Advertisement for orthosearch.org.uk
Results 1 - 100 of 166
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 112 - 115
1 Nov 2012
Su EP

Fixed flexion deformities are common in osteoarthritic knees that are indicated for total knee arthroplasty. The lack of full extension at the knee results in a greater force of quadriceps contracture and energy expenditure. It also results in slower walking velocity and abnormal gait mechanics, overloading the contralateral limb. Residual flexion contractures after TKA have been associated with poorer functional scores and outcomes. Although some flexion contractures may resolve with time after surgery, a substantial percentage will become permanent. Therefore, it is essential to correct fixed flexion deformities at the time of TKA, and be vigilant in the post-operative course to maintain the correction. Surgical techniques to address pre-operative flexion contractures include: adequate bone resection, ligament releases, removal of posterior osteophytes, and posterior capsular releases. Post-operatively, extension can be maintained with focused physiotherapy, a specially modified continuous passive motion machine, a contralateral heel lift, and splinting


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 248 - 254
1 Feb 2006
Ma FYP Selber P Nattrass GR Harvey AR Wolfe R Graham HK

Between July 2000 and April 2004, 19 patients with bilateral spastic cerebral palsy who required an assistive device to walk had combined lengthening-transfer of the medial hamstrings as part of multilevel surgery. A standardised physical examination, measurement of the Functional Mobility Scale score and video or instrumented gait analysis were performed pre- and post-operatively. Static parameters (popliteal angle, flexion deformity of the knee) and sagittal knee kinematic parameters (knee flexion at initial contact, minimum knee flexion during stance, mean knee flexion during stance) were recorded. The mean length of follow-up was 25 months (14 to 45). Statistically significant improvements in static and dynamic outcome parameters were found, corresponding to improvements in gait and functional mobility as determined by the Functional Mobility Scale. Mild hyperextension of the knee during gait developed in two patients and was controlled by adjustment of their ankle-foot orthosis. Residual flexion deformity > 10° occurred in both knees of one patient and was treated by anterior distal femoral physeal stapling. Two children also showed an improvement of one level in the Gross Motor Function Classification System


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 934 - 936
1 Jul 2005
Aderinto J Brenkel IJ Chan P

We investigated fixed flexion deformity (FFD) after total knee replacement (TKR). Data relating to 369 cruciate-retaining unilateral TKRs performed at a single institution were collected prospectively. Fixed flexion was measured pre-operatively and at one week, six months, 18 months, three years and five years after surgery. Using binary logistic regression, pre-operative FFD was a predictor of post-operative FFD > 10° at one week (p = 0.006) and six months (p = 0.003) following surgery. Gender was a predictor at one week (p = 0.0073) with 24% of women showing a FFD > 10° compared with 37% of men. We have shown that a gradual improvement in knee extension can be expected up to three years after surgery in knees with FFD. By this time residual FFD is mild or absent in the majority of patients, including those who had a severe pre-operative FFD


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 395 - 399
1 May 1987
Tew M Forster I

One of the objectives of knee replacement is to correct flexion deformity, the frequent consequence of rheumatoid arthritis and osteoarthritis. A review of 697 primary and revision replacements carried out between 1969 and 1985 and followed up from 1 to 16 years found that such deformity was present in 61% of knees before the primary operation. Replacement reduced this to 17% and the improvement was usually maintained. The deformity was present in only 21% of the replacements which required revision and the second operation reduced this to 8%. Flexion contractures affected rheumatoid knees more often and more seriously than osteoarthritic knees, but arthroplasty was more successful in correcting the deformity in the former. All of the 11 types of prosthesis used achieved some degree of correction, but the Walldius hinge and the variants of the Freeman condylar design were the most successful. Surprisingly, the best outcome, in terms of pain and reduced need for revision, was found in the rheumatoid knees most seriously deformed before operation, but this association was absent in the osteoarthritic knees. Postoperative deformity in knees without pain or extreme weakness did not appear to influence the patients' ability to walk or to use stairs or a chair, as measured by unexacting tests in the clinic


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 471 - 473
1 May 1994
Aspden R Porter R

We report the case of a child with cerebral palsy and spastic diplegia treated for bilateral fixed flexion of the knee by bilateral hamstring lengthening. An attempt to straighten the legs from 90 degrees to 20 degrees flexion damaged the sciatic nerve. There are no objective means of estimating how much deformity can be reduced safely. We present a method of calculating the extra strain in the sciatic nerve produced by reducing a flexion deformity. The result, combined with clinical judgement, provides guidelines for safe corrective surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 2 | Pages 180 - 183
1 May 1980
Waugh W Newton G Tew M

In a consecutive series of 87 operations for knee replacement prospective observations were made of the pattern of articular destruction in the form of a triangle of erosion or osteophyte formation, which is seen on the medial femoral condyle, sometimes with an associated strip on the lateral femoral condyle. These areas represent the surfaces which are normally in contact with the anterior horns of the menisci when the knee is fully extended. The lesions in question were found only in association with a flexion contracture in 84 out of the 87 cases.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1230 - 1237
1 Oct 2019
Kayani B Konan S Horriat S Ibrahim MS Haddad FS

Aims. The aim of this study was to assess the effect of posterior cruciate ligament (PCL) resection on flexion-extension gaps, mediolateral soft-tissue laxity, fixed flexion deformity (FFD), and limb alignment during posterior-stabilized (PS) total knee arthroplasty (TKA). Patients and Methods. This prospective study included 110 patients with symptomatic osteoarthritis of the knee undergoing primary robot-assisted PS TKA. All operations were performed by a single surgeon using a standard medial parapatellar approach. Optical motion capture technology with fixed femoral and tibial registration pins was used to assess gaps before and after PCL resection in extension and 90° knee flexion. Measurements were made after excision of the anterior cruciate ligament and prior to bone resection. There were 54 men (49.1%) and 56 women (50.9%) with a mean age of 68 years (. sd. 6.2) at the time of surgery. The mean preoperative hip-knee-ankle deformity was 4.1° varus (. sd. 3.4). Results. PCL resection increased the mean flexion gap significantly more than the extension gap in the medial (2.4 mm (. sd. 1.5) vs 1.3 mm (. sd. 1.0); p < 0.001) and lateral (3.3 mm (. sd. 1.6) vs 1.2 mm (. sd. 0.9); p < 0.01) compartments. The mean gap differences after PCL resection created significant mediolateral laxity in flexion (gap difference: 1.1 mm (. sd. 2.5); p < 0.001) but not in extension (gap difference: 0.1 mm (. sd. 2.1); p = 0.51). PCL resection significantly improved the mean FFD (6.3° (. sd. 4.4) preoperatively vs 3.1° (. sd. 1.5) postoperatively; p < 0.001). There was a strong positive correlation between the preoperative FFD and change in FFD following PCL resection (Pearson’s correlation coefficient = 0.81; p < 0.001). PCL resection did not significantly affect limb alignment (mean change in alignment: 0.2° valgus (. sd. 1.2); p = 0.60). Conclusion. PCL resection creates flexion-extension mismatch by increasing the flexion gap more than the extension gap. The increase in the lateral flexion gap is greater than the increase in the medial flexion gap, which creates mediolateral laxity in flexion. Improvements in FFD following PCL resection are dependent on the degree of deformity before PCL resection. Cite this article: Bone Joint J 2019;101-B:1230–1237


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 858 - 860
1 Jun 2005
Lahoti O Bell MJ

We present the long-term results of pectoralis major transfer to restore elbow flexion in seven patients (ten procedures). The early results in all the patients were encouraging but with longer follow-up a gradual and progressive flexion deformity was observed with a decrease in the arc of flexion in eight elbows, reaching ≥ 90° in all cases. The results of pectoralis major transfer deteriorate with time due to the development of a recalcitrant flexion deformity of the elbow. With bilateral involvement we now recommend that the procedure be undertaken on one side only to allow the hand to reach the mouth for feeding, while the opposite side remains in extension for perineal toilet


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 442 - 448
1 Apr 2020
Kayani B Konan S Ahmed SS Chang JS Ayuob A Haddad FS

Aims. The objectives of this study were to assess the effect of anterior cruciate ligament (ACL) resection on flexion-extension gaps, mediolateral soft tissue laxity, maximum knee extension, and limb alignment during primary total knee arthroplasty (TKA). Methods. This prospective study included 140 patients with symptomatic knee osteoarthritis undergoing primary robotic-arm assisted TKA. All operative procedures were performed by a single surgeon using a standard medial parapatellar approach. Optical motion capture technology with fixed femoral and tibial registration pins was used to assess study outcomes pre- and post-ACL resection with knee extension and 90° knee flexion. This study included 76 males (54.3%) and 64 females (45.7%) with a mean age of 64.1 years (SD 6.8) at time of surgery. Mean preoperative hip-knee-ankle deformity was 6.1° varus (SD 4.6° varus). Results. ACL resection increased the mean extension gap significantly more than the flexion gap in the medial (mean 1.2 mm (SD 1.0) versus mean 0.2 mm (SD 0.7) respectively; p < 0.001) and lateral (mean 1.1 mm (SD 0.9) versus mean 0.2 mm (SD 0.6) respectively; p < 0.001) compartments. The mean gap differences following ACL resection did not create any significant mediolateral soft tissue laxity in extension (gap difference: mean 0.1 mm (SD 2.4); p = 0.89) or flexion (gap difference: mean 0.2 mm (SD 3.1); p = 0.40). ACL resection did not significantly affect maximum knee extension (change in maximum knee extension = mean 0.2° (SD 0.7°); p = 0.23) or fixed flexion deformity (mean 4.2° (SD 3.2°) pre-ACL release versus mean 3.9° (SD 3.7°) post-ACL release; p = 0.61). ACL resection did not significantly affect overall limb alignment (change in alignment = mean 0.2° valgus (SD 1.0° valgus; p = 0.11). Conclusion. ACL resection creates flexion-extension mismatch by increasing the extension gap more than the flexion gap. However, gap differences following ACL resection do not create any mediolateral soft tissue laxity in extension or flexion. ACL resection does not affect maximum knee extension or overall limb alignment. Cite this article: Bone Joint J 2020;102-B(4):442–448


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 299 - 302
1 Mar 1996
Frawley PA Broughton NS Menelaus MB

We reviewed the results of anterior hip release for fixed flexion deformity in 57 hips in 38 children with spina bifida at an average follow-up of 8.9 years (2 to 22). The indication for this operation was a fixed flexion deformity of more than 30° which interfered with function. In 43 hips there was a good outcome in that the fixed flexion deformity remained less than 30° at follow-up. Four hips had a good initial result but deteriorated after an average of five years, and ten had a poor outcome with deformity of over 30°. Six hips required a repeated anterior hip release and two of these were successful. The success of anterior hip release could not be related to the neurological level or the age at operation. Successful surgery correlated with the walking ability of the child at the latest follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 2 | Pages 238 - 251
1 May 1969
Menelaus MB

1. Paralytic dislocation of the hip in spina bifida generally requires reduction and iliopsoas transfer. The muscle transfer ensures that the hip remains reduced, lessens the need for calipers and prevents progressive flexion deformity. In addition, varus and rotation osteotomy of the femur and innominate osteotomy are sometimes required. Varus and rotation osteotomy alone is indicated if the psoas is not strong enough for transfer. The age for reduction of dislocated hips and muscle transfer has been reduced to eight months as experience and confidence has been gained. 2. Flexion deformity is best prevented by early iliopsoas transfer. An anterior release operation is occasionally indicated when there is flexion deformity and a weak psoas muscle. This procedure, alone or supplemented by extension osteotomy, may be necessary to correct severe flexion deformity in children seen late. 3. Lateral rotation deformity of the hip may be caused by unbalanced iliopsoas action or the unbalanced action, or contracture, of the short lateral rotator muscles. If the deformity is sufficient to make the gait bizarre, or if it is difficult to fit a caliper, then soft-tissue operations as described are of value. 4. Abduction deformity can be corrected by division of the unopposed or contracted abductors


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims

Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice.

