Advertisement for orthosearch.org.uk
Results 1 - 74 of 74
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 269 - 276
1 Mar 2023
Tay ML Monk AP Frampton CM Hooper GJ Young SW

Aims. Unicompartmental knee arthroplasty (UKA) has higher revision rates than total knee arthroplasty (TKA). As revision of UKA may be less technically demanding than revision TKA, UKA patients with poor functional outcomes may be more likely to be offered revision than TKA patients with similar outcomes. The aim of this study was to compare clinical thresholds for revisions between TKA and UKA using revision incidence and patient-reported outcomes, in a large, matched cohort at early, mid-, and late-term follow-up. Methods. Analyses were performed on propensity score-matched patient cohorts of TKAs and UKAs (2:1) registered in the New Zealand Joint Registry between 1 January 1999 and 31 December 2019 with an Oxford Knee Score (OKS) response at six months (n, TKA: 16,774; UKA: 8,387), five years (TKA: 6,718; UKA: 3,359), or ten years (TKA: 3,486; UKA: 1,743). Associations between OKS and revision within two years following the score were examined. Thresholds were compared using receiver operating characteristic analysis. Reasons for aseptic revision were compared using cumulative incidence with competing risk. Results. Fewer TKA patients with ‘poor’ outcomes (≤ 25) subsequently underwent revision compared with UKA at six months (5.1% vs 19.6%; p < 0.001), five years (4.3% vs 12.5%; p < 0.001), and ten years (6.4% vs 15.0%; p = 0.024). Compared with TKA, the relative risk for UKA was 2.5-times higher for ‘unknown’ reasons, bearing dislocations, and disease progression. Conclusion. Compared with TKA, more UKA patients with poor outcomes underwent revision from early to long-term follow-up, and were more likely to undergo revision for ‘unknown’ reasons, which suggest a lower clinical threshold for UKA. For UKA, revision risk was higher for bearing dislocations and disease progression. There is supporting evidence that the higher revision UKA rates are associated with lower clinical thresholds for revision and additional modes of failure. Cite this article: Bone Joint J 2023;105-B(3):269–276


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims. Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up. Methods. This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36). Results. There were no differences between the two treatment groups with regard to mean change in haemoglobin concentration (p = 0.477), length of stay (LOS, p = 0.172), mean polyethylene thickness (p = 0.065), or postoperative complication rates (p = 0.295). At the most recent follow-up, the primary robotic arm-assisted TKA group had a statistically significantly improved OKS compared with the revision UKA to TKA group (44.6 (SD 2.7) vs 42.3 (SD 2.5); p = 0.004) but there was no difference in the overall ROM (p = 0.056) or FJS between the two treatment groups (86.1 (SD 9.6) vs 84.1 (4.9); p = 0.439). Conclusion. Robotic arm-assisted revision of UKA to TKA was associated with comparable intraoperative blood loss, early postoperative rehabilitation, functional outcomes, and complications to primary robotic TKA at short-term follow-up. Robotic arm-assisted surgery offers a safe and reproducible technique for revising failed UKA to TKA. Cite this article: Bone Joint J 2024;106-B(7):680–687


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1367 - 1372
1 Aug 2021
Plancher KD Brite JE Briggs KK Petterson SC

Aims

The patient-acceptable symptom state (PASS) is a level of wellbeing, which is measured by the patient. The aim of this study was to determine if the proportion of patients who achieved an acceptable level of function (PASS) after medial unicompartmental knee arthroplasty (UKA) was different based on the status of the anterior cruciate ligament (ACL) at the time of surgery.

Methods

A total of 114 patients who underwent UKA for isolated medial osteoarthritis (OA) of the knee were included in the study. Their mean age was 65 years (SD 10). No patient underwent a bilateral procedure. Those who had undergone ACL reconstruction during the previous five years were excluded. The Knee injury Osteoarthritis Outcome Score Activities of Daily Living (KOOS ADL) function score was used as the primary outcome measure with a PASS of 87.5, as described for total knee arthroplasty (TKA). Patients completed all other KOOS subscales, Lysholm score, the Western Ontario and McMaster Universities Osteoarthritis Index, and the Veterans Rand 12-item health survey score. Failure was defined as conversion to TKA.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1561 - 1570
1 Oct 2021
Blyth MJG Banger MS Doonan J Jones BG MacLean AD Rowe PJ

Aims

The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively.

Methods

A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status.


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 672 - 679
1 Jun 2022
Tay ML Young SW Frampton CM Hooper GJ

Aims. Unicompartmental knee arthroplasty (UKA) has a higher risk of revision than total knee arthroplasty (TKA), particularly for younger patients. The outcome of knee arthroplasty is typically defined as implant survival or revision incidence after a defined number of years. This can be difficult for patients to conceptualize. We aimed to calculate the ‘lifetime risk’ of revision for UKA as a more meaningful estimate of risk projection over a patient’s remaining lifetime, and to compare this to TKA. Methods. Incidence of revision and mortality for all primary UKAs performed from 1999 to 2019 (n = 13,481) was obtained from the New Zealand Joint Registry (NZJR). Lifetime risk of revision was calculated for patients and stratified by age, sex, and American Society of Anesthesiologists (ASA) grade. Results. The lifetime risk of revision was highest in the youngest age group (46 to 50 years; 40.4%) and decreased sequentially to the oldest (86 to 90 years; 3.7%). Across all age groups, lifetime risk of revision was higher for females (ranging from 4.3% to 43.4% vs males 2.9% to 37.4%) and patients with a higher ASA grade (ASA 3 to 4, ranging from 8.8% to 41.2% vs ASA 1 1.8% to 29.8%). The lifetime risk of revision for UKA was double that of TKA across all age groups (ranging from 3.7% to 40.4% for UKA, and 1.6% to 22.4% for TKA). The higher risk of revision in younger patients was associated with aseptic loosening in both sexes and pain in females. Periprosthetic joint infection (PJI) accounted for 4% of all UKA revisions, in contrast with 27% for TKA; the risk of PJI was higher for males than females for both procedures. Conclusion. Lifetime risk of revision may be a more meaningful measure of arthroplasty outcomes than implant survival at defined time periods. This study highlights the higher lifetime risk of UKA revision for younger patients, females, and those with a higher ASA grade, which can aid with patient counselling prior to UKA. Cite this article: Bone Joint J 2022;104-B(6):672–679


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 23 - 31
1 Jun 2021
Burnett III RA Yang J Courtney PM Terhune EB Hannon CP Della Valle CJ

Aims. The aim of this study was to compare ten-year longitudinal healthcare costs and revision rates for patients undergoing unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA). Methods. The Humana database was used to compare 2,383 patients undergoing UKA between 2007 and 2009, who were matched 1:1 from a cohort of 63,036 patients undergoing primary TKA based on age, sex, and Elixhauser Comorbidity Index. Medical and surgical complications were tracked longitudinally for one year following surgery. Rates of revision surgery and cumulative mean healthcare costs were recorded for this period of time and compared between the cohorts. Results. Patients undergoing TKA had significantly higher rates of manipulation under anaesthesia (3.9% vs 0.9%; p < 0.001), deep vein thrombosis (5.0% vs 3.1%; p < 0.001), pulmonary embolism (1.5% vs 0.8%; p = 0.001), and renal failure (4.2% vs 2.2%; p < 0.001). Revision rates, however, were significantly higher for UKA at five years (6.0% vs 4.2%; p = 0.007) and ten years postoperatively (6.5% vs 4.4%; p = 0.002). Longitudinal-related healthcare costs for patients undergoing TKA were greater than for those undergoing UKA at one year ($24,771 vs $22,071; p < 0.001) and five years following surgery ($26,549 vs $25,730; p < 0.001); however, the mean costs of TKA were comparable to UKA at ten years ($26,877 vs $26,891; p = 0.425). Conclusion. Despite higher revision rates, patients undergoing UKA had lower mean healthcare costs than those undergoing TKA up to ten years following the procedure, at which time costs were comparable. In the era of value-based care, surgeons and policymakers should be aware of the costs involved with these procedures. UKA was associated with fewer complications at one year postoperatively but higher revision rates at five and ten years. While UKA was significantly less costly than TKA at one and five years, costs at ten years were comparable with a mean difference of only $14. Lowering the risk of revision surgery should be targeted as a source of cost savings for both UKA and TKA as the mean related healthcare costs were 2.5-fold higher in patients requiring revision surgery. Cite this article: Bone Joint J 2021;103-B(6 Supple A):23–31


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 610 - 618
1 Apr 2021
Batailler C Bordes M Lording T Nigues A Servien E Calliess T Lustig S

Aims. Ideal component sizing may be difficult to achieve in unicompartmental knee arthroplasty (UKA). Anatomical variants, incremental implant size, and a reduced surgical exposure may lead to over- or under-sizing of the components. The purpose of this study was to compare the accuracy of UKA sizing with robotic-assisted techniques versus a conventional surgical technique. Methods. Three groups of 93 medial UKAs were assessed. The first group was performed by a conventional technique, the second group with an image-free robotic-assisted system (Image-Free group), and the last group with an image-based robotic arm-assisted system, using a preoperative CT scan (Image-Based group). There were no demographic differences between groups. We compared six parameters on postoperative radiographs to assess UKA sizing. Incorrect sizing was defined by an over- or under-sizing greater than 3 mm. Results. There was a higher rate of tibial under-sizing posteriorly in the conventional group compared to robotic-assisted groups (47.3% (n = 44) in conventional group, 29% (n = 27) in Image-Free group, 6.5% (n = 6) in Image-Based group; p < 0.001), as well as a higher rate of femoral under-sizing posteriorly (30.1% (n = 28) in conventional group, 7.5% (n = 7) in Image-Free group, 12.9% (n = 12) in Image-Based group; p < 0.001). The posterior femoral offset was more often increased in the conventional group, especially in comparison to the Image-Based group (43% (n = 40) in conventional group, 30.1% (n = 28) in Image-Free group, 8.6% (n = 8) in Image-Based group; p < 0.001). There was no significant overhang of the femoral or tibial implant in any groups. Conclusion. Robotic-assisted surgical techniques for medial UKA decrease the risk of tibial and femoral under-sizing, particularly with an image-based system using a preoperative CT scan. Cite this article: Bone Joint J 2021;103-B(4):610–618


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 91 - 95
1 Jun 2020
Johnson, Jr. WB Engh, Jr. CA Parks NL Hamilton WG Ho PH Fricka KB

Aims. It has been hypothesized that a unicompartmental knee arthroplasty (UKA) is more likely to be revised than a total knee arthroplasty (TKA) because conversion surgery to a primary TKA is a less complicated procedure. The purpose of this study was to determine if there is a lower threshold for revising a UKA compared with TKA based on Oxford Knee Scores (OKSs) and range of movement (ROM) at the time of revision. Methods. We retrospectively reviewed 619 aseptic revision cases performed between December 1998 and October 2018. This included 138 UKAs that underwent conversion to TKA and 481 initial TKA revisions. Age, body mass index (BMI), time in situ, OKS, and ROM were available for all patients. Results. There were no differences between the two groups based on demographics or time to revision. The top reasons for aseptic TKA revision were loosening in 212 (44%), instability in 88 (18%), and wear in 69 (14%). UKA revision diagnoses were primarily for loosening in 50 (36%), progression of osteoarthritis (OA) in 50 (36%), and wear in 17 (12%). Out of a maximum 48 points, the mean OKS of the UKAs before revision was 23 (SD 9.3), which was significantly higher than the TKAs at 19.2 (SD 9.8; p < 0.001). UKA patients scored statistically better on nine of the 12 individual OKS questions. The UKA cases also had a larger pre-revision mean ROM (114°, SD 14.3°) than TKAs (98°, SD 25°) ; p < 0.001). Conclusion. At revision, the mean UKA OKSs and ROM were significantly better than those of TKA cases. This study suggests that at our institution there is a difference in preoperative OKS between UKA and TKA at the time of revision, demonstrating a revision bias. Cite this article: Bone Joint J 2020;102-B(6 Supple A):91–95


