Advertisement for orthosearch.org.uk
Results 1 - 17 of 17
Results per page:

The management of severe acetabular bone defects poses a complex challenge in revision hip arthroplasty. Although biological fixation materials are currently dominant, cage has played an important role in complex acetabular revision in the past decades, especially when a biological prosthesis is not available. The purpose of this study is to report the long-term clinical and radiographic results of Paprosky type Ⅲ acetabular bone defects revised with cage and morselized allografts.

We retrospectively analyzed 45 patients who underwent revision hip arthroplasty with cage and morselized allografts between January 2007 and January 2019. Forty-three patients were followed up. There were 19 Paprosky type IIIA bone defect patients and 24 Paprosky type IIIB bone defect patients and 7 patients of the 24 were also with pelvic discontinuity. Clinical assessment included Harris Hip Score (HHS) and Short Form-12 (SF-12). Radiographic assessment included cage stability, allografts incorporation, and center of rotation.

All patients were followed up with a mean follow-up of 10.6 years, HHS and SF-12 improved significantly at last follow-up in comparison to the preoperative. There were 2 re-revisions, one at 5 years after surgery, another at 13.6 years after surgery. Two patients had nonprogressive radiolucency in zone III and the junction of zone II and zone III at the bone implant interface. Allografts of 40 (93%) cases incorporated fully.

The combination of cage and morselized allograft is an alternative option for acetabular revision with Paprosky type III bone defects with satisfactory long-term follow-up results.


Aims

Monocyte-lymphocyte ratio (MLR) or neutrophil-lymphocyte ratio (NLR) are useful for diagnosing periprosthetic joint infection (PJI), but their diagnostic values are unclear for screening fixation-related infection (FRI) in patients for whom conversion total hip arthroplasty (THA) is planned after failed internal fixation for femoral neck fracture.

Methods

We retrospectively included 340 patients who underwent conversion THA after internal fixation for femoral neck fracture from January 2008 to September 2020. Those patients constituted two groups: noninfected patients and patients diagnosed with FRI according to the 2013 International Consensus Meeting Criteria. Receiver operating characteristic (ROC) curves were used to determine maximum sensitivity and specificity of these two preoperative ratios. The diagnostic performance of the two ratios combined with preoperative CRP or ESR was also evaluated.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 47 - 47
1 Apr 2019
Luo Z Zhou Z Pei F
Full Access

Object

Although single-radius designs have theoretical advantages in some aspects, there has been a paucity of evaluation studies. The purpose of this study was to compare 10-year clinical, radiological, survivorship outcomes of single radius and multi radius posterior stabilized prosthesis in total knee arthroplasty(TKA) with Rheumatoid Arthritis (RA).

Method

In this retrospective observational study, we reviewed 240 patients (240 knees) with RA who underwent TKA between Oct 2005 and Dec 2007: SR group (120 patients, 120 knees, Stryker Scorpio NRG) and MR group (120 patients, 120 knees, Depuy sigma RP). A 1 : 1 matched case control study was conducted in two groups which were similar in terms of age, gender, BMI, ASA classification and operation team. Mean follow-up periods were 10.73±1.13 (range: 8–13) years and 10.82±1.09 (range: 7–13) years.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1025 - 1032
1 Aug 2018
Wang D Wang H Luo Z Meng W Pei F Li Q Zhou Z Zeng W

Aims

The aim of this study was to identify the most effective regimen of multiple doses of oral tranexamic acid (TXA) in achieving maximum reduction of blood loss in total knee arthroplasty (TKA).

Patients and Methods

In this randomized controlled trial, 200 patients were randomized to receive a single dose of 2.0 g of TXA orally two hours preoperatively (group A), a single dose of TXA followed by 1.0 g orally three hours postoperatively (group B), a single dose of TXA followed by 1.0 g three and nine hours postoperatively (group C), or a single dose of TXA followed by 1.0 g orally three, nine, and 15 hours postoperatively (group D). All patients followed a routine enhanced-recovery protocol. The primary outcome measure was the total blood loss. Secondary outcome measures were hidden blood loss (HBL), reduction in the level of haemoglobin, the rate of transfusion and adverse events.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 3 - 3
1 Jun 2017
Song W Chen L Bergum C Zhou Z Shen M Ren W Yu X Markel D
Full Access

Bone ingrowth is desired with uncemented hip implants. Infection is clearly undesirable. We have worked on developing a nanofiber coating for implants that would enhance bone formation while inhibiting infection. Few studies have focused on developing an implant surface nanofiber (NF) coating to prevent infection and enhance osseointegration by local drug release. In this study, coaxial doxycycline (Doxy)-doped polycaprolactone/polyvinyl alcohol (PCL/PVA) Nanofibers were directly deposited on the titanium (Ti) implant surface during electrospinning.