Methods

This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m2 (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims

Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up.

Methods

This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36).


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims

As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach.

Methods

A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 793 - 798
1 Jun 2016
Kohl S Evangelopoulos DS Schär MO Bieri K Müller T Ahmad SS

Aims. The purpose of this study was to report the experience of dynamic intraligamentary stabilisation (DIS) using the Ligamys device for the treatment of acute ruptures of the anterior cruciate ligament (ACL). Patients and Methods. Between March 2011 and April 2012, 50 patients (34 men and 16 women) with an acute rupture of the ACL underwent primary repair using this device. The mean age of the patients was 30 years (18 to 50). Patients were evaluated for laxity, stability, range of movement (ROM), Tegner, Lysholm, International Knee Documentation Committee (IKDC) and visual analogue scale (VAS) scores over a follow-up period of two years. Results. At final follow-up, anteroposterior translation differed from the normal knee by a mean of 0.96 mm (-2 mm to 6 mm). Median (interquartile range) IKDC, Tegner, Lysholm and VAS scores were 98 (95 to 100), 6 (5 to 7), 100 (98 to 100) and 10 (9 to 10), respectively. Pre-injury Tegner activity levels were reached one year post-operatively. A total of nine patients (18%) required a secondary intervention; five developed instability, of whom four underwent secondary hamstring reconstructive surgery, and five required arthroscopic treatment for intra-articular impingement due to scar tissue which caused a fixed flexion deformity. In addition, 30 patients (60%) required removal of the tibial screw. Conclusion. While there was a high rate of secondary interventions, 45 patients (90%) retained their repaired ACL two years post-operatively, with good clinical scores and stability of the knee. Take home message: Dynamic intraligamentary stabilisation presents a promising treatment option for acute ACL ruptures, eliminating the need for ACL reconstruction. Cite this article: Bone Joint J 2016;98-B:793–8


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1301 - 1305
1 Nov 2024
Prajapati A Thakur RPS Gulia A Puri A

Aims

Reconstruction after osteoarticular resection of the proximal ulna for tumours is technically difficult and little has been written about the options that are available. We report a series of four patients who underwent radial neck to humeral trochlea transposition arthroplasty following proximal ulnar osteoarticular resection.

Methods

Between July 2020 and July 2022, four patients with primary bone tumours of the ulna underwent radial neck to humeral trochlea transposition arthroplasty. Their mean age was 28 years (12 to 41). The functional outcome was assessed using the range of motion (ROM) of the elbow, rotation of the forearm and stability of the elbow, the Musculoskeletal Tumor Society score (MSTS), and the nine-item abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH-9) score.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 568 - 574
1 May 2023
Kobayashi H Ito N Nakai Y Katoh H Okajima K Zhang L Tsuda Y Tanaka S

Aims

The aim of this study was to report the patterns of symptoms and insufficiency fractures in patients with tumour-induced osteomalacia (TIO) to allow the early diagnosis of this rare condition.

Methods

The study included 33 patients with TIO who were treated between January 2000 and June 2022. The causative tumour was detected in all patients. We investigated the symptoms and evaluated the radiological patterns of insufficiency fractures of the rib, spine, and limbs.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 347 - 350
1 Apr 2003
Phillips NJ Ali A Stanley D

Between 1990 and 1996 we performed 20 consecutive ulnohumeral arthroplasties for primary osteoarthritis of the elbow. The outcome was assessed using the Disabilities of Arm, Shoulder and Hand Score (DASH) and the Mayo Elbow Performance Score (MEPS) at a mean follow-up of 75 months (58 to 132). There were excellent or good results in 17 elbows (85%) using the DASH score and in 13 (65%) with the MEPS (correlation coefficient 0.79). The mean fixed flexion deformity had improved by 10° and the range of flexion by a mean of 20°. In 16 elbows (80%) the benefits of surgery had been maintained, and of 16 patients working at the time of operation, 12 (75%) had returned to the same job. There was no correlation between radiological recurrence of degenerative changes and the amount of fixed flexion deformity, the flexion arc, or the elbow scores


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 696 - 701
1 Jun 2023
Kurisunkal V Morris G Kaneuchi Y Bleibleh S James S Botchu R Jeys L Parry MC

Aims

Intra-articular (IA) tumours around the knee are treated with extra-articular (EA) resection, which is associated with poor functional outcomes. We aim to evaluate the accuracy of MRI in predicting IA involvement around the knee.

Methods

We identified 63 cases of high-grade sarcomas in or around the distal femur that underwent an EA resection from a prospectively maintained database (January 1996 to April 2020). Suspicion of IA disease was noted in 52 cases, six had IA pathological fracture, two had an effusion, two had prior surgical intervention (curettage/IA intervention), and one had an osseous metastasis in the proximal tibia. To ascertain validity, two musculoskeletal radiologists (R1, R2) reviewed the preoperative imaging (MRI) of 63 consecutive cases on two occasions six weeks apart. The radiological criteria for IA disease comprised evidence of tumour extension within the suprapatellar pouch, intercondylar notch, extension along medial/lateral retinaculum, and presence of IA fracture. The radiological predictions were then confirmed with the final histopathology of the resected specimens.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 888 - 894
1 Aug 2023
Murray J Jeyapalan R Davies M Sheehan C Petrie M Harrison T

Aims

Total femoral arthroplasty (TFA) is a rare procedure used in cases of significant femoral bone loss, commonly from cancer, infection, and trauma. Low patient numbers have resulted in limited published work on long-term outcomes, and even less regarding TFA undertaken for non-oncological indications. The aim of this study was to evaluate the long-term clinical outcomes of all TFAs in our unit.

Methods

Data were collected retrospectively from a large tertiary referral revision arthroplasty unit’s database. Inclusion criteria included all patients who underwent TFA in our unit. Preoperative demographics, operative factors, and short- and long-term outcomes were collected for analysis. Outcome was defined using the Musculoskeletal Infection Society (MSIS) outcome reporting tool.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 1017 - 1022
1 Jul 2010
Kelley SP Bache CE Graham HK Donnan LT

We report the outcome of 28 patients with spina bifida who between 1989 and 2006 underwent 43 lower extremity deformity corrections using the Ilizarov technique. The indications were a flexion deformity of the knee in 13 limbs, tibial rotational deformity in 11 and foot deformity in 19. The mean age at operation was 12.3 years (5.2 to 20.6). Patients had a mean of 1.6 previous operations (0 to 5) on the affected limb. The mean duration of treatment with a frame was 9.4 weeks (3 to 26) and the mean follow-up was 4.4 years (1 to 9). There were 12 problems (27.9%), five obstacles (11.6%) and 13 complications (30.2%) in the 43 procedures. Further operations were needed in seven patients. Three knees had significant recurrence of deformity. Two tibiae required further surgery for recurrence. All feet were plantigrade and braceable. We conclude that the Ilizarov technique offers a refreshing approach to the complex lower-limb deformity in spina bifida


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 19 - 27
1 Jan 2024
Tang H Guo S Ma Z Wang S Zhou Y

Aims

The aim of this study was to evaluate the reliability and validity of a patient-specific algorithm which we developed for predicting changes in sagittal pelvic tilt after total hip arthroplasty (THA).

Methods

This retrospective study included 143 patients who underwent 171 THAs between April 2019 and October 2020 and had full-body lateral radiographs preoperatively and at one year postoperatively. We measured the pelvic incidence (PI), the sagittal vertical axis (SVA), pelvic tilt, sacral slope (SS), lumbar lordosis (LL), and thoracic kyphosis to classify patients into types A, B1, B2, B3, and C. The change of pelvic tilt was predicted according to the normal range of SVA (0 mm to 50 mm) for types A, B1, B2, and B3, and based on the absolute value of one-third of the PI-LL mismatch for type C patients. The reliability of the classification of the patients and the prediction of the change of pelvic tilt were assessed using kappa values and intraclass correlation coefficients (ICCs), respectively. Validity was assessed using the overall mean error and mean absolute error (MAE) for the prediction of the change of pelvic tilt.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 267 - 270
1 Mar 1994
Witt J McCullough C

We report the results of anterior soft-tissue release of the hip for fixed flexion deformity in 17 patients (31 hips) with juvenile chronic arthritis. The mean age at operation was 8 years 6 months. All the patients were reviewed at one and three years and 11 (21 hips) were available for review at five years. The results were good as regards early pain relief and improved mobility. At one year, the average fixed flexion deformity was reduced from 35 degrees to 9.5 degrees, and at three years it was 18 degrees. This degree of improvement was maintained in the hips followed for five years. At 5 to 12 years' follow-up (mean 6.7) seven patients (14 hips) have required no further surgery and have maintained an acceptable range of motion. We discuss the influence of surgery on radiographic changes and on femoral neck anteversion


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 35 - 46
1 Jan 2023
Mills K Wymenga AB Bénard MR Kaptein BL Defoort KC van Hellemondt GG Heesterbeek PJC

Aims

The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA).

