Advertisement for orthosearch.org.uk
Results 1 - 100 of 399
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 787 - 792
1 Jun 2012
Thomsen MG Husted H Bencke J Curtis D Holm G Troelsen A

The purpose of this study was to investigate whether a gender-specific high-flexion posterior-stabilised (PS) total knee replacement (TKR) would offer advantages over a high-flex PS TKR regarding range of movement (ROM), ‘feel’ of the knee, pain and satisfaction, as well as during activity. A total of 24 female patients with bilateral osteoarthritis entered this prospective, blind randomised trial in which they received a high-flex PS TKR in one knee and a gender-specific high-flexion PS TKR in the other knee. At follow-up, patients were assessed clinically measuring ROM, and questioned about pain, satisfaction and daily ‘feel’ of each knee. Patients underwent gait analysis pre-operatively and at one year, which yielded kinematic, kinetic and temporospatial parameters indicative of knee function during gait. At final follow-up we found no statistically significant differences in ROM (p = 0.82). The median pain score was 0 (0 to 8) in both groups (p = 0.95). The median satisfaction score was 9 (4 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0.98). The median ‘feel’ score was 9 (3 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0.66). Gait analysis showed no statistically significant differences between the two prosthetic designs in any kinematic, kinetic or temporospatial parameters. Both designs produced good clinical results with significant improvements in several gait parameters without evidence of any advantage in the gender-specific design


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1284 - 1292
1 Nov 2024
Moroder P Poltaretskyi S Raiss P Denard PJ Werner BC Erickson BJ Griffin JW Metcalfe N Siegert P

Aims. The objective of this study was to compare simulated range of motion (ROM) for reverse total shoulder arthroplasty (rTSA) with and without adjustment for scapulothoracic orientation in a global reference system. We hypothesized that values for simulated ROM in preoperative planning software with and without adjustment for scapulothoracic orientation would be significantly different. Methods. A statistical shape model of the entire humerus and scapula was fitted into ten shoulder CT scans randomly selected from 162 patients who underwent rTSA. Six shoulder surgeons independently planned a rTSA in each model using prototype development software with the ability to adjust for scapulothoracic orientation, the starting position of the humerus, as well as kinematic planes in a global reference system simulating previously described posture types A, B, and C. ROM with and without posture adjustment was calculated and compared in all movement planes. Results. All movement planes showed significant differences when comparing protocols with and without adjustment for posture. The largest mean difference was seen in external rotation, being 62° (SD 16°) without adjustment compared to 25° (SD 9°) with posture adjustment (p < 0.001), with the highest mean difference being 49° (SD 15°) in type C. Mean extension was 57° (SD 18°) without adjustment versus 24° (SD 11°) with adjustment (p < 0.001) and the highest mean difference of 47° (SD 18°) in type C. Mean abducted internal rotation was 69° (SD 11°) without adjustment versus 31° (SD 6°) with posture adjustment (p < 0.001), showing the highest mean difference of 51° (SD 11°) in type C. Conclusion. The present study demonstrates that accounting for scapulothoracic orientation has a significant impact on simulated ROM for rTSA in all motion planes, specifically rendering vastly lower values for external rotation, extension, and high internal rotation. The substantial differences observed in this study warrant a critical re-evaluation of all previously published studies that examined component choice and placement for optimized ROM in rTSA using conventional preoperative planning software. Cite this article: Bone Joint J 2024;106-B(11):1284–1292


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 366 - 372
1 Feb 2021
Sun Z Li J Luo G Wang F Hu Y Fan C

Aims. This study aimed to determine the minimal detectable change (MDC), minimal clinically important difference (MCID), and substantial clinical benefit (SCB) under distribution- and anchor-based methods for the Mayo Elbow Performance Index (MEPI) and range of movement (ROM) after open elbow arthrolysis (OEA). We also assessed the proportion of patients who achieved MCID and SCB; and identified the factors associated with achieving MCID. Methods. A cohort of 265 patients treated by OEA were included. The MEPI and ROM were evaluated at baseline and at two-year follow-up. Distribution-based MDC was calculated with confidence intervals (CIs) reflecting 80% (MDC 80), 90% (MDC 90), and 95% (MDC 95) certainty, and MCID with changes from baseline to follow-up. Anchor-based MCID (anchored to somewhat satisfied) and SCB (very satisfied) were calculated using a five-level Likert satisfaction scale. Multivariate logistic regression of factors affecting MCID achievement was performed. Results. The MDC increased substantially based on selected CIs (MDC 80, MDC 90, and MDC 95), ranging from 5.0 to 7.6 points for the MEPI, and from 8.2° to 12.5° for ROM. The MCID of the MEPI were 8.3 points under distribution-based and 12.2 points under anchor-based methods; distribution- and anchor-based MCID of ROM were 14.1° and 25.0°. The SCB of the MEPI and ROM were 17.3 points and 43.4°, respectively. The proportion of the patients who attained anchor-based MCID for the MEPI and ROM were 74.0% and 94.7%, respectively; furthermore, 64.2% and 86.8% attained SCB. Non-dominant arm (p = 0.022), higher preoperative MEPI rating (p < 0.001), and postoperative visual analogue scale pain score (p < 0.001) were independent predictors of not achieving MCID for the MEPI, while atraumatic causes (p = 0.040) and higher preoperative ROM (p = 0.005) were independent risk factors for ROM. Conclusion. In patients undergoing OEA, the MCID for the increased MEPI is 12.2 points and 25° increased ROM. The SCB is 17.3 points and 43.3°, respectively. Future studies using the MEPI and ROM to assess OEA outcomes should report not only statistical significance but also clinical importance. Cite this article: Bone Joint J 2021;103-B(2):366–372


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 559 - 566
1 May 2022
Burden EG Batten T Smith C Evans JP

Aims. Arthroplasty is being increasingly used for the management of distal humeral fractures (DHFs) in elderly patients. Arthroplasty options include total elbow arthroplasty (TEA) and hemiarthroplasty (HA); both have unique complications and there is not yet a consensus on which implant is superior. This systematic review asked: in patients aged over 65 years with unreconstructable DHFs, what differences are there in outcomes, as measured by patient-reported outcome measures (PROMs), range of motion (ROM), and complications, between distal humeral HA and TEA?. Methods. A systematic review of the literature was performed via a search of MEDLINE and Embase. Two reviewers extracted data on PROMs, ROM, and complications. PROMs and ROM results were reported descriptively and a meta-analysis of complications was conducted. Quality of methodology was assessed using Wylde’s non-summative four-point system. The study was registered with PROSPERO (CRD42021228329). Results. A total of 29 studies met the inclusion and exclusion criteria. The mean Disabilities of the Arm, Shoulder and Hand questionnaire (DASH) score was 19.6 (SD 7.5) for HA and 38 (SD 11.9) for TEA and the mean abbreviated version of DASH was 17.2 (SD 13.2) for HA and 24.9 (SD 4.8) for TEA. The Mayo Elbow Performance Score was the most commonly reported PROM across included studies, with a mean of 87 (SD 5.3) in HA and 88.3 (SD 5) in TEA. High complication rates were seen in both HA (22% (95% confidence interval (CI) 5 to 44)) and TEA (21% (95% CI 13 to 30), but no statistically significant difference identified. Conclusion. This systematic review has indicated PROMs and ROM mostly favouring HA, but with a similarly high complication rate in the two procedures. However, due to the small sample size and heterogeneity between studies, strength of evidence for these findings is low. We propose further research in the form of a national randomized controlled trial. Cite this article: Bone Joint J 2022;104-B(5):559–566


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims. Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE. Methods. This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates. Results. Compared with non-stiff aTSAs, stiff aTSAs had poorer passive FE and active external rotation (ER), whereas there were no significant postoperative differences between stiff rTSAs and non-stiff rTSAs. There were no significant differences in preoperative function when comparing stiff aTSAs with stiff rTSAs. However, stiff rTSAs had significantly greater postoperative active and passive FE (p = 0.001 and 0.004, respectively), and active abduction (p = 0.001) compared with stiff aTSAs. The outcome scores were significantly more favourable in stiff rTSAs for the Shoulder Pain and Disability Index, Simple Shoulder Test, American Shoulder and Elbow Surgeons score, University of California, Los Angeles score, and the Constant score, compared with stiff aTSAs. When comparing the proportion of stiff aTSAs versus stiff rTSAs that exceeded the minimal clinically important difference and substantial clinical benefit, stiff rTSAs achieved both at greater rates for all measurements except active ER. The complication rate did not significantly differ between stiff aTSAs and stiff rTSAs, but there was a significantly higher rate of revision surgery in stiff aTSAs (p = 0.007). Conclusion. Postoperative overhead ROM, outcome scores, and rates of revision surgery favour the use of a rTSA rather than aTSA in patients with glenohumeral OA, an intact rotator cuff and limited FE, with similar rotational ROM in these two groups. Cite this article: Bone Joint J 2023;105-B(12):1303–1313


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1334 - 1342
1 Dec 2022
Wilcox B Campbell RJ Low A Yeoh T

Aims. Rates of reverse total shoulder arthroplasty (rTSA) continue to grow. Glenoid bone loss and deformity remains a technical challenge to the surgeon and may reduce improvements in patients’ outcomes. However, there is no consensus as to the optimal surgical technique to best reconstruct these patients’ anatomy. This review aims to compare the outcomes of glenoid bone grafting versus augmented glenoid prostheses in the management of glenoid bone loss in primary reverse total shoulder arthroplasty. Methods. This systematic review and meta-analysis evaluated study-level data in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. We performed searches of Medline (Ovid), Embase (Ovid), and PubMed from their dates of inception to January 2022. From included studies, we analyzed data for preoperative and postoperative range of motion (ROM), patient-reported functional outcomes, and complication rates. Results. A total of 13 studies (919 shoulders) were included in the analysis. The mean age of patients at initial evaluation was 72.2 years (42 to 87), with a mean follow-up time of 40.7 months (24 to 120). Nine studies with 292 rTSAs evaluated the use of bone graft and five studies with 627 rTSAs evaluated the use of augmented glenoid baseplates. One study was analyzed in both groups. Both techniques demonstrated improvement in patient-reported outcome measures and ROM assessment, with augmented prostheses outperforming bone grafting on improvements in the American Shoulder and Elbow Surgeons Score. There was a higher complication rate (8.9% vs 3.5%; p < 0.001) and revision rate among the bone grafting group compared with the patients who were treated with augmented prostheses (2.4% vs 0.6%; p = 0.022). Conclusion. This review provides strong evidence that both bone graft and augmented glenoid baseplate techniques to address glenoid bone loss give excellent ROM and functional outcomes in primary rTSA. The use of augmented base plates may confer fewer complications and revisions. Cite this article: Bone Joint J 2022;104-B(12):1334–1342


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 126 - 130
1 Jun 2021
Chalmers BP Goytizolo E Mishu MD Westrich GH

Aims. Manipulation under anaesthesia (MUA) remains an effective intervention to address restricted range of motion (ROM) after total knee arthroplasty (TKA) and occurs in 2% to 3% of primary TKAs at our institution. Since there are few data on the outcomes of MUA with different anaesthetic methods, we sought to compare the outcomes of patients undergoing MUA with intravenous (IV) sedation and neuraxial anaesthesia. Methods. We identified 548 MUAs after primary TKA (136 IV sedation, 412 neuraxial anaesthesia plus IV sedation) from March 2016 to July 2019. The mean age of this cohort was 62 years (35 to 88) with a mean body mass index of 31 kg/m. 2. (18 to 49). The mean time from primary TKA to MUA was 10.2 weeks (6.2 to 24.3). Pre-MUA ROM was similar between groups; overall mean pre-MUA extension was 4.2° (p = 0.452) and mean pre-MUA flexion was 77° (p = 0.372). We compared orthopaedic complications, visual analogue scale (VAS) pain scores, length of stay (LOS), and immediate and three-month follow-up knee ROM between these groups. Results. Following MUA, patients with IV sedation had higher mean VAS pain scores of 5.2 (SD 1.8) compared to 4.1 (SD = 1.5) in the neuraxial group (p < 0.001). The mean LOS was shorter in patients that received IV sedation (9.5 hours (4 to 31)) compared to neuraxial anaesthesia (11.9 hours (4 to 51)) (p = 0.009), but an unexpected overnight stay was similar in each group (8.6%). Immediate-post MUA ROM was 1° to 121° in the IV sedation group and 0.9° to 123° in the neuraxial group (p = 0.313). Three-month follow-up ROM was 2° to 108° in the IV sedation group and 1.9° to 110° in the neuraxial anaesthesia group (p = 0.325) with a mean loss of 13° (ranging from 5° gain to 60° loss), in both groups by three months. No patients in either group sustained a complication. Conclusion. IV sedation alone and neuraxial anaesthesia are both effective anaesthetic methods for MUA after primary TKA. Surgeons and anaesthetists should offer these anaesthetic techniques to match patient-specific needs as the orthopaedic outcomes are similar. Also, patients should be counselled that ROM following MUA may decrease over time. Cite this article: Bone Joint J 2021;103-B(6 Supple A):126–130


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 426 - 433
1 Apr 2020
Boettner F Sculco P Faschingbauer M Rueckl K Windhager R Kasparek MF

Aims. To compare patients undergoing total knee arthroplasty (TKA) with ≤ 80° range of movement (ROM) operated with a 2 mm increase in the flexion gap with matched non-stiff patients with at least 100° of preoperative ROM and balanced flexion and extension gaps. Methods. In a retrospective cohort study, 98 TKAs (91 patients) with a preoperative ROM of ≤ 80° were examined. Mean follow-up time was 53 months (24 to 112). All TKAs in stiff knees were performed with a 2 mm increased flexion gap. Data were compared to a matched control group of 98 TKAs (86 patients) with a mean follow-up of 43 months (24 to 89). Knees in the control group had a preoperative ROM of at least 100° and balanced flexion and extension gaps. In all stiff and non-stiff knees posterior stabilized (PS) TKAs with patellar resurfacing in combination with adequate soft tissue balancing were used. Results. Overall mean ROM in stiff knees increased preoperatively from 67° (0° to 80°) to 114° postoperatively (65° to 135°) (p < 0.001). Mean knee flexion improved from 82° (0° to 110°) to 115° (65° to 135°) and mean flexion contracture decreased from 14° (0° to 50°) to 1° (0° to 10°) (p < 0.001). The mean Knee Society Score (KSS) improved from 34 (0 to 71) to 88 (38 to 100) (p < 0.001) and the KSS Functional Score from 43 (0 to 70) to 86 (0 to 100). Seven knees (7%) required manipulations under anaesthesia (MUA) and none of the knees had flexion instability. The mean overall ROM in the control group improved from 117° (100° to 140°) to 123° (100° to 130°) (p < 0.001). Mean knee flexion improved from 119° (100° to 140°) to 123° (100° to 130°) (p < 0.001) and mean flexion contracture decreased from 2° (0° to 15°) to 0° (0° to 5°) (p < 0.001). None of the knees in the control group had flexion instability or required MUA. The mean KSS Knee Score improved from 48 (0 to 80) to 94 (79 to 100) (p < 0.001) and the KSS Functional Score from 52 (5 to 100) to 95 (60 to 100) (p < 0.001). Mean improvement in ROM (p < 0.001) and KSS Knee Score (p = 0.017) were greater in knees with preoperative stiffness compared with the control group, but the KSS Functional Score improvement was comparable (p = 0.885). Conclusion. TKA with a 2 mm increased flexion gap provided a significant improvement of ROM in knees with preoperative stiffness. While the improvement in ROM was greater, the absolute postoperative ROM was less than in matched non-stiff knees. PS TKA with patellar resurfacing and a 2 mm increased flexion gap, in combination with adequate soft tissue balancing, provides excellent ROM and knee function when stiffness of the knee had been present preoperatively. Cite this article: Bone Joint J 2020;102-B(4):426–433


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 66 - 72
1 Jun 2020
Knapp P Weishuhn L Pizzimenti N Markel DC

