Advertisement for orthosearch.org.uk
Results 1 - 20 of 498
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 821 - 824
1 Jun 2012
Fushimi K Miyamoto K Fukuta S Hosoe H Masuda T Shimizu K

There have been few reports regarding the efficacy of posterior instrumentation alone as surgical treatment for patients with pyogenic spondylitis, thus avoiding the morbidity of anterior surgery. We report the clinical outcomes of six patients with pyogenic spondylitis treated effectively with a single-stage posterior fusion without anterior debridement at a mean follow-up of 2.8 years (2 to 5). Haematological data, including white cell count and level of C-reactive protein, returned to normal in all patients at a mean of 8.2 weeks (7 to 9) after the posterior fusion. Rigid bony fusion between the infected vertebrae was observed in five patients at a mean of 6.3 months (4.5 to 8) post-operatively, with the remaining patient having partial union. Severe back pain was immediately reduced following surgery and the activities of daily living showed a marked improvement. Methicillin-resistant Staphylococcus aureus was detected as the causative organism in four patients. Single-stage posterior fusion may be effective in patients with pyogenic spondylitis who have relatively minor bony destruction


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 172 - 179
1 Feb 2023
Shimizu T Kato S Demura S Shinmura K Yokogawa N Kurokawa Y Yoshioka K Murakami H Kawahara N Tsuchiya H

Aims. The aim of this study was to investigate the incidence and characteristics of instrumentation failure (IF) after total en bloc spondylectomy (TES), and to analyze risk factors for IF. Methods. The medical records from 136 patients (65 male, 71 female) with a mean age of 52.7 years (14 to 80) who underwent TES were retrospectively reviewed. The mean follow-up period was 101 months (36 to 232). Analyzed factors included incidence of IF, age, sex, BMI, history of chemotherapy or radiotherapy, tumour histology (primary or metastasis; benign or malignant), surgical approach (posterior or combined), tumour location (thoracic or lumbar; junctional or non-junctional), number of resected vertebrae (single or multilevel), anterior resection line (disc-to-disc or intravertebra), type of bone graft (autograft or frozen autograft), cage subsidence (CS), and local alignment (LA). A survival analysis of the instrumentation was performed, and relationships between IF and other factors were investigated using the Cox regression model. Results. A total of 44 patients (32.4%) developed IF at a median of 31 months (interquartile range 23 to 74) following TES. Most IFs were rod fractures preceded by a mean CS of 6.1 mm (2 to 18) and LA kyphotic enhancement of 10.8° (-1 to 36). IF-free survival rates were 75.8% at five years and 56.9% at ten years. The interval from TES to IF peaked at two to three years postoperatively and continued to occur over a period of time thereafter; the early IF-developing group had greater CS at one month postoperatively (CS1M) and more lumbar TES. CS1M ≥ 3 mm and sole use of frozen autografts were identified as independent risk factors for IF. Conclusion. IF is a common complication following TES. We have demonstrated that robust spinal reconstruction preventing CS, and high-quality bone grafting are necessary for successful reconstruction. Cite this article: Bone Joint J 2023;105-B(2):172–179


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 982 - 989
1 Nov 1991
McMaster M

Adolescent idiopathic scoliosis in 152 patients was treated by Luque L-rod instrumentation and early mobilisation without external support. This series was compared with a matched group of 156 patients treated by Harrington instrumentation and immobilised in an underarm jacket for nine months. All the operations in both groups were performed by one surgeon and the patients were followed prospectively for more than two years. Correction of the scoliosis in the frontal plane was similar in both groups. However, the normal sagittal contour was better maintained with Luque rods, especially in the thoracolumbar and lumbar regions, and provided less loss of correction than with Harrington rods. Neither method significantly derotated the scoliosis. All the patients with Luque instrumentation developed a solid fusion despite breakage of the sublaminar wires at one or two levels in 4.9%. There were no major neurological complications with either type of instrumentation


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1067 - 1072
1 Sep 2022
Helenius L Gerdhem P Ahonen M Syvänen J Jalkanen J Charalampidis A Nietosvaara Y Helenius I