Methods

A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 140 - 144
1 Jan 1996
Damsin J Ghanem I

We have used the Ilizarov technique for severe flexion deformity of the knee in 11 patients (13 knees) between 1986 and 1994 and have followed them up for an average of 4.1 years. The age of the patients at operation ranged from 1.7 to 18.8 years. The femoral and tibial components were connected by two anterior hinges, medial and lateral, and two posterior distraction rods. The deformity was corrected to a femorotibial lateral shaft angle of less than 20°. A permanent orthosis was applied after removal of the fixator. Fractures occurred in four patients and paralysis of the common peroneal nerve in another. There was a recurrence of the deformity in four patients. At the last review all patients were able to walk on their operated leg with or without an orthosis. We have found the Ilizarov method to be helpful in correcting severe fixed flexion deformity of the knee, with relatively few complications, but the basic principles of the method must be carefully followed


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1104 - 1109
1 Oct 2022
Hansjee S Giebaly DE Shaarani SR Haddad FS

We aim to explore the potential technologies for monitoring and assessment of patients undergoing arthroplasty by examining selected literature focusing on the technology currently available and reflecting on possible future development and application. The reviewed literature indicates a large variety of different hardware and software, widely available and used in a limited manner, to assess patients’ performance. There are extensive opportunities to enhance and integrate the systems which are already in existence to develop patient-specific pathways for rehabilitation.

Cite this article: Bone Joint J 2022;104-B(10):1104–1109.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 488 - 494
1 May 1993
Nene A Evans G Patrick J

We assessed the outcome after simultaneous multiple operations performed on 18 children with spastic diplegia, with emphasis on the changes in the physiological cost index (PCI) of walking. Fourteen patients had a measurable reduction at one year, but the more severely affected patients took up to two years to reach a new functional plateau. The level of the preoperative PCI allows prediction of the outcome of surgery in terms of reducing the effort of walking, or improving its appearance only. Intrapelvic intramuscular psoas tenotomy produced an improvement of hip flexion deformity in 15 of 17 patients without the loss of muscle power to initiate the swing phase. Fractional lengthening corrected hamstring tightness in 17 cases, and the mean popliteal angle was reduced from 63 degrees preoperatively to 30.2 degrees, with almost complete resolution of the fixed knee flexion deformity present in ten patients. Distal transfer of the rectus femoris, when it was shown to be contracting inappropriately, improved the knee flexion arc during walking from a mean of 28.3 degrees to 45.2 degrees


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 296 - 300
1 Mar 1999
Kim Y Cho S Kim J

Between June 1993 and December 1994, we performed total knee arthroplasty (TKA) on 27 knees in 24 patients with spontaneous bony ankylosis in severe flexion. The mean age at operation was 43.5 years (30 to 60). No patient had preoperative pain. Three were unable to walk and 21 could manage less than five blocks. The mean duration of the ankylosis was 18.7 years (13 to 25) and its mean position was 105° flexion (75 to 135). The preoperative Hospital for Special Surgery Knee Score of 60 points was improved to 87 at the final follow-up three to five years later. All knees were free from pain. The mean range of active flexion in 24 knees was 97° (78 to 115) and the mean arc of movement 91° (78 to 98). The mean fixed flexion deformity was 6° (0 to 25) and the extension lag 8° (0 to 25). Angular deformity was corrected to between 0° and 10° of valgus. Four patients were able to walk one block and 20 five to seven blocks. Thirteen knees (48%) showed some necrosis at the skin edge; one knee required arthrodesis and another resection arthroplasty. One had a recurrence of tuberculous infection requiring arthrodesis. One patient had a rupture of the quadriceps tendon. To date no prosthesis has required revision for loosening. Radiolucency of 1 mm or less about the tibial prosthesis was observed at follow-up in four of the 24 knees. Our results have shown that one-stage TKA and skeletal traction after operation can achieve correction of severe flexion deformity of the knee with marked improvement in the function and quality of life


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 649 - 654
1 May 2006
Gupta A Meswania J Pollock R Cannon SR Briggs TWR Taylor S Blunn G

We report our early experience with the use of a non-invasive distal femoral expandable endoprosthesis in seven skeletally immature patients with osteosarcoma of the distal femur. The patients had a mean age of 12.1 years (9 to 15) at the time of surgery. The prosthesis was lengthened at appropriate intervals in outpatient clinics, without anaesthesia, using the principle of electromagnetic induction. The patients were functionally evaluated using the Musculoskeletal Tumour Society scoring system. The mean follow-up was 20.2 months (14 to 30). The prostheses were lengthened by a mean of 25 mm (4.25 to 55) and maintained a mean knee flexion of 110° (100° to 120°). The mean Musculoskeletal Tumour Society score was 68% (11 to 29). Complications developed in two patients; one developed a flexion deformity of 25° at the knee joint, which was subsequently overcome and one died of disseminated disease. The early results from patients treated with this device have been encouraging. The implant avoids multiple surgical procedures, general anaesthesia and assists in maintaining leg-length equality


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims

The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection.

Methods

From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.


Aims

The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery.

Methods

A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model.


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 189 - 192
1 Feb 2022
Scott CEH Clement ND Davis ET Haddad FS


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 34 - 44
1 Jan 2022
Beckers L Dandois F Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims

Higher osteoblastic bone activity is expected in aseptic loosening and painful unicompartmental knee arthroplasty (UKA). However, insights into normal bone activity patterns after medial UKAs are lacking. The aim of this study was to identify the evolution in bone activity pattern in well-functioning medial mobile-bearing UKAs.

Methods

In total, 34 patients (13 female, 21 male; mean age 62 years (41 to 79); BMI 29.7 kg/m2 (23.6 to 42.1)) with 38 medial Oxford partial UKAs (20 left, 18 right; 19 cementless, 14 cemented, and five hybrid) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively, and at one and two years postoperatively. Changes in mean osteoblastic activity were investigated using a tracer localization scheme with volumes of interest (VOIs), reported by normalized mean tracer values. A SPECT/CT registration platform additionally explored cortical tracer evolution in zones of interest identified by previous experimental research.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 642 - 647
1 May 2012
Mullaji A Lingaraju AP Shetty GM

We retrospectively reviewed the records of 1150 computer-assisted total knee replacements and analysed the clinical and radiological outcomes of 45 knees that had arthritis with a pre-operative recurvatum deformity. The mean pre-operative hyperextension deformity of 11° (6° to 15°), as measured by navigation at the start of the operation, improved to a mean flexion deformity of 3.1° (0° to 7°) post-operatively. A total of 41 knees (91%) were managed using inserts ≤ 12.5 mm thick, and none had mediolateral laxity > 2 mm from a mechanical axis of 0° at the end of the surgery. At a mean follow-up of 26.4 months (13 to 48) there was significant improvement in the mean Knee Society, Oxford knee and Western Ontario and McMaster Universities Osteoarthritis Index scores compared with the pre-operative values. The mean knee flexion improved from 105° (80° to 125°) pre-operatively to 131° (120° to 145°), and none of the limbs had recurrent recurvatum. These early results show that total knee replacement using computer navigation and an algorithmic approach for arthritic knees with a recurvatum deformity can give excellent radiological and functional outcomes without recurrent deformity


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 507 - 514
1 Mar 2021
Chang JS Kayani B Wallace C Haddad FS

Aims

Total knee arthroplasty (TKA) using functional alignment aims to implant the components with minimal compromise of the soft-tissue envelope by restoring the plane and obliquity of the non-arthritic joint. The objective of this study was to determine the effect of TKA with functional alignment on mediolateral soft-tissue balance as assessed using intraoperative sensor-guided technology.

Methods

This prospective study included 30 consecutive patients undergoing robotic-assisted TKA using the Stryker PS Triathlon implant with functional alignment. Intraoperative soft-tissue balance was assessed using sensor-guided technology after definitive component implantation; soft-tissue balance was defined as intercompartmental pressure difference (ICPD) of < 15 psi. Medial and lateral compartment pressures were recorded at 10°, 45°, and 90° of knee flexion. This study included 18 females (60%) and 12 males (40%) with a mean age of 65.2 years (SD 9.3). Mean preoperative hip-knee-ankle deformity was 6.3° varus (SD 2.7°).


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 1 | Pages 126 - 134
1 Feb 1955
Evans DL

1. A simple and effective method of wrist arthrodesis is described. Originally designed for the correction of flexion deformity of the wrist, it is useful also as a routine method of wrist fusion. 2. The results in nineteen cases are reviewed


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 590 - 592
1 May 2004
Yaniv M Ezra E Wientroub S Segev E

A congenital, unilateral, fixed flexion deformity in a neonate was diagnosed as a congenital absence of the knee. A single cartilage mass, with fusion of the lower femoral and upper tibial ossification centres, was demonstrated by imaging studies. This condition has been reported in the literature only once before. Surgery on our patient, which was performed at the age of two years, consisted of separation of the fused cartilaginous anlage and gradual correction of the deformity using an Ilizarov frame


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 204 - 210
1 Mar 1985
McMaster M

Fourteen patients with ankylosing spondylitis had an extension osteotomy for severe flexion deformity of the spine. The Smith-Petersen technique was modified by using a compression device which allows a slow, finely controlled closure of the osteotomy, and provides rigid internal fixation. There were no serious neurological complications. All the patients were able to see straight ahead after operation, and all had solid fusion at nine months, having maintained good correction


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 775 - 778
1 Sep 1990
Barrett D Biswas S MacKenney R

We present a study of 67 Oxford bicompartmental total knee replacements performed at a district general hospital. In this general orthopaedic unit, 57 of the knees (85%) had significant relief of pain with a mean flexion range of 95 degrees and a mean flexion deformity of only 9 degrees. There was a noticeable difference between osteoarthritic and rheumatoid knees. Poor results could be directly related to an avoidable postoperative complication. The results of this independent assessment may be compared favourably with the previously published series from the specialist centre at which the prosthesis was designed


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 3 | Pages 509 - 515
1 Aug 1972
Sallis JG Beighton P

1. A large Caucasian kindred in South Africa are affected by a previously undescribed inherited deformity of the hands and feet called digito-talar dysmorphism. 2. The principal features of digito-talar dysmorphism are flexion deformities, narrowing and ulnar deviation of the fingers. The thumb may be held in an abnormal position by a soft-tissue web. Rocker-bottom foot may develop, due to vertical talus. The facies is normal and the mentality is unimpaired. 3. The general health is good but orthopaedic measures may be needed for function and cosmesis. 4. The condition is transmitted as an autosomal dominant trait, with varying clinical expression of the abnormal gene


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 2 | Pages 355 - 357
1 May 1959
Champion R Cregan JCF

