Advertisement for orthosearch.org.uk
Results 1 - 20 of 1072
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 36 - 43
1 Jan 2018
Hambright D Hellman M Barrack R

Aims. The aims of this study were to examine the rate at which the positioning of the acetabular component, leg length discrepancy and femoral offset are outside an acceptable range in total hip arthroplasties (THAs) which either do or do not involve the use of intra-operative digital imaging. Patients and Methods. A retrospective case-control study was undertaken with 50 patients before and 50 patients after the integration of an intra-operative digital imaging system in THA. The demographics of the two groups were comparable for body mass index, age, laterality and the indication for surgery. The digital imaging group had more men than the group without. Surgical data and radiographic parameters, including the inclination and anteversion of the acetabular component, leg length discrepancy, and the difference in femoral offset compared with the contralateral hip were collected and compared, as well as the incidence of altering the position of a component based on the intra-operative image. Results. Digital imaging took a mean of five minutes (2.3 to 14.6) to perform. Intra-operative changes with the use of digital imaging were made for 43 patients (86%), most commonly to adjust leg length and femoral offset. There was a decrease in the incidence of outliers when using intra-operative imaging compared with not using it in regard to leg length discrepancy (20% versus 52%, p = 0.001) and femoral offset inequality (18% versus 44%, p = 0.004). There was also a difference in the incidence of outliers in acetabular inclination (0% versus 7%, p = 0.023) and version (0% versus 4%, p = 0.114) compared with historical results of a high-volume surgeon at the same centre. Conclusion. The use of intra-operative digital imaging in THA improves the accuracy of the positioning of the components at THA without adding a substantial amount of time to the operation. Cite this article: Bone Joint J 2018;100B(1 Supple A):36–43


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 179 - 184
1 Feb 2012
Sutter M Hersche O Leunig M Guggi T Dvorak J Eggspuehler A

Peripheral nerve injury is an uncommon but serious complication of hip surgery that can adversely affect the outcome. Several studies have described the use of electromyography and intra-operative sensory evoked potentials for early warning of nerve injury. We assessed the results of multimodal intra-operative monitoring during complex hip surgery. We retrospectively analysed data collected between 2001 and 2010 from 69 patients who underwent complex hip surgery by a single surgeon using multimodal intra-operative monitoring from a total pool of 7894 patients who underwent hip surgery during this period. In 24 (35%) procedures the surgeon was alerted to a possible lesion to the sciatic and/or femoral nerve. Alerts were observed most frequently during peri-acetabular osteotomy. The surgeon adapted his approach based on interpretation of the neurophysiological changes. From 69 monitored surgical procedures, there was only one true positive case of post-operative nerve injury. There were no false positives or false negatives, and the remaining 68 cases were all true negative. The sensitivity for predicting post-operative nerve injury was 100% and the specificity 100%. We conclude that it is possible and appropriate to use this method during complex hip surgery and it is effective for alerting the surgeon to the possibility of nerve injury


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 699 - 705
1 May 2013
Chin KF Misra VP Sicuri GM Fox M Sinisi M

We investigated the predictive value of intra-operative neurophysiological investigations in obstetric brachial plexus injuries. Between January 2005 and June 2011 a total of 32 infants of 206 referred to our unit underwent exploration of the plexus, including neurolysis. The findings from intra-operative electromyography, sensory evoked potentials across the lesion and gross muscular response to stimulation were evaluated. A total of 22 infants underwent neurolysis alone and ten had microsurgical reconstruction. Of the former, one was lost to follow-up, one had glenoplasty and three had subsequent nerve reconstructions. Of the remaining 17 infants with neurolysis, 13 (76%) achieved a modified Mallet score > 13 at a mean age of 3.5 years (0.75 to 6.25). Subluxation or dislocation of the shoulder is a major confounding factor. The positive predictive value and sensitivity of the intra-operative EMG for C5 were 100% and 85.7%, respectively, in infants without concurrent shoulder pathology. The positive and negative predictive values, sensitivity and specificity of the three investigations combined were 77%, 100%, 100% and 57%, respectively. In all, 20 infants underwent neurolysis alone for C6 and three had reconstruction. All of the former and one of the latter achieved biceps function of Raimondi grade 5. The positive and negative predictive values, sensitivity and specificity of electromyography for C6 were 65%, 71%, 87% and 42%, respectively. Our method is effective in evaluating the prognosis of C5 lesion. Neurolysis is preferred for C6 lesions. Cite this article: Bone Joint J 2013;95-B:699–705


