Advertisement for orthosearch.org.uk
Results 1 - 100 of 307
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1577 - 1581
1 Nov 2015
Balci HI Kocaoglu M Sen C Eralp L Batibay SG Bilsel K

A retrospective study was performed in 18 patients with achondroplasia, who underwent bilateral humeral lengthening between 2001 and 2013, using monorail external fixators. The mean age was ten years (six to 15) and the mean follow-up was 40 months (12 to 104). . The mean disabilities of the arm, shoulder and hand (DASH) score fell from 32.3 (20 to 40) pre-operatively to 9.4 (6 to 14) post-operatively (p = 0.037). A mean lengthening of 60% (40% to 95%) was required to reach the goal of independent perineal hygiene. One patient developed early consolidation, and fractures occurred in the regenerate bone of four humeri in three patients. There were three transient radial nerve palsies. Humeral lengthening increases the independence of people with achondroplasia and is not just a cosmetic procedure. Cite this article: Bone Joint J 2015;97-B:1577–81


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1642 - 1646
1 Dec 2006
Shalaby S Shalaby H Bassiony A

We report the results of limb salvage for non-metastatic osteosarcoma of the distal tibia using resection arthrodesis, autogenous fibular graft and fixation by an Ilizarov external fixator. In six patients with primary osteosarcoma of the distal tibia who refused amputation, treatment with wide en bloc resection and tibiotalar arthrodesis was undertaken. The defect was reconstructed using non-vascularised free autogenous fibular strut graft in three patients and a vascularised pedicular fibular graft in three, all supplemented with iliac cancellous graft at the graft-host junction. An Ilizarov external fixator was used for stabilisation of the reconstruction. In five patients sound fusion occurred at a mean of 13.2 months (8 to 20) with no evidence of local recurrence or deep infection at final follow-up. The mean post-operative functional score was 70% (63% to 73%) according to the Musculoskeletal Tumour Society scoring system. All five patients showed graft hypertrophy. Union of the graft was faster in cases reconstructed by vascularised fibular grafts. One patient who had a poor response to pre-operative chemotherapy developed local tumour recurrence at one year post-operatively and required subsequent amputation


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 955 - 962
1 Nov 1999
Lindahl J Hirvensalo E Böstman O Santavirta S

We reviewed 110 patients with an unstable fracture of the pelvic ring who had been treated with a trapezoidal external fixator after a mean follow-up of 4.1 years. There were eight open-book (type B1, B3-1) injuries, 62 lateral compression (type B2, B3-2) and 40 rotationally and vertically unstable (type C1-C3) injuries. The rate of complications was high with loss of reduction in 57%, malunion in 58%, nonunion in 5%, infection at the pin site in 24%, loosening of the pins in 2%, injury to the lateral femoral cutaneous nerve in 2%, and pressure sores in 3%. The external fixator failed to give and maintain a proper reduction in six of the eight open-book injuries, in 20 of the 62 lateral compression injuries, and in 38 of the 40 type-C injuries. Poor functional results were usually associated with failure of reduction and an unsatisfactory radiological appearance. In type-C injuries more than 10 mm of residual vertical displacement of the injury to the posterior pelvic ring was significantly related to poor outcome. In 14 patients in this unsatisfactory group poor functional results were also affected by associated nerve injuries. In lateral compression injuries the degree of displacement of fractures of the pubic rami caused by internal rotation of the hemipelvis was an important prognostic factor. External fixation may be useful in the acute phase of resuscitation but it is of limited value in the definitive treatment of an unstable type-C injury and in type-B open-book injuries. It is usually unnecessary in minimally displaced lateral compression injuries


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 23 - 29
1 Jan 2002
Vossinakis IC Badras LS

In a prospective, randomised study we have compared the pertrochanteric external fixator (PF) with the sliding hip screw (SHS) in 100 consecutive patients who were allocated randomly to the two methods of treatment. Details of the patients and the patterns of fracture were similar in both groups. Follow-up was for six months. Use of the PF was associated with significantly less blood loss, a shorter operating time, reduced postoperative pain, shorter hospitalisation (p < 0.001), earlier mobilisation (p < 0.001) and a reduced rate of mechanical complications (p < 0.01). Superficial infection was significantly more common with the PF (p < 0.01), but without long-term adverse consequences. There were no differences in the healing of the fracture, mortality or final functional outcome. Our results indicate that the external fixator is an effective and safe device for treating pertrochanteric fractures and should be considered as a useful alternative to conventional fixation with the sliding hip screw


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 601 - 607
1 May 2016
McClelland D Barlow D Moores TS Wynn-Jones C Griffiths D Ogrodnik PJ Thomas PBM

In arthritis of the varus knee, a high tibial osteotomy (HTO) redistributes load from the diseased medial compartment to the unaffected lateral compartment. We report the outcome of 36 patients (33 men and three women) with 42 varus, arthritic knees who underwent HTO and dynamic correction using a Garches external fixator until they felt that normal alignment had been restored. The mean age of the patients was 54.11 years (34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3 to 10) post-operatively. Radiographs, gait analysis and visual analogue scores for pain were measured pre- and post-operatively, at one year and at medium-term follow-up (mean six years; 2 to 10). Failure was defined as conversion to knee arthroplasty. . Pre-operative gait analysis divided the 42 knees into two equal groups with high (17 patients) or low (19 patients) adductor moments. After correction, a statistically significant (p < 0.001, t-test,) change in adductor moment was achieved and maintained in both groups, with a rate of failure of three knees (7.1%), and 89% (95% confidence interval (CI) 84.9 to 94.7) survivorship at medium-term follow-up. At final follow-up, after a mean of 15.9 years (12 to 20), there was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of adductor moment group, with a mean time to conversion to knee arthroplasty of 9.5 years (3 to 18; 95% confidence interval ± 2.5). . HTO remains a useful option in the medium-term for the treatment of medial compartment osteoarthritis of the knee but does not last in the long-term. . Cite this article: Bone Joint J 2016;98-B:601–7


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 734 - 736
1 Nov 1987
Vegter J

The management of carpal dislocation after a late diagnosis is difficult. Open reduction is the usual treatment but collapse of the carpus may be hard to overcome without extensive dissection and consequent damage to the blood supply, ligaments and articular cartilage. A technique of distraction by an external fixator followed by semi-closed reduction is described and its successful use is reported in two cases


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1031 - 1036
1 Nov 1998
McKee MD Bowden SH King GJ Patterson SD Jupiter JB Bamberger HB Paksima N

We have treated 16 patients with recurrent complex elbow instability using a hinged external fixator. All patients had instability, dislocation or subluxation of the ulnohumeral joint. The injuries were open in eight patients and were associated with 20 other fractures and five peripheral nerve injuries. Two patients had received initial treatment from us; 14 had previously had a mean of 2.1 unsuccessful surgical procedures (1 to 6). The fixator was applied at a mean of 4.8 weeks (0 to 9) after the injury and remained on the elbow for a mean of 8.5 weeks (6 to 11). After treatment we found the mean range of flexion-extension to be 105° (65 to 140). At a final follow-up of 23 months (14 to 40), the mean Morrey score was 84 (49 to 96): this translated into one poor, three fair, ten good and two excellent results. Complications included one fractured humeral pin, one temporary palsy of the radial nerve, one recurrent instability, one wound infection, one severe pin-track infection and one patient with reflex sympathetic dystrophy. Although technically demanding, the use of the fixator is an important advance in the management of recurrent complex elbow instability after failure of conventional treatment


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1296 - 1300
1 Sep 2015
Jauregui JJ Bor N Thakral R Standard SC Paley D Herzenberg JE

External fixation is widely used in orthopaedic and trauma surgery. Infections around pin or wire sites, which are usually localised, non-invasive, and are easily managed, are common. Occasionally, more serious invasive complications such as necrotising fasciitis (NF) and toxic shock syndrome (TSS) may occur.

We retrospectively reviewed all patients who underwent external fixation between 1997 and 2012 in our limb lengthening and reconstruction programme. A total of eight patients (seven female and one male) with a mean age of 20 years (5 to 45) in which pin/wire track infections became limb- or life-threatening were identified. Of these, four were due to TSS and four to NF. Their management is described. A satisfactory outcome was obtained with early diagnosis and aggressive medical and surgical treatment.

Clinicians caring for patients who have external fixation and in whom infection has developed should be aware of the possibility of these more serious complications. Early diagnosis and aggressive treatment are required in order to obtain a satisfactory outcome.

Cite this article: Bone Joint J 2015;97-B:1296–1300.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1417 - 1422
1 Oct 2015
Ferreira N Marais LC Aldous C

Tibial nonunion represents a spectrum of conditions which are challenging to treat, and optimal management remains unclear despite its high rate of incidence. We present 44 consecutive patients with 46 stiff tibial nonunions, treated with hexapod external fixators and distraction to achieve union and gradual deformity correction. There were 31 men and 13 women with a mean age of 35 years (18 to 68) and a mean follow-up of 12 months (6 to 40). No tibial osteotomies or bone graft procedures were performed. Bony union was achieved after the initial surgery in 41 (89.1%) tibias. Four persistent nonunions united after repeat treatment with closed hexapod distraction, resulting in bony union in 45 (97.8%) patients. The mean time to union was 23 weeks (11 to 49). Leg-length was restored to within 1 cm of the contralateral side in all tibias. Mechanical alignment was restored to within 5° of normal in 42 (91.3%) tibias. Closed distraction of stiff tibial nonunions can predictably lead to union without further surgery or bone graft. In addition to generating the required distraction to achieve union, hexapod circular external fixators can accurately correct concurrent deformities and limb-length discrepancies.

Cite this article: Bone Joint J 2015;97-B:1417–22.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1020 - 1023
1 Nov 1998
Halliwell PJ

External fixation is useful for the treatment of selected injuries to the hand. Some authors have suggested that external fixation of a phalanx may tether the extensor hood, thereby hindering active movements and predisposing to permanent adhesions. There is no consensus as to the best site for placement of the pin to minimise these problems. This study was performed on cadaver specimens to investigate the influence of the pin site on the range of simulated active movement of the interphalangeal joint. The dorsal midline position produces least interference with the extensor mechanism; radial and ulnar to this, interdigitating oblique fibres prevent a clean longitudinal split in the direction of gliding thus limiting movement of the extensor hood. At the proximal phalanx, positioning of the pin just off the midline avoids the thickening of the proximal median hood, whereas at the middle phalanx, a true midline position utilises the bare area at its base.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 180 - 181
1 Jan 1991
Kocialkowski A Wallace W


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 157 - 158
1 Jan 1995
Johnson T McGanity P


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 92 - 97
1 Jan 2010
Kulkarni GS Kulkarni VS Shyam AK Kulkarni RM Kulkarni MG Nayak P

Arthrolysis and dynamic splinting have been used in the treatment of elbow contractures, but there is no standardised protocol for treatment of severe contractures with an arc of flexion < 30°. We present our results of radical arthrolysis with twin incisions with the use of a monolateral hinged fixator to treat very severe extra-articular contracture of the elbow. This retrospective study included 26 patients (15 males and 11 females) with a mean age of 30 years (12 to 60). The mean duration of stiffness was 9.1 months (5.4 to 18) with mean follow-up of 5.2 years (3.5 to 9.4). The mean pre-operative arc of movement was 15.6° (0° to 30°), with mean pre-operative flexion of 64.1° (30° to 120°) and mean pre-operative extension of 52.1° (10° to 90°). Post-operatively the mean arc improved to 102.4° (60° to 135°), the mean flexion improved to 119.1° (90° to 140°) and mean extension improved to 16.8° (0° to 30°) (p < 0.001). The Mayo elbow score improved from a mean of 45 (30 to 65) to 89 (75 to 100) points, and 13 had excellent, nine had good, three had fair and one had a poor result. We had one case of severe instability and one wound dehiscence which responded well to treatment. One case had deep infection with poor results which responded well to treatment.

