underwent a Latarjet procedure and were reviewed at a mean of 8.3 years (1 to 20) post-operatively. Mean forward flexion decreased from 165° (100° to 180°) to 160° (90° to 180°) (p = 0.5) and mean external rotation from 54° (10° to 90°) to 43° (5° to 75°) (p = 0.058). The mean Rowe score was 76 (35 to 100) at the final follow-up. Radiologically, all shoulders showed a glenoid-rim defect and Hill-Sachs lesions pre-operatively. Osteo-arthritic changes of the glenohumeral joint were observed in five shoulders (36%) pre-operatively and in eight shoulders (57%) post-operatively. Re-dislocation during a seizure occurred in six shoulders (43%). Five of these patients underwent revision surgery using a bone buttress from the iliac crest and two of these patients re-dislocated due to a new seizure. . Due to the unacceptably high rate of re-dislocation after surgery in these patients, the most important means of reducing the incidence of further dislocation is the medical management of the seizures. The Latarjet procedure should be reserved for the well-controlled patient with epilepsy who has recurrent anterior dislocation of the shoulder during activities of daily living


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1329 - 1335
1 Oct 2007
Lunn JV Castellanos-Rosas J Walch G

We retrospectively identified 18 consecutive patients with synovial chrondromatosis of the shoulder who had arthroscopic treatment between 1989 and 2004. Of these, 15 were available for review at a mean follow-up of 5.3 years (2.3 to 16.5). There were seven patients with primary synovial chondromatosis, but for the remainder, the condition was a result of secondary causes. The mean Constant score showed that pain and activities of daily living were the most affected categories, being only 57% and 65% of the values of the normal side. Surgery resulted in a significant improvement in the mean Constant score in these domains from 8.9 (4 to 15) to 11.3 (2 to 15) and from 12.9 (5 to 20) to 18.7 (11 to 20), respectively (unpaired t-test, p = 0.04 and p < 0.0001, respectively). Movement and strength were not significantly affected. Osteoarthritis was present in eight patients at presentation and in 11 at the final review. Recurrence of the disease with new loose bodies occurred in two patients from the primary group at an interval of three and 12 years post-operatively. In nine patients, loose bodies were also present in the bicipital groove; seven of these underwent an open bicipital debridement and tenodesis. We found that arthroscopic debridement of the glenohumeral joint and open debridement and tenodesis of the long head of biceps, when indicated, are safe and effective in relieving symptoms at medium-term review


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 660 - 665
1 May 2016
Jung HJ Song JH Kekatpure AL Adikrishna A Hong HP Lee WJ Chun JM Jeon IH

Aims. The treatment of septic arthritis of the shoulder is challenging. The infection frequently recurs and the clinical outcome can be very poor. We aimed to review the outcomes following the use of continuous negative pressure after open debridement with a large diameter drain in patients with septic arthritis of the shoulder. Patients and Methods. A total of 68 consecutive patients with septic arthritis of the shoulder underwent arthrotomy, irrigation and debridement. A small diameter suction drain was placed in the glenohumeral joint and a large diameter drain was placed in the subacromial space with continuous negative pressure of 15 cm H. 2. O. All patients received a standardised protocol of antibiotics for a mean of 5.1 weeks (two to 11.1). Results. Negative pressure was maintained for a mean of 24 days (14 to 32). A total of 67 patients (98.5%) were cured without further treatment being required. At a mean follow-up of 14 months (three to 72), the mean forward flexion was 123° (80° to 140°) and the mean external rotation was 28°(10° to 40°) in those with a rotator cuff tear, and 125° (85° to 145°) and 35° (15° to 45°) in those without a rotator cuff tear. Conclusion. Continuous negative pressure, following open arthrotomy, irrigation and debridement, was effective in treating septic arthritis of the shoulder. The rate of recurrence was significantly lower than with conventional treatment involving arthroscopic or open debridement reported in the literature. Functional outcomes, even in patients with rotator cuff tears, were excellent. Take home message: Continuous negative pressure is effective in treating septic arthritis of the shoulder. Cite this article: Bone Joint J 2016;98-B:660–5


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 916 - 919
1 Nov 1991
Laurence M

The rotator cuff is often severely damaged in arthritis of the shoulder and there is no satisfactory technique for its repair. patients with a ruptured cuff and an eroded glenohumeral joint may have intractable pain, and standard methods of joint replacement are then inappropriate. A ball and socket prosthesis has been designed to replace the function of both the rotator cuff and the glenohumeral joint. Mechanical testing has shown that the scapular cup can be securely fixed. The outcome in 71 shoulders operated upon since 1973 is reported


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1256 - 1259
1 Sep 2008
Kedgley AE DeLude JA Drosdowech DS Johnson JA Bicknell RT

This study compared the effect of a computer-assisted and a traditional surgical technique on the kinematics of the glenohumeral joint during passive abduction after hemiarthroplasty of the shoulder for the treatment of fractures. We used seven pairs of fresh-frozen cadaver shoulders to create simulated four-part fractures of the proximal humerus, which were then reconstructed with hemiarthroplasty and reattachment of the tuberosities. The specimens were randomised, so that one from each pair was repaired using the computer-assisted technique, whereas a traditional hemiarthroplasty without navigation was performed in the contralateral shoulder. Kinematic data were obtained using an electromagnetic tracking device. The traditional technique resulted in posterior and inferior translation of the humeral head. No statistical differences were observed before or after computer-assisted surgery. Although it requires further improvement, the computer-assisted approach appears to allow glenohumeral kinematics to more closely replicate those of the native joint, potentially improving the function of the shoulder and extending the longevity of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 619 - 626
1 May 2009
Herrera DA Anavian J Tarkin IS Armitage BA Schroder LK Cole PA

Between 1998 and 2007, 22 patients with fractures of the scapula had operative treatment more than three weeks after injury. The indications for operation included displaced intra-articular fractures, medialisation of the glenohumeral joint, angular deformity, or displaced double lesions of the superior shoulder suspensory complex. Radiological and functional outcomes were obtained for 16 of 22 patients. Disabilities of the Arm, Shoulder, Hand (DASH) and Short form-36 scores were collected for 14 patients who were operated on after March 2002. The mean delay from injury to surgery was 30 days (21 to 57). The mean follow-up was for 27 months (12 to 72). At the last review the mean DASH score was 14 (0 to 41). Of the 16 patients with follow-up, 13 returned to their previous employment and recreational activities without restrictions. No wound complications, infection or nonunion occurred. Malunion of the scapula can be prevented by surgical treatment of fractures in patients with delayed presentation. Surgery is safe, effective, and gives acceptable functional results


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 38 - 42
1 Jan 1998
Gibbons CLMH Bell RS Wunder JS Griffin AM O’Sullivan B Catton CN Davis AM

We describe the functional results in 14 patients (7 men, 7 women) after subtotal scapulectomy for primary bone and soft-tissue tumours at a specialist musculoskeletal oncology unit. Eight had chondrosarcomas, two Ewing’s sarcomas, one aggressive fibromatosis and three soft-tissue sarcomas. The mean follow-up was 52 months (6 to 120). Analysis of residual symptoms and of range and strength of movement by physicians used the Musculoskeletal Tumour Society rating scale (MSTS). Physical disability was measured by the patients using the Toronto Extremity Salvage Score (TESS). All 14 patients are still alive, two with systemic disease. Nine had more than 80% of their scapula resected but the glenohumeral joint was preserved in all cases. Eight had full movement and another two achieved 90° of flexion. The mean functional results were good to excellent in all except three patients (mean MSTS = 71.6 and TESS = 79.9). Two of these three patients had considerable pain as a result of brachial neuropathy. Scapulectomy gives an excellent functional result if the glenohumeral joint is preserved. The rotator cuff could be removed without a severe functional deficit provided that the deltoid was reattached to the scapular remnant and the trapezius


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1100 - 1110
1 Oct 2024
Arenas-Miquelez A Barco R Cabo Cabo FJ Hachem A

Bone defects are frequently observed in anterior shoulder instability. Over the last decade, knowledge of the association of bone loss with increased failure rates of soft-tissue repair has shifted the surgical management of chronic shoulder instability. On the glenoid side, there is no controversy about the critical glenoid bone loss being 20%. However, poor outcomes have been described even with a subcritical glenoid bone defect as low as 13.5%. On the humeral side, the Hill-Sachs lesion should be evaluated concomitantly with the glenoid defect as the two sides of the same bipolar lesion which interact in the instability process, as described by the glenoid track concept. We advocate adding remplissage to every Bankart repair in patients with a Hill-Sachs lesion, regardless of the glenoid bone loss. When critical or subcritical glenoid bone loss occurs in active patients (> 15%) or bipolar off-track lesions, we should consider anterior glenoid bone reconstructions. The techniques have evolved significantly over the last two decades, moving from open procedures to arthroscopic, and from screw fixation to metal-free fixation. The new arthroscopic techniques of glenoid bone reconstruction procedures allow precise positioning of the graft, identification, and treatment of concomitant injuries with low morbidity and faster recovery. Given the problems associated with bone resorption and metal hardware protrusion, the new metal-free techniques for Latarjet or free bone block procedures seem a good solution to avoid these complications, although no long-term data are yet available.

Cite this article: Bone Joint J 2024;106-B(10):1100–1110.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 942 - 946
1 Jul 2013
Dattani R Ramasamy V Parker R Patel VR

There is little published information on the health impact of frozen shoulder. The purpose of this study was to assess the functional and health-related quality of life outcomes following arthroscopic capsular release (ACR) for contracture of the shoulder. Between January 2010 and January 2012 all patients who had failed non-operative treatment including anti-inflammatory medication, physiotherapy and glenohumeral joint injections for contracture of the shoulder and who subsequently underwent an ACR were enrolled in the study. A total of 100 patients were eligible; 68 underwent ACR alone and 32 had ACR with a subacromial decompression (ASD). ACR resulted in a highly significant improvement in the range of movement and functional outcome, as measured by the Oxford shoulder score and EuroQol EQ-5D index. The mean cost of a quality-adjusted life year (QALY) for an ACR and ACR with an ASD was £2563 and £3189, respectively. . ACR is thus a cost-effective procedure that can restore relatively normal function and health-related quality of life in most patients with a contracture of the shoulder within six months after surgery; and the beneficial effects are not related to the duration of the presenting symptoms. Cite this article: Bone Joint J 2013;95-B:942–6


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 455 - 464
15 Mar 2023
de Joode SGCJ Meijer R Samijo S Heymans MJLF Chen N van Rhijn LW Schotanus MGM

Aims

Multiple secondary surgical procedures of the shoulder, such as soft-tissue releases, tendon transfers, and osteotomies, are described in brachial plexus birth palsy (BPBP) patients. The long-term functional outcomes of these procedures described in the literature are inconclusive. We aimed to analyze the literature looking for a consensus on treatment options.