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 43 - 47
1 Jan 2004
Ritter MA Faris PM Thong AE Davis KE Meding JB Berend ME

Interest in unicompartmental knee arthroplasty (UKA) for the treatment of medial compartment osteoarthritis has increased in recent years with apparent improvement in the long-term results. This is a result of improved surgical technique, patient selection, and implant design. In an effort further to improve patient selection we analysed the relationship between the pre-operative alignment of the knee and the anatomical findings at the time of surgery. We compared these findings with the indications for UKA. From 4021 total knee arthroplasties we compared intra-operative observations with the pre-operative clinical data in order to identify knees with isolated, medial, compartment changes, which would have been ideal candidates for UKA. We found that only 247 of the knees (6.1%) met anatomical qualifications for isolated, medial, unicompartmental osteoarthritis, and of these, only 168 (4.3%) met clinical standards ideal for UKA. Pre-operative alignment showed a significant relationship with patterns of disease. Logistic regression revealed a relationship between pre-operative alignment and intra-operative findings resembling a Gaussian distribution. Patients with a pre-operative varus alignment of 7° were slightly more likely to be selected for UKA. But the further the anatomical alignment in either direction varies from 7° of varus, the more unlikely it is for the knee to exhibit a disease pattern of isolated, medial, unicompartmental osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 475 - 480
1 Apr 2009
Matsumoto T Kuroda R Kubo S Muratsu H Mizuno K Kurosaka M

We have developed a new tensor for total knee replacements which is designed to assist with soft-tissue balancing throughout the full range of movement with a reduced patellofemoral joint. Using this tensor in 40 patients with osteoarthritis we compared the intra-operative joint gap in cruciate-retaining and posterior-stabilised total knee replacements at 0°, 10°, 45°, 90° and 135° of flexion, with the patella both everted and reduced. While the measurement of the joint gap with a reduced patella in posterior-stabilised knees increased from extension to flexion, it remained constant for cruciate-retaining joints throughout a full range of movement. The joint gaps at deep knee flexion were significantly smaller for both types of prosthetic knee when the patellofemoral joint was reduced (p < 0.05)


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 643 - 646
1 Aug 1986
Szypryt E Hardy J Colton C

Radiopharmaceuticals have been successfully used to detect occult neoplasms and infective lesions. Bone scans using 99mTc-labelled methylene diphosphonate located osteoid osteomas accurately in a series of 30 symptomatic patients. A portable radiation detector system has been designed to help intra-operative localisation and facilitate complete excision of the lesions with minimal damage to normal tissue. A sodium iodide detector with a fibre-optic link was used at first, but a cadmium telluride system has provided a more durable, reliable and sensitive sterilisable probe


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 364 - 369
1 Mar 2011
Suzuki O Sunagawa T Yokota K Nakashima Y Shinomiya R Nakanishi K Ochi M