Our findings indicate that this method is very effective in the treatment of severe elbow contracture; however, a randomised controlled study is necessary for further evaluation.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 690 - 691
1 Jul 1991
Fowler J Gie G Maceachern A


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 755 - 765
1 Jun 2020
Liebs TR Burgard M Kaiser N Slongo T Berger S Ryser B Ziebarth K

Aims. We aimed to evaluate the health-related quality of life (HRQoL) in children with supracondylar humeral fractures (SCHFs), who were treated following the recommendations of the Paediatric Comprehensive AO Classification, and to assess if HRQoL was associated with AO fracture classification, or fixation with a lateral external fixator compared with closed reduction and percutaneous pinning (CRPP). Methods. We were able to follow-up on 775 patients (395 girls, 380 boys) who sustained a SCHF from 2004 to 2017. Patients completed questionnaires including the Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH; primary outcome), and the Pediatric Quality of Life Inventory (PedsQL). Results. An AO type I SCHF was most frequent (327 children; type II: 143; type III: 150; type IV: 155 children). All children with type I fractures were treated nonoperatively. Two children with a type II fracture, 136 with a type III fracture, and 141 children with a type IV fracture underwent CRPP. In the remaining 27 children with type III or IV fractures, a lateral external fixator was necessary for closed reduction. There were no open reductions. After a mean follow-up of 6.3 years (SD 3.7), patients with a type I fracture had a mean QuickDASH of 2.0 (SD 5.2), at a scale of 0 to 100, with lower values representing better HRQoL (type II: 2.8 (SD 10.7); type III: 3.3 (SD 8.0); type IV: 1.8 (SD 4.6)). The mean function score of the PedsQL ranged from 97.4 (SD 8.0) for type I to 96.1 (SD 9.1) for type III fractures, at a scale of 0 to 100, with higher values representing better HRQoL. Conclusion. In this cohort of 775 patients in whom nonoperative treatment was chosen for AO type I and II fractures and CRPP or a lateral external fixator was used in AO type III and IV fractures, there was equally excellent mid- and long-term HRQoL when assessed by the QuickDASH and PedsQL. These results indicate that the treatment protocol followed in this study is unambiguous, avoids open reductions, and is associated with excellent treatment outcomes. Cite this article: Bone Joint J 2020;102-B(6):755–765


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 170 - 175
1 Jun 2020
Chalmers BP Matrka AK Sems SA Abdel MP Sierra RJ Hanssen AD Pagnano MW Mabry TM Perry KI

Aims. Arthrodesis is rarely used as a salvage procedure for patients with a chronically infected total knee arthroplasty (TKA), and little information is available about the outcome. The aim of this study was to assess the reliability, durability, and safety of this procedure as the definitive treatment for complex, chronically infected TKA, in a current series of patients. Methods. We retrospectively identified 41 patients (41 TKAs) with a complex infected TKA, who were treated between 2002 and 2016 using a deliberate, two-stage knee arthrodesis. Their mean age was 64 years (34 to 88) and their mean body mass index (BMI) was 39 kg/m. 2. (25 to 79). The mean follow-up was four years (2 to 9). The extensor mechanism (EM) was deficient in 27 patients (66%) and flap cover was required in 14 (34%). Most patients were host grade B (56%) or C (29%), and limb grade 3 (71%), according to the classification of McPherson et al. A total of 12 patients (29%) had polymicrobial infections and 20 (49%) had multi-drug resistant organisms; fixation involved an intramedullary nail in 25 (61%), an external fixator in ten (24%), and dual plates in six (15%). Results. Survivorship free from amputation, persistent infection, and reoperation, other than removal of an external fixator, at five years was 95% (95% confidence interval (CI) 89% to 100%), 85% (95% CI 75% to 95%), and 64% (95% CI 46% to 82%), respectively. Reoperation, other than removal of an external fixator, occurred in 13 patients (32%). After the initial treatment, radiological nonunion developed in ten knees (24%). Nonunion was significantly correlated with persistent infection (p = 0.006) and external fixation (p = 0.005). Of those patients who achieved limb salvage, 34 (87%) remained mobile and 31 (79%) had ‘absent’ or ‘minimal’ pain ratings. Conclusion. Knee arthrodesis using a two-stage protocol achieved a survivorship free from amputation for persistent infection of 95% at five years with 87% of patients were mobile at final follow-up. However, early reoperation was common (32%). This is not surprising as this series included worst-case infected TKAs in which two-thirds of the patients had a disrupted EM, one-third required flap cover, and most had polymicrobial or multi-drug resistant organisms. Cite this article: Bone Joint J 2020;102-B(6 Supple A):170–175


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 11 - 16
1 Jan 2023
San-Julián M Gómez-Álvarez J Idoate MÁ Aquerreta JD Vázquez-García B Lamo-Espinosa JM

Paediatric bone sarcomas are a dual challenge for orthopaedic surgeons in terms of tumour resection and reconstruction, as it is important to minimize functional and growth problems without compromising survival rates. Cañadell’s technique consists of a Type I epiphysiolysis performed using continuous distraction by an external fixator prior to resection. It was designed to achieve a safe margin due to the ability of the physeal cartilage to be a barrier to tumour spread in some situations, avoiding the need for articular reconstruction, and preserving the growth capacity most of the times. Despite initial doubts raised in the scientific community, this technique is now widely used in many countries for the treatment of metaphyseal paediatric bone sarcomas. This annotation highlights the importance of Cañadell’s work and reviews the experience of applying it to bone sarcoma patients over the last 40 years. Cite this article: Bone Joint J 2023;105-B(1):11–16


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims. As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach. Methods. A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30). Results. A median tibial distraction of 44 mm (IQR 31 to 49) was achieved with a mean distraction index of 0.5 mm/day (standard deviation 0.13) and median consolidation index of 41.2 days/cm (IQR 34 to 51). Accuracy, precision, and reliability were 91%, 92%, and 97%, respectively. New temporary range of motion limitations occurred in 51% of segments (34/67). Distraction-related equinus deformity treated by Achilles tendon lengthening was the most common major complication recorded in 16% of segments (11/67). In 95% of patients (55/58) the distraction goal was achieved with 42% unplanned additional interventions per segment (28/67). The median postoperative LD-SRS-30 score was 4.0 (IQR 3.6 to 4.3). Conclusion. Tibial distraction osteogenesis using motorized ILNs inserted via an antegrade approach appears to be a reliable and precise procedure. Temporary joint stiffness of the knee or ankle should be expected in up to every second patient. A high rate and wide range of complications of variable severity should be anticipated. Cite this article: Bone Joint J 2024;106-B(3):293–302


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1248 - 1255
1 Sep 2020
Laufer A Frommer A Gosheger G Roedl R Broeking JN Toporowski G Rachbauer AM Vogt B

Aims. The treatment of tibial aplasia is controversial. Amputation represents the gold standard with good functional results, but is frequently refused by the families. In these patients, treatment with reconstructive limb salvage can be considered. Due to the complexity of the deformity, this remains challenging and should be staged. The present study evaluated the role of femoro-pedal distraction using a circular external fixator in reconstructive treatment of tibial aplasia. The purpose of femoro-pedal distraction is to realign the limb and achieve soft tissue lengthening to allow subsequent reconstructive surgery. Methods. This was a retrospective study involving ten patients (12 limbs) with tibial aplasia, who underwent staged reconstruction. During the first operation a circular hexapod external fixator was applied and femoro-pedal distraction was undertaken over several months. Subsequent surgery included reconstruction of the knee joint and alignment of the foot. Results. The mean follow-up was 7.1 years (2 to 10). The mean age of the patients at the time of the application of the fixator was 2.3 years (1.1 to 5.0). The mean time under distraction was 139.7 days (81.0 to 177.0). A mean fibular distalization of 38.7 mm (14.0 to 67.0) was achieved. Pin infections occurred in four limbs (33.3%) and osteitis in one. A femoral fracture occurred in one patient. Premature removal of the frame was not required in any patient. Sufficient realignment of the leg as well as soft tissue lengthening was achieved in all patients, allowing subsequent reconstruction. All patients were able to mobilize fully weight bearing after reconstruction. Functional outcome was limited in all limbs, and five patients (50.0%) required additional reconstructive operations. Conclusion. Regarding the functional results in the treatment of tibial aplasia, amputation remains superior to limb salvage. The latter procedure should only be performed in patients whose parents refuse amputation. Femoro-pedal distraction efficiently prepares the limb by realigning the leg and soft tissue lengthening. Minor complications are frequent, but usually do not hinder the continuation of distraction. Even though a fully weight-bearing limb is achieved, the functional outcome of reconstructive treatment remains limited. Recurrent deformities frequently occur and may require further operations. Cite this article: Bone Joint J 2020;102-B(9):1248–1255


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 146 - 152
1 Jan 2010
Bilen FE Kocaoglu M Eralp L Balci HI

We report the results of using a combination of fixator-assisted nailing with lengthening over an intramedullary nail in patients with tibial deformity and shortening. Between 1997 and 2007, 13 tibiae in nine patients with a mean age of 25.4 years (17 to 34) were treated with a unilateral external fixator for acute correction of deformity, followed by lengthening over an intramedullary nail with a circular external fixator applied at the same operating session. At the end of the distraction period locking screws were inserted through the intramedullary nail and the external fixator was removed. The mean amount of lengthening was 5.9 cm (2 to 8). The mean time of external fixation was 90 days (38 to 265). The mean external fixation index was 15.8 days/cm (8.9 to 33.1) and the mean bone healing index was 38 days/cm (30 to 60). One patient developed an equinus deformity which responded to stretching and bracing. Another developed a drop foot due to a compartment syndrome, which was treated by fasciotomy. It recovered in three months. Two patients required bone grafting for poor callus formation. We conclude that the combination of fixator-assisted nailing with lengthening over an intramedullary nail can reduce the overall external fixation time and prevent fractures and deformity of the regenerated bone


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 958 - 965
1 Jul 2008
Leong JJH Leff DR Das A Aggarwal R Reilly P Atkinson HDE Emery RJ Darzi AW

The aim of this study was to validate the use of three models of fracture fixation in the assessment of technical skills. We recruited 21 subjects (six experts, seven intermediates, and eight novices) to perform three procedures: application of a dynamic compression plate on a cadaver porcine model, insertion of an unreamed tibial intramedullary nail, and application of a forearm external fixator, both on synthetic bone models. The primary outcome measures were the Objective Structural Assessment of technical skills global rating scale on video recordings of the procedures which were scored by two independent expert observers, and the hand movements of the surgeons which were analysed using the Imperial College Surgical Assessment Device. The video scores were significantly different for the three groups in all three procedures (p < 0.05), with excellent inter-rater reliability (α = 0.88). The novice and intermediate groups specifically were significantly different in their performance with dynamic compression plate and intramedullary nails (p < 0.05). Movement analysis distinguished between the three groups in the dynamic compression plate model, but a ceiling effect was demonstrated in the intramedullary nail and external fixator procedures, where intermediates and experts performed to comparable standards (p > 0.6). A total of 85% (18 of 21) of the subjects found the dynamic compression model and 57% (12 of 21) found all the models acceptable tools of assessment. This study has validated a low-cost, high-fidelity porcine dynamic compression plate model using video rating scores for skills assessment and movement analysis. It has also demonstrated that Synbone models for the application of and intramedullary nail and an external fixator are less sensitive and should be improved for further assessment of surgical skills in trauma. The availability of valid objective tools of assessment of surgical skills allows further studies into improving methods of training


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1667 - 1672
1 Dec 2013
Oh C Apivatthakakul T Oh J Kim J Lee H Kyung H Baek S Jung G