Aims. The aim of this study was to evaluate whether, after correction of an adolescent idiopathic scoliosis (AIS), leaving out the subfascial drain gives results that are no worse than using a drain in terms of total blood loss, drop in haemoglobin level, and opioid consumption. Methods. Adolescents (aged between 10 and 21 years) with an idiopathic scoliosis (major curve ≥ 45°) were eligible for inclusion in this randomized controlled noninferiority trial (n = 125). A total of 90 adolescents who had undergone segmental pedicle screw instrumentation were randomized into no-drain or drain groups at the time of wound closure using the sealed envelope technique (1:1). The primary outcome was a drop in the haemoglobin level during first three postoperative days. Secondary outcomes were 48-hour postoperative oxycodone consumption and surgical complications. Results. All 90 patients were included in the primary outcome analysis (no drain = 43; drain = 47). The mean total postoperative blood loss (intraoperative and drain output) was significantly higher in the group with a subfascial drain than in the no-drain group (1,008 ml (SD 520) vs 631 ml (SD 518); p < 0.001). The drop in haemoglobin level did not differ between the study groups over the postoperative timepoints (p = 0.290). The 48-hour opioid consumption was significantly higher in the no-drain group (2.0 mg/kg (SD 0.9) vs 1.4 (SD 0.6); p = 0.005). Two patients in the no-drain and one patient in the drain group developed a surgical site infection. Conclusion. Leaving the subfascial drain out after pedicle screw instrumentation for AIS is not associated with higher postoperative haemoglobin levels. Patients treated without a subfascial drain needed 30% more opioids during the first 48 hours than those who had a drain. Cite this article: Bone Joint J 2022;104-B(9):1067–1072


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 75 - 82
1 Jan 2019
Kim J Lee SY Jung JH Kim SW Oh J Park MS Chang H Kim T

Aims. The aim of this study was to evaluate the outcome of spinal instrumentation in haemodialyzed patients with native pyogenic spondylodiscitis. Spinal instrumentation in these patients can be dangerous due to rates of complications and mortality, and biofilm formation on the instrumentation. Patients and Methods. A total of 134 haemodialyzed patients aged more than 50 years who underwent surgical treatment for pyogenic spondylodiscitis were included in the study. Their mean age was 66.4 years (50 to 83); 66 were male (49.3%) and 68 were female (50.7%). They were divided into two groups according to whether spinal instrumentation was used or not. Propensity score matching was used to attenuate the potential selection bias. The outcome of treatment was compared between these two groups. Results. A total of 89 patients (66.4%) underwent non-instrumented surgery and 45 (33.5%) underwent instrumented surgery. There were no significant differences in the rates of postoperative complications, except for an increased rate of wound problems in the instrumented group, which was found in the unmatched cohorts (p = 0.034). There were no significant differences in the rate of recurrent infections (p = 0.328 for the unmatched cohort; p = 0.269 for the matched cohort) and mortality rate, including in-hospital (p = 0.713 for the unmatched cohort; p = 0.738 for the matched cohort) and one-year rates (p = 0.363 for the unmatched cohort; p = 0.787 for the matched cohort), between the groups. However, the interval between the initial diagnosis and the first recurrence was significantly longer in the instrumented group (p = 0.008 for the unmatched cohort; p = 0.032 for the matched cohort). Conclusion. Instrumented surgery for haemodialyzed patients with pyogenic spondylodiscitis showed similar outcomes, including recurrence and mortality, to non-instrumented surgery, despite the instrumented group having more severe neurological deficit, a larger number of involved levels, and increased kyphotic angle


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1099 - 1105
1 Aug 2016
Weiser L Dreimann M Huber G Sellenschloh K Püschel K Morlock MM Rueger JM Lehmann W

Aims. Loosening of pedicle screws is a major complication of posterior spinal stabilisation, especially in the osteoporotic spine. Our aim was to evaluate the effect of cement augmentation compared with extended dorsal instrumentation on the stability of posterior spinal fixation. Materials and Methods. A total of 12 osteoporotic human cadaveric spines (T11-L3) were randomised by bone mineral density into two groups and instrumented with pedicle screws: group I (SHORT) separated T12 or L2 and group II (EXTENDED) specimen consisting of T11/12 to L2/3. Screws were augmented with cement unilaterally in each vertebra. Fatigue testing was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz) load with stepwise increasing peak force. Results. Augmentation showed no significant increase in the mean cycles to failure and fatigue force (SHORT p = 0.067; EXTENDED p = 0.239). Extending the instrumentation resulted in a significantly increased number of cycles to failure and a significantly higher fatigue force compared with the SHORT instrumentation (EXTENDED non-augmented + 76%, p < 0.001; EXTENDED augmented + 87%, p < 0.001). Conclusion. The stabilising effect of cement augmentation of pedicle screws might not be as beneficial as expected from biomechanical pull-out tests. Lengthening the dorsal instrumentation results in a much higher increase of stability during fatigue testing in the osteoporotic spine compared with cement augmentation. Cite this article: Bone Joint J 2016;98-B:1099–1105