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 34 - 44
1 Jan 2022
Beckers L Dandois F Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims. Higher osteoblastic bone activity is expected in aseptic loosening and painful unicompartmental knee arthroplasty (UKA). However, insights into normal bone activity patterns after medial UKAs are lacking. The aim of this study was to identify the evolution in bone activity pattern in well-functioning medial mobile-bearing UKAs. Methods. In total, 34 patients (13 female, 21 male; mean age 62 years (41 to 79); BMI 29.7 kg/m. 2. (23.6 to 42.1)) with 38 medial Oxford partial UKAs (20 left, 18 right; 19 cementless, 14 cemented, and five hybrid) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively, and at one and two years postoperatively. Changes in mean osteoblastic activity were investigated using a tracer localization scheme with volumes of interest (VOIs), reported by normalized mean tracer values. A SPECT/CT registration platform additionally explored cortical tracer evolution in zones of interest identified by previous experimental research. Results. Significant reduction of tracer activity from the preoperative situation was found in femoral and anteromedial tibial VOIs adjacent to the UKA components. Temporarily increased osteoblastic bone activity was observed in VOIs comprising the UKA keel structure at one year postoperatively compared to the preoperative activity. Persistent higher tracer uptake was found in the posterior tibial cortex at final follow-up. Multivariate analysis showed no statistical difference in osteoblastic bone activity underneath cemented or cementless components. Conclusion. Well-functioning medial mobile-bearing UKAs showed distinct changes in patterns of normalized bone tracer activity in the different VOIs adjacent to the prosthetic components, regardless of their type of fixation. Compared to the preoperative situation, persistent high bone activity was found underneath the keel and the posterior tibial cortex at final follow-up, with significant reduced activity only being identified in femoral and anteromedial tibial VOIs. Cite this article: Bone Joint J 2022;104-B(1):34–44


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1167 - 1175
14 Sep 2020
Gromov K Petersen PB Jørgensen CC Troelsen A Kehlet H

Aims. The aim of this prospective multicentre study was to describe trends in length of stay and early complications and readmissions following unicompartmental knee arthroplasty (UKA) performed at eight different centres in Denmark using a fast-track protocol and to compare the length of stay between centres with high and low utilization of UKA. Methods. We included data from eight dedicated fast-track centres, all reporting UKAs to the same database, between 2010 and 2018. Complete ( > 99%) data on length of stay, 90-day readmission, and mortality were obtained during the study period. Specific reasons for a length of stay of > two days, length of stay > four days, and 30- and 90-day readmission were recorded. The use of UKA in the different centres was dichotomized into ≥ 20% versus < 20% of arthroplasties which were undertaken being UKAs, and ≥ 52 UKAs versus < 52 UKAs being undertaken annually. Results. A total of 3,927 procedures were included. Length of stay (mean 1.1 days (SD 1.1), median 1 (IQR 0 to 1)) was unchanged during the study period. The proportion of procedures with a length of stay > two days was also largely unchanged during this time. The percentage of patients discharged on the day of surgery varied greatly between centres (0% to 50% (0 to 481)), with centres with high UKA utilization (both usage and volume) having a larger proportion of same-day discharges. The 30- and 90-day readmissions were 166 (4.2%) and 272 (6.9%), respectively; the 90-day mortality was 0.08% (n = 3). Conclusion. Our findings suggest general underutilization of the potential for quicker recovery following UKA in a fast-track setup. Cite this article: Bone Joint J 2020;102-B(9):1167–1175


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1063 - 1070
1 Sep 2019
Clement ND Deehan DJ Patton JT

Aims. The primary aim of the study was to perform an analysis to identify the cost per quality-adjusted life-year (QALY) of robot-assisted unicompartmental knee arthroplasty (rUKA) relative to manual total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA) for patients with isolated medial compartment osteoarthritis (OA) of the knee. Secondary aims were to assess how case volume and length of hospital stay influenced the relative cost per QALY. Patients and Methods. A Markov decision analysis was performed, using known parameters for costs, outcomes, implant survival, and mortality, to assess the cost-effectiveness of rUKA relative to manual TKA and UKA for patients with isolated medial compartment OA of the knee with a mean age of 65 years. The influence of case volume and shorter hospital stay were assessed. Results. Using a model with an annual case volume of 100 patients, the cost per QALY of rUKA was £1395 and £1170 relative to TKA and UKA, respectively. The cost per QALY was influenced by case volume: a low-volume centre performing ten cases per year would achieve a cost per QALY of £7170 and £8604 relative to TKA and UKA. For a high-volume centre performing 200 rUKAs per year with a mean two-day length of stay, the cost per QALY would be £648; if performed as day-cases, the cost would be reduced to £364 relative to TKA. For a high-volume centre performing 200 rUKAs per year with a shorter length of stay of one day relative to manual UKA, the cost per QALY would be £574. Conclusion . rUKA is a cost-effective alternative to manual TKA and UKA for patients with isolated medial compartment OA of the knee. The cost per QALY of rUKA decreased with reducing length of hospital stay and with increasing case volume, compared with TKA and UKA. Cite this article: Bone Joint J 2019;101-B:1063–1070


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1033 - 1040
1 Aug 2020
Kennedy JA Mohammad HR Yang I Mellon SJ Dodd CAF Pandit HG Murray DW

Aims. To report mid- to long-term results of Oxford mobile bearing domed lateral unicompartmental knee arthroplasty (UKA), and determine the effect of potential contraindications on outcome. Methods. A total of 325 consecutive domed lateral UKAs undertaken for the recommended indications were included, and their functional and survival outcomes were assessed. The effects of age, weight, activity, and the presence of full-thickness erosions of cartilage in the patellofemoral joint on outcome were evaluated. Results. Median follow-up was seven years (3 to 14), and mean age at surgery was 65 years (39 to 90). Median Oxford Knee Score (OKS) was 43 (interquartile range (IQR) 37 to 47), with 260 (80%) achieving a good or excellent score (OKS > 34). Revisions occurred in 34 (10%); 14 (4%) were for dislocation, of which 12 had no recurrence following insertion of a new bearing, and 12 (4%) were revised for medial osteoarthritis (OA). Ten-year survival was 85% (95% confidence interval (CI) 79 to 90, at risk 72). Age, weight, activity, and patellofemoral erosions did not have a significant effect on the clinical outcome or survival. Conclusion. Domed lateral UKA provides a good alternative to total knee arthroplasty (TKA) in the management of lateral compartment OA. Although dislocation is relatively easy to treat successfully, the dislocation rate of 4% is high. It is recommended that the stability of the bearing is assessed intraoperatively. If the bearing can easily be displaced, the fixed rather than the mobile bearing version of the Oxford lateral tibial component should be inserted instead. Younger age, heavier weight, high activity, and patellofemoral erosions did not detrimentally affect outcome, so should not be considered contraindications. Cite this article: Bone Joint J 2020;102-B(8):1033–1040


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1088 - 1095
1 Jun 2021
Banger M Doonan J Rowe P Jones B MacLean A Blyth MJB

Aims. Unicompartmental knee arthroplasty (UKA) is a bone-preserving treatment option for osteoarthritis localized to a single compartment in the knee. The success of the procedure is sensitive to patient selection and alignment errors. Robotic arm-assisted UKA provides technological assistance to intraoperative bony resection accuracy, which is thought to improve ligament balancing. This paper presents the five-year outcomes of a comparison between manual and robotically assisted UKAs. Methods. The trial design was a prospective, randomized, parallel, single-centre study comparing surgical alignment in patients undergoing UKA for the treatment of medial compartment osteoarthritis (ISRCTN77119437). Participants underwent surgery using either robotic arm-assisted surgery or conventional manual instrumentation. The primary outcome measure (surgical accuracy) has previously been reported, and, along with secondary outcomes, were collected at one-, two-, and five-year timepoints. Analysis of five-year results and longitudinal analysis for all timepoints was performed to compare the two groups. Results. Overall, 104 (80%) patients of the original 130 who received surgery were available at five years (55 robotic, 49 manual). Both procedures reported successful results over all outcomes. At five years, there were no statistical differences between the groups in any of the patient reported or clinical outcomes. There was a lower reintervention rate in the robotic arm-assisted group with 0% requiring further surgery compared with six (9%) of the manual group requiring additional surgical intervention (p < 0.001). Conclusion. This study has shown excellent clinical outcomes in both groups with no statistical or clinical differences in the patient-reported outcome measures. The notable difference was the lower reintervention rate at five years for roboticarm-assisted UKA when compared with a manual approach. Cite this article: Bone Joint J 2021;103-B(6):1088–1095


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 727 - 735
1 Jun 2020
Burger JA Dooley MS Kleeblad LJ Zuiderbaan HA Pearle AD

Aims. It remains controversial whether patellofemoral joint pathology is a contraindication to lateral unicompartmental knee arthroplasty (UKA). This study aimed to evaluate the effect of preoperative radiological degenerative changes and alignment on patient-reported outcome scores (PROMs) after lateral UKA. Secondarily, the influence of lateral UKA on the alignment of the patellofemoral joint was studied. Methods. A consecutive series of patients who underwent robotic arm-assisted fixed-bearing lateral UKA with at least two-year follow-up were retrospectively reviewed. Radiological evaluation was conducted to obtain a Kellgren Lawrence (KL) grade, an Altman score, and alignment measurements for each knee. Postoperative PROMs were assessed using the Kujala (Anterior Knee Pain Scale) score, Knee Injury and Osteoarthritis Outcome Score Joint Replacement (KOOS JR), and satisfaction levels. Results. A total of 140 knees (130 patients) were identified for analysis. At mean 4.1 years (2.0 to 8.5) follow-up, good to excellent Kujala scores were reported. The presence of mild to moderate preoperative patellofemoral joint osteoarthritis had no impact on these scores (KL grade 0 vs 1 to 3, p = 0.203; grade 0 to 1 vs 2 to 3, p = 0.674). Comparable scores were reported by patients with osteoarthritis (Altman score of ≥ 2) evident on either the medial or lateral patellofemoral joint facet (medial, p = 0.600 and lateral, p = 0.950). Patients with abnormal patellar congruence and tilt angles (≥ 17° and ≥ 14°, respectively) reported good to excellent Kujala scores. Furthermore, lateral UKA resulted in improvements to patellofemoral alignment. Conclusion. This is the first study demonstrating that mild to moderate preoperative radiological degenerative changes and malalignment of the patellofemoral joint are not associated with poor patient-reported outcomes at mid-term follow-up after lateral fixed-bearing UKA. Our data suggest that this may be explained by realignment of the patella and thereby redistribution of loads across the patellofemoral joint. Cite this article: Bone Joint J 2020;102-B(6):727–735


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 103 - 110
1 Jul 2021
Chalmers BP Lebowitz JS Chiu Y Joseph AD Padgett DE Bostrom MPG Gonzalez Della Valle A

