Modern prostheses of the 3rd and 4th generation facilitate a precise adjustment to various humeral anatomies. This provides major advantages regarding soft tissue balancing and the reconstruction of the rotational center. Thus, high expectations are linked to the use of modern shoulder prostheses compared to conventional designs. Out of a prospective multicenter study, 108 cases (72 females, 36 males) were reviewed. All patients were treated with the same type of double eccentric shoulder prosthesis. The mean age at surgery was 71.5 years (range, 44.6 to 97.3). The Constant Score (CS), ASES Score, X-rays and complications were evaluated at 3, 6, 12 and 24 months as well as 4, 7 and 10 years follow-up.Introduction
Methods
Cementless acetabular fixation has demonstrated superior long-term durability in total hip replacement, but most series have studied implants with porous metal surfaces. We retrospectively evaluated the results of 100 consecutive patients undergoing total hip replacement where a non-porous Allofit component was used for primary press-fit fixation. This implant is titanium alloy, grit-blasted, with a macrostructure of forged teeth and has a biradial shape. A total of 81 patients (82 hips) were evaluated at final follow-up at a mean of 10.1 years (8.9 to 11.9). The Harris Hip Score improved from a mean 53 points (23 to 73) pre-operatively to a mean of 96 points (78 to 100) at final review. The osseointegration of all acetabular components was radiologically evaluated with no evidence of loosening. The survival rate with revision of the component as the endpoint was 97.5% (95% confidence interval 94 to 100) after 11.9 years. Radiolucency was found in one DeLee-Charnley zone in four acetabular components. None of the implants required revision for aseptic loosening. Two patients were treated for infection, one requiring a two-stage revision of the implant. One femoral stem was revised for osteolysis due to the production of metal wear debris, but the acetabular shell did not require revision. This study demonstrates that a non-porous titanium acetabular component with adjunct surface fixation offers an alternative to standard porous-coated implants.
The initial diagnosis was primary coxarthrosis in 63, rheumatoid arthritis in 10, congenital dislocation of the hip in 5 and necrosis of the femoral hed in 3. In all cases the cementless Alloclassic stem was used, as bearing material metasul was implanted in 73 and ceramic-polyethylene in 8 cases.
The preoperative Harris hip score was 53,13 pts (23–73), the postoperative score after 10 years 96,5 (78–100). Radiographic evaluation after 10 years showed no lucencies in 78 of 81 jpints. 3 hips had a lucent line of 1mm in zone III. We detected no signs of osteolysis, loosening or migration. No reoperations for any reason exept 2 septic cases have been performed yet.