Advertisement for orthosearch.org.uk
Results 1 - 20 of 1731
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1459 - 1463
1 Nov 2019
Enishi T Yagi H Higuchi T Takeuchi M Sato R Yoshioka S Nakamura M Nakano S

Aims. Rotational acetabular osteotomy (RAO) is an effective joint-preserving surgical treatment for acetabular dysplasia. The purpose of this study was to investigate changes in muscle strength, gait speed, and clinical outcome in the operated hip after RAO over a one-year period using a standard protocol for rehabilitation. Patients and Methods. A total of 57 patients underwent RAO for acetabular dysplasia. Changes in muscle strength of the operated hip, 10 m gait speed, Japanese Orthopaedic Association (JOA) hip score, and factors correlated with hip muscle strength after RAO were retrospectively analyzed. Results. Three months postoperatively, the strength of the operated hip in flexion and abduction and gait speed had decreased from their preoperative levels. After six months, the strength of flexion and abduction had recovered to their preoperative level, as had gait speed. At one-year follow-up, significant improvements were seen in the strength of hip abduction and gait speed, but muscle strength in hip flexion remained at the preoperative level. The mean JOA score for hip function was 91.4 (51 to 100)) at one-year follow-up. Body mass index (BMI) showed a negative correlation with both strength of hip flexion (r = -0.4203) and abduction (r = -0.4589) one year after RAO. Although weak negative correlations were detected between strength of hip flexion one year after surgery and age (r = -0.2755) and centre-edge (CE) angle (r = -0.2989), no correlation was found between the strength of abduction and age and radiological evaluations of CE angle and acetabular roof obliquity (ARO). Conclusion. Hip muscle strength and gait speed had recovered to their preoperative levels six months after RAO. The clinical outcome at one year was excellent, although the strength of hip flexion did not improve to the same degree as that of hip abduction and gait speed. A higher BMI may result in poorer recovery of hip muscle strength after RAO. Radiologically, acetabular coverage did not affect the recovery of hip muscle strength at one year’s follow-up. A more intensive rehabilitation programme may improve this. Cite this article: Bone Joint J 2019;101-B:1459–1463


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 53 - 58
1 Jan 2019
Billi F Kavanaugh A Schmalzried H Schmalzried TP

Aims. Loosening of the tibial component after total knee arthroplasty (TKA) is a common indication for revision. Increasing the strength of the initial tibial implant/cement interface is desirable. There is little information about the surgical techniques that lead to the highest strength. We investigated the effects of eight variables on the strength of the initial tibial baseplate/cement interface. Materials and Methods. A total of 48 tibial trays were cemented into acrylic holders using cement from two manufacturers, at three different times (early, normal, and late) using two techniques: cementing the tibial plateau or the plateau and the keel; and involving two conditions of contamination with marrow fat (at the metal/cement and cement/cement interfaces). Push-out tests were performed with load continuously recorded. Results. Compared with normal conditions, early cementing increased the mean strength of the interface when using the two cements, Simplex and Palacos, by 48% and 72%, respectively. Late cementing reduced the strength by 47% and 73%, respectively. Cementing the keel increased the mean strength by 153% and 147%, respectively, for the two cements. Contamination of the metal/cement interface with fat reduced the mean strength by 99% and 94% for the two cements but adding cement to the underside of the tibial tray prior to insertion resulted in the mean strength being lowered by only 65% and 43%, respectively. Conclusion. In order to maximize the strength of the tibial tray/cement interface, cement should be applied to the component soon after mixing, contamination of the interface should be avoided, and the keel and the plateau should be cemented


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 84 - 90
1 Jul 2019
Jennings JM Loyd BJ Miner TM Yang CC Stevens-Lapsley J Dennis DA