Although gradual bone transport may permit the restoration of large-diameter bones, complications are common owing to the long duration of external fixation. In order to reduce such complications, a new technique of bone transport involving the use of an external fixator and a locking plate was devised for segmental tibial bone defects. A total of ten patients (nine men, one woman) with a mean age at operation of 40.4 years (16 to 64) underwent distraction osteogenesis with a locking plate to treat previously infected post-traumatic segmental tibial defects. The locking plate was fixed percutaneously to bridge proximal and distal segments, and was followed by external fixation. After docking, percutaneous screws were fixed at the transported segment through plate holes. At the same time, bone grafting was performed at the docking site with the external fixator removed. The mean defect size was 5.9 cm (3.8 to 9.3) and mean external fixation index was 13.4 days/cm (11.8 to 19.5). In all cases, primary union of the docking site and distraction callus was achieved, with an excellent bony result. There was no recurrence of deep infection or osteomyelitis, and with the exception of one patient with a pre-existing peroneal nerve injury, all achieved an excellent or good functional result. With short external fixation times and low complication rates, bone transport with a locking plate could be recommended for patients with segmental tibial defects. Cite this article: Bone Joint J 2013;95-B:1667–72


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1509 - 1514
1 Nov 2007
Zhang X Liu T Li Z Peng W

We present a retrospective study of 27 patients treated by callus distraction using a unilateral external fixator of our own design for nonunion with bone loss and shortening of the femur caused by suppurative osteomyelitis. The unilateral external fixator was used either alone or in combination with an intramedullary nail. The mean age of the patients was 13.6 years (8 to 18). The fixator was used alone in 13 patients and with an intramedullary nail in 14. The bone results at a mean follow-up of 88 months (37 to 144) were excellent in 16 patients and good in 11. The functional results were excellent in 18 patients and good in nine. However, four patients still had draining sinuses at the latest follow-up. A residual deformity greater than 7° was present in seven femora, but this did not adversely affect function or require further treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 788 - 792
1 Jun 2011
Schiedel FM Pip S Wacker S Pöpping J Tretow H Leidinger B Rödl R

We report the results of intramedullary leg lengthening conducted between 2002 and 2009 using the Intramedullary Skeletal Kinetic Distractor in 69 unilateral lengthenings involving 58 femora and 11 tibiae. We identified difficulties that occurred during the treatment and assessed whether they were specifically due to the implant or independent of it. Paley’s classification for evaluating problems, obstacles and complications with external fixators was adopted, and implant-specific difficulties were continuously noted. There were seven failures requiring premature removal of the device, in four due to nail breakage and three for other reasons, and five unsuccessful outcomes after completion of the lengthening. In all, 116 difficulties were noted in 45 patients, with only 24 having problem-free courses. In addition to the difficulties arising from the use of external fixators, there were almost the same number again of implant-specific difficulties. Nevertheless, successful femoral lengthening was achieved in 52 of the 58 patients (90%). However, successful tibial lengthening was only achieved in five of 11 patients (45%)


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1394 - 1399
1 Oct 2009
Oh C Song H Kim J Choi J Min W Park B

Ten patients, who were unsuitable for limb lengthening over an intramedullary nail, underwent lengthening with a submuscular locking plate. Their mean age at operation was 18.5 years (11 to 40). After fixing a locking plate submuscularly on the proximal segment, an external fixator was applied to lengthen the bone after corticotomy. Lengthening was at 1 mm/day and on reaching the target length, three or four screws were placed in the plate in the distal segment and the external fixator was removed. All patients achieved the pre-operative target length at a mean of 4.0 cm (3.2 to 5.5). The mean duration of external fixation was 61.6 days (45 to 113) and the mean external fixation index was 15.1 days/cm (13.2 to 20.5), which was less than one-third of the mean healing index (48 days/cm (41.3 to 55). There were only minor complications. Lengthening with a submuscular locking plate can successfully permit early removal of the fixator with fewer complications and is a useful alternative in children or when nailing is difficult


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 52 - 56
1 Jan 2011
Kocaoglu M Bilen FE Sen C Eralp L Balci HI

We present the results of the surgical correction of lower-limb deformities caused by metabolic bone disease. Our series consisted of 17 patients with a diagnosis of hypophosphataemic rickets and two with renal osteodystrophy; their mean age was 25.6 years (14 to 57). In all, 43 lower-limb segments (27 femora and 16 tibiae) were osteotomised and the deformity corrected using a monolateral external fixator. The segment was then stabilised with locked intramedullary nailing. In addition, six femora in three patients were subsequently lengthened by distraction osteogenesis. The mean follow-up was 60 months (18 to 120). The frontal alignment parameters (the mechanical axis deviation, the lateral distal femoral angle and the medial proximal tibial angle) and the sagittal alignment parameters (the posterior distal femoral angle and the posterior proximal tibial angle) improved post-operatively. The external fixator was removed either at the end of surgery or at the end of the lengthening period, allowing for early mobilisation and weight-bearing. We encountered five problems and four obstacles in the programme of treatment. The use of intramedullary nails prevented recurrence of deformity and refracture


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1322 - 1325
1 Oct 2009
El-Gafary KAM Mostafa KM Al-adly WY

Charcot osteoarthropathy of the foot is a chronic and progressive disease of bone and joint associated with a risk of amputation. The main problems encountered in this process are osteopenia, fragmentation of the bones of the foot and ankle, joint subluxation or even dislocation, ulceration of the skin and the development of deep sepsis. We report our experience of a series of 20 patients with Charcot osteoarthropathy of the foot and ankle treated with an Ilizarov external fixator. The mean age of the group was 30 years (21 to 50). Diabetes mellitus was the underlying cause in 18 patients. Five had chronic ulcers involving the foot and ankle. Each patient had an open lengthening of the tendo Achillis with excision of all necrotic and loose bone from the ankle, subtalar and midtarsal joints when needed. The resulting defect was packed with corticocancellous bone graft harvested from the iliac crest and an Ilizarov external fixator was applied. Arthrodesis was achieved after a mean of 18 weeks (15 to 20), with healing of the skin ulcers. Pin track infection was not uncommon, but no frame had to be removed before the arthrodesis was sound. Every patient was able to resume wearing regular shoes after a mean of 26.5 weeks (20 to 45)


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 634 - 639
1 May 2018
Davda K Heidari N Calder P Goodier D

Aims. The management of a significant bony defect following excision of a diaphyseal atrophic femoral nonunion remains a challenge. We present the outcomes using a combined technique of acute femoral shortening, stabilized with a long retrograde intramedullary nail, accompanied by bifocal osteotomy compression and distraction osteogenesis with a temporary monolateral fixator. Patients and Methods. Eight men and two women underwent the ‘rail and nail’ technique between 2008 and 2016. Proximal locking of the nail and removal of the external fixator was undertaken once the length of the femur had been restored and prior to full consolidation of the regenerate. Results. The mean lengthening was 7 cm (3 to 11). The external fixator was removed at a mean of 127 days (57 to 220). The mean bone healing index was 28 days/cm and the mean external fixation index was 20 days/cm (11 to 18). There were no superficial or deep infections. Conclusion. This small retrospective study shows encouraging results for a combined technique, enabling compression of the femoral osteotomy, alignment, and controlled lengthening. Removal of the fixator and proximal locking of the nail reduces the risk of complications and stabilizes the femur with the maximum working length of the nail. Cite this article: Bone Joint J 2018;100-B:634–9


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 62 - 68
1 Jan 2001
Bhandari M Guyatt GH Swiontkowski MF Schemitsch EH

We have systematically reviewed the effect of alternative methods of stabilisation of open tibial fractures on the rates of reoperation, and the secondary outcomes of nonunion, deep and superficial infection, failure of the implant and malunion by the analysis of 799 citations on the subject, identified from computerised databases. Although 68 proved to be potentially eligible, only eight met all criteria for inclusion. Three investigators independently graded the quality of each study and extracted the relevant data. One study (n = 56 patients) suggested that the use of external fixators significantly decreased the requirement for reoperation when compared with fixation with plates. The use of unreamed nails, compared with external fixators (five studies, n = 396 patients), reduced the risk of reoperation, malunion and superficial infection. Comparison of reamed with unreamed nails showed a reduced risk of reoperation (two studies, n = 132) with the reamed technique. An indirect comparison between reamed nails and external fixators also showed a reduced risk of reoperation (two studies) when using nails. We have identified compelling evidence that unreamed nails reduced the incidence of reoperations, superficial infections and malunions, when compared with external fixators. The relative merits of reamed versus unreamed nails in the treatment of open tibial fractures remain uncertain


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1094 - 1099
1 Aug 2018
Gupta S Malhotra A Mittal N Garg SK Jindal R Kansay R

Aims. The aims of this study were to establish whether composite fixation (rail-plate) decreases fixator time and related problems in the management of patients with infected nonunion of tibia with a segmental defect, without compromising the anatomical and functional outcomes achieved using the classical Ilizarov technique. We also wished to study the acceptability of this technique using patient-based objective criteria. Patients and Methods. Between January 2012 and January 2015, 14 consecutive patients were treated for an infected nonunion of the tibia with a gap and were included in the study. During stage one, a radical debridement of bone and soft tissue was undertaken with the introduction of an antibiotic-loaded cement spacer. At the second stage, the tibia was stabilized using a long lateral locked plate and a six-pin monorail fixator on its anteromedial surface. A corticotomy was performed at the appropriate level. During the third stage, i.e. at the end of the distraction phase, the transported fragment was aligned and fixed to the plate with two to four screws. An iliac crest autograft was added to the docking site and the fixator was removed. Functional outcome was assessed using the Association for the Study and Application of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) score. Results. The mean age of patients was 38.1 years (. sd. 12.7). There were 13 men and one woman. The mean size of the defect was 6.4 cm (. sd. 1.3). the mean follow-up was 33.2 months (24 to 50). The mean external fixator index was 21.2 days/cm (. sd. 1.5). The complication rate was 0.5 (7/14) per patient. According to the classification of Paley, there were five problems and two obstacles but no true complications. The ASAMI bone score was excellent in all patients. The functional ASAMI scores were excellent in eight and good in six patients. The mean MSTS composite score was 83.9% (. sd. 7.1), with an MSTS emotional acceptance score of 4.9 (. sd. 0.5; maximum possible 5). Conclusion. Composite fixation (rail-plate) decreases fixator time and the associated complications, in the treatment of patients of infected nonunion tibia with a segmental defect. It also provides good anatomical and functional results with high emotional acceptance. Cite this article: Bone Joint J 2018;100-B:1094–9


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 283 - 288
1 Feb 2017
Hughes A Heidari N Mitchell S Livingstone J Jackson M Atkins R Monsell F

Aims. Computer hexapod assisted orthopaedic surgery (CHAOS), is a method to achieve the intra-operative correction of long bone deformities using a hexapod external fixator before definitive internal fixation with minimally invasive stabilisation techniques. The aims of this study were to determine the reliability of this method in a consecutive case series of patients undergoing femoral deformity correction, with a minimum six-month follow-up, to assess the complications and to define the ideal group of patients for whom this treatment is appropriate. Patients and Methods. The medical records and radiographs of all patients who underwent CHAOS for femoral deformity at our institution between 2005 and 2011 were retrospectively reviewed. Records were available for all 55 consecutive procedures undertaken in 49 patients with a mean age of 35.6 years (10.9 to 75.3) at the time of surgery. Results. Patients were assessed at a mean interval of 44 months (6 to 90) following surgery. The indications were broad; the most common were vitamin D resistant rickets (n = 10), growth plate arrest (n = 6) and post-traumatic deformity (n = 20). Multi-planar correction was required in 33 cases. A single level osteotomy was performed in 43 cases. Locking plates were used to stabilise the osteotomy in 33 cases and intramedullary nails in the remainder. Complications included two nonunions, one death, one below-knee deep vein thrombosis, one deep infection and one revision procedure due to initial under-correction. There were no neurovascular injuries or incidence of compartment syndrome. Conclusion. This is the largest reported series of femoral deformity corrections using the CHAOS technique. This series demonstrates that precise intra-operative realignment is possible with a hexapod external fixator prior to definitive stabilisation with contemporary internal fixation. This combination allows reproducible correction of complex femoral deformity from a wide variety of diagnoses and age range with a low complication rate. Cite this article: Bone Joint J 2017;99-B:283–8


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1382 - 1388
1 Oct 2016
Laubscher M Mitchell C Timms A Goodier D Calder P

