Surgical site infection (SSI) after soft-tissue sarcoma (STS) resection is a serious complication. The purpose of this retrospective study was to investigate the risk factors for SSI after STS resection, and to develop a nomogram that allows patient-specific risk assessment. A total of 547 patients with STS who underwent tumour resection between 2005 and 2021 were divided into a development cohort and a validation cohort. In the development cohort of 402 patients, the least absolute shrinkage and selection operator (LASSO) regression model was used to screen possible risk factors of SSI. To select risk factors and construct the prediction nomogram, multivariate logistic regression was used. The predictive power of the nomogram was evaluated by receiver operating curve (ROC) analysis in the validation cohort of 145 patients.Aims
Methods
We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland–Altman analyses to evaluate the agreement and error between radiography and the other measurements.Aims
Methods
Patients with differentiated thyroid carcinomas (DTCs) have a favourable long-term survival. Spinal metastases (SMs) cause a decline in performance status (PS), directly affecting mortality and indirectly preventing the use of systemic therapies. Metastasectomy is indicated, if feasible, as it yields the best local tumour control. Our study aimed to examine the long-term clinical outcomes of metastasectomy for SMs of thyroid carcinomas. We collected data on 22 patients with DTC (16 follicular and six papillary carcinomas) and one patient with medullary carcinoma who underwent complete surgical resection of SMs at our institution between July 1992 and July 2017, with a minimum postoperative follow-up of five years. The cancer-specific survival (CSS) from the first spinal metastasectomy to death or the last follow-up was determined using Kaplan-Meier analysis. Potential factors associated with survival were evaluated using the log-rank test. We analyzed the clinical parameters and outcome data, including pre- and postoperative disability (Eastern Cooperative Oncology Group PS 3), lung and non-spinal bone metastases, and history of radioiodine and kinase inhibitor therapies.Aims
Methods
The aim of this study was to investigate the incidence and characteristics of instrumentation failure (IF) after total en bloc spondylectomy (TES), and to analyze risk factors for IF. The medical records from 136 patients (65 male, 71 female) with a mean age of 52.7 years (14 to 80) who underwent TES were retrospectively reviewed. The mean follow-up period was 101 months (36 to 232). Analyzed factors included incidence of IF, age, sex, BMI, history of chemotherapy or radiotherapy, tumour histology (primary or metastasis; benign or malignant), surgical approach (posterior or combined), tumour location (thoracic or lumbar; junctional or non-junctional), number of resected vertebrae (single or multilevel), anterior resection line (disc-to-disc or intravertebra), type of bone graft (autograft or frozen autograft), cage subsidence (CS), and local alignment (LA). A survival analysis of the instrumentation was performed, and relationships between IF and other factors were investigated using the Cox regression model.Aims
Methods
To evaluate the perioperative complications associated with total en bloc spondylectomy (TES) in patients with spinal tumours, based on the extent and level of tumour resection. In total, 307 patients who underwent TES in a single centre were reviewed retrospectively. There were 164 male and 143 female patients with a mean age at the time of surgery of 52.9 years (SD 13.3). A total of 225 patients were operated on for spinal metastases, 34 for a malignant primary tumour, 41 for an aggressive benign tumour, and seven with a primary of unknown origin. The main lesion was located in the thoracic spine in 213, and in the lumbar spine in 94 patients. There were 97 patients who underwent TES for more than two consecutive vertebrae.Aims
Methods
Open-wedge high tibial osteotomy (OWHTO) involves performing a corrective osteotomy of the proximal tibia and removing a wedge of bone to correct varus alignment. Although previous studies have investigated changes in leg length before and after OWHTO using X-rays, none has evaluated three-dimensional (3D) leg length changes after OWHTO. We therefore used 3D preoperative planning software to evaluate changes in leg length after OWHTO in three dimensions. The study subjects were 55 knees of 46 patients (10 men and 36 women of mean age 69.9 years) with medial osteoarthritis of the knee or osteonecrosis of the medial femoral condyle with a femorotibial angle of >185º and restricted range of motion (extension <–10º, flexion <130º), excluding those also suffering from patellofemoral arthritis or lateral osteoarthritis of the knee. OWHTO was simulated from computed tomography scans of the whole leg using ZedHTO 3D preoperative planning software. We analyzed the hip-knee-ankle angle (HKA), flexion contracture angle (FCA), mechanical medial proximal tibial angle (mMPTA), angle of correction, wedge length, 3D tibial length, 3D leg length, and 3D increase in leg length before and after OWHTO. We also performed univariate and multivariate analysis of factors affecting the change in leg length (preoperative and postoperative H-K-A angle, wedge length, and correction angle).Objective