The interaction of loaded Doxy with both PVA and PCL NFs was characterized by Raman spectroscopy. The bonding strength of Doxy-doped NF coating on Ti implants was confirmed by a stand single-pass scratch test. The improved implant osseointegration by PCL/PVA NF coatings in vivo was confirmed by scanning electron microscopy, histomorphometry and micro computed tomography at 2, 4 and 8 weeks after implantation. The bone contact surface (%) changes of NF coating group (80%) is significantly higher than that of no NF group (< 5%, p<0.05). Finally, we demonstrated that Doxy-doped NF coating effectively inhibited bacterial infection and enhanced osseointegration in an infected (Staphylococcus aureus) tibia implantation rat model. Doxy released from NF coating inhibited bacterial growth up to 8 weeks in vivo. The maximal push-in force of Doxy-NF coating (38 N) is much higher than that of NF coating group (6.5 N) 8 weeks after implantation (p<0.05), which was further confirmed by quantitative histological analysis and micro computed tomography.

These findings indicate that coaxial PCL/PVA NF coating doped with Doxy and/or other drugs have great potential in enhancing implant osseointegration and preventing infection.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 123 - 123
1 Mar 2017
Zhou K Zhou Z Chen Z Wang D Zeng W Pei F
Full Access

Purpose

The aim of this study was to compare the accuracy of limb alignment and component positioning after total knee arthroplasty(TKA) performed using fixed or individual distal femoral valgus correction angle(VCA)in valgus knees.

Materials and Methods

One hundred and twenty-four patients were randomised to undergo TKA with either of the clinical baseline, radiological outcomes and subsequent outcome such as knee HSS scores, knee range of motion (ROM) and visual analogue scale (VAS) scores were assessed. Knees in the individual group (n=62) were performed with a tailored VCA. Knees in the fixed group (n=62) were performed utilizing a 4°VCA.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 124 - 124
1 Mar 2017
Zhou K Zhou Z Chen Z Wang D Pei F
Full Access

Purpose

Recently many authors have questioned the role of tourniquets in primary knee arthroplasty (TKA). Meanwhile, whether the use of an intra-articular wound drainage is an advance over the lack of a drain in TKA is controversial in the literature. This study aimed to investigate the efficacy and safety of drainage or not in TKA without a tourniquet.

Methods

Eighty participants who underwent primary unilateral TKA were prospectively enrolled and were randomized to one of two techniques during surgery without a tourniquet: drainage (Group A) or non-drainage (Group B). Blood loss was monitored perioperatively. The operating time, allogeneic blood transfusion rate, thigh pain, knee pain, limb swelling, clinical outcome as measured by the hospital for special surgery (HSS) score, the ability to straight-leg raise, visual analog scale (VAS) in pain, length of stay and knee active range of motion (ROM) were also recorded. The digital radiographs taken at 6 months postoperatively were assessed for cement mantle thickness and radiolucency using the Knee Society radiographic zones.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 78 - 78
1 Mar 2017
Wang D Zhou Z
Full Access

Purpose

There is controversial whether synovectomy must be done in primary total knee arthroplasty (TKA). The objectivity of the study was to compare the effect of synovectomy on inflammation and clinical outcomes after surgical treatment of knee osteoarthritis.

Methods

A total of 240 patients who underwent primary unilateral TKR were randomly divided into a group without (Group A) and with synovectomy (Group B). All operations were performed by the same surgeon and follow-up was for 4 year. Clinical outcomes (including American Knee Society score (AKS), SF-36, and HSS scores) serum inflammatory markers (including interleukin-6 (IL-6), CRP and ESR) and the difference in temperature of the affected knee skin, swelling, ROM, patients VAS satisfaction score and VAS pain score were sequentially evaluated until 4 years after surgery.