Aims. Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages. Patients and Methods. We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared. Results. In 20 cases (15 patients) the Precice lengthening nail was used and in 13 cases (seven patients) the LRS external fixator system. The desired length was achieved in all cases in the Precice group and in 12 of 13 cases in the LRS group. The mean healing index was 31.3 days/cm in the Precice and 47.1 days/cm in the LRS group (p < 0.001). This was associated with an earlier ability to bear full weight without aids in the Precice group. There were more complications with LRS lengthening, including pin site infections and regenerate deformity. Implant tolerance and the patients’ perception of the cosmetic result were better with the Precice treatment. Conclusion. Femoral lengthening with the Precice femoral nail achieved excellent functional results with fewer complications and greater patient satisfaction when compared with the LRS system in our patients. Cite this article: Bone Joint J 2016;98-B:1382–8


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 109 - 114
1 Jan 2015
Haller JM Holt DC McFadden ML Higgins TF Kubiak EN

The aim of this study was to report the incidence of arthrofibrosis of the knee and identify risk factors for its development following a fracture of the tibial plateau. We carried out a retrospective review of 186 patients (114 male, 72 female) with a fracture of the tibial plateau who underwent open reduction and internal fixation. Their mean age was 46.4 years (19 to 83) and the mean follow-up was16.0 months (6 to 80). A total of 27 patients (14.5%) developed arthrofibrosis requiring a further intervention. Using multivariate regression analysis, the use of a provisional external fixator (odds ratio (OR) 4.63, 95% confidence interval (CI) 1.26 to 17.7, p = 0.021) was significantly associated with the development of arthrofibrosis. Similarly, the use of a continuous passive movement (CPM) machine was associated with significantly less development of arthrofibrosis (OR = 0.32, 95% CI 0.11 to 0.83, p = 0.024). The effect of time in an external fixator was found to be significant, with each extra day of external fixation increasing the odds of requiring manipulation under anaesthesia (MUA) or quadricepsplasty by 10% (OR = 1.10, p = 0.030). High-energy fracture, surgical approach, infection and use of tobacco were not associated with the development of arthrofibrosis. Patients with a successful MUA had significantly less time to MUA (mean 2.9 months; . sd. 1.25) than those with an unsuccessful MUA (mean 4.86 months;. sd. 2.61, p = 0.014). For those with limited movement, therefore, performing an MUA within three months of the injury may result in a better range of movement. . Based our results, CPM following operative fixation for a fracture of the tibial plateau may reduce the risk of the development of arthrofibrosis, particularly in patients who also undergo prolonged provisional external fixation. Cite this article: Bone Joint J 2015;97-B:109–14


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 782 - 787
1 Jun 2011
Sun X Easwar TR Manesh S Ryu J Song S Kim S Song H

We compared the complications and outcome of tibial lengthening using the Ilizarov method with and without the use of a supplementary intramedullary nail. In a retrospective case-matched series assembled from 176 patients with tibial lengthening, we matched 52 patients (26 pairs, group A with nail and group B without) according to the following criteria in order of importance: 1) difference in amount of lengthening (± 2 cm); 2) percentage difference in lengthening (± 5%); 3) difference in patient’s age (± seven years); 4) aetiology of the shortening, and 5) level of difficulty in obtaining the correction. The outcome was evaluated using the external fixator index, the healing index and an outcome score according to the criteria of Paley. It was found that some complications were specific to group A or B respectively, but others were common to both groups. The outcome was generally better in lengthenings with a nail, although there was a higher incidence of rectifiable equinus deformity in these patients


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 232 - 237
1 Feb 2006
Saridis A Panagiotopoulos E Tyllianakis M Matzaroglou C Vandoros N Lambiris E

We reviewed 13 patients with infected nonunion of the distal femur and bone loss, who had been treated by radical surgical debridement and the application of an Ilizarov external fixator. All had severely restricted movement of the knee and a mean of 3.1 previous operations. The mean length of the bony defect was 8.3 cm and no patient was able to bear weight. The mean external fixation time was 309.8 days. According to Paley’s grading system, eight patients had an excellent clinical and radiological result and seven excellent and good functional results. Bony union, the ability to bear weight fully, and resolution of the infection were achieved in all the patients. The external fixation time was increased when the definitive treatment started six months or more after the initial trauma, the patient had been subjected to more than four previous operations and the initial operation had been open reduction and internal fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 783 - 789
1 Jun 2006
Sen C Eralp L Gunes T Erdem M Ozden VE Kocaoglu M

In this retrospective study we evaluated the method of acute shortening and distraction osteogenesis for the treatment of tibial nonunion with bone loss in 17 patients with a mean age of 36 years (10 to 58). The mean bone loss was 5.6 cm (3 to 10). In infected cases, we performed the treatment in two stages. The mean follow-up time was 43.5 months (24 to 96). The mean time in external fixation was 8.0 months (4 to 13) and the mean external fixator index was 1.4 months/cm (1.1 to 1.8). There was no recurrence of infection. The bone evaluation results were excellent in 16 patients and good in one, while functional results were excellent in 15 and good in two. The complication rate was 1.2 per patient. We conclude that acute shortening and distraction osteogenesis is a safe, reliable and successful method for the treatment of tibial nonunion with bone loss, with a shorter period of treatment and lower rate of complication


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 80 - 88
1 Jan 2007
El-Rosasy MA

We have managed 21 patients with a fracture of the tibia complicated by bone and soft-tissue loss as a result of an open fracture in 10, or following debridement of an infected nonunion in 11, by resection of all the devitalised tissues, acute limb shortening to close the defect, application of an external fixator and metaphyseal osteotomy for re-lengthening. The mean bone loss was 4.7 cm (3 to 11). The mean age of the patients was 28.8 years (12 to 54) and the mean follow-up was 34.8 months (24 to 75). All the fractures united with a well-aligned limb. The mean duration of treatment for the ten grade-III A+B open fractures (according to the Gustilo-Anderson classification) was 5.7 months (4.5 to 8) and for the nonunions, 7.6 months (5.5 to 12.5). Complications included one refracture, one transient palsy of the peroneal nerve and one equinus contracture of 10°


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 795 - 800
1 Jun 2008
Liu T Zhang X Li Z Zeng W Peng D Sun C

Nonunion of the humerus with bone loss and shortening due to osteomyelitis is rare but difficult to treat. We describe our experience with a callus distraction technique using a monolateral external fixator for the treatment of this condition. Between October 1994 and January 2004, 11 patients were treated. There were seven males and four females, with a mean age of 14 years (10 to 17). The mean bone loss was 1.9 cm (1 to 2.7) and the mean length discrepancy in the upper limb was 5.6 cm (3.5 to 8.0). The mean follow-up was for 106 months (54 to 166). The mean external fixation index was 34.8 days/cm (29.8 to 40.5). The mean lengthening was 9.5 cm (5.5 to 13.4). There were seven excellent results, three good and one poor. There were nine excellent functional results and two good. The treatment of humeral nonunion with bone loss and shortening due to osteomyelitis by callus distraction is a safe and effective means of improving function and cosmesis


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 540 - 543
1 Apr 2005
Kazuki K Hiroshima K Kawahara K

Deformity of the forearm due to growth disturbance of the ulna occurs in a number of conditions such as ulnar deficiency, multiple exostoses, and neurofibromatosis. We report a previously unrecognised form, caused by focal cortical indentation. We have treated five children with this condition, three girls and two boys; the mean age at presentation was 5 years (2 to 8). The deformity was first recognised about the age of two years, and progressed gradually. The radiological findings were the same in all cases. The focal cortical indentation was seen at the distal end of the ulna with anteromedial bowing and dysplasia. The radial head was dislocated posterolaterally. In one patient the histological findings at the site of indentation were of a fold of tissue resembling periosteum, which interfered with enchondral ossification. Treatment by ulnar lengthening using an external fixator and osteotomy which corrected both the ulnar deformity and reduced the dislocated radial head in two cases gave the best results


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 207 - 211
1 Mar 1987
Jenkins N Jones D Johnson Mintowt-Czyz W

In a prospective, controlled study 58 patients aged under 60 years with Colles' fractures were treated either by a forearm plaster or by the application of an external fixator. In 94% of those treated by a fixator it was possible to insert the distal pins of the frame into the fracture fragment, the fixation obtained being sufficient to forgo additional splintage. The external fixator proved more effective at holding the manipulated position, and the radiological loss of position during fracture union was minimal compared with that seen in patients treated in plaster


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 863 - 866
1 Jun 2005
Nagarajah K Aslam N McLardy Smith P McNally M

We describe a technique of ‘cross-hip distraction’ to reduce a dislocated hip with subsequent reconstruction of the joint for septic arthritis with extensive femoral osteomyelitis. A 27-year-old woman presented with a dislocated, collapsed femoral head and chronic osteomyelitis of the femur. Examination revealed a leg-length discrepancy of 7 cm and an irritable hip. A staged technique was used with primary clearance of osteomyelitis and secondary reconstruction of the hip. A cross-hip monolateral external fixator was used to establish normal anatomy followed by an arthroplasty. A good functional outcome was achieved. The use of cross-hip distraction avoids soft-tissue and nerve damage and achieved improved abductor function before arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1201 - 1207
1 Sep 2009
Lefaivre KA Starr AJ Barker BP Overturf S Reinert CM

We describe our early operative experience with a new pelvic reduction frame and the standard of reduction of fractures of the pelvic ring which we achieved in the first 35 consecutive patients, with 34 acute fractures and one nonunion. The pre-operative and immediate post-operative radiographs were measured, using two methods, to find the maximum radiological displacement of the fracture and the quality of the reduction according to the criteria of Tornetta and Matta. There were 19 vertical shear fractures and 16 compression injuries. The mean age of the patients was 33.5 years (10 to 59) and mean delay to surgery was 4.6 days (0 to 16) in the 34 acute injuries. The mean operative time in isolated procedures was 103.4 minutes (. sd. 6.5). All but one patient had iliosacral screws implanted, 18 had screws in the anterior column, six had plates at the symphysis pubis and 12 had anterior external fixators. The mean maximum horizontal or vertical displacement was improved from 30.8 mm (. sd. 2.7) to a mean of 7.1 mm (. sd. 0.7). The reduction was assessed as excellent in ten patients, good in 18, and fair in the remainder. There was no significant influence on the quality of the reduction caused by obesity (p = 0.34), the type of fracture (p = 0.41) or delay to surgery (p = 0.83). The frame was shown to be effective, allowing the surgeon to obtain a satisfactory reduction and fixation of acute displaced disruptions of the pelvic ring


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 790 - 793
1 Jun 2007
Norrish AR Lewis CP Harrison WJ

Patients infected with HIV presenting with an open fracture of a long bone are difficult to manage. There is an unacceptably high rate of post-operative infection after internal fixation. There are no published data on the use of external fixation in such patients. We compared the rates of pin-track infection in HIV-positive and HIV-negative patients presenting with an open fracture. There were 47 patients with 50 external fixators, 13 of whom were HIV-positive (15 fixators). There were significantly more pin-track infections requiring pharmaceutical or surgical intervention (Checketts grade 2 or greater) in the HIV-positive group (t-test, p = 0.001). The overall rate of severe pin-track infection in the HIV-positive patients requiring removal of the external-fixator pins was 7%. This contrasts with other published data which have shown higher rates of wound infection if open fractures are treated by internal fixation. We recommend the use of external fixation for the treatment of open fractures in HIV-positive patients


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 1000 - 1004
1 Jul 2005
Baumgart R Bürklein D Hinterwimmer S Thaller P Mutschler W

Ollier’s disease is characterised by severe deformity of the extremities and retarded growth because of multiple enchondromas. For correction of deformity, the Ilizarov method has been used although it has many complications. A 17-year-old boy with Ollier’s disease had a limb-length discrepancy of 17.4 cm, with a valgus deformity of the right knee and recurvatum of the femur of 23°. He had undergone three unsuccessful attempts to correct the deformities by using external fixators. We used a fully implantable, motorised, lengthening and correction nail (Fitbone) to achieve full correction of all the deformities without complications. We decided to carry out the procedure in three stages. First, we lengthened the femur by 3.6 cm and the tibia by 4 cm. We then exchanged the femoral nail for a longer implant and achieved a further 6 cm of length. This reduced the shortening to 3.8 cm. When the boy has finished secondary school we will adjust the remaining discrepancy


