Advertisement for orthosearch.org.uk
Results 1 - 100 of 863
Results per page:

Aims. The aim of this study was to assess the reproducibility and validity of cross table radiographs for measuring the anteversion of the acetabular component after total hip arthroplasty (THA) and to compare it with measurements using CT scans. Patients and Methods. A total of 29 patients who underwent THA between June 2010 and January 2016 were included. There were 17 men and 12 women. Their mean age was 43 years (26 to 65). Seven patients underwent a bilateral procedure. Thus, 36 THAs were included in the study. Lateral radiographs and CT scans were obtained post-operatively and radiographs repeated three weeks later. The anteversion of the acetabular component was measured using the method described by Woo and Morrey and the ischiolateral method described by Pulos et al and these were compared with the results obtained from CT scans. Results. The mean anteversion was 18.35° (3° to 38°) using Woo and Morrey’s method, 51.45° (30° to 85°) using the ischiolateral method and 21.22° (2° to 48°) using CT scans. The Pearson correlation coefficient was 0.754 for Woo and Morrey’s method and 0.925 for the ischiolateral method. There was a linear correlation between the measurements using the ischiolateral method and those using CT scans. We derived a simple linear equation between the value of the CT scan and that of ischiolateral method to deduce the CT scan value from that of ischiolateral method and vice versa. . Conclusion. The anteversion of the acetabular component measured using both plain radiographic methods was consistently valid with good interobserver reproducibility, but the ischiolateral method which is independent of pelvic tilt was more accurate. As CT is costly, associated with a high dose of radiation and not readily available, the ischiolateral method can be used for assessing the anteversion of the acetabular component. Cite this article: Bone Joint J 2017;99-B:1006–11


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1200 - 1209
14 Sep 2020
Miyamura S Lans J He JJ Murase T Jupiter JB Chen NC

Aims. We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. Methods. We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves. Results. In the nonunion group, both the distal (100.2%) and proximal (126.6%) fragments had a significantly higher bone density compared to the union (distal: 85.7%; proximal: 108.3%) or control groups (distal: 91.6%; proximal: 109.1%) using the 3D bone density measurement, which were statistically significant for all comparisons. 2D measurements were highly correlated to 3D bone density measurements (Spearman’s correlation coefficient (R) = 0.85 to 0.95). Using 2D measurements, ROC curve analysis revealed the optimal cutoffs of 90.8% and 116.3% for distal and proximal fragments. This led to a sensitivity of 1.00 if either cutoff is met and a specificity of 0.82 when both cutoffs are met. Conclusion. Using 3D modelling software, nonunions were found to exhibit bone density increases in both the distal and proximal fragments in CTs performed between four to 18 weeks after fracture during the course of treatment. 2D bone density measurements using standard CT scans correlate well with 3D models. In patients with scaphoid fractures, CT bone density measurements may be useful in predicting the likelihood of nonunion. Cite this article: Bone Joint J 2020;102-B(9):1200–1209


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 178 - 183
1 Jan 2021
Kubik JF Rollick NC Bear J Diamond O Nguyen JT Kleeblad LJ Wellman DS Helfet DL

Aims. Malreduction of the syndesmosis has been reported in up to 52% of patients after fixation of ankle fractures. Multiple radiological parameters are used to define malreduction; there has been limited investigation of the accuracy of these measurements in differentiating malreduction from inherent anatomical asymmetry. The purpose of this study was to identify the prevalence of positive malreduction standards within the syndesmosis of native, uninjured ankles. Methods. Three observers reviewed 213 bilateral lower limb CT scans of uninjured ankles. Multiple measurements were recorded on the axial CT 1 cm above the plafond: anterior syndesmotic distance; posterior syndesmotic distance; central syndesmotic distance; fibular rotation; and sagittal fibular translation. Previously studied malreduction standards were evaluated on bilateral CT, including differences in: anterior, central and posterior syndesmotic distance; mean syndesmotic distance; fibular rotation; sagittal translational distance; and syndesmotic area. Unilateral CT was used to compare the anterior to posterior syndesmotic distances. Results. A difference of anterior to posterior syndesmotic distance > 2 mm was observed in 89% of ankles (n = 190) on unilateral CT assessment. Using bilateral CT, we found that 35% (n = 75) of normal ankles would be considered malreduced by current malreduction parameters. In 50 patients (23%), only one parameter was anomalous, 18 patients (8%) had two positive parameters and seven patients (3%) had three. Difference in fibular rotation had the lowest false positive rate of all parameters at 6%, whereas posterior syndesmotic distance difference had the highest at 15%. Conclusion. In this study, 35% of native, uninjured syndesmoses (n = 75) would be classified as malreduced by current diagnostic standards on bilateral CT and 89% had an asymmetric incisura on unilateral CT (n = 190). Current radiological parameters are insufficient to differentiate mild inherent anatomical asymmetry from malreduction of the syndesmosis. Cite this article: Bone Joint J 2021;103-B(1):178–183


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1097 - 1100
1 Aug 2012
Venkatesan M Fong A Sell PJ

The aim of this study was first, to determine whether CT scans undertaken to identify serious injury to the viscera were of use in detecting clinically unrecognised fractures of the thoracolumbar vertebrae, and second, to identify patients at risk of ‘missed injury’. . We retrospectively analysed CT scans of the chest and abdomen performed for blunt injury to the torso in 303 patients. These proved to be positive for thoracic and intra-abdominal injuries in only 2% and 1.3% of cases, respectively. However, 51 (16.8%) showed a fracture of the thoracolumbar vertebrae and these constituted our subset for study. There were eight women and 43 men with mean age of 45.2 years (15 to 94). There were 29 (57%) stable and 22 (43%) unstable fractures. Only 17 fractures (33.3%) had been anticipated after clinical examination. Of the 22 unstable fractures, 11 (50%) were anticipated. Thus, within the whole group of 303 patients, an unstable spinal injury was missed in 11 patients (3.6%); no harm resulted as they were all protected until the spine had been cleared. A subset analysis revealed that patients with a high Injury Severity Score, a low Glasgow Coma Scale and haemodynamic instability were most likely to have a significant fracture in the absence of positive clinical findings. This is the group at greatest risk. Clinical examination alone cannot detect significant fractures of the thoracolumbar spine. It should be combined with CT imaging to reduce the risk of missed injury


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 239 - 243
1 Mar 2004
Cutler L Molloy A Dhukuram V Bass A

Distal tibial physeal fractures are the second most common growth plate injury and the most common cause of growth arrest and deformity. This study assesses the accuracy of pre-operative planning for placement of the screws in these fractures using either standard radiographs or CT scans. We studied 62 consecutive physeal fractures over a period of four years. An outline of a single cut of the CT scan was used for each patient. An ideal position for the screw was determined as being perpendicular to and at the midpoint of the fracture. The difference in entry point and direction of the screw between the ideal and the observers’ assessments were compared using the paired Student’s t-test. There was a statistically significant improvement (p < 0.0001) in the accuracy of the point of insertion and the direction of the screw on the pre-operative plan when CT scans were used rather than plain radiographs. We would, therefore, recommend that CT scans are routinely used in the pre-operative assessment and treatment of distal tibial physeal fractures


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1668 - 1673
1 Dec 2016
Konda SR Goch AM Leucht P Christiano A Gyftopoulos S Yoeli G Egol KA

Aims. To evaluate whether an ultra-low-dose CT protocol can diagnose selected limb fractures as well as conventional CT (C-CT). Patients and Methods. We prospectively studied 40 consecutive patients with a limb fracture in whom a CT scan was indicated. These were scanned using an ultra-low-dose CT Reduced Effective Dose Using Computed Tomography In Orthopaedic Injury (REDUCTION) protocol. Studies from 16 selected cases were compared with 16 C-CT scans matched for age, gender and type of fracture. Studies were assessed for diagnosis and image quality. Descriptive and reliability statistics were calculated. The total effective radiation dose for each scanned site was compared. Results. The mean estimated effective dose (ED) for the REDUCTION protocol was 0.03 milliSieverts (mSv) and 0.43 mSv (p < 0.005) for C-CT. The sensitivity (Sn), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) of the REDUCTION protocol to detect fractures were 0.98, 0.89, 0.98 and 0.89 respectively when two occult fractures were excluded. Inter- and intra-observer reliability for diagnosis using the REDUCTION protocol (κ = 0.75, κ = 0.71) were similar to those of C-CT (κ = 0.85, κ = 0.82). Using the REDUCTION protocol, 3D CT reconstructions were equivalent in quality and diagnostic information to those generated by C-CT (κ = 0.87, κ = 0.94). Conclusion. With a near 14-fold reduction in estimated ED compared with C-CT, the REDUCTION protocol reduces the amount of CT radiation substantially without significant diagnostic decay. It produces images that appear to be comparable with those of C-CT for evaluating fractures of the limbs. Cite this article: Bone Joint J 2016;98-B:1668-73


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 379 - 382
1 May 1990
Egund N Nilsson L Wingstrand H Stromqvist B Pettersson H

Computed tomography was performed on 40 patients with recent hip trauma. Radiographs of 25 showed a fracture of the femoral neck with slight displacement; 24 of these had intra-articular fluid and 20 had a lipohaemarthrosis on the CT scan. In 15 patients, radiographs at the time of admission were normal but suspicion of fracture remained. A fracture was later verified in five patients, four of whom had lipohaemarthrosis on admission. In the remaining 10 patients no fracture could be detected; only one patient had a hip joint effusion but no free fat. Thus all 24 patients with lipohaemarthrosis had an intracapsular fracture of the hip. We suggest CT for patients with hip trauma and negative radiographs. The presence of a lipohaemarthrosis of the hip strongly suggests an intra-articular fracture of either the femoral neck or the acetabulum


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 381 - 384
1 May 1991
Cohen M Wall E Kerber C Abitbol J Garfin

The nerve roots of the cauda equina may be visualised by contrast-enhanced CT scans and by surface-coil MRI. We have identified the pattern of anatomy from L2-L3 to L5-S1 in 10 human cadaver specimens and correlated this with anatomical dissections. Individual roots are slightly more distinct on contrast-enhanced CT than on surface-coil MRI. There is a crescentic oblique pattern of nerve roots at the lower lumbar levels which is still apparent in the more crowded proximal sections. In all cases, the axial images correlated precisely with the dissections. Current imaging modalities can help the clinical understanding and management of abnormalities in this region of the spine


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 390 - 392
1 May 1989
Hamabuchi M Hasegawa R Murase T

Teratomas in the spinal cord are rare. We report a case in a 54-year-old man. CT scans revealed tumours of different densities within the spinal canal; this heterogeneity may help to differentiate teratoma from other spinal cord tumours. After resection of the tumours under microscopy, the result was excellent. Histological examination showed a variety of tissues, including elements of all three germinal layers


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 480 - 485
1 May 1990
Antti-Poika I Soini J Tallroth K Yrjonen T Konttinen Y

Two different classifications of discograms have been used in a prospective study of 279 injected discs in 100 patients. The five-stage classification of Adams, Dolan and Hutton (1986) showed increased degeneration in the lower lumbar discs and more degenerative changes in men than in women. Exact reproduction of the patient's pain on injection was more common in fissured or ruptured discs than in less degenerate discs, with 81% sensitivity and 64% specificity of the discogram for pain. The additional information obtained by comparing computerised tomography (CT) with discograms was minimal. Discography was found to be useful in the evaluation of chronic low back pain in patients whose ordinary CT scans, myelograms and flexion-extension radiographs were normal. In spondylolysis and spondylolisthesis, discography can disclose whether fusion needs to be extended above the lytic level, and it may show if the pain in patients who have had posterolateral fusion is discogenic. Thus, discography gives information which is useful in deciding whether to operate on patients with chronic low back pain


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 208 - 212
1 Mar 1986
Macdonald W Thrum C Hamilton S

Techniques are described by which metal implants can be designed and produced to fit precisely a bony site at a subsequent operation. CT scans and solid modelling were used to produce an accurate three-dimensional representation of the surface of the bone. These techniques were applied to the production of an internal fixation device for shoulder arthrodesis after the resection of a neoplasm of the proximal humerus. The reconstruction utilised a free vascularised fibular graft between the scapula and the distal humeral remnant, fixation being secured with the custom-made implant


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1395 - 1399
1 Oct 2011
Lee D Kim NH Park J Hwang CJ Lee CS Kim Y Kang SJ Rhee JM

We performed a prospective study to examine the influence of the patient’s position on the location of the abdominal organs, to investigate the possibility of a true lateral approach for transforaminal endoscopic lumbar discectomy. Pre-operative abdominal CT scans were taken in 20 patients who underwent endoscopic lumbar discectomy. Axial images in parallel planes of each intervertebral disc from L1 to L5 were achieved in both supine and prone positions. The most horizontal approach angles possible to avoid injury to the abdominal organs were measured. The results demonstrated that the safe approach angles were significantly less (i.e., more horizontal) in the prone than in the supine position. Obstacles to a more lateral approach were mainly the liver, the spleen and the kidneys at L1/2 (39 of 40, 97.5%) and L2/3 (28 of 40, 70.0%), and the intestines at L3/4 (33 of 40, 82.5%) and L4/5 (30 of 30, 100%). A true lateral approach from each side was possible for 30 of the 40 discs at L3/4 (75%) and 23 of the 30 discs at L4/5 (76.7%). We concluded that a more horizontal approach for transforaminal endoscopic lumbar discectomy is possible in the prone position but not in the supine. Prone abdominal CT is more helpful in determining the trajectory of the endoscope. While a true lateral approach is feasible in many patients, our study shows it is not universally applicable.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 683 - 685
1 Sep 1992
Fontijne W de Klerk L Braakman R Stijnen T Tanghe H Steenbeek R van Linge B

In 139 patients with burst fractures of the thoracic, thoracolumbar or lumbar spine, the least sagittal diameter of the spinal canal at the level of injury was measured by computerised tomography. By multiple logistic regression we investigated the joint correlation of the level of the burst fracture and the percentage of spinal canal stenosis with the probability of an associated neurological deficit. There was a very significant correlation between neurological deficit and the percentage of spinal canal stenosis; the higher the level of injury the greater was the probability. The severity of neurological deficit could not be predicted.


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1133 - 1140
1 Oct 2024
Olsen Kipp J Petersen ET Falstie-Jensen T Frost Teilmann J Zejden A Jellesen Åberg R de Raedt S Thillemann TM Stilling M

Aims. This study aimed to quantify the shoulder kinematics during an apprehension-relocation test in patients with anterior shoulder instability (ASI) and glenoid bone loss using the radiostereometric analysis (RSA) method. Kinematics were compared with the patient’s contralateral healthy shoulder. Methods. A total of 20 patients with ASI and > 10% glenoid bone loss and a healthy contralateral shoulder were included. RSA imaging of the patient’s shoulders was performed during a repeated apprehension-relocation test. Bone volume models were generated from CT scans, marked with anatomical coordinate systems, and aligned with the digitally reconstructed bone projections on the RSA images. The glenohumeral joint (GHJ) kinematics were evaluated in the anteroposterior and superoinferior direction of: the humeral head centre location relative to the glenoid centre; and the humeral head contact point location on the glenoid. Results. During the apprehension test, the centre of the humeral head was 1.0 mm (95% CI 0.0 to 2.0) more inferior on the glenoid for the ASI shoulder compared with the healthy shoulder. Furthermore, the contact point of the ASI shoulder was 1.4 mm (95% CI 0.3 to 2.5) more anterior and 2.0 mm (95% CI 0.8 to 3.1) more inferior on the glenoid compared with the healthy shoulder. The contact point of the ASI shoulder was 1.2 mm (95% CI 0.2 to 2.6) more anterior during the apprehension test compared to the relocation test. Conclusion. The humeral head centre was located more inferior, and the GHJ contact point was located both more anterior and inferior during the apprehension test for the ASI shoulders than the healthy shoulders. Furthermore, the contact point displacement between the apprehension and relocation test revealed increased joint laxity for the ASI shoulder than the healthy shoulders. These results contribute to existing knowledge that ASI shoulders with glenoid bone loss may also suffer from inferior shoulder instability. Cite this article: Bone Joint J 2024;106-B(10):1133–1140


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 475 - 481
1 May 2024
Lee M Lee G Lee K

Aims. The purpose of this study was to assess the success rate and functional outcomes of bone grafting for periprosthetic bone cysts following total ankle arthroplasty (TAA). Additionally, we evaluated the rate of graft incorporation and identified associated predisposing factors using CT scan. Methods. We reviewed a total of 37 ankles (34 patients) that had undergone bone grafting for periprosthetic bone cysts. A CT scan was performed one year after bone grafting to check the status of graft incorporation. For accurate analysis of cyst volumes and their postoperative changes, 3D-reconstructed CT scan processed with 3D software was used. For functional outcomes, variables such as the Ankle Osteoarthritis Scale score and the visual analogue scale for pain were measured. Results. Out of 37 ankles, graft incorporation was successful in 30 cases. Among the remaining seven cases, four (10.8%) exhibited cyst re-progression, so secondary bone grafting was needed. After secondary bone grafting, no further progression has been noted, resulting in an overall 91.9% success rate (34 of 37) at a mean follow-up period of 47.5 months (24 to 120). The remaining three cases (8.1%) showed implant loosening, so tibiotalocalcaneal arthrodesis was performed. Functional outcomes were also improved after bone grafting in all variables at the latest follow-up (p < 0.05). The mean incorporation rate of the grafts according to the location of the cysts was 84.8% (55.2% to 96.1%) at the medial malleolus, 65.1% (27.6% to 97.1%) at the tibia, and 81.2% (42.8% to 98.7%) at the talus. Smoking was identified as a significant predisposing factor adversely affecting graft incorporation (p = 0.001). Conclusion. Bone grafting for periprosthetic bone cysts following primary TAA is a reliable procedure with a satisfactory success rate and functional outcomes. Regular follow-up, including CT scan, is important for the detection of cyst re-progression to prevent implant loosening after bone grafting. Cite this article: Bone Joint J 2024;106-B(5):475–481


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 97 - 103
1 Mar 2024
Baujard A Martinot P Demondion X Dartus J Faure PA Girard J Migaud H