Purpose

Previous studies have demonstrated pronounced reduction of sleep quality following major surgery, which may affect postoperative pain and early recovery. This prospective, randomized, controlled trial was designed to evaluate the effect of zolpidem on sleep quality in fast-track total knee arthroplasty (TKA).

Methods

180 patients who underwent primary TKA were enrolled in this study and randomized 1:1 to receive either zolpidem (Group A) or placebo (Group B) for 6 days. VAS pain scores (rest, ambulation, flexion, and night), range of motion (ROM), opioid analgesics use, postoperative nausea and vomiting (PONV) and other complication, sleep efficacy and patients VAS satisfaction were recorded postoperatively and at 1, 3, 5 after surgery. Sleep quality was measured using the polysomnography (PSG) and Epworth Sleepiness Scale.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 65 - 65
1 Feb 2017
Chen Z Zhou Z Pei F
Full Access

Objective

Compare the safety and effectiveness of different anesthetic technique used in the simultaneous bilateral total knee arthroplasty (BTKA).

Methods

Medical records of patients admitted for simultaneous BTKA between January 1, 2014 and September 1, 2015 in ‘The safety and effect evaluation of joint arthroplasty’ database were analyzed. The general anesthesia (GA) and neuraxial anesthesia (NA) group were identified. Patient preoperative characteristics were compared. Perioperative outcomes measured included operating time, blood loss, transfusion requirement, length of hospitalization, joint range of motion at discharge, complications.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 66 - 66
1 Feb 2017
Chen Z Zhou Z Pei F
Full Access

Objective

To investigate the effectiveness of applying fast track surgery concept in primary total hip arthroplasty.

Methods

The data of patients with primary total hip arthroplasty in our department from January 1, 2013 to October 1, 2015 were retrospectively analyzed. The patients were divided into traditional recovery group, enhanced recoverygroup and update enhanced recovery group according to different interventions. The blood loss, transfusion rate, complications rate, postoperative function, length of stay, hospitalization expense and readmission rate were compared between three groups.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 18 - 18
1 Jan 2017
Wu J Zhou Z Zhao X Xue W Xu J Kirk T
Full Access

The health of a synovial joint is relied on normal function and coordination of a group of tissues such as articular cartilage (AC), ligaments, tendons and muscles. Osteoarthritis (OA), which is the most common joint disease, is clinically characterised by lesion of AC. Despite this, injury of a ligament or tendon or muscle generates a joint instability, which accelerates deterioration of AC and progression of OA. Traditional histology is often used to study the pathology of biological tissues. It requires tissue biopsy, which traumatises the donor tissues. Therefore, it is not an idea method for assessing AC, ligaments and tendons as the tissues have a poor healing capability. There is a worldwide demand of an imaging technique that diagnoses the microstructural changes of chondral and connective tissues without biopsy. Confocal arthroscopy (Optiscan Pty Ltd, Australia) possesses a Ø 6.3 mm probe and offers a 0.7 µm lateral imaging resolution and 7 µm axial resolution. It has been successfully used for examining the internal microstructural disorders in rotator cuff tendons of human cadavers without tissue biopsy (WU et al., 2015). This study investigates the capability of confocal arthroscopy as optical histology for assessing the internal microstructure of AC, ligaments, tendons and muscles in a knee joint.

Four sheep keen joints were freshly donated by other research unrelated to this study. After 5 ml clinical grade fluorescein solution at 0.05 g/L was injected into the joint cavity of a knee joint, the joint was passively exercising for about 10 minutes. The joint was then open collaterally and washed thoroughly using PBS for acquiring the microstructure of AC, ligaments, tendons and muscles using the confocal arthroscopy.

Results: without biopsy, confocal arthroscopy offers an imaging resolution for onsite distinguishing the subtle microstructural difference of AC in the weight-bearing and non-weight bearing region. It also permitted visualising the hierarchical collagen structure in ligaments and tendons at a fibre level, and characterising the muscle nuclei, motor-neurons, moto-neuron synapse and striates of myofibres.