Methods

A systematic literature search in healthcare databases (PubMed, Embase, the Cochrane library, CINAHL, and Web of Science) was performed from January 2000 to July 2020, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. The quality of the included studies was assessed with the Cochrane ROBINS-I risk of bias tool. Relevant trials studying BPBP with at least five years of follow-up and describing functional outcome were included.


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 603 - 609
1 May 2018
Schnetzke M Rick S Raiss P Walch G Loew M

Aims. The aim of this study was to evaluate the clinical and radiological outcome of using an anatomical short-stem shoulder prosthesis to treat primary osteoarthritis of the glenohumeral joint. Patients and Methods. A total of 66 patients (67 shoulders) with a mean age of 76 years (63 to 92) were available for clinical and radiological follow-up at two different timepoints (T1, mean 2.6 years, . sd. 0.5; T2, mean 5.3 years,. sd. 0.7). Postoperative radiographs were analyzed for stem angle, cortical contact, and filling ratio of the stem. Follow-up radiographs were analyzed for timing and location of bone adaptation (cortical bone narrowing, osteopenia, spot welds, and condensation lines). The bone adaptation was classified as low (between zero and three features of bone remodelling around the humeral stem) or high (four or more features). Results. The mean Constant score improved significantly from 28.5 (. sd. 11.6) preoperatively to 75.5 (. sd. 8.5) at T1 (p < 0.001) and remained stable over time (T2: 76.6, . sd. 10.2). No stem loosening was seen. High bone adaptation was present in 42% of shoulders at T1, with a slight decrease to 37% at T2. Cortical bone narrowing and osteopenia in the region of the calcar decreased from 76% to 66% between T1 and T2. Patients with high bone adaptation had a significantly higher mean filling ratio of the stem at the metaphysis (0.60, . sd. 0.05 vs 0.55, . sd. 0.06; p = 0.003) and at the diaphysis (0.65 . sd. 0.05 vs 0.60 . sd. 0.05; p = 0.007). Cortical contact of the stem was also associated with high bone adaptation (14/25 shoulders, p = 0.001). The clinical outcome was not influenced by the radiological changes. Conclusion. Total shoulder arthroplasty using a short-stem humeral component resulted in good clinical outcomes with no evidence of loosening. However, approximately 40% of the shoulders developed substantial bone loss in the proximal humerus at between four and seven years of follow-up. Cite this article: Bone Joint J 2018;100-B:603–9


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 751 - 755
1 Jun 2006
Gerber C Lingenfelter EJ Reischl N Sukthankar A

We compared six patients with a mean age of 70 years (49 to 80) with severe bilateral, painful glenohumeral joint destruction who underwent a single-stage bilateral total shoulder replacement, with eight patients of mean age 61 years (22 to 89) who underwent bilateral total shoulder replacement in two stages, at a mean interval of 18 months (6 to 43). The overall function, pain and strength improved significantly in both groups. The subjective shoulder value, relative Constant score, active external rotation and the strength were improved significantly more in the single-stage group. Active elevation, abduction and overall function improved, significantly more in the single-stage group. Both the total duration of hospitalisation and the time off work per shoulder were substantially shorter in the single-stage group. The overall rate of complication was lower in the single-stage group. Our findings indicated that single-stage bilateral total shoulder replacement yielded significantly better clinical results with shorter hospitalisation and rehabilitation than staged replacement, and was not associated with any increase in complications


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims

Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).

Methods

A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1125 - 1132
1 Oct 2024
Luengo-Alonso G Valencia M Martinez-Catalan N Delgado C Calvo E

Aims

The prevalence of osteoarthritis (OA) associated with instability of the shoulder ranges between 4% and 60%. Articular cartilage is, however, routinely assessed in these patients using radiographs or scans (2D or 3D), with little opportunity to record early signs of cartilage damage. The aim of this study was to assess the prevalence and localization of chondral lesions and synovial damage in patients undergoing arthroscopic surgery for instablility of the shoulder, in order to classify them and to identify risk factors for the development of glenohumeral OA.

Methods

A total of 140 shoulders in 140 patients with a mean age of 28.5 years (15 to 55), who underwent arthroscopic treatment for recurrent glenohumeral instability, were included. The prevalence and distribution of chondral lesions and synovial damage were analyzed and graded into stages according to the division of the humeral head and glenoid into quadrants. The following factors that might affect the prevalence and severity of chondral damage were recorded: sex, dominance, age, age at the time of the first dislocation, number of dislocations, time between the first dislocation and surgery, preoperative sporting activity, Beighton score, type of instability, and joint laxity.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims

This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate.

Methods

We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 668 - 678
1 Jun 2023
Friedman RJ Boettcher ML Grey S Flurin P Wright TW Zuckerman JD Eichinger JK Roche C

Aims

The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system.

Methods

We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217).


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 3 - 5
1 Jan 2022
Rajasekaran RB Ashford R Stevenson JD Pollock R Rankin KS Patton JT Gupta S Cosker TDA


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 394 - 400
1 Mar 2022
Lee KJ Kim YT Choi M Kim SH

Aims

The aim of this study was to compare the characteristics and outcomes of L-shaped and reverse L-shaped rotator cuff tears.

Methods

A total of 82 shoulders (81 patients) after arthroscopic rotator cuff repair were retrospectively enrolled. The mean age of the patients was 62 years (SD 6), 33 shoulders (40.2%) were in male patients, and 57 shoulders (69.5%) were the right shoulder. Of these, 36 shoulders had an L-shaped tear (group L) and 46 had a reverse L-shaped tear (group RL). Both groups were compared regarding characteristics, pre- and postoperative pain, and functional outcomes. Muscle status was assessed by preoperative MRI, and re-tear rates by postoperative ultrasonography or MRI.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 361 - 366
1 May 1989
Watson M

Thirty-three patients with impingement syndrome of the rotator cuff were studied before and at operation. It was shown that the rotator cuff lengthens and twists during elevation of the arm. Elevation is achieved by early glenohumeral abduction and continuous flexion and external rotation. The range of free rotation at the glenohumeral joint diminishes progressively during elevation. Rotator cuff impingement occurs towards the end of the early glenohumeral abduction. Excision arthroplasty of the acromioclavicular joint and anterior acromioplasty is highly effective for impingement under the acromion, but only moderately effective where impingement is under the acromioclavicular joint


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 69 - 74
1 Jan 2001
Gagey OJ Gagey N

We studied 100 fresh human shoulders in cadavers (mean age 76 years), and the range of passive abduction (RPA) in 100 volunteers with normal shoulders and in 90 patients with instability of the joint, over a period of six years. The anatomical and clinical findings showed that passive abduction occurs within the glenohumeral joint only, is controlled by the inferior glenohumeral ligament and has a constant value in 95% of both shoulders in normal subjects. In patients with instability, 85% showed an RPA of over 105° with 90° in the contralateral shoulder. In the remaining patients a strongly positive apprehension test suggested a diagnosis of instability. An RPA of more than 105° is associated with lengthening and laxity of the inferior glenohumeral ligament


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 76 - 82
1 Jan 2022
ten Brinke B Hesseling B Eygendaal D Hoelen MA Mathijssen NMC

Aims

Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes.

Methods

In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 843 - 845
1 Sep 1990
Browne A Hoffmeyer P Tanaka S An K Morrey B

We studied the position and rotational changes associated with elevation of the glenohumeral joint, using a three-dimensional magnetic-field tracking system on nine fresh cadaveric shoulders. The plane of maximal arm elevation was shown to occur 23 degrees anterior to the plane of the scapula. Elevation in any plane anterior to the scapula required external humeral rotation, and maximal elevation was associated with approximately 35 degrees of external humeral rotation. Conversely, internal rotation was necessary for increased elevation posterior to the plane of the scapula. The observed effects of this rotation were to clear the humeral tuberosity from abutting beneath the acromion and to relax the inferior capsular ligamentous constraints. Measurement of the obligatory humeral rotation required for maximal elevation helps to explain the relationship of the limited elevation seen in adhesive capsulitis and after operations which limit external rotation


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 991 - 997
1 Sep 2004
Scheibel M Bartl C Magosch P Lichtenberg S Habermeyer P

We performed eight osteochondral autologous transplantations from the knee joint to the shoulder. All patients (six men, two women; mean age 43.1 years) were documented prospectively. In each patient the stage of the osteochondral lesion was Outerbridge grade IV with a mean size of the affected area of 150 mm. 2. All patients were assessed by using the Constant score for the shoulder and the Lysholm score for the knee. Standard radiographs, magnetic resonance imaging and second-look arthroscopy were used to assess the presence of glenohumeral osteoarthritis and the integrity of the grafts. After a mean of 32.6 months (8 to 47), the mean Constant score increased significantly. Magnetic resonance imaging revealed good osseointegration of the osteochondral plugs and congruent articular cartilage at the transplantation site in all but one patient. Second-look arthroscopy performed in two cases revealed a macroscopically good integration of the autograft with an intact articular surface. Osteochondral autologous transplantation in the shoulder appears to offer good clinical results for treating full-thickness osteochondral lesions of the glenohumeral joint. However, our study suggests that the development of osteoarthritis and the progression of pre-existing osteoarthritic changes cannot be altered by this technique


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 834 - 836
1 Sep 1994
Itoi E Newman Kuechle D Morrey B An K

The stabilising effects on the glenohumeral joint of each of the rotator-cuff muscles and of the biceps were studied with the arm in abduction and external rotation in 13 cadaver shoulders. The muscles were loaded one at a time with forces proportional to their cross-sectional areas. We recorded the positions of the humeral head before and after the application to the humerus of an anterior force of 1.5 kg. When the capsule was intact, the anterior displacement with the subscapularis loaded was significantly larger than with the other muscles loaded (p = 0.0009). With the capsule vented, the displacement with the biceps loaded was significantly smaller than that with the subscapularis loaded (p = 0.0052). After creating an imitation Bankart lesion, the displacement with the biceps loaded was significantly less than with any of the rotator-cuff muscles loaded (p = 0.0132). We conclude that in the intact shoulder, the subscapularis is the least important anterior stabiliser, and that the biceps becomes more important than the rotator-cuff muscles as stability from the capsuloligamentous structure decreases. Strengthening of the biceps as well as the rotator-cuff muscles should be part of the rehabilitation programme for anterior shoulder instability


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 402 - 405
1 May 1991
Zuckerman J Leblanc J Choueka J Kummer F

A cadaver study was performed to determine the effect of arm position and capsular release on rotator cuff repair. Artificial defects were made in the rotator cuff to include only the supraspinatus (small) or both supraspinatus and infraspinatus (large). The defects were repaired in a standard manner with the shoulder abducted 30 degrees at the glenohumeral joint. Strain gauges were placed on the lateral cortex of the greater tuberosity and measurements were recorded in 36 different combinations of abduction, flexion/extension, and medial/lateral rotation. Readings were obtained before and after capsular release. With small tears, tension in the repair increased significantly with movement from 30 degrees to 15 degrees of abduction (p < 0.01) but was minimally affected by changes in flexion or rotation. Capsular release significantly reduced the force (p < 0.01) at 0 degree and 15 degrees abduction. For large tears, abduction of 30 degrees or more with lateral rotation and extension consistently produced the lowest values. Capsular release resulted in 30% less force at 0 degree abduction (p < 0.05)