Aims. Mechanical impingement of the iliopsoas (IP) tendon accounts for 2% to 6% of persistent postoperative pain after total hip arthroplasty (THA). The most common initiator is anterior acetabular component protrusion, where the anterior margin is not covered by anterior acetabular wall. A CT scan can be used to identify and measure this overhang; however, no threshold exists for determining symptomatic anterior IP impingement due to overhang. A case-control study was conducted in which CT scan measurements were used to define a threshold that differentiates patients with IP impingement from asymptomatic patients after THA. Methods. We analyzed the CT scans of 622 patients (758 THAs) between May 2011 and May 2020. From this population, we identified 136 patients with symptoms suggestive of IP impingement. Among them, six were subsequently excluded: three because the diagnosis was refuted intraoperatively, and three because they had another obvious cause of impingement, leaving 130 hips (130 patients) in the study (impingement) group. They were matched to a control group of 138 asymptomatic hips (138 patients) after THA. The anterior acetabular component overhang was measured on an axial CT slice based on anatomical landmarks (orthogonal to the pelvic axis). Results. The impingement group had a median overhang of 8 mm (interquartile range (IQR) 5 to 11) versus 0 mm (IQR 0 to 4) for the control group (p < 0.001). Using receiver operating characteristic curves, an overhang threshold of 4 mm was best correlated with a diagnosis of impingement (sensitivity 79%, specificity 85%; positive predictive value 75%, negative predictive value 85%). Conclusion. Pain after THA related to IP impingement can be reasonably linked to acetabular overhang if it exceeds 4 mm on a CT scan. Below this threshold, it seems logical to look for another cause of IP irritation or another reason for the pain after THA before concluding that impingement is present. Cite this article: Bone Joint J 2024;106-B(3 Supple A):97–103


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 359 - 364
1 Apr 2024
Özdemir E de Lange B Buckens CFM Rijnen WHC Visser J

Aims. To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time. Methods. We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated. Results. The mean time between the implantation and the second CT scan was two years (1 to 5). The mean age of the patients during CTAC implantation was 75 years (60 to 92). The mean scaffold-bone contact area increased from 16% (SD 12.6) to 28% (SD 11.9). The mean scaffold-bone distance decreased from a mean of 6.5 mm (SD 2.0) to 5.5 mm (SD 1.6). None of the CTACs were revised or radiologically loose. Conclusion. There was a statistically significant increase of scaffold-bone contact area over time, but the total contact area of the scaffold in relation to the acetabular bone remained relatively low. As all implants remained well fixed, the question remains to what extend the scaffold contributes to the observed stability, in relation to the screws. A future design implication might be an elimination of the bulky scaffold component. This design modification would reduce production costs and may optimize the primary fit of the implant. Cite this article: Bone Joint J 2024;106-B(4):359–364


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1041 - 1047
1 Aug 2020
Hamoodi Z Singh J Elvey MH Watts AC

Aims. The Wrightington classification system of fracture-dislocations of the elbow divides these injuries into six subtypes depending on the involvement of the coronoid and the radial head. The aim of this study was to assess the reliability and reproducibility of this classification system. Methods. This was a blinded study using radiographs and CT scans of 48 consecutive patients managed according to the Wrightington classification system between 2010 and 2018. Four trauma and orthopaedic consultants, two post CCT fellows, and one speciality registrar based in the UK classified the injuries. The seven observers reviewed preoperative radiographs and CT scans twice, with a minimum four-week interval. Radiographs and CT scans were reviewed separately. Inter- and intraobserver reliability were calculated using Fleiss and Cohen kappa coefficients. The Landis and Koch criteria were used to interpret the strength of the kappa values. Validity was assessed by calculating the percentage agreement against intraoperative findings. Results. Of the 48 patients, three (6%) had type A injury, 11 (23%) type B, 16 (33%) type B+, 16 (33%) Type C, two (4%) type D+, and none had a type D injury. All 48 patients had anteroposterior (AP) and lateral radiographs, 44 had 2D CT scans, and 39 had 3D reconstructions. The interobserver reliability kappa value was 0.52 for radiographs, 0.71 for 2D CT scans, and 0.73 for a combination of 2D and 3D reconstruction CT scans. The median intraobserver reliability was 0.75 (interquartile range (IQR) 0.62 to 0.79) for radiographs, 0.77 (IQR 0.73 to 0.94) for 2D CT scans, and 0.89 (IQR 0.77 to 0.93) for the combination of 2D and 3D reconstruction. Validity analysis showed that accuracy significantly improved when using CT scans (p = 0.018 and p = 0.028 respectively). Conclusion. The Wrightington classification system is a reliable and valid method of classifying fracture-dislocations of the elbow. CT scans are significantly more accurate than radiographs when identifying the pattern of injury, with good intra- and interobserver reproducibility. Cite this article: Bone Joint J 2020;102-B(8):1041–1047


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 971 - 975
1 May 2021
Hurley P Azzopardi C Botchu R Grainger M Gardner A

Aims. The aim of this study was to assess the reliability of using MRI scans to calculate the Spinal Instability Neoplastic Score (SINS) in patients with metastatic spinal cord compression (MSCC). Methods. A total of 100 patients were retrospectively included in the study. The SINS score was calculated from each patient’s MRI and CT scans by two consultant musculoskeletal radiologists (reviewers 1 and 2) and one consultant spinal surgeon (reviewer 3). In order to avoid potential bias in the assessment, MRI scans were reviewed first. Bland-Altman analysis was used to identify the limits of agreement between the SINS scores from the MRI and CT scans for the three reviewers. Results. The limit of agreement between the SINS score from the MRI and CT scans for the reviewers was -0.11 for reviewer 1 (95% CI 0.82 to -1.04), -0.12 for reviewer 2 (95% CI 1.24 to -1.48), and -0.37 for reviewer 3 (95% CI 2.35 to -3.09). The use of MRI tended to increase the score when compared with that using the CT scan. No patient having their score calculated from MRI scans would have been classified as stable rather than intermediate or unstable when calculated from CT scans, potentially leading to suboptimal care. Conclusion. We found that MRI scans can be used to calculate the SINS score reliably, compared with the score from CT scans. The main difference between the scores derived from MRI and CT was in defining the type of bony lesion. This could be made easier by knowing the site of the primary tumour when calculating the score, or by using inverted T1-volumetric interpolated breath-hold examination MRI to assess the bone more reliably, similar to using CT. Cite this article: Bone Joint J 2021;103-B(5):971–975


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 59 - 65
1 Jul 2021
Bracey DN Hegde V Shimmin AJ Jennings JM Pierrepont JW Dennis DA

Aims. Cross-table lateral (CTL) radiographs are commonly used to measure acetabular component anteversion after total hip arthroplasty (THA). The CTL measurements may differ by > 10° from CT scan measurements but the reasons for this discrepancy are poorly understood. Anteversion measurements from CTL radiographs and CT scans are compared to identify spinopelvic parameters predictive of inaccuracy. Methods. THA patients (n = 47; 27 males, 20 females; mean age 62.9 years (SD 6.95)) with preoperative spinopelvic mobility, radiological analysis, and postoperative CT scans were retrospectively reviewed. Acetabular component anteversion was measured on postoperative CTL radiographs and CT scans using 3D reconstructions of the pelvis. Two cohorts were identified based on a CTL-CT error of ≥ 10° (n = 11) or < 10° (n = 36). Spinopelvic mobility parameters were compared using independent-samples t-tests. Correlation between error and mobility parameters were assessed with Pearson’s coefficient. Results. Patients with CTL error > 10° (10° to 14°) had stiffer lumbar spines with less mean lumbar flexion (38.9°(SD 11.6°) vs 47.4° (SD 13.1°); p = 0.030), different sagittal balance measured by pelvic incidence-lumbar lordosis mismatch (5.9° (SD 18.8°) vs -1.7° (SD 9.8°); p = 0.042), more pelvic extension when seated (pelvic tilt -9.7° (SD 14.1°) vs -2.2° (SD 13.2°); p = 0.050), and greater change in pelvic tilt between supine and seated positions (12.6° (SD 12.1°) vs 4.7° (SD 12.5°); p = 0.036). The CTL measurement error showed a positive correlation with increased CTL anteversion (r = 0.5; p = 0.001), standing lordosis (r = 0.23; p = 0.050), seated lordosis (r = 0.4; p = 0.009), and pelvic tilt change between supine and step-up positions (r = 0.34; p = 0.010). Conclusion. Differences in spinopelvic mobility may explain the variability of acetabular anteversion measurements made on CTL radiographs. Patients with stiff spines and increased compensatory pelvic movement have less accurate measurements on CTL radiographs. Flexion of the contralateral hip is required to obtain clear CTL radiographs. In patients with lumbar stiffness, this movement may extend the pelvis and increase anteversion of the acetabulum on CTL views. Reliable analysis of acetabular component anteversion in this patient population may require advanced imaging with a CT scan. Cite this article: Bone Joint J 2021;103-B(7 Supple B):59–65


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1226 - 1232
1 Nov 2023
Prijs J Rawat J ten Duis K IJpma FFA Doornberg JN Jadav B Jaarsma RL

Aims. Triplane ankle fractures are complex injuries typically occurring in children aged between 12 and 15 years. Classic teaching that closure of the physis dictates the overall fracture pattern, based on studies in the 1960s, has not been challenged. The aim of this paper is to analyze whether these injuries correlate with the advancing closure of the physis with age. Methods. A fracture mapping study was performed in 83 paediatric patients with a triplane ankle fracture treated in three trauma centres between January 2010 and June 2020. Patients aged younger than 18 years who had CT scans available were included. An independent Paediatric Orthopaedic Trauma Surgeon assessed all CT scans and classified the injuries as n-part triplane fractures. Qualitative analysis of the fracture pattern was performed using the modified Cole fracture mapping technique. The maps were assessed for both patterns and correlation with the closing of the physis until consensus was reached by a panel of six surgeons. Results. Fracture map grouped by age demonstrates that, regardless of age (even at the extremes of the spectrum), the fracture lines consolidate in a characteristic Y-pattern, and no shift with closure of the physis was observed. A second fracture map with two years added to female age also did not show a shift. The fracture map, grouped by both age and sex, shows a Y-pattern in all different groups. The fracture lines appear to occur between the anterior and posterior inferior tibiofibular ligaments, and the medially fused physis or deltoid ligament. Conclusion. This fracture mapping study reveals that triplane ankle fractures have a characteristic Y-pattern, and acknowledges the weakness created by the physis, however it also challenges classic teaching that the specific fracture pattern at the level of the joint of these injuries relies on advancing closure of the physis with age. Instead, this study observes the importance of ligament attachment in the fracture patterns of these injuries. Cite this article: Bone Joint J 2023;105-B(11):1226–1232


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1110 - 1117
12 Oct 2022
Wessling M Gebert C Hakenes T Dudda M Hardes J Frieler S Jeys LM Hanusrichter Y

Aims. The aim of this study was to examine the implant accuracy of custom-made partial pelvis replacements (PPRs) in revision total hip arthroplasty (rTHA). Custom-made implants offer an option to achieve a reconstruction in cases with severe acetabular bone loss. By analyzing implant deviation in CT and radiograph imaging and correlating early clinical complications, we aimed to optimize the usage of custom-made implants. Methods. A consecutive series of 45 (2014 to 2019) PPRs for Paprosky III defects at rTHA were analyzed comparing the preoperative planning CT scans used to manufacture the implants with postoperative CT scans and radiographs. The anteversion (AV), inclination (IC), deviation from the preoperatively planned implant position, and deviation of the centre of rotation (COR) were explored. Early postoperative complications were recorded, and factors for malpositioning were sought. The mean follow-up was 30 months (SD 19; 6 to 74), with four patients lost to follow-up. Results. Mean CT defined discrepancy (Δ) between planned and achieved AV and IC was 4.5° (SD 3°; 0° to 12°) and 4° (SD 3.5°; 1° to 12°), respectively. Malpositioning (Δ > 10°) occurred in five hips (10.6%). Native COR reconstruction was planned in 42 cases (93%), and the mean 3D deviation vector was 15.5 mm (SD 8.5; 4 to 35). There was no significant influence in malpositioning found for femoral stem retention, surgical approach, or fixation method. Conclusion. At short-term follow-up, we found that PPR offers a viable solution for rTHA in cases with massive acetabular bone loss, as highly accurate positioning can be accomplished with meticulous planning, achieving anatomical reconstruction. Accuracy of achieved placement contributed to reduced complications with no injury to vital structures by screw fixation. Cite this article: Bone Joint J 2022;104-B(10):1110–1117


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 74 - 81
1 May 2024
Callary SA Broekhuis D Barends J Ramasamy B Nelissen RGHH Solomon LB Kaptein BL

Aims. The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) – the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) – using virtual modelling. Methods. Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients. Computer models of the TMARS reconstruction were segmented from postoperative CT scans using a semi-automated method. The amount of bone removed, the implant-bone apposition that was achieved, and the restoration of the centre of rotation of the hip were compared between all the actual TMARS and the virtual CTAC implants. Results. The median amount of bone removed for TMARS reconstructions was significantly greater than for CTAC implants (9.07 cm. 3. (interquartile range (IQR) 5.86 to 21.42) vs 1.16 cm. 3. (IQR 0.42 to 3.53) (p = 0.004). There was no significant difference between the median overall implant-bone apposition between TMARS reconstructions and CTAC implants (54.8 cm. 2. (IQR 28.2 to 82.3) vs 56.6 cm. 2. (IQR 40.6 to 69.7) (p = 0.683). However, there was significantly more implant-bone apposition within the residual acetabulum (45.2 cm. 2. (IQR 28.2 to 72.4) vs 25.5 cm. 2. (IQR 12.8 to 44.1) (p = 0.001) and conversely significantly less apposition with the outer cortex of the pelvis for TMARS implants compared with CTAC reconstructions (0 cm. 2. (IQR 0 to 13.1) vs 23.2 cm. 2. (IQR 16.4 to 30.6) (p = 0.009). The mean centre of rotation of the hip of TMARS reconstructions differed by a mean of 11.1 mm (3 to 28) compared with CTAC implants. Conclusion. In using TMARS, more bone is removed, thus achieving more implant-bone apposition within the residual acetabular bone. In CTAC implants, the amount of bone removed is minimal, while the implant-bone apposition is more evenly distributed between the residual acetabulum and the outer cortex of the pelvis. The differences suggest that these implants used to treat pelvic discontinuity might achieve short- and long-term stability through different biomechanical mechanisms. Cite this article: Bone Joint J 2024;106-B(5 Supple B):74–81


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1380 - 1385
2 Aug 2021
Kim Y Ryu J Kim JK Al-Dhafer BAA Shin YH

Aims. The aim of this study was to assess arthritis of the basal joint of the thumb quantitatively using bone single-photon emission CT/CT (SPECT/CT) and evaluate its relationship with patients’ pain and function. Methods. We retrospectively reviewed 30 patients (53 hands) with symptomatic basal joint arthritis of the thumb between April 2019 and March 2020. Visual analogue scale (VAS) scores for pain, grip strength, and pinch power of both hands and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores were recorded for all patients. Basal joint arthritis was classified according to the modified Eaton-Glickel stage using routine radiographs and the CT scans of SPECT/CT, respectively. The maximum standardized uptake value (SUVmax) from SPECT/CT was measured in the four peritrapezial joints and the highest uptake was used for analysis. Results. According to Eaton-Glickel classification, 11, 17, 17, and eight hands were stage 0 to I, II, III, and IV, respectively. The interobserver reliability for determining the stage of arthritis was moderate for radiographs (k = 0.41) and substantial for CT scans (k = 0.67). In a binary categorical analysis using SUVmax, pain (p < 0.001) and PRWHE scores (p = 0.004) were significantly higher in hands with higher SUVmax. Using multivariate linear regression to estimate the pain VAS, only SUVmax (B 0.172 (95% confidence interval (CI) 0.065 to 0.279; p = 0.002) showed a significant association. Estimating the variation of PRWHE scores using the same model, only SUVmax (B 1.378 (95% CI, 0.082 to 2.674); p = 0.038) showed a significant association. Conclusion. The CT scans of SPECT/CT provided better interobserver reliability than routine radiographs for evaluating the severity of arthritis. A higher SUVmax in SPECT/CT was associated with more pain and functional disabilities of basal joint arthritis of the thumb. This approach could be used to complement radiographs for the evaluation of patients with this condition. Cite this article: Bone Joint J 2021;103-B(8):1380–1385


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 892 - 897
1 Sep 2024
Mancino F Fontalis A Kayani B Magan A Plastow R Haddad FS

Advanced 3D imaging and CT-based navigation have emerged as valuable tools to use in total knee arthroplasty (TKA), for both preoperative planning and the intraoperative execution of different philosophies of alignment. Preoperative planning using CT-based 3D imaging enables more accurate prediction of the size of components, enhancing surgical workflow and optimizing the precision of the positioning of components. Surgeons can assess alignment, osteophytes, and arthritic changes better. These scans provide improved insights into the patellofemoral joint and facilitate tibial sizing and the evaluation of implant-bone contact area in cementless TKA. Preoperative CT imaging is also required for the development of patient-specific instrumentation cutting guides, aiming to reduce intraoperative blood loss and improve the surgical technique in complex cases. Intraoperative CT-based navigation and haptic guidance facilitates precise execution of the preoperative plan, aiming for optimal positioning of the components and accurate alignment, as determined by the surgeon’s philosophy. It also helps reduce iatrogenic injury to the periarticular soft-tissue structures with subsequent reduction in the local and systemic inflammatory response, enhancing early outcomes. Despite the increased costs and radiation exposure associated with CT-based navigation, these many benefits have facilitated the adoption of imaged based robotic surgery into routine practice. Further research on ultra-low-dose CT scans and exploration of the possible translation of the use of 3D imaging into improved clinical outcomes are required to justify its broader implementation. Cite this article: Bone Joint J 2024;106-B(9):892–897


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 739 - 745
1 Apr 2021
Mehta JS Hodgson K Yiping L Kho JSB Thimmaiah R Topiwala U Sawlani V Botchu R