Aims. The aim of this study was to determine whether closed suction drain (CSD) use influences recovery of quadriceps strength and to examine the effects of drain use on secondary outcomes: quadriceps activation, intra-articular effusion, bioelectrical measure of swelling, range of movement (ROM), pain, and wound healing complications. Patients and Methods. A total of 29 patients undergoing simultaneous bilateral total knee arthroplasty (TKA) were enrolled in a prospective, randomized blinded study. Patients were randomized to receive a CSD in one limb while the contralateral limb had the use of a subcutaneous drain (SCDRN) without the use of suction (‘sham drain’). Isometric quadriceps strength was collected as the primary outcome. Secondary outcomes consisted of quadriceps activation, intra-articular effusion measured via ultrasound, lower limb swelling measured with bioelectrical impendence and limb girth, knee ROM, and pain. Outcomes were assessed preoperatively and postoperatively at day two, two and six weeks, and three months. Differences between limbs were determined using paired Student’s t-tests or Wilcoxon’s signed-rank tests. Results. No significant differences were identified between limbs prior to surgery for the primary or secondary outcomes. No significant differences in quadriceps strength were seen between CSD and SCDRN limbs at postoperative day two (p = 0.09), two weeks (primary endpoint) (p = 0.7), six weeks (p = 0.3), or three months (p = 0.5). The secondary outcome of knee extension ROM was significantly greater in the CSD limb compared with the SCDRN (p = 0.01) at two weeks following surgery, but this difference was absent at all other intervals. Secondary outcomes of quadriceps activation, intra-articular effusion, lower limb swelling, and pain were not found to differ significantly at any timepoint following surgery. Conclusion. The use of CSD during TKA did not influence quadriceps strength, quadriceps activation, intra-articular effusion, lower limb swelling, ROM, or pain. These results have limited drain use by the authors in primary uncomplicated TKA. Cite this article: Bone Joint J 2019;101-B (7 Supple C):84–90


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 473 - 477
1 Apr 2015
Bone MC Dold P Flohr M Preuss R Joyce TJ Aspden RM Holland J Deehan D

Concerns have been raised that deformation of acetabular shells may disrupt the assembly process of modular prostheses. In this study we aimed to examine the effect that the strength of bone has on the amount of deformation of the acetabular shell. The hypothesis was that stronger bone would result in greater deformation. A total of 17 acetabular shells were inserted into the acetabula of eight cadavers, and deformation was measured using an optical measuring system. Cores of bone from the femoral head were taken from each cadaver and compressed using a materials testing machine. The highest peak modulus and yield stress for each cadaver were used to represent the strength of the bone and compared with the values for the deformation and the surgeon’s subjective assessment of the hardness of the bone. The mean deformation of the shell was 129 µm (3 to 340). No correlation was found between deformation and either the maximum peak modulus (r² = 0.011, t = 0.426, p = 0.676) or the yield stress (r² = 0.024, t = 0.614, p = 0.549) of the bone. Although no correlation was found between the strength of the bone and deformation, the values for the deformation observed could be sufficient to disrupt the assembly process of modular acetabular components. Cite this article: Bone Joint J 2015; 97-B:473–7


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 902 - 906
1 Jul 2014
Chareancholvanich K Pornrattanamaneewong C

We have compared the time to recovery of isokinetic quadriceps strength after total knee replacement (TKR) using three different lengths of incision in the quadriceps. We prospectively randomised 60 patients into one of the three groups according to the length of incision in the quadriceps above the upper border of the patella (2 cm, 4 cm or 6 cm). The strength of the knees was measured pre-operatively and every month post-operatively until the peak quadriceps torque returned to its pre-operative level. There was no significant difference in the mean operating time, blood loss, hospital stay, alignment or pre-operative isokinetic quadriceps strength between the three groups. Using the Kaplan–Meier method, group A had a similar mean recovery time to group B (2.0 ± 0.2 vs 2.5 ± 0.2 months, p = 0.176). Group C required a significantly longer recovery time (3.4 ± 0.3 months) than the other groups (p < 0.03). However, there were no significant differences in the mean Oxford knee scores one year post-operatively between the groups. We conclude that an incision of up to 4 cm in the quadriceps does not delay the recovery of its isokinetic strength after TKR. Cite this article: Bone Joint J 2014;96-B:902–6


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1524 - 1532
1 Nov 2018
Angélico ACC Garcia LM Icuma TR Herrero CF Maranho DA