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 58 - 64
1 Jan 2004
te Slaa RL Wijffels MPJM Brand R Marti RK

We have studied 105 patients with 107 acute, primary, dislocations of the glenohumeral joint seen between January 1, 1991 and July 1, 1994. The mean time of follow-up was 71 months (46 to 91). In 34% the injury occurred during a sports activity and in 28% at home. The bias toward sport was even greater in patients less than 40 years of age, and in men. In patients older than 40 years of age, and in women, the dislocation occurred more often at home. The overall probability of recurrence within four years was 26%. Age was the most significant prognostic factor in recurrence which took place in 64% of patients less than 20 years of age and in 6% of those older than 40 years. Statistically, there was no difference between the rates of recurrence in patients who were active in sport and those who were not. The mean Rowe score for the whole group was 87 (15 to 100). Associated fractures were found in 20 patients (19%) and nerve injuries in 22 (21%). None of those in whom a fracture of the greater tuberosity was seen subsequently suffered a recurrent dislocation. At follow-up we found that 36 patients (34%) had not returned to their former employment but in only 2% was this owing to the injured shoulder


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1056 - 1062
1 Sep 2001
Bono CM Renard R Levine RG Levy AS

Using a dynamic biomechanical model of malunion of the shoulder, we have determined the change in deltoid force required for abduction with various combinations of superior and posterior displacement of fractures of the greater tuberosity of the humerus. We tested eight fresh human cadaver shoulders in a dynamic shoulder-testing apparatus during cycles of glenohumeral abduction from 0° to 90°. The greater tuberosities were osteotomised and stabilised to represent malunion with combinations of superior and posterior displacements of 1 cm and less. The peak force was measured for each displacement in each specimen and statistically compared with values of no displacement using a repeated-measures analysis of variance. The abduction force was significantly increased by 16% (p = 0.006) and 27% (p = 0.0001) by superior displacements of 0.5 cm and 1 cm, respectively, while combined superior and posterior displacement of 1 cm gave an increase in force of 29% (p = 0.001). While treatment criteria for acceptable residual displacement of the greater tuberosity are widely used, there is little information on the direct biomechanical effects of displacement on shoulder mechanics. Although the results of conservative treatment are influenced by a number of factors, including associated injuries, rehabilitation and the pre-existing function of the shoulder, our data suggest that small amounts of residual displacement may alter the balance of forces required to elevate the arm at the glenohumeral joint


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 546 - 550
1 Jul 1993
Itoi E Kuechle D Newman Morrey B An K

We studied the contributions of the long and short heads of the biceps (LHB, SHB) to anterior stability in 13 cadaver shoulders. The LHB and SHB were replaced by spring devices and translation tests at 90 degrees abduction of the arm were performed by applying a 1.5 kg anterior force. The position of the humeral head was monitored by an electromagnetic tracking device with or without an anterior translational force; with 0 kg, 1.5 kg or 3 kg loads applied on either LHB or SHB tendons in 60 degrees, 90 degrees or 120 degrees of external rotation; and with the capsule intact, vented, or damaged by a Bankart lesion. The anterior displacement of the humeral head under 1.5 kg force was significantly decreased by both the LHB and SHB loading in all capsular conditions when the arm was in 60 degrees or 90 degrees of external rotation. At 120 degrees of external rotation, anterior displacement was significantly decreased by LHB and SHB loading only when there was a Bankart lesion. We conclude that LHB and SHB have similar functions as anterior stabilizers of the glenohumeral joint with the arm in abduction and external rotation, and that their role increases as shoulder stability decreases. Both heads of the biceps have been shown to have a stabilising function in resisting anterior head displacement, and consideration should therefore be given to strengthening the biceps during rehabilitation programmes for chronic anterior instability of the shoulder


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 406 - 413
1 May 1999
McMahon PJ Dettling J Sandusky MD Tibone JE Lee TQ

Surgical treatment for traumatic, anterior glenohumeral instability requires repair of the anterior band of the inferior glenohumeral ligament, usually at the site of glenoid insertion, often combined with capsuloligamentous plication. In this study, we determined the mechanical properties of this ligament and the precise anatomy of its insertion into the glenoid in fresh-frozen glenohumeral joints of cadavers. Strength was measured by tensile testing of the glenoid-soft-tissue-humerus (G-ST-H) complex. Two other specimens of the complex were frozen in the position of apprehension, serially sectioned perpendicular to the plane containing the anterior and posterior rims of the glenoid, and stained with Toluidine Blue. On tensile testing, eight G-ST-H complexes failed at the site of the glenoid insertion, representing a Bankart lesion, two at the insertion into the humerus, and two at the midsubstance. For those which failed at the glenoid attachment the mean yield load was 491.0 N and the mean ultimate load, 585.0 N. At the glenoid region, stress at yield was 7.8 ± 1.3 MPa and stress at failure, 9.2 ± 1.5 MPa. The permanent deformation, defined as the difference between yield and ultimate deformation, was only 2.3 ± 0.8 mm. The strain at yield was 13.0 ± 0.7% and at failure, 15.4 ± 1.2%; therefore permanent strain was only 2.4 ± 1.1%. Histological examination showed that there were two attachments of the anterior band of the inferior glenohumeral ligament at the site of the glenoid insertion. In one, poorly organised collagen fibres inserted into the labrum. In the other, dense collagen fibres were attached to the front of the neck of the glenoid


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1292 - 1300
1 Jul 2021
Märtens N Heinze M Awiszus F Bertrand J Lohmann CH Berth A

Aims

The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed anatomical shoulder prostheses for treatment of osteoarthritis and to analyze radiological bone changes around the implants during follow-up.

Methods

A total of 161 patients treated with either a stemmed or a stemless shoulder arthroplasty for primary osteoarthritis of the shoulder were evaluated with a mean follow-up of 118 months (102 to 158). The Constant score (CS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, and active range of motion (ROM) were recorded. Radiological analysis for bone adaptations was performed by plain radiographs. A Kaplan-Meier survivorship analysis was calculated and complications were noted.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 246 - 253
1 Feb 2020
Alluri RK Lightdale-Miric N Meisel E Kim G Kaplan J Bougioukli S Stevanovic M

Aims

To describe and analyze the mid-term functional outcomes of a large series of patients who underwent the Hoffer procedure for brachial plexus birth palsy (BPBP).

Methods

All patients who underwent the Hoffer procedure with minimum two-year follow-up were retrospectively reviewed. Active shoulder range of movement (ROM), aggregate modified Mallet classification scores, Hospital for Sick Children Active Movement Scale (AMS) scores, and/or Toronto Test Scores were used to assess functional outcomes. Subgroup analysis based on age and level of injury was performed. Risk factors for subsequent humeral derotational osteotomy and other complications were also assessed. A total of 107 patients, average age 3.9 years (1.6 to 13) and 59% female, were included in the study with mean 68 months (24 to 194) follow-up.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1600 - 1608
1 Dec 2018
Bouaicha S Ernstbrunner L Jud L Meyer DC Snedeker JG Bachmann E

Aims

In patients with a rotator cuff tear, tear pattern and tendon involvement are known risk factors for the development of pseudoparalysis of the shoulder. It remains unclear, however, why similar tears often have very different functional consequences. The present study hypothesizes that individual shoulder anatomy, specifically the moment arms (MAs) of the rotator cuff (RC) and the deltoid muscle, as well as their relative recruitment during shoulder abduction, plays a central role in pseudoparalysis.

Materials and Methods

Biomechanical and clinical analyses of the pseudoparalytic shoulder were conducted based on the ratio of the RC/deltoid MAs, which were used to define a novel anatomical descriptor called the Shoulder Abduction Moment (SAM) index. The SAM index is the ratio of the radii of two concentric spheres based on the centre of rotation of the joint. One sphere captures the humeral head (numerator) and the other the deltoid origin of the acromion (denominator). A computational rigid body simulation was used to establish the functional link between the SAM index and a potential predisposition for pseudoparalysis. A retrospective radiological validation study based on these measures was also undertaken using two cohorts with and without pseudoparalysis and massive RC tears.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 606 - 610
1 May 2020
Nicholson JA Slader B Martindale A Mckie S Robinson CM

Aims

The primary aim of this study was to evaluate the efficacy of distension arthrography in the treatment of adhesive capsulitis of the shoulder. The secondary aim was to assess which patient and procedural factors predicted the recurrence of symptoms after the procedure.

Methods

All patients referred to our shoulder clinic over a ten-year period, between 2008 and 2018, with a clinical diagnosis of capsulitis and symptoms persisting for more than six months, were offered treatment with a distension arthrogram. All procedures were performed by one of five musculoskeletal radiologists, with a combination of steroid, local anaesthetic, and a distention volume of 10 ml, 30 ml, or 50 ml. Patient demographics, procedural details, recurrence of symptoms, and the need for further intervention were evaluated.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 360 - 364
1 Mar 2020
Jenkins PJ Stirling PHC Ireland J Elias-Jones C Brooksbank AJ

Aims

The aim of this study was to examine the recent trend in delivery of arthroscopic subacromial decompression (ASD) in Scotland and to determine if this varies by geographical location.

Methods

Scottish Morbidity Records were reviewed retrospectively between March 2014 and April 2018 to identify records for every admission to each NHS hospital. The Office of Population Censuses and Surveys (OPCS-4) surgical codes were used to identify patients undergoing primary ASD. Patients who underwent acromioclavicular joint excision (ACJE) and rotator cuff repair (RCR) were identified and grouped separately. Procedure rates were age and sex standardized against the European standard population.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 365 - 370
1 Mar 2020
Min KS Fox HM Bedi A Walch G Warner JJP

Aims

Patient-specific instrumentation has been shown to increase a surgeon’s precision and accuracy in placing the glenoid component in shoulder arthroplasty. There is, however, little available information about the use of patient-specific planning (PSP) tools for this operation. It is not known how these tools alter the decision-making patterns of shoulder surgeons. The aim of this study was to investigate whether PSP, when compared with the use of plain radiographs or select static CT images, influences the understanding of glenoid pathology and surgical planning.

Methods

A case-based survey presented surgeons with a patient’s history, physical examination, and, sequentially, radiographs, select static CT images, and PSP with a 3D imaging program. For each imaging modality, the surgeons were asked to identify the Walch classification of the glenoid and to propose the surgical treatment. The participating surgeons were grouped according to the annual volume of shoulder arthroplasties that they undertook, and responses were compared with the recommendations of two experts.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 64 - 71
1 Jan 2020
Tsuda Y Fujiwara T Stevenson JD Parry MC Tillman R Abudu A

Aims

The purpose of this study was to report the long-term results of extendable endoprostheses of the humerus in children after the resection of a bone sarcoma.