Aims. To benchmark the radiation dose to patients during the course of treatment for a spinal deformity. Methods. Our radiation dose database identified 25,745 exposures of 6,017 children (under 18 years of age) and adults treated for a spinal deformity between 1 January 2008 and 31 December 2016. Patients were divided into surgical (974 patients) and non-surgical (5,043 patients) cohorts. We documented the number and doses of ionizing radiation imaging events (radiographs, CT scans, or intraoperative fluoroscopy) for each patient. All the doses for plain radiographs, CT scans, and intraoperative fluoroscopy were combined into a single effective dose by a medical physicist (milliSivert (mSv)). Results. There were more ionizing radiation-based imaging events and higher radiation dose exposures in the surgical group than in the non-surgical group (p < 0.001). The difference in effective dose for children between the surgical and non-surgical groups was statistically significant, the surgical group being significantly higher (p < 0.001). This led to a higher estimated risk of cancer induction for the surgical group (1:222 surgical vs 1:1,418 non-surgical). However, the dose difference for adults was not statistically different between the surgical and non-surgical groups. In all cases the effective dose received by all cohorts was significantly higher than that from exposure to natural background radiation. Conclusion. The treatment of spinal deformity is radiation-heavy. The dose exposure is several times higher when surgical treatment is undertaken. Clinicians should be aware of this and review their practices in order to reduce the radiation dose where possible. Cite this article: Bone Joint J 2021;103-B(4):1–7


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1020 - 1029
1 Sep 2023
Trouwborst NM ten Duis K Banierink H Doornberg JN van Helden SH Hermans E van Lieshout EMM Nijveldt R Tromp T Stirler VMA Verhofstad MHJ de Vries JPPM Wijffels MME Reininga IHF IJpma FFA

Aims. The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a total hip arthroplasty (THA), and to determine predictors for conversion to THA in patients treated nonoperatively for acetabular fractures. Methods. A multicentre cross-sectional study was performed in 170 patients who were treated nonoperatively for an acetabular fracture in three level 1 trauma centres. Using the post-injury diagnostic CT scan, the maximum gap and step-off values in the weightbearing dome were digitally measured by two trauma surgeons. Native hip survival was reported using Kaplan-Meier curves. Predictors for conversion to THA were determined using Cox regression analysis. Results. Of 170 patients, 22 (13%) subsequently received a THA. Native hip survival in patients with a step-off ≤ 2 mm, > 2 to 4 mm, or > 4 mm differed at five-year follow-up (respectively: 94% vs 70% vs 74%). Native hip survival in patients with a gap ≤ 2 mm, > 2 to 4 mm, or > 4 mm differed at five-year follow-up (respectively: 100% vs 84% vs 78%). Step-off displacement > 2 mm (> 2 to 4 mm hazard ratio (HR) 4.9, > 4 mm HR 5.6) and age > 60 years (HR 2.9) were independent predictors for conversion to THA at follow-up. Conclusion. Patients with minimally displaced acetabular fractures who opt for nonoperative fracture treatment may be informed that fracture displacement (e.g. gap and step-off) up to 2 mm, as measured on CT images, results in limited risk on conversion to THA. Step-off ≥ 2 mm and age > 60 years are predictors for conversion to THA and can be helpful in the shared decision-making process. Cite this article: Bone Joint J 2023;105-B(9):1020–1029


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 912 - 919
1 Aug 2023
Cunningham LJ Walton M Bale S Trail IA

Aims. Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA). Methods. A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion. Results. RSA analysis showed a small increase in all translation and rotational values up to six months postoperatively, consistent with settling of the implant. The mean values plateaued by 12 months, with no evidence of further migration. In four patients, there was significant variation outside the mean, which corresponded to postoperative complications. There was a significant improvement in the clinical and patient-reported outcomes from the preoperative values to those at two years postoperatively (p < 0.001). Conclusion. These findings show, using RSA, that a glenoid baseplate composite of a trabecular titanium peg with autograft stabilizes within the glenoid about 12 months after surgery, and reinforce findings from a previous study of this implant/graft with CT scans at two years postoperatively, indicating that this type of structural composite results in sound early fixation. Cite this article: Bone Joint J 2023;105-B(8):912–919


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1196 - 1201
1 Nov 2022
Anderson CG Brilliant ZR Jang SJ Sokrab R Mayman DJ Vigdorchik JM Sculco PK Jerabek SA

Aims. Although CT is considered the benchmark to measure femoral version, 3D biplanar radiography (hipEOS) has recently emerged as a possible alternative with reduced exposure to ionizing radiation and shorter examination time. The aim of our study was to evaluate femoral stem version in postoperative total hip arthroplasty (THA) patients and compare the accuracy of hipEOS to CT. We hypothesize that there will be no significant difference in calculated femoral stem version measurements between the two imaging methods. Methods. In this study, 45 patients who underwent THA between February 2016 and February 2020 and had both a postoperative CT and EOS scan were included for evaluation. A fellowship-trained musculoskeletal radiologist and radiological technician measured femoral version for CT and 3D EOS, respectively. Comparison of values for each imaging modality were assessed for statistical significance. Results. Comparison of the mean postoperative femoral stem version measurements between CT and 3D hipEOS showed no significant difference (p = 0.862). In addition, the two version measurements were strongly correlated (r = 0.95; p < 0.001), and the mean paired difference in postoperative femoral version for CT scan and 3D biplanar radiography was -0.09° (95% confidence interval -1.09 to 0.91). Only three stem measurements (6.7%) were considered outliers with a > 5° difference. Conclusion. Our study supports the use of low-dose biplanar radiography for the postoperative assessment of femoral stem version after THA, demonstrating high correlation with CT. We found no significant difference for postoperative femoral version when comparing CT to 3D EOS. We believe 3D EOS is a reliable option to measure postoperative femoral version given its advantages of lower radiation dosage and shorter examination time. Cite this article: Bone Joint J 2022;104-B(11):1196–1201


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1348 - 1360
1 Nov 2024
Spek RWA Smith WJ Sverdlov M Broos S Zhao Y Liao Z Verjans JW Prijs J To M Åberg H Chiri W IJpma FFA Jadav B White J Bain GI Jutte PC van den Bekerom MPJ Jaarsma RL Doornberg JN

Aims. The purpose of this study was to develop a convolutional neural network (CNN) for fracture detection, classification, and identification of greater tuberosity displacement ≥ 1 cm, neck-shaft angle (NSA) ≤ 100°, shaft translation, and articular fracture involvement, on plain radiographs. Methods. The CNN was trained and tested on radiographs sourced from 11 hospitals in Australia and externally validated on radiographs from the Netherlands. Each radiograph was paired with corresponding CT scans to serve as the reference standard based on dual independent evaluation by trained researchers and attending orthopaedic surgeons. Presence of a fracture, classification (non- to minimally displaced; two-part, multipart, and glenohumeral dislocation), and four characteristics were determined on 2D and 3D CT scans and subsequently allocated to each series of radiographs. Fracture characteristics included greater tuberosity displacement ≥ 1 cm, NSA ≤ 100°, shaft translation (0% to < 75%, 75% to 95%, > 95%), and the extent of articular involvement (0% to < 15%, 15% to 35%, or > 35%). Results. For detection and classification, the algorithm was trained on 1,709 radiographs (n = 803), tested on 567 radiographs (n = 244), and subsequently externally validated on 535 radiographs (n = 227). For characterization, healthy shoulders and glenohumeral dislocation were excluded. The overall accuracy for fracture detection was 94% (area under the receiver operating characteristic curve (AUC) = 0.98) and for classification 78% (AUC 0.68 to 0.93). Accuracy to detect greater tuberosity fracture displacement ≥ 1 cm was 35.0% (AUC 0.57). The CNN did not recognize NSAs ≤ 100° (AUC 0.42), nor fractures with ≥ 75% shaft translation (AUC 0.51 to 0.53), or with ≥ 15% articular involvement (AUC 0.48 to 0.49). For all objectives, the model’s performance on the external dataset showed similar accuracy levels. Conclusion. CNNs proficiently rule out proximal humerus fractures on plain radiographs. Despite rigorous training methodology based on CT imaging with multi-rater consensus to serve as the reference standard, artificial intelligence-driven classification is insufficient for clinical implementation. The CNN exhibited poor diagnostic ability to detect greater tuberosity displacement ≥ 1 cm and failed to identify NSAs ≤ 100°, shaft translations, or articular fractures. Cite this article: Bone Joint J 2024;106-B(11):1348–1360


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 128 - 135
1 Feb 2024
Jenkinson MRJ Cheung TCC Witt J Hutt JRB

Aims. The aim of this study is to evaluate whether acetabular retroversion (AR) represents a structural anatomical abnormality of the pelvis or is a functional phenomenon of pelvic positioning in the sagittal plane, and to what extent the changes that result from patient-specific functional position affect the extent of AR. Methods. A comparative radiological study of 19 patients (38 hips) with AR were compared with a control group of 30 asymptomatic patients (60 hips). CT scans were corrected for rotation in the axial and coronal planes, and the sagittal plane was then aligned to the anterior pelvic plane. External rotation of the hemipelvis was assessed using the superior iliac wing and inferior iliac wing angles as well as quadrilateral plate angles, and correlated with cranial and central acetabular version. Sagittal anatomical parameters were also measured and correlated to version measurements. In 12 AR patients (24 hips), the axial measurements were repeated after matching sagittal pelvic rotation with standing and supine anteroposterior radiographs. Results. Acetabular version was significantly lower and measurements of external rotation of the hemipelvis were significantly increased in the AR group compared to the control group. The AR group also had increased evidence of anterior projection of the iliac wing in the sagittal plane. The acetabular orientation angles were more retroverted in the supine compared to standing position, and the change in acetabular version correlated with the change in sagittal pelvic tilt. An anterior pelvic tilt of 1° correlated with 1.02° of increased cranial retroversion and 0.76° of increased central retroversion. Conclusion. This study has demonstrated that patients with symptomatic AR have both an externally rotated hemipelvis and increased anterior projection of the iliac wing compared to a control group of asymptomatic patients. Functional sagittal pelvic positioning was also found to affect AR in symptomatic patients: the acetabulum was more retroverted in the supine position compared to standing position. Changes in acetabular version correlate with the change in sagittal pelvic tilt. These findings should be taken into account by surgeons when planning acetabular correction for AR with periacetabular osteotomy. Cite this article: Bone Joint J 2024;106-B(2):128–135


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1284 - 1292
1 Nov 2024
Moroder P Poltaretskyi S Raiss P Denard PJ Werner BC Erickson BJ Griffin JW Metcalfe N Siegert P

Aims. The objective of this study was to compare simulated range of motion (ROM) for reverse total shoulder arthroplasty (rTSA) with and without adjustment for scapulothoracic orientation in a global reference system. We hypothesized that values for simulated ROM in preoperative planning software with and without adjustment for scapulothoracic orientation would be significantly different. Methods. A statistical shape model of the entire humerus and scapula was fitted into ten shoulder CT scans randomly selected from 162 patients who underwent rTSA. Six shoulder surgeons independently planned a rTSA in each model using prototype development software with the ability to adjust for scapulothoracic orientation, the starting position of the humerus, as well as kinematic planes in a global reference system simulating previously described posture types A, B, and C. ROM with and without posture adjustment was calculated and compared in all movement planes. Results. All movement planes showed significant differences when comparing protocols with and without adjustment for posture. The largest mean difference was seen in external rotation, being 62° (SD 16°) without adjustment compared to 25° (SD 9°) with posture adjustment (p < 0.001), with the highest mean difference being 49° (SD 15°) in type C. Mean extension was 57° (SD 18°) without adjustment versus 24° (SD 11°) with adjustment (p < 0.001) and the highest mean difference of 47° (SD 18°) in type C. Mean abducted internal rotation was 69° (SD 11°) without adjustment versus 31° (SD 6°) with posture adjustment (p < 0.001), showing the highest mean difference of 51° (SD 11°) in type C. Conclusion. The present study demonstrates that accounting for scapulothoracic orientation has a significant impact on simulated ROM for rTSA in all motion planes, specifically rendering vastly lower values for external rotation, extension, and high internal rotation. The substantial differences observed in this study warrant a critical re-evaluation of all previously published studies that examined component choice and placement for optimized ROM in rTSA using conventional preoperative planning software. Cite this article: Bone Joint J 2024;106-B(11):1284–1292


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1697 - 1702
1 Dec 2020
Schormans PMJ Kooijman MA Ten Bosch JA Poeze M Hannemann PFW

Aims. Fixation of scaphoid nonunion with a volar locking plate and cancellous bone grafting has been shown to be a successful technique in small series. Few mid- or long-term follow-up studies have been reported. The aim of this study was to report the mid-term radiological and functional outcome of plate fixation for scaphoid nonunion. Methods. Patients with a scaphoid nonunion were prospectively enrolled and treated with open reduction using a volar approach, debridement of the nonunion, and fixation using a locking plate and cancellous bone grafting, from the ipsilateral iliac crest. Follow-up included examination, functional assessment using the patient-rated wrist/hand evaluation (PRWHE), and multiplanar reformation CT scans at three-month intervals until union was confirmed. Results. A total of 49 patients with a mean age of 31 years (16 to 74) and a mean duration of nonunion of 3.6 years (0.4 to 16) were included. Postoperatively, the nonunion healed in 47 patients (96%) as shown on CT scans. The mean time to union was 4.2 months (3 to 12). Due to impingement of the plate on the volar rim of the radius and functional limitation, the hardware was removed in 18 patients. At a median follow-up of 38 months in 34 patients, the mean active range of motion (ROM) improved significantly from 89° to 124° (SD 44°; p = 0.003). The mean grip strength improved significantly from 52% to 79% (SD 28%; p < 0.001) of the contralateral side. The mean PRWHE score improved significantly from 66 to 17 points (SD 25; p < 0.001). Conclusion. Locking plate fixation supplemented with autologous cancellous bone grafting is a successful form of treatment for scaphoid nonunion. Functional outcomes improve with the passage of time, and mid-term results are excellent with a significant improvement in ROM, grip strength, and functional outcome as measured by the PRWHE. Cite this article: Bone Joint J 2020;102-B(12):1697–1702


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 817 - 825
1 Aug 2024
Borukhov I Ismailidis P Esposito CI LiArno S Lyon J McEwen PJ

Aims. This study aimed to evaluate if total knee arthroplasty (TKA) femoral components aligned in either mechanical alignment (MA) or kinematic alignment (KA) are more biomimetic concerning trochlear sulcus orientation and restoration of trochlear height. Methods. Bone surfaces from 1,012 CT scans of non-arthritic femora were segmented using a modelling and analytics system. TKA femoral components (Triathlon; Stryker) were virtually implanted in both MA and KA. Trochlear sulcus orientation was assessed by measuring the distal trochlear sulcus angle (DTSA) in native femora and in KA and MA prosthetic femoral components. Trochlear anatomy restoration was evaluated by measuring the differences in medial, lateral, and sulcus trochlear height between native femora and KA and MA prosthetic femoral components. Results. Femoral components in both MA and KA alignments exhibited a more valgus DTSA compared to native femora. However, DTSA deviation from native was significantly less in KA than in MA (4.8° (SD 2.2°) vs 8.8° (SD 1.8°); p < 0.001). DTSA deviation from native orientation correlated positively with the mechanical lateral distal femoral angle (mLDFA) in KA and negatively in MA (r = 0.53, p < 0.001; r = -0.18, p < 0.001). Medial trochlear height was not restored with either MA or KA, with MA resulting in lower medial trochlear height than KA in the proximal 20% of the trochlea. Lateral and sulcus trochlear height was not restored with either alignment in the proximal 80% of the trochlea. At the terminal arc point, KA replicated sulcus and lateral trochlear height, while MA led to over-restoration. Conclusion. Femoral components aligned in KA demonstrated greater biomimetic qualities than those in MA regarding trochlear sulcus orientation and trochlear height restoration, particularly in valgus femora. Variability across knees was observed, warranting further research to evaluate the clinical implications of these findings. Cite this article: Bone Joint J 2024;106-B(8):817–825


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 964 - 969
1 Sep 2024
Wang YC Song JJ Li TT Yang D Lv ZB Wang ZY Zhang ZM Luo Y

Aims. To propose a new method for evaluating paediatric radial neck fractures and improve the accuracy of fracture angulation measurement, particularly in younger children, and thereby facilitate planning treatment in this population. Methods. Clinical data of 117 children with radial neck fractures in our hospital from August 2014 to March 2023 were collected. A total of 50 children (26 males, 24 females, mean age 7.6 years (2 to 13)) met the inclusion criteria and were analyzed. Cases were excluded for the following reasons: Judet grade I and Judet grade IVb (> 85° angulation) classification; poor radiograph image quality; incomplete clinical information; sagittal plane angulation; severe displacement of the ulna fracture; and Monteggia fractures. For each patient, standard elbow anteroposterior (AP) view radiographs and corresponding CT images were acquired. On radiographs, Angle P (complementary to the angle between the long axis of the radial head and the line perpendicular to the physis), Angle S (complementary to the angle between the long axis of the radial head and the midline through the proximal radial shaft), and Angle U (between the long axis of the radial head and the straight line from the distal tip of the capitellum to the coronoid process) were identified as candidates approximating the true coronal plane angulation of radial neck fractures. On the coronal plane of the CT scan, the angulation of radial neck fractures (CTa) was measured and served as the reference standard for measurement. Inter- and intraobserver reliabilities were assessed by Kappa statistics and intraclass correlation coefficient (ICC). Results. Angle U showed the strongest correlation with CTa (p < 0.001). In the analysis of inter- and intraobserver reliability, Kappa values were significantly higher for Angles S and U compared with Angle P. ICC values were excellent among the three groups. Conclusion. Angle U on AP view was the best substitute for CTa when evaluating radial neck fractures in children. Further studies are required to validate this method. Cite this article: Bone Joint J 2024;106-B(9):964–969


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1636 - 1645
1 Dec 2020
Lerch TD Liechti EF Todorski IAS Schmaranzer F Steppacher SD Siebenrock KA Tannast M Klenke FM