Aims. Due to the opioid epidemic in the USA, our service progressively decreased the number of opioid tablets prescribed at discharge after primary hip (THA) and knee (TKA) arthroplasty. The goal of this study was to analyze the effect on total morphine milligram equivalents (MMEs) prescribed and post-discharge opioid repeat prescriptions. Methods. We retrospectively reviewed 19,428 patients undergoing a primary THA or TKA between 1 February 2016 and 31 December 2019. Two reductions in the number of opioid tablets prescribed at discharge were implemented over this time; as such, we analyzed three periods (P1, P2, and P3) with different routine discharge MME (750, 520, and 320 MMEs, respectively). We investigated 90-day refill rates, refill MMEs, and whether discharge MMEs were associated with represcribing in a multivariate model. Results. A discharge prescription of < 400 MMEs was not a risk factor for opioid represcribing in the entire population (p = 0.772) or in opioid-naïve patients alone (p = 0.272). Procedure type was the most significant risk factor for narcotic represcribing, with unilateral TKA (hazard ratio (HR) = 5.62), bilateral TKA (HR = 6.32), and bilateral unicompartmental knee arthroplasty (UKA) (HR = 5.29) (all p < 0.001) being the highest risk for refills. For these three procedures, there was approximately a 5% to 6% increase in refills from P1 to P3 (p < 0.001); however, there was no significant increase in refill rates after any hip arthroplasty procedures. Total MMEs prescribed were significantly reduced from P1 to P3 (p < 0.001), leading to the equivalent of nearly 500,000 fewer oxycodone 5 mg tablets prescribed. Conclusion. Decreasing opioids prescribed at discharge led to a statistically significant reduction in total MMEs prescribed. While the represcribing rate did not increase for any hip arthroplasty procedure, the overall refill rates increased by about 5% for most knee arthroplasty procedures. As such, we are now probably prescribing an appropriate amount of opioids at discharge for knee arthroplasty procedure, but further reductions may be possible for hip arthroplasty procedures. Cite this article: Bone Joint J 2021;103-B(7 Supple B):103–110


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 24 - 33
1 Jan 2019
Kayani B Konan S Tahmassebi J Rowan FE Haddad FS

Aims. The objectives of this study were to compare postoperative pain, analgesia requirements, inpatient functional rehabilitation, time to hospital discharge, and complications in patients undergoing conventional jig-based unicompartmental knee arthroplasty (UKA) versus robotic-arm assisted UKA. Patients and Methods. This prospective cohort study included 146 patients with symptomatic medial compartment knee osteoarthritis undergoing primary UKA performed by a single surgeon. This included 73 consecutive patients undergoing conventional jig-based mobile bearing UKA, followed by 73 consecutive patients receiving robotic-arm assisted fixed bearing UKA. All surgical procedures were performed using the standard medial parapatellar approach for UKA, and all patients underwent the same postoperative rehabilitation programme. Postoperative pain scores on the numerical rating scale and opiate analgesia consumption were recorded until discharge. Time to attainment of predefined functional rehabilitation outcomes, hospital discharge, and postoperative complications were recorded by independent observers. Results. Robotic-arm assisted UKA was associated with reduced postoperative pain (p < 0.001), decreased opiate analgesia requirements (p < 0.001), shorter time to straight leg raise (p < 0.001), decreased number of physiotherapy sessions (p < 0.001), and increased maximum knee flexion at discharge (p < 0.001) compared with conventional jig-based UKA. Mean time to hospital discharge was reduced in robotic UKA compared with conventional UKA (42.5 hours (. sd 5.9). vs 71.1 hours (. sd. 14.6), respectively; p < 0.001). There was no difference in postoperative complications between the two groups within 90 days’ follow-up. Conclusion. Robotic-arm assisted UKA was associated with decreased postoperative pain, reduced opiate analgesia requirements, improved early functional rehabilitation, and shorter time to hospital discharge compared with conventional jig-based UKA


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 435 - 442
1 Apr 2019
Zambianchi F Franceschi G Rivi E Banchelli F Marcovigi A Nardacchione R Ensini A Catani F

Aims. The purpose of this multicentre observational study was to investigate the association between intraoperative component positioning and soft-tissue balancing on short-term clinical outcomes in patients undergoing robotic-arm assisted unicompartmental knee arthroplasty (UKA). Patients and Methods. Between 2013 and 2016, 363 patients (395 knees) underwent robotic-arm assisted UKAs at two centres. Pre- and postoperatively, patients were administered Knee Injury and Osteoarthritis Score (KOOS) and Forgotten Joint Score-12 (FJS-12). Results were stratified as “good” and “bad” if KOOS/FJS-12 were more than or equal to 80. Intraoperative, post-implantation robotic data relative to CT-based components placement were collected and classified. Postoperative complications were recorded. Results. Following exclusions and losses to follow-up, 334 medial robotic-arm assisted UKAs were assessed at a mean follow-up of 30.0 months (8.0 to 54.9). None of the measured parameters were associated with overall KOOS outcome. Correlations were described between specific KOOS subscales and intraoperative, post-implantation robotic data, and between FJS-12 and femoral component sagittal alignment. Three UKAs were revised, resulting in 99.0% survival at two years (95% confidence interval (CI) 97.9 to 100.0). Conclusion. Although little correlation was found between intraoperative robotic data and overall clinical outcome, surgeons should consider information regarding 3D component placement and soft-tissue balancing to improve patient satisfaction. Reproducible and precise placement of components has been confirmed as essential for satisfactory clinical outcome. Cite this article: Bone Joint J 2019;101-B:435–442


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 407 - 413
1 Apr 2020
Vermue H Lambrechts J Tampere T Arnout N Auvinet E Victor J

The application of robotics in the operating theatre for knee arthroplasty remains controversial. As with all new technology, the introduction of new systems might be associated with a learning curve. However, guidelines on how to assess the introduction of robotics in the operating theatre are lacking. This systematic review aims to evaluate the current evidence on the learning curve of robot-assisted knee arthroplasty. An extensive literature search of PubMed, Medline, Embase, Web of Science, and Cochrane Library was conducted. Randomized controlled trials, comparative studies, and cohort studies were included. Outcomes assessed included: time required for surgery, stress levels of the surgical team, complications in regard to surgical experience level or time needed for surgery, size prediction of preoperative templating, and alignment according to the number of knee arthroplasties performed. A total of 11 studies met the inclusion criteria. Most were of medium to low quality. The operating time of robot-assisted total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA) is associated with a learning curve of between six to 20 cases and six to 36 cases respectively. Surgical team stress levels show a learning curve of seven cases in TKA and six cases for UKA. Experience with the robotic systems did not influence implant positioning, preoperative planning, and postoperative complications. Robot-assisted TKA and UKA is associated with a learning curve regarding operating time and surgical team stress levels. Future evaluation of robotics in the operating theatre should include detailed measurement of the various aspects of the total operating time, including total robotic time and time needed for preoperative planning. The prior experience of the surgical team should also be evaluated and reported. Cite this article: Bone Joint J 2020;102-B(4):407–413


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 319 - 328
1 Mar 2020
St Mart J de Steiger RN Cuthbert A Donnelly W

Aim. There has been a significant reduction in unicompartmental knee arthroplasty (UKA) procedures recorded in Australia. This follows several national joint registry studies documenting high UKA revision rates when compared to total knee arthroplasty (TKA). With the recent introduction of robotically assisted UKA procedures, it is hoped that outcomes improve. This study examines the cumulative revision rate of UKA procedures implanted with a newly introduced robotic system and compares the results to one of the best performing non-robotically assisted UKA prostheses, as well as all other non-robotically assisted UKA procedures. Methods. Data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) for all UKA procedures performed for osteoarthritis (OA) between 2015 and 2018 were analyzed. Procedures using the Restoris MCK UKA prosthesis implanted using the Mako Robotic-Arm Assisted System were compared to non-robotically assisted Zimmer Unicompartmental High Flex Knee System (ZUK) UKA, a commonly used UKA with previously reported good outcomes and to all other non-robotically assisted UKA procedures using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship. Results. There was no difference in the rate of revision when the Mako-assisted Restoris UKA was compared to the ZUK UKA (zero to nine months: HR 1.14 (95% CI 0.71 to 1.83; p = 0.596) vs nine months and over: HR 0.66 (95% CI 0.42 to 1.02; p = 0.058)). The Mako-assisted Restoris had a significantly lower overall revision rate compared to the other types of non-robotically assisted procedures (HR 0.58 (95% confidence interval (CI) 0.42 to 0.79); p < 0.001) at three years. Revision for aseptic loosening was lower for the Mako-assisted Restoris compared to all other non-robotically assisted UKA (entire period: HR 0.34 (95% CI 0.17 to 0.65); p = 0.001), but not the ZUK prosthesis. However, revision for infection was significantly higher for the Mako-assisted Restoris compared to the two comparator groups (ZUK: entire period: HR 2.91 (95% CI 1.22 to 6.98; p = 0.016); other non-robotically assisted UKA: zero to three months: HR 5.57 (95% CI 2.17 to 14.31; p < 0.001)). Conclusion. This study reports comparable short-term survivorship for the Mako robotically assisted UKA compared to the ZUK UKA and improved survivorship compared to all other non-robotic UKA. These results justify the continued use and investigation of this procedure. However, the higher rate of early revision for infection for robotically assisted UKA requires further investigation. Cite this article: Bone Joint J 2020;102-B(3):319–328


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 22 - 27
1 Jul 2019
Kalbian IL Tan TL Rondon AJ Bonaddio VA Klement MR Foltz C Lonner JH

Aims. Unicompartmental knee arthroplasty (UKA) provides improved early functional outcomes and less postoperative morbidity and pain compared with total knee arthroplasty (TKA). Opioid prescribing has increased in the last two decades, and recently states in the USA have developed online Prescription Drug Monitoring Programs to prevent overprescribing of controlled substances. This study evaluates differences in opioid requirements between patients undergoing TKA and UKA. Patients and Methods. We retrospectively reviewed 676 consecutive TKAs and 241 UKAs. Opioid prescriptions in morphine milligram equivalents (MMEs), sedatives, benzodiazepines, and stimulants were collected from State Controlled Substance Monitoring websites six months before and nine months after the initial procedures. Bivariate and multivariate analysis were performed for patients who had a second prescription and continued use. Results. Patients undergoing UKA had a second opioid prescription filled 50.2% of the time, compared with 60.5% for TKA (p = 0.006). After controlling for potential confounders, patients undergoing UKA were still less likely to require a second prescription than those undergoing TKA (adjusted odds ratio (OR) 0.58, 95% confidence interval (CI) 0.42 to 0.81; p = 0.001). Continued opioid use requiring more than five prescriptions occurred in 13.7% of those undergoing TKA and 5.8% for those undergoing UKA (p = 0.001), and was also reduced in UKA patients compared with TKA patients (adjusted OR 0.33, 95% CI 0.16 to 0.67; p = 0.022) in multivariate analysis. The continued use of opioids after six months was 11.8% in those undergoing TKA and 8.3% in those undergoing UKA (p = 0.149). The multivariate models for second prescriptions, continued use with more than five, and continued use beyond six months yielded concordance scores of 0.70, 0.86, and 0.83, respectively. Conclusion. Compared with TKA, patients undergoing UKA are less likely to require a second opioid prescription and use significantly fewer opioid prescriptions. Thus, orthopaedic surgeons should adjust their patterns of prescription and educate patients about the reduced expected analgesic requirements after UKA compared with TKA. Cite this article: Bone Joint J 2019;101-B(7 Supple C):22–27


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 108 - 116
1 Jan 2020
Burger JA Kleeblad LJ Laas N Pearle AD

Aims. Limited evidence is available on mid-term outcomes of robotic-arm assisted (RA) partial knee arthroplasty (PKA). Therefore, the purpose of this study was to evaluate mid-term survivorship, modes of failure, and patient-reported outcomes of RA PKA. Methods. A retrospective review of patients who underwent RA PKA between June 2007 and August 2016 was performed. Patients received a fixed-bearing medial or lateral unicompartmental knee arthroplasty (UKA), patellofemoral arthroplasty (PFA), or bicompartmental knee arthroplasty (BiKA; PFA plus medial UKA). All patients completed a questionnaire regarding revision surgery, reoperations, and level of satisfaction. Knee Injury and Osteoarthritis Outcome Scores (KOOS) were assessed using the KOOS for Joint Replacement Junior survey. Results. Mean follow-up was 4.7 years (2.0 to 10.8). Five-year survivorship of medial UKA (n = 802), lateral UKA (n = 171), and PFA/BiKA (n = 35/10) was 97.8%, 97.7%, and 93.3%, respectively. Component loosening and progression of osteoarthritis (OA) were the most common reasons for revision. Mean KOOS scores after medial UKA, lateral UKA, and PFA/BiKA were 84.3 (SD 15.9), 85.6 (SD 14.3), and 78.2 (SD 14.2), respectively. The vast majority of the patients reported high satisfaction levels after RA PKA. Subgroup analyses suggested tibial component design, body mass index (BMI), and age affects RA PKA outcomes. Five-year survivorship was 98.4% (95% confidence interval (CI) 97.2 to 99.5) for onlay medial UKA (n = 742) and 99.1% (95% CI 97.9 to 100) for onlay medial UKA in patients with a BMI < 30 kg/m. 2. (n = 479). Conclusion. This large single-surgeon study showed high mid-term survivorship, satisfaction levels, and functional outcomes in RA UKA using metal-backed tibial onlay components. In addition, favourable results were reported in RA PFA and BiKA. Cite this article: Bone Joint J 2020;102-B(1):108–116