Methods

A total of 35 consecutive patients treated with extendable endoprosthetic replacement of the humerus in children were included. There were 17 boys and 18 girls in the series with a median age at the time of initial surgery of nine years (interquartile range (IQR) 7 to 11).


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1074 - 1079
1 Aug 2018
Paul R Knowles N Chaoui J Gauci M Ferreira L Walch G Athwal GS

Aims

The Walch Type C dysplastic glenoid is characterized by excessive retroversion. This anatomical study describes its morphology.

Patients and Methods

A total of 29 shoulders with a dysplastic glenoid were analyzed. CT was used to measure retroversion, inclination, height, width, radius-of-curvature, surface area, depth, subluxation of the humeral head and the Goutallier classification of fatty infiltration. The severity of dysplasia and deficiency of the posterior rim of the glenoid were recorded.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 124 - 131
1 Feb 2019
Isaacs J Cochran AR

Abstract

Nerve transfer has become a common and often effective reconstructive strategy for proximal and complex peripheral nerve injuries of the upper limb. This case-based discussion explores the principles and potential benefits of nerve transfer surgery and offers in-depth discussion of several established and valuable techniques including: motor transfer for elbow flexion after musculocutaneous nerve injury, deltoid reanimation for axillary nerve palsy, intrinsic re-innervation following proximal ulnar nerve repair, and critical sensory recovery despite non-reconstructable median nerve lesions.


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1067 - 1072
1 Aug 2017
Booker SJ Boyd M Gallacher S Evans JP Auckland C Kitson J Thomas W Smith CD

Aims

Our aim was to investigate the prevalence of Propionibacterium (P.) acnes in the subcutaneous fat and capsule of patients undergoing shoulder surgery for frozen shoulder or instability.

Patients and Methods

A total of 46 patients undergoing either an arthroscopic capsular release or stabilisation had biopsies taken from the subcutaneous fat and capsule of the shoulder at the time of surgery. These samples were sent for culture in enrichment, and also for Nucleic Acid Amplification testing. The prevalence of P. acnes and other microbes was recorded. Fisher's exact test of binary variables was used to calculate the association with significance set at p < 0.05. Assessment of influence of independent variables including a pre-operative glenohumeral injection, fat colonisation and gender, was undertaken using binary linear regression.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 318 - 323
1 Mar 2018
Raiss P Alami G Bruckner T Magosch P Habermeyer P Boileau P Walch G

Aims

The aim of this study was to analyze the results of reverse shoulder arthroplasty (RSA) in patients with type 1 sequelae of a fracture of the proximal humerus in association with rotator cuff deficiency or severe stiffness of the shoulder.

Patients and Methods

A total of 38 patients were included: 28 women and ten men. Their mean age at the time of arthroplasty was 73 years (54 to 91). Before the RSA, 18 patients had been treated with open reduction and internal fixation following a fracture. A total of 22 patients had a rotator cuff tear and 11 had severe stiffness of the shoulder with < 0° of external rotation. The mean follow-up was 4.3 years (1.5 to 10). The Constant score and the range of movement of the shoulder were recorded preoperatively and at final follow-up.

Preoperatively, radiographs in two planes were performed, as well as CT or arthro-CT scans; radiographs were also performed at final follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 68 - 74
1 Jan 2019
Klemt C Toderita D Nolte D Di Federico E Reilly P Bull AMJ

Aims

Patients with recurrent anterior dislocation of the shoulder commonly have an anterior osseous defect of the glenoid. Once the defect reaches a critical size, stability may be restored by bone grafting. The critical size of this defect under non-physiological loading conditions has previously been identified as 20% of the length of the glenoid. As the stability of the shoulder is load-dependent, with higher joint forces leading to a loss of stability, the aim of this study was to determine the critical size of an osseous defect that leads to further anterior instability of the shoulder under physiological loading despite a Bankart repair.

Patients and Methods

Two finite element (FE) models were used to determine the risk of dislocation of the shoulder during 30 activities of daily living (ADLs) for the intact glenoid and after creating anterior osseous defects of increasing magnitudes. A Bankart repair was simulated for each size of defect, and the shoulder was tested under loading conditions that replicate in vivo forces during these ADLs. The critical size of a defect was defined as the smallest osseous defect that leads to dislocation.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 338 - 345
1 Mar 2018
Watkins CEL Elson DW Harrison JWK Pooley J

Aim

The aim of this study was to report the long-term outcome and implant survival of the lateral resurfacing elbow (LRE) arthroplasty in the treatment of elbow arthritis.

Patients and Methods

We reviewed a consecutive series of 27 patients (30 elbows) who underwent LRE arthroplasty between December 2005 and January 2008. There were 15 women and 12 men, with a mean age of 61 years (25 to 82). The diagnosis was primary hypotrophic osteoarthritis (OA) in 12 patients (14 elbows), post-traumatic osteoarthritis (PTOA) in five (five elbows) and rheumatoid arthritis (RA) in ten patients (11 elbows). The mean clinical outcome scores including the Mayo Elbow Performance Score (MEPS), the American Shoulder and Elbow Surgeons elbow score (ASES-e), the mean range of movement and the radiological outcome were recorded at three, six and 12 months and at a mean final follow-up of 8.3 years (7.3 to 9.4). A one sample t-test comparing pre and postoperative values, and survival analysis using the Kaplan–Meier method were undertaken.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 309 - 317
1 Mar 2018
Kolk A Henseler JF Overes FJ Nagels J Nelissen RGHH

Aims

Since long-term outcome of teres major tendon transfer surgery for irreparable posterosuperior rotator cuff (RC) tears is largely unknown, the primary aim of this study was to evaluate the long-term outcome of the teres major transfer. We also aimed to report on the results of a cohort of patients with a similar indication for surgery that underwent a latissimus dorsi tendon transfer.

Patients and Methods

In this prospective cohort study, we reported on the long-term results of 20 consecutive patients with a teres major tendon transfer for irreparable massive posterosuperior RC tears. Additionally, we reported on the results of the latissimus dorsi tendon transfer (n = 19). The mean age was 60 years (47 to 77). Outcomes included the Constant score (CS), and pain at rest and during movement using the Visual Analogue Scale (VAS).


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1090 - 1095
1 Aug 2015
Urita A Funakoshi T Suenaga N Oizumi N Iwasaki N

This pilot study reports the clinical outcomes of a combination of partial subscapularis tendon transfer and small-head hemiarthroplasty in patients with rotatator cuff arthropathy. A total of 30 patients (30 shoulders; eight men and 22 women) with a mean age of 74 years (55 to 84) were assessed at a mean follow-up of 31 months (24 to 60). The inclusion criteria were painful cuff tear arthropathy with normal deltoid function and a non-degenerative subscapularis muscle and tendon and a preserved teres minor.

Outcome was assessed using the University of California Los Angeles score, the Japanese Orthopaedic Association score, and the Oxford Shoulder Score. Radiographic measurements included the centre of rotation distance and the length of the deltoid.

All clinical scores were significantly improved post-operatively. The active flexion and external rotation improved significantly at the most recent follow-up (p < 0.035). Although the mean centre of rotation distance changed significantly (p < 0.001), the mean length of the deltoid did not change significantly from the pre-operative value (p = 0.29). The change in the length of the deltoid with < 100° flexion was significantly less than that with > 100° (p < 0.001).

Progressive erosion of the glenoid was seen in four patients. No patient required revision or further surgery.

A combination of partial subscapularis tendon transfer and small-head hemiarthroplasty effectively restored function and relieved pain in patients with rotator cuff arthropathy.

Cite this article: 2015;97-B:1090–5.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 967 - 972
1 Jul 2015
Hussey MM Hussey SE Mighell MA

Failed internal fixation of a fracture of the proximal humerus produces many challenges with limited surgical options. The aim of this study was to evaluate the clinical outcomes after the use of a reverse shoulder arthroplasty under these circumstances. Between 2007 and 2012, 19 patients (15 women and four men, mean age 66 years; 52 to 82) with failed internal fixation after a proximal humeral fracture, underwent implant removal and reverse shoulder arthroplasty (RSA). The mean follow-up was 36 months (25 to 60). The mean American Shoulder and Elbow Score improved from 27.8 to 50.1 (p = 0.019). The mean Simple Shoulder Test score improved from 0.7 to 3.2 (p = 0.020), and the mean visual analogue scale for pain improved from 6.8 to 4.3 (p = 0.012). Mean forward flexion improved from 58.7° to 101.1° (p < 0.001), mean abduction from 58.7° to 89.1° (p = 0.012), mean external rotation from 10.7° to 23.1° (p = 0.043) and mean internal rotation from buttocks to L4 (p = 0.034). A major complication was recorded in five patients (26%) (one intra-operative fracture, loosening of the humeral component in two and two peri-prosthetic fractures). A total of 15 patients (79%) rated their outcome as excellent or good, one (5%) as satisfactory, and three (16%) as unsatisfactory.

An improvement in outcomes and pain can be expected when performing a RSA as a salvage procedure after failed internal fixation of a fracture of the proximal humerus. Patients should be cautioned about the possibility for major complications following this technically demanding procedure.

Cite this article: Bone Joint J 2015;97-B:967–72.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 806 - 811
1 Jun 2017
Takahashi N Sugaya H Matsuki K Miyauchi H Matsumoto M Tokai M Onishi K Hoshika S Ueda Y

Aims

The aim of this study was to assess hypertrophy of the extra-articular tendon of the long head of biceps (LHB) in patients with a rotator cuff tear.

Patients and Methods

The study involved 638 shoulders in 334 patients (175 men, 159 women, mean age 62.6 years; 25 to 81) with unilateral symptomatic rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon in the bicipital groove was measured pre-operatively in both shoulders using ultrasound. There were 154 asymptomatic rotator cuff tears in the contralateral shoulder. Comparisons were made between those with a symptomatic tear, an asymptomatic tear and those with no rotator cuff tear. In the affected shoulders, the CSAs were compared in relation to the location and size of the rotator cuff tear.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 209 - 217
1 Feb 2016
Satbhai NG Doi K Hattori Y Sakamoto S

Aims

Between 2002 and 2011, 81 patients with a traumatic total brachial plexus injury underwent reconstruction by double free muscle transfer (DFMT, 47 cases), single muscle transfer (SMT, 16 cases) or nerve transfers (NT, 18 cases).