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 565 - 572
1 May 2019
Teeter MG Marsh JD Howard JL Yuan X Vasarhelyi EM McCalden RW Naudie DDR

Aims. The purpose of the present study was to compare patient-specific instrumentation (PSI) and conventional surgical instrumentation (CSI) for total knee arthroplasty (TKA) in terms of early implant migration, alignment, surgical resources, patient outcomes, and costs. . Patients and Methods. The study was a prospective, randomized controlled trial of 50 patients undergoing TKA. There were 25 patients in each of the PSI and CSI groups. There were 12 male patients in the PSI group and seven male patients in the CSI group. The patients had a mean age of 69.0 years (. sd. 8.4) in the PSI group and 69.4 years (. sd. 8.4) in the CSI group. All patients received the same TKA implant. Intraoperative surgical resources and any surgical waste generated were recorded. Patients underwent radiostereometric analysis (RSA) studies to measure femoral and tibial component migration over two years. Outcome measures were recorded pre- and postoperatively. Overall costs were calculated for each group. Results. There were no differences (p > 0.05) in any measurement of migration at two years for either the tibial or femoral components. Movement between one and two years was < 0.2 mm, indicating stable fixation. There were no differences in coronal or sagittal alignment between the two groups. The PSI group took a mean 6.1 minutes longer (p = 0.04) and used a mean 3.4 less trays (p < 0.0001). Total waste generated was similar (10 kg) between the two groups. The PSI group cost a mean CAD$1787 more per case (p < 0.01). Conclusion. RSA criteria suggest that both groups will have revision rates of approximately 3% at five years. The advantages of PSI were minimal or absent for surgical resources used and waste eliminated, and for meeting target alignment, yet had significantly greater costs. Therefore, we conclude that PSI may not offer any advantage over CSI for routine primary TKA cases. Cite this article: Bone Joint J 2019;101-B:565–572


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 56 - 63
1 Jan 2015
Abane L Anract P Boisgard S Descamps S Courpied JP Hamadouche M

In this study we randomised 140 patients who were due to undergo primary total knee arthroplasty (TKA) to have the procedure performed using either patient-specific cutting guides (PSCG) or conventional instrumentation (CI). . The primary outcome measure was the mechanical axis, as measured at three months on a standing long-leg radiograph by the hip–knee–ankle (HKA) angle. This was undertaken by an independent observer who was blinded to the instrumentation. Secondary outcome measures were component positioning, operating time, Knee Society and Oxford knee scores, blood loss and length of hospital stay. A total of 126 patients (67 in the CI group and 59 in the PSCG group) had complete clinical and radiological data. There were 88 females and 52 males with a mean age of 69.3 years (47 to 84) and a mean BMI of 28.6 kg/m. 2. (20.2 to 40.8). The mean HKA angle was 178.9° (172.5 to 183.4) in the CI group and 178.2° (172.4 to 183.4) in the PSCG group (p = 0.34). Outliers were identified in 22 of 67 knees (32.8%) in the CI group and 19 of 59 knees (32.2%) in the PSCG group (p = 0.99). There was no significant difference in the clinical results (p = 0.95 and 0.59, respectively). Operating time, blood loss and length of hospital stay were not significantly reduced (p = 0.09, 0.58 and 0.50, respectively) when using PSCG. . The use of PSCG in primary TKA did not reduce the proportion of outliers as measured by post-operative coronal alignment. . Cite this article: Bone Joint J 2015;97-B:56–63