Methods
Accurate positioning of the acetabular component is essential for achieving the best outcome in total hip arthroplasty (THA). However, the acetabular shape and anatomy in severe hip dysplasia (Crowe type IV hips) is different from that of arthritic hips. Positioning the acetabular component in the acetabulum of Crowe IV hips may be surgically challenging, and the usual surgical landmarks may be absent or difficult to identify. We analyzed the acetabular morphology of Crowe type IV hips using CT data to identify a landmark for the ideal placement of the centre of the acetabular component as assessed by morphometric geometrical analysis and its reliability. A total of 52 Crowe IV and 50 normal hips undergoing total hip arthroplasty were retrospectively identified. In this CT-based simulation study, the acetabular component was positioned at the true acetabulum with a radiographic inclination of 40° and anteversion of 20° (Figure 1). Acetabular shape and the position of the centre of the acetabular component were analyzed by morphometric geometrical analysis using the generalized Procrustes analysis (Figure 2). To describe major trends in shape variations within the sample, we performed a principal component analysis of partial warp variables (Figure 3).Aims
Patients and Methods
Implant-related infection is one of the leading reasons for failure in orthopaedics and trauma, and results in high social and economic costs. Various antibacterial coating technologies have proven to be safe and effective both in preclinical and clinical studies, with post-surgical implant-related infections reduced by 90% in some cases, depending on the type of coating and experimental setup used. Economic assessment may enable the cost-to-benefit profile of any given antibacterial coating to be defined, based on the expected infection rate with and without the coating, the cost of the infection management, and the cost of the coating. After reviewing the latest evidence on the available antibacterial coatings, we quantified the impact caused by delaying their large-scale application. Considering only joint arthroplasties, our calculations indicated that for an antibacterial coating, with a final user’s cost price of €600 and able to reduce post-surgical infection by 80%, each year of delay to its large-scale application would cause an estimated 35 200 new cases of post-surgical infection in Europe, equating to additional hospital costs of approximately €440 million per year. An adequate reimbursement policy for antibacterial coatings may benefit patients, healthcare systems, and related research, as could faster and more affordable regulatory pathways for the technologies still in the pipeline. This could significantly reduce the social and economic burden of implant-related infections in orthopaedics and trauma.
We analyzed the acetabular morphology of Crowe type IV hips using CT data to identify a landmark for the ideal placement of the centre of the acetabular component, as assessed by morphometric geometrical analysis, and its reliability. A total of 52 Crowe IV hips (42 patients; seven male, 35 female; mean age 68.5 years (32 to 82)) and 50 normal hips (50 patients; eight male, 42 female; mean age 60.7 years (34 to 86)) undergoing total hip arthroplasty were retrospectively identified. In this CT-based simulation study, the acetabular component was positioned at the true acetabulum with a radiological inclination of 40° and anteversion of 20°. Acetabular shape and the position of the centre of the acetabular component were analyzed by morphometric geometrical analysis using the generalized Procrustes analysis.Aims
Patients and Methods
The aims of this study were to evaluate the long-term outcome
of surgery for bone or soft-tissue metastases from renal cell carcinoma
(RCC) and to determine factors that affect prognosis. Between 1993 and 2014, 58 patients underwent surgery for bone
or soft-tissue metastases from RCC at our hospital. There were 46
men and 12 women with a mean age of 60 years (25 to 84). The mean
follow-up period was 52 months (1 to 257). The surgical sites included
the spine (33 patients), appendicular skeleton (ten patients), pelvis (eight
patients), thorax (four patients), and soft tissue (three patients).