Aims. Postoperative range of movement (ROM) is an important measure of successful and satisfying total knee arthroplasty (TKA). Reduced postoperative ROM may be evident in up to 20% of all TKAs and negatively affects satisfaction. To improve ROM, manipulation under anaesthesia (MUA) may be performed. Historically, a limited ROM preoperatively was used as the key harbinger of the postoperative ROM. However, comorbidities may also be useful in predicting postoperative stiffness. The goal was to assess preoperative comorbidities in patients undergoing TKA relative to incidence of postoperative MUA. The hope is to forecast those who may be at increased risk and determine if MUA is an effective form of treatment. Methods. Prospectively collected data of TKAs performed at our institution’s two hospitals from August 2014 to August 2018 were evaluated for incidence of MUA. Comorbid conditions, risk factors, implant component design and fixation method (cemented vs cementless), and discharge disposition were analyzed. Overall, 3,556 TKAs met the inclusion criteria. Of those, 164 underwent MUA. Results. Patients with increased age and body mass index (BMI) had decreased likelihood of MUA. For every one-year increase in age, the likelihood of MUA decreased by 4%. Similarly, for every one-unit increase in BMI the likelihood of MUA decreased by 6%. There were no differences in incidence of MUA between component type/design or fixation method. Current or former smokers were more likely to have no MUA. Surprisingly, patients discharged to home health service or skilled nursing facility were approximately 40% and 70% less likely than those discharged home with outpatient therapy to be in the MUA group. MUA was effective, with a mean increased ROM of 32.81° (SD 19.85°; -15° to 90°). Conclusion. Younger, thinner patients had highest incidence of MUA. Effect of discharge disposition on rate of MUA was an important finding and may influence surgeons’ decisions. Interestingly, use of cement and component design (constraint) did not impact incidence of MUA. Level of Evidence II: Prospective cohort study. Cite this article: Bone Joint J 2020;102-B(6 Supple A):66–72


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 246 - 253
1 Feb 2020
Alluri RK Lightdale-Miric N Meisel E Kim G Kaplan J Bougioukli S Stevanovic M

Aims. To describe and analyze the mid-term functional outcomes of a large series of patients who underwent the Hoffer procedure for brachial plexus birth palsy (BPBP). Methods. All patients who underwent the Hoffer procedure with minimum two-year follow-up were retrospectively reviewed. Active shoulder range of movement (ROM), aggregate modified Mallet classification scores, Hospital for Sick Children Active Movement Scale (AMS) scores, and/or Toronto Test Scores were used to assess functional outcomes. Subgroup analysis based on age and level of injury was performed. Risk factors for subsequent humeral derotational osteotomy and other complications were also assessed. A total of 107 patients, average age 3.9 years (1.6 to 13) and 59% female, were included in the study with mean 68 months (24 to 194) follow-up. Results. All patients demonstrated statistically significant improvement in all functional outcomes and active shoulder abduction and external rotation ROM (p < 0.001). Patients < 2.5 years of age had higher postoperative AMS, abduction ROM and strength scores, and aggregate postoperative Toronto scores (p ≤ 0.035) compared to patients ≥ 2.5 years old. There were 17 patients (16%) who required a subsequent humeral derotational osteotomy; lower preoperative AMS external rotation scores and external rotation ROM were predictive risk factors (p ≤ 0.016). Conclusion. Patients with BPBP who underwent the Hoffer procedure demonstrated significant improvement in postoperative ROM, strength, and functional outcome scores at mid-term follow-up. Patients younger than 2.5 years at the time of surgery generally had better functional outcomes. Limited preoperative external rotation strength and ROM were significantly associated with requirement for subsequent humeral derotational osteotomy. In our chort significant improvements in shoulder function were obtained after the Hoffer procedure for BPBP. Cite this article: Bone Joint J 2020;102-B(2):246–253


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 993 - 999
1 Sep 2023
van Delft EAK van Bruggen SGJ van Stralen KJ Bloemers FW Sosef NL Schep NWL Vermeulen J

Aims. There is no level I evidence dealing with the optimal period of immobilization for patients with a displaced distal radial fracture following closed reduction. A shorter period might lead to a better functional outcome due to less stiffness and pain. The aim of this study was to investigate whether this period could be safely reduced from six to four weeks. Methods. This multicentre randomized controlled trial (RCT) included adult patients with a displaced distal radial fracture, who were randomized to be treated with immobilization in a cast for four or six weeks following closed reduction. The primary outcome measure was the Patient-Rated Wrist Evaluation (PRWE) score after follow-up at one year. Secondary outcomes were the abbreviated version of the Disability of Arm, Shoulder and Hand (QuickDASH) score after one year, the functional outcome at six weeks, 12 weeks, and six months, range of motion (ROM), the level of pain after removal of the cast, and complications. Results. A total of 100 patients (15 male, 85 female) were randomized, with 49 being treated with four weeks of immobilization in a cast. A total of 93 completed follow-up. The mean PRWE score after one year was 6.9 (SD 8.3) in the four-week group compared with 11.6 (SD 14.3) in the six-week group. However, this difference of -4.7 (95% confidence interval -9.29 to 0.14) was not clinically relevant as the minimal clinically important difference of 11.5 was not reached. There was no significant difference in the ROM, radiological outcome, level of pain, or complications. Conclusion. In adult patients with a displaced and adequately reduced distal radial fracture, immobilization in a cast for four weeks is safe, and the results are similar to those after a period of immobilization of six weeks. Cite this article: Bone Joint J 2023;105-B(9):993–999


Aims. Total knee arthroplasty (TKA) may provoke ankle symptoms. The aim of this study was to validate the impact of the preoperative mechanical tibiofemoral angle (mTFA), the talar tilt (TT) on ankle symptoms after TKA, and assess changes in the range of motion (ROM) of the subtalar joint, foot posture, and ankle laxity. Methods. Patients who underwent TKA from September 2020 to September 2021 were prospectively included. Inclusion criteria were primary end-stage osteoarthritis (Kellgren-Lawrence stage IV) of the knee. Exclusion criteria were missed follow-up visit, post-traumatic pathologies of the foot, and neurological disorders. Radiological angles measured included the mTFA, hindfoot alignment view angle, and TT. The Foot Function Index (FFI) score was assessed. Gait analyses were conducted to measure mediolateral changes of the gait line and ankle laxity was tested using an ankle arthrometer. All parameters were acquired one week pre- and three months postoperatively. Results. A total of 69 patients (varus n = 45; valgus n = 24) underwent TKA and completed the postoperative follow-up visit. Of these, 16 patients (23.2%) reported the onset or progression of ankle symptoms. Varus patients with increased ankle symptoms after TKA had a significantly higher pre- and postoperative TT. Valgus patients with ankle symptoms after TKA showed a pathologically lateralized gait line which could not be corrected through TKA. Patients who reported increased ankle pain neither had a decreased ROM of the subtalar joint nor increased ankle laxity following TKA. The preoperative mTFA did not correlate with the postoperative FFI (r = 0.037; p = 0.759). Conclusion. Approximately one-quarter of the patients developed ankle pain after TKA. If patients complain about ankle symptoms after TKA, standing radiographs of the ankle and a gait analysis could help in detecting a malaligned TT or a pathological gait. Cite this article: Bone Joint J 2023;105-B(11):1159–1167


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 426 - 434
1 Apr 2019
Logishetty K van Arkel RJ Ng KCG Muirhead-Allwood SK Cobb JP Jeffers JRT

Aims. The hip’s capsular ligaments passively restrain extreme range of movement (ROM) by wrapping around the native femoral head/neck. We determined the effect of hip resurfacing arthroplasty (HRA), dual-mobility total hip arthroplasty (DM-THA), conventional THA, and surgical approach on ligament function. Materials and Methods. Eight paired cadaveric hip joints were skeletonized but retained the hip capsule. Capsular ROM restraint during controlled internal rotation (IR) and external rotation (ER) was measured before and after HRA, DM-THA, and conventional THA, with a posterior (right hips) and anterior capsulotomy (left hips). Results. Hip resurfacing provided a near-native ROM with between 5° to 17° increase in IR/ER ROM compared with the native hip for the different positions tested, which was a 9% to 33% increase. DM-THA generated a 9° to 61° (18% to 121%) increase in ROM. Conventional THA generated a 52° to 100° (94% to 199%) increase in ROM. Thus, for conventional THA, the capsule function that exerts a limit on ROM is lost. It is restored to some extent by DM-THA, and almost fully restored by hip resurfacing. In positions of low flexion/extension, the posterior capsulotomy provided more normal function than the anterior, possibly because the capsule was shortened during posterior repair. However, in deep flexion positions, the anterior capsulotomy functioned better. Conclusion. Native head-size and capsular repair preserves capsular function after arthroplasty. The anterior and posterior approach differentially affect postoperative biomechanical function of the capsular ligaments. Cite this article: Bone Joint J 2019;101-B:426–434


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1271 - 1278
1 Dec 2023
Rehman Y Korsvold AM Lerdal A Aamodt A

Aims. This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS). Methods. Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed. Results. Patients reported similar levels of pain, function, satisfaction, and general health regardless of the prosthetic design they received. Mean maximal flexion (129° (95% confidence interval (CI) 127° to 131°) was greater in the PS group than in the CR (120° (95% CI 121° to 124°)) and AS groups (122° (95% CI 120° to 124°)). Conclusion. Despite differences in design and constraint, CR, AS, and PS designs from a single TKA system resulted in no differences in patient-reported outcomes at two-year follow-up. PS patients had statistically better ROM, but the clinical significance of this finding is unclear. Cite this article: Bone Joint J 2023;105-B(12):1271–1278


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims. The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes. Methods. This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group). Results. Perforation of the vault of the glenoid (p = 0.018) and size mismatch in height (p < 0.001) and width (p = 0.013) were significantly more frequent in the ST group than in the SM group. There was no significant difference in the clinical scores and ROM in the two groups, two years postoperatively (all p > 0.05). In subgroup analysis, the VP group had significantly less inferior overhang (p = 0.009), more scapular notching (p = 0.018), and more size mismatch in height (p < 0.001) and width (p = 0.025) than the VNP group. Conclusion. In Asian patients with a small glenoid, using a 29.5 mm small baseplate at the time of RSA was more effective in reducing size mismatch between the glenoid and the baseplate, decreasing the incidence of perforation of the glenoid vault, and achieving optimal positioning of the baseplate compared with the use of a 33.8 mm standard baseplate. However, longer follow-up is required to assess the impact of these findings on the clinical outcomes. Cite this article: Bone Joint J 2023;105-B(11):1189–1195


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1421 - 1427
1 Aug 2021
Li J Lu Y Chen G Li M Xiao X Ji C Wang Z Guo Z

Aims. We have previously reported cryoablation-assisted joint-sparing surgery for osteosarcoma with epiphyseal involvement. However, it is not clear whether this is a comparable alternative to conventional joint arthroplasty in terms of oncological and functional outcomes. Methods. A total of 22 patients who had localized osteosarcoma with epiphyseal involvement around the knee and underwent limb salvage surgery were allocated to joint preservation (JP) group and joint arthroplasty (JA) group. Subjects were followed with radiographs, Musculoskeletal Tumor Society (MSTS) score, and clinical evaluations at one, three, and five years postoperatively. Results. Patients in both groups (ten in JP and 12 in JA) did not differ in local recurrence (p ≥ 0.999) and occurrence of metastases (p ≥ 0.999). Overall survival was similar in both groups (p = 0.858). Patients in the JP group had less range of motion (ROM) of the knee (p < 0.001) and lower MSTS scores (p = 0.010) compared with those of the JA group only at one year postoperatively. There was no difference between groups either at three years for ROM (p = 0.185) and MSTS score (p = 0.678) or at five years for ROM (p = 0.687) and MSTS score (p = 0.536), postoperatively. Patients in the JA group tended to have more complications (p = 0.074). Survival of primary reconstruction in the JP group was better than that of the JA group (p = 0.030). Conclusion. Cryoablation-aided joint-sparing surgery offers native joint preservation with comparable functional recovery and more durable reconstruction without jeopardizing oncological outcomes compared with conventional limb salvage surgery. Cite this article: Bone Joint J 2021;103-B(8):1421–1427


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 88 - 96
1 Jan 2023
Vogt B Rupp C Gosheger G Eveslage M Laufer A Toporowski G Roedl R Frommer A

Aims. Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences. Methods. A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages. Results. Osteolysis next to the telescopic junction was observed in 31/48 segments (65%) lengthened with the STRYDE nail before implant removal compared to 1/91 segment (1%) in the PRECICE cohort. In the STRYDE cohort, osteolysis initially increased, but decreased or resolved in almost all lengthened segments (86%) after implant removal. Implant failure was observed in 9/48 STRYDE (19%) and in 8/92 PRECICE nails (9%). Breakage of the distal locking bolts was found in 5/48 STRYDE nails (10%) compared to none in the PRECICE cohort. Treatment-associated pain was generally recorded as mild and found in 30/48 patients (63%) and 39/92 (42%) in the STRYDE and PRECICE cohorts, respectively. Temporary range of motion (ROM) limitations under distraction were registered in 17/48 (35%) segments treated with the STRYDE and 35/92 segments (38%) treated with the PRECICE nail. Conclusion. Osteolysis and periosteal reaction, implant breakage, and pain during lengthening and consolidation is more likely in patients treated with the STRYDE nail compared to the PRECICE nail. Temporary ROM limitations during lengthening occurred independent of the applied device. Implant-related osseous alterations seem to remodel after implant removal. Cite this article: Bone Joint J 2023;105-B(1):88–96


Aims. Intravenous dexamethasone has been shown to reduce immediate postoperative pain after total hip arthroplasty (THA), though the effects are short-lived. We aimed to assess whether two equivalent perioperative split doses were more effective than a single preoperative dose. Methods. A total of 165 patients were randomly assigned into three groups: two perioperative saline injections (Group A, placebo), a single preoperative dose of 20 mg dexamethasone and a postoperative saline injection (Group B), and two perioperative doses of 10 mg dexamethasone (Group C). Patients, surgeons, and staff collecting outcome data were blinded to allocation. The primary outcome was postoperative pain level reported on a ten-point Numerical Rating Scale (NRS) at rest and during activity. The use of analgesic and antiemetic rescue, incidence of postoperative nausea and vomiting (PONV), CRP and interleukin-6 (IL-6) levels, range of motion (ROM), length of stay (LOS), patient satisfaction, and the incidence of surgical site infection (SSI) and gastrointestinal bleeding (GIB) in the three months postoperatively, were also compared. Results. The pain scores at rest were significantly lower in Groups B and C than in Group A on postoperative days 1 and 2. The dynamic pain scores and CRP and IL-6 levels were significantly lower for Groups B and C compared to Group A on postoperative days 1, 2, and 3. Patients in Groups B and C had a lower incidence of PONV, reduced use of analgesic and antiemetic rescue, improved ROM, shorter LOS, and reported higher satisfaction than in Group A. Patients in Group C had significantly lower dynamic pain scores and IL-6 and CRP levels on postoperative days 2 and 3, and higher ROM and satisfaction on postoperative day 3 than in Group B. No SSI or GIB occurred in any group. Conclusion. Perioperative dexamethasone provides short-term advantages in reducing pain, PONV, and inflammation, and increasing range of motion in the early postoperative period after THA. A split-dose regimen was superior to a single high dose in reducing pain and inflammation, and increasing ROM, with better patient satisfaction. Level of evidence: I. Cite this article: Bone Joint J 2020;102-B(11):1497–1504


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 981 - 996
1 Aug 2020
Yang Y Zhao H Chai Y Zhao D Duan L Wang H Zhu J Yang S Li C Chen S Chae S Song J Wang X Yu X