The early management of bilateral congenital popliteal webbing in a brother and sister is described. There was no familial history of webbing, but the maternal grandfather had a hare-lip. Although the sciatic nerve is so unfavourably placed in the web, correction of the flexion deformity can apparently be carried out safely after plastic repair of the skin by Z-plasty and excision of the fibrous web cord alone, without causing a traction paralysis. These cases appear to be unique in that the patients are siblings of different sex with identical congenital abnormalities of bilateral webbing, cleft palate and fistulae of the mucous membrane of the lower lip


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 259 - 262
1 Mar 2001
El-Said NS

Transfer of flexor carpi ulnaris combined with selective release of the flexor pronator origin was undertaken in 35 patients with hemiplegic cerebral palsy for a pronation flexion deformity of the forearm, hand and wrist. The patients were divided into four groups depending on the severity of the deformity, the surgical procedure recommended, potential hand function and prognosis. The procedure reduces the power of wrist and finger flexion by release of the flexor pronator origin, and reinforces the strength of extension and supination of the wrist by transfer of flexor carpi ulnaris. After a mean follow-up of four years the appearance of the hand and forearm improved in all patients. None lost movement and all gained improved mobility of the forearm, wrist and hand. There was no overcorrection


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 541 - 545
1 May 2004
Takwale VJ Stanley JK Shahane SA

In 28 patients with a solitary diagnosis of instability of the trapeziometacarpal joint because of a rupture of the anterior oblique ligament, reconstruction was carried out using a slip of the tendon of flexor carpi radialis. We were able to review 26 patients. The results after a follow-up of four years seven months showed that most (87%) had significant relief from pain and symptoms. Seventeen were graded as good to excellent. The mean grip strength recovered to 86% of the contralateral side. Most patients (81%) felt that they had subjective improvement and would have undergone the operation again. A lesser functional result was seen in those who developed a flexion deformity because of overtightening of the reconstruction. Increased awareness of this lesion can lead to an early and clear diagnosis so that the patient may be advised adequately. We describe a specific, diagnostic, clinical test which we have used consistently and successfully


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 780 - 782
1 Sep 1999
El-Said NS

Twenty complex tibial deformities due to anterior poliomyelitis in 18 patients were corrected by a modified O’Donoghue osteotomy. This technique allowed correction of the deformity in three planes. This was achieved by widening the rectangular window distally to correct both rotation and valgus and by trimming the anterior edges of the step cuts to correct flexion deformity. An above-knee cast was applied for eight to 13 weeks and the patients followed up for a mean of 3.2 years. One of the 18 patients developed delayed union because of fracture of the medial limb of the step cut. The results showed excellent correction of the three-plane deformity and there was no recurrence. This method of osteotomy is a safe and simple procedure which does not require internal fixation and allows correction of torsional and angular deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 843 - 845
1 Sep 1999
Eggli S Hankemayer S Müller ME

We reviewed 508 consecutive total hip replacements in 370 patients with old developmental dysplasia of the hip, to relate the amount of leg lengthening to the incidence of nerve palsies after operation. There were eight nerve palsies (two femoral, six sciatic), two complete and six incomplete. We found no statistical correlation between the amount of lengthening and the incidence of nerve damage (p = 0.47), but in seven of the eight hips, the surgeon had rated the intervention as difficult because of previous surgery, severe deformity, a defect of the acetabular roof, or considerable flexion deformity. The correlation between difficulty and nerve palsy was significant (p = 0.041). We conclude that nerve injury is most commonly caused by direct or indirect mechanical trauma and not by limb lengthening on its own


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 240 - 243
1 Mar 2003
Kulkarni A Fiorenza F Grimer RJ Carter SR Tillman RM

Ten patients underwent endoprosthetic replacement of the distal humerus for bone tumours over a period of 30 years. There were eight primary and two secondary tumours in four men and six women with a mean age of 47.5 years (15 to 76). The mean follow-up was eight years (9 months to 31 years). Four patients required further surgery, three having revision for aseptic loosening; two of these and one other later needing a rebushing. There were no cases of postoperative nerve palsy, infection, local recurrence or mechanical failure of the implant. Four patients died from their disease, all with the prosthesis functioning satisfactorily. At follow-up the mean flexion deformity of the elbow was 15° (0 to 35) and the mean range of flexion was 115° (110 to 135). The functional results showed a mean Toronto extremity salvage score of 73% of normal. Endoprosthetic replacement of the distal humerus and elbow is a satisfactory method of treating these rare tumours


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 197 - 203
1 Mar 1997
McMaster MJ

Fifteen patients with ankylosing spondylitis who had developed a severe flexion deformity of the cervical spine which restricted their field of vision to their feet, were treated by an extension osteotomy at the C7/T1 level. The operation was performed under general anaesthesia with the patient in the prone position and wearing a halo-jacket. Three had internal fixation using a Luque rectangle and wiring. Their mean age was 48 years. Before operation the mean cervical kyphosis was 23°; this was corrected to a mean of 31° of lordosis, a mean correction of 54°. All the patients were able to see straight ahead. One patient with normal neurology soon after operation became quadraparetic after one week; two others had unilateral palsy of the C8 root, which improved. There was subluxation at the site of osteotomy in four patients, and two of them developed a pseudarthrosis which required an anterior fusion


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 939 - 945
1 May 2021
Kakar S Logli AL Ramazanian T Gaston RG Fowler JR

Aims

The purpose was to evaluate early clinical, patient-reported, and radiological outcomes of the scapholunate ligament 360° tenodesis (SL 360) technique for treatment of scapholunate (SL) instability.

Methods

We studied the results of nine patients (eight males and one female with a mean age of 44.7 years (26 to 55)) who underwent the SL 360 procedure for reducible SL instability between January 2016 and June 2019, and who were identified from retrospective review of electronic medical records. Final follow-up of any kind was a mean of 33.7 months (12.0 to 51.3). Clinical, radiological, and patient-reported outcome data included visual analogue scale (VAS) for pain, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), Mayo Wrist Score (MWS), and Patient-Rated Wrist Examination (PRWE). Means were analyzed using paired t-test.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 950 - 955
1 Nov 1993
Harvey I Barry K Kirby S Johnson R Elloy M

We have investigated those factors which influence the range of movement after total knee arthroplasty, including sex, age, preoperative diagnosis and preoperative flexion deformity and flexion range. We also compared cemented and cementless tibial fixation, the influence of collateral ligament and lateral parapatellar releases and of replacement of the patella, and of the period of postoperative immobilisation. We reviewed 516 Johnson-Elloy (Accord) knee arthroplasties performed between 1982 and 1989, with a minimum follow-up of 12 months. The most important factors in the range of flexion achieved after arthroplasty are the diagnosis and the preoperative range of flexion. In patients with osteoarthritis there was a mean loss of flexion; in rheumatoid arthritis there was a mean gain. In both groups, the stiffer knees gained motion and the more mobile knees lost it. Post-operative range of motion was not influenced significantly by cement fixation, collateral ligament or patellar retinacular releases, prolonged immobilisation or patellar replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 564 - 568
1 Jul 1991
Kershaw C Atkins R Dodd C Bulstrode C

The results of 276 cemented revision total hip arthroplasties performed for aseptic failure between 1977 and 1986 have been reviewed. The mean time between revision and review was 75 months (range 30 to 144). Of 220 cases available for review, 159 were assessed clinically and radiographically, and 32 by postal questionnaire. Eighteen hips required further revision, 12 for loosening, two for sepsis, two for persistent pain, and one each for fracture and recurrent dislocation. A further six hips were radiologically and symptomatically loose. Pain was mild or absent in 83%. Over half were able to walk a mile or more; 70% flexed more than 70 degrees; 15% had a flexion deformity, but in only 7% was this more than 10 degrees. The mean Harris hip score was 74. Survival at five years was 95% and at 10 years, 77%


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 760 - 763
1 Sep 1993
Broughton N Menelaus M Cole W Shurtleff D

We studied 1061 children with myelomeningocele, reviewing 3184 pelvic radiographs from 802 patients. Hip dislocation had occurred by the age of 11 years in 28% of children with a thoracic neurosegmental level, 30% of those with an L1/2 level, 36% of L3, 22% of L4, 7% of L5 and only 1% of those with sacral levels. Hip dislocation was not inevitable even when there was maximal muscle imbalance about the hip. The average hip flexion contracture in children aged 9 to 11 years was significantly greater in those with thoracic (22 degrees) and L1/2 (33 degrees) levels than in those with L4 (9 degrees), L5 (5 degrees) or sacral (4 degrees) levels. Our findings indicate that muscle imbalance is not a significant factor in the production of flexion deformity or dislocation of the hip; both are commonly seen in the absence of imbalance. The restoration of muscle balance should no longer be considered to be the principal aim of the management of the hip in children with myelomeningocele


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 692 - 701
1 Nov 1988
Goodfellow J Kershaw C Benson M O'Connor J

The Oxford Knee, a resurfacing prosthesis with a meniscal bearing, can be used for either bicompartmental or unicompartmental arthritis. The first 103 unicompartmental cases are presented at a mean time since operation of 36 months (range 21 to 56 months). In those cases with surviving arthroplasties, pain was relieved in 96%. The full range of pre-operative flexion was maintained and flexion deformity was improved from a mean of 6.7 to 5.4 degrees. Stability and alignment were restored to normal in nearly all the knees. Absence of the anterior cruciate ligament was associated with a significantly greater incidence of failure. Six failures occurred in 37 knees lacking a normal anterior cruciate ligament (16.2%); three occurred in 63 knees with a normal anterior cruciate ligament (4.8%) (p less than 0.02). Criteria for the future selection of patients have been deduced from our experience. The operation is recommended for knees with severe unicompartmental osteoarthritis in which all the ligaments are still intact


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 656 - 659
1 Nov 1984
Stillwell A Menelaus M

Of 47 patients with spina bifida who had had transplantation of the iliopsoas more than 10 years previously, 32 (68%) were community walkers, 3 were household walkers and 12 were non-walkers. Comparison with other published reports showed that, at the very least, the patients reviewed had not had their walking ability jeopardized by the inevitable loss of hip flexor power. Furthermore, all but three of the community walkers were able to climb and descend stairs. There was a high proportion of non-walkers in those patients whose operation had been performed in the first year of life and such early surgery is no longer recommended. We also found that the pre-operative assessment of muscle power had, in some patients, been inaccurate. Finally, we found that, at review, the power of the transferred muscles was poor, suggesting that transplantation is beneficial because it achieves permanent and major reduction in hip flexor power; this usually prevents recurrent hip flexion deformity and dislocation


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 160 - 166
1 May 1975
Sharrard WJW Allen JMH Heaney SH