Aims. The aims of this study were to evaluate the abductor function in moderate and severe slipped capital femoral epiphysis (SCFE), comparing the results of a corrective osteotomy at the base of the femoral neck and osteoplasty with 1) in situ epiphysiodesis for mild SCFE, 2) contralateral unaffected hips, and 3) hips from healthy individuals. Patients and Methods. A total of 24 patients (mean age 14.9 years (. sd. 1.6); 17 male and seven female patients) with moderate or severe SCFE (28 hips) underwent base of neck osteotomy and osteoplasty between 2012 and 2015. In situ epiphysiodesis was performed in seven contralateral hips with mild slip. A control cohort was composed of 15 healthy individuals (mean age 16.5 years (. sd. 2.5); six male and nine female patients). The abductor function was assessed using isokinetic dynamometry and range of abduction, with a minimum one-year follow-up. Results. We found no differences in mean peak abductor torque between the hips that underwent osteotomy and those that received in situ epiphysiodesis (p = 0.63), but the torque was inferior in comparison with contralateral hips without a slip (p < 0.01) and hips from control individuals (p < 0.001). The abduction strength was positively correlated with the range of hip abduction (R = 0.36; p < 0.001). Conclusion. Although the abductor strength was not restored to normal levels, moderate and severe SCFE treated with osteotomy at the base of the femoral neck and osteoplasty showed abductor function similar to in situ epiphysiodesis in hips with less severe displacement. Cite this article: Bone Joint J 2018;100-B:1524–32


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1508 - 1513
1 Nov 2013
Ploegmakers JJW The B Brutty M Ackland TR Wang AW

The aim of this study was to determine the effect of a Galeazzi fracture on the strength of pronation and supination at a mean of two years after surgical treatment. The strength of pronation and supination was measured in varying rotational positions of the forearm of ten male patients (mean age 38.9 years (21 to 64)) who had undergone plate fixation for a Galeazzi fracture. The stability of the distal radioulnar joint was assessed, and a clinical assessment using the quick-Disabilities of the Arm Shoulder and Hand (quickDASH) questionnaire and patient-related wrist examination (PRWE) scores was undertaken. In addition, the strength of pronation and supination was measured in a male control group of 42 healthy volunteers (mean age 21.8 years (18 to 37)). . The mean absolute loss of strength of supination in the injured compared with the non-injured arm throughout all ranges of forearm rotation was 16.1 kg (. sem. 5.3), corresponding to a relative loss of 12.5% (95% confidence interval (CI) 3.6 to 21.4). For the strength of pronation, the mean loss was 19.1 kg (. sem. 4.5), corresponding to a relative loss of 27.2% (95% CI 14.2 to 40.1). Loss of strength of supination following a Galeazzi fracture correlated with poor quickDASH (p = 0.03) and PRWE scores (p < 0.01). Loss of strength of pronation (27.2%), and of supination (12.5%) in particular, after a Galeazzi fracture is associated with worse clinical scores, highlighting the importance of supination of the forearm in function of the upper limb. Cite this article: Bone Joint J 2013;95-B:1508–13


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 36 - 40
1 Jan 2005
Mountney J Senavongse W Amis AA Thomas NP

The tensile strength of the medial patellofemoral ligament (MPFL), and of surgical procedures which reconstitute it, are unknown. Ten fresh cadaver knees were prepared by isolating the patella, leaving only the MPFL as its attachment to the medial femoral condyle. The MPFL was either repaired by using a Kessler suture or reconstructed using either bone anchors or one of two tendon grafting techniques. The tensile strength and the displacement to peak force of the MPFL were then measured using an Instron materials-testing machine. The MPFL was found to have a mean tensile strength of 208 N (SD 90) at 26 mm (SD 7) of displacement. The strengths of the other techniques were: sutures alone, 37 N (SD 27); bone anchors plus sutures, 142 N (SD 39); blind-tunnel tendon graft, 126 N (SD 21); and through-tunnel tendon graft, 195 N (SD 66). The last was not significantly weaker than the MPFL itself


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 77 - 82
1 Jan 1997
Itoi E Minagawa H Sato T Sato K Tabata S