Aims. Whether to perform hybrid surgery (HS) in contrast to anterior cervical discectomy and fusion (ACDF) when treating patients with multilevel cervical disc degeneration remains a controversial subject. To resolve this we have undertaken a meta-analysis comparing the outcomes from HS with ACDF in this condition. Methods. Seven databases were searched for studies of HS and ACDF from inception of the study to 1 September 2019. Both random-effects and fixed-effects models were used to evaluate the overall effect of the C2-C7 range of motion (ROM), ROM of superior/inferior adjacent levels, adjacent segment degeneration (ASD), heterotopic ossification (HO), complications, neck disability index (NDI) score, visual analogue scale (VAS) score, Japanese Orthopaedic Association (JOA) score, Odom’s criteria, blood loss, and operating and hospitalization time. To obtain more credible results contour-enhanced funnel plots, Egger’s and Begg’s tests, meta-regression, and sensitivity analyses were performed. Results. In total, 17 studies involving 861 patients were included in the analysis. HS was found to be superior to ACDF in maintaining C2-C7 ROM and ROM of superior/inferior adjacent levels, but HS did not reduce the incidence of associated level ASD. Also, HS did not cause a higher rate of HO than ACDF. The frequency of complications was similar between the two techniques. HS failed to achieve more favourable outcomes than ACDF using the NDI, VAS, JOA, and Odom’s scores. HS did not show any more advantages in operating or hospitalization time but did show reduction in blood loss. Conclusion. Although HS maintained cervical kinetics, it failed to reduce the incidence of ASD. This finding differs from previous reports. Moreover, patients did not show more benefits from HS with respect to symptom improvement, prevention of complications, and clinical outcomes. Cite this article: Bone Joint J 2020;102-B(8):981–996


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 91 - 95
1 Jun 2020
Johnson, Jr. WB Engh, Jr. CA Parks NL Hamilton WG Ho PH Fricka KB

Aims. It has been hypothesized that a unicompartmental knee arthroplasty (UKA) is more likely to be revised than a total knee arthroplasty (TKA) because conversion surgery to a primary TKA is a less complicated procedure. The purpose of this study was to determine if there is a lower threshold for revising a UKA compared with TKA based on Oxford Knee Scores (OKSs) and range of movement (ROM) at the time of revision. Methods. We retrospectively reviewed 619 aseptic revision cases performed between December 1998 and October 2018. This included 138 UKAs that underwent conversion to TKA and 481 initial TKA revisions. Age, body mass index (BMI), time in situ, OKS, and ROM were available for all patients. Results. There were no differences between the two groups based on demographics or time to revision. The top reasons for aseptic TKA revision were loosening in 212 (44%), instability in 88 (18%), and wear in 69 (14%). UKA revision diagnoses were primarily for loosening in 50 (36%), progression of osteoarthritis (OA) in 50 (36%), and wear in 17 (12%). Out of a maximum 48 points, the mean OKS of the UKAs before revision was 23 (SD 9.3), which was significantly higher than the TKAs at 19.2 (SD 9.8; p < 0.001). UKA patients scored statistically better on nine of the 12 individual OKS questions. The UKA cases also had a larger pre-revision mean ROM (114°, SD 14.3°) than TKAs (98°, SD 25°) ; p < 0.001). Conclusion. At revision, the mean UKA OKSs and ROM were significantly better than those of TKA cases. This study suggests that at our institution there is a difference in preoperative OKS between UKA and TKA at the time of revision, demonstrating a revision bias. Cite this article: Bone Joint J 2020;102-B(6 Supple A):91–95


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1174 - 1179
1 Oct 2022
Jamshidi K Bagherifard A Mirzaei A

Aims. Osteoarticular reconstruction of the distal femur in childhood has the advantage of preserving the tibial physis. However, due to the small size of the distal femur, matching the host bone with an osteoarticular allograft is challenging. In this study, we compared the outcomes and complications of a resurfaced allograft-prosthesis composite (rAPC) with those of an osteoarticular allograft to reconstruct the distal femur in children. Methods. A retrospective analysis of 33 skeletally immature children with a malignant tumour of the distal femur, who underwent resection and reconstruction with a rAPC (n = 15) or osteoarticular allograft (n = 18), was conducted. The median age of the patients was ten years (interquartile range (IQR) 9 to 11) in the osteoarticular allograft group and nine years (IQR 8 to 10) in the rAPC group (p = 0.781). The median follow-up of the patients was seven years (IQR 4 to 8) in the osteoarticular allograft group and six years (IQR 3 to 7) in the rAPC group (p = 0.483). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS) score. Results. At final follow-up, the knee was unstable in 9/18 patients (50%) in the osteoarticular allograft group and 2/15 patients (13%) in the rAPC group (p = 0.026). The median range of motion (ROM) of the knee was 117° (IQR 115° to 120°) in the osteoarticular allograft group and 100° (IQR 95° to 105°) in the rAPC group (p < 0.001). The median MSTS score was 25 (IQR 23 to 26) in the osteoarticular allograft group and 28 (IQR 26 to 29) in the rAPC group (p = 0.007). Osteoarthritic change was detected in 11/18 patients (61%) in the osteoarticular allograft group and in 4/15 (26%) patients in the rAPC group (p = 0.048). Conclusion. In our series, a resurfaced allograft-prosthesis composite provided better knee stability and function, with a lower rate of osteoarthritis; an osteoarticular allograft was associated with better knee ROM. Cite this article: Bone Joint J 2022;104-B(10):1174–1179


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims. Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up. Methods. This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36). Results. There were no differences between the two treatment groups with regard to mean change in haemoglobin concentration (p = 0.477), length of stay (LOS, p = 0.172), mean polyethylene thickness (p = 0.065), or postoperative complication rates (p = 0.295). At the most recent follow-up, the primary robotic arm-assisted TKA group had a statistically significantly improved OKS compared with the revision UKA to TKA group (44.6 (SD 2.7) vs 42.3 (SD 2.5); p = 0.004) but there was no difference in the overall ROM (p = 0.056) or FJS between the two treatment groups (86.1 (SD 9.6) vs 84.1 (4.9); p = 0.439). Conclusion. Robotic arm-assisted revision of UKA to TKA was associated with comparable intraoperative blood loss, early postoperative rehabilitation, functional outcomes, and complications to primary robotic TKA at short-term follow-up. Robotic arm-assisted surgery offers a safe and reproducible technique for revising failed UKA to TKA. Cite this article: Bone Joint J 2024;106-B(7):680–687


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims. The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design. Methods. This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m. 2. (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions. Results. A total of 24 TKAs (3.4%) in 24 patients failed and required revision surgery, of which five were due to patellar complications (0.71%): one for aseptic patellar loosening (0.14%) and four for polyethylene dissociation (0.57%). A total of 19 revisions (2.7%) were undertaken in 19 patients for indications which did not relate to the patella: four for aseptic tibial loosening (0.57%), one for aseptic femoral loosening (0.14%), nine for periprosthetic infection (1.3%), one for popliteus impingement (0.14%), and four for instability (0.57%). Knee Society knee and function scores, and ROM, improved significantly when comparing pre- and postoperative values. Survival of the metal-backed patellar component for all-cause failure was 97.5% (95% confidence interval 94.9% to 100%) at 12 years. Conclusion. The second-generation cementless TKA design of metal-backed patellar components showed a 97.5% survival at 12 years, with polyethylene dissociation from the metal-backing being the most common cause of patellar failure. In view of the increased use of TKA, especially in younger, more active, or obese patients, these findings are encouraging at mean follow-up of seven years. Cite this article: Bone Joint J 2023;105-B(12):1279–1285


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 486 - 494
4 Apr 2022
Liu W Sun Z Xiong H Liu J Lu J Cai B Wang W Fan C

Aims. The aim of this study was to develop and internally validate a prognostic nomogram to predict the probability of gaining a functional range of motion (ROM ≥ 120°) after open arthrolysis of the elbow in patients with post-traumatic stiffness of the elbow. Methods. We developed the Shanghai Prediction Model for Elbow Stiffness Surgical Outcome (SPESSO) based on a dataset of 551 patients who underwent open arthrolysis of the elbow in four institutions. Demographic and clinical characteristics were collected from medical records. The least absolute shrinkage and selection operator regression model was used to optimize the selection of relevant features. Multivariable logistic regression analysis was used to build the SPESSO. Its prediction performance was evaluated using the concordance index (C-index) and a calibration graph. Internal validation was conducted using bootstrapping validation. Results. BMI, the duration of stiffness, the preoperative ROM, the preoperative intensity of pain, and grade of post-traumatic osteoarthritis of the elbow were identified as predictors of outcome and incorporated to construct the nomogram. SPESSO displayed good discrimination with a C-index of 0.73 (95% confidence interval 0.64 to 0.81). A high C-index value of 0.70 could still be reached in the interval validation. The calibration graph showed good agreement between the nomogram prediction and the outcome. Conclusion. The newly developed SPESSO is a valid and convenient model which can be used to predict the outcome of open arthrolysis of the elbow. It could assist clinicians in counselling patients regarding the choice and expectations of treatment. Cite this article: Bone Joint J 2022;104-B(4):486–494


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 680 - 686
1 Jun 2022
Robinson JR Bruce D Davies H Porteous AJ Murray JRD Howells NR

Aims. The best surgical strategy for the management of displaced bucket-handle (BH) meniscal tears in an anterior cruciate ligament (ACL)-deficient knee is unclear. Combining meniscal repair with ACL reconstruction (ACLR) is thought to improve meniscal healing rates; however, patients with displaced BH meniscal tears may lack extension. This leads some to advocate staged surgery to avoid postoperative stiffness and loss of range of motion (ROM) following ACLR. Methods. We reviewed the data for a consecutive series of 88 patients (mean age 27.1 years (15 to 49); 65 male (74%) and 23 female (26%)) who underwent single-stage repair of a displaced BH meniscal tear (67 medial (76%) and 21 lateral (24%)) with concomitant hamstring autograft ACLR. The patient-reported outcome measures (PROMs) EuroQol visual analogue scale (EQ-VAS), EuroQol five-dimension health questionnaire (EQ-5D), Knee injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee score (IKDC), and Tegner score were recorded at final follow-up. A Kaplan-Meier survival analysis was performed to estimate meniscal repair survivorship. Analyses were performed with different cut-offs for meniscal and ACL injury-to-surgery time (within three weeks, three to ten weeks, and more than ten weeks). Results. Meniscal repair survivorship at a median final follow-up of 55 months (interquartile range (IQR) 24 to 91) was 82% (95% confidence interval 70 to 89). A total of 13 meniscus repairs failed (12 requiring meniscectomy and one requiring a further meniscal repair). At final follow-up, median PROMs were: EQ-VAS 85 (IQR 75 to 90), EQ-5D Index 0.84 (IQR 0.74 to 1.00), KOOS Pain 89 (IQR 80 to 94), KOOS Symptoms 82 (IQR 71 to 93), KOOS Activities of Daily Living 97 (IQR 91 to 100), KOOS Sport and Recreation 80 (IQR 65 to 90), KOOS Quality of Life 69 (IQR 53 to 86), IKDC 82.8 (IQR 67.8 to 90.8), and Tegner 6 (IQR 4 to 7). Two patients underwent revision ACLR following further injuries. One patient had an arthroscopic washout for infection at 11 days post-BH meniscal repair/ACLR. Four patients (4.5%) required a further procedure for stiffness, reduced ROM, and pain, and all were operated on within three weeks of meniscal injury. There was no difference in the interval between meniscal injury and surgery between repairs that failed and those that survived. Conclusion. These data suggest that concomitant ACLR with repair of displaced BH meniscal tears, even if they have been displaced for some time, appears to afford satisfactory PROMs and good survivorship. Repairs within three weeks of meniscal injury may be associated with higher rates of postoperative reintervention for stiffness. Cite this article: Bone Joint J 2022;104-B(6):680–686


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1608 - 1617
1 Dec 2020
Castioni D Mercurio M Fanelli D Cosentino O Gasparini G Galasso O

Aims. The aim of this systematic review and meta-analysis is to evaluate differences in functional outcomes and complications between single- (SI) and double-incision (DI) techniques for the treatment of distal biceps tendon rupture. Methods. A comprehensive search on PubMed, MEDLINE, Scopus, and Cochrane Central databases was conducted to identify studies reporting comparative results of the SI versus the DI approach. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement was used for search strategy. Of 606 titles, 13 studies met the inclusion criteria; methodological quality was assessed with the Newcastle-Ottawa scale. Random- and fixed-effects models were used to find differences in outcomes between the two surgical approaches. The range of motion (ROM) and the Disabilities of the Arm, Shoulder and Hand (DASH) scores, as well as neurological and non-neurological complications, were assessed. Results. A total of 2,622 patients were identified. No significant differences in DASH score were detected between the techniques. The SI approach showed significantly greater ROM in flexion (standardized mean difference (SMD) -0.508; 95% confidence interval (CI) -0.904 to -0.112) and pronation (SMD -0.325, 95% CI -0.637 to -0.012). The DI technique was associated with significantly less risk of lateral antebrachial cutaneous nerve damage (odds ratio (OR) 4.239, 95% CI 2.171 to 8.278), but no differences were found for other nerves evaluated. The SI group showed significantly fewer events of heterotopic ossification (OR 0.430, 95% CI 0.226 to 0.816) and a lower reoperation rate (OR 0.503, 95% CI 0.317 to 0.798). Conclusion. No significant differences in functional scores can be expected between the SI and DI approaches after distal biceps tendon repair. The SI approach showed greater flexion and pronation ROM and a lower risk of heterotopic ossification and reoperation. The DI approach was favourable in terms of lower risk of neurological complications. Cite this article: Bone Joint J 2020;102-B(12):1608–1617


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 91 - 96
1 Jan 2022
Modi A Haque A Deore V Singh HP Pandey R

Aims. Long-term outcomes following the use of human dermal allografts in the treatment of symptomatic irreparable rotator cuff tears are not known. The aim of this study was to evaluate these outcomes, and to investigate whether this would be a good form of treatment in young patients in whom a reverse shoulder arthroplasty should ideally be avoided. Methods. This prospective study included 47 shoulders in 45 patients who underwent an open reconstruction of the rotator cuff using an interposition GraftJacket allograft to bridge irreparable cuff tears, between January 2007 and November 2011. The Oxford Shoulder Score (OSS), pain score, and range of motion (ROM) were recorded preoperatively and at one year and a mean of 9.1 years (7.0 to 12.5) postoperatively. Results. There was significant improvement in the mean OSS from 24.7 (SD 5.4) preoperatively to 42.0 (SD 6.3) at one year, and this improvement was maintained at 9.1 years (p < 0.001), with a score of 42.8 (SD 6.8). Similar significant improvements in the pain score were seen and maintained at the final follow-up from 6.1 (SD 1.6) to 2.1 (SD 2.3) (p < 0.001). There were also significant improvements in the ROM of the shoulder, and patient satisfaction was high. Conclusion. The use of an interposition human dermal allograft in patients with an irreparable rotator cuff tear leads to good outcomes that are maintained at a mean of nine years postoperatively. Cite this article: Bone Joint J 2022;104-B(1):91–96


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 84 - 90
1 Jul 2019
Jennings JM Loyd BJ Miner TM Yang CC Stevens-Lapsley J Dennis DA

Aims. The aim of this study was to determine whether closed suction drain (CSD) use influences recovery of quadriceps strength and to examine the effects of drain use on secondary outcomes: quadriceps activation, intra-articular effusion, bioelectrical measure of swelling, range of movement (ROM), pain, and wound healing complications. Patients and Methods. A total of 29 patients undergoing simultaneous bilateral total knee arthroplasty (TKA) were enrolled in a prospective, randomized blinded study. Patients were randomized to receive a CSD in one limb while the contralateral limb had the use of a subcutaneous drain (SCDRN) without the use of suction (‘sham drain’). Isometric quadriceps strength was collected as the primary outcome. Secondary outcomes consisted of quadriceps activation, intra-articular effusion measured via ultrasound, lower limb swelling measured with bioelectrical impendence and limb girth, knee ROM, and pain. Outcomes were assessed preoperatively and postoperatively at day two, two and six weeks, and three months. Differences between limbs were determined using paired Student’s t-tests or Wilcoxon’s signed-rank tests. Results. No significant differences were identified between limbs prior to surgery for the primary or secondary outcomes. No significant differences in quadriceps strength were seen between CSD and SCDRN limbs at postoperative day two (p = 0.09), two weeks (primary endpoint) (p = 0.7), six weeks (p = 0.3), or three months (p = 0.5). The secondary outcome of knee extension ROM was significantly greater in the CSD limb compared with the SCDRN (p = 0.01) at two weeks following surgery, but this difference was absent at all other intervals. Secondary outcomes of quadriceps activation, intra-articular effusion, lower limb swelling, and pain were not found to differ significantly at any timepoint following surgery. Conclusion. The use of CSD during TKA did not influence quadriceps strength, quadriceps activation, intra-articular effusion, lower limb swelling, ROM, or pain. These results have limited drain use by the authors in primary uncomplicated TKA. Cite this article: Bone Joint J 2019;101-B (7 Supple C):84–90


