Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 94 - 94
1 Dec 2022
Versteeg A Chisamore N Ng K Elmoursi O Leroux T Zywiel M
Full Access

While surgeon-industry relationships in orthopaedics have a critical role in advancing techniques and patient outcomes, they also present the potential for conflict of interest (COI) and increased risk of bias in surgical education. Consequently, robust processes of disclosure and mitigation of potential COI have been adopted across educational institutions, professional societies, and specialty journals. The past years have seen marked growth in the use of online video-based surgical education platforms that are commonly used by both trainees and practicing surgeons. However, it is unclear to what extent the same COI disclosure and mitigation principles are adhered to on these platforms. Thus, the purpose of the present study was to evaluate the frequency and adequacy of potential COI disclosure on orthopaedic online video-based educational platforms.

We retrospectively reviewed videos from a single, publicly-accessible online peer-to-peer orthopaedic educational video platform (VuMedi) that is used as an educational resource by a large number of orthopaedic trainees across North America. The 25 highest-viewed videos were identified for each of 6 subspecialty areas (hip reconstruction, knee reconstruction, shoulder/elbow, foot and ankle, spine and sports). A standardized case report form was developed based on the COI disclosure guidelines of the American Academy of Orthopaedic Surgery (AAOS) and the Journal of Bone and Joint Surgery. Two reviewers watched and assessed each video for presentation of any identifiable commercial products or brand names, disclosure of funding source for video, and presenter's potential conflict of interest. Additionally, presenter disclosures were cross-referenced against commercial relationships reported in the AAOS disclosure database to determine adequacy of disclosure. Any discrepancies between reviewers were resolved by consensus wherever possible, or with adjudication by a third reviewer when necessary.

Out of 150 reviewed videos, only 37 (25%) included a disclosure statement of any kind. Sixty-nine (46%) videos involved the presentation of a readily identifiable commercial orthopaedic device, implant or brand. Despite this, only 13 of these (19%) included a disclosure of any kind, and only 8 were considered adequate when compared to the presenter's disclosures in the AAOS database. In contrast, 83% of the presenters of the videos included in this study reported one or more commercial relationships in the AAOS disclosure database.

Videos of presentations given at conferences and/or academic meetings had significantly greater rates of disclosure as compared to those that were not (41% vs 14%; p=0.004). Similarly, disclosures associated with conference/meeting presentations had significantly greater rates of adequacy (21% vs 7%; p=0.018). Even so, less than half of the educational videos originating from a conference or meeting included a disclosure of any kind, and only about half of these were deemed adequate. No differences were seen in the rate of disclosures between orthopaedic subspecialties (p=0.791).

Online orthopaedic educational videos commonly involve presentation of specific, identifiable commercial products and brands, and the large majority of presenters have existing financial relationships with potential for conflict of interest. Despite this, the overall rate of disclosure of potential conflict of interest in these educational videos is low, and many of these disclosures are incomplete or inadequate. Further work is needed to better understand the impact of this low rate of disclosure on orthopaedic education both in-training and in practice.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 7 - 7
1 Aug 2020
Melo L Sharma A Stavrakis A Zywiel M Ward S Atrey A Khoshbin A White S Nowak L
Full Access

Total knee arthroplasty (TKA) is the most commonly performed elective orthopaedic procedure. With an increasingly aging population, the number of TKAs performed is expected to be ∼2,900 per 100,000 by 2050. Surgical Site Infections (SSI) after TKA can have significant morbidity and mortality. The purpose of this study was to construct a risk prediction model for acute SSI (classified as either superficial, deep and overall) within 30 days of a TKA based on commonly ordered pre-operative blood markers and using audited administrative data from the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database.

All adult patients undergoing an elective unilateral TKA for osteoarthritis from 2011–2016 were identified from the NSQIP database using Current Procedural Terminology (CPT) codes. Patients with active or chronic, local or systemic infection/sepsis or disseminated cancer were excluded. Multivariate logistic regression was conducted to estimate coefficients, with manual stepwise reduction to construct models. Bootstrap estimation was administered to measure internal validity. The SSI prediction model included the following co-variates: body mass index (BMI) and sex, comorbidities such as congestive heart failure (CHF), chronic obstructive pulmonary disease (COPD), smoking, current/previous steroid use, as well as pre-operative blood markers, albumin, alkaline phosphatase, blood urea nitrogen (BUN), creatinine, hematocrit, international normalized ratio (INR), platelets, prothrombin time (PT), sodium and white blood cell (WBC) levels. To compare clinical models, areas under the receiver operating characteristic (ROC) curves and McFadden's R-squared values were reported.