Aims. The prevalence of combined abnormalities of femoral torsion (FT) and tibial torsion (TT) is unknown in patients with femoroacetabular impingement (FAI) and hip dysplasia. This study aimed to determine the prevalence of combined abnormalities of FT and TT, and which subgroups are associated with combined abnormalities of FT and TT. Methods. We retrospectively evaluated symptomatic patients with FAI or hip dysplasia with CT scans performed between September 2011 and September 2016. A total of 261 hips (174 patients) had a measurement of FT and TT. Their mean age was 31 years (SD 9), and 63% were female (165 hips). Patients were compared to an asymptomatic control group (48 hips, 27 patients) who had CT scans including femur and tibia available for analysis, which had been acquired for nonorthopaedic reasons. Comparisons were conducted using analysis of variance with Bonferroni correction. Results. In the overall study group, abnormal FT was present in 62% (163 hips). Abnormal TT was present in 42% (109 hips). Normal FT combined with normal TT was present in 21% (55 hips). The most frequent abnormal combination was increased FT combined with normal TT of 32% (84 hips). In the hip dysplasia group, 21% (11 hips) had increased FT combined with increased TT. The prevalence of abnormal FT varied significantly among the subgroups (p < 0.001). We found a significantly higher mean FT for hip dysplasia (31°; SD 15)° and valgus hips (42° (SD 12°)) compared with the control group (22° (SD 8°)). We found a significantly higher mean TT for hips with cam-type-FAI (34° (SD 6°)) and hip dysplasia (35° (SD 9°)) compared with the control group (28° (SD 8°)) (p < 0.001). Conclusion. Patients with FAI had a high prevalence of combined abnormalities of FT and TT. For hip dysplasia, we found a significantly higher mean FT and TT, while 21% of patients (11 hips) had combined increased TT and increased FT (combined torsional malalignment). This is important when planning hip preserving surgery such as periacetabular osteomy and femoral derotation osteotomy. Cite this article: Bone Joint J 2020;102-B(12):1636–1645


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 874 - 880
1 Jul 2020
Langerhuizen DWG Bergsma M Selles CA Jaarsma RL Goslings JC Schep NWL Doornberg JN

Aims. The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging. Methods. A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard. Results. In order to detect dorsal screw penetration, the sensitivity of dorsal tangential views was 39% with a negative predictive value (NPV) of 91% and an accuracy of 91%; compared with a sensitivity of 25% for 3D fluoroscopy with a NPV of 93% and an accuracy of 93%. On the postoperative CT scans, we found penetrating screws in: 1) 40% of patients in the 2D fluoroscopy group; 2) in 32% of those in the 2D fluoroscopy group with AP, lateral, and dorsal tangential views; and 3) in 25% of patients in the 3D fluoroscopy group. In all three groups, the second compartment was prone to penetration, while the postoperative incidence decreased when more advanced imaging was used. There were no penetrating screws in the third compartment (extensor pollicis longus groove) in the 3D fluoroscopy groups, and one in the dorsal tangential views group. Conclusion. Advanced intraoperative imaging helps to identify screws which have penetrated the dorsal compartments of the wrist. However, based on diagnostic performance characteristics, one cannot conclude that 3D fluoroscopy outperforms dorsal tangential views when used for this purpose. Dorsal tangential views are sufficiently accurate to detect dorsal screw penetration, and arguably more efficacious than 3D fluoroscopy. Cite this article: Bone Joint J 2020;102-B(7):874–880


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1165 - 1175
1 Oct 2024
Frost Teilmann J Petersen ET Thillemann TM Hemmingsen CK Olsen Kipp J Falstie-Jensen T Stilling M

Aims. The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA). Methods. Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom. Results. The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly. Conclusion. The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA. Cite this article: Bone Joint J 2024;106-B(10):1165–1175


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 254 - 260
1 Mar 2023
Bukowski BR Sandhu KP Bernatz JT Pickhardt PJ Binkley N Anderson PA Illgen R

Aims. Osteoporosis can determine surgical strategy for total hip arthroplasty (THA), and perioperative fracture risk. The aims of this study were to use hip CT to measure femoral bone mineral density (BMD) using CT X-ray absorptiometry (CTXA), determine if systematic evaluation of preoperative femoral BMD with CTXA would improve identification of osteopenia and osteoporosis compared with available preoperative dual-energy X-ray absorptiometry (DXA) analysis, and determine if improved recognition of low BMD would affect the use of cemented stem fixation. Methods. Retrospective chart review of a single-surgeon database identified 78 patients with CTXA performed prior to robotic-assisted THA (raTHA) (Group 1). Group 1 was age- and sex-matched to 78 raTHAs that had a preoperative hip CT but did not have CTXA analysis (Group 2). Clinical demographics, femoral fixation method, CTXA, and DXA data were recorded. Demographic data were similar for both groups. Results. Preoperative femoral BMD was available for 100% of Group 1 patients (CTXA) and 43.6% of Group 2 patients (DXA). CTXA analysis for all Group 1 patients preoperatively identified 13 osteopenic and eight osteoporotic patients for whom there were no available preoperative DXA data. Cemented stem fixation was used with higher frequency in Group 1 versus Group 2 (28.2% vs 14.3%, respectively; p = 0.030), and in all cases where osteoporosis was diagnosed, irrespective of technique (DXA or CTXA). Conclusion. Preoperative hip CT scans which are routinely obtained prior to raTHA can determine bone health, and thus guide femoral fixation strategy. Systematic preoperative evaluation with CTXA resulted in increased recognition of osteopenia and osteoporosis, and contributed to increased use of cemented femoral fixation compared with routine clinical care; in this small study, however, it did not impact short-term periprosthetic fracture risk. Cite this article: Bone Joint J 2023;105-B(3):254–260


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 262 - 268
1 Feb 2018
Puri A Ranganathan P Gulia A Crasto S Hawaldar R Badwe RA

Aims. A single-centre prospective randomized trial was conducted to investigate whether a less intensive follow-up protocol would not be inferior to a conventional follow-up protocol, in terms of overall survival, in patients who have undergone surgery for sarcoma of the limb. Initial short-term results were published in 2014. Patients and Methods. The primary objective was to show non-inferiority of a chest radiograph (CXR) group compared with a CT scan group, and of a less frequent (six-monthly) group than a more frequent (three-monthly) group, in two-by-two comparison. The primary outcome was overall survival and the secondary outcome was a recurrence-free survival. Five-year survival was compared between the CXR and CT scan groups and between the three-monthly and six-monthly groups. Of 500 patients who were enrolled, 476 were available for follow-up. Survival analyses were performed on a per-protocol basis (n = 412). Results. The updated results recorded 12 (2.4%) local recurrences, 182 (36.8%) metastases, and 56 (11.3%) combined (local + metastases) recurrence at a median follow-up of 81 months (60 to 118). Of 68 local recurrences, 60 (88%) were identified by the patients themselves. The six-monthly regime (overall survival (OS) 54%, recurrence-free survival (RFS) 46%) did not lead to a worse survival and was not inferior to the three-monthly regime (OS 55%, RFS 47%) in terms of detecting recurrence. Although CT scans (OS 53%, RFS 54%) detected pulmonary metastasis earlier, it did not lead to a better survival compared with CXR (OS 56%, RFS 59%). Conclusion. The overall survival of patients who are treated for a sarcoma of the limb is not inferior to those followed up with a less intensive regimen than a more intensive protocol, in terms of frequency of visits and mode of imaging. CXR at six-monthly intervals and patient education about examination of the site of the surgery will detect most recurrences without deleterious effects on the eventual outcome. Cite this article: Bone Joint J 2018;100-B:262–8


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 324 - 335
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS

Aims. Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. Methods. This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery. Results. There were no significant differences for any of the baseline characteristics including spinopelvic mobility. The absolute error for achieving the planned horizontal COR was median 1.4 mm (interquartile range (IQR) 0.87 to 3.42) in RO THA versus 4.3 mm (IQR 3 to 6.8; p < 0.001); vertical COR mean 0.91 mm (SD 0.73) in RO THA versus 2.3 mm (SD 1.3; p < 0.001); and combined offset median 2 mm (IQR 0.97 to 5.45) in RO THA versus 3.9 mm (IQR 2 to 7.9; p = 0.019). Improved accuracy was observed with RO THA in achieving the desired acetabular component positioning (root mean square error for anteversion and inclination was 2.6 and 1.3 vs 8.9 and 5.3, repectively) and leg length (mean 0.6 mm vs 1.4 mm; p < 0.001). Patient-reported outcome measures were comparable between the two groups at baseline and one year. Participants in the RO THA group needed fewer physiotherapy sessions postoperatively (median six (IQR 4.5 to 8) vs eight (IQR 6 to 11; p = 0.005). Conclusion. This RCT suggested that robotic-arm assistance in THA was associated with improved accuracy in restoring the native COR, better preservation of the combined offset, leg length correction, and superior accuracy in achieving the desired acetabular component positioning. Further evaluation through long-term and registry data is necessary to assess whether these findings translate into improved implant survival and functional outcomes. Cite this article: Bone Joint J 2024;106-B(4):324–335


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1497 - 1504
1 Sep 2021
Rotman D Ariel G Rojas Lievano J Schermann H Trabelsi N Salai M Yosibash Z Sternheim A

Aims. Type 2 diabetes mellitus (T2DM) impairs bone strength and is a significant risk factor for hip fracture, yet currently there is no reliable tool to assess this risk. Most risk stratification methods rely on bone mineral density, which is not impaired by diabetes, rendering current tests ineffective. CT-based finite element analysis (CTFEA) calculates the mechanical response of bone to load and uses the yield strain, which is reduced in T2DM patients, to measure bone strength. The purpose of this feasibility study was to examine whether CTFEA could be used to assess the hip fracture risk for T2DM patients. Methods. A retrospective cohort study was undertaken using autonomous CTFEA performed on existing abdominal or pelvic CT data comparing two groups of T2DM patients: a study group of 27 patients who had sustained a hip fracture within the year following the CT scan and a control group of 24 patients who did not have a hip fracture within one year. The main outcome of the CTFEA is a novel measure of hip bone strength termed the Hip Strength Score (HSS). Results. The HSS was significantly lower in the study group (1.76 (SD 0.46)) than in the control group (2.31 (SD 0.74); p = 0.002). A multivariate model showed the odds of having a hip fracture were 17 times greater in patients who had an HSS ≤ 2.2. The CTFEA has a sensitivity of 89%, a specificity of 76%, and an area under the curve of 0.90. Conclusion. This preliminary study demonstrates the feasibility of using a CTFEA-based bone strength parameter to assess hip fracture risk in a population of T2DM patients. Cite this article: Bone Joint J 2021;103-B(9):1497–1504


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 317 - 324
1 Mar 2019
Moon J Kim Y Hwang K Yang J Ryu J Kim Y

Aims. The present study investigated the five-year interval changes in pseudotumours and measured serum metal ions at long-term follow-up of a previous report of 28 mm diameter metal-on-metal (MoM) total hip arthroplasty (THA). Patients and Methods. A total of 72 patients (mean age 46.6 years (37 to 55); 43 men, 29 women; 91 hips) who underwent cementless primary MoM THA with a 28 mm modular head were included. The mean follow-up duration was 20.3 years (18 to 24). All patients had CT scans at a mean 15.1 years (13 to 19) after the index operation and subsequent follow-up at a mean of 20.2 years (18 to 24). Pseudotumour volume, type of mass, and new-onset pseudotumours were evaluated using CT scanning. Clinical outcomes were assessed by Harris Hip Score (HHS) and the presence of groin pain. Serum metal ion (cobalt (Co) and chromium (Cr)) levels were measured at the latest follow-up. Results. At final follow-up, pseudotumours were observed in 26/91 hips (28.6%). There was an increase in volume of the pseudotumour in four hips (15.4%), no change in volume in 21 hips (80.8%), and a decrease in volume in one hip (3.8%). There were no new-onset pseudotumours. There was no significant difference in HHS between patients with and without pseudotumours. At final follow-up, mean serum Co ion levels and median Co:Cr ratios were significantly greater in patients with pseudotumours, but the serum Cr ion levels were not significantly different. Conclusion. At a mean 20 years of follow-up, pseudotumours were observed in 26/91 hips (28.6%) with no new-onset pseudotumours during subsequent follow-up. Most pseudotumours in small-head MoM THA were static in volume and asymptomatic with normal serum metal ion levels. Cite this article: Bone Joint J 2019;101-B:317–324


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 475 - 479
1 Apr 2018
Ali AA Forrester RA O’Connor P Harris NJ

Aims. The aim of this study was to present a series of patients with aseptic failure of a total ankle arthroplasty (TAA) who were treated with fusion of the hindfoot using a nail. Patients and Methods. A total of 23 TAAs, in 22 patients, were revised for aseptic loosening and balloon osteolysis to a hindfoot fusion by a single surgeon (NH) between January 2012 and August 2014. The procedure was carried out without bone graft using the Phoenix, Biomet Hindfoot Arthrodesis Nail. Preoperative investigations included full blood count, CRP and ESR, and radiological investigations including plain radiographs and CT scans. Postoperative plain radiographs were assessed for fusion. When there was any doubt, CT scans were performed. Results. The mean follow-up was 13.9 months (4.3 to 37.2). Union occurred at the tibiotalar joint in 22 ankles (95.6%) with one partial union. Union occurred at the subtalar joint in 20 ankles (87%) of cases with two nonunions. The nail broke in one patient with a subtalar nonunion and revision was undertaken. The only other noted complication was one patient who suffered a stress fracture at the proximal aspect of the nail, which was satisfactorily treated conservatively. Conclusion. This study represents the largest group of patients reported to have undergone revision TAA to fusion of the hindfoot with good results. Cite this article: Bone Joint J 2018;100-B:475–9


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1301 - 1308
1 Jul 2021
Sugiura K Morimoto M Higashino K Takeuchi M Manabe A Takao S Maeda T Sairyo K

Aims. Although lumbosacral transitional vertebrae (LSTV) are well-documented, few large-scale studies have investigated thoracolumbar transitional vertebrae (TLTV) and spinal numerical variants. This study sought to establish the prevalence of numerical variants and to evaluate their relationship with clinical problems. Methods. A total of 1,179 patients who had undergone thoracic, abdominal, and pelvic CT scanning were divided into groups according to the number of thoracic and lumbar vertebrae, and the presence or absence of TLTV or LSTV. The prevalence of spinal anomalies was noted. The relationship of spinal anomalies to clinical symptoms (low back pain, Japanese Orthopaedic Association score, Roland-Morris Disability Questionnaire) and degenerative spondylolisthesis (DS) was also investigated. Results. Normal vertebral morphology (12 thoracic and five lumbar vertebrae without TLTV and LSTV) was present in 531 male (76.7%) and 369 female patients (75.8%). Thoracolumbar transitional vertebrae were present in 15.8% of males and 16.0% of females. LSTV were present in 7.1% of males and 9.0% of females. The prevalence of the anomaly of 16 presacral mobile vertebrae (total number of thoracolumbar vertebrae and TLTV) without LSTV was 1.0% in males and 4.1% in females, and that of the anomaly of 18 vertebrae without LSTV was 5.3% in males and 1.2% in females. The prevalence of DS was significantly higher in females with a total of 16 vertebrae than in those with normal morphology. There was no significant correlation between a spinal anomaly and clinical symptoms. Conclusion. Overall, 24% of subjects had anomalies in the thoracolumbar region: the type of anomaly differed between males and females, which could have significant implications for spinal surgery. A decreased number of vertebrae was associated with DS: numerical variants may potentially be a clinical problem. Cite this article: Bone Joint J 2021;103-B(7):1301–1308


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 617 - 621
1 May 2018
Uehara M Takahashi J Ikegami S Kuraishi S Fukui D Imamura H Okada K Kato H

Aims. Although we often encounter patients with an aortic aneurysm who also have diffuse idiopathic skeletal hyperostosis (DISH), there are no reports to date of an association between these two conditions and the pathogenesis of DISH remains unknown. This study therefore evaluated the prevalence of DISH in patients with a thoracic aortic aneurysm (AA). Patients and Methods. The medical records of 298 patients who underwent CT scans for a diagnosis of an AA or following high-energy trauma were retrospectively examined. A total of 204 patients underwent surgery for an AA and 94 had a high-energy injury and formed the non-AA group. The prevalence of DISH was assessed on CT scans of the chest and abdomen and the relationship between DISH and AA by comparison between the AA and non-AA groups. Results. The prevalence of DISH in the AA group (114/204; 55.9%) was higher than that in the non-AA group (31/94; 33.0%). On multivariate analysis, the factors of AA, male gender, and ageing were independent predictors of the existence of DISH, with odds ratios of 2.9, 1.9, and 1.03, respectively. Conclusion. This study revealed that the prevalence of DISH is higher in patients with an AA than in those without an AA, and that the presence of an AA significantly influenced the prevalence of DISH. Cite this article: Bone Joint J 2018;100-B:617–21


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 640 - 645
1 May 2018
Frietman B Biert J Edwards MJR

Aims. The aim of this study was to record the incidence of post-traumatic osteoarthritis (OA), the need for total hip arthroplasty (THA), and patient-reported outcome measures (PROMS) after surgery for a fracture of the acetabulum, in our centre. Patients and Methods. All patients who underwent surgery for an acetabular fracture between 2004 and 2014 were included. Patients completed the 36-Item Short Form Health Survey (SF-36) and the modified Harris Hip Score (mHHS) questionnaires. A retrospective chart and radiographic review was performed on all patients. CT scans were used to assess the classification of the fracture and the quality of reduction. Results. A total of 220 patients were included, of which 55 (25%) developed post-traumatic OA and 33 (15%) underwent THA. A total of 164 patients completed both questionnaires. At a mean follow-up of six years (2 to 10), the mean SF-36 score for patients with a preserved hip joint was higher on role limitations due to physical health problems than for those with OA or those who underwent THA. In the dimension of bodily pain, patients with OA had a significantly better score than those who underwent THA. Patients with a preserved hip joint had a significantly better score on the function scale of the mHHS and a better total score than those with OA or who underwent THA. Conclusion. Of the patients who were treated surgically for an acetabular fracture (with a mean follow-up of six years), 15% underwent THA at a mean of 2.75 years postoperatively. Patients with a THA had a worse functional outcome than those who retain their native hip joint. We recommend using PROMS and CT scans when reviewing these patients. Cite this article: Bone Joint J 2018;100-B:640–5


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 674 - 679
1 May 2017
Nuttall D Birch A Haines JF Watts AC Trail IA

Aims. Radiostereometric analysis (RSA) allows an extremely accurate measurement of early micromotion of components following arthroplasty. . Patients and Methods. In this study, RSA was used to measure the migration of 11 partially cemented fluted pegged glenoid components in patients with osteoarthritis who underwent total shoulder arthroplasty using an improved surgical technique (seven men, four women, mean age 68). Patients were evaluated clinically using the American Shoulder and Elbow Surgeons (ASES) and Constant-Murley scores and by CT scans two years post-operatively. . Results. There were two patterns of migration, the first showing little, if any, migration and the second showing rotation by > 6° as early as three months post-operatively. At two years, these two groups could be confirmed on CT scans, one with osseointegration around the central peg, and the second with cystic changes. Patients with osteolysis around the central peg were those with early migration and those with osseointegration had minimal early migration. Both groups,however,had similar clinical results. . Conclusion. Rapid early migration associated with focal lucency and absence of osseointegration was observed in three of 11 glenoid components, suggesting that lack of initial stability leads to early movement and failure of osseointegration. Cite this article: Bone Joint J 2017;99-B:674–9