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 946 - 952
1 Aug 2022
Wu F Zhang Y Liu B

Aims. This study aims to report the outcomes in the treatment of unstable proximal third scaphoid nonunions with arthroscopic curettage, non-vascularized bone grafting, and percutaneous fixation. Methods. This was a retrospective analysis of 20 patients. All cases were delayed presentations (n = 15) or failed nonoperatively managed scaphoid fractures (n = 5). Surgery was performed at a mean duration of 27 months (7 to 120) following injury with arthroscopic debridement and arthroscopic iliac crest autograft. Fracture fixation was performed percutaneously with Kirschner (K)-wires in 12 wrists, a headless screw in six, and a combination of a headless screw and single K-wire in two. Clinical outcomes were assessed using grip strength, patient-reported outcome measures, and wrist range of motion (ROM) measurements. Results. Intraoperatively, established avascular necrosis of the proximal fragment was identified in ten scaphoids. All fractures united within 16 weeks, confirmed by CT. At a mean follow-up of 31 months (12 to 64), there were significant improvements in the Patient-Rated Wrist Evaluation, Mayo Wrist Score, abbreviated Disabilities of the Arm, Shoulder and Hand score, wrist ROM, grip strength, and the patients’ subjective pain score. No peri- or postoperative complications were encountered. Conclusion. Our data indicate that arthroscopic bone grafting and fixation with cancellous autograft is a viable method in the treatment of proximal third scaphoid nonunions, regardless of the vascularity of the proximal fragment. Cite this article: Bone Joint J 2022;104-B(8):946–952


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1292 - 1300
1 Jul 2021
Märtens N Heinze M Awiszus F Bertrand J Lohmann CH Berth A

Aims. The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed anatomical shoulder prostheses for treatment of osteoarthritis and to analyze radiological bone changes around the implants during follow-up. Methods. A total of 161 patients treated with either a stemmed or a stemless shoulder arthroplasty for primary osteoarthritis of the shoulder were evaluated with a mean follow-up of 118 months (102 to 158). The Constant score (CS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, and active range of motion (ROM) were recorded. Radiological analysis for bone adaptations was performed by plain radiographs. A Kaplan-Meier survivorship analysis was calculated and complications were noted. Results. The ROM (p < 0.001), CS (p < 0.001), and DASH score (p < 0.001) showed significant improvements after shoulder arthroplasty for both implants. There were no differences between the groups treated with stemmed or stemless shoulder prosthesis with respect to the mean CS (79.2 (35 to 118) vs 74.4 (31 to 99); p = 0.519) and DASH scores (11.4 (8 to 29) vs 13.2 (7 to 23); p = 0.210). The ten-year unadjusted cumulative survival rate was 95.3% for the stemmed anatomical shoulder prosthesis and 91.5% for the stemless shoulder prosthesis and did not differ between the treatment groups (p = 0.251). The radiological evaluation of the humeral components in both groups did not show loosening of the humeral implant. The main reason for revision for each type of arthroplasties were complications related to the glenoid. Conclusion. The use of anatomical stemless shoulder prosthesis yielded good and reliable results and did not differ from anatomical stemmed shoulder prosthesis over a mean period of ten years. The differences in periprosthetic humeral bone adaptations between both implants have no clinical impact during the follow-up. Cite this article: Bone Joint J 2021;103-B(7):1292–1300


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 902 - 907
1 May 2021
Marson BA Ng JWG Craxford S Chell J Lawniczak D Price KR Ollivere BJ Hunter JB

Aims. The management of completely displaced fractures of the distal radius in children remains controversial. This study evaluates the outcomes of surgical and non-surgical management of ‘off-ended’ fractures in children with at least two years of potential growth remaining. Methods. A total of 34 boys and 22 girls aged 0 to ten years with a closed, completely displaced metaphyseal distal radial fracture presented between 1 November 2015 and 1 January 2020. After 2018, children aged ten or under were offered treatment in a straight plaster or manipulation under anaesthesia with Kirschner (K-)wire stabilization. Case notes and radiographs were reviewed to evaluate outcomes. In all, 16 underwent treatment in a straight cast and 40 had manipulation under anaesthesia, including 37 stabilized with K-wires. Results. Of the children treated in a straight cast, all were discharged with good range of mo (ROM). Five children were discharged at six to 12 weeks with no functional limitations at six-month follow-up. A total of 11 children were discharged between 12 and 50 weeks with a normal ROM and radiological evidence of remodelling. One child had a subsequent diaphyseal fracture proximal to the original injury four years after the initial fracture. Re-displacement with angulation greater than 10° occurred for 17 children who had manipulation under anaesthesia. Four had a visible cosmetic deformity at discharge and nine had restriction of movement, with four requiring physiotherapy. One child developed over- granulation at the pin site and one wire became buried, resulting in a difficult retrieval in clinic. No children had pin site infections. Conclusion. Nonoperative management of completely displaced distal radial fractures in appropriately selected cases results in excellent outcomes without exposing the child to the risks of surgery. This study suggests that nonoperative management of these injuries is a viable and potentially underused strategy. Cite this article: Bone Joint J 2021;103-B(5):902–907


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 286 - 293
1 Feb 2021
Park CH Yan H Park J

Aims. No randomized comparative study has compared the extensile lateral approach (ELA) and sinus tarsi approach (STA) for Sanders type 2 calcaneal fractures. This randomized comparative study was conducted to confirm whether the STA was prone to fewer wound complications than the ELA. Methods. Between August 2013 and August 2018, 64 patients with Sanders type 2 calcaneus fractures were randomly assigned to receive surgical treatment by the ELA (32 patients) and STA (32 patients). The primary outcome was development of wound complications. The secondary outcomes were postoperative complications, pain scored of a visual analogue scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score, 36-item Short Form health survey, operative duration, subtalar joint range of motion (ROM), Böhler’s angle and calcaneal width, and posterior facet reduction. Results. Although four patients (12.5%) in the ELA groups and none in the STA group experienced complications, the difference was not statistically significant (p = 0.113). VAS and AOFAS score were significantly better in the STA group than in the ELA group at six months (p = 0.017 and p = 0.021), but not at 12 months (p = 0.096 and p = 0.200) after surgery. The operation time was significantly shorter in the STA group than in the ELA group (p < 0.001). The subtalar joint ROM was significantly better in the STA group (p = 0.015). Assessment of the amount of postoperative reduction compared with the uninjured limb showed significant restoration of calcaneal width in the ELA group compared with that in the STA group (p < 0.001). Conclusion. The ELA group showed higher frequency of wound complications than the STA group for Sanders type 2 calcaneal fractures even though this was not statistically significant. Cite this article: Bone Joint J 2021;103-B(2):286–293


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 838 - 847
1 Jul 2019
Robinson PG Clement ND Hamilton D Blyth MJG Haddad FS Patton JT

Aims. Robotic-assisted unicompartmental knee arthroplasty (UKA) promises accurate implant placement with the potential of improved survival and functional outcomes. The aim of this study was to present the current evidence for robotic-assisted UKA and describe the outcome in terms of implant positioning, range of movement (ROM), function and survival, and the types of robot and implants that are currently used. Materials and Methods. A search of PubMed and Medline was performed in October 2018 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “knee”, and “surgery”. The criteria for inclusion was any study describing the use of robotic UKA and reporting implant positioning, ROM, function, and survival for clinical, cadaveric, or dry bone studies. Results. A total of 528 articles were initially identified from the databases and reference lists. Following full text screening, 38 studies that satisfied the inclusion criteria were included. In all, 20 studies reported on implant positioning, 18 on functional outcomes, 16 on survivorship, and six on ROM. The Mako (Stryker, Mahwah, New Jersey) robot was used in 32 studies (84%), the BlueBelt Navio (Blue Belt Technologies, Plymouth, Minnesota) in three (8%), the Sculptor RGA (Stanmore Implants, Borehamwood United Kingdom) in two (5%), and the Acrobot (The Acrobot Co. Ltd., London, United Kingdom) in one study (3%). The most commonly used implant was the Restoris MCK (Stryker). Nine studies (24%) did not report the implant that was used. The pooled survivorship at six years follow-up was 96%. However, when assessing survival according to implant design, survivorship of an inlay (all-polyethylene) tibial implant was 89%, whereas that of an onlay (metal-backed) implant was 97% at six years (odds ratio 3.66, 95% confidence interval 20.7 to 6.46, p < 0.001). Conclusion. There is little description of the choice of implant when reporting robotic-assisted UKA, which is essential when assessing survivorship, in the literature. Implant positioning with robotic-assisted UKA is more accurate and more reproducible than that performed manually and may offer better functional outcomes, but whether this translates into improved implant survival in the mid- to longer-term remains to be seen. Cite this article: Bone Joint J 2019;101-B:838–847


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1697 - 1702
1 Dec 2020
Schormans PMJ Kooijman MA Ten Bosch JA Poeze M Hannemann PFW

Aims. Fixation of scaphoid nonunion with a volar locking plate and cancellous bone grafting has been shown to be a successful technique in small series. Few mid- or long-term follow-up studies have been reported. The aim of this study was to report the mid-term radiological and functional outcome of plate fixation for scaphoid nonunion. Methods. Patients with a scaphoid nonunion were prospectively enrolled and treated with open reduction using a volar approach, debridement of the nonunion, and fixation using a locking plate and cancellous bone grafting, from the ipsilateral iliac crest. Follow-up included examination, functional assessment using the patient-rated wrist/hand evaluation (PRWHE), and multiplanar reformation CT scans at three-month intervals until union was confirmed. Results. A total of 49 patients with a mean age of 31 years (16 to 74) and a mean duration of nonunion of 3.6 years (0.4 to 16) were included. Postoperatively, the nonunion healed in 47 patients (96%) as shown on CT scans. The mean time to union was 4.2 months (3 to 12). Due to impingement of the plate on the volar rim of the radius and functional limitation, the hardware was removed in 18 patients. At a median follow-up of 38 months in 34 patients, the mean active range of motion (ROM) improved significantly from 89° to 124° (SD 44°; p = 0.003). The mean grip strength improved significantly from 52% to 79% (SD 28%; p < 0.001) of the contralateral side. The mean PRWHE score improved significantly from 66 to 17 points (SD 25; p < 0.001). Conclusion. Locking plate fixation supplemented with autologous cancellous bone grafting is a successful form of treatment for scaphoid nonunion. Functional outcomes improve with the passage of time, and mid-term results are excellent with a significant improvement in ROM, grip strength, and functional outcome as measured by the PRWHE. Cite this article: Bone Joint J 2020;102-B(12):1697–1702


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1331 - 1340
3 Oct 2020
Attard V Li CY Self A Mann DA Borthwick LA O’Connor P Deehan DJ Kalson NS

Aims. Stiffness is a common complication after total knee arthroplasty (TKA). Pathogenesis is not understood, treatment options are limited, and diagnosis is challenging. The aim of this study was to investigate if MRI can be used to visualize intra-articular scarring in patients with stiff, painful knee arthroplasties. Methods. Well-functioning primary TKAs (n = 11), failed non-fibrotic TKAs (n = 5), and patients with a clinical diagnosis of fibrosis. 1. (n = 8) underwent an MRI scan with advanced metal suppression (Slice Encoding for Metal Artefact Correction, SEMAC) with gadolinium contrast. Fibrotic tissue (low intensity on T1 and T2, low-moderate post-contrast enhancement) was quantified (presence and tissue thickness) in six compartments: supra/infrapatella, medial/lateral gutters, and posterior medial/lateral. Results. Fibrotic tissue was identified in all patients studied. However, tissue was significantly thicker in fibrotic patients (4.4 mm ± 0.2 mm) versus non-fibrotic (2.5 mm ± 0.4 mm) and normal TKAs (1.9 mm ± 0.2 mm, p = < 0.05). Significant (> 4 mm thick) tissue was seen in 26/48 (54%) of compartments examined in the fibrotic group, compared with 17/30 (57%) non-fibrotic, and 10/66 (15%) normal TKAs. Although revision surgery did improve range of movement (ROM) in all fibrotic patients, clinically significant restriction remained post-surgery. Conclusion. Stiff TKAs contain intra-articular fibrotic tissue that is identifiable by MRI. Studies should evaluate whether MRI is useful for surgical planning of debridement, and as a non-invasive measurement tool following interventions for stiffness caused by fibrosis. Revision for stiffness can improve ROM, but outcomes are sub-optimal and new treatments are required. Cite this article: Bone Joint J 2020;102-B(10):1331–1340


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 129 - 134
1 Jul 2021
Ayekoloye CI Abu Qa'oud M Radi M Leon SA Kuzyk P Safir O Gross AE

Aims. Improvements in functional results and long-term survival are variable following conversion of hip fusion to total hip arthroplasty (THA) and complications are high. The aim of the study was to analyze the clinical and functional results in patients who underwent conversion of hip fusion to THA using a consistent technique and uncemented implants. Methods. A total of 39 hip fusion conversions to THA were undertaken in 38 patients by a single surgeon employing a consistent surgical technique and uncemented implants. Parameters assessed included Harris Hip Score (HHS) for function, range of motion (ROM), leg length discrepancy (LLD), satisfaction, and use of walking aid. Radiographs were reviewed for loosening, subsidence, and heterotopic ossification (HO). Postoperative complications and implant survival were assessed. Results. At mean 12.2 years (2 to 24) follow-up, HHS improved from mean 34.2 (20.8 to 60.5) to 75 (53.6 to 94.0; p < 0.001). Mean postoperative ROM was flexion 77° (50° to 95°), abduction 30° (10° to 40°), adduction 20° (5° to 25°), internal rotation 18° (2° to 30°), and external rotation 17° (5° to 30°). LLD improved from mean -3.36 cm (0 to 8) to postoperative mean -1.14 cm (0 to 4; p < 0.001). Postoperatively, 26 patients (68.4%) required the use of a walking aid. Complications included one (2.5%) dislocation, two (5.1%) partial sciatic nerve injuries, one (2.5%) deep periprosthetic joint infection, two instances of (5.1%) acetabular component aseptic loosening, two (5.1%) periprosthetic fractures, and ten instances of HO (40%), of which three (7.7%) were functionally limiting and required excision. Kaplan-Meier Survival was 97.1% (95% confidence interval (CI) 91.4% to 100%) at ten years and 88.2% (95% CI 70.96 to 100) at 15 years with implant revision for aseptic loosening as endpoint and 81.7% (95% CI 70.9% to 98.0%) at ten years and 74.2% (95% CI 55.6 to 92.8) at 15 years follow-up with implant revision for all cause failure as endpoint. Conclusion. The use of an optimal and consistent surgical technique and cementless implants can result in significant functional improvement, low complication rates, long-term implant survival, and high patient satisfaction following conversion of hip fusion to THA. The possibility of requiring a walking aid should be discussed with the patient before surgery. Cite this article: Bone Joint J 2021;103-B(7 Supple B):129–134


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 852 - 860
1 Jul 2020
Zamora T Garbuz DS Greidanus NV Masri BA