The clinical and radiological state of the hips of a group of children with cerebral palsy treated without operation is compared with that in a group treated by operation to correct adduction and flexion deformity and to obtain balanced action in the hip muscles. In the first group, 11 per cent of hips were dislocated, 28 per cent subluxated, 46 per cent dysplastic and 15 per cent normal. In the second group no hip was dislocated, 13 per cent were subluxated, 35 per cent dysplastic and 52 per cent normal. Surgical intervention is indicated clinically for a range of abduction diminishing to less than 45 degrees and–on radiological criteria–for early dysplastic changes, especially a break in Shenton's line, irrespective of the patient's age, severity of involvement or neurological maturity. Prevention of subluxation or dislocation improves function and diminishes the liability to develop a painful hip in adolescence or early adult life


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 2 | Pages 337 - 341
1 May 1959
Robins RHC

1. Sixty feet operated upon either by triple or pantalar tarsal fusion for instability after poliomyelitis were re-examined ten to twenty-four years later. 2. After triple fusion with preservation of the ankle joint there was a striking absence of late osteoarthritis of the ankle, and only a low incidence of troublesome lateral instability of the ankle. The results were generally good provided the patient had reasonable power of extension of the knee. 3. Triple arthrodesis for completely flail foot in patients without active muscle control of the knee was often disappointing, so far as the limb as a whole was concerned, because of a persistent flexion deformity of the knee which usually necessitated the wearing of an appliance. 4. The results of pantalar arthrodesis for the flail foot were satisfactory. When this operation was performed (with the foot in slight equinus) in patients who lacked active extension of the knee it helped to stabilise the knee in walking by encouraging hyperextension


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 355 - 361
1 May 1984
Lettin A Kavanagh T Craig D Scales J

We review 210 Stanmore knee replacements in 163 patients to assess the survival of the prostheses and the long-term results. The annual rate of failure reached a maximum of 4.6% in the fourth year after operation; thereafter it declined to reach zero by the eighth year. Between two and eight years after operation, 66.3% of the surviving knees were completely free of pain and 30.2% had mild retropatellar pain. Fixed flexion deformities present before operation were completely corrected in 73% of the knees, and varus or valgus deformities were invariably corrected. Stability was always restored to unstable knees and 80.8% of knees flexed to 90 degrees or more after replacement. Aseptic loosening (8.1%), prosthetic infection (4.3%) and femoral fracture (2.9%) led to 8.5% of the prostheses being revised or removed over eight years. Modifications in prosthetic design and operative techniques have been introduced to minimise such complications in the future


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 486 - 488
1 Aug 1982
Tasker T Waugh W

A prospective study was made of 100 knees which had been operated on for various kinds of internal derangement. An observer, who did not know the clinical condition of the knee, recorded whether or not there were articular lesions of the femoral condyles. Lesions were found to be localised to a triangular area on the medial condyle and to a strip on the lateral condyle. Similar lesions have been described in association with flexion deformities in rheumatoid and osteoarthritic knees. Lesions were found in 49 out of 50 knees which had been locked for more than three days. They were also found in 29 knees in which there appeared to be full extension before operation, but where there was either a torn meniscus with a history of intermittent locking or serious anterolateral instability. In these cases it was considered that the final "screw-home" mechanism of full extension had been lost. Lesions were not present in 10 knees which appeared locked, but in nine of these the interval between injury and operation was less than three days. Lesions were not found in eight knees where there was full extension and no history of locking or instability. In four knees with a plica syndrome similar lesions were present


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 1 | Pages 80 - 86
1 Feb 1967
Pollock GA English TA

1 . A ten-year study of fifty-four operations for transplantation of the hamstring muscles in thirty-one spastic patients has been made. 2. Twenty-one patients were improved after operation, six were not improved, and in four the duration of follow-up was too short for proper assessment. One patient died from other causes. 3. Greatest benefit was not obtained until one year after operation. 4. The results varied considerably in different grades of spastic patient. Important factors affecting the results were age, sex, personality, balance and function of arm and hip. Hand and major hip operations should be carried out before hamstring transplantation. 5. The objectives of operation are discussed. These were most consistently achieved in older, more ambitious or more responsible males with good balance and with good arm and hip function. 6. Factors which were of less direct importance were mental capacity, minor degrees of limb length inequality, and foot deformities. 7. Operative correction of foot deformities should not be done before hamstring transplantation. 8. Serial plaster correction of the knee flexion deformity before operation is preferred to division of the patellar retinacula. 9. Transplantation of the hamstrings to the patella in spastics is under trial


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 286 - 293
1 Feb 2021
Park CH Yan H Park J

Aims

No randomized comparative study has compared the extensile lateral approach (ELA) and sinus tarsi approach (STA) for Sanders type 2 calcaneal fractures. This randomized comparative study was conducted to confirm whether the STA was prone to fewer wound complications than the ELA.

Methods

Between August 2013 and August 2018, 64 patients with Sanders type 2 calcaneus fractures were randomly assigned to receive surgical treatment by the ELA (32 patients) and STA (32 patients). The primary outcome was development of wound complications. The secondary outcomes were postoperative complications, pain scored of a visual analogue scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score, 36-item Short Form health survey, operative duration, subtalar joint range of motion (ROM), Böhler’s angle and calcaneal width, and posterior facet reduction.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 105 - 112
1 Jan 2021
Lynch JT Perriman DM Scarvell JM Pickering MR Galvin CR Neeman T Smith PN

Aims

Modern total knee arthroplasty (TKA) prostheses are designed to restore near normal kinematics including high flexion. Kneeling is a high flexion, kinematically demanding activity after TKA. The debate about design choice has not yet been informed by six-degrees-of-freedom in vivo kinematics. This prospective randomized clinical trial compared kneeling kinematics in three TKA designs.

Methods

In total, 68 patients were randomized to either a posterior stabilized (PS-FB), cruciate-retaining (CR-FB), or rotating platform (CR-RP) design. Of these patients, 64 completed a minimum one year follow-up. Patients completed full-flexion kneeling while being imaged using single-plane fluoroscopy. Kinematics were calculated by registering the 3D implant models onto 2D-dynamic fluoroscopic images and exported for analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 914 - 917
1 Nov 1997
Pope RO Corcoran S McCaul K Howie DW

We report a prospective randomly controlled trial to examine the effectiveness of continuous passive motion (CPM) in improving postoperative function and range of movement after total knee arthroplasty (TKA). We allocated 53 patients (57 knees) to one of three postoperative regimes: no CPM (n = 19); CPM at 0 to 40° (0 to 40 CPM; n = 18); and CPM at 0 to 70° (0 to 70 CPM; n = 20). Those in the CPM groups had CPM for 48 hours and all patients had an identical regime of physiotherapy. There was an even distribution of various cemented and cementless TKAs in each group. Patients were assessed preoperatively and at one week and at one year postoperatively. At one week, there was a statistically significant increase in the range of flexion and total range of movement in the 0 to 70 CPM group compared with the no-CPM group. At one year we found no significant differences in mean flexion, overall range of movement, fixed flexion deformity or functional results in the three groups. Those who had CPM had a significant increase in analgesic requirement (p = 0.04). There was an increased mean blood drainage postoperatively in those who had 0 to 70 CPM (1558 ml) compared with those with no CPM (956 ml) (t = 2.96, p = 0.005) and with 0 to 40 CPM (1017 ml) (t = 2.62, p = 0.01). Our findings show that CPM had no significant advantage in terms of improving function or range of movement, and that its use increased blood loss and analgesic requirements


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1354 - 1358
3 Oct 2020
Noureddine H Vejsbjerg K Harrop JE White MJ Chakravarthy J Harrison JWK

Aims

In the UK, fasciectomy for Dupuytren’s contracture is generally performed under general or regional anaesthetic, with an arm tourniquet and in a hospital setting. We have changed our practice to use local anaesthetic with adrenaline, no arm tourniquet, and perform the surgery in a community setting. We present the outcome of a consecutive series of 30 patients.

Methods

Prospective data were collected for 30 patients undergoing open fasciectomy on 36 digits (six having two digits affected), over a one-year period and under the care of two surgeons. In total, 10 ml to 20 ml volume of 1% lidocaine with 1:100,000 adrenaline was used. A standard postoperative rehabilitation regime was used. Preoperative health scores, goniometer measurements of metacarpophalangeal (MCP), proximal interphalangeal (PIP) contractures, and Unité Rheumatologique des Affections de la Main (URAM) scores were measured pre- and postoperatively at six and 12 weeks.


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 47 - 51
1 Jul 2020
Kazarian GS Schloemann DT Barrack TN Lawrie CM Barrack RL

Aims

The aims of this study were to determine the change in the sagittal alignment of the pelvis and the associated impact on acetabular component position at one-year follow-up after total hip arthroplasty (THA).

Methods

This study represents the one-year follow-up of a previous short-term study at our institution. Using the patient population from our prior study, the radiological pelvic ratio was assessed in 91 patients undergoing THA, of whom 50 were available for follow-up of at least one year (median 1.5; interquartile range (IQR) 1.1 to 2.0). Anteroposterior radiographs of the pelvis were obtained in the standing position preoperatively and at one year postoperatively. Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Apparent acetabular component position changes were determined from the change in pelvic ratio. A change of at least 5° was considered clinically meaningful.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 852 - 860
1 Jul 2020
Zamora T Garbuz DS Greidanus NV Masri BA

Aims

Our objective is to describe our early and mid-term results with the use of a new simple primary knee prosthesis as an articulating spacer in planned two-stage management for infected knee arthroplasty. As a second objective, we compared outcomes between the group with a retained first stage and those with a complete two-stage revision.

Methods

We included 47 patients (48 knees) with positive criteria for infection, with a minimum two-year follow-up, in which a two-stage approach with an articulating spacer with new implants was used. Patients with infection control, and a stable and functional knee were allowed to retain the initial first-stage components. Outcomes recorded included: infection control rate, reoperations, final range of motion (ROM), and quality of life assessment (QoL) including Western Ontario and McMaster Universities osteoarthritis index, Knee Injury and Osteoarthritis Outcome Score, Oxford Knee Score, 12-Item Short-Form Health Survey questionnaire, and University of California Los Angeles (UCLA) activity score and satisfaction score. These outcomes were evaluated and compared to additional cohorts of patients with retained first-stage interventions and those with a complete two-stage revision. Mean follow-up was 3.7 years (2.0 to 6.5).