Methods

They were evaluated for functional outcome and quality of life (QoL) using the Disability of Arm, Shoulder and Hand questionnaire, both pre- and post-operatively. The three groups were compared and followed-up for at least 24 months.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 684 - 690
1 May 2014
Xie L X. D. T Yang RL Guo W

We retrospectively reviewed the outcomes of 33 consecutive patients who had undergone an extra-articular, total or partial scapulectomy for a malignant tumour of the shoulder girdle between 1 July 2001 and 30 September 2013. Of these, 26 had tumours which originated in the scapula or the adjacent soft tissue and underwent a classic Tikhoff–Linberg procedure, while seven with tumours arising from the proximal humerus were treated with a modified Tikhoff-Linberg operation. We used a Ligament Advanced Reinforcement System for soft-tissue reconstruction in nine patients, but not in the other 24.

The mean Musculoskeletal Tumor Society score (MSTS) was 17.6 (95% confidence interval (CI) 15.9 to 19.4); 17.6 (95% CI 15.5 to 19.6) after the classic Tikhoff–Linberg procedure and 18.1 (95% CI 13.8 to 22.3) after the modified Tikhoff–Linberg procedure. Patients who had undergone a LARS soft-tissue reconstruction had a mean score of 18.6 (95% (CI) 13.9 to 22.4) compared with 17.2 (95% CI 15.5 to 19.0) for those who did not.

The Tikhoff–Linberg procedure is a useful method for wide resection of a malignant tumour of the shoulder girdle which helps to preserve hand and elbow function. The method of soft-tissue reconstruction has no effect on functional outcome.

Cite this article: Bone Joint J 2014;96-B:684–90.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1080 - 1085
1 Aug 2016
Gauci MO Boileau P Baba M Chaoui J Walch G

Aims

Patient-specific glenoid guides (PSGs) claim an improvement in accuracy and reproducibility of the positioning of components in total shoulder arthroplasty (TSA). The results have not yet been confirmed in a prospective clinical trial. Our aim was to assess whether the use of PSGs in patients with osteoarthritis of the shoulder would allow accurate and reliable implantation of the glenoid component.

Patients and Methods

A total of 17 patients (three men and 14 women) with a mean age of 71 years (53 to 81) awaiting TSA were enrolled in the study. Pre- and post-operative version and inclination of the glenoid were measured on CT scans, using 3D planning automatic software. During surgery, a congruent 3D-printed PSG was applied onto the glenoid surface, thus determining the entry point and orientation of the central guide wire used for reaming the glenoid and the introduction of the component. Manual segmentation was performed on post-operative CT scans to compare the planned and the actual position of the entry point (mm) and orientation of the component (°).


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1520 - 1524
1 Nov 2014
van der Zwaal P Pijls BG Thomassen BJW Lindenburg R Nelissen RGHH van de Sande MAJ

The purpose of this study was to evaluate the natural history of rheumatoid disease of the shoulder over an eight-year period. Our hypothesis was that progression of the disease is associated with a decrease in function with time.

A total of 22 patients (44 shoulders; 17 women, 5 men, (mean age 63)) with rheumatoid arthritis were followed for eight years. All shoulders were assessed using the Constant score, anteroposterior radiographs (Larsen score, Upward-Migration-Index (UMI)) and ultrasound (US). At final follow-up, the Short Form-36, disabilities of the arm, shoulder and hand (DASH) Score, erythrocyte sedimentation rate and use of anti-rheumatic medication were determined.

The mean Constant score was 72 points (50 to 88) at baseline and 69 points (25 to 100) at final follow-up. Radiological evaluation showed progressive destruction of the peri-articular structures with time. This progression of joint and rotator cuff destruction was significantly associated with the Constant score. However, at baseline only the extent of rotator cuff disease and the UMI could predict the Constant score at final follow-up.

A plain anteroposterior radiograph of the shoulder is sufficient to assess any progression of rheumatoid disease and to predict functional outcome in the long term by using the UMI as an indicator of rotator cuff degeneration.

Cite this article: Bone Joint J 2014;96-B:1520–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1049 - 1053
1 Aug 2009
Braunstein V Kirchhoff C Ockert B Sprecher CM Korner M Mutschler W Wiedemann E Biberthaler P

In 100 patients the fulcrum axis which is the line connecting the anterior tip of the coracoid and the posterolateral angle of the acromion, was used to position true anteroposterior radiographs of the shoulder. This method was then compared with the conventional radiological technique in a further 100 patients.

Three orthopaedic surgeons counted the number of images without overlap between the humeral head and glenoid and calculated the amount of the glenoid surface visible in each radiograph. The analysis was repeated for intraobserver reliability. The learning curves of both techniques were studied.

The amount of free visible glenoid space was significantly higher using the fulcrum-axis method (64 vs 31) and the comparable glenoid size increased significantly (8.56 vs 6.47). Thus the accuracy of the anteroposterior radiographs of the shoulder is impaired by using this technique. The intra and interobserver reliability showed a high consistency. No learning curve was observed for either technique.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 660 - 663
1 May 2013
Ghosh S Singh VK Jeyaseelan L Sinisi M Fox M

In adults with brachial plexus injuries, lack of active external rotation at the shoulder is one of the most common residual deficits, significantly compromising upper limb function. There is a paucity of evidence to address this complex issue. We present our experience of isolated latissimus dorsi (LD) muscle transfer to achieve active external rotation. This is a retrospective review of 24 adult post-traumatic plexopathy patients who underwent isolated latissimus dorsi muscle transfer to restore external rotation of the shoulder between 1997 and 2010. All patients were male with a mean age of 34 years (21 to 57). All the patients underwent isolated LD muscle transfer using a standard technique to correct external rotational deficit. Outcome was assessed for improvement in active external rotation, arc of movement, muscle strength and return to work. The mean improvement in active external rotation from neutral was 24° (10° to 50°). The mean increase in arc of rotation was 52° (38° to 55°). Mean power of the external rotators was 3.5 Medical Research Council (MRC) grades (2 to 5).

A total of 21 patients (88%) were back in work by the time of last follow up. Of these, 13 had returned to their pre-injury occupation. Isolated latissimus dorsi muscle transfer provides a simple and reliable method of restoring useful active external rotation in adults with brachial plexus injuries with internal rotational deformity.

Cite this article: Bone Joint J 2013;95-B:660–3.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1059 - 1065
1 Aug 2008
Elhassan B Ozbaydar M Massimini D Diller D Higgins L Warner JJP

Transfer of pectoralis major has evolved as the most favoured option for the management of the difficult problem of irreparable tears of subscapularis. We describe our experience with this technique in 30 patients divided into three groups. Group I comprised 11 patients with a failed procedure for instability of the shoulder, group II included eight with a failed shoulder replacement and group III, 11 with a massive tear of the rotator cuff. All underwent transfer of the sternal head of pectoralis major to restore the function of subscapularis.

At the latest follow-up pain had improved in seven of the 11 patients in groups I and III, but in only one of eight in group II. The subjective shoulder score improved in seven patients in group I, in one in group II and in six in group III. The mean Constant score improved from 40.9 points (28 to 50) in group I, 32.9 (17 to 47) in group II and 28.7 (20 to 42) in group III pre-operatively to 60.8 (28 to 89), 41.9 (24 to 73) and 52.3 (24 to 78), respectively.

Failure of the tendon transfer was highest in group II and was associated with pre-operative anterior subluxation of the humeral head. We conclude that in patients with irreparable rupture of subscapularis after shoulder replacement there is a high risk of failure of transfer of p?ctoralis major, particularly if there is pre-operative anterior subluxation of the humeral head.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 574 - 579
1 May 2014
Talbot CL Ring J Holt EM

We present a review of claims made to the NHS Litigation Authority (NHSLA) by patients with conditions affecting the shoulder and elbow, and identify areas of dissatisfaction and potential improvement. Between 1995 and 2012, the NHSLA recorded 811 claims related to the shoulder and elbow, 581 of which were settled. This comprised 364 shoulder (64%), and 217 elbow (36%) claims. A total of £18.2 million was paid out in settled claims. Overall diagnosis, mismanagement and intra-operative nerve injury were the most common reasons for litigation. The highest cost paid out resulted from claims dealing with incorrect, missed or delayed diagnosis, with just under £6 million paid out overall. Fractures and dislocations around the shoulder and elbow were common injuries in this category. All 11 claims following wrong-site surgery that were settled led to successful payouts.

This study highlights the diagnoses and procedures that need to be treated with particular vigilance. Having an awareness of the areas that lead to litigation in shoulder and elbow surgery will help to reduce inadvertent risks to patients and prevent dissatisfaction and possible litigation.

Cite this article: Bone Joint J 2014; 96-B:574–9.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 218 - 223
1 Feb 2016
Scalise J Jaczynski A Jacofsky M

Aims

The eccentric glenosphere was principally introduced into reverse shoulder arthroplasty to reduce the incidence of scapular notching. There is only limited information about the influence of its design on deltoid power and joint reaction forces.

The aim of our study was to investigate how the diameter and eccentricity of the glenosphere affect the biomechanics of the deltoid and the resultant joint reaction forces.

Methods

Different sizes of glenosphere and eccentricity were serially tested in ten cadaveric shoulders using a custom shoulder movement simulator.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 75 - 81
1 Jan 2014
Kukkonen J Joukainen A Lehtinen J Mattila KT Tuominen EKJ Kauko T Äärimaa V

We have compared three different methods of treating symptomatic non-traumatic tears of the supraspinatus tendon in patients above 55 years of age. A total of 180 shoulders (173 patients) with supraspinatus tendon tears were randomly allocated into one of three groups (each of 60 shoulders); physiotherapy (group 1), acromioplasty and physiotherapy (group 2) and rotator cuff repair, acromioplasty and physiotherapy (group 3). The Constant score was assessed and followed up by an independent observer pre-operatively and at three, six and twelve months after the intervention.

Of these, 167 shoulders were available for assessment at one year (follow-up rate of 92.8%). There were 55 shoulders in group 1 (24 in males and 31 in females, mean age 65 years (55 to 79)), 57 in group 2 (29 male and 28 female, mean age 65 years (55 to 79)) and 55 shoulders in group 3 (26 male and 29 female, mean age 65 years (55 to 81)). There were no between-group differences in the Constant score at final follow-up: 74.1 (sd 14.2), 77.2 (sd 13.0) and 77.9 (sd 12.1) in groups 1, 2 and 3, respectively (p = 0.34). The mean change in the Constant score was 17.0, 17.5, and 19.8, respectively (p = 0.34). These results suggest that at one-year follow-up, operative treatment is no better than conservative treatment with regard to non-traumatic supraspinatus tears, and that conservative treatment should be considered as the primary method of treatment for this condition.

Cite this article: Bone Joint J 2014;96-B:75–81.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 102 - 107
1 Jan 2011
Di Mascio L Chin K Fox M Sinisi M

We describe the early results of glenoplasty as part of the technique of operative reduction of posterior dislocation of the shoulder in 29 children with obstetric brachial plexus palsy. The mean age at operation was five years (1 to 18) and they were followed up for a mean of 34 months (12 to 67).

