header advert
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 77 - 77
1 Mar 2021
Wang J Roberts S McCarthy H Tins B Gallacher P Richardson J Wright K
Full Access

Abstract

Objectives

Meniscus allograft and synthetic meniscus scaffold (Actifit®) transplantation have shown promising outcomes for symptoms relief in patients with meniscus deficient knees. Untreated chondral defects can place excessive load onto meniscus transplants and cause early graft failure. We hypothesised that combined ACI and allograft or synthetic meniscus replacement might provide a solution for meniscus deficient individuals with co-existing lesions in cartilage and meniscus.

Methods

We retrospectively collected data from 17 patients (16M, 1F, aged 40±9.26) who had ACI and meniscus allograft transplant (MAT), 8 patients (7M, 1F, aged 42±11) who underwent ACI and Actifit® meniscus scaffold replacement. Other baseline data included BMI, pre-operative procedures and cellular transplant data. Patients were assessed by pre-operative, one-year and last follow-up Lysholm score, one-year repair site biopsy, MRI evaluations.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_16 | Pages 12 - 12
1 Oct 2017
Bhattacharjee A McCarthy H Tins B Roberts S Kuiper J Harison P Richardson J
Full Access

The current study aims to ascertain the outcome of ACI with simultaneous transplantation of an autologous bone plug for the restoration of osteoarticular defects in the femoral condyle of the knee (‘Osplug’ technique).

Seventeen patients (mean age of 27±7 years), twelve with Osteochondritis dissecans (OD) and five with an osteochondral defect (OCD) was treated with unicortical autologous bone graft combined with ACI (‘Osplug’ technique). Functional outcome was assessed with Lysholm scores obtained for 5 years post-operatively. The repair site was evaluated with the Oswestry Arthroscopy Score (OAS), MOCART MRI score and ICRS II histology score.

The mean defect size was 4.5±2.6 SD cm² and mean depth was 11.3±5 SD mm. A significant improvement of Lysholm score from 45 (IQR 24, range 16–79) to 77 (IQR 28, range 41–100) at 1 year (p-value 0.001) and 70 (IQR 35, range 33–91) at 5 years (p-value 0.009). The mean OAS of the repair site was 6.2 (range 0–9) at a mean of 1.3 years. The mean MOCART score was 61 ± 22SD (range 20–85) at 2.6 ± 1.8SD years. Histology demonstrated generally good integration of the repair cartilage with the underlying bone. Poor lateral integration of the bone graft on MRI and low OAS were significantly associated with a poor outcome and failure.

The Osplug technique shows significant improvement of functional outcome for up to 5 years. This is the first report describing the association of bone graft integration with functional outcome after such a procedure.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 67 - 67
1 May 2017
Bhattacharjee A McCarthy H Tins B Kuiper J Roberts S Richarson J
Full Access

Background

Structural and functional outcome of bone graft with first or second generation autologous chondrocyte implantation (ACI) in osteochondral defects has not been reported.

Methods

Seventeen patients (mean age of 27±7 years, range 17–40), twelve with osteochondritis dissecans (OD) (ICRS Grade 3 and 4) and five with isolated osteochondral defect (OCD) (ICRS Grade 4) were treated with a combined implantation of a unicortical autologous bone graft with ACI (the Osplug technique). Functional outcome was assessed with Lysholm scores. The repair site was evaluated with the Oswestry Arthroscopy Score (OAS), MOCART score and ICRS II histology score. Formation of subchondral lamina and lateral integration of the bone grafts were evaluated from MRI scans.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 1 - 1
1 Jul 2012
Gregory J Ockendon M Cool W Cribb G Mangham D Lalam R Tins B
Full Access

Introduction

CT guided percutaneous radiofrequency thermo coagulation is the treatment of choice for osteoid osteomas. Good results with a low complication rate have been shown for spinal lesions. When lesions are within close proximity to neurological structures or if patients have radicular symptoms surgery rather than radiofrequency ablation has been advocated. We present our experience of radiofrequency ablation of spinal osteoid osteomas which are less than 5mm from neurological structures, including those causing radicular symptoms.

Methods

Data was collected prospectively on all patients with a spinal osteoid osteoma within 5mm of nerve roots or the spinal cord as measured on CT scanning.

There were nine patients, five female and four males. Four were located in the thoracic spine, three in the lumbar spine and two in the cervical spine. The mean distance to the nearest neurological structure was 3mm. Radicular symptoms were present in two patients. The mean number of probe positions used was two. Lesions were heated to 90 degrees for 5 minutes for each probe position. There were two cases of recurrence, both treated successfully with one further procedure each. There were no cases of neurological injury. The two patients with radicular symptoms had full resolution of their symptoms. At a mean follow up of 2 years following treatment all patients are asymptomatic.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 3 - 3
1 Jul 2012
Cribb G Cool P Lalam R Tins B Mangham D
Full Access

Introduction

Chondroblastomas are rare bone tumours accounting for approximately 1% of all benign bone lesions. They occur in children and adolescents and are more frequent in males.

The conventional treatment for chondroblastomas is surgery, however, this can be difficult and disabling due to the apo- or epiphyseal location. Surgery is curative in most cases, but recurrence rates of 10%–35% have been reported in the literature. Radiofrequency ablation is well established in the treatment of osteoid osteomas and painful bone metastases. We report our experience with the use of radiofrequency ablation in the treatment of chondroblastomas.

Methods

Seven patients were identified from our Tumour database with biopsy proven chondroblastomas who were treated with Percutaneous CT Guided Radiofrequency Thermo coagulation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 15 - 15
1 Apr 2012
Gregory J Ockendon M Cool W Cribb G Mangham D Lalam R Tins B Williams D
Full Access

CT guided percutaneous radiofrequency thermocoagulation is the treatment of choice for osteoid osteomas. Good results with a low complication rate have been shown for spinal lesions. When lesions are within close proximity to neurological structures or if patients have radicular symptoms surgery rather than radiofrequency ablation has been advocated. We present our experience of radiofrequency ablation of spinal osteoid osteomas which are less than 5mm from neurological structures, including those causing radicular symptoms.

Data was collected prospectively on all patients with a spinal osteoid osteoma within 5mm of nerve roots or the spinal cord as measured on CT scanning.

There were nine patients, five female and four male with a mean age of 15 years. Four tumours were located in the thoracic spine, three in the lumbar spine and two in the cervical spine. The mean distance to the nearest neurological structure was 3mm. Radicular symptoms were present in two patients. The mean number of probe positions used was two. Lesions were heated to 90 degrees for 5 minutes for each probe position. There were two cases of recurrence, both treated successfully with one further procedure each. There were no cases of neurological injury. The two patients with radicular symptoms had full resolution of their symptoms. At a mean follow up of 2 years following treatment all patients are asymptomatic.

Radiofrequency ablation can be safely performed to treat osteoid osteomas located within 5mm of neurological structures and has a low rate of recurrence.