We measured the isokinetic strength of abduction, adduction, internal rotation, and external rotation in ten patients with full-thickness tears of the supraspinatus and ten with partial-thickness tears. The measurements were repeated after intra-articular or intrabursal injection of local anaesthetic. Pain blocks produced significant increases in strength in both full and partial-thickness tears. After the block, the strength in full-thickness tears compared with the opposite side was 67% to 81% in abduction and 67% to 78% in external rotation, both significantly smaller than those on the uninvolved side (p = 0.0064, p = 0.0170). In partial-thickness tears the strength after the block ranged from 82% to 111%, with no significant differences between the involved and uninvolved sides. The decreases in strength of 19% to 33% in abduction and 22% to 33% in external rotation after full-thickness tears appear to represent the contribution of supraspinatus to the strength of the shoulder


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 9 - 12
1 Jan 1997
Chehade MJ Pohl AP Pearcy MJ Nawana N

In the assessment of fracture healing by monitoring stiffness with vibrational analysis or instrumented external fixators, it has been assumed that there is a workable correlation between stiffness and strength. We used four-point bending tests to study time-related changes in stiffness and strength in healing tibial fractures in sheep. We aimed to test the validity of the measurement of stiffness to assess fracture strength. At each duration of healing examined, we found marked variations in stiffness and strength. Stiffness was shown to be load-dependent: measurements at higher loads reflected ultimate strength more accurately. There was a biphasic relationship between stiffness and strength: at first there was a strong correlation regardless of loading conditions, but in the second phase, which included the period of ‘clinical healing’, stiffness and strength were not significantly correlated. We conclude that the monitoring of stiffness is useful primarily in assessing progress towards union but is inherently limited as an assessment of strength at the time of clinical union. Any interpretation of stiffness must take into account the load conditions


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 755 - 759
1 Jun 2011
Brennan SA Brabazon D O’Byrne JM

We developed a method of applying vibration to the impaction bone grafting process and assessed its effect on the mechanical properties of the impacted graft. Washed morsellised bovine femoral heads were impacted into shear test rings. A range of frequencies of vibration was tested, as measured using an accelerometer housed in a vibration chamber. Each shear test was repeated at four different normal loads to generate stress-strain curves. The Mohr-Coulomb failure envelope from which shear strength and interlocking values are derived was plotted for each test. The experiments were repeated with the addition of blood in order to replicate a saturated environment. Graft impacted with the addition of vibration at all frequencies showed improved shear strength when compared with impaction without vibration, with 60 Hz giving the largest effect. Under saturated conditions the addition of vibration was detrimental to the shear strength of the aggregate. The civil-engineering principles of particulate settlement and interlocking also apply to impaction bone grafting. Although previous studies have shown that vibration may be beneficial in impaction bone grafting on the femoral side, our study suggests that the same is not true in acetabular revision


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 371 - 380
1 May 1994
Gerber C Schneeberger A Beck M Schlegel U

We have studied the mechanical properties of several current techniques of tendon-to-bone suture employed in rotator-cuff repair. Non-absorbable braided polyester and absorbable polyglactin and polyglycolic acid sutures best combined ultimate tensile strength and stiffness. Polyglyconate and polydioxanone sutures failed only at high loads, but elongated considerably under moderate loads. We then compared the mechanical properties of nine different techniques of tendon grasping, using 159 normal infraspinatus tendons from sheep. The most commonly used simple stitch was mechanically poor: repairs with two or four such stitches failed at 184 N and 208 N respectively. A new modification of the Mason-Allen suture technique improved the ultimate tensile strength to 359 N for two stitches. Finally, we studied the mechanical properties of several methods of anchorage to bone using typically osteoporotic specimens. Single and even double transosseous sutures and suture anchor fixation both failed at low tensile loads (about 140 N). The use of a 2 mm thick, plate-like augmentation device improved the failure strength to 329 N. The mechanical properties of many current repair techniques are poor and can be greatly improved by using good materials, an improved tendon-grasping suture, and augmentation at the bone attachment


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 406 - 407
1 Apr 2003
Savva N McAllen CJP Giddins GEB

In children with obstetric brachial plexus palsy (OBPP) who develop an internal rotation deformity of the shoulder, release of subscapularis improves the range of external rotation of the shoulder and the strength of supination of the forearm. We studied the strength of supination in 35 healthy adult volunteers at 45° of both internal and external rotation. The mean and maximum torques were greater in external than internal rotation by 8.7% and 7.5%, respectively. This was highly significant (p < 0.0001). The increased strength of supination in external rotation is probably because the maximum power of biceps, particularly the long head, may be exerted in this position. In children the difference may be even greater due to anatomical differences causing the dramatic increases in the strength of supination after surgery for OBPP. In adults our findings suggest that the supination exercises which are undertaken after injury or surgery to the forearm or wrist should be performed in external rotation