The mean Mallet score increased from 8 (5 to 13) to 12 (8 to 15) at final follow-up (p < 0.001). The mean passive forward flexion was increased by 18° (p = 0.017) and the mean passive abduction by 24° (p = 0.001). The mean passive lateral rotation also increased by 54° (p < 0.001), but passive medial rotation was reduced by a mean of only 7°. One patient required two further operations. Glenohumeral stability was achieved in all cases.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1106 - 1113
1 Aug 2013
Lädermann A Walch G Denard PJ Collin P Sirveaux F Favard L Edwards TB Kherad O Boileau P

The indications for reverse shoulder arthroplasty (RSA) continue to be expanded. Associated impairment of the deltoid muscle has been considered a contraindication to its use, as function of the RSA depends on the deltoid and impairment of the deltoid may increase the risk of dislocation. The aim of this retrospective study was to determine the functional outcome and risk of dislocation following the use of an RSA in patients with impaired deltoid function. Between 1999 and 2010, 49 patients (49 shoulders) with impairment of the deltoid underwent RSA and were reviewed at a mean of 38 months (12 to 142) post-operatively. There were nine post-operative complications (18%), including two dislocations. The mean forward elevation improved from 50° (sd 38; 0° to 150°) pre-operatively to 121° (sd 40; 0° to 170°) at final follow-up (p < 0.001). The mean Constant score improved from 24 (sd 12; 2 to 51) to 58 (sd 17; 16 to 83) (p < 0.001). The mean Single Assessment Numeric Evaluation score was 71 (sd 17; 10 to 95) and the rate of patient satisfaction was 98% (48 of 49) at final follow-up.

These results suggest that pre-operative deltoid impairment, in certain circumstances, is not an absolute contraindication to RSA. This form of treatment can yield reliable improvement in function without excessive risk of post-operative dislocation.

Cite this article: Bone Joint J 2013;95-B:1106–13.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 1 - 9
1 Jan 2012
Robinson CM Seah KTM Chee YH Hindle P Murray IR

Frozen shoulder is commonly encountered in general orthopaedic practice. It may arise spontaneously without an obvious predisposing cause, or be associated with a variety of local or systemic disorders. Diagnosis is based upon the recognition of the characteristic features of the pain, and selective limitation of passive external rotation. The macroscopic and histological features of the capsular contracture are well-defined, but the underlying pathological processes remain poorly understood. It may cause protracted disability, and imposes a considerable burden on health service resources. Most patients are still managed by physiotherapy in primary care, and only the more refractory cases are referred for specialist intervention. Targeted therapy is not possible and treatment remains predominantly symptomatic. However, over the last ten years, more active interventions that may shorten the clinical course, such as capsular distension arthrography and arthroscopic capsular release, have become more popular.

This review describes the clinical and pathological features of frozen shoulder. We also outline the current treatment options, review the published results and present our own treatment algorithm.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1410 - 1415
1 Oct 2010
Castagna A Randelli M Garofalo R Maradei L Giardella A Borroni M

Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using a new metal-backed glenoid component with a mean follow-up of 75.4 months (48 to 154).

Our implant differs from others because of its mechanism of fixation. It has a convex metal-backed bone interface and the main stabilising factor is a large hollow central peg. The patients were evaulated with standard radiographs and with the Constant Score, the Simple Shoulder Test and a visual analogue scale. All the scores improved and there was no loosening, no polyethylene-glenoid disassembly and no other implant-related complications.

We conclude that a metal-backed glenoid component is a good option in total shoulder replacement with no worse results than of those using a cemented all-polyethylene prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1390 - 1392
1 Oct 2006
Rhee KJ Kim KC Lee JK Hwang DS Shin HD Yang JY Kim YM

In a 41-year-old man, right-sided infraspinatus muscle weakness was associated with compression of the suprascapular nerve caused by a spinoglenoid ganglion cyst. The lesion was confirmed using electromyography and MRI. In addition, arthroscopy showed an incomplete discoid labrum. The free inner edge of the labrum was removed as in a meniscectomy of a discoid meniscus in the knee joint. Arthroscopic decompression of the cyst was performed through a juxtaglenoid capsulotomy which was left open. Neurological function recovered completely.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 751 - 756
1 Jun 2008
Terrier A Reist A Merlini F Farron A

Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active abduction was simulated from 0° to 150° of elevation. With the anatomical prosthesis, the joint force almost reached the equivalence of body weight. The joint force was half this for the reversed prosthesis. The direction of force was much more vertically aligned for the reverse prosthesis, in the first 90° of abduction. With the reversed prosthesis, abduction was possible without rotator cuff muscles and required 20% less deltoid force to achieve it.

This force analysis confirms the potential mechanical advantage of reversed prostheses when rotator cuff muscles are deficient.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 434 - 441
1 Apr 2015
Shabani F Farrier AJ Krishnaiyan R Hunt C Uzoigwe CE Venkatesan M

Drug therapy forms an integral part of the management of many orthopaedic conditions. However, many medicines can produce serious adverse reactions if prescribed inappropriately, either alone or in combination with other drugs. Often these hazards are not appreciated. In response to this, the European Union recently issued legislation regarding safety measures which member states must adopt to minimise the risk of errors of medication.

In March 2014 the Medicines and Healthcare products Regulatory Agency and NHS England released a Patient Safety Alert initiative focussed on errors of medication. There have been similar initiatives in the United States under the auspices of The National Coordinating Council for Medication Error and The Joint Commission on the Accreditation of Healthcare Organizations. These initiatives have highlighted the importance of informing and educating clinicians.

Here, we discuss common drug interactions and contra-indications in orthopaedic practice. This is germane to safe and effective clinical care.

Cite this article: Bone Joint J 2015;97-B:434–41.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1632 - 1637
1 Dec 2009
Sonnabend DH Young AA

While the evolution of the bony skeleton of the shoulder girdle is well described, there is little information regarding the soft tissues, in particular of the rotator cuff. We dissected the shoulders of 23 different species and compared the anatomical features of the tendons of the rotator cuff. The alignment and orientation of the collagen fibres of some of the tendons were also examined histologically. The behaviour of the relevant species was studied, with particular reference to the extent and frequency of forward-reaching and overhead activity of the forelimb.

In quadrupedal species, the tendons of supraspinatus, infraspinatus and teres minor were seen to insert into the greater tuberosity of the humerus separately. They therefore did not form a true rotator cuff with blending of the tendons. This was only found in advanced primates and in one unusual species, the tree kangaroo. These findings support the suggestion that the appearance of the rotator cuff in the evolutionary process parallels anatomical adaptation to regular overhead activity and the increased use of the arm away from the sagittal plane.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1355 - 1358
1 Oct 2014
Mehta SS Singh HP Pandey R

Our aim was to compare the outcome of arthroscopic release for frozen shoulder in patients with and without diabetes. We prospectively compared the outcome in 21 patients with and 21 patients without diabetes, two years post-operatively. The modified Constant score was used as the outcome measure. The mean age of the patients was 54.5 years (48 to 65; male:female ratio: 18:24), the mean pre-operative duration of symptoms was 8.3 months (6 to 13) and the mean pre-operative modified Constant scores were 36.6 (standard deviation (sd) 4.6) and 38.4 (sd 5.7) in the diabetic and non-diabetic groups, respectively. The mean modified Constant scores at six weeks, six months and two years post-operatively in the diabetics were 55. 6 (sd 4.7), 67. 4 (sd 5.6) and 84. 4 (sd 6.8), respectively; and in the non-diabetics 66.8 (sd 4.5), 79.6 (sd 3.8) and 88.6 (sd 4.2), respectively. A total of 15 (71%) of diabetic patients recovered a full range of movement as opposed to 19 (90%) in the non-diabetics. There was significant improvement (p < 0.01) in the modified Constant scores following arthroscopic release for frozen shoulder in both groups. The results in diabetics were significantly worse than those in non-diabetics six months post-operatively (p < 0.01) with a tendency towards persistent limitation of movement two years after operation. These results may be used when counselling diabetic patients for the outcome after arthroscopic treatment of frozen shoulder.

Cite this article: Bone Joint J 2014;96-B:1355–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1105 - 1109
1 Aug 2006
Kandemir U Allaire RB Jolly JT Debski RE McMahon PJ

Our aim was to determine the most repeatable three-dimensional measurement of glenoid orientation and to compare it between shoulders with intact and torn rotator cuffs. Our null hypothesis was that glenoid orientation in the scapulae of shoulders with a full-thickness tear of the rotator cuff was the same as that in shoulders with an intact rotator cuff.

We studied 24 shoulders in cadavers, 12 with an intact rotator cuff and 12 with a full-thickness tear. Two different observers used a three-dimensional digitising system to measure glenoid orientation in the scapular plane (ie glenoid inclination) using six different techniques. Glenoid version was also measured. The overall precision of the measurements revealed an error of less than 0.6°.

Intraobserver reliability (correlation coefficients of 0.990 and 0.984 for each observer) and interobserver reliability (correlation coefficient of 0.985) were highest for measurement of glenoid inclination based on the angle obtained from a line connecting the superior and inferior points of the glenoid and that connecting the most superior point of the glenoid and the most superior point on the body of the scapula. There were no differences in glenoid inclination (p = 0.34) or glenoid version (p = 0.12) in scapulae from shoulders with an intact rotator cuff and those with a full-thickness tear. Abnormal glenoid orientation was not present in shoulders with a torn rotator cuff.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1525 - 1529
1 Nov 2014
Thangarajah T Alexander S Bayley I Lambert SM

We report our experience with glenohumeral arthrodesis as a salvage procedure for epilepsy-related recurrent shoulder instability. A total of six patients with epilepsy underwent shoulder fusion for recurrent instability and were followed up for a mean of 39 months (12 to 79). The mean age at the time of surgery was 31 years (22 to 38). Arthrodesis was performed after a mean of four previous stabilisation attempts (0 to 11) in all but one patient in whom the procedure was used as a primary treatment. All patients achieved bony union, with a mean time to fusion of 2.8 months (2 to 7). There were no cases of re-dislocation. One revision was undertaken for loosening of the metalwork, and then healed satisfactorily. An increase was noted in the mean subjective shoulder value, which improved from 37 (5 to 50) pre-operatively to 42 (20 to 70) post-operatively although it decreased in two patients. The mean Oxford shoulder instability score improved from 13 pre-operatively (7 to 21) to 24 post-operatively (13 to 36). In our series, glenohumeral arthrodesis eliminated recurrent instability and improved functional outcome. Fusion surgery should therefore be considered in this patient population. However, since the majority of patients are young and active, they should be comprehensively counselled pre-operatively given the functional deficit that results from the procedure.

Cite this article: Bone Joint J 2014;96-B:1525–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1197 - 1200
1 Sep 2007
Quraishi NA Johnston P Bayer J Crowe M Chakrabarti AJ

This study prospectively evaluated the outcome of manipulation under anaesthesia and hydrodilatation as treatments for adhesive capsulitis. A total of 36 patients (38 shoulders) were randomised to receive either method, with all patients being treated in stage II of the disease process.

