Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 182 - 188
1 Feb 2024
Gallego JA Rotman D Watts AC

Aims

Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm.

Methods

An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 905 - 911
1 Aug 2023
Giannicola G Amura A Sessa P Prigent S Cinotti G

Aims

The aim of this study was to analyze how proximal radial neck resorption (PRNR) starts and progresses radiologically in two types of press-fit radial head arthroplasties (RHAs), and to investigate its clinical relevance.

Methods

A total of 97 patients with RHA were analyzed: 56 received a bipolar RHA (Group 1) while 41 received an anatomical implant (Group 2). Radiographs were performed postoperatively and after three, six, nine, and 12 weeks, six, nine, 12, 18, and 24 months, and annually thereafter. PRNR was measured in all radiographs in the four radial neck quadrants. The Mayo Elbow Performance Score (MEPS), the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH), and the patient-assessed American Shoulder and Elbow Surgeons score - Elbow (pASES-E) were used for the clinical assessment. Radiological signs of implant loosening were investigated.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1620 - 1628
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R

Aims

To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes.

Methods

Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1385 - 1391
1 Oct 2014
Grassmann JP Hakimi M Gehrmann SV Betsch M Kröpil P Wild M Windolf J Jungbluth P

The Essex-Lopresti injury (ELI) of the forearm is a rare and serious condition which is often overlooked, leading to a poor outcome.

The purpose of this retrospective case study was to establish whether early surgery can give good medium-term results.

From a group of 295 patients with a fracture of the radial head, 12 patients were diagnosed with ELI on MRI which confirmed injury to the interosseous membrane (IOM) and ligament (IOL). They were treated by reduction and temporary Kirschner (K)-wire stabilisation of the distal radioulnar joint (DRUJ). In addition, eight patients had a radial head replacement, and two a radial head reconstruction.

All patients were examined clinically and radiologically 59 months (25 to 90) after surgery when the mean Mayo Modified Wrist Score (MMWS) was 88.4 (78 to 94), the mean Mayo Elbow Performance Scores (MEPS) 86.7 (77 to 95) and the mean disabilities of arm, shoulder and hand (DASH) score 20.5 (16 to 31): all of these indicate a good outcome.

In case of a high index of suspicion for ELI in patients with a radial head fracture, we recommend the following: confirmation of IOM and IOL injury with an early MRI scan; early surgery with reduction and temporary K-wire stabilisation of the DRUJ; preservation of the radial head if at all possible or replacement if not, and functional bracing in supination. This will increase the prospect of a good result, and avoid the complications of a missed diagnosis and the difficulties of late treatment.

Cite this article: Bone Joint J 2014;96-B:1385–91.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 151 - 159
1 Feb 2013
Duckworth AD McQueen MM Ring D

Most fractures of the radial head are stable undisplaced or minimally displaced partial fractures without an associated fracture of the elbow or forearm or ligament injury, where stiffness following non-operative management is the primary concern. Displaced unstable fractures of the radial head are usually associated with other fractures or ligament injuries, and restoration of radiocapitellar contact by reconstruction or prosthetic replacement of the fractured head is necessary to prevent subluxation or dislocation of the elbow and forearm. In fractures with three or fewer fragments (two articular fragments and the neck) and little or no metaphyseal comminution, open reduction and internal fixation may give good results. However, fragmented unstable fractures of the radial head are prone to early failure of fixation and nonunion when fixed. Excision of the radial head is associated with good long-term results, but in patients with instability of the elbow or forearm, prosthetic replacement is preferred.

This review considers the characteristics of stable and unstable fractures of the radial head, as well as discussing the debatable aspects of management, in light of the current best evidence.

Cite this article: Bone Joint J 2013;95-B:151–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1389 - 1394
1 Oct 2011
Soubeyrand M Ciais G Wassermann V Kalouche I Biau D Dumontier C Gagey O

Disruption of the interosseous membrane is easily missed in patients with Essex-Lopresti syndrome. None of the imaging techniques available for diagnosing disruption of the interosseous membrane are completely dependable.

We undertook an investigation to identify whether a simple intra-operative test could be used to diagnose disruption of the interosseous membrane during surgery for fracture of the radial head and to see if the test was reproducible.

We studied 20 cadaveric forearms after excision of the radial head, ten with and ten without disruption of the interosseous membrane. On each forearm, we performed the radius joystick test: moderate lateral traction was applied to the radial neck with the forearm in maximal pronation, to look for lateral displacement of the proximal radius indicating that the interosseous membrane had been disrupted. Each of six surgeons (three junior and three senior) performed the test on two consecutive days.

Intra-observer agreement was 77% (95% confidence interval (CI) 67 to 85) and interobserver agreement was 97% (95% CI 92 to 100). Sensitivity was 100% (95% CI 97 to 100), specificity 88% (95% CI 81 to 93), positive predictive value 90% (95% CI 83 to 94), and negative predictive value 100%).

This cadaveric study suggests that the radius joystick test may be useful for detecting disruption of the interosseous membrane in patients undergoing open surgery for fracture of the radial head and is reproducible. A confirmatory study in vivo is now required.


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 2 | Pages 227 - 229
1 May 1976
Dickson R Stein H Bentley G

The results of ten excision arthroplasties of the elbow for rheumatoid disease are described. The operation may afford good relief of pain and a useful increase both of hinge motion and of forearm rotation. Instability is not a serious problem unless the patient has to bear weight on crutches. To increase stability after arthroplasty it appears that Kirschner wire fixation is advisable as well as a plaster cast. For advanced rheumatoid disease unilateral excision arthroplasty has a definite value, especially for patients confined to a wheelchair