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1628 - 1633
1 Dec 2015
Elmadag M Uzer G Yildiz F Erden T Bilsel K Büyükpinarbasili N Üsümez A Bozdag E Sen C

This animal study compares different methods of performing an osteotomy, including using an Erbium-doped Yttrium Aluminum Garnet laser, histologically, radiologically and biomechanically. A total of 24 New Zealand rabbits were divided into four groups (Group I: multihole-drilling; Group II: Gigli saw; Group III: electrical saw blade and Group IV: laser). A proximal transverse diaphyseal osteotomy was performed on the right tibias of the rabbits after the application of a circular external fixator. The rabbits were killed six weeks after the procedure, the operated tibias were resected and radiographs taken. . The specimens were tested biomechanically using three-point bending forces, and four tibias from each group were examined histologically. Outcome parameters were the biomechanical stability of the tibias as assessed by the failure to load and radiographic and histological examination of the osteotomy site. . The osteotomies healed in all specimens both radiographically and histologically. The differences in the mean radiographic (p = 0.568) and histological (p = 0.71) scores, and in the mean failure loads (p = 0.180) were not statistically significant between the groups. . Different methods of performing an osteotomy give similar quality of union. The laser osteotomy, which is not widely used in orthopaedics is an alternative to the current methods. Cite this article: Bone Joint J 2015;97-B:1628–33


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1077 - 1083
1 Aug 2007
Tsuchiya H Morsy AF Matsubara H Watanabe K Abdel-Wanis ME Tomita K

We present a retrospective study of patients suffering from a variety of benign tumours in whom external fixators were used to treat deformity and limb-length discrepancy, and for the reconstruction of bone defects. A total of 43 limbs in 31 patients (12 male and 19 female) with a mean age of 14 years (2 to 54) were treated. The diagnosis was Ollier’s disease in 12 limbs, fibrous dysplasia in 11, osteochondroma in eight, giant cell tumour in five, osteofibrous dysplasia in five and non-ossifying fibroma in two. The lesions were treated in the tibia in 19 limbs, in the femur in 16, and in the forearm in eight. The Ilizarov frame was used in 25 limbs, the Taylor Spatial Frame in seven, the Orthofix fixator in six, the Monotube in four and the Heidelberg fixator in one. The mean follow-up was 72 months (22 to 221). The mean external fixation period was 168 days (71 to 352). The mean external fixation index was 42 days/cm (22.2 to 102.0) in the 22 patients who required limb lengthening. The mean correction angle for those with angular deformity was 23° (7° to 45°). At final follow-up all patients had returned to normal activities. Four patients required a second operation for recurrent deformity of further limb lengthening. Local recurrence occurred in one patient, requiring further surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 557 - 564
1 Apr 2009
Rumian AP Draper ERC Wallace AL Goodship AE

An understanding of the remodelling of tendon is crucial for the development of scientific methods of treatment and rehabilitation. This study tested the hypothesis that tendon adapts structurally in response to changes in functional loading. A novel model allowed manipulation of the mechanical environment of the patellar tendon in the presence of normal joint movement via the application of an adjustable external fixator mechanism between the patella and the tibia in sheep, while avoiding exposure of the patellar tendon itself. Stress shielding caused a significant reduction in the structural and material properties of stiffness (79%), ultimate load (69%), energy absorbed (61%), elastic modulus (76%) and ultimate stress (72%) of the tendon compared with controls. Compared with the material properties the structural properties exhibited better recovery after re-stressing with stiffness 97%, ultimate load 92%, energy absorbed 96%, elastic modulus 79% and ultimate stress 80%. The cross-sectional area of the re-stressed tendons was significantly greater than that of stress-shielded tendons. The remodelling phenomena exhibited in this study are consistent with a putative feedback mechanism under strain control. This study provides a basis from which to explore the interactions of tendon remodelling and mechanical environment


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 448 - 451
1 May 1991
Thakur A Patankar J

Seventy-nine open tibial fractures were treated with unilateral uniplanar tubular external fixators. Excellent stability allowed early weight-bearing. All comminuted fractures, with or without bone loss, and some transverse or short oblique fractures with intermediate fragments were treated by early bone grafting through a posterolateral approach. The external fixator was dynamised as soon as periosteal callus was seen on the radiograph. Bone healing times ranged from 11 to 40 weeks (mean 20). Significant ankle stiffness occurred in 10.9% and leg shortening in 2.8%. Pin track infection was seen in 45.2% but was easily controlled with standard management. The external fixation frame allowed excellent functional freedom for Oriental patients to sit cross-legged and squat. Combined with early bone grafting, external fixation is an excellent method for the management of open tibial fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 259 - 265
1 Mar 2004
Saldanha KAN Saleh M Bell MJ Fernandes JA

We performed limb lengthening and correction of deformity of nine long bones of the lower limb in six children (mean age, 14.7 years) with osteogenesis imperfecta (OI). All had femoral lengthening and three also had ipsilateral tibial lengthening. Angular deformities were corrected simultaneously. Five limb segments were treated using a monolateral external fixator and four with the Ilizarov frame. In three children, lengthening was done over previously inserted femoral intramedullary rods. The mean lengthening achieved was 6.26 cm (mean healing index, 33.25 days/cm). Significant complications included one deep infection, one fracture of the femur and one anterior angulation deformity of the tibia. The abnormal bone of OI tolerated the external fixators throughout the period of lengthening without any episodes of migration of wires or pins through the soft bone. The regenerate bone formed within the time which is normally expected in limb-lengthening procedures performed for other conditions. We conclude that despite the abnormal bone characteristics, distraction osteogenesis to correct limb-length discrepancy and angular deformity can be performed safely in children with OI


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1472 - 1477
1 Nov 2009
Lee W Yoo JH Moon J

We carried out a retrospective study to assess the clinical results of lengthening the fourth metatarsal in brachymetatarsia in 153 feet of 106 patients (100 female, six males) using three different surgical techniques. In one group lengthening was performed by one-stage intercalary bone grafting secured by an intramedullary Kirschner-wire (45 feet, 35 patients). In the second group lengthening was obtained gradually using a mini-external fixator after performing an osteotomy with a saw (59 feet, 39 patients) and in the third group lengthening was achieved in a gradual manner using a mini-external fixator after undertaking an osteotomy using osteotome through pre-drilled holes (49 feet, 32 patients). The mean age of the patients was 26.3 years (13 to 48). Pre-operatively, the fourth ray of the bone-graft group was longer than that of other two groups (p < 0.000). The clinical outcome was compared in the three groups. The mean follow-up was 22 months (7 to 55). At final follow-up, the mean lengthening in the bone-graft group was 13.9 mm (3.5 to 23.0, 27.1%) which was less than that obtained in the saw group with a mean of 17.8 mm (7.0 to 33.0, 29.9%) and in the pre-drilled osteotome group with a mean of 16.8 mm (6.5 to 28.0, 29.4%, p = 0.001). However, the mean time required for retention of the fixation in the bone-graft group was the shortest of the three groups. Patients were dissatisfied with the result for five feet (11.1%) in the bone-graft group, eight (13.6%) in the saw group and none in the pre-drilled osteotomy group (p < 0.000). The saw group included eight feet with failure of bone formation after surgery. Additional operations were performed in 20 feet because of stiffness (n = 7, all groups), failure of bone formation (n = 4, saw group), skin maceration (n = 4, bone-graft group), malunion (n = 4, bone-graft and saw groups) and breakage of the external fixator (n = 1, saw group). We conclude that the gradual lengthening by distraction osteogenesis after osteotomy using an osteotome produces the most reliable results for the treatment of fourth brachymetatarsia


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 721 - 729
1 May 2005
Yanai T Ishii T Chang F Ochiai N

We produced large full-thickness articular cartilage defects in 33 rabbits in order to evaluate the effect of joint distraction and autologous culture-expanded bone-marrow-derived mesenchymal cell transplantation (ACBMT) at 12 weeks. After fixing the knee on a hinged external fixator, we resected the entire surface of the tibial plateau. We studied three groups: 1) with and without joint distraction; 2) with joint distraction and collagen gel, and 3) with joint distraction and ACBMT and collagen gel. The histological scores were significantly higher in the groups with ACBMT collagen gel (p < 0.05). The area of regenerated soft tissue was smaller in the group allowed to bear weight (p < 0.05). These findings suggest that the repair of large defects of cartilage can be enhanced by joint distraction, collagen gel and ACBMT


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 868 - 875
1 Aug 2004
Okcu G Aktuglu K

We retrospectively reviewed 60 fractures of the tibial plafond treated by either an ankle-sparing diaphyseal-epiphyseal technique using the Ilizarov ring fixator or by an ankle-spanning technique using a monolateral articulated external fixator. The Ilizarov ring fixator was applied in 24 fractures and the monolateral articulated transarticular external fixator in 20. Both techniques were combined with limited open reduction and internal fixation of the articular surface if necessary. Between three and nine years after the injury, all patients returned for clinical and radiological assessment and evaluation of ankle function using the modified Mazur score. There were no significant differences between the two groups in terms of age, gender, mechanism of injury, type of fracture or length of follow-up. The mean functional ankle score was 86 points for the Ilizarov group and 82 points for the articulated fixator group. The difference was not significant (p = 0.07). There were no significant differences between the groups with regard to the radiographic score and late complications. Patients treated with the Ilizarov ring fixator had significantly better ankle and subtalar movement. We conclude that both techniques of external fixation are satisfactory methods of treatment for fractures of the tibial plafond, but that the total arc of movement of the joint is preserved better without bridging the ankle


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 206 - 209
1 Feb 2007
Houshian S Chikkamuniyappa C Schroeder H

We present the outcome of the treatment of chronic post-traumatic contractures of the proximal interphalangeal joint by gradual distraction correction using an external fixator. A total of 30 consecutive patients with a mean age of 34 years (17 to 54) had distraction for a mean of 16 days (10 to 22). The fixator was removed after a mean of 29 days (16 to 40). Assessment at a mean of 34 months (18 to 54) after completion of treatment showed that the mean active range of movement had significantly increased by 63° (30° to 90°; p < 0.001). The mean active extension gained was 47° (30° to 75°). Patients aged less than 40 years fared slightly better with a mean gain in active range of movement of 65° (30° to 90°) compared with those aged more than 40 years, who had a mean gain in active range of movement of 55° (30° to 70°) but the difference was not statistically significant (p = 0.148). The use of joint distraction to correct chronic flexion contracture of the proximal interphalangeal joint is a minimally-invasive and effective method of treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 989 - 993
1 Jul 2012
Monsell FP Howells NR Lawniczak D Jeffcote B Mitchell SR

Between 2005 and 2010 ten consecutive children with high-energy open diaphyseal tibial fractures were treated by early reduction and application of a programmable circular external fixator. They were all male with a mean age of 11.5 years (5.2 to 15.4), and they were followed for a mean of 34.5 months (6 to 77). Full weight-bearing was allowed immediately post-operatively. The mean time from application to removal of the frame was 16 weeks (12 to 21). The mean deformity following removal of the frame was 0.15° (0° to 1.5°) of coronal angulation, 0.2° (0° to 2°) sagittal angulation, 1.1 mm (0 to 10) coronal translation, and 0.5 mm (0 to 2) sagittal translation. All patients achieved consolidated bony union and satisfactory wound healing. There were no cases of delayed or nonunion, compartment syndrome or neurovascular injury. Four patients had a mild superficial pin site infection; all settled with a single course of oral antibiotics. No patient had a deep infection or re-fracture following removal of the frame. The time to union was comparable with, or better than, other published methods of stabilisation for these injuries. The stable fixator configuration not only facilitates management of the accompanying soft-tissue injury but enables anatomical post-injury alignment, which is important in view of the limited remodelling potential of the tibia in children aged > ten years. Where appropriate expertise exists, we recommend this technique for the management of high-energy open tibial fractures in children


