Over 8000 total hip arthroplasties (THA) in the UK were revised in 2019, half for aseptic loosening. It is believed that Artificial Intelligence (AI) could identify or predict failing THA and result in early recognition of poorly performing implants and reduce patient suffering. The aim of this study is to investigate whether Artificial Intelligence based machine learning (ML) / Deep Learning (DL) techniques can train an algorithm to identify and/or predict failing uncemented THA. Consent was sought from patients followed up in a single design, uncemented THA implant surveillance study (2010–2021). Oxford hip scores and radiographs were collected at yearly intervals. Radiographs were analysed by 3 observers for presence of markers of implant loosening/failure: periprosthetic lucency, cortical hypertrophy, and pedestal formation. DL using the RGB ResNet 18 model, with images entered chronologically, was trained according to revision status and radiographic features. Data augmentation and cross validation were used to increase the available training data, reduce bias, and improve verification of results. 184 patients consented to inclusion. 6 (3.2%) patients were revised for aseptic loosening. 2097 radiographs were analysed: 21 (11.4%) patients had three radiographic features of failure. 166 patients were used for ML algorithm testing of 3 scenarios to detect those who were revised. 1) The use of revision as an end point was associated with increased variability in accuracy. The area under the curve (AUC) was 23–97%. 2) Using 2/3 radiographic features associated with failure was associated with improved results, AUC: 75–100%. 3) Using 3/3 radiographic features, had less variability, reduced AUC of 73%, but 5/6 patients who had been revised were identified (total 66 identified). The best algorithm identified the greatest number of revised hips (5/6), predicting failure 2–8 years before revision, before all radiographic features were visible and before a significant fall in the Oxford Hip score. True-Positive: 0.77, False Positive: 0.29. ML algorithms can identify failing THA before visible features on radiographs or before PROM scores deteriorate. This is an important finding that could identify failing THA early.
Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common orthopaedic procedures requiring postoperative radiographs to confirm implant positioning and identify complications. Artificial intelligence (AI)-based image analysis has the potential to automate this postoperative surveillance. The aim of this study was to prepare a scoping review to investigate how AI is being used in the analysis of radiographs following THA and TKA, and how accurate these tools are. The Embase, MEDLINE, and PubMed libraries were systematically searched to identify relevant articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews and Arksey and O’Malley framework were followed. Study quality was assessed using a modified Methodological Index for Non-Randomized Studies tool. AI performance was reported using either the area under the curve (AUC) or accuracy.Aims
Methods
There are a wide variety of implant brands and types of knee replacement available to surgeons. With time, the options available within many implant brand portfolios has grown, with alternative tibial or femoral components, tibial insert materials or shapes and patella resurfacings. To investigate the effect of the expansion of implant brand portfolios, and to establish the potential numbers of compatible implant construct combinations.Abstract
Introduction
Aim
Knee arthroplasty surgery is a highly effective treatment for arthritis and disorders of the knee. There are a wide variety of implant brands and types of knee arthroplasty available to surgeons. As a result of a number of highly publicized failures, arthroplasty surgery is highly regulated in the UK and many other countries through national registries, introduced to monitor implant performance, surgeons, and hospitals. With time, the options available within many brand portfolios have grown, with alternative tibial or femoral components, tibial insert materials, or shapes and patella resurfacings. In this study we have investigated the effect of the expansion of implant brand portfolios and where there may be a lack of transparency around a brand name. We also aimed to establish the potential numbers of compatible implant construct combinations. Hypothetical implant brand portfolios were proposed, and the number of compatible implant construct combinations was calculated.Aims
Methods