Aims. Patient-specific instrumentation of total knee arthroplasty (TKA) is a technique permitting the targeting of individual kinematic alignment, but deviation from a neutral mechanical axis may have implications on implant fixation and therefore survivorship. The primary objective of this randomized controlled study was to compare the fixation of tibial components implanted with patient-specific instrumentation targeting kinematic alignment (KA+PSI) versus components placed using computer-assisted surgery targeting neutral mechanical alignment (MA+CAS). Tibial component migration measured by radiostereometric analysis was the primary outcome measure (compared longitudinally between groups and to published acceptable thresholds). Secondary outcome measures were inducible displacement after one year and patient-reported outcome measures (PROMS) over two years. The secondary objective was to assess the relationship between alignment and both tibial component migration and inducible displacement. Patients and Methods. A total of 47 patients due to undergo TKA were randomized to KA+PSI (n = 24) or MA+CAS (n = 23). In the KA+PSI group, there were 16 female and eight male patients with a mean age of 64 years (. sd. 8). In the MA+CAS group, there were 17 female and six male patients with a mean age of 63 years (. sd. 7). Surgery was performed using cemented, cruciate-retaining Triathlon total knees with patellar resurfacing, and patients were followed up for two years. The effect of alignment on tibial component migration and inducible displacement was analyzed irrespective of study group. Results. There was no difference over two years in longitudinal migration of the tibial component between the KA+PSI and MA+CAS groups (reaching median maximum total point motion migration at two years of 0.40 mm for the KA+PSI group and 0.37 mm for the MA+CAS group, p = 0.82; p = 0.68 adjusted for age, sex, and body mass index (BMI) for all follow-ups). Both groups had mean migrations below acceptable thresholds. There was no difference in inducible displacement (p = 0.34) or PROMS (p = 0.61 for the Oxford Knee Score) between groups. There was no correlation between alignment and tibial component migration or alignment and inducible displacement. These findings support non-neutral alignment as a viable option with this component, with no evidence that it compromises fixation. Conclusion. Kinematic alignment using patient-specific instrumentation in TKA was associated with acceptable tibial component migration, indicating stable fixation. These results are supportive of future investigations of kinematic alignment. Cite this article: Bone Joint J 2019;101-B:929–940


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 210 - 214
1 Feb 2007
Lee JS Moon KP Kim SJ Suh KT

There are few reports of the treatment of lumbar tuberculous spondylitis using the posterior approach. Between January 1999 and February 2004, 16 patients underwent posterior lumbar interbody fusion with autogenous iliac-bone grafting and pedicle screw instrumentation. Their mean age at surgery was 51 years (28 to 66). The mean follow-up period was 33 months (24 to 48). The clinical outcome was assessed using the Frankel neurological classification and the Kirkaldy-Willis criteria. On the Frankel classification, one patient improved by two grades (C to E), seven by one grade, and eight showed no change. The Kirkaldy-Willis functional outcome was classified as excellent in eight patients, good in five, fair in two and poor in one. Bony union was achieved within one year in 15 patients. The mean pre-operative lordotic angle was 27.8° (9° to 45°) which improved by the final follow-up to 35.8° (28° to 48°). Post-operative complications occurred in four patients, transient root injury in two, a superficial wound infection in one and a deep wound infection in one, in whom the implant was removed. Our results show that a posterior lumbar interbody fusion with autogenous iliac-bone grafting and pedicle screw instrumentation for tuberculous spondylitis through the posterior approach can give satisfactory results


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 5 | Pages 536 - 541
1 Dec 1982
Hsu L Zucherman J Tang S Leong J

Twenty-eight patients with adolescent idiopathic scoliosis treated by anterior spinal fusion with Dwyer instrumentation were reviewed. The average length of follow-up was 6.9 years. This technique produced better correction of lateral curvature and rotation than Harrington instrumentation, particularly in the thoracolumbar and lumbar region. The length of spine requiring fusion was also shorter. There is, however, a tendency for Dwyer instrumentation to lead to kyphosis. Morbidity was significant and included one case of paraplegia, four cases of deep infection and one case of instrument failure. All of these complications, except one case of deep infection, occurred in patients with curves with an apex above the seventh thoracic vertebra


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1061 - 1065
1 Aug 2010
Cho W Cho SK Wu C