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 766 - 771
1 Jun 2009
Brunner A Honigmann P Treumann T Babst R

We evaluated the impact of stereo-visualisation of three-dimensional volume-rendering CT datasets on the inter- and intraobserver reliability assessed by kappa values on the AO/OTA and Neer classifications in the assessment of proximal humeral fractures. Four independent observers classified 40 fractures according to the AO/OTA and Neer classifications using plain radiographs, two-dimensional CT scans and with stereo-visualised three-dimensional volume-rendering reconstructions. Both classification systems showed moderate interobserver reliability with plain radiographs and two-dimensional CT scans. Three-dimensional volume-rendered CT scans improved the interobserver reliability of both systems to good. Intraobserver reliability was moderate for both classifications when assessed by plain radiographs. Stereo visualisation of three-dimensional volume rendering improved intraobserver reliability to good for the AO/OTA method and to excellent for the Neer classification. These data support our opinion that stereo visualisation of three-dimensional volume-rendering datasets is of value when analysing and classifying complex fractures of the proximal humerus


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1303 - 1309
1 Oct 2018
Nodzo SR Chang C Carroll KM Barlow BT Banks SA Padgett DE Mayman DJ Jerabek SA

Aims. The aim of this study was to evaluate the accuracy of implant placement when using robotic assistance during total hip arthroplasty (THA). Patients and Methods. A total of 20 patients underwent a planned THA using preoperative CT scans and robotic-assisted software. There were nine men and 11 women (n = 20 hips) with a mean age of 60.8 years (. sd. 6.0). Pelvic and femoral bone models were constructed by segmenting both preoperative and postoperative CT scan images. The preoperative anatomical landmarks using the robotic-assisted system were matched to the postoperative 3D reconstructions of the pelvis. Acetabular and femoral component positions as measured intraoperatively and postoperatively were evaluated and compared. Results. The system reported accurate values for reconstruction of the hip when compared to those measured postoperatively using CT. The mean deviation from the executed overall hip length and offset were 1.6 mm (. sd. 2.9) and 0.5 mm (. sd. 3.0), respectively. Mean combined anteversion was similar and correlated between intraoperative measurements and postoperative CT measurements (32.5°, . sd. 5.9° versus 32.2°, . sd. 6.4°; respectively; R. 2. = 0.65; p < 0.001). There was a significant correlation between mean intraoperative (40.4°, . sd. 2.1°) acetabular component inclination and mean measured postoperative inclination (40.12°, . sd. 3.0°, R. 2. = 0.62; p < 0.001). There was a significant correlation between mean intraoperative version (23.2°, . sd. 2.3°), and postoperatively measured version (23.0°, . sd. 2.4°; R. 2. = 0.76; p < 0.001). Preoperative and postoperative femoral component anteversion were significantly correlated with one another (R. 2. = 0.64; p < 0.001). Three patients had CT scan measurements that differed substantially from the intraoperative robotic measurements when evaluating stem anteversion. Conclusion. This is the first study to evaluate the success of hip reconstruction overall using robotic-assisted THA. The overall hip reconstruction obtained in the operating theatre using robotic assistance accurately correlated with the postoperative component position assessed independently using CT based 3D modelling. Clinical correlation during surgery should continue to be practiced and compared with observed intraoperative robotic values. Cite this article: Bone Joint J 2018;100-B:1303–9


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 79 - 84
1 Jun 2020
Abdelfadeel W Houston N Star A Saxena A Hozack WJ

Aims. The aim of this study was to analyze the true costs associated with preoperative CT scans performed for robotic-assisted total knee arthroplasty (RATKA) planning and to determine the value of a formal radiologist’s report of these studies. Methods. We reviewed 194 CT reports of 176 sequential patients who underwent primary RATKA by a single surgeon at a suburban teaching hospital. CT radiology reports were reviewed for the presence of incidental findings that might change the management of the patient. Payments for the scans, including the technical and professional components, for 330 patients at two hospitals were also recorded and compared. Results. There were 82 incidental findings in 61 CT studies, one of which led to a recommendation for additional testing. Across both institutions, the mean total payment for a preoperative scan was $446 ($8 to $3,870). The mean patient payment was $71 ($0 to $2,690). There was wide variation in payments between the institutions. In Institution A, the mean total payment was $258 ($168 to $264), with a mean patient payment of $57 ($0 to $100). The mean technical payment in this institution was $211 ($8 to $856), while the mean professional payment was $48 ($0 to $66). In Institution B, the mean total payment was $636 ($37 to $3,870), with a mean patient payment of $85 ($0 to $2,690). Conclusion. The total cost of a CT scan is low and a minimal part of the overall cost of the RATKA. No incidental findings identified on imaging led to a change in management, suggesting that the professional component could be eliminated to reduce costs. Further studies need to take into account the patient perspective and the wide variation in total costs and patient payments across institutions and insurances. Cite this article: Bone Joint J 2020;102-B(6 Supple A):79–84


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 638 - 645
1 May 2020
Sternheim A Traub F Trabelsi N Dadia S Gortzak Y Snir N Gorfine M Yosibash Z

Aims. Accurate estimations of the risk of fracture due to metastatic bone disease in the femur is essential in order to avoid both under-treatment and over-treatment of patients with an impending pathological fracture. The purpose of the current retrospective in vivo study was to use CT-based finite element analyses (CTFEA) to identify a clear quantitative differentiating factor between patients who are at imminent risk of fracturing their femur and those who are not, and to identify the exact location of maximal weakness where the fracture is most likely to occur. Methods. Data were collected on 82 patients with femoral metastatic bone disease, 41 of whom did not undergo prophylactic fixation. A total of 15 had a pathological fracture within six months following the CT scan, and 26 were fracture-free during the five months following the scan. The Mirels score and strain fold ratio (SFR) based on CTFEA was computed for all patients. A SFR value of 1.48 was used as the threshold for a pathological fracture. The sensitivity, specificity, positive, and negative predicted values for Mirels score and SFR predictions were computed for nine patients who fractured and 24 who did not, as well as a comparison of areas under the receiver operating characteristic curves (AUC of the ROC curves). Results. The sensitivity of SFR was 100% compared with 88% for the Mirels score, and the specificity of SFR was 67% compared with 38% for the Mirels score. The AUC was 0.905 for SFR compared with 0.578 for the Mirels score (p = 0.008). Conclusion. All the patients who sustained a pathological fracture of the femur had an SFR of > 1.48. CTFEA was far better at predicting the risk of fracture and its location accurately compared with the Mirels score. CTFEA is quick and automated and can be incorporated into the protocol of CT scanners. Cite this article: Bone Joint J 2020;102-B(5):638–645


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 232 - 238
1 Feb 2020
Javed S Hadi S Imam MA Gerogiannis D Foden P Monga P

Aims. Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the ‘classic’ Friedman method. Methods. This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary TSA. The glenoid version was measured using the Friedman and Ellipse methods by two senior observers. Statistical analyses were performed using the paired t-test for significance and the Bland-Altman plot for agreement. Results. The mean glenoid version was -3.11° (-23.8° to 17.9°) using the Friedman method and -1.95° (-29.8° to 24.6°) using the Ellipse method (p = 0.002). In 16 patients the difference between methods was greater than 5°, which we considered to be clinically significant. There was poor agreement between methods with relatively large 95% limits of agreement. There was excellent inter-rater agreement between the observers for the Ellipse method and similarly, the intrarater agreement was excellent with a repeatability coefficient of 0.94. Conclusion. We recommend the use of the Ellipse modification to define the mid glenoid point prior to measuring the glenoid version in patients undergoing TSA. Cite this article: Bone Joint J 2020;102-B(2):232–238


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 374 - 380
1 Mar 2016
Kocsis G Thyagarajan DS Fairbairn KJ Wallace WA

Aims. Glenoid bone loss can be a challenging problem when revising a shoulder arthroplasty. Precise pre-operative planning based on plain radiographs or CT scans is essential. We have investigated a new radiological classification system to describe the degree of medialisation of the bony glenoid and that will indicate the amount of bone potentially available for supporting a glenoid component. It depends on the relationship between the most medial part of the articular surface of the glenoid with the base of the coracoid process and the spinoglenoid notch: it classifies the degree of bone loss into three types. It also attempts to predict the type of glenoid reconstruction that may be possible (impaction bone grafting, structural grafting or simple non-augmented arthroplasty) and gives guidance about whether a pre-operative CT scan is indicated. Patients and Methods. Inter-method reliability between plain radiographs and CT scans was assessed retrospectively by three independent observers using data from 39 randomly selected patients. . Inter-observer reliability and test-retest reliability was tested on the same cohort using Cohen's kappa statistics. Correlation of the type of glenoid with the Constant score and its pain component was analysed using the Kruskal-Wallis method on data from 128 patients. Anatomical studies of the scapula were reviewed to explain the findings. Results. Excellent inter-method reliability, inter-observer and test-retest reliability were seen. The system did not correlate with the Constant score, but correlated well with its pain component. . Take home message: Our system of classification is a helpful guide to the degree of glenoid bone loss when embarking on revision shoulder arthroplasty. Cite this article: Bone Joint J 2016;98-B:374–80


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 597 - 603
1 May 2014
Nomura T Naito M Nakamura Y Ida T Kuroda D Kobayashi T Sakamoto T Seo H

Several radiological methods of measuring anteversion of the acetabular component after total hip replacement (THR) have been described. These studies used different definitions and reference planes to compare methods, allowing for misinterpretation of the results. We compared the reliability and accuracy of five current methods using plain radiographs (those of Lewinnek, Widmer, Liaw, Pradhan, and Woo and Morrey) with CT measurements, using the same definition and reference plane. We retrospectively studied the plain radiographs and CT scans in 84 hips of 84 patients who underwent primary THR. Intra- and inter-observer reliability were high for the measurement of inclination and anteversion with all methods on plain radiographs and CT scans. The measurements of inclination on plain radiographs were similar to the measurements using CT (p = 0.043). The mean difference between CT measurements was 0.6° (-5.9° to 6.8°). Measurements using Widmer’s method were the most similar to those using CT (p = 0.088), with a mean difference between CT measurements of -0.9° (-10.4° to 9.1°), whereas the other four methods differed significantly from those using CT (p < 0.001). This study has shown that Widmer’s method is the best for evaluating the anteversion of the acetabular component on plain radiographs. Cite this article: Bone Joint J 2014; 96-B:597–603


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 868 - 873
1 Jul 2020
Yang G Dai Y Dong C Kang H Niu J Lin W Wang F

Aims. The purpose of this study was to explore the correlation between femoral torsion and morphology of the distal femoral condyle in patients with trochlear dysplasia and lateral patellar instability. Methods. A total of 90 patients (64 female, 26 male; mean age 22.1 years (SD 7.2)) with lateral patellar dislocation and trochlear dysplasia who were awaiting surgical treatment between January 2015 and June 2019 were retrospectively analyzed. All patients underwent CT scans of the lower limb to assess the femoral torsion and morphology of the distal femur. The femoral torsion at various levels was assessed using the a) femoral anteversion angle (FAA), b) proximal and distal anteversion angle, c) angle of the proximal femoral axis-anatomical epicondylar axis (PFA-AEA), and d) angle of the AEA–posterior condylar line (AEA-PCL). Representative measurements of distal condylar length were taken and parameters using the ratios of the bianterior condyle, biposterior condyle, bicondyle, anterolateral condyle, and anteromedial condyle were calculated and correlated with reference to the AEA, using the Pearson Correlation coefficient. Results. The femoral torsion had a strong correlation with distal condylar morphology. The FAA was significantly correlated with the ratio of the bianterior condyle (r = 0.355; p = 0.009), the AEA-PCL angle (r = 0.340; p = 0.001) and the ratio of the anterolateral condyle and lateral condyle (ALC-LC) (r = 0.309; p = 0.014). The PFA-AEA angle was also significantly correlated with the ratio of the bianterior condyle (r = 0.319; p = 0.008), the AEA-PCL angle (r = 0.231; p = 0.031), and the ratio of ALC-LC (r = 0.261; p = 0.034). In addition, the bianterior condyle ratio showed a significant correlation with the biposterior condyle ratio (r = -0.324; p = 0.027) and the AEA-PCL angle (r = 0.342; p = 0.021). Conclusion. Increased femoral torsion correlated with a prominent anterolateral condyle and a shorter posterolateral condyle compared with the medial condyle. The deformities of the anterior and posterior condyles are combined deformities rather than being isolated and individual deformities in patients with trochlear dysplasia and patella instability. Cite this article: Bone Joint J 2020;102-B(7):868–873


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 32 - 36
1 Jan 2012
Nho J Lee Y Kim HJ Ha Y Suh Y Koo K

A variety of radiological methods of measuring version of the acetabular component after total hip replacement (THR) have been described. The aim of this study was to evaluate the reliability and validity of six methods (those of Lewinnek; Widmer; Hassan et al; Ackland, Bourne and Uhthoff; Liaw et al; and Woo and Morrey) that are currently in use. In 36 consecutive patients who underwent THR, version of the acetabular component was measured by three independent examiners on plain radiographs using these six methods and compared with measurements using CT scans. The intra- and interobserver reliabilities of each measurement were estimated. All measurements on both radiographs and CT scans had excellent intra- and interobserver reliability and the results from each of the six methods correlated well with the CT measurements. However, measurements made using the methods of Widmer and of Ackland, Bourne and Uhthoff were significantly different from the CT measurements (both p < 0.001), whereas measurements made using the remaining four methods were similar to the CT measurements. With regard to reliability and convergent validity, we recommend the use of the methods described by Lewinnek, Hassan et al, Liaw et al and Woo and Morrey for measurement of version of the acetabular component


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 212 - 219
1 Feb 2020
Ræder BW Figved W Madsen JE Frihagen F Jacobsen SB Andersen MR

Aims. In a randomized controlled trial with two-year follow-up, patients treated with suture button (SB) for acute syndesmotic injury had better outcomes than patients treated with syndesmotic screw (SS). The aim of this study was to compare clinical and radiological outcomes for these treatment groups after five years. Methods. A total of 97 patients with acute syndesmotic injury were randomized to SS or SB. The five-year follow-up rate was 81 patients (84%). The primary outcome was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Scale. Secondary outcome measures included Olerud-Molander Ankle (OMA) score, visual analogue scale (VAS), EuroQol five-dimension questionnaire (EQ-5D), range of movement, complications, reoperations, and radiological results. CT scans of both ankles were obtained after surgery, and after one, two, and five years. Results. The SB group had higher median AOFAS score (100 (interquartile range (IQR) 92 to 100) vs 90 (IQR 85 to 100); p = 0.006) and higher median OMA score (100 (IQR 95 to 100) vs 95 (IQR 75 to 100); p = 0.006). The SS group had a higher incidence of ankle osteoarthritis (OA) (24 (65%) vs 14 (35%), odds ratio (OR) 3.4 (95% confidence interval (CI) 1.3 to 8.8); p = 0.009). On axial CT we measured a significantly smaller mean difference in the anterior tibiofibular distance between injured and non-injured ankles in the SB group (–0.1 mm vs 1.2 mm; p = 0.016). Conclusion. Five years after syndesmotic injury treated with either SB or SS, we found better AOFAS and OMA scores, and lower incidence of ankle OA, in the SB group. These long-term results favour the use of SB when treating an acute syndesmotic injury. Cite this article: Bone Joint J 2020;102-B(2):212–219


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 910 - 914
1 Aug 2019
Kiran M Donnelly TD Armstrong C Kapoor B Kumar G Peter V

Aims. Prosthetic joint infection (PJI) and aseptic loosening in total hip arthroplasty (THA) can present with pain and osteolysis. The Musculoskeletal Infection Society (MSIS) has provided criteria for the diagnosis of PJI. The aim of our study was to analyze the utility of F18-fluorodeoxyglucose (FDG) positron emission tomography (PET) CT scan in the preoperative diagnosis of septic loosening in THA, based on the current MSIS definition of prosthetic joint infection. Patients and Methods. A total of 130 painful unilateral cemented THAs with a mean follow-up of 5.17 years (. sd. 1.12) were included in this prospective study. The mean patient age was 67.5 years (. sd. 4.85). Preoperative evaluation with inflammatory markers, aspiration, and an F18 FDG PET scan were performed. Diagnostic utility tests were also performed, based on the MSIS criteria for PJI and three samples positive on culture alone. Results. The mean erythrocyte sedimentation rate, C-reactive protein, and white cell count were 47.83 mm/hr, 25.21 mg/l, and 11.05 × 10. 9. /l, respectively. The sensitivity, specificity, accuracy, negative predictive value, and false-positive rate of FDG PET compared with MSIS criteria were 94.87%, 38.46 %, 56.38%, 94.59 %, and 60.21%, respectively. The false-positive rate of FDG PET compared with culture alone was 77.4%. Conclusion. FDG PET has a definitive role in the preoperative evaluation of suspected PJI. This the first study to evaluate its utility based on MSIS criteria and compare it with microbiology results alone. However, FDG PET has a high false-positive rate. Therefore, we suggest that F18 FDG PET is useful in confirming the absence of infection, but if positive, may not be confirmatory of PJI. Cite this article: Bone Joint J 2019;101-B:910–914


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims. We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency. Patients and Methods. A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection. Results. Of the 45 patients, 16 had anatomical shoulder arthroplasties (ASA) and 29 had reverse shoulder arthroplasties (RSA). Postoperatively, 43/45 patients had a CT scan. In 41 of 43 patients (95%), the glenoid peg achieved > 50% integration. In 40 of 43 cases (93%), the graft was fully or partially integrated. There were seven revisions (16%) but only four (9%) required a change of baseplate. Four (25%) of the 16 ASAs were revised for instability or cuff failure. At two-year radiological follow-up, five of the 41 cases (11%) showed some evidence of lucent lines. Conclusion. The use of a metal baseplate with a trabecular titanium surface in conjunction with autologous bone graft is a reliable method of addressing glenoid bone defects in primary and revision RSA setting in the short term. ASAs have a higher rate of complications with this technique


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 560 - 564
1 Apr 2010
Miller AN Prasarn ML Lorich DG Helfet DL