This study utilized data from the NJR dataset on all Corail/Pinnacle total hip replacements (THR) to determine (a) the level of unit variation of the Corail/Pinnacle 36mm Metal On Metal THR within England and Wales; (b) patient, implant and surgeon factors that may be associated with higher revision rates; (c) Account for the influence of the MHRA announcement in 2010. The national Revision Rate (RR) for the Corail / Pinnacle MOM THR was 10.77% (OR:1.46; CI:1.17–1.81). This was significantly greater than other articulation combinations (MOP 1.72%, COP 1.36%, COC 2.19%). The 2010 MHRA announcement did not increase rate of revision (X2=1649.63, df=13, p<.001). Patient factors associated with significantly increased revision rates included, female gender (OR 1.38 (CI 1.17–1.63, p<.001) and younger age OR 0.99 (CI 0.98–0.99), p<.001). Implant factor analysis demonstrated an inverse relationship between cup size and revision. As head length increased RR increased – highest risk of revision +12.5 (OR 1.69 (CI 1.12–2.55), p=0.13). Coxa vara, high offset stems had a higher risk of revision compared to standard offset stems (OR:1.41 (CI 1.15–1.74; p<.001). As stem size increased risk of revision decreased (OR 0.89 (CI 0.85–0.93); p<.001). Surgeon grade did not influence RR. There was significant variation in RR between hospitals with 7 units (7/61 excluding low volume centres, <50 implants) identified as having significant higher rates of revision. However, for each of these units there was a greater proportion of higher risk patients (female, cup size 50–54, stem type). This study has provided insight into unit variation, risk factors and the long term outcome of the Corail/Pinnacle 36mm MOMTHR. Future aims are to use these results to develop a risk stratified algorithm for the long term follow of these patients to minimize patient inconvenience and excess use of limited NHS resources.
Periprosthetic fracture (PF) after primary total hip arthroplasty
(THA) is an uncommon but potentially devastating complication. This
study aims to investigate the influence of cemented stem designs
on the risk of needing a revision for a PF. We analysed data on 257 202 primary THAs with cemented stems
and 390 linked first revisions for PF recorded in the National Joint
Registry (NJR) of England, Wales and Northern Ireland to determine
if a cemented femoral stem brand was associated with the risk of
having revision for a PF after primary THA. All cemented femoral
stem brands with more than 10 000 primary operations recorded in
the NJR were identified. The four most commonly used cemented femoral
stems were the Exeter V40 (n = 146 409), CPT (n = 24 300), C-Stem
(n = 15 113) and Charnley (n = 20 182). We compared the revision risk ratios due to PF amongst the stems
using a Poisson regression model adjusting for patient factors.
Compared with the Exeter V40, the age, gender and ASA grade adjusted
revision rate ratio was 3.89 for the cemented CPT stem (95% confidence
interval (CI) 3.07 to 4.93), 0.89 for the C-Stem (95% CI 0.57 to
1.41) and 0.41 for the Charnley stem (95% CI 0.24 to 0.70).Aims
Patients and Methods
Mix and Match (M&M) describes the use of components from more than one manufacturer in a total hip replacement (THR) The NJR has records of over 90,000 instances where this practice, which is contrary to the advice of most manufacturers and regulators, has been followed. The NJR database 2003–13 was interrogated and the types of M&M were grouped using head size, bearing characteristics and use of cement.Introduction
Patients, Materials and Method
Current analysis of unicondylar knee replacements (UKR) by national registries is based on the pooled results of medial and lateral implants. Using data from the National Joint Registry for England and Wales (NJR) we aimed to determine the proportion of lateral UKR implanted, their survival and reason for failure in comparison to medial UKR. By combining information on the side of operation with component details held on the NJR we were able to determine implant laterality (medial vs. lateral) for 32,847 of the 35,624 (92%) UKR registered before December 2010. Kaplan Meier plots, Life tables and Cox' proportion hazards were used to compare the risk of failure for lateral and medial UKRs after adjustment for patient and implant covariates.Background
Methods
Current analysis of unicondylar knee replacements
(UKRs) by national registries is based on the pooled results of medial
and lateral implants. Consequently, little is known about the differential
performance of medial and lateral replacements and the influence
of each implant type within these pooled analyses. Using data from
the National Joint Registry for England and Wales (NJR) we aimed
to determine the proportion of UKRs implanted on the lateral side
of the knee, and their survival and reason for failure compared