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 3 | Pages 444 - 450
1 Aug 1949
De V. Weir JB Bell GH Chambers JW

One of the aims of this work was to find criteria by which the quality of bone as a supporting tissue might be judged. This inevitably involves discussion and, if possible, assessment, of the relative importance of the inorganic and organic material of the bone. It is relatively easy to measure the mineral content, and for that reason it has always received more than its due share of attention. In the present experiment the composition of the ash of all bones was remarkably constant, with a Ca/P ratio of 2. Furthermore, X-ray crystallography showed that the structure of the inorganic material was the same in all cases. The great difficulty of measuring variations in the quality of the organic material which is, of course, protein in nature makes it impossible to say how much it influences bone strength. Since at least 40 per cent. of the bone is collagen, either a quantitative or a qualitative alteration might alter bone strength. X-ray crystallography revealed no qualitative differences in the collagen material of bones of the three groups; so that for the present it would seem safer to assume that alterations in the physical properties of the bones are due to variations in the relative proportions of organic and inorganic constituents (Dawson 1946, Bell et al. 1947). These experiments show that the three diets produce highly significant differences in the percentage of ash, in S. B. , and in E. It is possible that some variations in the percentage of ash are due to variations in the absolute collagen (weight of collagen in unit volume of bone substance); but the range of variation in the percentage of ash leaves no reasonable doubt that differences in percentage ash between the diet groups are due essentially to differences in absolute ash. Presumably the collagen contributes something to the strength of the bone; but the indications are that it plays a minor part and that the relative weakness and flexibility of rachitic bones is due to decrease in the absolute ash content. Within any one diet group, the relation between percentage ash and the other two variables, S. B. and E, is masked by other sources of variation such as those associated with the many measurements involved; and thus the correlation between percentage ash and S. B. , and also between percentage ash and E, is not significant. At first sight, the scatter diagrams (Figs. 5 and 6) appear to indicate a correlation between ash and S. B. , and between ash and E. Closer inspection shows, however, that the apparent trend is due largely to differences between the means of the diet groups, and that the points within any one group show no such obvious trend. Figure 7 shows that the position with regard to correlation between S. B. and E is very different. Here there is an obvious trend within each diet group; the amount of scatter is very much less. Calculation shows that, even when the differences between the means of diet groups is excluded, there is still a significant correlation between S. B. and E. The question of the correlation between the three variables is discussed more fully in the addendum to this paper. Although the "goodness" of a bone is usually judged by its breaking stress, the experimental findings recorded above suggest that it may be assessed equally well on the basis of elastic properties as shown by Young's modulus. Normal bones, group S in these experiments, were elastic up to 79 per cent. of their breaking stress (Table II): the poorer bones of groups R and N were, however, only a little inferior in this respect. In some cases there was no apparent deviation of the load-deflexion curve from a straight line until the bone was about to break. Such a curve was published in the first paper of this series (Bell, Cuthbertson and Orr 1941), but in the light of further experience this curve is scarcely typical. The terminal falling over of the curve is illustrated in Figure 4 and is much more marked in the bones of group R. While stress at the upper limit of elasticity varies over a wide range in the three groups (Table II and Fig. 4), the strain at this point is remarkably constant at about 1·5 per cent. This same percentage displacement must occur between the molecules of the bone material at the elastic limit—and it may be that, up to this amount of molecular displacement, the deformation is reversible; but that beyond it, plastic changes occur. We have no evidence as to whether the limiting displacement concerns mineral or protein constituents of the bone, or both. We have already commented on the remarkable strength of bone material (Bell et al., 1941). The breaking stress of normal rat bone is about the same as that of cast iron, and about half that of mild steel. Young's modulus, however, is only one-tenth that of cast iron and one-twentieth that of steel. Thus bone, despite its lightness (specific gravity about 2·5 as compared with 7·9 for iron), is remarkably strong and at the same time more flexible than might be expected. Presumably the biological advantage is that greater flexibility helps to absorb sudden impacts. It is unusual in metallic substances to find the elastic modulus proportional to the strength; this is more characteristic of materials like concrete and timber. Another remarkable property of bone is that it remains elastic up to three-quarters of the breaking stress. Most metals show considerable ductility before reaching their breaking point. While Young's modulus is of interest, both on its own account and as an index of the quality of the bone, its close association with breaking stress suggests that it might be used to predict the maximum load which a bone can carry safely. Since E, unlike S. B. , can be measured without damage, useful information might be gained by measuring the elasticity of living human bones