There are three basic concepts that are important to the biomechanics of pedicle screw-based instrumentation. First, the outer diameter of the screw determines pullout strength, while the inner diameter determines fatigue strength. Secondly, when inserting a pedicle screw, the dorsal cortex of the spine should not be violated and the screws on each side should converge and be of good length. Thirdly, fixation can be augmented in cases of severe osteoporosis or revision. A trajectory parallel or caudal to the superior endplate can minimise breakage of the screw from repeated axial loading. Straight insertion of the pedicle screw in the mid-sagittal plane provides the strongest stability. Rotational stability can be improved by adding transverse connectors. The indications for their use include anterior column instability, and the correction of rotational deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 98 - 102
1 Jan 2010
Lattig F Fekete TF Jeszenszky D

Fracture of a pedicle is a rare complication of spinal instrumentation using pedicular screws, but it can lead to instability and pain and may necessitate extension of the fusion. Osteosynthesis of the fractured pedicle by cerclage-wire fixation and augmentation of the screw fixation by vertebroplasty or temporary elongation of the fixation, allows stabilisation without sacrifice of the adjacent healthy segment. We describe three patients who developed a fracture of the pedicle in the most caudal instrumented vertebra early after lumbar spinal fusion. During revision surgery the pedicles were reduced and secured by a soft cerclage wire bilaterally. Fusion was obtained at the site of the primary instrumentation and healing of the pedicles was achieved. Cerclage wiring of the fractured pedicle seems to be safe and avoids permanent extension of the fusion without the sacrifice of an otherwise healthy segment


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1477 - 1481
1 Nov 2008
Jain AK Dhammi IK Prashad B Sinha S Mishra P

Injury to the spinal cord and kyphosis are the two most feared complications of tuberculosis of the spine. Since tuberculosis affects principally the vertebral bodies, anterior decompression is usually recommended. Concomitant posterior instrumentation is indicated to neutralise gross instability from panvertebral disease, to protect the anterior bone graft, to prevent graft-related complications after anterior decompression in long-segment disease and to correct a kyphosis. Two-stage surgery is usually performed in these cases. We present 38 consecutive patients with tuberculosis of the spine for whom anterior decompression, posterior instrumentation, with or without correction of the kyphus, and anterior and posterior fusion was performed in a single stage through an anterolateral extrapleural approach. Their mean age was 20.4 years (2.0 to 57.0). The indications for surgery were panvertebral disease, neurological deficit and severe kyphosis. The patients were operated on in the left lateral position using a ‘T’-shaped incision sited at the apex of kyphosis or lesion. Three ribs were removed in 34 patients and two in four and anterior decompression of the spinal cord was carried out. The posterior vertebral column was shortened to correct the kyphus, if necessary, and was stabilised by a Hartshill rectangle and sublaminar wires. Anterior and posterior bone grafting was performed. The mean number of vertebral bodies affected was 3.24 (2.0 to 9.0). The mean pre-operative kyphosis in patients operated on for correction of the kyphus was 49.08° (30° to 72°) and there was a mean correction of 25° (6° to 42°). All except one patient with a neural deficit recovered complete motor and sensory function. The mean intra-operative blood loss was 1175 ml (800 to 2600), and the mean duration of surgery 3.5 hours (2.7 to 5.0). Wound healing was uneventful in 33 of 38 patients. The mean follow-up was 33 months (11 to 74). None of the patients required intensive care. The extrapleural anterolateral approach provides simultaneous exposure of the anterior and posterior aspects of the spine, thereby allowing decompression of the spinal cord, posterior stabilisation and anterior and posterior bone grafting. This approach has much less morbidity than the two-stage approaches which have been previously described


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1052 - 1061
1 Aug 2014
Thienpont E Schwab PE Fennema P

We conducted a meta-analysis, including randomised controlled trials (RCTs) and cohort studies, to examine the effect of patient-specific instruments (PSI) on radiological outcomes after total knee replacement (TKR) including: mechanical axis alignment and malalignment of the femoral and tibial components in the coronal, sagittal and axial planes, at a threshold of > 3º from neutral. Relative risks (RR) for malalignment were determined for all studies and for RCTs and cohort studies separately. Of 325 studies initially identified, 16 met the eligibility criteria, including eight RCTs and eight cohort studies. There was no significant difference in the likelihood of mechanical axis malalignment with PSI versus conventional TKR across all studies (RR = 0.84, p = 0.304), in the RCTs (RR = 1.14, p = 0.445) or in the cohort studies (RR = 0.70, p = 0.289). The results for the alignment of the tibial component were significantly worse using PSI TKR than conventional TKR in the coronal and sagittal planes (RR = 1.75, p = 0.028; and RR = 1.34, p = 0.019, respectively, on pooled analysis). PSI TKR showed a significant advantage over conventional TKR for alignment of the femoral component in the coronal plane (RR = 0.65, p = 0.028 on pooled analysis), but not in the sagittal plane (RR = 1.12, p = 0.437). Axial alignment of the tibial (p = 0.460) and femoral components (p = 0.127) was not significantly different. We conclude that PSI does not improve the accuracy of alignment of the components in TKR compared with conventional instrumentation. Cite this article: Bone Joint J 2014; 96-B:1052–61