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 213 - 220
1 Feb 2019
Xu S Lim WJ Chen JY Lo NN Chia S Tay DKJ Hao Y Yeo SJ

Aims. The aim of this study was to assess the influence of obesity on the clinical outcomes and survivorship ten years postoperatively in patients who underwent a fixed-bearing unicompartmental knee arthroplasty (UKA). Patients and Methods. We prospectively followed 184 patients who underwent UKA between 2003 and 2007 for a minimum of ten years. A total of 142 patients with preoperative body mass index (BMI) of < 30 kg/m. 2. were in the control group (32 male, 110 female) and 42 patients with BMI of ≥ 30 kg/m. 2. were in the obese group (five male, 37 female). Pre- and postoperative range of movement (ROM), Knee Society Score (KSS), Oxford Knee Score (OKS), 36-Item Short-Form Health Survey (SF-36), and survivorship were analyzed. Results. Patients in the obese group underwent UKA at a significantly younger mean age (56.5 years (. sd. 6.4)) than those in the control group (62.4 years (. sd. 7.8); p < 0.001). There was no significant difference in preoperative functional scores. However, those in the obese group had a significantly lower ROM (116° (. sd. 15°) vs 123° (. sd. 17°); p = 0.003). Both groups achieved significant improvement in outcome scores regardless of BMI, ten years postoperatively. All patients achieved the minimal clinically important difference (MCID) for OKS and KSS. Both groups also had high rates of satisfaction (96.3% in the control group and 97.5% in the obese group) and the fulfilment of expectations (94.9% in the control group and 95.0% in the obese group). Multiple linear regression showed a clear association between obesity and a lower OKS two years postoperatively and Knee Society Function Score (KSFS) ten years postoperatively. After applying propensity matching, obese patients had a significantly lower KSFS, OKS, and physical component score (PCS) ten years postoperatively. Seven patients underwent revision to total knee arthroplasty (TKA), two in the control group and five in the obese group, resulting in a mean rate of survival at ten years of 98.6% and 88.1%, respectively (p = 0.012). Conclusion. Both groups had significant improvements in functional and quality-of-life scores postoperatively. However, obesity was a significant predictor of poorer improvement in clinical outcome and an increased rate of revision ten years postoperatively


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 65 - 69
1 Jan 2017
Thienpont E

Objectives. Unicompartmental knee arthroplasty (UKA) is a potential treatment for isolated bone on bone osteoarthritis when limited to a single compartment. The risk for revision of UKA is three times higher than for total knee arthroplasty (TKA). The aim of this review was to discuss the different revision options after UKA failure. Materials and Methods. A search was performed for English language articles published between 2006 and 2016. After reviewing titles and abstracts, 105 papers were selected for further analysis. Of these, 39 papers were deemed to contain clinically relevant data to be included in this review. Results. The most common reasons for failure are liner dislocation, aseptic loosening, disease progression of another compartment and unexplained pain. . UKA can be revised to or with another UKA if the failure mode allows reconstruction of the joint with UKA components. In case of disease progression another UKA can be added, either at the patellofemoral joint or at the remaining tibiofemoral joint. Often the accompanying damage to the knee joint doesn’t allow these two former techniques resulting in a primary TKA. In a third of cases, revision TKA components are necessary. This is usually on the tibial side where augments and stems might be required. Conclusions. In case of failure of UKA, several less invasive revision techniques remain available to obtain primary results. Revision in a late stage of failure or because of surgical mistakes might ask for the use of revision components limiting the clinical outcome for the patients. Cite this article: Bone Joint J 2017;99-B(1 Supple A):65–9


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 62 - 67
1 Jan 2018
Bedard NA DeMik DE Dowdle SB Callaghan JJ

Aims. The purpose of this study was to evaluate trends in opioid use after unicompartmental knee arthroplasty (UKA), to identify predictors of prolonged use and to compare the rates of opioid use after UKA, total knee arthroplasty (TKA) and total hip arthroplasty (THA). Materials and Methods. We identified 4205 patients who had undergone UKA between 2007 and 2015 from the Humana Inc. administrative claims database. Post-operative opioid use for one year post-operatively was assessed using the rates of monthly repeat prescription. These were then compared between patients with and without a specific variable of interest and with those of patients who had undergone TKA and THA. Results. A total of 4205 UKA patients were analysed. Of these, 1362 patients (32.4%) were users of opioids. Pre-operative opioid use was the strongest predictor of prolonged opioid use after UKA. Opioid users were 1.4 (81.6% versus 57.7%), 3.7 (49.5% versus 13.3%) and 5.5 (35.8% versus 6.5%) times more likely to be taking opioids at one, two and three months post-operatively, respectively (p < 0.05 for all). Younger age and specific comorbidities such as anxiety/depression, smoking, back pain and substance abuse were found to significantly increase the rate of repeat prescription for opioids after UKA. Overall, UKA patients required significantly less opioid prescriptions than patients who had undergone THA and TKA. Conclusion. One-third of patients who undergo UKA are given opioids in the three months pre-operatively. Pre-operative opioid use is the best predictor of increased repeat prescriptions after UKA. However, other intrinsic patient characteristics are also predictive. Cite this article: Bone Joint J 2018;100-B(1 Supple A):62–7


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 840 - 845
1 May 2021
Rossi SMP Perticarini L Clocchiatti S Ghiara M Benazzo F

Aims. In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term follow-up. Methods. A total of 57 procedures were performed. In 45 cases, a PFA was associated with a medial UKA and, in 12, with a lateral UKA. Patients were followed with validated patient-reported outcome measures (Oxford Knee Score (OKS), EuroQol five-dimension questionnaire (EQ-5D), EuroQoL Visual Analogue Scale (EQ-VAS)), the Knee Society Score (KSS), the Forgotten Joint Score (FJS), and radiological analysis. Results. The mean follow-up was nine years (6 to 13). All scores significantly improved from preoperatively to final follow-up (mean and SD): OKS from 23.2 (8.1) to 42.5 (3.5), EQ-5D from 0.44 (0.25) to 0.815 (0.1), EQ-VAS from 46.7 (24.9) to 89.1 (9.8), KSS (Knee) from 51.4 (8.5) to 94.4 (4.2), and KSS (Function) from 48.7 (5.5) to 88.8 (5.2). The mean FJS at final follow-up was 79.2 (4.2). All failures involved the medial UKA + PFA group. Overall, survival rate was 91.5% for all the combined implants at ten years with 95% confidence intervals and 22 knees at risk. Conclusion. Excellent clinical and radiological outcomes were achieved after a third-generation PFA combined with a medial or lateral UKA. BCA with unlinked partial knee prostheses showed a good survival rate at mid- to long-term follow-up. Cite this article: Bone Joint J 2021;103-B(5):840–845


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 788 - 792
1 Jun 2017
Bradley B Middleton S Davis N Williams M Stocker M Hockings M Isaac DL

Aims. Unicompartmental knee arthroplasty (UKA) has been successfully performed in the United States healthcare system on outpatients. Despite differences in healthcare structure and financial environment, we hypothesised that it would be feasible to replicate this success and perform UKA with safe day of surgery discharge within the NHS, in the United Kingdom. This has not been reported in any other United Kingdom centres. Patients and Methods. We report our experience of implementing a pathway to allow safe day of surgery discharge following UKA. Data were prospectively collected on 72 patients who underwent UKA as a day case between December 2011 and September 2015. . Results. A total of 61 patients (85%) were discharged on the same day. The most common reason for failure was logistical; five patients had their operation too late in the day. Three patients failed to mobilise safely, two had inadequate control of pain and one had a leaking wound. The mean length of stay for those who were not discharged on the same day was 1.2 nights (1 to 3). During the same time, 58 patients underwent planned inpatient UKA, as they were deemed inappropriate for discharge on the day of surgery. However, three of these were safely discharged on the same day. Follow-up data, 24 hours post-operatively, were available for 70 patients; 51 (73%) reported no or mild pain, 14 (20%) had moderate pain and five (7%) had severe pain. There were no re-admissions. All patients had a high level of satisfaction. Conclusion. We found that patients can be safely and effectively discharged on the day of surgery after UKA, with high levels of satisfaction. This clearly offers improved management of resources and financial savings to healthcare trusts. Cite this article: Bone Joint J 2017;99-B:788–92


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1506 - 1511
1 Nov 2015
Liddle AD Pandit H Judge A Murray DW

Unicompartmental knee arthroplasty (UKA) has advantages over total knee arthroplasty but national joint registries report a significantly higher revision rate for UKA. As a result, most surgeons are highly selective, offering UKA only to a small proportion (up to 5%) of patients requiring arthroplasty of the knee, and consequently performing few each year. However, surgeons with large UKA practices have the lowest rates of revision. The overall size of the practice is often beyond the surgeon’s control, therefore case volume may only be increased by broadening the indications for surgery, and offering UKA to a greater proportion of patients requiring arthroplasty of the knee. . The aim of this study was to determine the optimal UKA usage (defined as the percentage of knee arthroplasty practice comprised by UKA) to minimise the rate of revision in a sample of 41 986 records from the for National Joint Registry for England and Wales (NJR). UKA usage has a complex, non-linear relationship with the rate of revision. Acceptable results are achieved with the use of 20% or more. Optimal results are achieved with usage between 40% and 60%. Surgeons with the lowest usage (up to 5%) have the highest rates of revision. With optimal usage, using the most commonly used implant, five-year survival is 96% (95% confidence interval (CI) 94.9 to 96.0), compared with 90% (95% CI 88.4 to 91.6) with low usage (5%) previously considered ideal. . The rate of revision of UKA is highest with low usage, implying the use of narrow, and perhaps inappropriate, indications. The widespread use of broad indications, using appropriate implants, would give patients the advantages of UKA, without the high rate of revision. Cite this article: Bone Joint J 2015;97-B:1506–11


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 41 - 47
1 Oct 2016
Lisowski LA Meijer LI Bekerom MPJVD Pilot P Lisowski AE

Aims. The interest in unicompartmental knee arthroplasty (UKA) for medial osteoarthritis has increased rapidly but the long-term follow-up of the Oxford UKAs has yet to be analysed in non-designer centres. We have examined our ten- to 15-year clinical and radiological follow-up data for the Oxford Phase III UKAs. Patients and Methods. Between January 1999 and January 2005 a total of 138 consecutive Oxford Phase III arthroplasties were performed by a single surgeon in 129 patients for medial compartment osteoarthritis (71 right and 67 left knees, mean age 72.0 years (47 to 91), mean body mass index 28.2 (20.7 to 52.2)). Both clinical data and radiographs were prospectively recorded and obtained at intervals. Of the 129 patients, 32 patients (32 knees) died, ten patients (12 knees) were not able to take part in the final clinical and radiological assessment due to physical and mental conditions, but via telephone interview it was confirmed that none of these ten patients (12 knees) had a revision of the knee arthroplasty. One patient (two knees) was lost to follow-up. Results. The mean follow-up was 11.7 years (10 to 15). A total of 11 knees (8%) were revised. The survival at 15 years with revision for any reason as the endpoint was 90.6% (95% confidence interval (CI) 85.2 to 96.0) and revision related to the prosthesis was 99.3% (95% CI 97.9 to 100). The mean total Knee Society Score was 47 (0 to 80) pre-operatively and 81 (30 to 100) at latest follow-up. The mean Oxford Knee Score was 19 (12 to 40) pre-operatively and 42 (28 to 55) at final follow-up. Radiolucency beneath the tibial component occurred in 22 of 81 prostheses (27.2%) without evidence of loosening. Conclusion. This study supports the use of UKA in medial compartment osteoarthritis with excellent long-term functional and radiological outcomes with an excellent 15-year survival rate. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):41–7