The surgical procedures were Aims
Patients and Methods
Open wedge high tibial osteotomy (OWHTO) for medial-compartment
osteoarthritis of the knee can be complicated by intra-operative
lateral hinge fracture (LHF). We aimed to establish the relationship
between hinge position and fracture types, and suggest an appropriate
hinge position to reduce the risk of this complication. Consecutive patients undergoing OWHTO were evaluated on coronal
multiplanar reconstruction CT images. Hinge positions were divided
into five zones in our new classification, by their relationship
to the proximal tibiofibular joint (PTFJ). Fractures were classified
into types I, II, and III according to the Takeuchi classification.Aims
Patients and Methods
Dislocation is one of the most important complications in THA. Dual mobility cup (DMC) inserts reduce the risk for dislocation after total hip arthroplasty by increasing the oscillation angle. A lower rate of dislocation with use of a DMC insert has been reported in different studies. But there is no available research that clearly delineates the stability advantages of DMC inserts in primary THA. The aim of our study was to evaluate the area of the safe zone for a DMC insert, compared to a fixed insert for different anteversion angles of the femoral component. A model of the pelvis and femur were developed from computed tomography images. We defined the coordinate system of the pelvis relative to the anterior pelvic plane and the coordinate system of the femur relative to the posterior condylar plane. In our model, we simulated a positive anteversion position of the acetabular cup. The lower border for cup inclination is 50°. The safe zone was evaluated for the following range of motion of the implant: 120° of flexion, 90° of flexion 30° of internal rotation, 30° of extension, 40° of abduction, 40° of adduction, and 30° of external rotation. (Fig.1) The safe zone was calculated for both a fixed insert and a DMC insert over a pre-determined range of three-dimensional motion, and the effect of increasing the anteversion position of the femoral component from 5° to 35° quantified. The ratio of the safe zone for a DMC insert to a fixed insert was calculated.INTRODUCTION
Material and Methods
Pelvic posterior tilt change (PPTC) after THA is caused by release of joint contracture and degenerative lumbar kyphosis. PPTC increases cup anteversion and inclination and results in a risk of prosthesis impingement (PI) and edge loading (EL). There was reportedly no component orientation of fixed bearing which can avoid PI and EL against 20°PPTC. However, dual mobility bearing (DM) has been reported to have a large oscillation angle and potential to withstand EL without increasing polyethylene (PE) wear against high cup inclination such as 60∼65°. The purpose of this study was to investigate the optimal orientation of DM-THA for avoiding PI and EL against postoperative 20°PPTC.Introduction
Objective
Computer navigation systems are quite sophisticated intra-operative support systems for the precise placement of acetabular or femoral components in THA. However, few studies have addressed the clinical benefits derived from using a navigation system to achieve precise placement of the implants. The purpose of this study is to investigate the early dislocation rate of navigation-assisted primary THA through a posterior approach in order to clarify the short-term benefit of using a computer navigation system. We retrospectively reviewed the early dislocation rate (within 12 months after surgery) of 475 consecutive primary cementless or hybrid THAs with femoral head sizes ≦32mm performed via posterior approach. There were 85 men and 390 women, with a mean age of 60 years (17 to 88) at operation. Preoperative diagnoses included osteoarthritis in 384 hips, osteonecrosis in 45 hips, and others in 46 hips (ex. RA, trauma, infection, congenital disease). All THAs were planned using a 3D templating system based on the combined anteversion theory, performed by single surgeon through a posterior approach with repair of the posterior capsule, assisted by a CT-based surface matching type computer navigation system for cup implantation. All patients were directly followed up at least 1 year after surgery. We classified all 475 joints into four groups: normal or mildly deformed hips (Group A; 308 joints, ex. primary OA, Crowe group 1, osteonecrosis), moderately deformed hips (Group B; 97 joints, ex. Crowe group 2, protrusio acetabuli, Perthes like deformity), severely deformed hips (Group C; 53 joints, ex. Crowe group 3 or 4, ankylosis, fused hip), and neuromuscular and cognitive disorders (Group D; 17 joints), and examined the dislocation rate for each group.Introduction
Methods
The number of total hip arthroplasties has been increasing worldwide, and it is expected that revision surgeries will increase significantly in the near future. Although reconstructing normal hip biomechanics with extensive bone loss in the revision surgery remains challenging. The custom−made acetabular component produced by additive manufacturing, which can be fitted to a patient's anatomy and bone defect, is expected to be a predominant reconstruction material. However, there have been few reports on the setting precision and molding precision of this type of material. The purpose of this study was to validate the custom−made acetabular component regarding postoperative three−dimensional positioning and alignment. Severe bone defects (Paprosky type 3A and 3B) were made in both four fresh cadaveric hip joints using an acetabular reamer mimicking clinical cases of acetabular component loosening or osteolysis in total hip arthroplasty. On the basis of computed tomography (CT) after making the bone defect, two types of custom−made acetabular components (augmented type and tri−flanged type) that adapted to the bone defect substantially were produced by an additive manufacturing machine. A confirmative CT scan was taken after implantation of the component, and then the data were installed in an analysis workstation to compare the postoperative component position and angle to those in the preoperative planning.Introduction
Methods
Recently the taper wedged stems (TWS) are used widely in Japan because of good bone fixation and ease of the procedure. However, it is unclear how TWS get initial fixation in Japanese, especially dysplasia hip or elderly patients who had stovepipe canal. The purpose of this study is to evaluate initial bone fixation of the TWS in Japanese using computed tomography and to estimate biological bone fixation of the TWS using the Tomosynthesis. We evaluated 100 hips underwent primary total hip arthroplasty using TWS. All patients were performed computed tomography within 2 weeks postoperatively and evaluated which part of the canal was made contact with the stem. 24 hips were male and 76 hips were female. According to the canal flare index, 9 hips were champagne flute canal, 80 hips were normal canal and 11 hips were Stovepipe canal. 10 hips were Dorr type A, 80 hips were Dorr type B and 10 hips were Dorr type C. The initial bone fixation was classified as Medio-lateral fit (fixed at Gruen zone 2 and 7), Flare fit (fixed at zone 2 and 6), Varus 2-point fit (fixed at zone 3 and 7), Valgus 3-point fit (fixed at zone 2, 5 and 7), Distal fit (fixed at zone 3 and 5), Total fit (fixed at zone 2,3,5,6 and 7) by the stem A-P view. Moreover, we defined Medio-lateral fit, Flare fit and Total fit as Adequate fit, Varus 2-point fit and Valgus 3-point fit as Varus or Valgus fit, Distal fit as Distal fit. The stem alignment was classified as flexion, neutral and extension by the stem lateral view. Femoral component fixation was graded as bone ingrowth, fibrous ingrowth and unstable by hip radiographs after surgery at 1 year. Spot-welds were evaluated using tomosynthesis after surgery at 6 months.Background
Methods
Total Of the 54 patients who underwent TES for a primary tumour between
1993 and 2010, 19 died and four were lost to follow-up. In January
2012, a questionnaire was sent to the 31 surviving patients. This
included the short form-36 to assess HRQoL and questions about the
current condition of their disease, activities of daily living (ADL)
and surgery. The response rate was high at 83.9% (26/31 patients).