Aims. Our objective is to describe our early and mid-term results with the use of a new simple primary knee prosthesis as an articulating spacer in planned two-stage management for infected knee arthroplasty. As a second objective, we compared outcomes between the group with a retained first stage and those with a complete two-stage revision. Methods. We included 47 patients (48 knees) with positive criteria for infection, with a minimum two-year follow-up, in which a two-stage approach with an articulating spacer with new implants was used. Patients with infection control, and a stable and functional knee were allowed to retain the initial first-stage components. Outcomes recorded included: infection control rate, reoperations, final range of motion (ROM), and quality of life assessment (QoL) including Western Ontario and McMaster Universities osteoarthritis index, Knee Injury and Osteoarthritis Outcome Score, Oxford Knee Score, 12-Item Short-Form Health Survey questionnaire, and University of California Los Angeles (UCLA) activity score and satisfaction score. These outcomes were evaluated and compared to additional cohorts of patients with retained first-stage interventions and those with a complete two-stage revision. Mean follow-up was 3.7 years (2.0 to 6.5). Results. Eight knees failed directly related to lack of infection control (16%), and two patients (two knees) died within the first year for causes not directly related, giving an initial success rate of 79% (38/48). Secondary success rate after a subsequent procedure was 91% (44/48 knees). From the initially retained spacers, four knees (22%) required a second-stage revision for continuous symptoms and one (5%) for an acute infection. There were no significant differences regarding the failure rate due to infection, ROM, and QoL assessment between patients with a retained first-stage procedure and those who underwent a second-stage operation. Conclusion. Our protocol of two-stage exchange for infected knee arthroplasties with an articulating spacer and using new primary knee implants achieves adequate infection control. Retained first-stage operations achieve comparable results in selected cases, with no difference in infection control, ROM, and QoL assessment in comparison to patients with completed two-stage revision surgery. Cite this article: Bone Joint J 2020;102-B(7):852–860


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 68 - 72
1 Jan 2011
Motosuneya T Maruyama T Yamada H Tsuzuki N Sakai H

We reviewed 75 patients (57 men and 18 women), who had undergone tension-band laminoplasty for cervical spondylotic myelopathy (42 patients) or compression myelopathy due to ossification of the posterior longitudinal ligament (33 patients) and had been followed for more than ten years. Clinical and functional results were estimated using the Japanese Orthopaedic Association score. The rate of recovery and the level of postoperative axial neck pain were also recorded. The pre- and post-operative alignment of the cervical spine (Ishihara curve index indicating lordosis of the cervical spine) and the range of movement (ROM) of the cervical spine were also measured. The mean rate of recovery of the Japanese Orthopaedic Association score at final follow-up was 52.1% (. sd. 24.6) and significant axial pain was reported by 19 patients (25.3%). Axial pain was reported more frequently in patients with ossification of the posterior longitudinal ligament than in those with cervical spondylotic myelopathy (p = 0.027). A kyphotic deformity was not seen post-operatively in any patient. The mean ROM decreased post-operatively from 32.8° (. sd. 12.3) to 16.2° (. sd. 12.3) (p < 0.001). The mean ROM ratio was 46.9% (. sd. 28.1) for all the patients. The mean ROM ratio was lower in patients with ossification of the posterior longitudinal ligament than in those with cervical spondylotic myelopathy (p < 0.001). Compared to those with cervical spondylotic myelopathy, patients with ossification of the posterior longitudinal ligament had less ROM and more post-operative axial neck pain


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 129 - 132
1 Nov 2013
Berend KR Lombardi Jr AV Adams JB

Debate has raged over whether a cruciate retaining (CR) or a posterior stabilised (PS) total knee replacement (TKR) provides a better range of movement (ROM) for patients. Various sub-sets of CR design are frequently lumped together when comparing outcomes. Additionally, multiple factors have been proven to influence the rate of manipulation under anaesthetic (MUA) following TKR. The purpose of this study was to determine whether different CR bearing insert designs provide better ROM or different MUA rates. All primary TKRs performed by two surgeons between March 2006 and March 2009 were reviewed and 2449 CR-TKRs were identified. The same CR femoral component, instrumentation, and tibial base plate were consistently used. In 1334 TKRs a CR tibial insert with 3° posterior slope and no posterior lip was used (CR-S). In 803 there was an insert with no slope and a small posterior lip (CR-L) and in 312 knees the posterior cruciate ligament (PCL) was either resected or lax and a deep-dish, anterior stabilised insert was used (CR-AS). More CR-AS inserts were used in patients with less pre-operative ROM and greater pre-operative tibiofemoral deformity and flexion contracture (p < 0.05). The mean improvement in ROM was highest for the CR-AS inserts (5.9° (-40° to 55°) vs CR-S 3.1° (-45° to 70°) vs CR-L 3.0° (-45° to 65°); p = 0.004). There was a significantly higher MUA rate with the CR-S and CR-L inserts than CR-AS (Pearson rank 6.51; p = 0.04). Despite sacrificing or not substituting for the PCL, ROM improvement was highest, and the MUA rate was lowest in TKRs with a deep-dish, anterior-stabilised insert. Substitution for the posterior cruciate ligament (PCL) in the form of a PS design may not be necessary even when the PCL is deficient. . Cite this article: Bone Joint J 2013;95-B, Supple A:129–32


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 632 - 637
1 May 2020
Gonzalez LJ Hildebrandt K Carlock K Konda SR Egol KA

Aims. Tibial plateau fractures are serious injuries about the knee that have the potential to affect patients’ long-term function. To our knowledge, this is the first study to use patient-reported outcomes (PROs) with a musculoskeletal focus to assess the long-term outcome, as compared to a short-term outcome baseline, of tibial plateau fractures treated using modern techniques. Methods. In total, 102 patients who sustained a displaced tibial plateau fracture and underwent operative repair by one of three orthopaedic traumatologists at a large, academic medical centre and had a minimum of five-year follow-up were identified. Breakdown of patients by Schatzker classification is as follows: two (1.9%) Schatzker I, 54 (50.9%) Schatzker II, two (1.9%) Schatzker III, 13 (12.3%) Schatzker IV, nine (8.5%) Schatzker V, and 26 (24.5%) Schatzker VI. Follow-up data obtained included: Visual Analogue Scale (VAS) or Numeric Rating Scale (NRS) pain scores, Short Musculoskeletal Functional Assessment (SMFA), and knee range of movement (ROM). Data at latest follow-up were then compared to 12-month data using a paired t-test. Results. Patient-reported functional outcomes as assessed by overall SMFA were statistically significantly improved at five years (p < 0.001) compared with one-year data from the same patients. Patients additionally reported an improvement in the Standardized Mobility Index (p < 0.001), Standardized Emotional Index (p < 0.001), as well as improvement in Standardized Bothersome Index (p = 0.003) between the first year and latest follow-up. Patient-reported pain and knee ROM were similar at five years to their one-year follow-up. In total, 15 of the patients had undergone subsequent orthopaedic surgery for their knees at the time of most recent follow-up. Of note, only one patient had undergone knee arthroplasty following plateau fixation related to post-traumatic osteoarthritis (OA). Conclusion. Knee pain following tibial plateau fracture stabilizes at one year. However, PROs continue to improve beyond one year following tibial plateau fracture, at least in a statistical sense, if not also clinically. Patients displayed statistical improvement across nearly all SMFA index scores at their minimum five-year follow-up compared with their one-year follow-up. Cite this article: Bone Joint J 2020;102-B(5):632–637


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1168 - 1176
1 Sep 2019
Calder PR McKay JE Timms AJ Roskrow T Fugazzotto S Edel P Goodier WD

Aims. The Precice intramedullary limb-lengthening system has demonstrated significant benefits over external fixation lengthening methods, leading to a paradigm shift in limb lengthening. This study compares outcomes following antegrade and retrograde femoral lengthening in both adolescent and adult patients. Patients and Methods. A retrospective review of prospectively collected data was undertaken of a consecutive series of 107 femoral lengthening operations in 92 patients. In total, 73 antegrade nails and 34 retrograde nails were inserted. Outcome was assessed by the regenerate healing index (HI), hip and knee range of movement (ROM), and the presence of any complications. Results. The mean lengthening was 4.65 cm (1.5 to 8) in the antegrade group and 4.64 cm (1.6 to 8) in the retrograde group. Of the 107 lengthenings, 100 had sufficient datapoints to calculate the mean HI. This was 31.6 days/cm (15 to 108). There was a trend toward a lower (better) HI with an antegrade nail and better outcomes in adolescent patients, but these were not statistically significant. Hip and knee ROM was maintained and/or improved following commencement of femoral lengthening in 44 patients (60%) of antegrade nails and 13 patients (38%) of retrograde nails. In female patients, loss of movement occurred both earlier and following less total length achieved. Minor implant complications included locking bolt migration and in one patient deformity of the nail, but no implant failed to lengthen and there were no deep infections. Three patients had delayed union, five patients required surgical intervention for joint contracture. Conclusion. This study confirms excellent results in femoral lengthening with antegrade and retrograde Precice nails. There is a trend for better healing and less restriction in hip and knee movement following antegrade nails. There are clinical scenarios, that mandate the use of a retrograde nail. However, when these are not present, we recommend the use of antegrade nailing. Cite this article: Bone Joint J 2019;101-B:1168–1176


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 559 - 564
1 May 2019
Takemura S Minoda Y Sugama R Ohta Y Nakamura S Ueyama H Nakamura H

Aims. The use of vitamin E-infused highly crosslinked polyethylene (HXLPE) in total knee prostheses is controversial. In this paper we have compared the clinical and radiological results between conventional polyethylene and vitamin E-infused HXLPE inserts in total knee arthroplasty (TKA). Patients and Methods. The study included 200 knees (175 patients) that underwent TKA using the same total knee prostheses. In all, 100 knees (77 patients) had a vitamin E-infused HXLPE insert (study group) and 100 knees (98 patients) had a conventional polyethylene insert (control group). There were no significant differences in age, sex, diagnosis, preoperative knee range of movement (ROM), and preoperative Knee Society Score (KSS) between the two groups. Clinical and radiological results were evaluated at two years postoperatively. Results. Differences in postoperative ROM and KSS were not statistically significant between the study and control groups. No knee exhibited osteolysis, aseptic loosening, or polyethylene failure. Additionally, there was no significant difference in the incidence of a radiolucent line between the two groups. One patient from the study group required irrigation and debridement, due to deep infection, at six months postoperatively. Conclusion. Clinical results were comparable between vitamin E-infused HXLPE inserts and conventional polyethylene inserts at two years after TKA, without any significant clinical failure. Cite this article: Bone Joint J 2019;101-B:559–564


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 890 - 898
1 Jul 2015
Renkawitz T Weber M Springorum H Sendtner E Woerner M Ulm K Weber T Grifka J

We report the kinematic and early clinical results of a patient- and observer-blinded randomised controlled trial in which CT scans were used to compare potential impingement-free range of movement (ROM) and acetabular component cover between patients treated with either the navigated ‘femur-first’ total hip arthroplasty (THA) method (n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75). The Hip Osteoarthritis Outcome Score, the Harris hip score, the Euro-Qol-5D and the Mancuso THA patient expectations score were assessed at six weeks, six months and one year after surgery. A total of 48 of the patients (84%) in the navigated ‘femur-first’ group and 43 (65%) in the conventional group reached all the desirable potential ROM boundaries without prosthetic impingement for activities of daily living (ADL) in flexion, extension, abduction, adduction and rotation (p = 0.016). Acetabular component cover and surface contact with the host bone were > 87% in both groups. There was a significant difference between the navigated and the conventional groups’ Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated ‘femur-first’ technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups. Cite this article: Bone Joint J 2015; 97-B:890–8


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1640 - 1644
1 Dec 2015
Dzaja I Vasarhelyi EM Lanting BA Naudie DD Howard JL Somerville L McCalden RW MacDonald SJ

The purpose of this study was to compare clinical outcomes of total knee arthroplasty (TKA) after manipulation under anaesthesia (MUA) for post-operative stiffness with a matched cohort of TKA patients who did not requre MUA. . In total 72 patients (mean age 59.8 years, 42 to 83) who underwent MUA following TKA were identified from our prospective database and compared with a matched cohort of patients who had undergone TKA without subsequent MUA. Patients were evaluated for range of movement (ROM) and clinical outcome scores (Western Ontario and McMaster Universities Arthritis Index, Short-Form Health Survey, and Knee Society Clinical Rating System) at a mean follow-up of 36.4 months (12 to 120). MUA took place at a mean of nine weeks (5 to 18) after TKA. In patients who required MUA, mean flexion deformity improved from 10° (0° to 25°) to 4.4° (0° to 15°) (p < 0.001), and mean range of flexion improved from 79.8° (65° to 95°) to 116° (80° to 130°) (p < 0.001). There were no statistically significant differences in ROM or functional outcome scores at three months, one year, or two years between those who required MUA and those who did not. There were no complications associated with manipulation. At most recent follow-up, patients requiring MUA achieved equivalent ROM and clinical outcome scores when compared with a matched control group. While other studies have focused on ROM after manipulation, the current study adds to current literature by supplementing this with functional outcome scores. Cite this article: Bone Joint J 2015;97-B:1640–4


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1086 - 1092
1 Aug 2016
de Vos MJ Wagener ML Hannink G van der Pluijm M Verdonschot N Eygendaal D

Aims. Revision total elbow arthroplasty (TEA) is often challenging. The aim of this study was to report on the clinical and radiological results of revision arthroplasty of the elbow with the Latitude TEA. Patients and Methods. Between 2006 and 2010 we used the Latitude TEA for revision in 18 consecutive elbows (17 patients); mean age 53 years (28 to 80); 14 women. A Kudo TEA was revised in 15 elbows and a Souter-Strathclyde TEA in three. Stability, range of movement (ROM), visual analogue score (VAS) for pain and functional scores, Elbow Functional Assessment Scale (EFAS), the Functional Rating Index of Broberg and Morrey (FRIBM) and the Modified Andrews’ Elbow Scoring System (MAESS) were assessed pre-operatively and at each post-operative follow-up visit (six, 12 months and biennially thereafter). Radiographs were analysed for loosening, fractures and dislocation. The mean follow-up was 59 months (26 to 89). Results. The ROM of the elbow did not improve significantly. The mean EFAS and MAESS scores improved significantly six months post-operatively (18.6 points, standard deviation (. sd. ) 7.7; p = 0.03 and 28.8 points, . sd . 8.6; p = 0.006, respectively) and continued to improve slightly or reached a plateau. The mean pain scores at rest (Z = -3.2, p = 0.001) and during activity (Z = -3.2, p = 0.001), and stability (Z = -3.0, p = 0.003) improved significantly six months post-operatively. Thereafter scores continued to improve slightly or a plateau was reached. There were no signs of loosening. Conclusion. Revision surgery using the Latitude TEA results in improvement of functionality, reduced pain and better stability of the elbow. Improvement of ROM of the elbow should not be expected. Cite this article: Bone Joint J 2016;98-B:1086–92


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 804 - 808
1 Jun 2005
Matsuda Y Ishii Y Noguchi H Ishii R

We performed a randomised, prospective study of 80 mobile-bearing total knee arthroplasties (80 knees) in order to measure the effects of varus-valgus laxity and balance on the range of movement (ROM) one year after operation. Forty knees had a posterior-cruciate-ligament (PCL)-retaining prosthesis and the other 40 a PCL-sacrificing prosthesis. In the balanced group (69 knees) in which the difference between varus and valgus was less than 2°, the mean ROM improved significantly from 107.6° to 117.7° (p < 0.0001). By contrast, in the 11 knees which were unbalanced and in which the difference between varus and valgus laxity exceeded 2°, the ROM decreased from a mean of 121.0° to 112.7° (p = 0.0061). We conclude that coronal laxity, especially balanced laxity, is important for achieving an improved ROM in mobile-bearing total knee arthroplasty


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 77 - 83
1 Jul 2019
James EW Blevins JL Gausden EB Turcan S Denova TA Satalich JR Ranawat AS Warren RF Ranawat AS

