Govaers K Philips T Vandekelft A
Full Access

We report on a cadaveric study and early experience using patient specific drill guides to prevent cortex perforations and reduce the need for a trochanteric osteotomy in revision THA.

Mimic software (Materialise) was used for 3D analysis of the cement mantle and cement plug. Based on the CT findings a Cannulated drill guide with the shape of the femoral stem was printed in medical graded nylon intraoperative findings and complications were recorded on videotape using a standard 5mm laparoscope for medullary inspection

Surgical Technique was to attain a pre-operative CT scan with MARS protocol of the proximal femur to evaluate the femoral stem positioning, the 3D anatomy of the cement mantle, the length of the cement plug and the quality of the surrounding bone. Subsequent a 3D printing of patient specific cannulated drill guide with the shape of the removed femoral component but an eccentric cannulation was made.

Endoscopic inspection was performed of the inside of the cement mantle, then insertion of the autoclaved cannulated drill guide in the existing cement mantle. After perforation of the distal plug through the PSI drill guide using either a long drill or an ultrasound plug perforation tool (Zimmer Biomet, Warsaw) the excessive cement was removed with standard available flexible femoral shaft reamers (Zimmer Biomet). Further laproscopic examination of the femoral canal performed to verify completeness of the cement removal

Results

CT scans with 3D reconstruction of the existing cement mantle is possible using Modern CT with MARS protocols. After the training on sawbones and cadaveric bones a predictable plug perforation was obtained in all clinical cases. There were no intraoperative cortex perforations and no intraoperative femoral fractures.

Conclusion

CT scan analysis of femoral cement mantles together with patient specific drill guides are promising tools to reduce the risk of femoral perforation in revision total hip arthroplasty.