The transfer of part of the ulnar nerve to the musculocutaneous nerve, first described by Oberlin, can restore flexion of the elbow following brachial plexus injury. In this study we evaluated the additional benefits and effectiveness of quantitative electrodiagnosis to select a donor fascicle. Eight patients who had undergone transfer of a simple fascicle of the ulnar nerve to the motor branch of the musculocutaneous nerve were evaluated. In two early patients electrodiagnosis had not been used. In the remaining six patients, however, all fascicles of the ulnar nerve were separated and electrodiagnosis was performed after stimulation with a commercially available electromyographic system. In these procedures, recording electrodes were placed in flexor carpi ulnaris and the first dorsal interosseous. A single fascicle in the flexor carpi ulnaris in which a high amplitude had been recorded was selected as a donor and transferred to the musculocutaneous nerve. In the two patients who had not undergone electrodiagnosis, the recovery of biceps proved insufficient for normal use. Conversely, in the six patients in whom quantitative electrodiagnosis was used, elbow flexion recovered to an M4 level. Quantitative intra-operative electrodiagnosis is an effective method of selecting a favourable donor fascicle during the Oberlin procedure. Moreover, fascicles showing a high-amplitude in reading flexor carpi ulnaris are donor nerves that can restore normal elbow flexion without intrinsic loss


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 220 - 226
1 Feb 2006
Krkovič M Kordaš M Tonin M Bošnjak R

Ulnar nerve function, during and after open reduction and internal fixation of fractures of the distal humerus with subperiosteal elevation of the nerve, was assessed by intra-operative neurophysiological monitoring. Intermittent recording of the compound muscle action potentials was taken from the hypothenar muscles in 18 neurologically asymptomatic patients. The mean amplitude of the compound muscle action potential after surgery was 98.1% (. sd. 17.6; −37% to +25%). The amplitude improved in six patients following surgery. Despite unremarkable recordings one patient had progressive paresis. Motor impairment is unlikely if the compound muscle action potential is continuously preserved and not reduced by more than 40% at the end of surgery. Temporary decreases in amplitude by up to 70% were tolerated without clinical consequences. However, repeated clinical examination is obligatory to recognise and treat early post-operative palsy


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 26 - 31
1 Nov 2012
Mayle RE Della Valle CJ

The purpose of this paper is to discuss the risk factors, prevention strategies, classification, and treatment of intra-operative femur fractures sustained during primary and revision total hip arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1207 - 1211
1 Sep 2006
Ashford RU McCarthy SW Scolyer RA Bonar SF Karim RZ Stalley PD

The most appropriate protocol for the biopsy of musculoskeletal tumours is controversial, with some authors advocating CT-guided core biopsy. At our hospital the initial biopsies of most musculoskeletal tumours has been by operative core biopsy with evaluation by frozen section which determines whether diagnostic tissue has been obtained and, if possible, gives the definitive diagnosis. In order to determine the accuracy and cost-effectiveness of this protocol we have undertaken a retrospective audit of biopsies of musculoskeletal tumours performed over a period of two years.

A total of 104 patients had biopsies according to this regime. All gave the diagnosis apart from one minor error which did not alter the management of the patient. There was no requirement for re-biopsy. This protocol was more labour-intensive and 38% more costly than CT-guided core biopsy (AU$1804 vs AU$1308). However, the accuracy and avoidance of the anxiety associated with repeat biopsy outweighed these disadvantages.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1389 - 1394
1 Oct 2011
Soubeyrand M Ciais G Wassermann V Kalouche I Biau D Dumontier C Gagey O

Disruption of the interosseous membrane is easily missed in patients with Essex-Lopresti syndrome. None of the imaging techniques available for diagnosing disruption of the interosseous membrane are completely dependable.

We undertook an investigation to identify whether a simple intra-operative test could be used to diagnose disruption of the interosseous membrane during surgery for fracture of the radial head and to see if the test was reproducible.

We studied 20 cadaveric forearms after excision of the radial head, ten with and ten without disruption of the interosseous membrane. On each forearm, we performed the radius joystick test: moderate lateral traction was applied to the radial neck with the forearm in maximal pronation, to look for lateral displacement of the proximal radius indicating that the interosseous membrane had been disrupted. Each of six surgeons (three junior and three senior) performed the test on two consecutive days.

Intra-observer agreement was 77% (95% confidence interval (CI) 67 to 85) and interobserver agreement was 97% (95% CI 92 to 100). Sensitivity was 100% (95% CI 97 to 100), specificity 88% (95% CI 81 to 93), positive predictive value 90% (95% CI 83 to 94), and negative predictive value 100%).