We have examined the accuracy of reduction and the functional outcomes in elderly patients with surgically treated acetabular fractures, based on assessment of plain radiographs and CT scans. There were 45 patients with such a fracture with a mean age of 67 years (59 to 82) at the time of surgery. All patients completed SF-36 questionnaires to determine the functional outcome at a mean follow-up of 72.4 months (24 to 188). All had radiographs and a CT scan within one week of surgery. The reduction was categorised as ‘anatomical’, ‘imperfect’, or ‘poor’. Radiographs classified 26 patients (58%) as anatomical,13 (29%) as imperfect and six (13%) as poor. The maximum displacement on CT showed none as anatomical, 23 (51%) as imperfect and 22 (49%) as poor, but this was not always at the weight-bearing dome. SF-36 scores showed functional outcomes comparable with those of the general elderly population, with no correlation with the radiological reduction. Perfect anatomical reduction is not necessary to attain a good functional outcome in acetabular fractures in the elderly


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 398 - 404
1 Mar 2012
Seide K Aljudaibi M Weinrich N Kowald B Jürgens C Müller J Faschingbauer M

In an interdisciplinary project involving electronic engineers and clinicians, a telemetric system was developed to measure the bending load in a titanium internal femoral fixator. As this was a new device, the main question posed was: what clinically relevant information could be drawn from its application? As a first clinical investigation, 27 patients (24 men, three women) with a mean age of 38.4 years (19 to 66) with femoral nonunions were treated using the system. The mean duration of the nonunion was 15.4 months (5 to 69). The elasticity of the plate-callus system was measured telemetrically until union. Conventional radiographs and a CT scan at 12 weeks were performed routinely, and healing was staged according to the CT scans. All nonunions healed at a mean of 21.5 weeks (13 to 37). Well before any radiological signs of healing could be detected, a substantial decrease in elasticity was recorded. The relative elasticity decreased to 50% at a mean of 7.8 weeks (3.5 to 13) and to 10% at a mean of 19.3 weeks (4.5 to 37). At 12 weeks the mean relative elasticity was 28.1% (0% to 56%). The relative elasticity was significantly different between the different healing stages as determined by the CT scans. Incorporating load measuring electronics into implants is a promising option for the assessment of bone healing. Future application might lead to a reduction in the need for exposure to ionising radiation to monitor fracture healing


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 103 - 109
1 Jan 2010
Laffosse J Espié A Bonnevialle N Mansat P Tricoire J Bonnevialle P Chiron P Puget J

We retrospectively analysed the clinical results of 30 patients with injuries of the sternoclavicular joint at a minimum of 12 months’ follow-up. A closed reduction was attempted in 14 cases. It was successful in only five of ten dislocations, and failed in all four epiphyseal disruptions. A total of 25 patients underwent surgical reduction, in 18 cases in conjunction with a stabilisation procedure. At a mean follow-up of 60 months, four patients were lost to follow-up. The functional results in the remainder were satisfactory, and 18 patients were able to resume their usual sports activity at the same level. There was no statistically significant difference between epiphyseal disruption and sternoclavicular dislocation (p > 0.05), but the functional scores (Simple Shoulder Test, Disability of Arm, Shoulder, Hand, and Constant scores) were better when an associated stabilisation procedure had been performed rather than reduction alone (p = 0.05, p = 0.04 and p = 0.07, respectively). We recommend meticulous pre-operative clinical assessment with CT scans. In sternoclavicular dislocation managed within the first 48 hours and with no sign of mediastinal complication, a closed reduction can be attempted, although this was unsuccessful in half of our cases. A control CT scan is mandatory. In all other cases, and particularly if epiphyseal disruption is suspected, we recommend open reduction with a stabilisation procedure by costaclavicular cerclage or tenodesis. The use of a Kirschner wire should be avoided


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 477 - 482
1 Apr 2012
Merle C Waldstein W Pegg E Streit MR Gotterbarm T Aldinger PR Murray DW Gill HS

The aim of this retrospective cohort study was to identify any difference in femoral offset as measured on pre-operative anteroposterior (AP) radiographs of the pelvis, AP radiographs of the hip and corresponding CT scans in a consecutive series of 100 patients with primary end-stage osteoarthritis of the hip (43 men and 57 women with a mean age of 61 years (45 to 74) and a mean body mass index of 28 kg/m. 2. (20 to 45)). Patients were positioned according to a standardised protocol to achieve reproducible projection and all images were calibrated. Inter- and intra-observer reliability was evaluated and agreement between methods was assessed using Bland-Altman plots. In the entire cohort, the mean femoral offset was 39.0 mm (95% confidence interval (CI) 37.4 to 40.6) on radiographs of the pelvis, 44.0 mm (95% CI 42.4 to 45.6) on radiographs of the hip and 44.7 mm (95% CI 43.5 to 45.9) on CT scans. AP radiographs of the pelvis underestimated femoral offset by 13% when compared with CT (p < 0.001). No difference in mean femoral offset was seen between AP radiographs of the hip and CT (p = 0.191). Our results suggest that femoral offset is significantly underestimated on AP radiographs of the pelvis but can be reliably and accurately assessed on AP radiographs of the hip in patients with primary end-stage hip osteoarthritis. We, therefore, recommend that additional AP radiographs of the hip are obtained routinely for the pre-operative assessment of femoral offset when templating before total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1513 - 1518
1 Nov 2006
Henckel J Richards R Lozhkin K Harris S Baena FMRY Barrett ARW Cobb JP

Surgeons need to be able to measure angles and distances in three dimensions in the planning and assessment of knee replacement. Computed tomography (CT) offers the accuracy needed but involves greater radiation exposure to patients than traditional long-leg standing radiographs, which give very little information outside the plane of the image. There is considerable variation in CT radiation doses between research centres, scanning protocols and individual scanners, and ethics committees are rightly demanding more consistency in this area. By refining the CT scanning protocol we have reduced the effective radiation dose received by the patient down to the equivalent of one long-leg standing radiograph. Because of this, it will be more acceptable to obtain the three-dimensional data set produced by CT scanning. Surgeons will be able to document the impact of implant position on outcome with greater precision


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1413 - 1419
1 Nov 2017
Solan MC Sakellariou A

The posterior malleolus component of a fracture of the ankle is important, yet often overlooked. Pre-operative CT scans to identify and classify the pattern of the fracture are not used enough. Posterior malleolus fractures are not difficult to fix. After reduction and fixation of the posterior malleolus, the articular surface of the tibia is restored; the fibula is out to length; the syndesmosis is more stable and the patient can rehabilitate faster. There is therefore considerable merit in fixing most posterior malleolus fractures. An early post-operative CT scan to ensure that accurate reduction has been achieved should also be considered. Cite this article: Bone Joint J 2017;99-B:1413–19


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 120 - 125
1 Jan 2011
Lim H Bae J Song H Teoh SH Kim H Kum D

Medial open-wedge high tibial osteotomy has been gaining popularity in recent years, but adequate supporting material is required in the osteotomy gap for early weight-bearing and rapid union. The purpose of this study was to investigate whether the implantation of a polycaprolactone-tricalcium phosphate composite scaffold wedge would enhance healing of the osteotomy in a micro pig model. We carried out open-wedge high tibial osteotomies in 12 micro pigs aged from 12 to 16 months. A scaffold wedge was inserted into six of the osteotomies while the other six were left open. Bone healing was evaluated after three and six months using plain radiographs, CT scans, measurement of the bone mineral density and histological examination. Complete bone union was obtained at six months in both groups. There was no collapse at the osteotomy site, loss of correction or failure of fixation in either group. Staining with haematoxylin and eosin demonstrated that there was infiltration of new bone tissue into the macropores and along the periphery of the implanted scaffold in the scaffold group. The CT scans and measurement of the bone mineral density showed that at six months specimens in the scaffold group had a higher bone mineral density than in the control group, although the implantation of the polycaprolactone-tricalcium phosphate composite scaffold wedge did not enhance healing of the osteotomy


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 566 - 569
1 May 2018
White TO

The posterior malleolus of the ankle is the object of increasing attention, with considerable enthusiasm for CT scanning and surgical fixation, as expressed in a recent annotation in The Bone & Joint Journal. Undoubtedly, fractures with a large posterior malleolar fragment that allow posterior talar subluxation from the mortise are served better by fixation. However, in all other situations, the existing literature does not support this widespread change in practice. The available biomechanical evidence shows that the posterior malleolus has little part to play in the stability or contact stresses of the ankle joint. Radiographic studies have not shown that CT scanning offers helpful information on pathoanatomical classification, case selection, or prognosis, or that scanning improves the likelihood of an adequate surgical reduction. Clinical studies have not shown any improvement in patient outcome after surgical fixation, and have confirmed that the inevitable consequence of increased intervention is an increased rate of complications. A careful and thoughtful evaluation of indications, risks, and benefits of this fashionable concept is required to ensure that we are deploying valuable resources with efficacy, and that we do no harm. Cite this article: Bone Joint J 2018;100-B:566–9


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1377 - 1382
1 Oct 2013
Walch G Mesiha M Boileau P Edwards TB Lévigne C Moineau G Young A

Osteoarthritis results in changes in the dimensions of the glenoid. This study aimed to assess the size and radius of curvature of arthritic glenoids. A total of 145 CT scans were analysed, performed as part of routine pre-operative assessment before total shoulder replacement in 91 women and 54 men. Only patients with primary osteoarthritis and a concentric glenoid were included in the study. The CT scans underwent three-dimensional (3D) reconstruction and were analysed using dedicated computer software. The measurements consisted of maximum superoinferior height, anteroposterior width and a best-fit sphere radius of curvature of the glenoid. The mean height was 40.2 mm (. sd. 4.9), the mean width was 29 mm (. sd. 4.3) and the mean radius of curvature was 35.4 mm (. sd. 7.8). The measurements were statistically different in men and women and had a Gaussian distribution with marked variation. All measurements were greater than the known values in normal subjects. With current shoulder replacement systems using a unique backside radius of curvature for the glenoid component, there is a risk of undertaking excessive reaming to adapt the bone to the component resulting in sacrifice of subchondral bone or under-reaming and instability of the component due to a ’rocking horse‘ phenomenon. . Cite this article: Bone Joint J 2013;95-B:1377–82


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 712 - 719
1 Jun 2018
Batailler C Weidner J Wyatt M Dalmay F Beck M

Aims. The primary aim of this study was to define and quantify three new measurements to indicate the position of the greater trochanter. Secondary aims were to define ‘functional antetorsion’ as it relates to abductor function in populations both with and without torsional abnormality. Patients and Methods. Three new measurements, functional antetorsion, posterior tilt, and posterior translation of the greater trochanter, were assessed from 61 CT scans of cadaveric femurs, and their reliability determined. These measurements and their relationships were also evaluated in three groups of patients: a control group (n = 22), a ‘high-antetorsion’ group (n = 22) and a ‘low-antetorsion’ group (n = 10). Results. In the cadaver group, the mean anatomical antetorsion was 14.7° (. sd. 8.5; 0 to 36.5) and the functional antetorsion 21.5° (. sd. 8.1; 3.6 to 44.3): the posterior tilt was 73.3° (. sd. 10.8; 46.9 to 88.7) and the posterior translation 0.59 (. sd. 0.2; 0.2 to 0.9). These measurements had excellent intra and interobserver agreement with a range from 0.93 to 0.99. When the anatomical antetorsion decreased, the greater trochanter was more tilted and translated posteriorly in relation to the axis of the femoral neck, and the difference between functional and anatomical antetorsion increased. The results the three patient groups were similar to those of the cadaver group. Conclusion. The position of the greater trochanter and functional antetorsion varied with anatomical antetorsion. In the surgical management of femoral retrotorsion, subtrochanteric osteotomy can result in an excessively posterior position of the greater trochanter and an increase in functional antetorsion. Cite this article: Bone Joint J 2018;100-B:712–19


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1474 - 1479
1 Nov 2006
Magnan B Bortolazzi R Marangon A Marino M Dall’Oca C Bartolozzi P

A minimally-invasive procedure using percutaneous reduction and external fixation can be carried out for Sanders’ type II, III and IV fractures of the os calcis. We have treated 54 consecutive closed displaced fractures of the calcaneum involving the articular surface in 52 patients with the Orthofix Calcaneal Mini-Fixator. Patients were followed up for a mean of 49 months (27 to 94) and assessed clinically with the Maryland Foot Score and radiologically with radiographs and CT scans, evaluated according to the Score Analysis of Verona. The clinical results at follow-up were excellent or good in 49 cases (90.7%), fair in two (3.7%) and poor in three (5.6%). The mean pre-operative Böhler’s angle was 6.98° (5.95° to 19.86°), whereas after surgery the mean value was 21.94° (12.58° to 31.30°) (p < 0.01). Excellent results on CT scanning were demonstrated in 24 cases (44.4%), good in 25 (46.3%), fair in three (5.6%) and poor in two (3.7%). Transient local osteoporosis was observed in ten patients (18.5%), superficial pin track infection in three (5.6%), and three patients (5.6%) showed thalamic displacement following unadvised early weight-bearing. The clinical results appear to be comparable with those obtainable with open reduction and internal fixation, with the advantages of reduced risk using a minimally-invasive technique


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims. Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. Methods. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature. Results. Quantitative MRI revealed a mean reduction of 21.2% (SD 1.3%) of arterial contribution in the lateral plating group and 25.4% (SD 3.2%) in the dual plating group (p = 0.051); representing a mean decrease in arterial contribution of 4.2%. The only significant difference found between both experimental groups was regionally, at the lateral aspect of the distal femur with a mean drop in arterial contribution in the lateral plating group of 18.9% (SD 2.6%) versus 24.0% (SD 3.2%) in the dual plating group (p = 0.048), representing a mean decrease in arterial contribution of 5.1%. Gross dissection revealed complete destruction of periosteal vessels underneath either medial or lateral plates in both groups. The network of genicular branches contributing to the posterior and distal femoral condyles was preserved in all specimens. A medial vascular pedicle was found dividing from the superficial femoral artery at a mean 12.7 cm (SD 1.7) proximal to the medial epicondyle and was undisrupted in the dual plating group. Conclusion. Lateral locking-plate application resulted in mean 21.2% reduction in distal femur vascularity. Addition of medial plates did not further markedly decrease vascularity. As such, the majority of the vascular insult occurred with lateral plating alone. Supplemental medially based fixation did not lead to marked devascularization of the distal femur, and should therefore be considered in the setting of comminution and poor bone stock in distal femoral fractures. Further clinical research is required to confirm the results of this study. Cite this article: Bone Joint J 2020;102-B(4):530–538


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 461 - 467
1 Apr 2018
Wagener J Schweizer C Zwicky L Horn Lang T Hintermann B

Aims. Arthroscopically controlled fracture reduction in combination with percutaneous screw fixation may be an alternative approach to open surgery to treat talar neck fractures. The purpose of this study was thus to present preliminary results on arthroscopically reduced talar neck fractures. Patients and Methods. A total of seven consecutive patients (four women and three men, mean age 39 years (19 to 61)) underwent attempted surgical treatment of a closed Hawkins type II talar neck fracture using arthroscopically assisted reduction and percutaneous screw fixation. Functional and radiological outcome were assessed using plain radiographs, as well as weight-bearing and non-weight-bearing CT scans as tolerated. Patient satisfaction and pain sensation were also recorded. Results. Primary reduction was obtained arthroscopically in all but one patient, for whom an interposed fracture fragment had to be removed through a small arthrotomy to permit anatomical reduction. The quality of arthroscopic reduction and restoration of the talar geometry was excellent in the remaining six patients. There were no signs of talar avascular necrosis or subtalar degeneration in any of the patients. In the whole series, the functional outcome was excellent in five patients but restricted ankle movement was observed in two patients. All patients had a reduction in subtalar movement. At final follow-up, all patients were satisfied and all but one patient were pain free. Conclusion. Arthroscopically assisted reduction and fixation of talar neck fractures was found to be a feasible treatment option and allowed early functional rehabilitation. Cite this article: Bone Joint J 2018;100-B:461–7


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 590 - 595
1 May 2018
Sawa M Nakasa T Ikuta Y Yoshikawa M Tsuyuguchi Y Kanemitsu M Ota Y Adachi N

Aims. The aim of this study was to evaluate antegrade autologous bone grafting with the preservation of articular cartilage in the treatment of symptomatic osteochondral lesions of the talus with subchondral cysts. Patients and Methods. The study involved seven men and five women; their mean age was 35.9 years (14 to 70). All lesions included full-thickness articular cartilage extending through subchondral bone and were associated with subchondral cysts. Medial lesions were exposed through an oblique medial malleolar osteotomy, and one lateral lesion was exposed by expanding an anterolateral arthroscopic portal. After refreshing the subchondral cyst, it was grafted with autologous cancellous bone from the distal tibial metaphysis. The fragments of cartilage were fixed with 5-0 nylon sutures to the surrounding cartilage. Function was assessed at a mean follow-up of 25.3 months (15 to 50), using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot outcome score. The radiological outcome was assessed using MRI and CT scans. Results. The mean AOFAS score improved from 65.7 (47 to 81) preoperatively to 92 (90 to 100) at final follow-up, with 100% patient satisfaction. The radiolucent area of the cysts almost disappeared on plain radiographs in all patients immediately after surgery, and there were no recurrences at the most recent follow-up. The medial malleolar screws were removed in seven patients, although none had symptoms. At this time, further arthroscopy was undertaken, when it was found that the mean International Cartilage Repair Society (ICRS) arthroscopic score represented near-normal cartilage. Conclusion. Autologous bone grafting with fixation of chondral fragments preserves the original cartilage in the short term, and could be considered in the treatment for adult patients with symptomatic osteochondral defect and subchondral cysts. Cite this article: Bone Joint J 2018;100-B:590–5


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 570 - 578
1 May 2018
Gollwitzer H Suren C Strüwind C Gottschling H Schröder M Gerdesmeyer L Prodinger PM Burgkart R

