Prosthetic joint infection (PJI) remains a major clinical challenge. Neutrophil CD64 index, Fc-gamma receptor 1 (FcγR1), plays an important role in mediating inflammation of bacterial infections and therefore could be a valuable biomarker for PJI. The aim of this study is to compare the neutrophil CD64 index in synovial and blood diagnostic ability with the standard clinical tests for discrimination PJI and aseptic implant failure. A total of 50 patients undergoing revision hip and knee arthroplasty were enrolled into a prospective study. According to Musculoskeletal Infection Society (MSIS) criteria, 25 patients were classified as infected and 25 as not infected. In all patients, neutrophil CD64 index and percentage of polymorphonuclear neutrophils (PMN%) in synovial fluid, serum CRP, ESR, and serum CD64 index levels were measured preoperatively. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were analyzed for each biomarker.Aims
Methods
Aims. Early evidence has emerged suggesting that ceramic-on-ceramic
articulations induce a different tissue reaction to ceramic-on-polyethylene
and metal-on-metal bearings. Therefore, the aim of this study was
to investigate the tissue reaction and cellular response to ceramic
total hip arthroplasty (THA) materials in vitro,
as well as the tissue reaction in capsular tissue after revision
surgery of ceramic-on-ceramic THAs. Patients and Methods. We investigated tissue collected at revision surgery from nine
ceramic-on-ceramic articulations. we compared our findings with
tissue obtained from five metal-on-metal THA revisions, four ceramic-on-polyethylene
THAs, and four primary osteoarthritis synovial membranes. The latter
were analyzed to assess the amount of tissue fibrosis that might
have been present at the time of implantation to enable evaluation,
in relation to implantation time, of any subsequent response in
the tissues. Results. There was a significant increase in tissue fibrosis with implantation
time for all implant types tested. Interestingly, the tissue fibrosis
in ceramic-on-ceramic THAs was significantly increased compared
with metal-on-metal and ceramic-on-polyethylene. Additionally, we
found ceramic wear particles in the periprosthetic tissue of ceramic implants.
Fibroblasts responded with expression of cytokines when cultured
on alumina-toughened zirconia (ATZ) and zirconia-toughened alumina
(ZTA) ceramic surfaces. This response was more pronounced on ATZ
ceramics compared with ZTA ceramics. The same inflammatory response
was observed with
Cytological analysis of material aspirated from the effusion which occasionally develops around a polyglycolic acid (PGA) osteosynthesis implant showed a predominance of inflammatory monocytes and in particular lymphocytes. In order to discover whether PGA implants are immunologically inert, density gradient-isolated