This cadaveric study suggests that the radius joystick test may be useful for detecting disruption of the interosseous membrane in patients undergoing open surgery for fracture of the radial head and is reproducible. A confirmatory study in vivo is now required.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 277 - 278
1 Feb 2005
KIM WY JARI S


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 526 - 526
1 May 1990
Atar D Grant A Lehman W Strongwater A


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 32 - 33
1 Jan 2007
Konangamparambath S Wilkinson JM Cleveland T Stockley I

Bleeding is a major complication of revision total hip replacement. We report a case where the inflated balloon of a urinary catheter was used to temporarily control intrapelvic bleeding from the superior gluteal artery, while definitive measures for endovascular embolisation were made.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 616 - 622
1 May 2013
Horstmann WG Swierstra MJ Ohanis D Castelein RM Kollen BJ Verheyen CCPM

Autologous retransfusion and no-drainage are both blood-saving measures in total hip replacement (THR). A new combined intra- and post-operative autotransfusion filter system has been developed especially for primary THR, and we conducted a randomised controlled blinded study comparing this with no-drainage.

A total of 204 THR patients were randomised to autologous blood transfusion (ABT) (n = 102) or no-drainage (n = 102). In the ABT group, a mean of 488 ml (sd 252) of blood was retransfused. The mean lowest post-operative haemoglobin level during the hospital stay was higher in the autotransfusion group (10.6 g/dl (7.8 to 13.9) vs 10.2 g/dl (7.5 to 13.3); p = 0.01). The mean haemoglobin levels for the ABT and no-drainage groups were not significantly different on the first day (11.3 g/dl (7.8 to 13.9) vs 11.0 g/dl (8.1 to 13.4); p = 0.07), the second day (11.1 g/dl (8.2 to 13.8) vs 10.8 g/dl (7.5 to 13.3); p = 0.09) or the third day (10.8 g/dl (8.0 to 13.0) vs 10.6 g/dl (7.5 to 14.1); p = 0.15). The mean total peri-operative net blood loss was 1464 ml (sd 505) in the ABT group and 1654 ml (sd 553) in the no-drainage group (p = 0.01). Homologous blood transfusions were needed in four patients (3.9%) in the ABT group and nine (8.8%) in the no-drainage group (p = 0.15). No statistically significant difference in adverse events was found between the groups.

The use of a new intra- and post-operative autologous blood transfusion filter system results in less total blood loss and a smaller maximum decrease in haemoglobin levels than no-drainage following primary THR.

Cite this article: Bone Joint J 2013;95-B:616–22.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1197 - 1198
1 Nov 2004
Burke JG Sher JL

We report the case of a 13-year-old obese child presenting with bilateral stable slipped capital femoral epiphyses, which were managed by percutaneous single screw fixation in situ under image intensifier control using arthrography.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 638 - 641
1 May 2012
Ha C Na S

We aimed to obtain anthropometric data on Korean knees and to compare these with data on commonly available total knee arthroplasties (TKAs). The dimensions of the femora and tibiae of 1168 knees were measured intra-operatively. The femoral components were found to show a tendency toward mediolateral (ML) under-coverage in small femurs and ML overhang in the large femurs. The ML under-coverage was most prominent for the small prostheses. The ML/anteroposterior (ML/AP) ratio of Korean tibiae was greater than that of tibial components.

This study shows that, for different reasons, current TKAs do not provide a reasonable fit for small or large Korean knees, and that the ‘gender-specific’ and ‘stature-specific’ components help for large Korean femurs but offer less satisfactory fits for small femurs. Specific modifications of prostheses are needed for Asian knees.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 716 - 719
1 Nov 1984
Dorgan J Abbott T Bentley G