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 432 - 435
1 Apr 2018
Murray DW Parkinson RW

Unicompartmental knee arthroplasty (UKA) has numerous advantages over total knee arthroplasty (TKA) and one disadvantage, the higher revision rate. The best way to minimize the revision rate is for surgeons to use UKA for at least 20% of their knee arthroplasties. To achieve this, they need to learn and apply the appropriate indications and techniques. This would decrease the revision rate and increase the number of UKAs which were implanted, which would save money and patients would benefit from improved outcomes over their lifetime. Cite this article: Bone Joint J 2018;100-B:432–5


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1572 - 1578
1 Dec 2018
Middleton R Wilson HA Alvand A Abram SGF Bottomley N Jackson W Price A

Aims. Our unit was identified as a negative outlier in the national patient-reported outcome measures (PROMs) programme, which has significant funding implications. As a centre that carries out a high volume of unicompartmental knee arthroplasty (UKA), our objectives were: 1) to determine whether the PROMs programme included primary UKA when calculating the gain in Oxford Knee Score (OKS); and 2) to determine the impact of excluding primary UKA on calculated OKS gains for primary knee arthroplasty. Materials and Methods. National PROMs data from England (2012 to 2016) were analyzed. Inclusion of UKA cases in the national PROMs programme was determined using clinical codes. Local OKS gain was calculated for UKA and TKA and compared with the published PROMs results for 2012/13. Results. Use of the recommended codes for primary UKA excluded 99.6% of UKAs locally and 97% nationally from PROMs programme analysis. Inclusion of primary UKAs in PROMs analysis improved our OKS gain from 15.1 (below average) to 16.3 (above average) for 2012/13 for primary knee arthroplasty. Conclusion. Exclusion of UKA patients from the PROMs programme is a nationwide issue that potentially introduces bias when comparing OKS gain between centres. Where commissioning decisions are based on routinely collected data, it is imperative that the underlying methodology is appropriate to generate valid results


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 632 - 639
1 May 2017
Hamilton TW Pandit HG Maurer DG Ostlere SJ Jenkins C Mellon SJ Dodd CAF Murray DW

Aims. It is not clear whether anterior knee pain and osteoarthritis (OA) of the patellofemoral joint (PFJ) are contraindications to medial unicompartmental knee arthroplasty (UKA). Our aim was to investigate the long-term outcome of a consecutive series of patients, some of whom had anterior knee pain and PFJ OA managed with UKA. Patients and Methods. We assessed the ten-year functional outcomes and 15-year implant survival of 805 knees (677 patients) following medial mobile-bearing UKA. The intra-operative status of the PFJ was documented and, with the exception of bone loss with grooving to the lateral side, neither the clinical or radiological state of the PFJ nor the presence of anterior knee pain were considered a contraindication. The impact of radiographic findings and anterior knee pain was studied in a subgroup of 100 knees (91 patients). Results. There was no relationship between functional outcomes, at a mean of ten years, or 15-year implant survival, and pre-operative anterior knee pain, or the presence or degree of cartilage loss documented intra-operatively at the medial patella or trochlea, or radiographic evidence of OA in the medial side of the PFJ. In 6% of cases there was full thickness cartilage loss on the lateral side of the patella. In these cases, the overall ten-year function and 15-year survival was similar to those without cartilage loss; however they had slightly more difficulty with descending stairs. Radiographic signs of OA seen in the lateral part of the PFJ were not associated with a definite compromise in functional outcome or implant survival. Conclusion. Severe damage to the lateral side of the PFJ with bone loss and grooving remains a contraindication to mobile-bearing UKA. Less severe damage to the lateral side of the PFJ and damage to the medial side, however severe, does not compromise the overall function or survival, so should not be considered to be a contraindication. However, if a patient does have full thickness cartilage loss on the lateral side of the PFJ they may have a slight compromise in their ability to descend stairs. Pre-operative anterior knee pain also does not compromise the functional outcome or survival and should not be considered to be a contraindication. Cite this article: Bone Joint J 2017;99-B:632–9


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1620 - 1624
1 Dec 2016
Pailhé R Cognault J Massfelder J Sharma A Rouchy R Rubens-Duval B Saragaglia D

Aims. The role of high tibial osteotomy (HTO) is being questioned by the use of unicompartmental knee arthroplasty (UKA) in the treatment of medial compartment femorotibial osteoarthritis. Our aim was to compare the outcomes of revision HTO or UKA to a total knee arthroplasty (TKA) using computer-assisted surgery in matched groups of patients. Patients and Methods. We conducted a retrospective study to compare the clinical and radiological outcome of patients who underwent revision of a HTO to a TKA (group 1) with those who underwent revision of a medial UKA to a TKA (group 2). All revision procedures were performed using computer-assisted surgery. We extracted these groups of patients from our database. They were matched by age, gender, body mass index, follow-up and pre-operative functional score. The outcomes included the Knee Society Scores (KSS), radiological outcomes and the rate of further revision. Results. There were 20 knees in 20 patients in each group. The mean follow-up was 4.1 years (2 to 18.7). The mean total KSS at last follow-up was 185.7 (standard deviation (. sd. ) 5) in group 1 compared with 176.5 (. sd. 11) for group 2 (p = 0.003). The mean hip-knee-ankle angle was 180.2° (. sd. 3.2°) in group 1 and 179.0° (. sd. 2.2°) in group 2. No revision was required. Conclusion. We found that good functional and radiological outcomes followed revision of both HTO and UKA to TKA. Revision of HTO showed significantly better functional outcomes. These results need to be further investigated by a prospective randomised controlled trial involving a larger group of patients. Cite this article: Bone Joint J 2016;98-B:1620–4


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 43 - 47
1 Jan 2004
Ritter MA Faris PM Thong AE Davis KE Meding JB Berend ME

Interest in unicompartmental knee arthroplasty (UKA) for the treatment of medial compartment osteoarthritis has increased in recent years with apparent improvement in the long-term results. This is a result of improved surgical technique, patient selection, and implant design. In an effort further to improve patient selection we analysed the relationship between the pre-operative alignment of the knee and the anatomical findings at the time of surgery. We compared these findings with the indications for UKA. From 4021 total knee arthroplasties we compared intra-operative observations with the pre-operative clinical data in order to identify knees with isolated, medial, compartment changes, which would have been ideal candidates for UKA. We found that only 247 of the knees (6.1%) met anatomical qualifications for isolated, medial, unicompartmental osteoarthritis, and of these, only 168 (4.3%) met clinical standards ideal for UKA. Pre-operative alignment showed a significant relationship with patterns of disease. Logistic regression revealed a relationship between pre-operative alignment and intra-operative findings resembling a Gaussian distribution. Patients with a pre-operative varus alignment of 7° were slightly more likely to be selected for UKA. But the further the anatomical alignment in either direction varies from 7° of varus, the more unlikely it is for the knee to exhibit a disease pattern of isolated, medial, unicompartmental osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 351 - 355
1 Apr 2002
Ridgeway SR McAuley JP Ammeen DJ Engh GA

Many authors have recommended undercorrection of the deformity when carrying out unicompartmental knee arthroplasty (UKA). The isolated effect of alignment of the knee on the outcome of UKA has, however, received little attention. We reviewed 185 UKAs at a minimum of five years after surgery. They had been carried out by a single surgeon using metal-backed tibial components in the management of arthritis of the medial compartment. We measured the tibiofemoral angle (TFA) before and at four months after operation and at the most recent assessment. The amount of correction of the TFA and any subsequent loss were recorded. While adjusting for the effects of age, weight and gender of the patients and the type and thickness of the implants, the mean correction was significantly less for those with a Marmor rating of failure (6.8°) than for those rated excellent (9.2°). The mean correction was also significantly less for patients with a Marmor rating of failure (6.8°) than for those rated poor (11.1°). The mean correction for the UKAs which were revised (6.6°) was significantly less than for those not revised (9.1°). Additionally, revised UKAs had a significantly higher percentage (63%) of thinner tibial implants (< 8 mm) than the surviving UKAs (27%). These findings suggest that undercorrection of the TFA in UKA of the medial compartment should be avoided, particularly if a thin tibial polyethylene insert is used


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 114 - 120
1 Feb 2024
Khatri C Metcalfe A Wall P Underwood M Haddad FS Davis ET

Total hip and knee arthroplasty (THA, TKA) are largely successful procedures; however, both have variable outcomes, resulting in some patients being dissatisfied with the outcome. Surgeons are turning to technologies such as robotic-assisted surgery in an attempt to improve outcomes. Robust studies are needed to find out if these innovations are really benefitting patients. The Robotic Arthroplasty Clinical and Cost Effectiveness Randomised Controlled Trials (RACER) trials are multicentre, patient-blinded randomized controlled trials. The patients have primary osteoarthritis of the hip or knee. The operation is Mako-assisted THA or TKA and the control groups have operations using conventional instruments. The primary clinical outcome is the Forgotten Joint Score at 12 months, and there is a built-in analysis of cost-effectiveness. Secondary outcomes include early pain, the alignment of the components, and medium- to long-term outcomes. This annotation outlines the need to assess these technologies and discusses the design and challenges when conducting such trials, including surgical workflows, isolating the effect of the operation, blinding, and assessing the learning curve. Finally, the future of robotic surgery is discussed, including the need to contemporaneously introduce and evaluate such technologies.

Cite this article: Bone Joint J 2024;106-B(2):114–120.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1323 - 1328
1 Dec 2022
Cochrane NH Kim B Seyler TM Bolognesi MP Wellman SS Ryan SP

Aims

In the last decade, perioperative advancements have expanded the use of outpatient primary total knee arthroplasty (TKA). Despite this, there remains limited data on expedited discharge after revision TKA. This study compared 30-day readmissions and reoperations in patients undergoing revision TKA with a hospital stay greater or less than 24 hours. The authors hypothesized that expedited discharge in select patients would not be associated with increased 30-day readmissions and reoperations.

Methods

Aseptic revision TKAs in the National Surgical Quality Improvement Program database were reviewed from 2013 to 2020. TKAs were stratified by length of hospital stay (greater or less than 24 hours). Patient demographic details, medical comorbidities, American Society of Anesthesiologists (ASA) grade, operating time, components revised, 30-day readmissions, and reoperations were compared. Multivariate analysis evaluated predictors of discharge prior to 24 hours, 30-day readmission, and reoperation.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 916 - 923
1 Sep 2024
Fricka KB Wilson EJ Strait AV Ho H Hopper, Jr RH Hamilton WG Sershon RA

Aims

The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution.

Methods

Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6).


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 166 - 173
1 Feb 2024
Scott CEH Yapp LZ MacDonald DJ Howie CR Clement ND

Aims

The primary aim was to assess change in health-related quality of life (HRQoL) of patients as they waited from six to 12 months for a total hip (THA) or total or partial knee arthroplasty (KA). Secondary aims were to assess change in joint-specific function, mental health, quality of sleep, number living in a state worse than death (WTD), wellbeing, and patient satisfaction with their healthcare.