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 64 - 71
1 Jan 2020
Tsuda Y Fujiwara T Stevenson JD Parry MC Tillman R Abudu A

Aims

The purpose of this study was to report the long-term results of extendable endoprostheses of the humerus in children after the resection of a bone sarcoma.

Methods

A total of 35 consecutive patients treated with extendable endoprosthetic replacement of the humerus in children were included. There were 17 boys and 18 girls in the series with a median age at the time of initial surgery of nine years (interquartile range (IQR) 7 to 11).


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 727 - 735
1 Jun 2020
Burger JA Dooley MS Kleeblad LJ Zuiderbaan HA Pearle AD

Aims

It remains controversial whether patellofemoral joint pathology is a contraindication to lateral unicompartmental knee arthroplasty (UKA). This study aimed to evaluate the effect of preoperative radiological degenerative changes and alignment on patient-reported outcome scores (PROMs) after lateral UKA. Secondarily, the influence of lateral UKA on the alignment of the patellofemoral joint was studied.

Methods

A consecutive series of patients who underwent robotic arm-assisted fixed-bearing lateral UKA with at least two-year follow-up were retrospectively reviewed. Radiological evaluation was conducted to obtain a Kellgren Lawrence (KL) grade, an Altman score, and alignment measurements for each knee. Postoperative PROMs were assessed using the Kujala (Anterior Knee Pain Scale) score, Knee Injury and Osteoarthritis Outcome Score Joint Replacement (KOOS JR), and satisfaction levels.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 49 - 58
1 Jun 2020
Mullaji A

Aims

The aims of this study were to determine the effect of osteophyte excision on deformity correction and soft tissue gap balance in varus knees undergoing computer-assisted total knee arthroplasty (TKA).

Methods

A total of 492 consecutive, cemented, cruciate-substituting TKAs performed for varus osteoarthritis were studied. After exposure and excision of both cruciates and menisci, it was noted from operative records the corrective interventions performed in each case. Knees in which no releases after the initial exposure, those which had only osteophyte excision, and those in which further interventions were performed were identified. From recorded navigation data, coronal and sagittal limb alignment, knee flexion range, and medial and lateral gap distances in maximum knee extension and 90° knee flexion with maximal varus and valgus stresses, were established, initially after exposure and excision of both cruciate ligaments, and then also at trialling. Knees were defined as ‘aligned’ if the hip-knee-ankle axis was between 177° and 180°, (0° to 3° varus) and ‘balanced’ if medial and lateral gaps in extension and at 90° flexion were within 2 mm of each other.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 522 - 528
1 May 2019
Medellin MR Fujiwara T Clark R Stevenson JD Parry M Jeys L

Aims

The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR).

Patients and Methods

In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 108 - 116
1 Jan 2020
Burger JA Kleeblad LJ Laas N Pearle AD

Aims

Limited evidence is available on mid-term outcomes of robotic-arm assisted (RA) partial knee arthroplasty (PKA). Therefore, the purpose of this study was to evaluate mid-term survivorship, modes of failure, and patient-reported outcomes of RA PKA.

Methods

A retrospective review of patients who underwent RA PKA between June 2007 and August 2016 was performed. Patients received a fixed-bearing medial or lateral unicompartmental knee arthroplasty (UKA), patellofemoral arthroplasty (PFA), or bicompartmental knee arthroplasty (BiKA; PFA plus medial UKA). All patients completed a questionnaire regarding revision surgery, reoperations, and level of satisfaction. Knee Injury and Osteoarthritis Outcome Scores (KOOS) were assessed using the KOOS for Joint Replacement Junior survey.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 178 - 188
1 Feb 2019
Chaudhary MM Lakhani PH

Aims

Double-level lengthening, bone transport, and bifocal compression-distraction are commonly undertaken using Ilizarov or other fixators. We performed double-level fixator-assisted nailing, mainly for the correction of deformity and lengthening in the same segment, using a straight intramedullary nail to reduce the time in a fixator.

Patients and Methods

A total of 23 patients underwent this surgery, involving 27 segments (23 femora and four tibiae), over a period of ten years. The most common indication was polio in ten segments and rickets in eight; 20 nails were inserted retrograde and seven antegrade. A total of 15 lengthenings were performed in 11 femora and four tibiae, and 12 double-level corrections of deformity without lengthening were performed in the femur. The mean follow-up was 4.9 years (1.1 to 11.4). Four patients with polio had tibial lengthening with arthrodesis of the ankle. We compared the length of time in a fixator and the external fixation index (EFI) with a control group of 27 patients (27 segments) who had double-level procedures with external fixation. The groups were matched for the gain in length, age, and level of difficulty score.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1438 - 1446
1 Nov 2019
Kong X Chai W Chen J Yan C Shi L Wang Y

Aims

This study aimed to explore whether intraoperative nerve monitoring can identify risk factors and reduce the incidence of nerve injury in patients with high-riding developmental dysplasia.

Patients and Methods

We conducted a historical controlled study of patients with unilateral Crowe IV developmental dysplasia of the hip (DDH). Between October 2016 and October 2017, intraoperative nerve monitoring of the femoral and sciatic nerves was applied in total hip arthroplasty (THA). A neuromonitoring technician was employed to monitor nerve function and inform the surgeon of ongoing changes in a timely manner. Patients who did not have intraoperative nerve monitoring between September 2015 and October 2016 were selected as the control group. All the surgeries were performed by one surgeon. Demographics and clinical data were analyzed. A total of 35 patients in the monitoring group (ten male, 25 female; mean age 37.1 years (20 to 46)) and 56 patients in the control group (13 male, 43 female; mean age 37.9 years (23 to 52)) were enrolled. The mean follow-up of all patients was 13.1 months (10 to 15).


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 915 - 921
1 Aug 2019
Beckers L Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims

Altered alignment and biomechanics are thought to contribute to the progression of osteoarthritis (OA) in the native compartments after medial unicompartmental knee arthroplasty (UKA). The aim of this study was to evaluate the bone activity and remodelling in the lateral tibiofemoral and patellofemoral compartment after medial mobile-bearing UKA.

Patients and Methods

In total, 24 patients (nine female, 15 male) with 25 medial Oxford UKAs (13 left, 12 right) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively and at one and two years postoperatively, along with standard radiographs and clinical outcome scores. The mean patient age was 62 years (40 to 78) and the mean body mass index (BMI) was 29.7 kg/m2 (23.6 to 42.2). Mean osteoblastic activity was evaluated using a tracer localization scheme with volumes of interest (VOIs). Normalized mean tracer values were calculated as the ratio between the mean tracer activity in a VOI and background activity in the femoral diaphysis.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 227 - 232
1 Feb 2019
Walker T Rutkowski L Innmann M Panzram B Herre J Gotterbarm T Aldinger PR Merle C

Aims

The treatment of patients with allergies to metal in total joint arthroplasty is an ongoing debate. Possibilities include the use of hypoallergenic prostheses, as well as the use of standard cobalt-chromium (CoCr) alloy. This non-designer study was performed to evaluate the clinical outcome and survival rates of unicondylar knee arthroplasty (UKA) using a standard CoCr alloy in patients reporting signs of a hypersensitivity to metal.

Patients and Methods

A consecutive series of patients suitable for UKA were screened for symptoms of metal hypersensitivity by use of a questionnaire. A total of 82 patients out of 1737 patients suitable for medial UKA reporting cutaneous metal hypersensitivity to cobalt, chromium, or nickel were included into this study and prospectively evaluated to determine the functional outcome, possible signs of hypersensitivity, and short-term survivorship at a minimum follow-up of 1.5 years.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 331 - 339
1 Mar 2019
McEwen P Balendra G Doma K

Aims

The results of kinematic total knee arthroplasty (KTKA) have been reported in terms of limb and component alignment parameters but not in terms of gap laxities and differentials. In kinematic alignment (KA), balance should reflect the asymmetrical balance of the normal knee, not the classic rectangular flexion and extension gaps sought with gap-balanced mechanical axis total knee arthroplasty (MATKA). This paper aims to address the following questions: 1) what factors determine coronal joint congruence as measured on standing radiographs?; 2) is flexion gap asymmetry produced with KA?; 3) does lateral flexion gap laxity affect outcomes?; 4) is lateral flexion gap laxity associated with lateral extension gap laxity?; and 5) can consistent ligament balance be produced without releases?

Patients and Methods

A total of 192 KTKAs completed by a single surgeon using a computer-assisted technique were followed for a mean of 3.5 years (2 to 5). There were 116 male patients (60%) and 76 female patients (40%) with a mean age of 65 years (48 to 88). Outcome measures included intraoperative gap laxity measurements and component positions, as well as joint angles from postoperative three-foot standing radiographs. Patient-reported outcome measures (PROMs) were analyzed in terms of alignment and balance: EuroQol (EQ)-5D visual analogue scale (VAS), Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS Joint Replacement (JR), and Oxford Knee Score (OKS).


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 59 - 65
1 Jan 2019
Katchky AM Jones CW Walter WL Shimmin AJ

Aims

Between 15% and 20% of patients remain dissatisfied following total knee arthroplasty (TKA). The SAIPH knee system (MatOrtho, Surrey, United Kingdom) is a medial ball and socket TKA that has been designed to replicate native knee kinematics in order to maximize the range of movement, stability, and function. This system is being progressively introduced in a stepwise fashion, with this study reporting the mid-term clinical and radiological outcomes.

Patients and Methods

A retrospective review was undertaken of the first 100 consecutive patients with five-year follow-up following SAIPH TKA performed by the senior authors. The data that were collected included the demographics of the patients, clinical findings, the rate of intraoperative ligamentous release, patient-reported outcome measures (PROMS), radiological assessment, complications, and all-cause revision. Revision data were cross-checked with a national registry.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 213 - 220
1 Feb 2019
Xu S Lim WJ Chen JY Lo NN Chia S Tay DKJ Hao Y Yeo SJ

Aims

The aim of this study was to assess the influence of obesity on the clinical outcomes and survivorship ten years postoperatively in patients who underwent a fixed-bearing unicompartmental knee arthroplasty (UKA).

Patients and Methods

We prospectively followed 184 patients who underwent UKA between 2003 and 2007 for a minimum of ten years. A total of 142 patients with preoperative body mass index (BMI) of < 30 kg/m2 were in the control group (32 male, 110 female) and 42 patients with BMI of ≥ 30 kg/m2 were in the obese group (five male, 37 female). Pre- and postoperative range of movement (ROM), Knee Society Score (KSS), Oxford Knee Score (OKS), 36-Item Short-Form Health Survey (SF-36), and survivorship were analyzed.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 24 - 33
1 Jan 2019
Kayani B Konan S Tahmassebi J Rowan FE Haddad FS

Aims

The objectives of this study were to compare postoperative pain, analgesia requirements, inpatient functional rehabilitation, time to hospital discharge, and complications in patients undergoing conventional jig-based unicompartmental knee arthroplasty (UKA) versus robotic-arm assisted UKA.