with medial UKRs. By combining information on the side of operation
with component details held on the NJR, we were able to determine
implant laterality (medial
We report the first use of synchrotron xray spectroscopy to characterize and compare the chemical form and distribution of metals found in tissues surrounding patients with metal-on-metal hip replacements that failed with (Ultima hips) or without (current generation, large diameter hips) corrosion. The commonest clinical category of failure of metal-on-metal (MOM) hip replacements is “unexplained” and commonly involved a soft tissue inflammatory response. The mechanism of failure of the Ultima MOM total hip replacement includes severe corrosion of the metal stem and was severe enough to be removed from clinical use. Corrosion is not a feature that we have found in the currently used MOM bearings. To better understand the biological response to MOM wear debris we hypothesized that tissue from failed hips with implant corrosion contained a different type of metal species when compared to those without corrosion.Summary
Introduction
Our objective was to investigate how patients, general practitioners (GPs) and orthopaedic trainees, feel about the proposed governmental changes to reduce orthopaedic outpatient clinics by having GPs and specialist nurses follow-up post operative orthopaedics patients in the community. This was a cross-sectional questionnaire study of Teaching hospital and general practitioners in the Norfolk primary care trust. Of 73 orthopaedic post-operative patients who attended outpatients over a one week period in July 2007, all responded. Of 250 General Practitioners, 239 responded. Of 38 orthopaedic trainees at the level of SHO (post MRCS) and SpR’s (Eastern deanery rotation and Pott rotation) 30 responded. Main outcome measures: opinions of GPs, Surgical trainees and Patients regarding proposed changes to outpatient orthopaedic clinics. Of the patients 56 of 73 (77%) felt the surgeon was best suited to manage them post-operatively. Of these 47 felt that it was very important that the surgical team saw them post-operatively. Also 53 felt that their GP did not have sufficient knowledge and experience to adequately deal with their current orthopaedic problem. General Practitioners: Only 12 of 239 (5%) felt very confident assessing post-operative patients. Inadequate resources available to diagnose and treat post-operative complications was noted by 74% as the reason for not performing follow-up in primary care, and only 18% felt they should follow up post-operative patients. Trainees: All felt that following up their own post-operative patients was important to their training. Most patients, GPs, and orthopaedic trainees had serious doubts about proposed governmental changes to reduce orthopaedic outpatient clinics by having GPs and specialist nurses follow-up post operative orthopaedics patients in the community.
We have observed that some patients perceive their LLD to be much greater than the true LLD. A large LLD is sometimes reported by therapists, despite only a small true LLD. We have found that abduction tightness is a potent cause of apparent LLD, and report our investigations into this phenomenon.
Clinical photographs and videos have been produced to demonstrate this phenomenon. A 2-dimensional model has been made to demonstrate how the degree of abduction, offset and over-lengthening affect this phenomenon. A computer model has been used to quantify these effects.
Even with only minor abductor tightness, increasing the true length will disproportionately increase the apparent LLD. In the presence of tight abductors, increasing the offset will cause apparent shortening in the contra-lateral limb. Patients are who have adequate adduction are frequently unaware of true lengthening.
A computer system has been developed that allows rapid collection of data about joint replacements in the operating room which can then be transmitted to a server via the internet for later analysis. The programme comprises three main fields, a demographic field, an implant field and a field to allow specific questions. The specific features include:-
An unique programme linking the manufacturer’s barcodes in a readable form. A reminder system that only allows logging of the data when all the questions are answered. Flexibility with the data set. The system will be demonstrated in the course of the presentation. The perceived advantages over a paper system , validation, “windows anywhere” and confidentiality will be discussed. The adaptability of the system for use in outpatients and for the production of operation notes will be outlined. The cost, about £700, per unit plus software charges will be discussed.