Aims. Asphericity of the femoral head-neck junction is common in cam-type femoroacetabular impingement (FAI) and usually quantified using the alpha angle on radiographs or MRI. The aim of this study was to determine the natural alpha angle in a large cohort of patients by continuous circumferential analysis with CT. Methods. CT scans of 1312 femurs of 656 patients were analyzed in this cross-sectional study. There were 362 men and 294 women. Their mean age was 61.2 years (18 to 93). All scans had been performed for reasons other than hip disease. Digital circumferential analysis allowed continuous determination of the alpha angle around the entire head-neck junction. All statistical tests were conducted two-sided; a p-value < 0.05 was considered statistically significant. Results. The mean maximum alpha angle for the cohort was 59.0° (. sd. 9.4). The maximum was located anterosuperiorly at 01:36 on the clock face, with two additional maxima of asphericity at the posterior and inferior head-neck junction. The mean alpha angle was significantly larger in men (59.4°, . sd. 8.0) compared with women (53.5°, . sd. 7.4°; p = 0.0005), and in Caucasians (60.7°, . sd. 9.0°) compared with Africans (56.3°, . sd. 8.0; p = 0.007) and Asians (50.8°, . sd. 7.2; p = 0.0005). The alpha angle showed a weak positive correlation with age (p < 0.05). If measured at commonly used planes of the radially reconstructed CT or MRI, the alpha angle was largely underestimated; measurement at the 01:30 and 02:00 positions showed a mean underestimation of 4° and 6°, respectively. Conclusion. This study provides important data on the normal alpha angle dependent on age, gender, and ethnic origin. The normal alpha angle in men is > 55°, and this should be borne in mind when making a diagnosis of cam-type morphology. Cite this article: Bone Joint J 2018;100-B:570–8


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 845 - 852
1 Jul 2018
Langston J Pierrepont J Gu Y Shimmin A

Aims. It is important to consider sagittal pelvic rotation when introducing the acetabular component at total hip arthroplasty (THA). The purpose of this study was to identify patients who are at risk of unfavourable pelvic mobility, which could result in poor outcomes after THA. Patients and Methods. A consecutive series of 4042 patients undergoing THA had lateral functional radiographs and a low-dose CT scan to measure supine pelvic tilt, pelvic incidence, standing pelvic tilt, flexed-seated pelvic tilt, standing lumbar lordotic angle, flexed-seated lumbar lordotic angle, and lumbar flexion. Changes in pelvic tilt from supine-to-standing positions and supine-to-flexed-seated positions were determined. A change in pelvic tilt of 13° between positions was deemed unfavourable as it alters functional anteversion by 10° and effectively places the acetabular component outside the safe zone of orientation. Results. For both men and women, the degree of lumbar flexion was a significant predictor of risk in hip flexion (p < 0.0001) with increased odds of unfavourable pelvic mobility in those with lumbar flexion of < 20° (men, odds ratio (OR) 6.74, 95% confidence interval (CI) 3.83 to 11.89; women, OR 2.97, 95% CI 1.87 to 4.71). In women, age and standing pelvic tilt were significant predictors of risk in hip extension (p = 0.0082 and p < 0.0001, respectively). The risk of unfavourable pelvic mobility was higher in those aged > 75 years (OR 2.28, 95% CI 1.56 to 3.32) and those with standing pelvic tilt of < -10° for extension risk (OR 7.10, 95% CI 4.10 to 10.29). In men, only standing pelvic tilt was significant (p < 0.0001) for hip extension with an increased risk of unfavourable pelvic mobility (OR 8.68, 95% CI 5.19 to 14.51). Conclusion. Patients found to have unfavourable pelvic mobility had limited lumbar flexion and more posterior standing pelvic tilt in both men and women, as well as increasing age in women. We recommend that patients undergo preoperative functional radiographic screening to determine specific parameters that can affect the functional orientation of the acetabular component. Cite this article: Bone Joint J 2018;100-B:845–52


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1373 - 1380
1 Oct 2017
Rienmüller A Buchmann N Kirschke JS Meyer EL Gempt J Lehmberg J Meyer B Ryang YM

Aims. We aimed to retrospectively assess the accuracy and safety of CT navigated pedicle screws and to compare accuracy in the cervical and thoracic spine (C2-T8) with (COMB) and without (POST) prior anterior surgery (anterior cervical discectomy or corpectomy and fusion with ventral plating: ACDF/ACCF). Patients and Methods. A total of 592 pedicle screws, which were used in 107 consecutively operated patients (210 COMB, 382 POST), were analysed. The accuracy of positioning was determined according to the classification of Gertzbein and Robbins on post-operative CT scans. Results. High accuracy was achieved in 524 screws (88.5%), 192 (87.7%) in the cervical spine and 332 (89%) in the thoracic spine, respectively. The results in the two surgical groups were compared and a logistic regression mixed model was performed to analyse the risk of low accuracy. Significantly lower accuracy was found in the COMB group with 82.9% versus 91.6% in the POST group (p = 0.036). There were no neurological complications, but two vertebral artery lesions were recorded. Three patients underwent revision surgery for malpositioning of a screw. Although the risk of malpositioning of a screw after primary anterior surgery was estimated to be 2.4-times higher than with posterior surgery alone, the overall rates of complication and revision were low. Conclusion. We therefore conclude that CT navigated pedicle screws can be positioned safely although greater caution must be taken in patients who have previously undergone anterior surgery. Cite this article: Bone Joint J 2017;99-B:1373–80


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 556 - 557
1 Aug 1987
Hougaard K Lindequist S Nielsen L

We have reviewed 19 consecutive patients admitted to the Odense University Hospital after traumatic dislocation of the hip. We aimed to perform computerised tomography as soon as possible after closed reduction; this was accomplished in 15 patients. The CT scans revealed intra-articular fragments of bone in five hips, and fractures of the femoral head or acetabulum in six. In two cases the CT scans excluded fractures or intra-articular fragments which had been suspected on conventional radiography. CT scanning is a useful diagnostic tool in traumatic dislocation of the hip; we consider that it makes an important contribution to management


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 894 - 903
1 Jul 2017
Bonnin MP Saffarini M Nover L van der Maas J Haeberle C Hannink G Victor J

Aims. The morphometry of the distal femur was largely studied to improve bone-implant fit in total knee arthroplasty (TKA), but little is known about the asymmetry of the posterior condyles. This study aimed to investigate the dimensions of the posterior condyles and the influence of externally rotating the femoral component on potential prosthetic overhang or under-coverage. Patients and Methods. We analysed the shape of 110 arthritic knees at the time of primary TKA using pre-operative CT scans. The height and width of each condyle were measured at the posterior femoral cut in neutral position, and in 3º and 5º of external rotation, using both central and medial referencing systems. We compared the morphological characteristics with those of 14 TKA models. Results. In the neutral position, the dimensions of the condyles were nearly equal. Externally rotating the femoral cut by 3º and 5º with ‘central referencing’ induced width asymmetry >  3 mm in 23 (21%) and 33 (30%) knees respectively, while with ‘medial referencing’ it induced width asymmetry > 3 mm in 43 (39%) and 75 (68%) knees respectively. The asymmetries induced by rotations were not associated with gender, aetiology or varus-valgus alignment. Conclusion. External rotation may amplify the asymmetry between the medial and lateral condyles, and exacerbate prosthetic overhang, particularly in the superolateral zone. ‘Central referencing’ guides result in less potential prosthetic overhang than ‘medial referencing’ guides. Cite this article: Bone Joint J 2017;99-B:894–903


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 81 - 86
1 Jun 2021
Mahfouz MR Abdel Fatah EE Johnson JM Komistek RD

Aims. The objective of this study is to assess the use of ultrasound (US) as a radiation-free imaging modality to reconstruct 3D anatomy of the knee for use in preoperative templating in knee arthroplasty. Methods. Using an US system, which is fitted with an electromagnetic (EM) tracker that is integrated into the US probe, allows 3D tracking of the probe, femur, and tibia. The raw US radiofrequency (RF) signals are acquired and, using real-time signal processing, bone boundaries are extracted. Bone boundaries and the tracking information are fused in a 3D point cloud for the femur and tibia. Using a statistical shaping model, the patient-specific surface is reconstructed by optimizing bone geometry to match the point clouds. An accuracy analysis was conducted for 17 cadavers by comparing the 3D US models with those created using CT. US scans from 15 users were compared in order to examine the effect of operator variability on the output. Results. The results revealed that the US bone models were accurate compared with the CT models (root mean squared error (RM)S: femur, 1.07 mm (SD 0.15); tibia, 1.02 mm (SD 0.13). Additionally, femoral landmarking proved to be accurate (transepicondylar axis: 1.07° (SD 0.65°); posterior condylar axis: 0.73° (SD 0.41°); distal condylar axis: 0.96° (SD 0.89°); medial anteroposterior (AP): 1.22 mm (SD 0.69); lateral AP: 1.21 mm (SD 1.02)). Tibial landmarking errors were slightly higher (posterior slope axis: 1.92° (SD 1.31°); and tubercle axis: 1.91° (SD 1.24°)). For implant sizing, 90% of the femora and 60% of the tibiae were sized correctly, while the remainder were only one size different from the required implant size. No difference was observed between moderate and skilled users. Conclusion. The 3D US bone models were proven to be closely matched compared with CT and suitable for preoperative planning. The 3D US is radiation-free and offers numerous clinical opportunities for bone visualization rapidly during clinic visits, to enable preoperative planning with implant sizing. There is potential to extend its application to 3D dynamic ligament balancing, and intraoperative registration for use with robots and navigation systems. Cite this article: Bone Joint J 2021;103-B(6 Supple A):81–86


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 673 - 678
1 Jul 1998
Yang KH Han DY Park HW Kang HJ Park JH

We report retrospective and prospective studies to identify the causes of fracture of the femoral neck associated with femoral shaft nailing on the same side. Of a total of 14 neck fractures in a series of 152 shaft nailings, eight were not visible on the initial pelvic radiographs. We used CT scans before and after operation, and fluoroscopy during the procedure in our prospective series, and reviewed abdominal CT scans retrospectively with the window set to bone level. Six of the eight undisplaced fractures were shown to have been present before operation, but two were iatrogenic. We recommend the preoperative use of CT scans of the femoral neck in high-risk patients such as those with associated fractures of the acetabulum, the distal femur or the patella. Early diagnosis will allow better general management and early fixation of the neck fracture


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 697 - 701
1 May 2017
Massa BSF Guarniero R Godoy Jr RM Rodrigues JC Montenegro NB Cordeiro FG

Aims. This pilot study aimed to evaluate prospectively the use of inlet radiographs of the hip as an alternative method of the assessment of reduction after the surgical treatment of developmental dysplasia of the hip (DDH). Patients and Methods. The children in this study underwent surgery between January 2013 and January 2015. All had inlet radiographs and CT scans post-operatively. Data were analysed by determining inter-observer reliability and intra-observer reproducibility, using the kappa value (K). Differences were settled by discussion between the two observers until a consensus was reached. The sensitivity and specificity of the radiographic and CT results were compared. A total of 26 radiographs were obtained from 23 children, with a mean age of 2.38 years (one to five). Results. Similar high levels of intra- and inter-observer agreement were observed (K = 0.834, 95% confidence interval (CI)). There was a high agreement between the radiographic and CT results (K = 0.834, 5% CI), with excellent sensitivity and a specificity of 95.5%. Conclusion. These results suggest that inlet radiographs may be a reliable method of assessing the reduction of the hip after the surgical treatment of DDH. Cite this article: Bone Joint J 2017;99-B:697–701


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1342 - 1346
1 Oct 2016
Spencer-Gardner L Pierrepont J Topham M Baré J McMahon S Shimmin AJ

Aims. Accurate placement of the acetabular component during total hip arthroplasty (THA) is an important factor in the success of the procedure. However, the reported accuracy varies greatly and is dependent upon whether free hand or navigated techniques are used. The aim of this study was to assess the accuracy of an instrument system that incorporates 3D printed, patient-specific guides designed to optimise the placement of the acetabular component. Patients and Methods. A total of 100 consecutive patients were prospectively enrolled and the accuracy of placement of the acetabular component was measured using post-operative CT scans. Results. The mean absolute deviation from the planned inclination and anteversion was 3.9° (0.0° to 13.6°) and 3.6° (0.0° to 12.9°), respectively. In 91% of cases the planned target of +/-10° was achieved for both inclination and anteversion. Conclusion. Accurate placement of the acetabular component can be achieved using patient-specific guides and is superior to free hand techniques and comparable to navigated and robotic techniques. Cite this article: Bone Joint J 2016;98-B:1342–6


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1416 - 1422
1 Nov 2019
Rohilla R Sharma PK Wadhwani J Rohilla S Beniwal R Singh R Devgan A

Aims. In this randomized study, we aimed to compare quality of regenerate in monolateral versus circular frame fixation in 30 patients with infected nonunion of tibia. Patients and Methods. Both groups were comparable in demographic and injury characteristics. A phantom (aluminium step wedge of increasing thickness) was designed to compare the density of regenerate on radiographs. A CT scan was performed at three and six months postoperatively to assess regenerate density. A total of 30 patients (29 male, one female; mean age 32.54 years (18 to 60)) with an infected nonunion of a tibial fracture presenting to our tertiary institute between June 2011 and April 2016 were included in the study. Results. The regenerate mineralization on radiographs was comparable in both groups at two, four, six, and ten months’ follow-up but the rail fixator group had statistically significant higher grades of mineralization when compared with the circular frame group at eight and 12 months’ follow-up. The regenerate mineralization was also higher in the rail fixator group than in the circular frame group on CT at three and six months, although this difference was not statistically significant. Conclusion. Overall, the regenerate mineralization was higher in the monolateral than the circular frame group. A monolateral fixator may be preferred in patients with infected nonunion of the tibia with bone defects up to 7 cm. Cite this article: Bone Joint J 2019;101-B:1416–1422


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1080 - 1085
1 Aug 2016
Gauci MO Boileau P Baba M Chaoui J Walch G

Aims. Patient-specific glenoid guides (PSGs) claim an improvement in accuracy and reproducibility of the positioning of components in total shoulder arthroplasty (TSA). The results have not yet been confirmed in a prospective clinical trial. Our aim was to assess whether the use of PSGs in patients with osteoarthritis of the shoulder would allow accurate and reliable implantation of the glenoid component. Patients and Methods. A total of 17 patients (three men and 14 women) with a mean age of 71 years (53 to 81) awaiting TSA were enrolled in the study. Pre- and post-operative version and inclination of the glenoid were measured on CT scans, using 3D planning automatic software. During surgery, a congruent 3D-printed PSG was applied onto the glenoid surface, thus determining the entry point and orientation of the central guide wire used for reaming the glenoid and the introduction of the component. Manual segmentation was performed on post-operative CT scans to compare the planned and the actual position of the entry point (mm) and orientation of the component (°). Results. The mean error in the accuracy of the entry point was -0.1 mm (standard deviation (. sd. ) 1.4) in the horizontal plane, and 0.8 mm (. sd. 1.3) in the vertical plane. The mean error in the orientation of the glenoid component was 3.4° (. sd. 5.1°) for version and 1.8° (. sd. 5.3°) for inclination. Conclusion. Pre-operative planning with automatic software and the use of PSGs provides accurate and reproducible positioning and orientation of the glenoid component in anatomical TSA. Cite this article: Bone Joint J 2016;98-B:1080–5


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1043 - 1049
1 Aug 2016
Huijbregts HJTAM Khan RJK Fick DP Hall MJ Punwar SA Sorensen E Reid MJ Vedove SD Haebich S

Aims. We conducted a randomised controlled trial to assess the accuracy of positioning and alignment of the components in total knee arthroplasty (TKA), comparing those undertaken using standard intramedullary cutting jigs and those with patient-specific instruments (PSI). Patients and Methods. There were 64 TKAs in the standard group and 69 in the PSI group. The post-operative hip-knee-ankle (HKA) angle and positioning was investigated using CT scans. Deviation of > 3° from the planned position was regarded as an outlier. The operating time, Oxford Knee Scores (OKS) and Short Form-12 (SF-12) scores were recorded. Results. There were 14 HKA-angle outliers (22%) in the standard group and nine (13%) in the PSI group (p = 0.251). The mean HKA-angle was 0.5° varus in the standard group and 0.2° varus in the PSI group (p = 0.492). The accuracy of alignment in the coronal and axial planes and the proportion of outliers was not different in the two groups. The femoral component was more flexed (p = 0.035) and there were significantly more tibial slope outliers (29% versus 13%) in the PSI group (p = 0.032). Operating time and the median three-month OKS were similar (p = 0.218 and p = 0.472, respectively). Physical and mental SF-12 scores were not significantly different at three months (p = 0.418 and p = 0.267, respectively) or at one year post-operatively (p = 0.114 and p = 0.569). The median one-year Oxford knee score was two points higher in the PSI group (p = 0.049). Conclusion. Compared with standard intramedullary jigs, the use of PSI did not significantly reduce the number of outliers or the mean operating time, nor did it clinically improve the accuracy of alignment or the median Oxford Knee Scores. Our data do not support the routine use of PSI when undertaking TKA. Cite this article: Bone Joint J 2016;98-B:1043–9


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 834 - 840
1 Jun 2017
Clarke-Jenssen J Røise O Storeggen SAØ Madsen JE

Aims. Our aim in this study was to describe the long-term survival of the native hip joint after open reduction and internal fixation of a displaced fracture of the acetabulum. We also present long-term clinical outcomes and risk factors associated with a poor outcome. Patients and Methods. A total of 285 patients underwent surgery for a displaced acetabular fracture between 1993 and 2005. For the survival analysis 253 were included, there were 197 men and 56 women with a mean age of 42 years (12 to 78). The mean follow-up of 11 years (1 to 20) was identified from our pelvic fracture registry. There were 99 elementary and 154 associated fracture types. For the long-term clinical follow-up, 192 patients with complete data were included. Their mean age was 40 years (13 to 78) with a mean follow-up of 12 years (5 to 20). Injury to the femoral head and acetabular impaction were assessed with CT scans and patients with an ipsilateral fracture of the femoral head were excluded. Results. A total of 36 patients underwent total hip arthroplasty (THA). The overall ten-year survival of the hip joint was 86% (95% confidence interval (CI) 81% to 90%) and the 20-year survival was 82% (95% CI 76% to 87%). Injury to the femoral head and acetabular impaction were the strongest predictors of failure, with the long-term survival rate falling towards 50% in these patients. The survival fell to 0% at three years when both these risk factors were present in patients aged > 60 years. Conclusion. The long-term survival of the native hip joint after acetabular fractures was good, but the presence of injury to the femoral head and acetabular impaction proved to be strong predictors of failure, especially in patients aged > 60 years. These patients may be better treated with a combination of open reduction and internal fixation and primary arthroplasty. Cite this article: Bone Joint J 2017;99-B:834–40


