Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 130 - 130
1 Mar 2017
Ryu K Iriuchishima T Saito S Nagaoka M Ryu J Tokuhashi Y
Full Access

Introduction

Oriental people habitually adopt formal sitting and squatting postures, the extreme flexion of the knees allowing of this. The influence exercised by pressure and posture are, therefore, found at the posterior side of knee joint. However, we don't have many report about articular cartilage of posterior femoral condyle.

Objectives

The purpose of this study was to reveal the accurate prevalence and related factors to the presence of degenerative changing of the articular cartilage of posterior femoral condyle in cadaveric knee joints.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 141 - 141
1 Jan 2016
Ryu K Suzuki T Iriuchishima T Kojima K Saito S Ishii T Nagaoka M Tokuhashi Y
Full Access

Objective

Mobile bearing unicompartmental knee arthroplasty (UKA) is an effective and safe treatment for osteoarthritis of the medial compartment. However, mobile-bearing UKA needs accurate ligament balancing of flexion and extension gaps to prevent dislocation of the mobile meniscal bearing. Instability can lead to dislocation of the insert. The phase 3 instruments of the Oxford UKA use a balancing technique for the flexion gap (90° of flexion) and extension gap (20° of flexion), thereby focusing attention on satisfactory soft tissue balancing. With this technique, spacers are used to balance the flexion and extension gap. However, gap kinematics in another flexion angle of mobile-bearing UKA is unclear. We developed UKA tensor for mobile-bearing UKA and we assessed the accurate gap kinematics of UKA.

Materials and Methods

Between 2012 and 2013, The Phase 3 Oxford Partial Knee UKA (Biomet Inc., Warsaw, IN) were carried out in 48 patients (71 knees) for unicompartmental knee osteoarthritis or spontaneous osteonecrosis of the medial compartment. The mean age of patients at surgery was 71.6 years and the mean follow-up period was 1.7 years. The mean preoperative coronal plane alignment was 7.4° in varus. The indications for UKA included disabling knee pain with medial compartment disease; intact ACL and collateral ligaments; preoperative contracture of less than 15°; and preoperative deformity of <15°. Each surgery was performed by using different spacer block with 1-mm increments and the meniscal bearing lift-off tests according to surgical technique. We developed newly tensor for mobile bearing UKA which designed to permit surgeons to measure multiple range of the joint medial compartment/joint component gap, while applying a constant joint distraction force (Figure 1). We assessed the intra-operative joint gap measurements at 0, 20, 60, 90 and 120 of flexion with 100N, 125N and 150N of joint distraction forces.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 151 - 151
1 Jan 2016
Seki M Saito S Ishii T Suzuki G Kikuta S Oikawa N Lee H Kinoshita G Hasegawa T Tokuhashi Y
Full Access

Purpose

A Trabecular Metal Modular Acetabular System (Zimmer, Warsaw, Indiana, USA) is a peripheral rim expansion (elliptical) cup, i.e. a non-hemispherical cup. Radiologically a non-hemispherical cup may be deferent from other conventional hemispherical cups. We reviewed radiological findings of a Trabecular Metal Modular Acetabular System chronologically.

Methods

Twenty six patients with osteoarthritis underwent primary total hip arthroplasty (THA) using a Trabecular Metal Modular Acetabular System from 2011 to April 2013. Twenty five patients (follow-up rate: 96.2%) 31 hips could be followed-up over a year were registered. In common, the diameter of every femoral head was 32 mm. We planned the acetabular cup inclination angle to be 45-degree, the cup coverage with host-bone (cup-CE angle) to be over 10-degree, and high hip center was allowed up to 20mm. In case of the cup-CE angle under 10-degree, an acetabular cup was placed medially using Dorr's medial protrusio technique. We established the medial protrusion angle indicating the degree of medial protrusion of an acetabular cup over the pelvic internal wall. The medial protrusion angle was defined by the center point of THA (C) and the 2 cross-points (X1, X2) which the outline of an acetabular cup crosses the Kohler's line (Figure 1). The cup anteversion angle was measured by the method of Lewinnek, and the cup fixation was evaluated according to the Tompkin's classification.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 543 - 543
1 Dec 2013
Suzuki T Ryu K Yamada T Kojima K Saito S Tokuhashi Y
Full Access

Introduction

Accurate soft tissue balancing in knee arthroplasty is essential in order to attain good postoperative clinical results. In mobile-bearing UKA (Oxford Partial Knee unicompartmental knee arthroplasty, Biomet), since determination of the thickness of the spacer block depends on the individual surgeon, it will vary and it will be difficult to attain appropriate knee balancing. The first objective of the present study was to investigate flexion and extension medial unicompartmental knee gap kinematics in conjunction with various joint distraction forces. The second objective of the study was to investigate the accuracy of gap measurement using a spacer block and a tensor device.

Methods

A total of 40 knees in 31 subjects (5 men and 26 women) with a mean age of 71.5 years underwent Oxford UKA for knee osteoarthritis and idiopathic osteonecrosis of the medial compartment. According to instructions of Phase 3 Oxford UKA, spacer block technique was used to make the extension gap equal to the flexion gap. Adequate thickness of the spacer block was determined so that the surgeon could easily insert and remove it with no stress. Following osteotomy, the tensor devise was used to measure the medial compartmental gap between the femoral trial prosthesis and the tibial osteotomy surface (joint component gap) (Fig. 1 and 2). The medial gap was measured at 20° of knee flexion (extension gap) and 90° of knee flexion (flexion gap) with 25N, 50N, 75N, 100N, 125N, 150N of joint distraction force. Corresponding size of bearing was determined for the prosthesis. The interplay gap was calculated by subtracting the thickness of the tibial prosthesis and the thickness of the selected size of bearing from the measured extension and flexion gaps.