Methods

This prospective study included 142 patients awaiting a THA (mean age 66.7 years (SD 11.4); 71 female) and 214 patients awaiting KA (mean age 69.7 years (SD 8.7); 117 female). Patients completed questionnaires (EuroQol five-dimension health questionnaire (EQ-5D), Oxford Hip and Knee Scores (OHS/OKS), Pittsburgh Sleep Quality Index (PSQI), Hospital Anxiety and Depression Score (HADS), University of California, Los Angeles Activity Scale, wellbeing assessment, and satisfaction with their healthcare) at six and 12 months while awaiting surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 158 - 165
1 Feb 2024
Nasser AAHH Sidhu M Prakash R Mahmood A

Aims

Periprosthetic fractures (PPFs) around the knee are challenging injuries. This study aims to describe the characteristics of knee PPFs and the impact of patient demographics, fracture types, and management modalities on in-hospital mortality.

Methods

Using a multicentre study design, independent of registry data, we included adult patients sustaining a PPF around a knee arthroplasty between 1 January 2010 and 31 December 2019. Univariate, then multivariable, logistic regression analyses were performed to study the impact of patient, fracture, and treatment on mortality.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1074 - 1083
1 Oct 2024
Sørensen RR Timm S Rasmussen LE Brasen CL Varnum C

Aims

The influence of metabolic syndrome (MetS) on the outcome after hip and knee arthroplasty is debated. We aimed to investigate the change in patient-reported outcome measure (PROM) scores after hip and knee arthroplasty, comparing patients with and without MetS.

Methods

From 1 May 2017 to 30 November 2019, a prospective cohort of 2,586 patients undergoing elective unilateral hip and knee arthroplasty was established in Denmark. Data from national registries and a local database were used to determine the presence of MetS. Patients’ scores on Oxford Hip Score (OHS) or Oxford Knee Score (OKS), EuroQol five-dimension five-level questionnaire (EQ-5D-5L), University of California, Los Angeles (UCLA) Activity Scale, and Forgotten Joint Score (FJS) at baseline, three, 12, and 24 months after surgery were collected. Primary outcome was the difference between groups from baseline to 12 months in OHS and OKS. Secondary outcomes were scores of OHS and OKS at three and 24 months and EQ-5D-5L, UCLA Activity Scale, and FJS at three, 12, and 24 months after surgery. Generalized linear mixed model was applied, adjusting for age, sex, Charlson Comorbidity Index, and smoking to present marginal mean and associated 95% CIs.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 541 - 548
1 May 2022
Zhang J Ng N Scott CEH Blyth MJG Haddad FS Macpherson GJ Patton JT Clement ND

Aims

This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA).

Methods

Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta-­Analysis statement. Search terms included “robotic”, “unicompartmental”, “knee”, and “arthroplasty”. Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1261 - 1269
1 Jul 2021
Burger JA Zuiderbaan HA Sierevelt IN van Steenbergen L Nolte PA Pearle AD Kerkhoffs GMMJ

Aims

Uncemented mobile bearing designs in medial unicompartmental knee arthroplasty (UKA) have seen an increase over the last decade. However, there are a lack of large-scale studies comparing survivorship of these specific designs to commonly used cemented mobile and fixed bearing designs. The aim of this study was to evaluate the survivorship of these designs.

Methods

A total of 21,610 medial UKAs from 2007 to 2018 were selected from the Dutch Arthroplasty Register. Multivariate Cox regression analyses were used to compare uncemented mobile bearings with cemented mobile and fixed bearings. Adjustments were made for patient and surgical factors, with their interactions being considered. Reasons and type of revision in the first two years after surgery were assessed.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 338 - 346
1 Feb 2021
Khow YZ Liow MHL Lee M Chen JY Lo NN Yeo SJ

Aims

This study aimed to identify the tibial component and femoral component coronal angles (TCCAs and FCCAs), which concomitantly are associated with the best outcomes and survivorship in a cohort of fixed-bearing, cemented, medial unicompartmental knee arthroplasties (UKAs). We also investigated the potential two-way interactions between the TCCA and FCCA.

Methods

Prospectively collected registry data involving 264 UKAs from a single institution were analyzed. The TCCAs and FCCAs were measured on postoperative radiographs and absolute angles were analyzed. Clinical assessment at six months, two years, and ten years was undertaken using the Knee Society Knee score (KSKS) and Knee Society Function score (KSFS), the Oxford Knee Score (OKS), the 36-Item Short-Form Health Survey questionnaire (SF-36), and range of motion (ROM). Fulfilment of expectations and satisfaction was also recorded. Implant survivorship was reviewed at a mean follow-up of 14 years (12 to 16). Multivariate regression models included covariates, TCCA, FCCA, and two-way interactions between them. Partial residual graphs were generated to identify angles associated with the best outcomes. Kaplan-Meier analysis was used to compare implant survivorship between groups.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 126 - 130
1 Jun 2021
Chalmers BP Goytizolo E Mishu MD Westrich GH

Aims

Manipulation under anaesthesia (MUA) remains an effective intervention to address restricted range of motion (ROM) after total knee arthroplasty (TKA) and occurs in 2% to 3% of primary TKAs at our institution. Since there are few data on the outcomes of MUA with different anaesthetic methods, we sought to compare the outcomes of patients undergoing MUA with intravenous (IV) sedation and neuraxial anaesthesia.

Methods

We identified 548 MUAs after primary TKA (136 IV sedation, 412 neuraxial anaesthesia plus IV sedation) from March 2016 to July 2019. The mean age of this cohort was 62 years (35 to 88) with a mean body mass index of 31 kg/m2 (18 to 49). The mean time from primary TKA to MUA was 10.2 weeks (6.2 to 24.3). Pre-MUA ROM was similar between groups; overall mean pre-MUA extension was 4.2° (p = 0.452) and mean pre-MUA flexion was 77° (p = 0.372). We compared orthopaedic complications, visual analogue scale (VAS) pain scores, length of stay (LOS), and immediate and three-month follow-up knee ROM between these groups.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 838 - 847
1 Jul 2019
Robinson PG Clement ND Hamilton D Blyth MJG Haddad FS Patton JT

Aims

Robotic-assisted unicompartmental knee arthroplasty (UKA) promises accurate implant placement with the potential of improved survival and functional outcomes. The aim of this study was to present the current evidence for robotic-assisted UKA and describe the outcome in terms of implant positioning, range of movement (ROM), function and survival, and the types of robot and implants that are currently used.

Materials and Methods

A search of PubMed and Medline was performed in October 2018 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “knee”, and “surgery”. The criteria for inclusion was any study describing the use of robotic UKA and reporting implant positioning, ROM, function, and survival for clinical, cadaveric, or dry bone studies.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1511 - 1518
1 Nov 2020
Banger MS Johnston WD Razii N Doonan J Rowe PJ Jones BG MacLean AD Blyth MJG

Aims

The aim of this study was to compare robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) in order to determine the changes in the anatomy of the knee and alignment of the lower limb following surgery.

Methods

An analysis of 38 patients who underwent TKA and 32 who underwent bi-UKA was performed as a secondary study from a prospective, single-centre, randomized controlled trial. CT imaging was used to measure coronal, sagittal, and axial alignment of the knee preoperatively and at three months postoperatively to determine changes in anatomy that had occurred as a result of the surgery. The hip-knee-ankle angle (HKAA) was also measured to identify any differences between the two groups.


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 85 - 89
1 Jul 2020
Barrack TN Abu-Amer W Schwabe MT Adelani MA Clohisy JC Nunley RM Lawrie CM

Aims

Routine surveillance of primary hip and knee arthroplasties has traditionally been performed with office follow-up visits at one year postoperatively. The value of these visits is unclear. The present study aims to determine the utility and burden of routine clinical follow-up at one year after primary arthroplasty to patients and providers.

Methods

All patients (473) who underwent primary total hip (280), hip resurfacing (eight), total knee (179), and unicompartmental knee arthroplasty (six) over a nine-month period at a single institution were identified from an institutional registry. Patients were prompted to attend their routine one-year postoperative visit by a single telephone reminder. Patients and surgeons were given questionnaires at the one-year postoperative visit, defined as a clinical encounter occurring at nine to 15 months from the date of surgery, regarding value of the visit.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 401 - 402
1 Apr 2020
Chang JS Haddad FS


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1183 - 1193
14 Sep 2020
Anis HK Strnad GJ Klika AK Zajichek A Spindler KP Barsoum WK Higuera CA Piuzzi NS

Aims

The purpose of this study was to develop a personalized outcome prediction tool, to be used with knee arthroplasty patients, that predicts outcomes (lengths of stay (LOS), 90 day readmission, and one-year patient-reported outcome measures (PROMs) on an individual basis and allows for dynamic modifiable risk factors.

Methods

Data were prospectively collected on all patients who underwent total or unicompartmental knee arthroplasty at a between July 2015 and June 2018. Cohort 1 (n = 5,958) was utilized to develop models for LOS and 90 day readmission. Cohort 2 (n = 2,391, surgery date 2015 to 2017) was utilized to develop models for one-year improvements in Knee Injury and Osteoarthritis Outcome Score (KOOS) pain score, KOOS function score, and KOOS quality of life (QOL) score. Model accuracies within the imputed data set were assessed through cross-validation with root mean square errors (RMSEs) and mean absolute errors (MAEs) for the LOS and PROMs models, and the index of prediction accuracy (IPA), and area under the curve (AUC) for the readmission models. Model accuracies in new patient data sets were assessed with AUC.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1177 - 1178
1 Oct 2019
Troelsen A Haddad FS


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 301 - 309
1 Mar 2020
Keenan OJF Holland G Maempel JF Keating JF Scott CEH

Aims

Although knee osteoarthritis (OA) is diagnosed and monitored radiologically, actual full-thickness cartilage loss (FTCL) has rarely been correlated with radiological classification. This study aims to analyze which classification system correlates best with FTCL and to assess their reliability.

Methods

A prospective study of 300 consecutive patients undergoing unilateral total knee arthroplasty (TKA) for OA (mean age 69 years (44 to 91; standard deviation (SD) 9.5), 178 (59%) female). Two blinded examiners independently graded preoperative radiographs using five common systems: Kellgren-Lawrence (KL); International Knee Documentation Committee (IKDC); Fairbank; Brandt; and Ahlbäck. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC). Intraoperatively, anterior cruciate ligament (ACL) status and the presence of FTCL in 16 regions of interest were recorded. Radiological classification and FTCL were correlated using the Spearman correlation coefficient.


Aims

The aim is to assess the cost-effectiveness of patellofemoral arthroplasty (PFA) in comparison with total knee arthroplasty (TKA) for the treatment of isolated patellofemoral osteoarthritis (OA) based on prospectively collected data on health outcomes and resource use from a blinded, randomized, clinical trial.

Methods

A total of 100 patients with isolated patellofemoral osteoarthritis were randomized to receive either PFA or TKA by experienced knee surgeons trained in using both implants. Patients completed patient-reported outcomes including EuroQol five-dimension questionnaire (EQ-5D) and 6-Item Short-Form Health Survey questionnaire (SF-6D) before the procedure. The scores were completed again after six weeks, three, six, and nine months, and again after one- and two-year post-surgery and yearly henceforth. Time-weighted outcome measures were constructed. Cost data were obtained from clinical registrations and patient-reported questionnaires. Incremental gain in health outcomes (quality-adjusted life-years (QALYs)) and incremental costs were compared for the two groups of patients. Net monetary benefit was calculated assuming a threshold value of €10,000, €35,000, and €50,000 per QALY and used to test the statistical uncertainty and central assumptions about outcomes and costs.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1356 - 1361
1 Nov 2019
Chalmers BP Mehrotra KG Sierra RJ Pagnano MW Taunton MJ Abdel MP

Aims

Knee osteonecrosis in advanced stages may lead to joint degeneration. Total knee arthroplasty (TKA) for osteonecrosis has traditionally been associated with suboptimal results. We analyzed outcomes of contemporary TKAs for osteonecrosis, with particular emphasis on: survivorship free from aseptic loosening, any revision, and any reoperation plus the clinical outcomes, complications, and radiological results.