We found that most patients were satisfied and maintained good performance
of their ADLs. The mental health status and social roles of the HRQoL scores
were nearly equivalent to those of healthy individuals, regardless
of the time since surgery. There was significant impairment of physical
health in the early post-operative years, but this usually returned
to normal approximately three years after surgery. Cite this article:
In 1999, we developed a technique for biological
reconstruction after excision of a bone tumour, which involved using
autografts of the bone containing the tumour treated with liquid
nitrogen. We have previously reported the use of this technique
in 28 patients at a mean follow up of 27 months (10 to 54). In this study, we included 72 patients who underwent reconstruction
using this technique. A total of 33 patients died and three were
lost to follow-up, at a mean of 23 months (2 to 56) post-operatively,
leaving 36 patients available for a assessment at a mean of 101
months 16 to 163) post-operatively. The methods of reconstruction included
an osteo-articular graft in 16, an intercalary in 13 and, a composite
graft with prosthesis in seven. Post-operative function was excellent in 26 patients (72.2%),
good in seven (19.4%), and fair in three (8.3%) according to the
functional evaluation system of Enneking. No recurrent tumour occurred
within the grafts. The autografts survived in 29 patients (80.6%),
and the rates of survival at five and ten years were 86.1% and 80.6
%, respectively. Seven of 16 osteo-articular grafts (44%) failed
because of fracture or infection, but all the composite and intercalary
grafts survived. The long-term outcomes of frozen autografting, particularly using
composite and intercalary grafts, are satisfactory and thus represent
a good method of treatment for patients with a sarcoma of bone or
soft tissue. Cite this article:
It has recently been reported that the transverse
acetabular ligament (TAL) is helpful in determining the position
of the acetabular component in total hip replacement (THR). In this
study we used a computer-assisted navigation system to determine
whether the TAL is useful as a landmark in THR. The study was carried
out in 121 consecutive patients undergoing primary THR (134 hips),
including 67 dysplastic hips (50%). There were 26 men (29 hips)
and 95 women (105 hips) with a mean age of 60.2 years (17 to 82)
at the time of operation. After identification of the TAL, its anteversion
was measured intra-operatively by aligning the inferomedial rim
of the trial acetabular component with the TAL using computer-assisted
navigation. The TAL was identified in 112 hips (83.6%). Intra-observer reproducibility
in the measurement of anteversion of the TAL was high, but inter-observer
reproducibility was moderate. Each surgeon was able to align the trial component according
to the target value of the angle of anteversion of the TAL, but
it was clear that methods may differ among surgeons. Of the measurements
of the angle of anteversion of the TAL, 5.4% (6 of 112 hips) were
outliers from the safe zone. In summary, we found that the TAL is useful as a landmark when
implanting the acetabular component within the safe zone in almost
all hips, and to prevent it being implanted in retroversion in all
hips, including dysplastic hips. However, as anteversion of the
TAL may be excessive in a few hips, it is advisable to pay attention
to individual variations, particularly in those with severe posterior
pelvic tilt. Cite this article:
The flexor carpi radialis (FCR) approach is widely used for volar plate fixation of distal radius fractures. However, patients sometimes complain of postoperative numbness at the thenar eminence. We propose this is derived from injury to the palmar cutaneous branch of the median nerve (PCBm). From March 2010 to March 2012, we performed 10 operations of volar plate fixation for distal radius fractures using the FCR approach. We detected the PCBm intraoperatively and investigated the anatomy.Introduction
Materials and methods