The mean age of the patients was 55.2 years (44 to 70) and the mean duration of symptoms was 33.7 weeks (12 to 76). Eighteen shoulders (17 patients) underwent manipulation under anaesthesia and 20 (19 patients) had hydrodilatation. There were three insulin-dependent diabetics in each group. The mean visual analogue score in the manipulation under anaesthesia group was 5.7 (3 to 8.5; n = 18) before treatment, 4.7 (0 to 8.5; n = 16) at two months (paired t-test p = 0.02), and 2.7 (0 to 9; n = 16) at six months (paired t-test, p = 0.0006). The mean score in the hydrodilatation group was 6.1 (4 to 10; n = 20) before treatment, 2.4 (0 to 8; n = 18) at two months (paired t-test, p = 0.001), and 1.7 (0 to 7; n = 18) at six months (paired t-test, p = 0.0006). The visual analogue scores in the hydrodilatation group were significantly better than in the manipulation under anaesthesia group over the six-month follow-up period (p < 0.0001).

The mean Constant score in those manipulated was 36 (26 to 66) before treatment, 58.5 (24 to 90) at two months (paired t-test, p = 0.001) and 59.5 (23 to 85) at six months (paired t-test, p = 0.0006). In the hydrodilatation group it was 28.8 (18 to 55) before treatment, 57.4 (17 to 80) at two months (paired t-test, p = 0.0004) and 65.9 (28 to 92) at six months (paired t-test, p = 0.0005). The Constant scores in the hydrodilatation group were significantly better than in the manipulated group over the six-month period of follow-up (p = 0.02).

The range of movement improved in all patients over the six months, but was not significantly different between the groups. At the final follow-up, 94% of patients (17 of 18) were satisfied or very satisfied after hydrodilatation compared with 81% (13 of 16) of those receiving a manipulation.

Most of our patients were treated successfully, but those undergoing hydrodilatation did better than those who were manipulated.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1088 - 1092
1 Aug 2011
Lizaur A Sanz-Reig J Gonzalez-Parreño S

The purpose of this study was to review the long-term outcomes of a previously reported prospective series of 46 type III acromioclavicular dislocations. These were treated surgically with temporary fixation of the acromioclavicular joint with wires, repair of the acromioclavicular ligaments, and overlapped suture of the deltoid and trapezius muscles. Of the 46 patients, one had died, four could not be traced, and three declined to return for follow-up, leaving 38 patients in the study. There were 36 men and two women, with a mean age at follow-up of 57.3 years (41 to 71). The mean follow-up was 24.2 years (21 to 26).

Patients were evaluated using the Imatani and University of California, Los Angeles (UCLA) scoring systems. Their subjective status was assessed using the Disabilities of the Arm, Shoulder and Hand and Simple Shoulder Test questionnaires, and a visual analogue scale for patient satisfaction. The examination included radiographs of the shoulder.

At a follow-up of 21 years, the results were satisfactory in 35 (92.1%) patients and unsatisfactory in three (7.9%). In total, 35 patients (92.1%) reported no pain, one slight pain, and two moderate pain. All except two patients had a full range of shoulder movement compared with the opposite side. Unsatisfactory results were the result of early redisplacement in two patients, and osteoarthritis without redisplacement in one. According to the Imatani and UCLA scores, there was no difference between the operated shoulder and the opposite shoulder (p > 0.05). Given the same situation, 35 (92.1%) patients would opt for the same surgical treatment again.

Operative treatment of type III acromioclavicular joint injuries produces satisfactory long-term results.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 795 - 800
1 Jun 2008
Liu T Zhang X Li Z Zeng W Peng D Sun C

Nonunion of the humerus with bone loss and shortening due to osteomyelitis is rare but difficult to treat. We describe our experience with a callus distraction technique using a monolateral external fixator for the treatment of this condition.

Between October 1994 and January 2004, 11 patients were treated. There were seven males and four females, with a mean age of 14 years (10 to 17). The mean bone loss was 1.9 cm (1 to 2.7) and the mean length discrepancy in the upper limb was 5.6 cm (3.5 to 8.0).

The mean follow-up was for 106 months (54 to 166). The mean external fixation index was 34.8 days/cm (29.8 to 40.5). The mean lengthening was 9.5 cm (5.5 to 13.4). There were seven excellent results, three good and one poor. There were nine excellent functional results and two good.

The treatment of humeral nonunion with bone loss and shortening due to osteomyelitis by callus distraction is a safe and effective means of improving function and cosmesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 504 - 510
1 Apr 2009
Henkus HE de Witte PB Nelissen RGHH Brand R van Arkel ERA

In a prospective randomised study we compared the results of arthroscopic subacromial bursectomy alone with debridement of the subacromial bursa followed by acromioplasty. A total of 57 patients with a mean age of 47 years (31 to 60) suffering from primary subacromial impingement without a rupture of the rotator cuff who had failed previous conservative treatment were entered into the trial. The type of acromion was classified according to Bigliani. Patients were assessed at follow-up using the Constant score, the simple shoulder test and visual analogue scores for pain and functional impairment. One patient was lost to follow-up.

At a mean follow-up of 2.5 years (1 to 5) both bursectomy and acromioplasty gave good clinical results. No statistically significant differences were found between the two treatments. The type of acromion and severity of symptoms had a greater influence on the clinical outcome than the type of treatment. As a result, we believe that primary subacromial impingement syndrome is largely an intrinsic degenerative condition rather than an extrinsic mechanical disorder.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 620 - 626
1 May 2007
Nath RK Paizi M

Residual muscle weakness in obstetric brachial plexus palsy results in soft-tissue contractures which limit the functional range of movement and lead to progressive glenoid dysplasia and joint instability. We describe the results of surgical treatment in 98 patients (mean age 2.5 years, 0.5 to 9.0) for the correction of active abduction of the shoulder. The patients underwent transfer of the latissimus dorsi and teres major muscles, release of contractures of subscapularis pectoralis major and minor, and axillary nerve decompression and neurolysis (the modified Quad procedure). The transferred muscles were sutured to the teres minor muscle, not to a point of bony insertion. The mean pre-operative active abduction was 45° (20° to 90°). At a mean follow-up of 4.8 years (2.0 to 8.7), the mean active abduction was 162° (100° to 180°) while 77 (78.6%) of the patients had active abduction of 160° or more. No decline in abduction was noted among the 29 patients (29.6%) followed up for six years or more. This procedure involving release of the contracted internal rotators of the shoulder combined with decompression and neurolysis of the axillary nerve greatly improves active abduction in young patients with muscle imbalance secondary to obstetric brachial plexus palsy.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 562 - 575
1 May 2006
Boileau P Sinnerton RJ Chuinard C Walch G


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 936 - 942
1 Jul 2014
Middleton C Uri O Phillips S Barmpagiannis K Higgs D Falworth M Bayley I Lambert S

Inherent disadvantages of reverse shoulder arthroplasty designs based on the Grammont concept have raised a renewed interest in less-medialised designs and techniques. The aim of this study was to evaluate the outcome of reverse shoulder arthroplasty (RSA) with the fully-constrained, less-medialised, Bayley–Walker prosthesis performed for the treatment of rotator-cuff-deficient shoulders with glenohumeral arthritis. A total of 97 arthroplasties in 92 patients (53 women and 44 men, mean age 67 years (standard deviation (sd) 10, (49 to 85)) were retrospectively reviewed at a mean follow-up of 50 months ((sd 25) (24 to 96)). The mean Oxford shoulder score and subjective shoulder value improved from 47 (sd 9) and 24 points (sd 18) respectively before surgery to 28 (sd 11) and 61 (sd 24) points after surgery (p <  0.001). The mean pain at rest decreased from 5.3 (sd 2.8) to 1.5 (sd 2.3) (p < 0.001). The mean active forward elevation and external rotation increased from 42°(sd 30) and 9° (sd 15) respectively pre-operatively to 78° (sd 39) and 24° (sd 17) post-operatively (p < 0.001). A total of 20 patients required further surgery for complications; 13 required revision of components. No patient developed scapular notching.

The Bayley–Walker prosthesis provides reliable pain relief and reasonable functional improvement for patients with symptomatic cuff-deficient shoulders. Compared with other designs of RSA, it offers a modest improvement in forward elevation, but restores external rotation to some extent and prevents scapular notching. A longer follow-up is required to assess the survival of the prosthesis and the clinical performance over time.

Cite this article: Bone Joint J 2014;96-B:936–42.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 71 - 76
1 Jan 2010
Diklic ID Ganic ZD Blagojevic ZD Nho SJ Romeo AA

The treatment of a chronic posterior dislocation of the shoulder is often determined by the size of the associated impression fracture of the humeral head. Our hypothesis was that patients with a chronic unreduced posterior dislocation of the shoulder and a defect in the humeral head involving between 25% to 50% of the articular surface, would do better if reconstructed with an allograft from the femoral head rather than treated by a non-anatomical reconstruction. We reviewed ten men and three women with a mean age of 42 years (36 to 51) at a mean follow-up of 54 months (41 to 64) who had this procedure. At follow-up, nine had no pain or restriction of activities of daily living. Their mean Constant-Murley shoulder score was 86.8 (43 to 98). No patient had symptoms of instability of the shoulder.

Reconstruction of the defect in the humeral head with an allograft provides good pain relief, stability and function for patients with a locked, chronic posterior dislocation where the defect involves between 25% and 50% of the circumference of the articular surface.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 499 - 503
1 Apr 2009
Kircher J Patzer T Magosch P Lichtenberg S Habermeyer P

We describe the outcome at a mean follow-up of 8.75 years (7.6 to 9.8) of seven patients who had undergone osteochondral autologous transplantation for full-thickness cartilage defects of the shoulder between 1998 and 2000. These patients have been described previously at a mean of 32.6 months when eight were included. One patient has been lost to follow-up. The outcome was assessed by the Constant shoulder score and the Lysholm knee score to assess any donor-site morbidity. Standard radiographs and MR scores were obtained and compared with the pre-operative findings and the results from the previous review.

No patient required any further surgery on the shoulder. The mean Constant score improved significantly until the final follow-up (p = 0.018). The Lysholm score remained excellent throughout. There was a significant progression of osteoarthritic changes from the initial surgery to the first and final follow-up but this did not appear to be related to the size of the defect, the number of cylinders required or the Constant score (p = 0.016). MRI showed that all except one patient had a congruent joint surface at the defect with full bony integration of all osteochondral cylinders.