The total number of patients undergoing TKA were 210,524 with a median age of 67 years (mean age of 66.6 + 9.6 years) and the majority being females (61.9%, N=130,314). A total of 1,674 patients (0.8%) had a SSI within 30 days of the index TKA, of which N=546 patients (33.2%) had a deep SSI and N=1,128 patients (67.4%) had a superficial SSI. The annual incidence rate of overall SSI decreased from 1.60% in 2011 to 0.68% in 2016. The final risk prediction model for SSI contained, smoking (OR=1.69, 95% CI: 1.31 – 2.18), previous/current steroid use (OR=1.66, 95% CI: 1.23 – 2.23), as well as the pre-operative lab markers, albumin (OR=0.46, 95% CI: 0.37 – 0.56), blood urea nitrogen (BUN, OR=1.01, 95% CI: 1 – 1.02), international normalized ratio (INR, OR=1.22, 95% CI:1.05 – 1.41), and sodium levels (OR=0.94, 95% CI: 0.91 – 0.98;). Area under the ROC curve for the final model of overall SSI was 0.64. Models for deep and superficial SSI had ROC areas of 0.68 and 0.63, respectively. Albumin (OR=0.46, 95% CI: 0.37 – 0.56, OR=0.33, 95% CI: 0.27 – 0.40, OR=0.75, 95% CI: 0.59 – 0.95) and sodium levels (OR=0.94, 95% CI: 0.91 – 0.98, OR=0.96, 95% CI: 0.93 – 0.99, OR=0.97, 95% CI: 0.96 – 0.99) levels were consistently significant in all prediction models for superficial, deep and overall SSI, respectively. Overall, hypoalbuminemia and hyponatremia are both significant risk factors for superficial, deep and overall SSI.

To our knowledge, this is the first prediction model for acute SSI post TKA whereby hyponatremia (and hypoalbuminemia) are predictive of SSI. This prediction model can help fill an important gap for predicting risk factors for SSI after TKA and can help physicians better optimize patients prior to TKA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 20 - 20
1 Mar 2013
Zywiel M Syed K Overgaard CB Cheung AC Turgeon T Brandt J
Full Access

Revision of fractured ceramic-on-ceramic total hip replacements with a cobalt-chromium (CoCr) alloy-on-polyethylene articulation can facilitate metallosis and require further expensive revision surgery [1–3]. In the present study, a fifty-two year old male patient suffered from fatal cardiomyopathy after undergoing revision total hip arthroplasty. The patient had received a polyethylene-ceramic acetabular liner and a ceramic femoral head as his primary total hip replacement. The polyethylene-ceramic sandwich acetabular liner fractured in vivo after 58 months and the patient underwent his first revision surgery where he received a Vitamin E stabilized acetabular Polyethylene (PE) liner and a CoCr alloy femoral head with documented synovectomy at that time. After 15 months, the patient was admitted to hospital in cardiogenic shock, with retrieval of the bearing components. Before the second revision surgery, peak serum cobalt levels measured 6,521 μg/L, 78-times greater than serum cobalt levels of 83μg/L associated with cobalt poisoning [4]. Serum titanium levels found in the patient measured 17.5 μg/L) normal, healthy range 0–1.4 μg/L). The retrieved CoCr alloy femoral head had lost a total of 28.3g (24% or an estimated amount of 102 × 10−9 wear particles (∼2 μm diameter) [1]) within 16 months of in vivo service. Despite initiating a cobalt chelating therapy, the patients' cardiac left ventricular ejection fraction remained reduced at 6%. This was followed by multi-organ failure, and ultimately the patient passed away shortly after being taken off life support. Embedded ceramic particles were found on the backside and articular surfaces of the Vitamin E-stabilized PE acetabular liner. Evidence of fretting wear on the titanium (Ti) alloy acetabular shell was present, possibly explaining the increased serum Ti levels. Scanning electron microscopy and energy dispersive X-ray analyses confirmed Ti alloy transfer on the embedded ceramic particles on the backside PE liner surface and CoCr alloy transfer on the embedded ceramic particles on the articular PE liner surface. A fractured ceramic-on-ceramic total hip replacement should not be revised to a CoCr alloy-on-polyethylene articulation irrespective of concurrent synovectomy [5] as it can cause severe, third-body wear to the CoCr alloy femoral head that can lead to metallosis with fatal, systemic consequences.