We used a modification of the wake-up test to monitor spinal cord function in 102 consecutive scoliotic patients undergoing Harrington instrumentation. Four patients were found to have a neural deficit when they were awakened during the operation. Three recovered immediately after partial release of the distracting force; one required immediate removal of the rod and was left with a slight neural deficit. Using our method, we have encountered no problem in performing the wake-up test, although attention is drawn to the difficulty in repeating the test if the patient is re-anaesthetised with diazepam. There were no false negative results in this series.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 133 - 138
1 May 2024
Peuchot H Jacquet C Fabre-Aubrespy M Ferguson D Ollivier M Flecher X Argenson J

Aims. Dual-mobility acetabular components (DMCs) have improved total hip arthroplasty (THA) stability in femoral neck fractures (FNFs). In osteoarthritis, the direct anterior approach (DAA) has been promoted for improving early functional results compared with the posterolateral approach (PLA). The aim of this study was to compare these two approaches in FNF using DMC-THA. Methods. A prospective continuous cohort study was conducted on patients undergoing operation for FNF using DMC by DAA or PLA. Functional outcome was evaluated using the Harris Hip Score (HHS) and Parker score at three months and one year. Perioperative complications were recorded, and radiological component positioning evaluated. Results. There were 50 patients in the DAA group and 54 in the PLA group. The mean HHS was 85.5 (SD 8.8) for the DAA group and 81.8 (SD 11.9) for the PLA group (p = 0.064). In all, 35 patients in the DAA group and 40 in the PLA group returned to their pre-fracture Parker score (p = 0.641) in both groups. No statistically significant differences between groups were found at one year regarding these two scores (p = 0.062 and p = 0.723, respectively). The DAA was associated with more intraoperative complications (p = 0.013). There was one dislocation in each group, and four revisions for DAA and one for PLA, but this difference was not statistically significant. There were also no significant differences regarding blood loss, length of stay, or operating time. Conclusion. In DMC-THA for FNF, DAA did not achieve better functional results than PLA, either at three months or at one year. Moreover, DAA presented an increased risk of intra-operative complications. Cite this article: Bone Joint J 2024;106-B(5 Supple B):133–138


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 468 - 474
1 Apr 2016
Abdel MP Houdek MT Watts CD Lewallen DG Berry DJ

Aims. The goals of this study were to define the risk factors, characteristics, and chronology of fractures in 5417 revision total hip arthroplasties (THAs). . Patients and Methods. From our hospital’s prospectively collected database we identified all patients who had undergone a revision THA between 1969 and 2011 which involved the femoral stem. The patients’ medical records and radiographs were examined and the relevant data extracted. Post-operative periprosthetic fractures were classified using the Vancouver system. A total of 5417 revision THAs were identified. Results. There were 668 intra-operative fractures, giving an incidence of 12%. Fractures were three times more common with uncemented stems (19%) than with cemented stems (6%) (p <  0.001). The incidence of intra-operative femoral fracture varied by uncemented stem type: fully-coated (20%); proximally-coated (19%); modular fluted tapered (16%) (p < 0.05). Most fractures occurred during the insertion of the femoral component (35%). One-third involved the diaphysis and 26% were of the calcar: 69% were undisplaced. There were 281 post-operative fractures of the femur (20-year probability = 11%). There was no difference in risk for cemented and uncemented stems. Post-operative fractures were more common in men < 70 years (p = 0.02). Periprosthetic fractures occurred earlier after uncemented revision of the femoral component, but later after a cemented revision. The most common fracture type was a Vancouver B. 1. (31%). Of all post-operative fractures, 24% underwent open reduction and internal fixation and 15% revision arthroplasty. Conclusion. In revision THA, intra-operative fractures occurred three times more often with an uncemented stem. Many were undisplaced diaphyseal fractures treated with cerclage fixation. . While the risk of post-operative fracture is similar between uncemented and cemented components, they occur at notably different times depending on the type of stem fixation. . Take home message: In revision THA, intra-operative periprosthetic femoral fractures occur three times more often with uncemented stems. Many are non-displaced diaphyseal fractures treated with cerclage fixation. While postoperative fracture risks are equivalent between uncemented and cemented components, they occur at notably different time periods based on stem fixation type. Cite this article: Bone Joint J 2016;98-B:468–74