Aims. Anterior cruciate ligament (ACL) and multiligament knee (MLK) injuries increase the risk of development of knee osteoarthritis and eventual need for total knee arthroplasty (TKA). There are limited data regarding implant use and outcomes in these patients. The aim of this study was to compare the use of constrained implants and outcomes among patients undergoing TKA with a history of prior knee ligament reconstruction (PKLR) versus a matched cohort of patients undergoing TKA with no history of PKLR. Patients and Methods. Patients with a history of ACL or MLK reconstruction who underwent TKA between 2007 and 2017 were identified in a single-institution registry. There were 223 patients who met inclusion criteria (188 ACL reconstruction patients, 35 MLK reconstruction patients). A matched cohort, also of 223 patients, was identified based on patient age, body mass index (BMI), sex, and year of surgery. There were 144 male patients and 79 female patients in both cohorts. Mean age at the time of TKA was 57.2 years (31 to 88). Mean BMI was 29.7 kg/m. 2. (19.5 to 55.7). Results. There was a significantly higher use of constrained implants among patients with PKLR (76 of 223, 34.1%) compared with the control group (40 of 223, 17.9%; p < 0.001). Subgroup analysis showed a higher use of constrained implants among patients with prior MLK reconstruction (21 of 35, 60.0%) compared with ACL reconstruction (55 of 188, 29.3%; p < 0.001). Removal of hardware was performed in 69.5% of patients with PKLR. Mean operative time (p < 0.001) and tourniquet time (p < 0.001) were longer in patients with PKLR compared with controls. There were no significant differences in rates of deep vein thrombosis, pulmonary embolism, infection, transfusion, postoperative knee range of movement (ROM), or need for revision surgery. There was no significant difference in preoperative or postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR) scores between groups. Conclusion. Results of this study suggest a history of PKLR results in increased use of constrained implants but no difference in postoperative knee ROM, patient-reported outcomes, or incidence of revision surgery. Cite this article: Bone Joint J 2019;101-B(7 Supple C):77–83


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 458 - 462
1 Apr 2020
Limberg AK Tibbo ME Pagnano MW Perry KI Hanssen AD Abdel MP

Aims. Varus-valgus constrained (VVC) implants are often used during revision total knee arthroplasty (TKA) to gain coronal plane stability. However, the increased mechanical torque applied to the bone-cement interface theoretically increases the risk of aseptic loosening. We assessed mid-term survivorship, complications, and clinical outcomes of a fixed-bearing VVC device in revision TKAs. Methods. A total of 416 consecutive revision TKAs (398 patients) were performed at our institution using a single fixed-bearing VVC TKA from 2007 to 2015. Mean age was 64 years (33 to 88) with 50% male (199). Index revision TKA diagnoses were: instability (n = 122, 29%), aseptic loosening (n = 105, 25%), and prosthetic joint infection (PJI) (n = 97, 23%). All devices were cemented on the epiphyseal surfaces. Femoral stems were used in 97% (n = 402) of cases, tibial stems in 95% (n = 394) of cases; all were cemented. In total, 93% (n = 389) of cases required a stemmed femoral and tibial component. Femoral cones were used in 29%, and tibial cones in 40%. Survivorship was assessed via competing risk analysis; clinical outcomes were determined using Knee Society Scores (KSSs) and range of movement (ROM). Mean follow-up was four years (2 to 10). Results. The five-year cumulative incidence of subsequent revision for aseptic loosening and instability were 2% (95% confidence interval (CI) 0.2 to 3, number at risk = 154) and 4% (95% CI 2 to 6, number at risk = 153), respectively. The five-year cumulative incidence of any subsequent revision was 14% (95% CI 10 to 18, number at risk = 150). Reasons for subsequent revision included PJI (n = 23, of whom 12 had previous PJI), instability (n = 13), and aseptic loosening (n = 11). The use of this implant without stems was found to be a significant risk factor for subsequent revision (hazard ratio (HR) 7.58 (95% CI 3.98 to 16.03); p = 0.007). KSS improved from 46 preoperatively to 81 at latest follow-up (p < 0.001). ROM improved from 96° prerevision to 108° at latest follow-up (p = 0.016). Conclusion. The cumulative incidence of subsequent revision for aseptic loosening and instability was very low at five years with this fixed-bearing VVC implant in revision TKAs. Routine use of cemented and stemmed components with targeted use of metaphyseal cones likely contributed to this low rate of aseptic loosening. Cite this article: Bone Joint J 2020;102-B(4):458–462


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 153 - 156
1 Nov 2012
Su EP Perna M Boettner F Mayman DJ Gerlinger T Barsoum W Randolph J Lee G

Pain, swelling and inflammation are expected during the recovery from total knee arthroplasty (TKA) surgery. The severity of these factors and how a patient copes with them may determine the ultimate outcome of a TKA. Cryotherapy and compression are frequently used modalities to mitigate these commonly experienced sequelae. However, their effect on range of motion, functional testing, and narcotic consumption has not been well-studied. A prospective, multi-center, randomised trial was conducted to evaluate the effect of a cryopneumatic device on post-operative TKA recovery. Patients were randomised to treatment with a cryopneumatic device or ice with static compression. A total of 280 patients were enrolled at 11 international sites. Both treatments were initiated within three hours post-operation and used at least four times per day for two weeks. The cryopneumatic device was titrated for cooling and pressure by the patient to their comfort level. Patients were evaluated by physical therapists blinded to the treatment arm. Range of motion (ROM), knee girth, six minute walk test (6MWT) and timed up and go test (TUG) were measured pre-operatively, two- and six-weeks post-operatively. A visual analog pain score and narcotic consumption was also measured post-operatively. At two weeks post-operatively, both the treatment and control groups had diminished ROM and function compared to pre-operatively. Both groups had increased knee girth compared to pre- operatively. There was no significant difference in ROM, 6MWT, TUG, or knee girth between the 2 groups. We did find a significantly lower amount of narcotic consumption (509 mg morphine equivalents) in the treatment group compared with the control group (680 mg morphine equivalents) at up to two weeks postop, when the cryopneumatic device was being used (p < 0.05). Between two and six weeks, there was no difference in the total amount of narcotics consumed between the two groups. At six weeks, there was a trend toward a greater distance walked in the 6MWT in the treatment group (29.4 meters versus 7.9 meters, p = 0.13). There was a significant difference in the satisfaction scores of patients with their cooling regimen, with greater satisfaction in the treatment group (p < 0.0001). There was no difference in ROM, TUG, VAS, or knee girth at six weeks. There was no difference in adverse events or compliance between the two groups. A cryopneumatic device used after TKA appeared to decrease the need for narcotic medication from hospital discharge to 2 weeks post-operatively. There was also a trend toward a greater distance walked in the 6MWT. Patient satisfaction with the cryopneumatic cooling regimen was significantly higher than with the control treatment.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 210 - 216
1 Feb 2014
Hanusch BC O’Connor DB Ions P Scott A Gregg PJ

This cohort study investigated the influence of psychological factors, including perception of illness, anxiety and depression on recovery and functional outcome after total knee replacement surgery. . A total of 100 patients (55 male; 45 female) with a mean age of 71 (42 to 92) who underwent a primary total knee replacement for osteoarthritis were recruited into this study. In all 97 participants completed the six week and 87 the one year follow-up questionnaires. . Pre-operatively patients completed the revised Illness Perception Questionnaire, Hospital Anxiety and Depression Scale and Recovery Locus of Control Scale. Function was assessed pre-operatively, at six weeks and one year using Oxford Knee Score (OKS) and the goniometer-measured range of movement (ROM). . The results showed that pre-operative function had the biggest impact on post-operative outcome for ROM and OKS. In addition questionnaire variables and depression had an impact on the OKS at six weeks. Depression and anxiety were also associated with a higher (worse) knee score at one year but did not influence the ROM at either six weeks or one year. Recovery from total knee replacement can be difficult to predict. This study has identified psychological factors that play an important role in recovery from surgery and functional outcome. These should be taken into account when considering patients for total knee replacement. Cite this article: Bone Joint J 2014;96-B:210–16


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 455 - 464
15 Mar 2023
de Joode SGCJ Meijer R Samijo S Heymans MJLF Chen N van Rhijn LW Schotanus MGM

Aims

Multiple secondary surgical procedures of the shoulder, such as soft-tissue releases, tendon transfers, and osteotomies, are described in brachial plexus birth palsy (BPBP) patients. The long-term functional outcomes of these procedures described in the literature are inconclusive. We aimed to analyze the literature looking for a consensus on treatment options.

Methods

A systematic literature search in healthcare databases (PubMed, Embase, the Cochrane library, CINAHL, and Web of Science) was performed from January 2000 to July 2020, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. The quality of the included studies was assessed with the Cochrane ROBINS-I risk of bias tool. Relevant trials studying BPBP with at least five years of follow-up and describing functional outcome were included.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 213 - 220
1 Feb 2019
Xu S Lim WJ Chen JY Lo NN Chia S Tay DKJ Hao Y Yeo SJ

Aims. The aim of this study was to assess the influence of obesity on the clinical outcomes and survivorship ten years postoperatively in patients who underwent a fixed-bearing unicompartmental knee arthroplasty (UKA). Patients and Methods. We prospectively followed 184 patients who underwent UKA between 2003 and 2007 for a minimum of ten years. A total of 142 patients with preoperative body mass index (BMI) of < 30 kg/m. 2. were in the control group (32 male, 110 female) and 42 patients with BMI of ≥ 30 kg/m. 2. were in the obese group (five male, 37 female). Pre- and postoperative range of movement (ROM), Knee Society Score (KSS), Oxford Knee Score (OKS), 36-Item Short-Form Health Survey (SF-36), and survivorship were analyzed. Results. Patients in the obese group underwent UKA at a significantly younger mean age (56.5 years (. sd. 6.4)) than those in the control group (62.4 years (. sd. 7.8); p < 0.001). There was no significant difference in preoperative functional scores. However, those in the obese group had a significantly lower ROM (116° (. sd. 15°) vs 123° (. sd. 17°); p = 0.003). Both groups achieved significant improvement in outcome scores regardless of BMI, ten years postoperatively. All patients achieved the minimal clinically important difference (MCID) for OKS and KSS. Both groups also had high rates of satisfaction (96.3% in the control group and 97.5% in the obese group) and the fulfilment of expectations (94.9% in the control group and 95.0% in the obese group). Multiple linear regression showed a clear association between obesity and a lower OKS two years postoperatively and Knee Society Function Score (KSFS) ten years postoperatively. After applying propensity matching, obese patients had a significantly lower KSFS, OKS, and physical component score (PCS) ten years postoperatively. Seven patients underwent revision to total knee arthroplasty (TKA), two in the control group and five in the obese group, resulting in a mean rate of survival at ten years of 98.6% and 88.1%, respectively (p = 0.012). Conclusion. Both groups had significant improvements in functional and quality-of-life scores postoperatively. However, obesity was a significant predictor of poorer improvement in clinical outcome and an increased rate of revision ten years postoperatively


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1329 - 1333
1 Dec 2022
Renfree KJ

This annotation reviews current concepts on the three most common surgical approaches used for proximal interphalangeal joint arthroplasty: dorsal, volar, and lateral. Advantages and disadvantages of each are highlighted, and the outcomes are discussed.

Cite this article: Bone Joint J 2022;104-B(12):1329–1333.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1263 - 1272
1 Nov 2024
Amador IE Hao KA Buchanan TR Damrow DS Hones KM Simcox T Schoch BS Farmer KW Wright TW LaMonica TJ King JJ Wright JO

Aims

We sought to compare functional outcomes and survival between non-smokers, former smokers, and current smokers who underwent anatomical total shoulder arthroplasty (aTSA) in a large cohort of patients.

Methods

A retrospective review of a prospectively collected shoulder arthroplasty database was performed between August 1991 and September 2020 to identify patients who underwent primary aTSA. Patients were excluded for preoperative diagnoses of fracture, infection, or oncological disease. Three cohorts were created based on smoking status: non-smokers, former smokers, and current smokers. Outcome scores (American Shoulder and Elbow Surgeons (ASES), Constant-Murley score, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), University of California, Los Angeles activity scale (UCLA)), range of motion (external rotation (ER), forward elevation (FE), internal rotation, abduction), and shoulder strength (ER, FE) evaluated at two- to four-year follow-up were compared between cohorts. Evaluation of revision-free survival was performed using the Kaplan-Meier method to final follow-up.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 925 - 929
1 Jul 2018
Abdel MP Tibbo ME Stuart MJ Trousdale RT Hanssen AD Pagnano MW

Aims. It has been suggested that mobile-bearing total knee arthroplasty (TKA) might lead to better outcomes by accommodating some femorotibial rotational mismatch, thereby reducing contact stresses and polyethylene wear. The aim of this study was to determine whether there is a difference between fixed- and mobile-bearing versions of a contemporary TKA with respect to durability, range of movement (ROM) and function, ten years postoperatively. Patients and Methods. A total of 240 patients who were enrolled in this randomized controlled trial (RCT) underwent a primary cemented TKA with one of three tibial components (all-polyethylene fixed-bearing, modular metal-backed fixed-bearing and mobile-bearing). Patients were reviewed at a median follow-up of ten years (IQR 9.2 to 10.4). Results. There was no difference in durability, as measured by survivorship free of revision for any reason, nor in mean maximal ROM at ten years (p = 0.8). There was also no difference in function, as measured by Knee Society (KS) function scores (p = 0.63) or the prevalence of patellar tilt (p = 0.12). Conclusion. In this clinical RCT, the mobile-bearing design of TKA was found to be reliable and durable, but did not provide better maximum knee flexion, function or durability ten years postoperatively compared with a posterior-stabilized, fixed-bearing design incorporating either an all-polyethylene or a modular-metal-backed tibial component. Cite this article: Bone Joint J 2018;100-B:925–9


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims

As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach.

Methods

A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 360 - 365
1 Feb 2021
Mahendraraj KA Shields MV Grubhofer F Golenbock SW Jawa A

Aims. Existing literature indicates that inferiorly inclined glenoid baseplates following reverse total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined baseplates. We aim to compare clinical outcomes for RSAs with superiorly and neutrally/inferiorly inclined lateralized glenospheres. Methods. We retrospectively reviewed 154 consecutive patients undergoing RSA between July 2015 and July 2017 by one single-fellowship trained surgeon (AJ). Two raters (KAM and MVS) independently measured glenoid inclination in preoperative and minimum two year follow-up radiographs (anteroposterior/Grashey) using the RSA angle. Inclination was then compared to patient-reported outcomes, range of motion (ROM), and independently assessed degree of scapular notching and staging of heterotopic ossification at two year follow-up. Results. Median postoperative inclination for each group was found to be -3.6° (interquartile range (IQR) -2.1 to -6.9) and 6.0° (3.2° to 10.1°) for the neutrally/inferiorly and superiorly inclined cohorts, respectively. Preoperative inclination was highly associated with postoperative inclination (p = 0.004). When comparing superiorly and neutrally/inferiorly inclined glenospheres, there were no differences in heterotopic ossification (p = 0.606), scapular notching (p = 0.367), American Shoulder and Elbow Surgeons score (p = 0.419), Single Assessment Numeric Evaluation (p = 0.417), Visual Analogue Scale (VAS) pain score (p = 0.290), forward elevation (p = 0.161), external rotation (p = 0.537), or internal rotation (p = 0.656). Conclusion. Compared to neutral and inferior inclination, up to 6° ± 3° of superior glenoid baseplate inclination on a lateralized RSA design produces no differences in postoperative ROM or patient-reported outcomes, and produces similar levels of scapular notching and heterotopic ossification. Additionally, the degree of preoperative inclination represents an important factor in surgical decision-making as it is strongly associated with postoperative inclination. It is important to note that the findings of this study are only reflective of lateralized RSA prostheses. Cite this article: Bone Joint J 2021;103-B(2):360–365


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 262 - 267
1 Mar 2024
de Villeneuve Bargemon J Mari R Mathoulin C Prenaud C Merlini L

Aims

Patients with midcarpal instability are difficult to manage. It is a rare condition, and few studies have reported the outcomes of surgical treatment. No prospective or retrospective study has reported the results of arthroscopic palmar capsuloligamentous suturing. Our aim was to report the results of a prospective study of arthroscopic suture of this ligament complex in patients with midcarpal instability.