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 897 - 903
1 Jul 2011
Bachhal V Sankhala SS Jindal N Dhillon MS

We report the outcome of 32 patients (37 knees) who underwent hemicallostasis with a dynamic external fixator for osteoarthritis of the medial compartment of the knee. There were 16 men (19 knees) and 16 women (18 knees) with a mean age at operation of 54.6 years (27 to 72). The aim was to achieve a valgus overcorrection of 2° to 8° or mechanical axis at 62.5% (± 12.5%). At a mean follow-up of 62.8 months (51 to 81) there was no change in the mean range of movement, and no statistically significant difference in the Insall-Salvati index or tibial slope (p = 0.11 and p = 0.15, respectively). The mean hip-knee-ankle angle changed from 190.6 (183° to 197°) to 176.0° (171° to 181°), with a mean final position of the mechanical axis of 58.5% (35.1% to 71.2%). The desired alignment was attained in 31 of 37 (84%) knees. There were 21 excellent, 13 good, two fair and one poor result according to the Oxford knee score with no correlation between age and final score. This score was at its best at one year with a statistically significant deterioration at two years (p = 0.001) followed by a small but not statistically significant deterioration until the final follow-up (p = 0.17). All the knees with Ahlback grade 1 osteoarthritis had excellent or good results. Complications included pin tract infections involving 16.4% of all pins used, delayed union in two, knee stiffness in four, fracture of the lateral cortex in one and ring sequestrum in one. In conclusion, hemicallostasis provides precision in attaining the desired alignment without interfering with tibial slope or patellar height, and is relatively free of serious complications


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1550 - 1555
1 Nov 2011
Hill RA Ibrahim T Mann HA Siapkara A

We present our experience of forearm lengthening in children with various conditions performed by a single surgeon between 1995 and 2009. A total of 19 children with a mean age of 9.8 years (2.1 to 15.9) at the time of surgery had 22 forearm lengthenings using either an Ilizarov/spatial and Ilizarov circular frame or a monolateral external fixator. The patients were divided into two groups: group A, in whom the purpose of treatment was to restore the relationship between the radius and the ulna, and group B, in whom the objective was to gain forearm length. The mean follow-up after removal of the frame was 26 months (13 to 53). There were ten patients (11 forearms) in group A with a mean radioulnar discrepancy of 2.4 cm (1.5 to 3.3) and nine patients (11 forearms) in group B. In group A, the mean lengthening achieved was 2.7 cm (1.0 to 5.5), with a lengthening index of 11.1 weeks/cm. Equalisation or overcorrection of the discrepancy was achieved in seven of 11 forearms, but lengthening was only partially successful at preventing subluxation or dislocation of the radial head. In group B, the mean lengthening achieved was 3.8 cm (1.9 to 6.8), with a lengthening index of 7.25 weeks/cm. Common complications in both groups were pin-site infection and poor regenerate formation. Forearm lengthening by distraction osteogenesis is a worthwhile procedure in children that can improve cosmesis and function, particularly in patients with shortening of both radius and ulna


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 799 - 806
1 Jun 2006
Jones D Parkinson S Hosalkar HS

We reviewed retrospectively 45 patients (46 procedures) with bladder exstrophy treated by bilateral oblique pelvic osteotomy in conjunction with genitourinary repair. The operative technique and post-operative management with or without external fixation are described. A total of 21 patients attended a special follow-up clinic and 24 were interviewed by telephone. The mean follow-up time was 57 months (24 to 108). Of the 45 patients, 42 reported no pain or functional disability, although six had a waddling gait and two had marked external rotation of the hip. Complications included three cases of infection and loosening of the external fixator requiring early removal with no deleterious effect. Mid-line closure failed in one neonate managed in plaster. This patient underwent a successful revision procedure several months later using repeat osteotomies and external fixation. The percentage pubic approximation was measured on anteroposterior radiographs pre-operatively, post-operatively and at final follow-up. The mean approximation was 37% (12% to 76%). It varied markedly with age and was better when external fixation was used. The wide range reflects the inability of the anterior segment to develop naturally in spite of close approximation at operation. We conclude that bilateral oblique pelvic osteotomy with or without external fixation is useful in the management of difficult primary closure in bladder exstrophy, failed primary closure and secondary reconstruction


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 361 - 366
1 Mar 2009
Kovoor CC Padmanabhan V Bhaskar D George VV Viswanath S

We present the results of ankle fusion using the Ilizarov technique for bone loss around the ankle in 20 patients. All except one had sustained post-traumatic bone loss. Infection was present in 17. The mean age was 33.1 years (7 to 71). The mean size of the defect was 3.98 cm (1.5 to 12) and associated limb shortening before the index procedure varied from 1 cm to 5 cm. The mean time in the external fixator was 335 days (42 to 870). Tibiotalar fusion was performed in 19 patients and tibiocalcaneal fusion in one. Associated problems included diabetes in one patient, pelvic and urethral injury in one, visual injury in one patient and ipsilateral tibial fracture in five. At the final mean follow-up of 51.55 months (24 to 121) fusion had been achieved in 19 of 20 patients. A total of 16 patients were able to return to work. The results were graded as good in 11 patients, fair in six and poor in three. The mean external fixation index was 8.8 days/mm (0 to 30). One patient with diabetes developed severe infection which required early removal of the fixator. Refractures occurred in three patients, two of which were at the site of fusion and one at a previous tibial shaft fracture site. Equinus deformity of the ankle fusion occurred after a further fracture in one patient. There were two patients with residual forefoot equinus, and one developed late valgus at the fusion site. Poor consolidation of the regenerated bone in two patients was treated by bone grafting in one and by bone and fibular strut grafting in the other. Residual soft-tissue infection was still present in two patients


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 88 - 96
1 Jan 2023
Vogt B Rupp C Gosheger G Eveslage M Laufer A Toporowski G Roedl R Frommer A

Aims

Distraction osteogenesis with intramedullary lengthening devices has undergone rapid development in the past decade with implant enhancement. In this first single-centre matched-pair analysis we focus on the comparison of treatment with the PRECICE and STRYDE intramedullary lengthening devices and aim to clarify any clinical and radiological differences.

Methods

A single-centre 2:1 matched-pair retrospective analysis of 42 patients treated with the STRYDE and 82 patients treated with the PRECICE nail between May 2013 and November 2020 was conducted. Clinical and lengthening parameters were compared while focusing radiological assessment on osseous alterations related to the nail’s telescopic junction and locking bolts at four different stages.


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1073 - 1080
1 Sep 2022
Winstanley RJH Hadfield JN Walker R Bretherton CP Ashwood N Allison K Trompeter A Eardley WGP

Aims

The Open-Fracture Patient Evaluation Nationwide (OPEN) study was performed to provide clarity in open fracture management previously skewed by small, specialist centre studies and large, unfocused registry investigations. We report the current management metrics of open fractures across the UK.

Method

Patients admitted to hospital with an open fracture (excluding phalanges or isolated hand injuries) between 1 June 2021 and 30 September 2021 were included. Institutional information governance approval was obtained at the lead site and all data entered using Research Electronic Data Capture software. All domains of the British Orthopaedic Association Standard for Open Fracture Management were recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 751 - 758
1 Jul 2024
Yaxier N Zhang Y Song J Ning B

Aims

Given the possible radiation damage and inaccuracy of radiological investigations, particularly in children, ultrasound and superb microvascular imaging (SMI) may offer alternative methods of evaluating new bone formation when limb lengthening is undertaken in paediatric patients. The aim of this study was to assess the use of ultrasound combined with SMI in monitoring new bone formation during limb lengthening in children.

Methods

In this retrospective cohort study, ultrasound and radiograph examinations were performed every two weeks in 30 paediatric patients undergoing limb lengthening. Ultrasound was used to monitor new bone formation. The number of vertical vessels and the blood flow resistance index were compared with those from plain radiographs.


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1095 - 1100
1 Sep 2022
McNally MA Ferguson JY Scarborough M Ramsden A Stubbs DA Atkins BL

Aims

Excision of chronic osteomyelitic bone creates a dead space which must be managed to avoid early recurrence of infection. Systemic antibiotics cannot penetrate this space in high concentrations, so local treatment has become an attractive adjunct to surgery. The aim of this study was to present the mid- to long-term results of local treatment with gentamicin in a bioabsorbable ceramic carrier.

Methods

A prospective series of 100 patients with Cierny-Mader Types III and IV chronic ostemyelitis, affecting 105 bones, were treated with a single-stage procedure including debridement, deep tissue sampling, local and systemic antibiotics, stabilization, and immediate skin closure. Chronic osteomyelitis was confirmed using strict diagnostic criteria. The mean follow-up was 6.05 years (4.2 to 8.4).


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 449 - 454
15 Mar 2023
Zhang C Wang C Duan N Zhou D Ma T

Aims

The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN).

Methods

The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 795 - 800
1 Jul 2023
Parsons N Achten J Costa ML

Aims

To report the outcomes of patients with a fracture of the distal tibia who were treated with intramedullary nail versus locking plate in the five years after participating in the Fixation of Distal Tibia fracture (FixDT) trial.

Methods

The FixDT trial reported the results for 321 patients randomized to nail or locking plate fixation in the first 12 months after their injury. In this follow-up study, we report the results of 170 of the original participants who agreed to be followed up until five years. Participants reported their Disability Rating Index (DRI) and health-related quality of life (EuroQol five-dimension three-level questionnaire) annually by self-reported questionnaire. Further surgical interventions related to the fracture were also recorded.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 412 - 414
1 May 1991
Lammens J Mukherjee A Van Eygen P Fabry G

A case of osteogenesis imperfecta, presenting with bowed deformity of both forearm bones and dislocation of the radial head was treated by separate elongation of both bones using Ilizarov's external fixator


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 302 - 308
1 Feb 2022
Dala-Ali B Donnan L Masterton G Briggs L Kauiers C O’Sullivan M Calder P Eastwood DM

Aims

Osteofibrous dysplasia (OFD) is a rare benign lesion predominantly affecting the tibia in children. Its potential link to adamantinoma has influenced management. This international case series reviews the presentation of OFD and management approaches to improve our understanding of OFD.

Methods

A retrospective review at three paediatric tertiary centres identified 101 cases of tibial OFD in 99 patients. The clinical records, radiological images, and histology were analyzed.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 277 - 285
1 Mar 2024
Pinto D Hussain S Leo DG Bridgens A Eastwood D Gelfer Y

Aims

Children with spinal dysraphism can develop various musculoskeletal deformities, necessitating a range of orthopaedic interventions, causing significant morbidity, and making considerable demands on resources. This systematic review aimed to identify what outcome measures have been reported in the literature for children with spinal dysraphism who undergo orthopaedic interventions involving the lower limbs.