Confocal arthroscopy showed the early promise to act as optical histology for studying the microstructure of chondral and a range of connective tissues, which allows understand better the health status of a knee joint. Since a sheep knee joint is very small for operating a normal procedure of an arthroscopic examination, an open knee joint surgery was performed in this study to allow imaging the microstructure of AC and a range of connective tissues. This is accounted as a limitation in the study. Nevertheless, this study demonstrated the development of confocal arthroscopy may lead to optical histology of the internal microstructure of AC and a group of connective tissues, which offers understanding more comprehensively the healthy status of a knee joint.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 6 - 6
1 Jan 2016
Shi X Zhou Z Pei F
Full Access

Objective

To explore whether good postoperative alignment could be obtained through simple individual valgus resection angle using common instruments in total knee arthroplasty with lateral bowing femur.

Methods

Data of 46 TKAs with lateral bowing femur were collected prospectively, the center of the femoral intercondylar notch was the fixed drilling hole whether preoperative planning or intraoperative implementing. The intramedullary rod was put into the femur as deep as possible, until completely entrance or the distal point of the rod contact with the lateral cortical bone of the femur, which prevent the further entrance of the rod. Individual valgus resection angle ranging from 7°to 9°was performed according to preoperative planning, followed by meticulous assessment of matching between cutting surface and valgus resection angle. Postoperative hip-knee-ankle (HKA) angle?medial tibial plate angle and position of lower extremity alignment passing through the tibial plate were measured.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 370 - 370
1 Mar 2013
Zhou C Zhou Z He J Sun J Shen B Yang J Kang P Pei F
Full Access

Background

Recent anthropometric studies have suggested that current design of total knee arthroplasty (TKA) does not cater to racial anthropometric differences. The purpose of this study was to investigate the exact sizing and rotational landmarks of the distal femur collected and its gender differences from a large group of healthy Southern Chinese using 3D-CT measurements, and then compare these measurements to the five total knee prostheses conventionally used in China.

Methods

This study evaluated distal femoral geometry in 85 healthy Southern Chinese, included 39 females (78 knees) and 46 males (92 knees) with a mean age of 33.9 years,a mean height of 164.7 cm and a mean weight of 59.9 kg. The width of the articular surface as projected onto the transepicondylar line(ML), anteroposterior dimension (AP), the dimensions from medial/lateral epicondyle to posterior condylar (MEP/LEP) were measured. A characterization of the aspect ratio (ML/AP) was made for distal femur. The angles between the tangent line of the posterior condylar surfaces, the Whiteside line, the transepicondylar line, and the trochlear line were measured. The sulcus angle and hip center-femoral shaft angle were also measured [Fig. 1]. The data were compared with the five total knee prostheses conventionally used in China. In analyzing the data, best-fit lines were calculated with use of least-squares regression. The dimensions are summarized as the mean and standard deviation. Comparisons of dimensions between males and females were made with use of the two-sample t test. A p value of <0.05 indicated a significant effect.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 368 - 368
1 Mar 2013
Zeng W Zhou C Zhou Z
Full Access

Background

The purpose of this study was to investigate the morphology characteristic of proximal femur of Chinese people. 170 healthy Southern Chinese hips being measured using 3D computer tomographic, in order to improve prosthesis design and preoperation plan of total hip arthroplasty.

Methods

This study measured proximal femoral geometry in 85 healthy Southern Chinese, included 39 women (78 hips) and 46 men (92 hips) (mean age: 33.9 y, mean height: 164.7 cm, mean weight 59.9 kg). Medullary canal morphology measurements, include: the position of isthmus, medial-lateral(ML) and anteroposterior(AP) medullary canal diameter of isthmus and 20 mm, 10 mm, 0 mm, −20 mm, −160 mm, −200 mm upon less trochanter(LT) (medullary canal height, MCH), canal flare index(CFI), aspect ratio(ML/AP), epiphysis-shaft angel (ES angel) (a posterior bow in the metapysis in lateral view). Exterior morphology measurements include: femoral head offset, ML and UD diameter, femoral head position(FHP) from LT, height of the femoral head center from the tip of the great trochanter(GT)(FHCH), femoral neck and head anteversion angle, femoral neck-shaft angle, neck length, neck width, intertrochanteric length (Fig 1, Fig 2). And then we use student's t–test to compare means, linear regression and correlation to analysis these data's relationship, p value <0.05 indicated a significant effect.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 224 - 224
1 Sep 2012
Zhou Z Zhou C Shen B Yang J Kang P Pei F
Full Access

Background

Recent anthropometric studies have suggested that current design of total knee arthroplasty (TKA) does not cater to racial anthropometric differences. The purpose of this study was to investigate the exact sizing and rotational landmarks of the distal femur collected from a large group of healthy Southern Chinese using three dimensional computer tomographic measurements, and then compare these measurements to the known dimensions from Caucasian populations.