Patients and Methods

In total, 156 patients undergoing 167 primary TKAs performed for osteonecrosis between 2004 and 2014 at a single institution were reviewed. The mean age at index TKA was 61 years (14 to 93) and the mean body mass index (BMI) was 30 kg/m2 (18 to 51) The mean follow-up was six years (2 to 12). A total of 110 TKAs (66%) were performed for primary osteonecrosis and 57 TKAs (34%) for secondary osteonecrosis. Overall, 15 TKAs (9%) had tibial stems, while 12 TKAs (7%) had femoral stems. Posterior-stabilized designs were used in 147 TKAs (88%) of TKAs. Bivariate Cox regression analysis was conducted to identify risk factors for revision and reoperation.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1033 - 1042
1 Aug 2018
Kayani B Konan S Pietrzak JRT Huq SS Tahmassebi J Haddad FS

Aims

The primary aim of this study was to determine the surgical team’s learning curve for introducing robotic-arm assisted unicompartmental knee arthroplasty (UKA) into routine surgical practice. The secondary objective was to compare accuracy of implant positioning in conventional jig-based UKA versus robotic-arm assisted UKA.

Patients and Methods

This prospective single-surgeon cohort study included 60 consecutive conventional jig-based UKAs compared with 60 consecutive robotic-arm assisted UKAs for medial compartment knee osteoarthritis. Patients undergoing conventional UKA and robotic-arm assisted UKA were well-matched for baseline characteristics including a mean age of 65.5 years (sd 6.8) vs 64.1 years (sd 8.7), (p = 0.31); a mean body mass index of 27.2 kg.m2 (sd 2.7) vs 28.1 kg.m2 (sd 4.5), (p = 0.25); and gender (27 males: 33 females vs 26 males: 34 females, p = 0.85). Surrogate measures of the learning curve were prospectively collected. These included operative times, the Spielberger State-Trait Anxiety Inventory (STAI) questionnaire to assess preoperative stress levels amongst the surgical team, accuracy of implant positioning, limb alignment, and postoperative complications.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 922 - 928
1 Aug 2019
Garner A van Arkel RJ Cobb J

Aims

There has been a recent resurgence in interest in combined partial knee arthroplasty (PKA) as an alternative to total knee arthroplasty (TKA). The varied terminology used to describe these procedures leads to confusion and ambiguity in communication between surgeons, allied health professionals, and patients. A standardized classification system is required for patient safety, accurate clinical record-keeping, clear communication, correct coding for appropriate remuneration, and joint registry data collection.

Materials and Methods

An advanced PubMed search was conducted, using medical subject headings (MeSH) to identify terms and abbreviations used to describe knee arthroplasty procedures. The search related to TKA, unicompartmental (UKA), patellofemoral (PFA), and combined PKA procedures. Surveys were conducted of orthopaedic surgeons, trainees, and biomechanical engineers, who were asked which of the descriptive terms and abbreviations identified from the literature search they found most intuitive and appropriate to describe each procedure. The results were used to determine a popular consensus.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 22 - 23
1 Jan 2019
Kayani B Konan S Tahmassebi J Rowan FE Haddad FS


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 915 - 921
1 Aug 2019
Beckers L Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims

Altered alignment and biomechanics are thought to contribute to the progression of osteoarthritis (OA) in the native compartments after medial unicompartmental knee arthroplasty (UKA). The aim of this study was to evaluate the bone activity and remodelling in the lateral tibiofemoral and patellofemoral compartment after medial mobile-bearing UKA.

Patients and Methods

In total, 24 patients (nine female, 15 male) with 25 medial Oxford UKAs (13 left, 12 right) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively and at one and two years postoperatively, along with standard radiographs and clinical outcome scores. The mean patient age was 62 years (40 to 78) and the mean body mass index (BMI) was 29.7 kg/m2 (23.6 to 42.2). Mean osteoblastic activity was evaluated using a tracer localization scheme with volumes of interest (VOIs). Normalized mean tracer values were calculated as the ratio between the mean tracer activity in a VOI and background activity in the femoral diaphysis.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 793 - 801
1 Jun 2015
Liddle AD Pandit H Judge A Murray DW

Whether to use total or unicompartmental knee replacement (TKA/UKA) for end-stage knee osteoarthritis remains controversial. Although UKA results in a faster recovery, lower rates of morbidity and mortality and fewer complications, the long-term revision rate is substantially higher than that for TKA. The effect of each intervention on patient-reported outcome remains unclear. The aim of this study was to determine whether six-month patient-reported outcome measures (PROMs) are better in patients after TKA or UKA, using data from a large national joint registry (NJR).

We carried out a propensity score-matched cohort study which compared six-month PROMs after TKA and UKA in patients enrolled in the NJR for England and Wales, and the English national PROM collection programme. A total of 3519 UKA patients were matched to 10 557 TKAs.

The mean six-month PROMs favoured UKA: the Oxford Knee Score was 37.7 (95% confidence interval (CI) 37.4 to 38.0) for UKA and 36.1 (95% CI 35.9 to 36.3) for TKA; the mean EuroQol EQ-5D index was 0.772 (95% CI 0.764 to 0.780) for UKA and 0.751 (95% CI 0.747 to 0.756) for TKA. UKA patients were more likely to achieve excellent results (odds ratio (OR) 1.59, 95% CI 1.47 to 1.72, p < 0.001) and to be highly satisfied (OR 1.27, 95% CI 1.17 to 1.39, p <  0.001), and were less likely to report complications than those who had undergone TKA.

UKA gives better early patient-reported outcomes than TKA; these differences are most marked for the very best outcomes. Complications and readmission are more likely after TKA. Although the data presented reflect the short-term outcome, they suggest that the high revision rate for UKA may not be because of poorer clinical outcomes. These factors should inform decision-making in patients eligible for either procedure.

Cite this article: Bone Joint J 2015;97-B:793–801.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 450 - 454
1 Apr 2018
Chalmers BP Mehrotra KG Sierra RJ Pagnano MW Taunton MJ Abdel MP

Aims

Primary (or spontaneous) and secondary osteonecrosis of the knee can lead to severe joint degeneration, for which either total or unicompartmental arthroplasty may be considered. However, there are limited studies analyzing outcomes of unicompartmental knee arthroplasties (UKAs) for osteonecrosis involving an isolated compartment of the knee. The aims of this study were to analyze outcomes of UKAs for osteonecrosis with specific focus on 1) survivorship free of any revision or reoperation, 2) risk factors for failure, 3) clinical outcomes, and 4) complications.

Patients and Methods

A total of 45 patients underwent 46 UKAs for knee osteonecrosis between 2002 and 2014 at our institution (The Mayo Clinic, Rochester, Minnesota). Twenty patients (44%) were female; the mean age of the patients was 66 years, and mean body mass index (BMI) was 31 kg/m2. Of the 46 UKAs, 44 (96%) were medial UKAs, and 35 (76%) were fixed-bearing design. Mean mechanical axis postoperatively was 1.5° varus (0° to 5° varus); 41 UKAs (89%) were performed for primary osteonecrosis. Mean follow-up was five years (2 to 12)


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1329 - 1334
1 Oct 2017
Lim JBT Chong HC Pang HN Tay KJD Chia SL Lo NN Yeo SJ

Aims

Little is known about the relative outcomes of revision of unicompartmental knee arthroplasty (UKA) and high tibial osteotomy (HTO) to total knee arthroplasty (TKA). The aim of this study is to compare the outcomes of revision surgery for the two procedures in terms of complications, re-revision and patient-reported outcome measures (PROMs) at a minimum of two years follow-up.

Patients and Methods

This study was a retrospective review of data from an institutional arthroplasty registry for cases performed between 2001 and 2014. A total of 292 patients were identified, of which 217 had a revision of HTO to TKA, and 75 had revision of UKA to TKA. While mean follow-up was longer for the HTO group compared with the UKA group, patient demographics (age, body mass index and Charlson co-morbidity index) and PROMs (Short Form-36, Oxford Knee Score, Knee Society Score, both objective and functional) were similar in the two groups prior to revision surgery. Outcomes included the rate of complications and re-operation, PROMS and patient-reported satisfaction at six months and two years post-operatively. We also compared the duration of surgery and the need for revision implants in the two groups.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 623 - 631
1 May 2017
Blaney J Harty H Doran E O’Brien S Hill J Dobie I Beverland D

Aims

Our aim was to examine the clinical and radiographic outcomes in 257 consecutive Oxford unicompartmental knee arthroplasties (OUKAs) (238 patients), five years post-operatively.

Patients and Methods

A retrospective evaluation was undertaken of patients treated between April 2008 and October 2010 in a regional centre by two non-designing surgeons with no previous experience of UKAs. The Oxford Knee Scores (OKSs) were recorded and fluoroscopically aligned radiographs were assessed post-operatively at one and five years.


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 475 - 482
1 Apr 2017
Hamilton TW Pandit HG Inabathula A Ostlere SJ Jenkins C Mellon SJ Dodd CAF Murray DW

Aims

While medial unicompartmental knee arthroplasty (UKA) is indicated for patients with full-thickness cartilage loss, it is occasionally used to treat those with partial-thickness loss. The aim of this study was to investigate the five-year outcomes in a consecutive series of UKAs used in patients with partial thickness cartilage loss in the medial compartment of the knee.

Patients and Methods

Between 2002 and 2014, 94 consecutive UKAs were undertaken in 90 patients with partial thickness cartilage loss and followed up independently for a mean of six years (1 to 13). These patients had partial thickness cartilage loss either on both femur and tibia (13 knees), or on either the femur or the tibia, with full thickness loss on the other surface of the joint (18 and 63 knees respectively). Using propensity score analysis, these patients were matched 1:2 based on age, gender and pre-operative Oxford Knee Score (OKS) with knees with full thickness loss on both the femur and tibia. The functional outcomes, implant survival and incidence of re-operations were assessed at one, two and five years post-operatively. A subgroup of 36 knees in 36 patients with partial thickness cartilage loss, who had pre-operative MRI scans, was assessed to identify whether there were any factors identified on MRI that predicted the outcome.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 11 - 15
1 Oct 2016
Konan S Haddad FS

Aims

Medial unicompartmental knee arthroplasty (UKA) is associated with successful outcomes in carefully selected patient cohorts. We hypothesised that severity and location of patellofemoral cartilage lesions significantly influences functional outcome after Oxford medial compartmental knee arthroplasty.

Patients and Methods

We reviewed 100 consecutive UKAs at minimum eight-year follow-up (96 to 132). A single surgeon performed all procedures. Patients were selected based on clinical and plain radiographic assessment. All patients had end-stage medial compartment osteoarthritis (OA) with sparing of the lateral compartment and intact anterior cruciate ligaments. None of the patients had end-stage patellofemoral OA, but patients with anterior knee pain or partial thickness chondral loss were not excluded. There were 57 male and 43 female patients. The mean age at surgery was 69 years (41 to 82). At surgery the joint was carefully inspected for patellofemoral chondral loss and this was documented based on severity of cartilage loss (0 to 4 Outerbridge grading) and topographic location (medial, lateral, central, and superior or inferior). Functional scores collected included Oxford Knee Score (OKS), patient satisfaction scale and University College Hospital (UCH) knee score. Intraclass correlation was used to compare chondral damage to outcomes.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 22 - 27
1 Oct 2016
Bottomley N Jones LD Rout R Alvand A Rombach I Evans T Jackson WFM Beard DJ Price AJ

Aims

The aim of this to study was to compare the previously unreported long-term survival outcome of the Oxford medial unicompartmental knee arthroplasty (UKA) performed by trainee surgeons and consultants.