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 670 - 674
1 Jul 1990
Cundy P Paterson D Hillier T Sutherland A Stephen J Foster B

We have studied 34 consecutive patients receiving Cotrel- Dubousset instrumentation for a single and flexible thoracic scoliotic curve, evaluating the rib hump deformity from a single CT scan through the apical vertebra of the curve. Using two measures of rotation we found a mean improvement of 25% in the rotation of the vertebra after operation. Any, usually minor, deterioration occurred in the first six months postoperatively, and there was no significant further deterioration in 19 patients assessed over two years after surgery. Cotrel-Dubousset instrumentation can produce a significant correction of vertebral rotation and of the associated rib hump deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1670 - 1677
1 Dec 2012
Tsirikos AI Subramanian AS

We reviewed 212 consecutive patients with adolescent idiopathic scoliosis who underwent posterior spinal arthrodesis using all pedicle screw instrumentation in terms of clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes. In Group 1 (51 patients), the correction was performed over two rods using bilateral segmental pedicle screws. In Group 2 (161 patients), the correction was performed over one rod using unilateral segmental pedicle screws with the second. rod providing stability of the construct through two-level screw fixation at proximal and distal ends. The mean age at surgery was 14.8 years in both groups. Comparison between groups showed no significant differences with regard to age and Risser grade at surgery, pre- and post-operative scoliosis angle, coronal Cobb correction, length of hospital stay and SRS scores. Correction of upper thoracic curves was significantly better in Group 1 (p = 0.02). Increased surgical time and intra-operative blood loss was recorded in Group 1 (p < 0.001 and p = 0.04, respectively). The implant cost was reduced by mean 35% in Group 2 due to the lesser number of pedicle screws. Unilateral and bilateral pedicle screw techniques have both achieved excellent deformity correction in adolescent patients with idiopathic scoliosis, which was maintained at two-year follow-up. This has been associated with high patient satisfaction and low complication rates


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1342 - 1347
1 Nov 2024
Onafowokan OO Jankowski PP Das A Lafage R Smith JS Shaffrey CI Lafage V Passias PG

Aims

The aim of this study was to investigate the impact of the level of upper instrumented vertebra (UIV) in frail patients undergoing surgery for adult spine deformity (ASD).

Methods

Patients with adult spinal deformity who had undergone T9-to-pelvis fusion were stratified using the ASD-Modified Frailty Index into not frail, frail, and severely frail categories. ASD was defined as at least one of: scoliosis ≥ 20°, sagittal vertical axis (SVA) ≥ 5 cm, or pelvic tilt ≥ 25°. Means comparisons tests were used to assess differences between both groups. Logistic regression analyses were used to analyze associations between frailty categories, UIV, and outcomes.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 20 - 25
1 Jan 1987
McMaster M

Twenty-three patients with severe paralytic thoracolumbar scoliosis due to a myelomeningocele were treated by a two-stage procedure. Before operation the mean scoliosis was 98 degrees: after the first-stage procedure, an anterior spinal fusion and correction with Dwyer instrumentation, this was reduced to a mean of 45 degrees. Approximately two weeks later a posterior spinal fusion with Harrington instrumentation was performed, further reducing the scoliosis to a mean of 29 degrees. The pelvic obliquity also was reduced from a mean of 32 degrees to 6 degrees. Although such management carries risks (one patient died of cardiorespiratory failure after the first stage and one patient was made worse), 21 of the 23 patients had improved posture and function


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 185 - 188
1 Mar 1986
McQueen M Court-Brown C Scott J

A method of stabilising spondylolisthesis using Dwyer instrumentation is described and the results in seven patients are presented. The operation is straightforward, has few complications and also succeeds in reducing the angle of slip