Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 553 - 553
1 Oct 2010
Masud S Batra S Charalambos C Ravenscroft M Sahu A Warren-Smith C
Full Access

Introduction: The Polarus nail is used in the treatment of displaced surgical neck of humerus fractures, but has been reported to have a high hardware complication rate. A recent change to 5.3 mm “non-toggling” proximal locking screws has been introduced in an attempt to minimise these complications.

The aims of this study were to determine union rates and hardware complications, and to assess whether the “non-toggle” proximal locking option prevented screw back-out.

Methods: We performed a retrospective review of case notes and radiographs of consecutive patients treated with the 150 mm length Polarus nail for acute displaced surgical neck of humerus fractures at our unit between 1st May 2002 and 29th February 2008. All patients were followed up until fracture union.

Results: Forty-nine patients were treated with the Polarus nail during the study period. Eleven patients were lost to follow-up before fracture union, so were excluded. Median age of the patients was 72 years (range: 31 to 94 years). Mean time to surgery was 10.7 days (range: two to 25 days).

Thirty-six fractures (95%) went on to unite following treatment with the Polarus nail. Of the two fractures that failed to unite one had an infective non-union and the other developed avascular necrosis with non-union of the surgical neck.

Twelve patients (32%) developed post-operative hardware complications. In nine (24%) there was backing out of the proximal locking screws, but only two patients had symptoms requiring screw removal. In five patients (13%) the nail was prominent proximally, causing impingement. In one patient (3%) the proximal screws penetrated the gleno-humeral joint, although this was asymptomatic.

There was backing-out in six of the 21 patients (29%) in which the standard 5.0 mm proximal locking screws were used. This compared with three out of 14 patients (21%) in which the 5.3 mm “non-toggling” screws were used. The difference in the rate of screw backing-out between the two groups was significant (P = 0.0474, Fisher’s Exact test). In three patients a mixture of 5.0 and 5.3 mm screws was used.

Discussion: The Polarus nail provides a stable fixation to union when used for the treatment of displaced surgical neck of humerus fractures. It is associated with a high hardware complication rate (32%), however, this is asymptomatic in the majority of cases (60%). The 5.3 mm “non-toggle” proximal locking option was found to reduce the rate of screw back-out compared with the standard 5.0 mm screw. We recommend the use of this “non-toggling” screw option for proximal locking.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 499 - 499
1 Aug 2008
Khan WS Jain R Agarwal M Warren-Smith C
Full Access

Introduction: Fractures of the tuberosity heal well irrespective of the treatment instituted. Fractures distal to the tuberosity have a high incidence of delayed union and non-union. This could be due to disruption of the vascular supply that enters the bone at the metaphyseal-diaphyseal region. It has also been reported that in these injuries, stress fractures occur at a different anatomic site that is more distal to acute fractures.

We present one of the largest reported series of such fractures in which we have explored the above statements.

Materials & Methods: A retrospective review of 300 closed fractures of the base of the fifth metatarsal- 268 were tuberosity fractures (group 1) and 32 were fractures distal to the tuberosity (group 2).

The patients were followed up in the outpatients clinic for a mean period of 2 months (group 1) and 16 months (group 2).

The distance of the fracture site from the proximal tip of the metatarsal was measured on the radiographs.

Results:

All group 1 fractures healed well following symptomatic management and none required surgical intervention.

Acute fractures in group 2 did better with non-weight bearing mobilization. Stress related fractures in group 2 took longer to heal when managed non-operatively.

In group 2 patients, the difference in the site of acute & stress fractures was not statistically significant.

No statistically significant correlation between distance from the proximal tip of the fifth metatarsal to the fracture site and union.

Conclusion:

A standardized classification is important because there is great variability in the types of fractures and appropriate treatment.

Nonunion in fractures distal to the tuberosity is not related to the distance of the fracture from the metaphyseal-diaphyseal region

Acute and stress fractures distal to the tuberosity do not occur at different anatomic sites.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 843 - 847
1 Nov 1989
Forster I Warren-Smith C Tew M

We set up a trial to test whether the KT1000 arthrometer would give consistent measurements of anteroposterior laxity when used by the same and different examiners on the knees of the same subjects on the same day. The results showed substantial inter- and intra-examiner variation in the measurements both of absolute displacement in single knees and of side-to-side differences between pairs of knees. This casts doubt on the reliability of the instrument when used to compare the results of different techniques for reconstructing injured cruciate ligaments.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 715 - 718
1 Nov 1987
Warren-Smith C Ward M

The place and effectiveness of surgery for acromioclavicular dislocation is disputed. We have reviewed 29 patients all treated by an operation which holds the clavicle down to the coracoid process. This was effective in both acute and late cases, with rapid return to work, a low incidence of complications and no requirement for secondary procedures. We consider it to be the method of choice when operation is indicated.