Patients and Methods

This prospective cohort study included 146 patients with symptomatic medial compartment knee osteoarthritis undergoing primary UKA performed by a single surgeon. This included 73 consecutive patients undergoing conventional jig-based mobile bearing UKA, followed by 73 consecutive patients receiving robotic-arm assisted fixed bearing UKA. All surgical procedures were performed using the standard medial parapatellar approach for UKA, and all patients underwent the same postoperative rehabilitation programme. Postoperative pain scores on the numerical rating scale and opiate analgesia consumption were recorded until discharge. Time to attainment of predefined functional rehabilitation outcomes, hospital discharge, and postoperative complications were recorded by independent observers.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1640 - 1646
1 Dec 2018
Medellin MR Fujiwara T Clark R Jeys LM

Aims

The aim of this study was to describe, analyze, and compare the survival, functional outcome, and complications of minimally invasive (MI) and non-invasive (NI) lengthening total femoral prostheses.

Patients and Methods

A total of 24 lengthening total femoral prostheses, 11 MI and 13 NI, were implanted between 1991 and 2016. The characteristics, complications, and functional results were recorded. There were ten female patients and ten male patients. Their mean age at the time of surgery was 11 years (2 to 41). The mean follow-up was 13.2 years (seven months to 29.25 years). A survival analysis was performed, and the failures were classified according to the Modified Henderson System.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1625 - 1634
1 Dec 2016
Scott CEH Oliver WM MacDonald D Wade FA Moran M Breusch SJ

Aims

Risk of revision following total knee arthroplasty (TKA) is higher in patients under 55 years, but little data are reported regarding non-revision outcomes. This study aims to identify predictors of dissatisfaction in these patients.

Patients and Methods

We prospectively assessed 177 TKAs (157 consecutive patients, 99 women, mean age 50 years; 17 to 54) from 2008 to 2013. Age, gender, implant, indication, body mass index (BMI), social deprivation, range of movement, Kellgren-Lawrence (KL) grade of osteoarthritis (OA) and prior knee surgery were recorded. Pre- and post-operative Oxford Knee Score (OKS) as well as Short Form-12 physical (PCS) and mental component scores were obtained. Post-operative range of movement, complications and satisfaction were measured at one year.


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 42 - 49
1 Jan 2018
Walker T Zahn N Bruckner T Streit MR Mohr G Aldinger PR Clarius M Gotterbarm T

Aims

The aim of this independent multicentre study was to assess the mid-term results of mobile bearing unicondylar knee arthroplasty (UKA) for isolated lateral osteoarthritis of the knee joint.

Patients and Methods

We retrospectively evaluated 363 consecutive, lateral UKAs (346 patients) performed using the Oxford domed lateral prosthesis undertaken in three high-volume knee arthroplasty centres between 2006 and 2014. Mean age of the patients at surgery was 65 years (36 to 88) with a mean final follow-up of 37 months (12 to 93)


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1382 - 1388
1 Oct 2016
Laubscher M Mitchell C Timms A Goodier D Calder P

Aims

Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages.

Patients and Methods

We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1043 - 1049
1 Aug 2016
Huijbregts HJTAM Khan RJK Fick DP Hall MJ Punwar SA Sorensen E Reid MJ Vedove SD Haebich S

Aims

We conducted a randomised controlled trial to assess the accuracy of positioning and alignment of the components in total knee arthroplasty (TKA), comparing those undertaken using standard intramedullary cutting jigs and those with patient-specific instruments (PSI).

Patients and Methods

There were 64 TKAs in the standard group and 69 in the PSI group.

The post-operative hip-knee-ankle (HKA) angle and positioning was investigated using CT scans. Deviation of > 3° from the planned position was regarded as an outlier. The operating time, Oxford Knee Scores (OKS) and Short Form-12 (SF-12) scores were recorded.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1050 - 1055
1 Aug 2016
Karachalios T Varitimidis S Bargiotas K Hantes M Roidis N Malizos KN

Aims

The Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary data regarding the kinematics of the knee. We wished to examine the long-term results obtained with this prosthesis by extending a previous evaluation.

Patients and Methods

We retrospectively evaluated prospectively collected data from 225 consecutive patients (41 men and 184 women; mean age at surgery 71 years, 52 to 84) who underwent 284 TKAs with a mean follow-up of 13.4 years (11 to 15). Implant failure, complication rate, clinical (both subjective and objective) and radiological outcome were assessed. Pre- and post-operative clinical and radiographic data were available at regular intervals for all patients. A total of ten patients (4.4%; ten TKAs) were lost to follow-up.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 60 - 64
1 Jan 2017
Lange J Haas SB

Valgus knee deformity can present a number of unique surgical challenges for the total knee arthroplasty (TKA) surgeon. Understanding the typical patterns of bone and soft-tissue pathology in the valgus arthritic knee is critical for appropriate surgical planning. This review aims to provide the knee arthroplasty surgeon with an understanding of surgical management strategies for the treatment of valgus knee arthritis.

Lateral femoral and tibial deficiencies, contracted lateral soft tissues, attenuated medial soft tissues, and multiplanar deformities may all be present in the valgus arthritic knee. A number of classifications have been reported in order to guide surgical management, and a variety of surgical strategies have been described with satisfactory clinical results. Depending on the severity of the deformity, a variety of TKA implant designs may be appropriate for use.

Regardless of an operating surgeon’s preferred surgical strategy, adherence to a step-wise approach to deformity correction is advised.

Cite this article: Bone Joint J 2017;99-B(1 Supple A):60–4.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 84 - 88
1 Jan 2016
Vince K

The term mid-flexion instability has entered the orthopaedic literature as a concept, but has not been confirmed as a distinct clinical entity. The term is used freely, sometimes as a synonym for flexion instability. However, the terms need to be clearly separated. A cadaver study published in 1990 associated joint line elevation with decreased stability at many angles of flexion, but that model was not typical of clinical scenarios. The literature is considered and it is proposed that the more common entity of an uncorrected flexion contracture after a measured resection arthroplasty technique is more likely to produce clinical findings that suggest instability mid-flexion.

It is proposed that the clinical scenario encountered is generalised instability, with the appearance of stability in full extension from tight posterior structures.

This paper seeks to clarify whether mid-flexion instability exists as an entity distinct from other commonly recognised forms of instability.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):84–8.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 360 - 365
1 Mar 2014
Zheng GQ Zhang YG Chen JY Wang Y

Few studies have examined the order in which a spinal osteotomy and total hip replacement (THR) are to be performed for patients with ankylosing spondylitis. We have retrospectively reviewed 28 consecutive patients with ankylosing spondylitis who underwent both a spinal osteotomy and a THR from September 2004 to November 2012. In the cohort 22 patients had a spinal osteotomy before a THR (group 1), and six patients had a THR before a spinal osteotomy (group 2). The mean duration of follow-up was 3.5 years (2 to 9). The spinal sagittal Cobb angle of the vertebral osteotomy segment was corrected from a pre-operative kyphosis angle of 32.4 (SD 15.5°) to a post-operative lordosis 29.6 (SD 11.2°) (p < 0.001). Significant improvements in pain, function and range of movement were observed following THR. In group 2, two of six patients had an early anterior dislocation. The spinal osteotomy was performed two weeks after the THR. At follow-up, no hip has required revision in either group. Although this non-comparative study only involved a small number of patients, given our experience, we believe a spinal osteotomy should be performed prior to a THR, unless the deformity is so severe that the procedure cannot be performed.

Cite this article: Bone Joint J 2014;96-B:360–5.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 282 - 288
1 Feb 2016
Putz C Döderlein L Mertens EM Wolf SI Gantz S Braatz F Dreher T

Aims

Single-event multilevel surgery (SEMLS) has been used as an effective intervention in children with bilateral spastic cerebral palsy (BSCP) for 30 years. To date there is no evidence for SEMLS in adults with BSCP and the intervention remains focus of debate.

Methods

This study analysed the short-term outcome (mean 1.7 years, standard deviation 0.9) of 97 ambulatory adults with BSCP who performed three-dimensional gait analysis before and after SEMLS at one institution.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1165 - 1171
1 Sep 2013
Arastu MH Kokke MC Duffy PJ Korley REC Buckley RE

Coronal plane fractures of the posterior femoral condyle, also known as Hoffa fractures, are rare. Lateral fractures are three times more common than medial fractures, although the reason for this is not clear. The exact mechanism of injury is likely to be a vertical shear force on the posterior femoral condyle with varying degrees of knee flexion. These fractures are commonly associated with high-energy trauma and are a diagnostic and surgical challenge. Hoffa fractures are often associated with inter- or supracondylar distal femoral fractures and CT scans are useful in delineating the coronal shear component, which can easily be missed. There are few recommendations in the literature regarding the surgical approach and methods of fixation that may be used for this injury. Non-operative treatment has been associated with poor outcomes. The goals of treatment are anatomical reduction of the articular surface with rigid, stable fixation to allow early mobilisation in order to restore function. A surgical approach that allows access to the posterior aspect of the femoral condyle is described and the use of postero-anterior lag screws with or without an additional buttress plate for fixation of these difficult fractures.

Cite this article: Bone Joint J 2013;95-B:1165–71.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1055 - 1058
1 Aug 2008
Lee HS Kim JS Park S Lee D Park JM Wapner KL

We studied 11 patients with checkrein deformities of the hallux who underwent surgical treatment. Six had lengthening of the flexor hallucis longus tendon by Z-plasty in the midfoot, and five underwent release of adhesions and lengthening of the tendon by Z-plasty at the musculotendinous junction at the fracture site.

All six patients who underwent Z-plasty at the midfoot showed complete correction of the deformity without recurrence. Of the five who had release of adhesions and Z-plasty of the tendon at the fracture site, two showed partial and one showed complete recurrence.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1252 - 1257
1 Sep 2014
Habib M Tanwar YS Jaiswal A Singh SP Sinha S lal H

In order to achieve satisfactory reduction of complex distal humeral fractures, adequate exposure of the fracture fragments and the joint surface is required. Several surgical exposures have been described for distal humeral fractures. We report our experience using the anconeus pedicle olecranon flip osteotomy approach. This involves detachment of the triceps along with a sliver of olecranon, which retains the anconeus pedicle. We report the use of this approach in ten patients (six male, four female) with a mean age of 38.4 years (28 to 51). The mean follow-up was 15 months (12 to 18) with no loss to follow-up. Elbow function was graded using the Mayo Score. The results were excellent in four patients, good in five and fair in one patient. The mean time to both fracture and osteotomy union was 10.6 weeks (8 to 12) and 7.1 weeks (6 to 8), respectively. We found this approach gave reliably good exposure for these difficult fractures enabling anatomical reduction and bicondylar plating without complications.