Methods

This study evaluated distal femoral geometry in 125 healthy Southern Chinese, included 58 women (106 knees) and 67 men (134 knees) with a mean age of 35.2±8.11 years, a mean height of 165.5±7.94 cm, and a mean weight of 61.7±9.56 kg. The width of the articular surface as projected onto the transepicondylar line(ML), anteroposterior dimension (AP), the dimensions from medial/lateral epicondyle to posterior condylar (MEP/LEP)were measured. A characterization of the aspect ratio (ML/AP) was made for distal femur[Fig. 1]. The angles between the tangent line of the posterior condylar surfaces, the Whiteside line, the transepicondylar line, and the trochlear line were measured. The sulcus angle and hip center-femoral shaft angle were also measured. Known dimensions from Caucasian populations were compared with the morphologic data collected in this study[Fig. 2]. In analyzing the data, best-fit lines were calculated with use of least-squares regression. The dimensions are summarized as the mean and standard deviation. The differences of rotational landmarks and sizing between the Southern Chinese and Caucasians were assessed with use of the Student t test. A p value of <0.05 indicated a significant effect.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 412 - 412
1 Nov 2011
SHEN B YANG J WANG L ZHOU Z KANG P PEI F
Full Access

Objective: Considering the high incidence and misdiag-nostic rate of developmental dysplasia of hip (DDH) in China, some patients suffer from severe pain in the hip at early age, and a total hip arthroplasty would be necessary. To our knowledge, the intermediate-term(equal to or more than five years) results of total hip arthroplasty (THA) in patients with osteoarthritis secondary to developmental dysplasia of the hip has not been studied in China previously. This study evaluated more than five-year clinical and radiographic outcomes associated with total hip arthroplasty (THA) in a consecutive series of patients with osteoarthritis secondary to developmental dysplasia of the hip.

Methods: From February 2000 to July 2002, 55 patients (69 hips) underwent THA in our hospital were involved in this study. Clinical outcomes were evaluated according to Harris evaluate score. Components migration, periprosthetic bone changes, the polyethylene wear rate were measured radiologically. Kaplan-Meier analysis was performed to evaluate the survival of the acetabular and femoral component. End point was obvious radiological loosening or revision either or both of the acetabular and femoral component for any reason.

Results: Forty-five patients (57 hips) were followed up at least 5 years. The average preoperative Harris hip score was (46.19±18.01) points, which improved to (91.78±3.52) points at final follow-up. There were 48 excellent hips (84.21%), 7 good hips (12.28%), 2 fair hips (3.51%) and no poor hip. There is no significant difference of Harris score between the dysplasia group, the low dislocation group and the high dislocation group (P> 0.05, ANOVA). The mean polyethylene liner wear rate was (0.27±0.14)mm/year. According to the statistical relevant analysis, the wear rate of the polyethylene liner had relationship with the age(r=−0.288, P=0.040), the abnormal abduction angle of the acetabular cup (r=0.317, P=0.023)and the osteolysis rate (r=0.573, P=0.026), while had no significant relationship with the thickness of the polyethylene liner (P=0.326), gender(P=0.097), DDH classification(P=0.958) and the Harris score(P=0.598). There are 5 pelvic osteolysis and 8 proximal femoral osteolysis. Using loosening or revision as the end point for failure, the survival rate of both components was 1.0 (95% confidence interval, 0.98–1.00).

Conclusions: In conclusion, improved surgical technique and design in the components provided favorable mid-term results in Chinese patients with osteoarthritis secondary to developmental dysplasia of the hip. Bulk autogenous or allografting is not needed if more than 70% of the acetabular component is covered by host bone. Although the Asia life style includes more squatting and cross-legged, the results of this series in Chinese population are comparable to the satisfactory results of other reported DDH series whose patients are mainly western people. The mid-term results of THA are equivalent in the group of patients with dysplasia, low dislocation, and high dislocation types both in ace-tabular and femoral components. However, the authors continue to be anxious about the high rate of liner wear and osteolysis, which deserve the necessary long-term follow-up.