The results have remained satisfactory over a longer period with very good objective and subjective findings.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 649 - 654
1 May 2009
Nath RK Liu X

Whereas a general trend in the management of obstetric brachial plexus injuries has been nerve reconstruction in patients without spontaneous recovery of biceps function by three to six months of age, many recent studies suggest this may be unnecessary. In this study, the severity of glenohumeral dysplasia and shoulder function and strength in two groups of matched patients with a C5-6 lesion at a mean age of seven years (2.7 to 13.3) were investigated. One group (23 patients) underwent nerve reconstruction and secondary operations, and the other (52 patients) underwent only secondary operations for similar initial clinical presentations. In the patients with nerve reconstruction shoulder function did not improve and they developed more severe shoulder deformities (posterior subluxation, glenoid version and scapular elevation) and required a mean of 2.4 times as many operations as patients without nerve reconstruction.

This study suggests that less invasive management, addressing the muscle and bone complications, is a more effective approach. Nerve reconstruction should be reserved for those less common cases where the C5 and C6 nerve roots will not recover.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1495 - 1498
1 Nov 2008
Shen J Tong P Qu H

This randomised study compared outcomes in patients with displaced fractures of the clavicle treated by open reduction and fixation by a reconstruction plate which was placed either superiorly or three-dimensionally. Between 2003 and 2006, 133 consecutive patients with a mean age of 44.2 years (18 to 60) with displaced midshaft fractures of the clavicle were allocated randomly to a three-dimensional (3D) (67 patients) or superior group (66). Outcome measures included the peri-operative outcome index, delayed union, revision surgery and symptoms beyond 16 weeks. CT was used to reconstruct an image of each affected clavicle and Photoshop 7.0 software employed to calculate the percentage of the clavicular cortical area in the sagittal plane. The patients were reviewed clinically and radiographically at four and 12 months after the operation. The superior plate group had a higher rate of delayed union and had more symptomatic patients than the 3D group (p < 0.05). The percentage comparisons of cortical bone area showed that cortical bone in the superior distal segment is thicker than in the inferior segment, it is also thicker in the anterior mid-section than in the posterior (p < 0.05).

If fixation of midshaft fractures of the clavicle with a plate is indicated, a 3D reconstruction plate is better than one placed superiorly, because it is consistent with the stress distribution and shape of the clavicle.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1432 - 1438
1 Oct 2013
Hultgren T Jönsson K Pettersson H Hammarberg H

We evaluated results at one year after surgical correction of internal rotation deformities in the shoulders of 270 patients with obstetric brachial plexus palsy. The mean age at surgery was 6.2 years (0.6 to 35). Two techniques were used: open subscapularis elongation and latissimus dorsi to infraspinatus transfer. In addition, open relocation was performed or attempted in all patients with subluxed or dislocated joints. A mixed effects model approach was used to evaluate the effects of surgery on internal and external rotation, abduction, flexion and Mallet score. Independent factors included operative status (pre- or post-operative), gender, age, the condition of the joint, and whether or not transfer was performed. The overall mean improvement in external rotation following surgery was 84.6° (95% confidence interval (CI) 80.2 to 89.1) and the mean Mallet score improved by 4.0 (95% CI 3.7 to 4.2). There was a mean decrease in internal rotation of between 27.6° and 34.4° in the relocated joint groups and 8.6° (95% CI 5.2 to 12.0) in the normal joint group. Abduction and flexion were unchanged following surgery. Adding a latissimus dorsi transfer did not result in greater improvement in the mean external rotation compared with elongation of the subscapularis alone.

Cite this article: Bone Joint J 2013;95-B:1432–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 977 - 982
1 Jul 2009
Terrier A Merlini F Pioletti DP Farron A

Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movement and joint stability were achieved by EMG-controlled activation of the muscles. A non-constant wear factor was considered. Simulated activities of daily living were estimated from in vivo recorded data.

After one year of use, the volumetric wear was 8.4 mm3 for the anatomical prosthesis, but 44.6 mm3 for the reversed version. For the anatomical prosthesis the predictions for contact pressure and wear were consistent with biomechanical and clinical data. The abrasive wear of the polyethylene in reversed prostheses should not be underestimated, and further analysis, both experimental and clinical, is required.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 201 - 205
1 Feb 2009
Hanusch BC Goodchild L Finn P Rangan A

The aim of this study was to determine the functional outcome and rate of re-tears following mini-open repair of symptomatic large and massive tears of the rotator cuff using a two-row technique.

The 24 patients included in the study were assessed prospectively before and at a mean of 27 months (18 to 53) after surgery using the Constant and the Oxford Shoulder scores. Ultrasound examination was carried out at follow-up to determine the integrity of the repair. Patient satisfaction was assessed using a simple questionnaire.

The mean Constant score improved significantly from 36 before to 68 after operation (p < 0.0001) and the mean Oxford Shoulder score from 39 to 20 (p < 0.0001). Four of the 24 patients (17%) had a re-tear diagnosed by ultrasound. A total of 21 patients (87.5%) were satisfied with the outcome of their surgery. The repair remained intact in 20 patients (83%). However, the small number of re-tears (four patients) in the study did not allow sufficient analysis to show a difference in outcome in relation to the integrity of the repair.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1184 - 1187
1 Sep 2007
Rispoli DM Sperling JW Athwal GS Schleck CD Cofield RH

We have examined the relief from pain and the functional outcome in 18 patients who underwent resection arthroplasty of the shoulder as a salvage operation between 1988 and 2002. The indications included failed shoulder replacement in 17, with infection in 13, and chronic septic arthritis in one. The mean follow-up was 8.3 years (2.5 to 16.6). Two intra-operative fractures of the humerus occurred, both of which healed.

The level of pain was significantly decreased (t-test, p < 0.001) but five patients continued to have moderate to severe pain. The mean active elevation was 70° (0° to 150°) postoperatively and represented an improvement from 39° (0° to 140°) (t-test, p = 0.003), but internal and external rotation were hardly changed. The mean number of positive answers on the 12-question Simple Shoulder Test was 3.1 (0 to 12) but the shoulder was generally comfortable when the arm was positioned at rest by the side. The mean post-operative American Shoulder and Elbow Surgeon’s score was 36 (8 to 73).

Despite applying this procedure principally to failed shoulder replacements, the results were similar to those reported in the literature for patients after severe fracture-dislocation. Reduction of pain is possible in one half to two-thirds of patients. The outcome of this operation in providing relief from pain cannot be guaranteed, but the shoulder is usually comfortable at rest, albeit with profound functional limitations.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1666 - 1669
1 Dec 2012
Gulotta LV Choi D Marinello P Wright T Cordasco FA Craig EV Warren RF

Reverse total shoulder replacement (RTSR) depends on adequate deltoid function for a successful outcome. However, the anterior deltoid and/or axillary nerve may be damaged due to prior procedures or injury. The purpose of this study was to determine the compensatory muscle forces required for scapular plane elevation following RTSR when the anterior deltoid is deficient. The soft tissues were removed from six cadaver shoulders, except for tendon attachments. After implantation of the RTSR, the shoulders were mounted on a custom-made shoulder simulator to determine the mean force in each muscle required to achieve 30° and 60° of scapular plane elevation. Two conditions were tested: 1) Control with an absent supraspinatus and infraspinatus; and 2) Control with anterior deltoid deficiency. Anterior deltoid deficiency resulted in a mean increase of 195% in subscapularis force at 30° when compared with the control (p = 0.02). At 60°, the subscapularis force increased a mean of 82% (p < 0.001) and the middle deltoid force increased a mean of 26% (p = 0.04).

Scapular plane elevation may still be possible following an RTSR in the setting of anterior deltoid deficiency. When the anterior deltoid is deficient, there is a compensatory increase in the force required by the subscapularis and middle deltoid. Attempts to preserve the subscapularis, if present, might maximise post-operative function.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 523 - 529
1 Apr 2013
Henseler JF Nagels J van der Zwaal P Nelissen RGHH

Surgical repair of posterosuperior rotator cuff tears has a poorer outcome and a higher rate of failure compared with repairs of supraspinatus tears. In this prospective cohort study 28 consecutive patients with an irreparable posterosuperior rotator cuff tear after failed conservative or surgical treatment underwent teres major tendon transfer. Their mean age was 60 years (48 to 71) and the mean follow-up was 25 months (12 to 80). The mean active abduction improved from 79° (0° to 150°) pre-operatively to 105° (20° to 180°) post-operatively (p = 0.011). The mean active external rotation in 90° abduction improved from 25° (0° to 70°) pre-operatively to 55° (0° to 90°) post-operatively (p < 0.001). The mean Constant score improved from 43 (18 to 78) pre-operatively to 65 (30 to 86) post-operatively (p < 0.001). The median post-operative VAS (0 to 100) for pain decreased from 63 (0 to 96) pre-operatively to 5 (0 to 56) post-operatively (p < 0.001).

In conclusion, teres major transfer effectively restores function and relieves pain in patients with irreparable posterosuperior rotator cuff tears and leads to an overall clinical improvement in a relatively young and active patient group with limited treatment options.

Cite this article: Bone Joint J 2013;95-B:523–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1494 - 1498
1 Nov 2012
Philippon MJ Pennock A Gaskill TR

Femoroacetabular impingement causes groin pain and decreased athletic performance in active adults. This bony conflict may result in femoroacetabular subluxation if of sufficient magnitude.

The ligamentum teres has recently been reported to be capable of withstanding tensile loads similar to that of the anterior cruciate ligament, and patents with early subluxation of the hip may become dependent on the secondary restraint that is potentially provided by the ligamentum teres. Rupture of the ligamentum may thus cause symptomatic hip instability during athletic activities.

An arthroscopic reconstruction of the ligamentum teres using iliotibial band autograft was performed in an attempt to restore this static stabiliser in a series of four such patients. Early clinical results have been promising. The indications, technique and early outcomes of this procedure are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1534 - 1539
1 Nov 2012
Karataglis D Papadopoulos P Boutsiadis A Fotiadou A Ditsios K Hatzokos I Christodoulou A

This study evaluates the position of the long head of biceps tendon using ultrasound following simple tenotomy, in patients with arthroscopically repaired rotator cuff tears.

In total, 52 patients with a mean age of 60.7 years (45 to 75) underwent arthroscopic repair of the rotator cuff and simple tenotomy of the long head of biceps tendon. At two years post-operatively, ultrasound revealed that the tendon was inside the bicipital groove in 43 patients (82.7%) and outside in nine (17.3%); in six of these it was lying just outside the groove and in the remaining three (5.8%) it was in a remote position with a positive Popeye Sign. A dynamic ultrasound scan revealed that the tenotomised tendons had adhered to the surrounding tissues (autotenodesis).The initial condition of the tendon influenced its final position (p < 0.0005). The presence of a Popeye sign was statistically influenced by the pre-operative co-existence of supraspinatus and subscapularis tears (p < 0.0001).

It appears that the natural history of the tenotomised long head of biceps tendon is to tenodese itself inside or just outside the bicipital groove, while its pre-operative condition and coexistent subscapularis tears play a significant role in the occurrence of a Popeye sign.