Patients and Methods

We therefore identified a previously unreported cohort of 1084 knees in 947 patients who had a UKA inserted for anteromedial knee arthritis by consultants and surgeons in training, at a tertiary arthroplasty centre and performed survival analysis on the group with revision as the endpoint.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 3 - 10
1 Oct 2016
Hamilton TW Pandit HG Lombardi AV Adams JB Oosthuizen CR Clavé A Dodd CAF Berend KR Murray DW

Aims

An evidence-based radiographic Decision Aid for meniscal-bearing unicompartmental knee arthroplasty (UKA) has been developed and this study investigates its performance at an independent centre.

Patients and Methods

Pre-operative radiographs, including stress views, from a consecutive cohort of 550 knees undergoing arthroplasty (UKA or total knee arthroplasty; TKA) by a single-surgeon were assessed. Suitability for UKA was determined using the Decision Aid, with the assessor blinded to treatment received, and compared with actual treatment received, which was determined by an experienced UKA surgeon based on history, examination, radiographic assessment including stress radiographs, and intra-operative assessment in line with the recommended indications as described in the literature.


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 3 - 8
1 Oct 2015
Murray DW Liddle AD Dodd CAF Pandit H

There is a large amount of evidence available about the relative merits of unicompartmental and total knee arthroplasty (UKA and TKA). Based on the same evidence, different people draw different conclusions and as a result, there is great variability in the usage of UKA.

The revision rate of UKA is much higher than TKA and so some surgeons conclude that UKA should not be performed. Other surgeons believe that the main reason for the high revision rate is that UKA is easy to revise and, therefore, the threshold for revision is low. They also believe that UKA has many advantages over TKA such as a faster recovery, lower morbidity and mortality and better function. They therefore conclude that UKA should be undertaken whenever appropriate.

The solution to this argument is to minimise the revision rate of UKA, thereby addressing the main disadvantage of UKA. The evidence suggests that this will be achieved if surgeons use UKA for at least 20% of their knee arthroplasties and use implants that are appropriate for these broad indications.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):3–8.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 786 - 792
1 Jun 2015
Hutt JRB Farhadnia P Massé V Lavigne M Vendittoli P

This randomised trial evaluated the outcome of a single design of unicompartmental arthroplasty of the knee (UKA) with either a cemented all-polyethylene or a metal-backed modular tibial component. A total of 63 knees in 45 patients (17 male, 28 female) were included, 27 in the all-polyethylene group and 36 in the metal-backed group. The mean age was 57.9 years (39.6 to 76.9). At a mean follow-up of 6.4 years (5 to 9.9), 11 all-polyethylene components (41%) were revised (at a mean of 5.8 years; 1.4 to 8.0) post-operatively and two metal-backed components were revised (at one and five years). One revision in both groups was for unexplained pain, one in the metal-backed group was for progression of osteoarthritis. The others in the all-polyethylene group were for aseptic loosening. The survivorship at seven years calculated by the Kaplan–Meier method for the all-polyethylene group was 56.5% (95% CI 31.9 to 75.2, number at risk 7) and for the metal-backed group was 93.8% (95% CI 77.3 to 98.4, number at risk 16) This difference was statistically significant (p <  0.001). At the most recent follow-up, significantly better mean Western Ontario and McMaster Universities Arthritis Index Scores were found in the all-polyethylene group (13.4 vs 23.0, p = 0.03) but there was no difference in the mean Knee injury and Osteoarthritis Outcome scores (68.8; 41.4 to 99.0 vs 62.6; 24.0 to 100.0), p = 0.36). There were no significant differences for range of movement (p = 0.36) or satisfaction (p = 0.23).

This randomised study demonstrates that all-polyethylene components in this design of fixed bearing UKA had unsatisfactory results with significantly higher rates of failure before ten years compared with the metal-back components.

Cite this article: Bone Joint J 2015;97-B:786–92.


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 9 - 15
1 Oct 2015
Parratte S Ollivier M Lunebourg A Abdel MP Argenson J

Partial knee arthroplasty (PKA), either medial or lateral unicompartmental knee artroplasty (UKA) or patellofemoral arthroplasty (PFA) are a good option in suitable patients and have the advantages of reduced operative trauma, preservation of both cruciate ligaments and bone stock, and restoration of normal kinematics within the knee joint. However, questions remain concerning long-term survival. The goal of this review article was to present the long-term results of medial and lateral UKA, PFA and combined compartmental arthroplasty for multicompartmental disease. Medium- and long-term studies suggest reasonable outcomes at ten years with survival greater than 95% in UKA performed for medial osteoarthritis or osteonecrosis, and similarly for lateral UKA, particularly when fixed-bearing implants are used. Disappointing long-term outcomes have been observed with the first generation of patellofemoral implants, as well as early Bi-Uni (ie, combined medial and lateral UKA) or Bicompartmental (combined UKA and PFA) implants due to design and fixation issues. Promising short- and med-term results with the newer generations of PFAs and bicompartmental arthroplasties will require long-term confirmation.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):9–15.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1358 - 1363
1 Oct 2015
Hooper N Snell D Hooper G Maxwell R Frampton C

This study reports on the first 150 consecutive Oxford cementless unicompartmental knee arthroplasties (UKA) performed in an independent centre (126 patients). All eligible patients had functional scores (Oxford knee score and high activity arthroplasty score) recorded pre-operatively and at two- and five-years of follow-up. Fluoroscopically aligned radiographs were taken at five years and analysed for any evidence of radiolucent lines (RLLs), subsidence or loosening. The mean age of the cohort was 63.6 years (39 to 86) with 81 (53.1%) males. Excellent functional scores were maintained at five years and there were no progressive RLLs demonstrated on radiographs. Two patients underwent revision to a total knee arthroplasty giving a revision rate of 0.23/100 (95% confidence interval 0.03 to 0.84) component years with overall component survivorship of 98.7% at five years. There were a further four patients who underwent further surgery on the same knee, two underwent bearing exchanges for dislocation and two underwent lateral UKAs for disease progression. This was a marked improvement from other UKAs reported in New Zealand Joint Registry data and supports the designing centre’s early results.

Cite this article: Bone Joint J 2015;97-B:1358–63.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1493 - 1499
1 Nov 2015
Pandit H Hamilton TW Jenkins C Mellon SJ Dodd CAF Murray DW

This prospective study reports the 15-year survival and ten-year functional outcome of a consecutive series of 1000 minimally invasive Phase 3 Oxford medial UKAs (818 patients, 393 men, 48%, 425 women, 52%, mean age 66 years; 32 to 88). These were implanted by two surgeons involved with the design of the prosthesis to treat anteromedial osteoarthritis and spontaneous osteonecrosis of the knee, which are recommended indications. Patients were prospectively identified and followed up independently for a mean of 10.3 years (5.3 to 16.6).

At ten years, the mean Oxford Knee Score was 40 (standard deviation (sd) 9; 2 to 48): 79% of knees (349) had an excellent or good outcome. There were 52 implant-related re-operations at a mean of 5.5 years (0.2 to 14.7). The most common reasons for re-operation were arthritis in the lateral compartment (2.5%, 25 knees), bearing dislocation (0.7%, seven knees) and unexplained pain (0.7%, seven knees). When all implant-related re-operations were considered as failures, the ten-year rate of survival was 94% (95% confidence interval (CI) 92 to 96) and the 15-year survival rate 91% (CI 83 to 98). When failure of the implant was the endpoint the 15-year survival was 99% (CI 96 to 100).

This is the only large series of minimally invasive UKAs with 15-year survival data. The results support the continued use of minimally invasive UKA for the recommended indications.

Cite this article: Bone Joint J 2015;97-B:1493–99.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 292 - 299
1 Mar 2015
Karthik K Colegate-Stone T Dasgupta P Tavakkolizadeh A Sinha J

The use of robots in orthopaedic surgery is an emerging field that is gaining momentum. It has the potential for significant improvements in surgical planning, accuracy of component implantation and patient safety. Advocates of robot-assisted systems describe better patient outcomes through improved pre-operative planning and enhanced execution of surgery. However, costs, limited availability, a lack of evidence regarding the efficiency and safety of such systems and an absence of long-term high-impact studies have restricted the widespread implementation of these systems. We have reviewed the literature on the efficacy, safety and current understanding of the use of robotics in orthopaedics.

Cite this article: Bone Joint J 2015; 97-B:292–9.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 185 - 191
1 Feb 2015
Kendrick BJL Kaptein BL Valstar ER Gill HS Jackson WFM Dodd CAF Price AJ Murray DW

The most common reasons for revision of unicompartmental knee arthroplasty (UKA) are loosening and pain. Cementless components may reduce the revision rate. The aim of this study was to compare the fixation and clinical outcome of cementless and cemented Oxford UKAs.

A total of 43 patients were randomised to receive either a cemented or a cementless Oxford UKA and were followed for two years with radiostereometric analysis (RSA), radiographs aligned with the bone–implant interfaces and clinical scores.

The femoral components migrated significantly during the first year (mean 0.2 mm) but not during the second. There was no significant difference in the extent of migration between cemented and cementless femoral components in either the first or the second year. In the first year the cementless tibial components subsided significantly more than the cemented components (mean 0.28 mm (sd 0.17) vs. 0.09 mm (sd 0.19 mm)). In the second year, although there was a small amount of subsidence (mean 0.05 mm) there was no significant difference (p = 0.92) between cemented and cementless tibial components. There were no femoral radiolucencies. Tibial radiolucencies were narrow (< 1 mm) and were significantly (p = 0.02) less common with cementless (6 of 21) than cemented (13 of 21) components at two years. There were no complete radiolucencies with cementless components, whereas five of 21 (24%) cemented components had complete radiolucencies. The clinical scores at two years were not significantly different (p = 0.20).

As second-year migration is predictive of subsequent loosening, and as radiolucency is suggestive of reduced implant–bone contact, these data suggest that fixation of the cementless components is at least as good as, if not better than, that of cemented devices.

Cite this article: Bone Joint J 2015; 97-B:185–91.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1488 - 1492
1 Nov 2005
Price AJ Dodd CAF Svard UGC Murray DW

We present a comparison of the results of the Oxford unicompartmental knee arthroplasty in patients younger and older than 60 years of age. The ten-year all-cause survival of the < 60 years of age group (52) was 91% (95% confidence interval (CI) 12), while in the ≥ 60 years of age group (512), the figure was 96% (95% CI 3). For the younger group, the mean Hospital for Special Surgery score at ten-year follow-up (n = 21) was 94 of 100, compared with a mean of 86 of 100 for the older group (n = 135). The results show that the Oxford unicompartmental arthroplasty can achieve ten-year results that are comparable to total knee arthroplasty in patients < 60 years of age. We conclude that for patients aged over 50, age should not be considered a contraindication for this procedure.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 188 - 197
1 Feb 2006
Cobb J Henckel J Gomes P Harris S Jakopec M Rodriguez F Barrett A Davies B

We performed a prospective, randomised controlled trial of unicompartmental knee arthroplasty comparing the performance of the Acrobot system with conventional surgery. A total of 27 patients (28 knees) awaiting unicompartmental knee arthroplasty were randomly allocated to have the operation performed conventionally or with the assistance of the Acrobot. The primary outcome measurement was the angle of tibiofemoral alignment in the coronal plane, measured by CT. Other secondary parameters were evaluated and are reported.

All of the Acrobot group had tibiofemoral alignment in the coronal plane within 2° of the planned position, while only 40% of the conventional group achieved this level of accuracy. While the operations took longer, no adverse effects were noted, and there was a trend towards improvement in performance with increasing accuracy based on the Western Ontario and McMaster Universities Osteoarthritis Index and American Knee Society scores at six weeks and three months. The Acrobot device allows the surgeon to reproduce a pre-operative plan more reliably than is possible using conventional techniques which may have clinical advantages.