Methods

A PROSPERO-registered systematic literature review was performed following PRISMA guidelines. All relevant studies published until January 2023 were identified. Individual outcomes and outcome measurement tools were extracted verbatim. The measurement tools were assessed for reliability and validity, and all outcomes were grouped according to the Outcome Measures Recommended for use in Randomized Clinical Trials (OMERACT) filters.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 362 - 366
1 May 1984
Wade P Denham R

Arthrodesis of the knee is sometimes needed for failed total knee replacement, but fusion can be difficult to obtain. We describe a method of arthrodesis that uses the simple, inexpensive, Portsmouth external fixator. Bony union was obtained in all six patients treated with this technique. These results are compared with those obtained by other methods of arthrodesis


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 906 - 908
1 Nov 1994
Saleh M Howard A

Broad, depressed pin-site scars often remain after the use of external fixators. We describe a new method of surgical revision which combines W-plasty to break up the outline of the scar, with burial of a dermal island to improve the surface contour. We obtained excellent results with this technique in five patients (19 scars)


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 592 - 596
1 Jul 1993
de Pablos J Franzreb M

We have treated 12 adolescent patients with idiopathic tibia vara by asymmetrical physeal distraction using a modified Wagner external fixator. There were no major complications and a mean correction of 13 degrees was achieved. The main advantages of the technique are that no osteotomy, internal fixation or bone graft is needed, and that the operation can be performed on both tibiae simultaneously. No shortening is produced and lengthening can be added to angular correction if required


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 801 - 804
1 Sep 1990
Court-Brown C Wheelwright E Christie J McQueen M

An analysis of 51 type III open tibial fractures treated by external skeletal fixation is presented. The fractures are subdivided according to the classification of Gustilo, Mendoza and Williams (1984) into types IIIa, IIIb and IIIc. The different prognoses of these fracture subtypes is examined. The use of the Hoffmann and Hughes external fixators in the management of type III open tibial fractures is presented and it is suggested that the prognosis is independent of the type of fixator used


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 302 - 306
1 Mar 1991
Jakim I Pieterse H Sweet M

In a prospective study of 132 patients with an average age of 35 years, unstable intra-articular fractures of the distal radius were treated by external fixator. Only 15 cases required limited open reduction. Follow-up was for a mean of 42 months. There were few complications and 83% of patients had good or excellent results. There was a statistically significant correlation between the severity of the fracture and the clinical outcome, irrespective of radiological restoration. Articular and soft-tissue damage following violent compressive forces may lead to a degree of functional impairment


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 955 - 958
1 Nov 1997
Takakura Y Tanaka Y Fujii T Tamai S

We lengthened seven first metatarsals in four patients with short great toes by callus distraction using an external fixator. Good clinical and cosmetic results were obtained. Bone lengthening is effective in patients with short great toes not only for cosmesis, but also to relieve pain and callosities on the plantar aspect of the second and third metatarsal heads. Excessive lengthening of the first metatarsal resulted in limitation of the range of movement of the metatarsophalangeal joint of the great toe. To prevent this the amount of lengthening should not exceed 40% of the preoperative length of the metatarsal


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 449 - 451
1 May 1999
Magyar G Toksvig-Larsen S Lindstrand A

We studied the complications after open-wedge osteotomy by hemicallotasis in 308 consecutive patients, most of whom had osteoarthritis of the knee. The participating surgeons, who worked at 17 hospitals, used their discretion in selecting patients, operating techniques and external fixators. The general complications included 11 cases of deep-vein thrombosis (4%), six of nonunion (2%) and one of septic arthritis of the knee. There were technical complications in 13 patients (4%). In 157 patients (51%) pin-site infections were recorded; of these, 96% were minor and responded to wound toilet and antibiotic treatment. A total of 18 revision procedures was carried out


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 126 - 129
1 Jan 1998
Citron N Messina JC

In 13 patients (18 fingers) we used two types of external fixator as progressive static splints for the preoperative correction of the deformities of severe Dupuytren’s disease before conventional fasciectomy. The duration of treatment was from one to four weeks. At a mean follow-up of 18 months the mean total fixed flexion deficit had been reduced from 138° to 39° and the mean proximal interphalangeal joint contracture from 80° to 29°. The mean total active range of movement had increased from 123° to 175°. These preliminary results are promising, but continued follow-up is needed since recurrence is common


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1611 - 1618
1 Oct 2021
Kavarthapu V Budair B

Aims

In our unit, we adopt a two-stage surgical reconstruction approach using internal fixation for the management of infected Charcot foot deformity. We evaluate our experience with this functional limb salvage method.

Methods

We conducted a retrospective analysis of prospectively collected data of all patients with infected Charcot foot deformity who underwent two-stage reconstruction with internal fixation between July 2011 and November 2019, with a minimum of 12 months’ follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 602 - 607
1 Jul 1995
Magnan B Bragantini A Regis D Bartolozzi P

Congenital or acquired shortness of a metatarsal may cause pain in adjacent metatarsals. From 1983 to 1990, we performed nine metatarsal lengthenings in seven adolescent patients by metaphyseal osteotomy followed by gradual distraction of callus (callotasis). Two patients required bone grafts after the lengthening. We used a rigid, unilateral external fixator designed for use in the hand and foot. At follow-up, from three to ten years later, healing had been achieved in all with an average healing index of 50 days/cm, and metatarsalgia had been relieved by the restoration of correct metatarsal length


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 561 - 565
1 Aug 1986
Pritchett J

Deformity of the forearm is common in patients with hereditary multiple exostoses, producing cosmetic and functional impairment in which shortening of the ulna is a significant factor. The results of ulnar lengthening in 10 forearms of eight patients are reported. Lengthening was performed by osteotomy of the shaft followed immediately by a bone graft and internal fixation, or by gradual distraction with an external fixator. In all patients the appearance was improved and the range of radial deviation at the wrist was increased. In most patients forearm movement and radial head stability were improved. Partial recurrence of the deformity was seen during the follow-up of skeletally immature patients, but in general ulnar lengthening was found to be a useful operation


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 1014 - 1019
1 Nov 1998
Bain GI Mehta JA Heptinstall RJ Bria M

Pain, stiffness, instability and degenerative arthritis are common sequelae of complex fracture-dislocations of the proximal interphalangeal (PIP) joint. Operations were carried out to obtain stability, followed by application of a dynamic external fixator in 20 patients with a mean age of 29 years. This provided stability and distraction, and allowed controlled passive movement. Most (70%) of the patients had a chronic lesion and the mean time from injury to surgery was 215 days (3 to 1953). The final mean range of movement was 12 to 86°. Complications included redislocation and septic arthritis, which affected the outcome. Four pin-track infections and two breakages of the hinge did not influence the result. The PIP Compass hinge is a useful adjunct to surgical reconstruction of the injured PIP joint


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 428 - 432
1 May 1997
Cannegieter DM Juttmann JW

We present a prospective study of the treatment of 32 unstable Colles’ fractures by external fixation and cancellous grafting with minimal exposure. We inserted an external fixator between the radius and the second metacarpal, and maintained ligamentotaxis for five weeks. In 27 patients the result was good or excellent, but five fractures healed with malunion. All patients made a satisfactory functional recovery. At a mean follow-up of three years (1 to 5) after injury none had pain in the wrist and all were satisfied with the result. The average grip strength was 95% of normal. Seven patients had algodystrophy with mild impairment of finger movements in four. We conclude that the combination of cancellous grafting and external fixation is effective for the treatment of unstable Colles’ fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 547 - 550
1 May 2001
Exner GU

Two consecutive cases of chronic dislocation of the head of the radius after missed Bado type-I Monteggia lesions are presented. Reduction was successfully achieved in both patients after ulnar corticotomy, gradual lengthening and angulation of the ulna using an external fixator. Open reduction or reconstruction of the radio-ulnar capitellar joint was not undertaken. The age at injury was seven years in the older and two years in the younger patient. The time from injury to treatment was five years in the older and three months in the younger child. At follow-up, nine years after completion of treatment in the older and eight months in the younger patient, both show satisfactory movement, function of the forearm and reduction of the head of the radius. This technique may be considered in missed Monteggia lesions before open procedures on the radio-ulnar capitellar joint are undertaken


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1160 - 1167
1 Jun 2021
Smith JRA Fox CE Wright TC Khan U Clarke AM Monsell FP

Aims

Open tibial fractures are limb-threatening injuries. While limb loss is rare in children, deep infection and nonunion rates of up to 15% and 8% are reported, respectively. We manage these injuries in a similar manner to those in adults, with a combined orthoplastic approach, often involving the use of vascularised free flaps. We report the orthopaedic and plastic surgical outcomes of a consecutive series of patients over a five-year period, which includes the largest cohort of free flaps for trauma in children to date.

Methods

Data were extracted from medical records and databases for patients with an open tibial fracture aged < 16 years who presented between 1 May 2014 and 30 April 2019. Patients who were transferred from elsewhere were excluded, yielding 44 open fractures in 43 patients, with a minimum follow-up of one year. Management was reviewed from the time of injury to discharge. Primary outcome measures were the rate of deep infection, time to union, and the Modified Enneking score.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 977 - 983
1 Sep 2000
Patel VR Menon DK Pool RD Simonis RB

We used the Ilizarov circular external fixator to treat 16 patients with persistent nonunion of the diaphysis of the humerus despite surgical treatment. All patients had pain and severe functional impairment of the affected arm. In ten, nonunion followed intramedullary nailing. We successfully treated these by a closed technique. The nail was left in place and the fracture compressed over it. The fractures of the other six patients had previously been fixed by various methods. We explored these nonunions, removed the fixation devices and excised fibrous tissue and dead bone before stabilising with the Ilizarov fixator. In five patients union was achieved. Bone grafting was not required. In the single patient in whom treatment failed, there had been a severely comminuted open fracture. All except one patient had reduction of pain, and all reported an improvement in function


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 307 - 311
1 Mar 1991
Roumen R Hesp W Bruggink E

We report the results of a prospective randomised controlled trial of the management of 101 Colles' fractures in patients over the age of 55 years. Within two weeks of initial reduction 43 fractures had displaced with either more than 10 degrees dorsal angulation or more than 5 mm radial shortening. These patients were randomly divided into two groups: 21 were remanipulated and held by an external fixator; in the control group of 22 patients, the redisplacement was accepted and conservative treatment was continued. Patients treated with external fixation had a good anatomical result, but their function was no better than that of the control group. We found no correlation between final anatomical and functional outcome, and concluded that the severity of the original soft-tissue injury and its complications are the major determinants of functional end result


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 838 - 842
1 Nov 1989
Leung K Shen W Leung P Kinninmonth A Chang J Chan G

The conventional treatment of comminuted fractures in the distal radius has been unsatisfactory. We therefore made a prospective study using the principle of ligamentotoxis and primary cancellous bone grafting as the uniform method of treatment. Ligamentotaxis was maintained by using an external fixator for three weeks only, after which a carefully monitored programme of rehabilitation was given. We have reviewed 72 consecutive distal radial fractures after a follow-up of 7 to 40 months (average 11 months). Reduction had been maintained during healing and over 80% of patients regained full range of movement in hands, wrists and forearms with strong and pain-free wrist function. Complications were infrequent and gave no real problems. We conclude that distraction, external fixation and bone grafting appears to be an excellent method of treating comminuted fractures of the distal radius


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 533 - 535
1 May 2001
Wade RH Moorcroft CI Thomas PBM

We have studied the progression of healing in 103 unstable fractures of the tibia. In 76 patients we removed the external fixator once the stiffness had reached 15 Nm/° in the sagittal plane. Deformity at the site of the fracture subsequently occurred in four patients. In a further 27, we measured stiffness in several planes and removed the fixator only when the stiffness reached 15 Nm/° in each. We found that stiffness in two orthogonal planes may differ widely (maximum difference 9.0 Nm/°, mean 4.1 Nm/°). There were no failures in the second group. We advocate that fracture stiffness be measured in two orthogonal planes when assessing tibial healing and suggest that values above 15 Nm/° in two planes give an indication that it is safe to remove the fixator


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 703 - 708
1 Jun 2022
Najefi A Zaidi R Chan O Hester T Kavarthapu V

Aims

Surgical reconstruction of deformed Charcot feet carries a high risk of nonunion, metalwork failure, and deformity recurrence. The primary aim of this study was to identify the factors contributing to these complications following hindfoot Charcot reconstructions.