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 397 - 403
1 May 1988
Amis A

This study aimed to compare the holding strength of various commercially-available anchorage devices for artificial ligaments, so that surgeons might make a reasoned choice. Tensile tests to failure were performed on screws, bollards, toggles and staples which had been implanted into cadaveric bones. The holding strength of all devices correlated significantly with the local thickness of cortical bone, so it is recommended that anchorages should be placed away from the joint line, into diaphyseal bone if possible. A new trans-cortical grommet was developed which, when used around an AO screw, had significantly greater holding strength than the other devices


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 3 | Pages 564 - 570
1 Aug 1970
Bullough PG Munuera L Murphy J Weinstein AM

1. The orientation of collagen fibres of the menisci of the knee has been demonstrated by polarised light microscopy. 2. As might be supposed from its fibre structure, the ultimate tensile strength of the meniscal tissue is dependent upon the axis of loading. 3. The tensile strength of the meniscus is similar to that of articular cartilage


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 217 - 221
1 Mar 1989
Stone M Wilkinson R Stother I

A manufacturing technique to increase the bonding between bone cement and metal prostheses has been assessed in the laboratory by "push-out" tests, and the effects of contamination of the cement and of the prosthesis with blood and intramedullary contents have been studied. The technique, known as pre-coating, increases bond strength; this increase is preserved after contamination of the cement which does, however, cause some lowering of interface shear strength. The implications for clinical practice are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 480 - 484
1 May 1994
Radford W Amis A Heatley F

In an animal model we determined the strength of anterior cruciate ligaments (ACL) after section and repair by four different methods and compared it with that of the intact ligament. The standard suturing technique of multiple loops through the ligament stumps was used. Stronger suture material did not give a stronger repair. Wrapping a fine polyester mesh around the ligament or placing it between the bundles before suture increased the strength of the repair. This modification, allied to protective rehabilitation, may reduce the failure rate of acute ACL repairs


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 320 - 323
1 Mar 1994
Motzkin N Chao E An K Wikenheiser M Lewallen D

We aimed to determine the optimal method of inserting a screw into polymethylmethacrylate (PMMA) cement to enhance fixation. We performed six groups of ten axial pull-out tests with two sizes of screw (3.5 and 4.5 mm AO cortical) and three methods of insertion. Screws were placed into 'fluid' PMMA, into 'solid' PMMA by drilling and tapping, or into 'curing' PMMA with quarter-revolution turns every 30 seconds until the PMMA had hardened. After full hardening, we measured the maximum load to failure for each screw-PMMA construct. We found no significant difference in the pull-out strengths between screw sizes or between screws placed in fluid or solid PMMA. Screws placed in curing PMMA were significantly weaker: the relative strengths of solid, fluid and curing groups were 100%, 97% and 71%, respectively. We recommend the use of either solid or fluid insertion according to the circumstances and the preference of the surgeon


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 865 - 869
1 Nov 1995
McGrory B Morrey B Cahalan T An K Cabanela M

At a minimum of one year after operation, we studied 64 patients with 86 total hip arthroplasties (THA) by standard anteroposterior hip and pelvic radiographs and measurement of range of motion and of isometric abduction strength. The femoral offset correlated positively with the range of abduction (p = 0.046). Abduction strength correlated positively with both femoral offset (p = 0.0001) and the length of the abductor lever arm (p = 0.005). Using multiple regression, abduction strength correlated with height (p = 0.017), gender (p = 0.0005), range of flexion (p = 0.047) and the abductor lever arm (p = 0.060). Our findings suggest that greater femoral offset after THA allows both an increased range of abduction and greater abductor strength