header advert
Results 1 - 2 of 2
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 184 - 184
1 Feb 2004
Koulouvaris P Stafilas K Mavrodontidis A Zacharis K Xenakis T
Full Access

We present the results of custom made cementless implants for treatment of osteoarthritis due to congenital disease of hip and osteonecrosis due to other diseases, where the normal anatomy was severely modified and it was impossible to insert the smallest available implant.

There were 43 patients with 52 hips, 6 males – 46 females. The mean age was 48years (22–61). The mean follow-up was 24 months (1–48). There were 32 patients with low dislocation, 14 with high dislocation, 1 with infantile septic arthritis, 1 with Hodgkin disease, 1 with dysplasia, 1 with ankylosing spondylitis, 1 with congenital varus hip and 1 with Perthes disease. Our protocol was consisted of plain radiographs and CT of the acetabulum, femur, knee condylars and foot in order to be evaluated the bone stock of acetabulum and the femur anteversion.

All the patients were evaluated – according to the Merle D’ Aubigne score – two, three and every six months after the operation. There was one complication with a proximal femur fracture in a high dislocated hip during the operation and two complications postoperatively. Both of them were high dislocated hips, and the one had paresis of sciatic nerve, that it recovered. The other had septic loosening and was undertaken revision in two stages. All the patients improved in pain, in walking ability and in range of motion.

The impossibility of using the smallest available implant due to the high deformity and the young age led us to use custom made implant. Although a long follow-up is required for these procedures the first results are very encouraging according to the recovery of the patients which were related to the restoration of hip biomechanics provided by the three dimensional neck orientation.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 184 - 184
1 Feb 2004
Stafilas K Koulouvaris P Mavrodontidis A Zacharis K Mitsionis G Xenakis T
Full Access

Total hip arthroplasty (THA) in neglected congenital dislocation of the hip (CDH) constitutes a challenging procedure, with surgical difficulties and complications. The purpose of this study was to analyse the complications of THAs in CDH.

Between June 1983 and September 2002, 418 THAs were performed in 356 patients with CDH, with a mean follow-up 108 (7–237) months. The mean age at surgery was 53.3 (24–79) years with 325 females and 31 males. 83 patients had CDH in high position. 307 arthroplasties were cementless, 39 cemented and 72 hybrids. 40 stems were custom made. The cup always was positioned at the true acetabulum. 24 shortening osteotomies of the femur, 8 corrective supracondylar and 6 trochanteric osteotomies were performed.

Preoperatively the average Merle d’Aubigne-Postel hip score was 1.1 for pain, 4.8 for range of motion and 3.1 for walking ability. Postoperatively the average hip score was 5.2, 4.7 and 5.3 respectively. The average length discrepancy was 8 cm (3–12) preoperatively and 1.5 cm remained in 8 patients.

Complications included 7 intraoperative fractures of the femur, 12 dislocations, 4 peroneal nerve palsies that recovered, 25 heterotopic ossifications, 7 deep vein thromboses, 3 pulmonary embolisms, early mechanical loosening in 4 cemented and 10 cementless cups and 3 infections. Complications were diminished dramatically last years due to improved surgical technique, new available implants and preoperative evaluation of the hip with CT and CAD-CAM-CAE study that allowed better surgical planning with trial stem implantation from a series of stem designs and custom made femoral components manufacturing.