Methods

This prospective single-centre study was undertaken between March 2012 and May 2022. The primary outcome was to evaluate the functional outcomes of arthroscopic palmar midcarpal suture. The study included 12 patients, eight male and four female, with a mean age of 27.5 years (19 to 42). They were reviewed at three months, six months, and one year postoperatively.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 635 - 640
1 Jun 2023
Karczewski D Siljander MP Larson DR Taunton MJ Lewallen DG Abdel MP

Aims

Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs.

Methods

A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m2 (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19).


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1327 - 1332
1 Nov 2024
Ameztoy Gallego J Diez Sanchez B Vaquero-Picado A Antuña S Barco R

Aims

In patients with a failed radial head arthroplasty (RHA), simple removal of the implant is an option. However, there is little information in the literature about the outcome of this procedure. The aim of this study was to review the mid-term clinical and radiological results, and the rate of complications and removal of the implant, in patients whose initial RHA was undertaken acutely for trauma involving the elbow.

Methods

A total of 11 patients in whom removal of a RHA without reimplantation was undertaken as a revision procedure were reviewed at a mean follow-up of 8.4 years (6 to 11). The range of motion (ROM) and stability of the elbow were recorded. Pain was assessed using a visual analogue scale (VAS). The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Radiological examination included the assessment of heterotopic ossification (HO), implant loosening, capitellar erosion, overlengthening, and osteoarthritis. Complications and the rate of further surgery were also recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1150 - 1157
1 Oct 2024
de Klerk HH Verweij LPE Doornberg JN Jaarsma RL Murase T Chen NC van den Bekerom MPJ

Aims

This study aimed to gather insights from elbow experts using the Delphi method to evaluate the influence of patient characteristics and fracture morphology on the choice between operative and nonoperative treatment for coronoid fractures.

Methods

A three-round electronic (e-)modified Delphi survey study was performed between March and December 2023. A total of 55 elbow surgeons from Asia, Australia, Europe, and North America participated, with 48 completing all questionnaires (87%). The panellists evaluated the factors identified as important in literature for treatment decision-making, using a Likert scale ranging from "strongly influences me to recommend nonoperative treatment" (1) to "strongly influences me to recommend operative treatment" (5). Factors achieving Likert scores ≤ 2.0 or ≥ 4.0 were deemed influential for treatment recommendation. Stable consensus is defined as an agreement of ≥ 80% in the second and third rounds.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 663 - 667
1 Jun 2023
Youn S Rhee SM Cho S Kim C Lee J Rhee YG

Aims

The aim of this study was to investigate the outcomes of arthroscopic decompression of calcific tendinitis performed without repairing the rotator cuff defect.

Methods

A total of 99 patients who underwent treatment between December 2013 and August 2019 were retrospectively reviewed. Visual analogue scale (VAS) and American Shoulder and Elbow Surgeons (ASES) scores were reviewed pre- and postoperatively according to the location, size, physical characteristics, and radiological features of the calcific deposits. Additionally, the influence of any residual calcific deposits shown on postoperative radiographs was explored. The healing rate of the unrepaired cuff defect was determined by reviewing the 29 patients who had follow-up MRIs.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 195 - 202
1 Feb 2024
Jamshidi K Kargar Shooroki K Ammar W Mirzaei A

Aims

The epiphyseal approach to a chondroblastoma of the intercondylar notch of a child’s distal femur does not provide adequate exposure, thereby necessitating the removal of a substantial amount of unaffected bone to expose the lesion. In this study, we compared the functional outcomes, local recurrence, and surgical complications of treating a chondroblastoma of the distal femoral epiphysis by either an intercondylar or an epiphyseal approach.

Methods

A total of 30 children with a chondroblastoma of the distal femur who had been treated by intraregional curettage and bone grafting were retrospectively reviewed. An intercondylar approach was used in 16 patients (group A) and an epiphyseal approach in 14 (group B). Limb function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and Sailhan’s functional criteria.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 957 - 963
1 Sep 2024
Baek CH Kim JG Kim BT

Aims

Favourable short-term outcomes have been reported following latissimus dorsi tendon transfer for patients with an irreparable subscapularis (SSC) tendon tear. The aim of this study was to investigate the long-term outcomes of this transfer in these patients.

Methods

This was a retrospective study involving 30 patients with an irreparable SSC tear and those with a SSC tear combined with a reparable supraspinatus tear, who underwent a latissimus dorsi tendon transfer. Clinical scores and active range of motion (aROM), SSC-specific physical examination and the rate of return to work were assessed. Radiological assessment included recording the acromiohumeral distance (AHD), the Hamada grade of cuff tear arthropathy and the integrity of the transferred tendon. Statistical analysis compared preoperative, short-term (two years), and final follow-up at a mean of 8.7 years (7 to 10).


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims

This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate.

Methods

We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view.


Aims

The optimal procedure for the treatment of ossification of the posterior longitudinal ligament (OPLL) remains controversial. The aim of this study was to compare the outcome of anterior cervical ossified posterior longitudinal ligament en bloc resection (ACOE) with posterior laminectomy and fusion with bone graft and internal fixation (PTLF) for the surgical management of patients with this condition.

Methods

Between July 2017 and July 2019, 40 patients with cervical OPLL were equally randomized to undergo surgery with an ACOE or a PTLF. The clinical and radiological results were compared between the two groups.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims

Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA).

Methods

A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 843 - 849
1 Aug 2023
Grandhi TSP Fontalis A Raj RD Kim WJ Giebaly DE Haddad FS

Telehealth has the potential to change the way we approach patient care. From virtual consenting to reducing carbon emissions, costs, and waiting times, it is a powerful tool in our clinical armamentarium. There is mounting evidence that remote diagnostic evaluation and decision-making have reached an acceptable level of accuracy and can safely be adopted in orthopaedic surgery. Furthermore, patients’ and surgeons’ satisfaction with virtual appointments are comparable to in-person consultations. Challenges to the widespread use of telehealth should, however, be acknowledged and include the cost of installation, training, maintenance, and accessibility. It is also vital that clinicians are conscious of the medicolegal and ethical considerations surrounding the medium and adhere strictly to the relevant data protection legislation and storage framework. It remains to be seen how organizations harness the full spectrum of the technology to facilitate effective patient care.

Cite this article: Bone Joint J 2023;105-B(8):843–849.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 764 - 774
1 Aug 2024
Rivera RJ Karasavvidis T Pagan C Haffner R Ast MP Vigdorchik JM Debbi EM

Aims

Conventional patient-reported surveys, used for patients undergoing total hip arthroplasty (THA), are limited by subjectivity and recall bias. Objective functional evaluation, such as gait analysis, to delineate a patient’s functional capacity and customize surgical interventions, may address these shortcomings. This systematic review endeavours to investigate the application of objective functional assessments in appraising individuals undergoing THA.

Methods

The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were applied. Eligible studies of THA patients that conducted at least one type of objective functional assessment both pre- and postoperatively were identified through Embase, Medline/PubMed, and Cochrane Central database-searching from inception to 15 September 2023. The assessments included were subgrouped for analysis: gait analysis, motion analysis, wearables, and strength tests.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 501 - 507
1 May 2024
Galloway AM Keene DJ Anderson A Holton C Redmond AC Siddle HJ Richards S Perry DC

Aims

The aim of this study was to produce clinical consensus recommendations about the non-surgical treatment of children with Perthes’ disease. The recommendations are intended to support clinical practice in a condition for which there is no robust evidence to guide optimal care.

Methods

A two-round, modified Delphi study was conducted online. An advisory group of children’s orthopaedic specialists consisting of physiotherapists, surgeons, and clinical nurse specialists designed a survey. In the first round, participants also had the opportunity to suggest new statements. The survey included statements related to ‘Exercises’, ‘Physical activity’, ‘Education/information sharing’, ‘Input from other services’, and ‘Monitoring assessments’. The survey was shared with clinicians who regularly treat children with Perthes’ disease in the UK using clinically relevant specialist groups and social media. A predetermined threshold of ≥ 75% for consensus was used for recommendation, with a threshold of between 70% and 75% being considered as ‘points to consider’.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1078 - 1085
1 Oct 2023
Cance N Batailler C Shatrov J Canetti R Servien E Lustig S

Aims

Tibial tubercle osteotomy (TTO) facilitates surgical exposure and protects the extensor mechanism during revision total knee arthroplasty (rTKA). The purpose of this study was to determine the rates of bony union, complications, and reoperations following TTO during rTKA, to assess the functional outcomes of rTKA with TTO at two years’ minimum follow-up, and to identify the risk factors of failure.

Methods

Between January 2010 and September 2020, 695 rTKAs were performed and data were entered into a prospective database. Inclusion criteria were rTKAs with concomitant TTO, without extensor mechanism allograft, and a minimum of two years’ follow-up. A total of 135 rTKAs were included, with a mean age of 65 years (SD 9.0) and a mean BMI of 29.8 kg/m2 (SD 5.7). The most frequent indications for revision were infection (50%; 68/135), aseptic loosening (25%; 34/135), and stiffness (13%; 18/135). Patients had standardized follow-up at six weeks, three months, six months, and annually thereafter. Complications and revisions were evaluated at the last follow-up. Functional outcomes were assessed using the Knee Society Score (KSS) and range of motion.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 622 - 634
1 Jun 2023
Simpson CJRW Wright E Ng N Yap NJ Ndou S Scott CEH Clement ND

Aims

This systematic review and meta-analysis aimed to compare the influence of patellar resurfacing following cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (TKA) on the incidence of anterior knee pain, knee-specific patient-reported outcome measures, complication rates, and reoperation rates.

Methods

A systematic review of MEDLINE, PubMed, and Google Scholar was performed to identify randomized controlled trials (RCTs) according to search criteria. Search terms used included: arthroplasty, replacement, knee (Mesh), TKA, prosthesis, patella, patellar resurfacing, and patellar retaining. RCTs that compared patellar resurfacing versus unresurfaced in primary TKA were included for further analysis. Studies were evaluated using the Scottish Intercollegiate Guidelines Network assessment tool for quality and minimization of bias. Data were synthesized and meta-analysis performed.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1301 - 1305
1 Nov 2024
Prajapati A Thakur RPS Gulia A Puri A

Aims

Reconstruction after osteoarticular resection of the proximal ulna for tumours is technically difficult and little has been written about the options that are available. We report a series of four patients who underwent radial neck to humeral trochlea transposition arthroplasty following proximal ulnar osteoarticular resection.

Methods

Between July 2020 and July 2022, four patients with primary bone tumours of the ulna underwent radial neck to humeral trochlea transposition arthroplasty. Their mean age was 28 years (12 to 41). The functional outcome was assessed using the range of motion (ROM) of the elbow, rotation of the forearm and stability of the elbow, the Musculoskeletal Tumor Society score (MSTS), and the nine-item abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH-9) score.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 324 - 335
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS

Aims

Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA.

Methods

This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 40 - 46
1 May 2024
Massè A Giachino M Audisio A Donis A Giai Via R Secco DC Limone B Turchetto L Aprato A

Aims

Ganz’s studies made it possible to address joint deformities on both the femoral and acetabular side brought about by Perthes’ disease. Femoral head reduction osteotomy (FHRO) was developed to improve joint congruency, along with periacetabular osteotomy (PAO), which may enhance coverage and containment. The purpose of this study is to show the clinical and morphological outcomes of the technique and the use of an implemented planning approach.

Methods

From September 2015 to December 2021, 13 FHROs were performed on 11 patients for Perthes’ disease in two centres. Of these, 11 hips had an associated PAO. A specific CT- and MRI-based protocol for virtual simulation of the corrections was developed. Outcomes were assessed with radiological parameters (sphericity index, extrusion index, integrity of the Shenton’s line, lateral centre-edge angle (LCEA), Tönnis angle), and clinical parameters (range of motion, visual analogue scale (VAS) for pain, Merle d'Aubigné-Postel score, modified Harris Hip Score (mHHS), and EuroQol five-dimension five-level health questionnaire (EQ-5D-5L)). Early and late complications were reported.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1314 - 1320
1 Dec 2023
Broida SE Sullivan MH Barlow JD Morrey M Scorianz M Wagner ER Sanchez-Sotelo J Rose PS Houdek MT

Aims

The scapula is a rare site for a primary bone tumour. Only a small number of series have studied patient outcomes after treatment. Previous studies have shown a high rate of recurrence, with functional outcomes determined by the preservation of the glenohumeral joint and deltoid. The purpose of the current study was to report the outcome of patients who had undergone tumour resection that included the scapula.

Methods

We reviewed 61 patients (37 male, 24 female; mean age 42 years (SD 19)) who had undergone resection of the scapula. The most common resection was type 2 (n = 34) according to the Tikhoff-Linberg classification, or type S1A (n = 35) on the Enneking classification.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 916 - 923
1 Sep 2024
Fricka KB Wilson EJ Strait AV Ho H Hopper, Jr RH Hamilton WG Sershon RA

Aims

The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution.

Methods

Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6).


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1104 - 1109
1 Oct 2022
Hansjee S Giebaly DE Shaarani SR Haddad FS

We aim to explore the potential technologies for monitoring and assessment of patients undergoing arthroplasty by examining selected literature focusing on the technology currently available and reflecting on possible future development and application. The reviewed literature indicates a large variety of different hardware and software, widely available and used in a limited manner, to assess patients’ performance. There are extensive opportunities to enhance and integrate the systems which are already in existence to develop patient-specific pathways for rehabilitation.

Cite this article: Bone Joint J 2022;104-B(10):1104–1109.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1259 - 1264
1 Dec 2023
Hurley ET Hughes AJ Savage-Elliott I Dejour D Campbell KA Mulcahey MK Wittstein JR Jazrawi LM

Aims

The aim of this study was to establish consensus statements on the diagnosis, nonoperative management, and indications, if any, for medial patellofemoral complex (MPFC) repair in patients with patellar instability, using the modified Delphi approach.

Methods

A total of 60 surgeons from 11 countries were invited to develop consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest within patellar instability. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered to be unanimous.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1306 - 1311
1 Nov 2024
Watts AC McDaid C Hewitt C

Aims

A review of the literature on elbow replacement found no consistency in the clinical outcome measures which are used to assess the effectiveness of interventions. The aim of this study was to define core outcome domains for elbow replacement.

Methods

A real-time Delphi survey was conducted over four weeks using outcomes from a scoping review of 362 studies on elbow replacement published between January 1990 and February 2021. A total of 583 outcome descriptors were rationalized to 139 unique outcomes. The survey consisted of 139 outcomes divided into 18 domains. The readability and clarity of the survey was determined by an advisory group including a patient representative. Participants were able to view aggregated responses from other participants in real time and to revisit their responses as many times as they wished during the study period. Participants were able to propose additional items for inclusion. A Patient and Public Inclusion and Engagement (PPIE) panel considered the consensus findings.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1265 - 1270
1 Dec 2023
Hurley ET Sherman SL Chahla J Gursoy S Alaia MJ Tanaka MJ Pace JL Jazrawi LM

Aims

The aim of this study was to establish consensus statements on medial patellofemoral ligament (MPFL) reconstruction, anteromedialization tibial tubercle osteotomy, trochleoplasty, and rehabilitation and return to sporting activity in patients with patellar instability, using the modified Delphi process.

Methods

This was the second part of a study dealing with these aspects of management in these patients. As in part I, a total of 60 surgeons from 11 countries contributed to the development of consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered unanimous.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 905 - 911
1 Aug 2023
Giannicola G Amura A Sessa P Prigent S Cinotti G

Aims

The aim of this study was to analyze how proximal radial neck resorption (PRNR) starts and progresses radiologically in two types of press-fit radial head arthroplasties (RHAs), and to investigate its clinical relevance.