Methods

We retrospectively analyzed patients who underwent hindfoot Charcot reconstruction with an intramedullary nail between January 2007 and December 2019 in our unit. Patient demographic details, comorbidities, weightbearing status, and postoperative complications were noted. Metalwork breakage, nonunion, deformity recurrence, concurrent midfoot reconstruction, and the measurements related to intramedullary nail were also recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 178 - 182
1 Mar 2002
Cook RE Keating JF Gillespie I

In a series of 150 consecutive patients with unstable fractures of the pelvis, angiography was performed in 23 (15%) who had uncontrolled hypotension. There were three anteroposterior compression (APC), eight lateral compression (LC) and 12 vertical shear (VS) injuries. Arterial sources of haemorrhage were identified in 18 (78%) patients and embolisation was performed. Angiography was required in 28% of VS injuries. The morphology of the fracture was not a reliable guide to the associated vascular injury. Ten (43%) patients died, of whom six had had angiography as the first therapeutic intervention. Five of these had a fracture which was associated with an increase in pelvic volume (APC or VS) which could have been stabilised by an external fixator. Based on our findings we recommend skeletal stabilisation and, if indicated, laparotomy to deal with sources of intraperitoneal blood loss before pelvic angiography. Embolisation of pelvic arterial bleeding is a worthwhile procedure in patients with hypotension which is unresponsive to these interventions


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 385 - 389
1 May 1985
Vaughan P Lui S Harrington I Maistrelli G

The Roger Anderson external fixator was used in the treatment of unstable fractures of the distal radius in 52 patients, and the results evaluated after a follow-up averaging 58 months. The indications for its use were failure to maintain adequate closed reduction using plaster, and instability of the fracture as determined by the initial radiographs. Our radiological criteria for instability included dorsal angulation of more than 20 degrees, fractures involving the joint, radial shortening of more than 10 mm, and severe dorsal comminution. Using the Lucas modification of the Sarmiento demerit point-rating system, we found that 46 patients (89%) had good or excellent results and six (11%) were classified as fair. There were no poor results. Seven patients (14%) developed complications. None of these affected the long-term results except in one elderly woman where the pins loosened and had to be removed


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 9 - 12
1 Jan 1997
Chehade MJ Pohl AP Pearcy MJ Nawana N

In the assessment of fracture healing by monitoring stiffness with vibrational analysis or instrumented external fixators, it has been assumed that there is a workable correlation between stiffness and strength. We used four-point bending tests to study time-related changes in stiffness and strength in healing tibial fractures in sheep. We aimed to test the validity of the measurement of stiffness to assess fracture strength. At each duration of healing examined, we found marked variations in stiffness and strength. Stiffness was shown to be load-dependent: measurements at higher loads reflected ultimate strength more accurately. There was a biphasic relationship between stiffness and strength: at first there was a strong correlation regardless of loading conditions, but in the second phase, which included the period of ‘clinical healing’, stiffness and strength were not significantly correlated. We conclude that the monitoring of stiffness is useful primarily in assessing progress towards union but is inherently limited as an assessment of strength at the time of clinical union. Any interpretation of stiffness must take into account the load conditions


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 261 - 264
1 Mar 2003
Hosalkar HS Jones S Chowdhury M Hartley J Hill RA

We review the results of a modified quadricepsplasty in five children who developed stiffness of the knee after femoral lengthening for congenital short femur using an Ilizarov external fixator which spanned the knee. All had a full range of movement of the knee before lengthening was undertaken. Unifocal lengthening was carried out in the distal metaphysiodiaphyseal region of the distal femur with a mean gain of 6.5 cm. The mean percentage lengthening was 24%. At the end of one year after removal of the Ilizarov frame and despite intensive physiotherapy all patients had stiffness. Physiotherapy was continued after the quadricepsplasty and, at the latest follow-up (mean 27 months), the mean active flexion was 102° (80 to 130). The gain in movement ranged from 50° to 100°. One patient had a superficial wound infection which settled after a course of oral antibiotics. None developed an increased extension lag after surgery and all were very satisfied with the results. Quadricepsplasty is a useful procedure for stiffness of the knee after femoral lengthening which has not responded to physiotherapy


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 706 - 709
1 Sep 1996
Rowley DI

Over 200 high-velocity missile injuries treated in a low-technology environment were audited under the aegis of the International Committee of the Red Cross Hospitals in Afghanistan and Northern Kenya. Femoral fractures were treated either by traction or external fixation using a uniaxial frame. The results showed that patients treated by external fixation remained in hospital longer than those treated on traction. The positional outcome was identical in both groups. In tibial fractures the external fixator was only of extra benefit in those of the lower third when compared with simple plaster slabs unless more complex procedures such as flaps or vascular repair were to be performed. In complex humeral fractures, external fixation resulted in long stays in hospital and a large number of interventions when compared with simple treatment in a sling. We conclude therefore that in an environment where facilities are limited and surgeons have only general experience very careful initial wound excision is the most important factor determining outcome. The application of complex holding techniques was generally inappropriate


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 24 - 29
1 Jan 1989
Masada K Tsuyuguchi Y Kawai H Kawabata H Noguchi K Ono K

We reviewed 36 cases of forearm deformity caused by multiple osteochondromas in 30 patients and classified them into three types: Type I showed a combination of ulnar shortening and bowing of the radius secondary to osteochondromas of the distal ulna (22 forearms). Type II showed dislocation of the radial head, either with osteochondromas of the proximal radius (Type IIa, two forearms) or secondary to more distal involvement (Type IIb, five forearms). Type III had relative radial shortening due to osteochrondromas at the distal radius (seven forearms). Operations were performed on 16 forearms in 13 patients, with 92% of satisfactory results. For Type I deformity, excision of osteochondromas, immediate ulnar lengthening and corrective osteotomy of the radius are recommended. For Type IIa, excision of the radial head is necessary, and for Type IIb, we advise gradual lengthening of the ulna using an external fixator. Excision of osteochondromas alone gave good results in Type III deformity. Our classification gives a reliable indication of the prognosis and is a guide to the choice of surgical treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 1 | Pages 47 - 52
1 Jan 1985
Knutson K Lindstrand A Lidgren L

Twenty consecutive patients treated by arthrodesis for failed knee arthroplasty are reviewed. Eight hinged, five stabilised and seven compartmental prostheses were removed, for infection (15 cases), loosening (4) and instability (1). One patient refused a second-stage operation but the remainder gained sound fusion. Infected knees had a two-stage procedure with temporary insertion of gentamicin-loaded beads after removal of the prosthesis; all infections healed. Six arthrodeses using a Hoffmann-Vidal external fixator resulted in two temporary failures. One Ace-Fischer external fixation was successful. Of 10 primary attempts at arthrodesis with an intramedullary Kuntscher nail, nine were successful; the tenth fused after two more attempts by the same method. The two failures of external fixation and two failures after Charnley single-frame compression done elsewhere were successfully fused with intramedullary nails. Delayed union in three cases fused after prolonged fixation and repeated bone grafts. The indications for and methods of arthrodesis after failed knee arthroplasty are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 133 - 136
1 Jan 1996
Finsen V Russwurm H

In nine patients of median age 34 years who had sustained an amputation of the thumb at a median 24 (5 to 131) months previously, we lengthened the first metacarpal by 30 (17 to 36) mm. Seven amputations had been through the proximal phalanx and two through the metacarpal. The first two patients had autogenous grafting at a second stage, but the other seven had callotasis alone. In these patients the external fixators were removed at a median 189 (115 to 271) days after osteotomy. In six cases the adductor pollicis tendon was transferred proximally and the first web deepened. There was late fracture or palmar flexion of the callus in five patients, but this required further surgery in only one. Treatment was complete at 326 (140 to 489) days after osteotomy. The extended thumb retained its sensitivity; both grasp and key-pinch strength were satisfactory and only one patient felt that the result did not warrant the long course of treatment. Metacarpal lengthening by this method is a prolonged procedure, but provides a valuable alternative to more complex reconstructions


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 125 - 129
1 Jan 1999
Tsubota S Tsuchiya H Shinokawa Y Tomita K Minato H

We carried out limb lengthening in rabbits and then transplanted osteoblast-like cells derived from the tibial periosteum to the centres of distracted callus immediately after distraction had been terminated. Two weeks later the transaxial area ratio at the centre of the distracted callus and the bone mineral density (BMD) were significantly higher in the transplanted group, by 21% and 42%, respectively, than in the non-injected group or the group injected with physiological saline (p < 0.05). Callus BMD as a percentage of density in uninvolved bone was also significantly higher in the transplanted group (p < 0.05) than in the other two groups, by 27% and 20% in the second and fourth weeks, respectively (p < 0.05). Mechanically, the callus in the transplanted group tended to be stronger as shown by the three-point bending test although the difference in fracture strength was not statistically significant. Our results show that transplantation of osteoblast-like cells promotes maturity of the distracted callus as observed at the second and fourth weeks after lengthening. The method appears promising as a means of shortening the consolidation period of callus distraction and decreasing complications during limb lengthening with an external fixator


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1069 - 1074
1 Sep 2001
Little DG Cornell MS Briody J Cowell CT Arbuckle S Cooke-Yarborough CM

We examined the effect on bone mineral density (BMD) of a single dose of 3 mg/kg of the bisphosphonate, pamidronate (Novartis) in distraction osteogenesis in immature rabbits. Seventeen rabbits (9 control, 8 given pamidronate) were examined by dual-energy x-ray absorptiometry. There was a significant increase in the BMD in the pamidronate group compared with the control animals. The mean areal BMD (g/cm. 2. ) in the bone proximal and distal to the regenerate was increased by 40% and 39%, respectively, compared with the control group (p < 0.05). The BMD of the regenerate bone was increased by a mean of 43% (p < 0.05). There was an increase of 22% in the mean area of regenerate formed in the pamidronate group (p< 0.05). Histological examination of bone in nine rabbits (5 control, 4 pamidronate) showed an increase in osteoblastic rimming and mineralisation of the regenerate, increased formation of bone around the pin sites and an increase in the cortical width of the bone adjacent to the regenerate in the rabbits given pamidronate. Pamidronate had a markedly positive effect. It reduced the disuse osteoporosis normally associated with lengthening using an external fixator and increased the amount and density of the regenerate bone. Further study is required to examine the mechanical properties of the regenerate after the administration of pamidronate


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 543 - 549
1 Aug 1988
Kojimoto H Yasui N Goto T Matsuda S Shimomura Y

The histology and mechanics of leg lengthening by callus distraction were studied in 27 growing rabbits. Tibial diaphyses were subjected to subperiosteal osteotomy, held in a neutral position for 10 days and then slowly distracted at 0.25 mm/12 hours, using a dynamic external fixator. Radiographs showed that the gap became filled with callus having three distinct zones. Elongation appeared to occur in a central radiolucent zone; this was bounded by two sclerotic zones. Histologically, the radiolucent zone consisted of longitudinally arranged cartilage and fibrous tissue while the sclerotic zones were formed by fine cancellous bone. New bone occasionally contained islands of cartilage, suggesting it had been formed by endochondral ossification. After completion of distraction, the two sclerotic zones fused, shrank and were eventually absorbed, leaving tubular bone with a new cortex. When the periosteum had been removed at the operation, callus formation was markedly disturbed and there was failure of bone lengthening. Scraping of endosteum, in contrast, did not have a pronounced effect. These results suggest that the preservation of periosteum is essential if bone lengthening by callus distraction is to succeed, and that preservation of the periosteum is more important than careful corticotomy


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 837 - 843
1 Sep 1994
Apte S Kenwright J

We studied the cellular response to physeal distraction in the growth plates of skeletally immature rabbits. We used a new method of labelling and detection of proliferating cells with bromodeoxyuridine (BUdR) and an anti-BUdR antibody. The application of an external fixator but no distraction force produced no changes in the growth plates. After five days of distraction at a maximum force of 20 N, the growth plate became thicker, mainly because of an increase in the number of hypertrophic chondrocytes, but there was no evidence of increased cell proliferation. Recent fractures were seen at the junction of growth plate and metaphysis but the increase in bone length was insignificant. After ten days of distraction at the same maximum force, the chondrocyte columns had become disorganised and cell proliferation was significantly decreased. There was an increase in bone length due to distraction of the fracture gap. In this model, physeal distraction did not stimulate cell proliferation, but actually inhibited it. The apparent increase in growth-plate thickness produced by distraction is not due to increased cell production, but results from inhibition of endochondral ossification and the consequent accumulation of hypertrophic chondrocytes. Any growth after distraction depends on the ability of growth-plate chondrocytes to divide. The decrease in proliferative activity which we found after ten days of distraction suggests the need for caution in the use of such procedures in young children