Improvements in function after THA can be evaluated using validated health outcome surveys but studies have shown that PROMs are unreliable in following the progress of individuals. Formal gait lab analysis is expensive, time consuming and fixed in terms of location. Inertial Measurement Units (IMUs) containing accelerometers and gyroscopes can determine aspects of gait kinematics in a portable package and can be used in the outpatient setting (Figure 1). In this study multiple metrics describing gait were evaluated pre- and post THA and comparisons made with the normal population The gait of 55 patients with monarthrodial hip arthrosis was measured pre-operatively and at one year post-surgery. Patients with medical co-morbidity or other condition affecting their gait were excluded. Six IMUs aligned in the sagittal plane were attached at the level of the anterior superior iliac spines, mid-thigh and mid-shank. Data was analysed using proprietary software (Figure 2). Each patient underwent a conventional THA using a posterolateral approach. An identical test was performed one year after surgery. 92 healthy individuals with a normal observed gait were used as controls.Introduction
Methods
Mortality following hip arthroplasty is affected by a large number of confounding variables each of which must be considered to enable valid interpretation. The aim of this study was to establish whether it is possible to determine a true cause-and-effect relationship between the risk of mortality and data that are routinely collected by the NJR and to establish the degree to which variation in the mortality rate could be explained by each variable. Relevant variables available from the 2011 NJR data setwere included in a Cox model. We carried out two analyses: Firstly, we conducted an analysis of data collected from the NJR data set used in preparation of the NJR's 8th Annual Report (2011) looking for an association between the variables collected and the risk of mortality. Secondly, as social deprivation is also known to influence mortalityrates but is not routinely collected as part of the NJR data set, a further analysis was performed which included social deprivation data derived from partial postcodes. Mortality rates in hip arthroplasty patients were lower than in the age matched population across all hip types. Age at surgery, ASA grade, diagnosis, gender, provider type, hip type and lead surgeon grade all had a significant effect on mortality. Schemper's statistic showed that only 18.98% of the variation in mortality was explained by the variables available in the NJR data set. It is inappropriate to use Registry data to study an outcome affected by a multitude of confounding variables when these cannot be adequately accounted for in the available data set.
The risk for late periprosthetic fractures is higher in patients treated for a neck of femur fracture compared to those treated for osteoarthritis. It has been hypothesised that osteopenia and consequent decreased stiffness of the proximal femur are responsible for this. We investigated if a femoral component with a bigger body would increase the torque to failure in a biaxially loaded composite sawbone model. A biomechanical composite sawbone model was used. Two different body sizes (Exeter 44-1 vs 44-4) of a polished tapered cemented stem were implanted by an experienced surgeon, in 7 sawbones each and loaded at 40 deg/s internal rotation until failure. Torque to fracture and fracture energy were measured using a biaxial materials testing device (Instron 8874). Data are non-parametric and tested with Mann-Whitney U-test.Introduction:
Method:
In an attempt to reduce stress shielding in the proximal femur multiple new shorter stem design have become available. We investigated the load to fracture of a new polished tapered cemented short stem in comparison to the conventional polished tapered Exeter stem. A total of forty-two stems, twenty-one short stems and twenty-one conventional stems both with three different offsets were cemented in a composite sawbone model and loaded to fracture.Introduction:
Method:
This prospective cohort study investigated whether the use of preoperative anticoagulants is an independent risk factor for the outcomes of surgical treatment of patients with a neck of femur fracture. Data was obtained from a prospectively collected database. All patients admitted for a neck of femur fracture between Nov 2010 and Oct 2011 were included. This resulted in three hundred twenty-eight patients with 330 neck of femur fractures. Four groups were defined; patients preoperatively (i) on aspirin (n = 105); (ii) on clopidogrel (n = 28); (iii) on warfarin (n = 30); and (iv) without any anticoagulation history (n = 167, the control group). The non-warfarin group included the aspirin group, clopidogrel group and the control group. Primary outcome was the in-hospital mortality. Secondary outcomes were the postoperative complications, return to theatre and length of stay.Aim:
Methods:
The design of hip replacements is based on the morphology of the proximal femur. Populations living in hard water regions have higher levels of serum calcium and magnesium which promote bone mineralization. A case control study was performed comparing proximal femoral morphology in patients living in soft and hard water regions to determine whether the effect of water hardness had an implication in the future design of hip-prostheses. The proximal femoral morphology of 2 groups of 70 aged and sex matched patients living in hard and soft water regions at mean age 72.24 (range, 50 to 87 years) were measured using an antero-posterior radiograph of the non-operated hip with magnification adjusted. The medullary canal diameter at the level of the lesser trochanter was significantly wider in patients living in the hard water region (mean width 1.9 mm wider; p=0.003). No difference was found at the isthmus, Dorr index, or cortical bone ratio. In conclusion proximal femoral morphology does differ: a wider medullary canal at the level of the lesser trochanter in hard water regions. This size difference is relatively small and is unlikely therefore to affect the mechanics of the current femoral stem prostheses components.