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 349 - 358
1 Mar 2016
Akiyama K Nakata K Kitada M Yamamura M Ohori T Owaki H Fuji T

Aims. We investigated changes in the axial alignment of the ipsilateral hip and knee after total hip arthroplasty (THA). . Patients and Methods. We reviewed 152 patients undergoing primary THA (163 hips; 22 hips in men, 141 hips in women) without a pre-operative flexion contracture. The mean age was 64 years (30 to 88). The diagnosis was osteoarthritis (OA) in 151 hips (primary in 18 hips, and secondary to dysplasia in 133) and non-OA in 12 hips. A posterolateral approach with repair of the external rotators was used in 134 hips and an anterior approach in 29 hips. We measured changes in leg length and offset on radiographs, and femoral anteversion, internal rotation of the hip and lateral patellar tilt on CT scans, pre- and post-operatively. . Results. The mean internal rotation increased by 11° (-15° to 46°) and was associated with underlying disease (OA), pre-operative range of internal rotation, gender, surgical approach, leg lengthening, and change of femoral anteversion (adjusted R. 2. : 0.253, p < 0.001). The mean lateral patellar tilt increased by 4° (-5° to 14°) and was associated with age, leg lengthening, and increment of hip internal rotation (adjusted R. 2. : 0.193, p < 0.001). Conclusion. Both internal rotation of the hip at rest and lateral patellar tilt are increased after THA. Changes in rotation after THA may affect gait, daily activities, the rate of dislocation of the hip, and ipsilateral knee pain. Take home message: Internal rotation of the hip at rest and lateral patellar tilt increase after THA. Cite this article: Bone Joint J 2016;98-B:349–58


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 927 - 933
1 Jul 2017
Poltaretskyi S Chaoui J Mayya M Hamitouche C Bercik MJ Boileau P Walch G

Aims. Restoring the pre-morbid anatomy of the proximal humerus is a goal of anatomical shoulder arthroplasty, but reliance is placed on the surgeon’s experience and on anatomical estimations. The purpose of this study was to present a novel method, ‘Statistical Shape Modelling’, which accurately predicts the pre-morbid proximal humeral anatomy and calculates the 3D geometric parameters needed to restore normal anatomy in patients with severe degenerative osteoarthritis or a fracture of the proximal humerus. Materials and Methods. From a database of 57 humeral CT scans 3D humeral reconstructions were manually created. The reconstructions were used to construct a statistical shape model (SSM), which was then tested on a second set of 52 scans. For each humerus in the second set, 3D reconstructions of four diaphyseal segments of varying lengths were created. These reconstructions were chosen to mimic severe osteoarthritis, a fracture of the surgical neck of the humerus and a proximal humeral fracture with diaphyseal extension. The SSM was then applied to the diaphyseal segments to see how well it predicted proximal morphology, using the actual proximal humeral morphology for comparison. Results. With the metaphysis included, mimicking osteoarthritis, the errors of prediction for retroversion, inclination, height, radius of curvature and posterior and medial offset of the head of the humerus were 2.9° (± 2.3°), 4.0° (± 3.3°), 1.0 mm (± 0.8 mm), 0.8 mm (± 0.6 mm), 0.7 mm (± 0.5 mm) and 1.0 mm (± 0.7 mm), respectively. With the metaphysis excluded, mimicking a fracture of the surgical neck, the errors of prediction for retroversion, inclination, height, radius of curvature and posterior and medial offset of the head of the humerus were 3.8° (± 2.9°), 3.9° (± 3.4°), 2.4 mm (± 1.9 mm), 1.3 mm (± 0.9 mm), 0.8 mm (± 0.5 mm) and 0.9 mm (± 0.6 mm), respectively. Conclusion. This study reports a novel, computerised method that accurately predicts the pre-morbid proximal humeral anatomy even in challenging situations. This information can be used in the surgical planning and operative reconstruction of patients with severe degenerative osteoarthritis or with a fracture of the proximal humerus. Cite this article: Bone Joint J 2017;99-B:927–33


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 780 - 785
1 Jun 2015
Baauw M van Hellemondt GG van Hooff ML Spruit M

We evaluated the accuracy with which a custom-made acetabular component could be positioned at revision arthroplasty of the hip in patients with a Paprosky type 3 acetabular defect. A total of 16 patients with a Paprosky type 3 defect underwent revision surgery using a custom-made trabecular titanium implant. There were four men and 12 women with a median age of 67 years (48 to 79). The planned inclination (INCL), anteversion (AV), rotation and centre of rotation (COR) of the implant were compared with the post-operative position using CT scans. A total of seven implants were malpositioned in one or more parameters: one with respect to INCL, three with respect to AV, four with respect to rotation and five with respect to the COR. To the best of our knowledge, this is the first study in which CT data acquired for the pre-operative planning of a custom-made revision acetabular implant have been compared with CT data on the post-operative position. The results are encouraging. Cite this article: Bone Joint J 2015; 97-B:780–5


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1542 - 1547
1 Nov 2016
Sampath Kumar V Tyrrell PNM Singh J Gregory J Cribb GL Cool P

Aims. The purpose of this study was to determine if clinical and radiological surveillance of cartilage tumours with low biological activity is appropriate. Patients and Methods. A total of 98 patients with an intramedullary cartilage neoplasm in a long bone met our inclusion criteria and were included in the study. These patients had undergone a total of 384 scans. Patients with radiological follow-up of more than three years (46 patients) were divided into two groups: an active group (11 patients) and a latent group (35 patients). Results. Active lesions had a total growth in all three planes that was > 6 mm, whilst latent lesions had < 6 mm of growth. Most latent lesions were heavily calcified: active lesions were calcified less than 50% (p = 0.025). Conclusion. Clinico-radiological surveillance can identify growing cartilage lesions: MRI is the surveillance modality of choice. A CT scan is recommended, in addition, at presentation to assess the amount of calcification within the lesion. A first follow-up MRI is suggested one year from diagnosis. If the total growth in the cartilage lesion is > 6 mm, surgical treatment should be considered. Otherwise, a second surveillance scan can be performed at three years to determine further management. Cite this article: Bone Joint J 2016;98-B:1542–7


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 741 - 748
1 Jun 2015
Bonnin MP Neto CC Aitsiselmi T Murphy CG Bossard N Roche S

The aim of this study was to investigate the relationship between the geometry of the proximal femur and the incidence of intra-operative fracture during uncemented total hip arthroplasty (THA). We studied the pre-operative CT scans of 100 patients undergoing THA with an uncemented femoral component. We measured the anteroposterior and mediolateral dimensions at the level of division of the femoral neck to calculate the aspect ratio of the femur. Wide variations in the shape of the femur were observed, from round, to very narrow elliptic. The femurs of women were narrower than those of men (p < 0.0001) and small femurs were also narrower than large ones. Patients with an intra-operative fracture of the calcar had smaller and narrower femurs than those without a fracture (p < 0.05) and the implanted Corail stems were smaller in those with a fracture (mean size 9 vs 12, p < 0.0001). The variability of the shape of the femoral neck at the level of division contributes to the understanding of the causation of intra-operative fractures in uncemented THA. Cite this article: Bone Joint J 2015;97-B:741–8


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 49 - 57
1 Jan 2016
Bonnin MP Saffarini M Bossard N Dantony E Victor J

Aims. Analysis of the morphology of the distal femur, and by extension of the femoral components in total knee arthroplasty (TKA), has largely been related to the aspect ratio, which represents the width of the femur. Little is known about variations in trapezoidicity (i.e. whether the femur is more rectangular or more trapezoidal). This study aimed to quantify additional morphological characteristics of the distal femur and identify anatomical features associated with higher risks of over- or under-sizing of components in TKA. Methods. We analysed the shape of 114 arthritic knees at the time of primary TKA using the pre-operative CT scans. The aspect ratio and trapezoidicity ratio were quantified, and the post-operative prosthetic overhang was calculated. We compared the morphological characteristics with those of 12 TKA models. Results. There was significant variation in both the aspect ratio and trapezoidicity ratio between individuals. Femoral trapezoidicity was mostly due to an inward curve of the medial cortex. Overhang was correlated with the aspect ratio (with a greater chance of overhang in narrow femurs), trapezoidicity ratio (with a greater chance in trapezoidal femurs), and the tibio-femoral angle (with a greater chance in valgus knees). . Discussion. This study shows that rectangular/trapezoidal variability of the distal femur cannot be ignored. Most of the femoral components which were tested appeared to be excessively rectangular when compared with the bony contours of the distal femur. These findings suggest that the design of TKA should be more concerned with matching the trapezoidal/rectangular shape of the native femur. Take home message: The distal femur is considerably more trapezoidal than most femoral components, and therefore, care must be taken to avoid anterior prosthetic overhang in TKA. Cite this article: Bone Joint J 2016;98-B:49–57


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1111 - 1117
1 Aug 2015
Chiu CK Kwan MK Chan CYW Schaefer C Hansen-Algenstaedt N

We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. Cite this article: Bone Joint J 2015; 97-B:1111–17


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 249 - 253
1 Feb 2014
Euler SA Hengg C Kolp D Wambacher M Kralinger F

Antegrade nailing of proximal humeral fractures using a straight nail can damage the bony insertion of the supraspinatus tendon and may lead to varus failure of the construct. In order to establish the ideal anatomical landmarks for insertion of the nail and their clinical relevance we analysed CT scans of bilateral proximal humeri in 200 patients (mean age 45.1 years (. sd. 19.6; 18 to 97) without humeral fractures. The entry point of the nail was defined by the point of intersection of the anteroposterior and lateral vertical axes with the cortex of the humeral head. The critical point was defined as the intersection of the sagittal axis with the medial limit of the insertion of the supraspinatus tendon on the greater tuberosity. The region of interest, i.e. the biggest entry hole that would not encroach on the insertion of the supraspinatus tendon, was calculated setting a 3 mm minimal distance from the critical point. This identified that 38.5% of the humeral heads were categorised as ‘critical types’, due to morphology in which the predicted offset of the entry point would encroach on the insertion of the supraspinatus tendon that may damage the tendon and reduce the stability of fixation. We therefore emphasise the need for ‘fastidious’ pre-operative planning to minimise this risk. Cite this article: Bone Joint J 2014;96-B:249–53


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1539 - 1545
1 Nov 2015
Lenoir H Chammas M Micallef JP Lazerges C Waitzenegger T Coulet B

Determining and accurately restoring the flexion-extension axis of the elbow is essential for functional recovery after total elbow arthroplasty (TEA). We evaluated the effect of morphological features of the elbow on variations of alignment of the components at TEA. Morphological and positioning variables were compared by systematic CT scans of 22 elbows in 21 patients after TEA. There were five men and 16 women, and the mean age was 63 years (38 to 80). The mean follow-up was 22 months (11 to 44). The anterior offset and version of the humeral components were significantly affected by the anterior angulation of the humerus (p = 0.052 and p = 0.004, respectively). The anterior offset and version of the ulnar components were strongly significantly affected by the anterior angulation of the ulna (p < 0.001 and p < 0.001). The closer the anterior angulation of the ulna was to the joint, the lower the ulnar anterior offset (p = 0.030) and version of the ulnar component (p = 0.010). The distance from the joint to the varus angulation also affected the lateral offset of the ulnar component (p = 0.046). Anatomical variations at the distal humerus and proximal ulna affect the alignment of the components at TEA. This is explained by abutment of the stems of the components and is particularly severe when there are substantial deformities or the deformities are close to the joint. Cite this article: Bone Joint J 2015;97-B:1539–45


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 88 - 96
1 Jan 2016
Tsirikos AI Sud A McGurk SM

Aims. We reviewed 34 consecutive patients (18 female-16 male) with isthmic spondylolysis and grade I to II lumbosacral spondylolisthesis who underwent in situ posterolateral arthodesis between the L5 transverse processes and the sacral ala with the use of iliac crest autograft. Ten patients had an associated scoliosis which required surgical correction at a later stage only in two patients with idiopathic curves unrelated to the spondylolisthesis. . Methods. No patient underwent spinal decompression or instrumentation placement. Mean surgical time was 1.5 hours (1 to 1.8) and intra-operative blood loss 200 ml (150 to 340). There was one wound infection treated with antibiotics but no other complication. Radiological assessment included standing posteroanterior and lateral, Ferguson and lateral flexion/extension views, as well as CT scans. . Results. A solid posterolateral fusion was confirmed in all patients at mean latest follow-up of 4.7 years (3.4 to 9.8) beyond skeletal maturity into early adult life. Fusion of the isthmic lesion was documented in nine patients bilaterally and eight patients unilaterally. The poor fusion rate across the spondylolysis has not affected the excellent functional results of the procedure, which in our series depended on achieving a stable lumbosacral junction. . Conclusion. Quality of life assessment demonstrated significant improvement in all functional scores and high patient satisfaction with 28 patients returning to previous sports activities at an elite competitive level. Take home message: Posterolateral arthrodesis in situ with autologous iliac crest bone without instrumentation has achieved a solid fusion between the L5 transverse processes and the sacral ala in patients with grade I to II isthmic lumbosacral spondylolisthesis and this has produced excellent clinical outcomes and high patient satisfaction. Cite this article: Bone Joint J 2016;98-B:88–96


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 666 - 671
1 May 2016
Makino T Kaito T Sakai Y Kashii M Yoshikawa H

Aims. To clarify the asymmetrical ossification of the epiphyseal ring between the convex and concave sides in patients with adolescent idiopathic scoliosis (AIS). Patients and Methods. A total of 29 female patients (mean age, 14.4 years; 11 to 18) who underwent corrective surgery for AIS (Lenke type 1 or 2) were included in our study. In all, 349 vertebrae including 68 apical vertebrae and 87 end vertebrae in the main thoracic (MT) curve and thoracolumbar/lumbar (TL/L) curve were analysed. Coronal sections (anterior, middle and posterior) of the vertebral bodies were reconstructed from pre-operative CT scans (320-row detector; slice thickness, 0.5 mm) and the appearances of the ossification centre in the epiphyseal ring at four corners were evaluated in three groups; all vertebrae excluding end vertebrae, apical vertebrae and end vertebrae. The appearance rates of the ossification centre at the concave and convex sides were calculated and compared. Results. The appearance rates of the ossification centres in all vertebrae excluding end vertebrae and apical vertebrae were significantly lower on the concave side than on the convex side in both MT and TL/L curves irrespective of curve flexibility. There was no significant difference in the rate of appearance of the ossification centres on the concave or convex sides in end vertebrae. Conclusion. The asymmetric bony growth of vertebral body came into existence at both structural and non-structural curves, and was more apparent around the apical vertebrae. Evaluation of the ossification centre in the epiphyseal ring could be a measure of the effectiveness of brace treatment. Take home message: The ossification of the epiphyseal ring in patients with AIS was delayed or absent on the concave side particularly around the apical vertebrae. Cite this article: Bone Joint J 2016;98-B:666–71


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 212 - 218
1 Feb 2018
Jungbluth P Tanner S Schneppendahl J Grassmann J Wild M Hakimi M Windolf J Laun R

Aims. The aim of this retrospective multicentre study was to evaluate mid-term results of the operative treatment of Monteggia-like lesions and to determine the prognostic factors that influence the clinical and radiological outcome. Patients and Methods. A total of 46 patients (27 women and 19 men), with a mean age of 57.7 years (18 to 84) who had sustained a Monteggia-like lesion were followed up clinically and radiologically after surgical treatment. The Mayo Modified Wrist Score (MMWS), Mayo Elbow Performance Score (MEPS), Broberg and Morrey Score, and Disabilities of the Arm, Shoulder and Hand (DASH) score were used for evaluation at a mean of 65 months (27 to 111) postoperatively. All ulnar fractures were stabilized using a proximally contoured or precontoured locking compression plate. Mason type I fractures of the radial head were treated conservatively, type II fractures were treated with reconstruction, and type III fractures with arthroplasty. All Morrey type II and III fractures of the coronoid process was stabilized using lag screws. Results. Good results were found for the MMWS, with a mean of 88.4 (40 to 100). There were 29 excellent results (63%), nine good (20%), seven satisfactory (15%), and one poor (2%). Excellent results were obtained for the MEPS, with a mean of 90.7 (70 to 100): 31 excellent results (68%), 13 good (28%), and two fair (4%). Good results were also found for the functional rating index of Broberg and Morrey, with a mean score of 86.6 (57 to 100). There were 16 excellent results (35%), 22 good (48%), six fair (13%), and two poor (4%). The mean DASH score was 15.1 (0 to 55.8). Two patients had delayed wound healing; four patients had nonunion requiring bone grafting. One patient had asymptomatic loosening of the radial head prosthesis. Conclusion. Monteggia-like lesions are rare. With correct identification, classification, and understanding using CT scans followed by appropriate surgical treatment that addresses all components of the injury, good to excellent mid-term results can be achieved. Cite this article: Bone Joint J 2018;100-B:212–18


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1242 - 1249
1 Sep 2015
Hintermann B Wagener J Knupp M Schweizer C J. Schaefer D

Large osteochondral lesions (OCLs) of the shoulder of the talus cannot always be treated by traditional osteochondral autograft techniques because of their size, articular geometry and loss of an articular buttress. We hypothesised that they could be treated by transplantation of a vascularised corticoperiosteal graft from the ipsilateral medial femoral condyle. . Between 2004 and 2011, we carried out a prospective study of a consecutive series of 14 patients (five women, nine men; mean age 34.8 years, 20 to 54) who were treated for an OCL with a vascularised bone graft. Clinical outcome was assessed using a visual analogue scale (VAS) for pain and the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score. Radiological follow-up used plain radiographs and CT scans to assess graft incorporation and joint deterioration. . At a mean follow-up of 4.1 years (2 to 7), the mean VAS for pain had decreased from 5.8 (5 to 8) to 1.8 (0 to 4) (p = 0.001) and the mean AOFAS hindfoot score had increased from 65 (41 to 70) to 81 (54 to 92) (p = 0.003). Radiologically, the talar contour had been successfully reconstructed with stable incorporation of the vascularised corticoperiosteal graft in all patients. Joint degeneration was only seen in one ankle. . Treatment of a large OCL of the shoulder of the talus with a vascularised corticoperiosteal graft taken from the medial condyle of the femur was found to be a safe, reliable method of restoring the contour of the talus in the early to mid-term. . Cite this article: Bone Joint J 2015;97-B:1242–9