Methods

A total of 97 patients with RHA were analyzed: 56 received a bipolar RHA (Group 1) while 41 received an anatomical implant (Group 2). Radiographs were performed postoperatively and after three, six, nine, and 12 weeks, six, nine, 12, 18, and 24 months, and annually thereafter. PRNR was measured in all radiographs in the four radial neck quadrants. The Mayo Elbow Performance Score (MEPS), the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH), and the patient-assessed American Shoulder and Elbow Surgeons score - Elbow (pASES-E) were used for the clinical assessment. Radiological signs of implant loosening were investigated.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1044 - 1049
1 Oct 2024
Abelleyra Lastoria DA Ogbolu C Olatigbe O Beni R Iftikhar A Hing CB

Aims

To determine whether obesity and malnutrition have a synergistic effect on outcomes from skeletal trauma or elective orthopaedic surgery.

Methods

Electronic databases including MEDLINE, Global Health, Embase, Web of Science, ScienceDirect, and PEDRo were searched up to 14 April 2024, as well as conference proceedings and the reference lists of included studies. Studies were appraised using tools according to study design, including the Oxford Levels of Evidence, the Institute of Health Economics case series quality appraisal checklist, and the CLARITY checklist for cohort studies. Studies were eligible if they reported the effects of combined malnutrition and obesity on outcomes from skeletal trauma or elective orthopaedic surgery.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 301 - 306
1 Mar 2023
Jennison T Ukoumunne O Lamb S Sharpe I Goldberg AJ

Aims

Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK.

Methods

A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 970 - 977
1 Sep 2024
De Rus Aznar I Ávila Lafuente JL Hachem A Díaz Heredia J Kany J Elhassan B Ruiz Ibán MÁ

Rotator cuff pathology is the main cause of shoulder pain and dysfunction in older adults. When a rotator cuff tear involves the subscapularis tendon, the symptoms are usually more severe and the prognosis after surgery must be guarded. Isolated subscapularis tears represent 18% of all rotator cuff tears and arthroscopic repair is a good alternative primary treatment. However, when the tendon is deemed irreparable, tendon transfers are the only option for younger or high-functioning patients. The aim of this review is to describe the indications, biomechanical principles, and outcomes which have been reported for tendon transfers, which are available for the treatment of irreparable subscapularis tears.

The best tendon to be transferred remains controversial. Pectoralis major transfer was described more than 30 years ago to treat patients with failed surgery for instability of the shoulder. It has subsequently been used extensively to manage irreparable subscapularis tendon tears in many clinical settings. Although pectoralis major reproduces the position and orientation of the subscapularis in the coronal plane, its position in the axial plane – anterior to the rib cage – is clearly different and does not allow it to function as an ideal transfer. Consistent relief of pain and moderate recovery of strength and function have been reported following the use of this transfer. In an attempt to improve on these results, latissimus dorsi tendon transfer was proposed as an alternative and the technique has evolved from an open to an arthroscopic procedure. Satisfactory relief of pain and improvements in functional shoulder scores have recently been reported following its use. Both pectoralis minor and upper trapezius transfers have also been used in these patients, but the outcomes that have been reported do not support their widespread use.

Cite this article: Bone Joint J 2024;106-B(9):970–977.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 949 - 956
1 Sep 2024
Matthews PA Scammell BE Coughlin TA Nightingale J Ollivere BJ

Aims

This study aimed to compare the outcomes of two different postoperative management approaches following surgical fixation of ankle fractures: traditional cast immobilization versus the Early Motion and Directed Exercise (EMADE) programme.

Methods

A total of 157 patients aged 18 years or older who underwent successful open reduction and internal fixation (ORIF) of Weber B (AO44B) ankle fractures were recruited to this randomized controlled trial. At two weeks post-surgical fixation, participants were randomized to either light-weight cast-immobilization or the EMADE programme, consisting of progressive home exercises and weekly advice and education. Both groups were restricted to non-weightbearing until six weeks post-surgery. The primary outcome was assessed using the Olerud-Molander Ankle Score (OMAS) questionnaire at 12 weeks post-surgery, with secondary measures at two, six, 24, and 52 weeks. Exploratory cost-effectiveness analyses were also performed.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 17 - 23
1 Mar 2024
LaValva SM LeBrun DG Canoles HG Ren R Padgett DE Su EP

Aims

Professional dancers represent a unique patient population in the setting of hip arthroplasty, given the high degree of hip strength and mobility required by their profession. We sought to determine the clinical outcomes and ability to return to professional dance after total hip arthroplasty (THA) or hip resurfacing arthroplasty (HRA).

Methods

Active professional dancers who underwent primary THA or HRA at a single institution with minimum one-year follow-up were included in the study. Primary outcomes included the rate of return to professional dance, three patient-reported outcome measures (PROMs) (modified Harris Hip Score (mHHS), Hip disability and Osteoarthritis Outcome Score for Joint Replacement (HOOS-JR), and Lower Extremity Activity Scale (LEAS)), and postoperative complications.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 696 - 704
1 Jul 2024
Barvelink B Reijman M Smidt S Miranda Afonso P Verhaar JAN Colaris JW

Aims

It is not clear which type of casting provides the best initial treatment in adults with a distal radial fracture. Given that between 32% and 64% of adequately reduced fractures redisplace during immobilization in a cast, preventing redisplacement and a disabling malunion or secondary surgery is an aim of treatment. In this study, we investigated whether circumferential casting leads to fewer fracture redisplacements and better one-year outcomes compared to plaster splinting.

Methods

In a pragmatic, open-label, multicentre, two-period cluster-randomized superiority trial, we compared these two types of casting. Recruitment took place in ten hospitals. Eligible patients aged ≥ 18 years with a displaced distal radial fracture, which was acceptably aligned after closed reduction, were included. The primary outcome measure was the rate of redisplacement within five weeks of immobilization. Secondary outcomes were the rate of complaints relating to the cast, clinical outcomes at three months, patient-reported outcome measures (PROMs) (using the numerical rating scale (NRS), the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores), and adverse events such as the development of compartment syndrome during one year of follow-up. We used multivariable mixed-effects logistic regression for the analysis of the primary outcome measure.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 148 - 157
1 Feb 2023
Koster LA Rassir R Kaptein BL Sierevelt IN Schager M Nelissen RGHH Nolte PA

Aims

The primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS) total knee arthroplasty (TKA) designs, two years postoperatively, using radiostereometric analysis (RSA) in order to assess the risk of the development of aseptic loosening. A secondary aim was to compare clinical and patient-reported outcome measures (PROMs) between the designs.

Methods

A total of 61 TKAs were analyzed in this randomized clinical RSA trial. RSA examinations were performed one day and three, six, 12, and 24 months postoperatively. The maximal total point motion (MPTM), translations, and rotations of the components were analyzed. PROMs and clinical data were collected preoperatively and at six weeks and three, six, 12, and 24 months postoperatively. Linear mixed effect modelling was used for statistical analyses.


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims

Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice.

Methods

This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m2 (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 534 - 542
1 May 2023
Makaram NS Khan LAK Jenkins PJ Robinson CM

Aims

The outcomes following nonoperative management of minimally displaced greater tuberosity (GT) fractures, and the factors which influence patient experience, remain poorly defined. We assessed the early patient-derived outcomes following these injuries and examined the effect of a range of demographic- and injury-related variables on these outcomes.

Methods

In total, 101 patients (53 female, 48 male) with a mean age of 50.9 years (19 to 76) with minimally displaced GT fractures were recruited to a prospective observational cohort study. During the first year after injury, patients underwent experiential assessment using the Disabilities of the Arm, Shoulder and Hand (DASH) score and assessment of associated injuries using MRI performed within two weeks of injury. The primary outcome was the one-year DASH score. Multivariate analysis was used to assess the effect of patient demographic factors, complications, and associated injuries, on outcome.


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 953 - 962
1 Aug 2022
Johnson NA Fairhurst C Brealey SD Cook E Stirling E Costa M Divall P Hodgson S Rangan A Dias JJ

Aims

There has been an increasing use of early operative fixation for scaphoid fractures, despite uncertain evidence. We conducted a meta-analysis to evaluate up-to-date evidence from randomized controlled trials (RCTs), comparing the effectiveness of the operative and nonoperative treatment of undisplaced and minimally displaced (≤ 2 mm displacement) scaphoid fractures.

Methods

A systematic review of seven databases was performed from the dates of their inception until the end of March 2021 to identify eligible RCTs. Reference lists of the included studies were screened. No language restrictions were applied. The primary outcome was the patient-reported outcome measure of wrist function at 12 months after injury. A meta-analysis was performed for function, pain, range of motion, grip strength, and union. Complications were reported narratively.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 24 - 30
1 Jun 2020
Livermore AT Erickson JA Blackburn B Peters CL

Aims. A significant percentage of patients remain dissatisfied after total knee arthroplasty (TKA). The aim of this study was to determine whether the sequential addition of accelerometer-based navigation for femoral component preparation and sensor-guided ligament balancing improved complication rates, radiological alignment, or patient-reported outcomes (PROMs) compared with a historical control group using conventional instrumentation. Methods. This retrospective cohort study included 371 TKAs performed by a single surgeon sequentially. A historical control group, with the use of intramedullary guides for distal femoral resection and surgeon-guided ligament balancing, was compared with a group using accelerometer-based navigation for distal femoral resection and surgeon-guided balancing (group 1), and one using navigated femoral resection and sensor-guided balancing (group 2). Primary outcome measures were Patient-Reported Outcomes Measurement Information System (PROMIS) and Knee injury and Osteoarthritis Outcome (KOOS) scores measured preoperatively and at six weeks and 12 months postoperatively. The position of the components and the mechanical axis of the limb were measured postoperatively. The postoperative range of motion (ROM), haematocrit change, and complications were also recorded. Results. There were 194 patients in the control group, 103 in group 1, and 74 in group 2. There were no significant differences in baseline demographics between the groups. Patients in group 2 had significantly higher baseline mental health subscores than control and group 1 patients (53.2 vs 50.2 vs 50.2, p = 0.041). There were no significant differences in any PROMs at six weeks or 12 months postoperatively (p > 0.05). There was no difference in the rate of manipulation under anaesthesia (MUA), complication rates, postoperative ROM, or blood loss. There were fewer mechanical axis outliers in groups 1 and 2 (25.2%, 14.9% respectively) versus control (28.4%), but this was not statistically significant (p = 0.10). Conclusion. The sequential addition of navigation of the distal femoral cut and sensor-guided ligament balancing did not improve short-term PROMs, radiological outcomes, or complication rates compared with conventional techniques. The costs of these added technologies may not be justified. Cite this article: Bone Joint J 2020;102-B(6 Supple A):24–30


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 818 - 823
1 Jun 2017
Kodama A Mizuseki T Adachi N

Aims. We assessed the long-term (more than ten-year) outcomes of the Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis (RA). Materials and Methods. We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n = 20) in 31 patients with RA who had undergone a Kudo type-5 total elbow arthroplasty (TEA) between 1994 and 2003, and had been followed up for more than ten years. The humeral component was cementless and the all-polyethylene ulnar component cemented in every patient. Clinical outcome was assessed using the Mayo elbow performance score. We calculated the revision rate and evaluated potential risk factors for revision. The duration of follow-up was a mean 141 months (120 to 203). Results. Aseptic loosening of the ulnar component occurred in 11 elbows. There was no radiolucency around any humeral component. There was one deep infection. The survival rate according to Kaplan-Meier survivorship analysis was 87.8% after five years and 70.7% after ten years. The range of extension/flexion was a mean -38° (-80° to 0°)/105° (30° to 150°) before surgery and -40° (-70° to -20°)/132° (100° to 150°) at the final follow-up, while the mean Mayo elbow performance score was 43 before surgery and 80 at final follow-up. Disease duration of RA up to the TEA of < 15 years and a pre-operative range of movement (ROM) of > 85° were significant risk factors for revision or aseptic loosening. Conclusion. Although Kudo type-5 prostheses gave satisfactory results in the short-term, aseptic loosening increased after five years. In most cases, elbow function was maintained in the long-term without loosening of the implant. A short duration from the onset of RA to TEA and a large pre-operative ROM were significant risk factors for revision or aseptic loosening. Cite this article: Bone Joint J 2017;99-B:818–23


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 59 - 65
1 Jan 2019
Katchky AM Jones CW Walter WL Shimmin AJ

Aims. Between 15% and 20% of patients remain dissatisfied following total knee arthroplasty (TKA). The SAIPH knee system (MatOrtho, Surrey, United Kingdom) is a medial ball and socket TKA that has been designed to replicate native knee kinematics in order to maximize the range of movement, stability, and function. This system is being progressively introduced in a stepwise fashion, with this study reporting the mid-term clinical and radiological outcomes. Patients and Methods. A retrospective review was undertaken of the first 100 consecutive patients with five-year follow-up following SAIPH TKA performed by the senior authors. The data that were collected included the demographics of the patients, clinical findings, the rate of intraoperative ligamentous release, patient-reported outcome measures (PROMS), radiological assessment, complications, and all-cause revision. Revision data were cross-checked with a national registry. Results. A total of 100 TKAs in 92 patients were included. Three patients died (three TKAs) and a further two TKAs were revised. Of the remaining 95 TKAs, five-year follow-up data were available for 81 TKAs (85%) in 87 patients. There were significant improvements in all PROMs and high satisfaction. The mean ROM at final follow-up was from 0° (full extension) to 124° flexion. There were seven major complications (7%): one infection, two deep vein thromboses, one cerebrovascular event, and two patients with stiffness requiring a manipulation under anaesthesia. Two patients required a lateral retinacular release to optimize patellar tracking in valgus knees; no additional ligament releases were performed in any patient. Radiological analysis demonstrated no evidence of implant-related complications. Conclusion. These results demonstrate satisfactory clinical and radiological outcomes at five years following a medial ball and socket TKA. The complication and revision rates are consistent with those previously reported for patients undergoing TKA. These results demonstrate the safety and efficacy of the SAIPH Knee TKA system and support its wider use


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 474 - 480
1 May 2023
Inclan PM Brophy RH

Anterior cruciate ligament (ACL) graft failure from rupture, attenuation, or malposition may cause recurrent subjective instability and objective laxity, and occurs in 3% to 22% of ACL reconstruction (ACLr) procedures. Revision ACLr is often indicated to restore knee stability, improve knee function, and facilitate return to cutting and pivoting activities. Prior to reconstruction, a thorough clinical and diagnostic evaluation is required to identify factors that may have predisposed an individual to recurrent ACL injury, appreciate concurrent intra-articular pathology, and select the optimal graft for revision reconstruction. Single-stage revision can be successful, although a staged approach may be used when optimal tunnel placement is not possible due to the position and/or widening of previous tunnels. Revision ACLr often involves concomitant procedures such as meniscal/chondral treatment, lateral extra-articular augmentation, and/or osteotomy. Although revision ACLr reliably restores knee stability and function, clinical outcomes and reoperation rates are worse than for primary ACLr.

Cite this article: Bone Joint J 2023;105-B(5):474–480.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1158 - 1164
1 Oct 2024
Jakobi T Krieg I Gramlich Y Sauter M Schnetz M Hoffmann R Klug A

Aims

The aim of this study was to evaluate the outcome of complex radial head fractures at mid-term follow-up, and determine whether open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA) should be recommended for surgical treatment.

Methods

Patients who underwent surgery for complex radial head fractures (Mason type III, ≥ three fragments) were divided into two groups (ORIF and RHA) and propensity score matching was used to individually match patients based on patient characteristics. Ultimately, 84 patients were included in this study. After a mean follow-up of 4.1 years (2.0 to 9.5), patients were invited for clinical and radiological assessment. The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score were evaluated.


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 747 - 757
1 Jun 2022
Liang H Yang Y Guo W Yan L Tang X Li D Qu H Zang J Du Z

Aims

The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection.

Methods

From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.