There has been much discussion and controversy in the media recently regarding metal toxicity following large head metal on metal (MoM) total hip replacement (THR). Patients have been reported as having hugely elevated levels of metal ions with, at times, devastating systemic, neurolgical and/or orthopaedic sequelae. However, no direct correlation between metal ion level and severity of metallosis has yet been defined. Normative levels of metal ions in well functioning, non Cobalt-Chrome hips have also not been defined to date. The Exeter total hip replacement contains no Cobalt-Chrome (Co-Cr) as it is made entirely from stainless steel. However, small levels of these metals may be present in the modular head of the prosthesis, and their effect on metal ion levels in the well functioning patient has not been investigated. We proposed to define the “normal” levels of metal ions detected by blood test in 20 well functioning patients at a minimum 1 year post primary Exeter total hip replacement, where the patient had had only one joint replaced. Presently, accepted normal levels of blood Chromium are 10–100 nmol/L and plasma Cobalt are 0–20 nmol/L. The UK Modern Humanities Research Association (MHRA) has suggested that levels of either Cobalt or Chromium above 7 ppb (equivalent to 135 nmol/L for Chromium and 120 nmol/L for Cobalt) may be significant. Below this level it is indicated that significant soft tissue reaction and tissue damage is less likely and the risk of implant failure is reduced. Hips were a mixture of cemented and hybrid procedures performed by two experienced orthopaedic consultants. Seventy percent were female, with a mixture of head sizes used. In our cohort, there were no cases where the blood Chromium levels were above the normal range, and in more than 70% of cases, levels were below recordable levels. There were also no cases of elevated plasma Cobalt levels, and in 35% of cases, levels were negligible. We conclude that the implantation with an Exeter total hip replacement does not lead to elevation of blood metal ion levels.
Classification systems are used throughout Trauma and Orthopaedic (T&O) surgery, designed to be used for communication, planning treatment options, predicting outcomes and research purposes. As a result the majority of T&O knowledge is based upon such systems with most of the published literature using classifications. Therefore we wanted to investigate the basis for the classification culture in our specialty by reviewing Orthopaedic classifications and the literature to assess whether the classifications had been independently validated. 185 published classification systems within T&O were selected. The original publication for each classification system was reviewed to assess whether any validation process had been performed. Each paper was reviewed to see if any intra-observer or inter-observer error was reported. A PubMed search was then conducted for each classification system to assess whether any independent validation had been performed. Any measurement of validation and error was recorded.Introduction
Methods
We present 346 consecutive revision procedures for aseptic loosening with acetabular impaction bone grafting (AIBG) and a cemented polyethylene cup. Defects were contained with mesh alone. Mean follow up of 6.6 years, range 8 days-13 years. The Oxford Hip (OHS) and Harris Hip (HHS) scores were collected prospectively. Radiological definition of cup failure was either > 5mm displacement, or > 5° rotation. Cox regression analysis was performed on ten separate patient and surgical factors to determine their significance on survivorship. Kaplan Meier survivorship at 10 years (42 cases remaining at risk) for aseptic loosening was 87% (95% confidence Interval (CI): 81.6 to 92.2) and 85.6% (95% CI: 80.3 to 90.9) for all revisions. These results are comparable to other reported series utilising AIBG. However, there were 88 cases (25%) that exceeded the radiological migration parameters, but their functional scores were not significantly different to the non-migrators: OHS p=0.273, HHS p=0.16. The latest post-operative mean OHS was 33 (SD 10.66). Female gender (p=0.039), increasing graft thickness (p=0.006) and the use of mesh (p=0.037) were significant risk factors for revision, but differing techniques in graft preparation, including artificial graft expanders (p=0.73), had no significant effect when analysed using Cox regression.
This study utilised NJR primary hip data from the 6th Annual Report to determine the rate and indication for revision between cemented, uncemented, hybrid and resurfacing prosthetic groups. Regression analysis was performed to identify the influence of gender and ASA grade on these revision rates. Validity of the data was interrogated by exploring for episodes of misclassification. We identified 2,264 misclassified episodes within the four groups (Misclassification rate 2.7% primary, 4.3% revision procedures). Analysis was performed using the “reclassified dataset”. The Kaplan-Meier revision rates at 3 years were 0.9% (95%CI: 0.8%-1.0%) for cemented prostheses, 1.9% (95%CI: 1.8%-2.0%) for uncemented hips, 1.2% (95%CI: 1.0%-1.4%) for hybrids and 3.0%, (95%CI: 2.7%-3.3%) in the resurfacing group. The trends in revision rates were comparable to those published in the NJR (6th Edn.) with significant differences across all groups (p< 0.0001). Revision rates in the under 55 year age group showed an identical hierarchy with cemented and hybrid arthroplasty having the lowest revision rates. Cox Regression analysis indicated that both the prosthesis group in isolation and the interaction between prosthesis group and ASA grade significantly influenced the rate of failure (p< 0.001). Indications for revision showed significant differences in rates for, pain, aseptic loosening, dislocation and malalignment between prosthesis types (p< 0.001). The indications including Aseptic loosening, pain, malalignment and dislocation all demonstrated similar trends in revision rates between prosthetic groups with cemented hips having the lowest rates followed by ascending rates for hybrid, uncemented and resurfacing groups. The exception being dislocation with resurfacings having the lowest revision rates. This study provides important baseline revision rates by indication for each prosthetic group from which future comparisons can be made. Areas of misclassification within the NJR dataset have been reported back for future annual analysis.Results
Discussion