Cite this article: Bone Joint J 2014;96-B:1252–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1362 - 1365
1 Oct 2012
Seah RB Pang HN Lo NN Chong HC Chin PL Chia SL Yeo SJ

The success of total knee replacement (TKR) depends on optimal soft-tissue balancing, among many other factors. The objective of this study is to correlate post-operative anteroposterior (AP) translation of a posterior cruciate ligament-retaining TKR with clinical outcome at two years. In total 100 patients were divided into three groups based on their AP translation as measured by the KT-1000 arthrometer. Group 1 patients had AP translation < 5 mm, Group 2 had AP translation from 5 mm to 10 mm, and Group 3 had AP translation >  10 mm. Outcome assessment included range of movement of the knee, the presence of flexion contractures, hyperextension, knee mechanical axes and functional outcome using the Knee Society score, Oxford knee score and the Short-Form 36 questionnaire.

At two years, patients in Group 2 reported significantly better Oxford knee scores than the other groups (p = 0.045). A positive correlation between range of movement and AP translation was noted, with patients in group 3 having the greatest range of movement (mean flexion: 117.9° (106° to 130°)) (p < 0.001). However, significantly more patients in Group 3 developed hyperextension > 10° (p = 0.01).

In this study, the best outcome for cruciate-ligament retaining TKR was achieved in patients with an AP translation of 5 mm to 10 mm.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 267 - 272
1 Feb 2010
Abdel-Ghani H Ebeid W El-Barbary H

We describe the management of nonunion combined with limb-length discrepancy following vascularised fibular grafting for the reconstruction of long-bone defects in the lower limb after resection of a tumour in skeletally immature patients. We operated on nine patients with a mean age of 13.1 years (10.5 to 14.5) who presented with a mean limb-length discrepancy of 7 cm (4 to 9) and nonunion at one end of a vascularised fibular graft, which had been performed previously, to reconstruct a bone defect after resection of an osteosarcoma.

Reconstruction was carried out using a ring fixator secured with correction by half pins of any malalignment, compression of the site of nonunion and lengthening through a metaphyseal parafocal osteotomy without bone grafting. The expected limb-length discrepancy at maturity was calculated using the arithmetic method. Solid union and the intended leg length were achieved in all the patients. Excessive scarring and the distorted anatomy from previous surgery in these patients required other procedures to be performed with minimal exposures and dissection in order to avoid further compromise to the vascularity of the graft or damage to neurovascular structures. The methods which we chose were simple and effective in addressing these complex problems.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 12 - 18
1 Jan 2011
Eastwood DM Sanghrajka AP

Guiding growth by harnessing the ability of growing bone to undergo plastic deformation is one of the oldest orthopaedic principles. Correction of deformity remains a major part of the workload for paediatric orthopaedic surgeons and recently, along with developments in limb reconstruction and computer-directed frame correction, there has been renewed interest in surgical methods of physeal manipulation or ‘guided growth’. Manipulating natural bone growth to correct a deformity is appealing, as it allows gradual correction by non- or minimally invasive methods.

This paper reviews the techniques employed for guided growth in current orthopaedic practice, including the basic science and recent advances underlying mechanical physeal manipulation of both healthy and pathological physes.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 801 - 802
1 Jun 2008
Lahoti O Bajaj S

Most cases of club foot (congenital talipes equinovarus) respond to non-operative treatment but resistant cases may need surgery. It is broadly accepted that lengthening of tendo Achillis, the tendon of tibialis posterior and capsulotomy of the ankle and subtalar joints are necessary during surgical release, but there is no consensus as to whether lengthening of the tendons of flexor hallucis longus and flexor digitorum longus is required.

We randomised 13 children with severe bilateral club foot deformities to undergo lengthening of the flexor hallucis longus and flexor digitorum longus tendons on one side and simple decompression on the other. We found no difference in the deformities of the toes between the lengthened and non-lengthened sides at a mean follow-up of four years (2 to 6).

We conclude that routine lengthening of the tendons of flexor hallucis longus and flexor digitorum longus during soft-tissue surgery for resistant club foot is not necessary.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 345 - 349
1 Mar 2014
Liddle AD Pandit HG Jenkins C Lobenhoffer P Jackson WFM Dodd CAF Murray DW

The cementless Oxford unicompartmental knee replacement has been demonstrated to have superior fixation on radiographs and a similar early complication rate compared with the cemented version. However, a small number of cases have come to our attention where, after an apparently successful procedure, the tibial component subsides into a valgus position with an increased posterior slope, before becoming well-fixed. We present the clinical and radiological findings of these six patients and describe their natural history and the likely causes. Two underwent revision in the early post-operative period, and in four the implant stabilised and became well-fixed radiologically with a good functional outcome.

This situation appears to be avoidable by minor modifications to the operative technique, and it appears that it can be treated conservatively in most patients.

Cite this article: Bone Joint J 2014;96-B:345–9.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1290 - 1297
1 Oct 2014
Grammatopoulos G Pandit HG da Assunção R McLardy-Smith P De Smet KA Gill HS Murray DW

There is great variability in acetabular component orientation following hip replacement. The aims of this study were to compare the component orientation at impaction with the orientation measured on post-operative radiographs and identify factors that influence the difference between the two. A total of 67 hip replacements (52 total hip replacements and 15 hip resurfacings) were prospectively studied. Intra-operatively, the orientation of the acetabular component after impaction relative to the operating table was measured using a validated stereo-photogrammetry protocol. Post-operatively, the radiographic orientation was measured; the mean inclination/anteversion was 43° (sd 6°)/ 19° (sd 7°). A simulated radiographic orientation was calculated based on how the orientation would have appeared had an on-table radiograph been taken intra-operatively. The mean difference between radiographic and intra-operative inclination/anteversion was 5° (sd 5°)/ -8° (sd 8°). The mean difference between simulated radiographic and intra-operative inclination/anteversion, which quantifies the effect of the different way acetabular orientation is measured, was 3°/-6° (sd 2°). The mean difference between radiographic and simulated radiographic orientation inclination/anteversion, which is a manifestation of the change in pelvic position between component impaction and radiograph, was 1°/-2° (sd 7°).

This study demonstrated that in order to achieve a specific radiographic orientation target, surgeons should implant the acetabular component 5° less inclined and 8° more anteverted than their target. Great variability (2 sd about ± 15°) in the post-operative radiographic cup orientation was seen. The two equally contributing causes for this are variability in the orientation at which the cup is implanted, and the change in pelvic position between impaction and post-operative radiograph.

Cite this article: Bone Joint J 2014;96-B:1290–7


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1005 - 1015
1 Aug 2014
Alshryda S Sukeik M Sarda P Blenkinsopp J Haddad FS Mason JM

Intravenous tranexamic acid (TXA) has been shown to be effective in reducing blood loss and the need for transfusion after joint replacement. Recently, there has been interest in applying it topically before the closure of surgical wounds. This has the advantages of ease of application, maximum concentration at the site of bleeding, minimising its systemic absorption and, consequently, concerns about possible side-effects.

We conducted a systematic review and meta-analysis which included 14 randomised controlled trials (11 in knee replacement, two in hip replacement and one in both) which investigated the effect of topical TXA on blood loss and rates of transfusion. Topical TXA significantly reduced the rate of blood transfusion (total knee replacement: risk ratio (RR) 4.51; 95% confidence interval (CI): 3.02 to 6.72; p < 0.001 (nine trials, I2 = 0%); total hip replacement: RR 2.56; 95% CI: 1.32 to 4.97, p = 0.004 (one trial)). The rate of thromboembolic events with topical TXA were similar to those found with a placebo. Indirect comparison of placebo-controlled trials of topical and intravenous TXA indicates that topical administration is superior to the intravenous route.

In conclusion, topical TXA is an effective and safe method of reducing the need for blood transfusion after total knee and hip replacement. Further research is required to find its optimum dose for topical use.

Cite this article: Bone Joint J 2014;96-B:1005–15.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1612 - 1617
1 Dec 2009
Venkatesh KP Modi HN Devmurari K Yoon JY Anupama BR Song HR

Extensive limb lengthening may be indicated in achondroplastic patients who wish to achieve a height within the normal range for their population. However, increasing the magnitude of lengthening is associated with further complications particularly adjacent joint stiffness and fractures. We studied the relationship between the magnitude of femoral lengthening and callus pattern, adjacent joint stiffness and fracture of the regenerate bone in 40 femoral lengthenings in 20 achondroplastic patients. They were divided into two groups; group A had lengthening of less than 50% and group B of more than 50% of their initial femoral length. The patterns of radiological callus formation were classified according to shape, type and features. The incidence of callus features, knee stiffness and regenerate bone fracture were analysed in the two groups. Group B was associated with an increased incidence of concave, lateral and central callus shapes, adjacent joint and stiffness and fracture. Statistically, the incidence of stiffness in adjacent joints and regenerate bone fracture was significantly associated with the magnitude of lengthening.

We suggest that careful radiological assessment of the patterns of callus formation is a useful method for the evaluation and monitoring of regenerate bone.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 729 - 733
1 Jun 2015
Thomas SRYW

Successful management of late presenting hip dislocation in childhood is judged by the outcome not just at skeletal maturity but well beyond into adulthood and late middle age. This review considers different methods of treatment and looks critically at the handful of studies reporting long-term follow-up after successful reduction.

Cite this article: Bone Joint J 2015;97-B:729–33.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1640 - 1644
1 Dec 2013
Agarwal S Azam A Morgan-Jones R

Bone loss in the proximal tibia and distal femur is frequently encountered in revision knee replacement surgery. The various options for dealing with this depend on the extent of any bone loss. We present our results with the use of cementless metaphyseal metal sleeves in 103 patients (104 knees) with a mean follow-up of 43 months (30 to 65). At final follow-up, sleeves in 102 knees had good osseointegration. Two tibial sleeves were revised for loosening, possibly due to infection.

The average pre-operative Oxford Knee Score was 23 (11 to 36) and this improved to 32 (15 to 46) post-operatively. These early results encourage us to continue with the technique and monitor the outcomes in the long term.

Cite this article: Bone Joint J 2013;95-B:1640–4.