The kinematic alignment (KA) approach to total knee arthroplasty (TKA) has recently increased in popularity. Accordingly, a number of derivatives have arisen and have caused confusion. Clarification is therefore needed for a better understanding of KA-TKA. Calipered (or true, pure) KA is performed by cutting the bone parallel to the articular surface, compensating for cartilage wear. In soft-tissue respecting KA
The aim of this study is to evaluate the clinical results of operative intervention for femoral metastases which were selected based on expected survival and to discuss appropriate surgical strategies. From 2002 to 2017, 148 consecutive patients undergoing surgery for femoral metastasis were included in this study. Prognostic risk assessments were performed according to the Katagiri and revised Katagiri scoring system. In general, the low-risk group underwent resection and reconstruction with endoprosthetic replacement (EPR), while the high-risk group underwent internal fixation (IF) and radiation therapy. For the intermediate-risk group, the operative choice depended on the patient’s condition, degree of bone destruction, and radio-sensitivity. Overall survival, local failure, walking ability, and systemic complications were evaluated.Aims
Methods
Our objective was to predict the knee extension strength and post-operative function in quadriceps resection for soft-tissue sarcoma of the thigh. A total of 18 patients (14 men, four women) underwent total or partial quadriceps resection for soft-tissue sarcoma of the thigh between 2002 and 2014. The number of resected quadriceps was surveyed, knee extension strength was measured with the Biodex isokinetic dynamometer system (affected side/unaffected side) and relationships between these were examined. The Musculoskeletal Tumor Society (MSTS) score, Toronto Extremity Salvage Score (TESS), European Quality of Life-5 Dimensions (EQ-5D) score and the Short Form 8 were used to evaluate post-operative function and examine correlations with extension strength. The cutoff value for extension strength to expect good post-operative function was also calculated using a receiver operating characteristic (ROC) curve and Fisher’s exact test.Objectives
Methods
The purpose of this study was to examine if Sugioka's transtrochanteric rotational osteotomy (TRO) of the femoral head could be a valid option in treating idiopathic osteonecrosis of the femoral head. Thirty-two TROs performed in 29 patients between 1985 and 2006 were studied. Patient age at operation ranged from 16 to 56 years (average, 36 years). Thirteen hips were in women and 19 hips in men. Height was 165 cm and weight 63 kg (Body Mass Index 23) on average. Risk factors were corticosteroid use in 18 hips and excessive alcohol consumption in 15 hips (2 of them had both backgrounds), while neither of them was found with 1 hip. Bilateral hips were affected in 19 patients and 3 of them underwent bilateral TROs sequentially. The femoral head was rotated anteriorly in 26 hips and posteriorly in 6 hips. For fixation of the osteotomy site, large femoral screws had been used till 1995 (Group 1, 9 hips), and since 1996 an AO angle plate or a compression hip screw has been used (Group 2, 13 hips). Since 2003, pre-operative planning was performed more meticulously and the distal part of the joint capsule was cut after osteotomy as described by Atsumi (Group 3, 10 hips). The average follow-up period was 6.5 years (range, 2 to 21 years).Introduction
Methods
At the revision surgery of the cemented Total hip arthroplasty (THA), complete removal of an old cement mantle of the femur without loosening is very difficult. It can be associated with complications, such as femoral fracture, perforation and femoral bone loss. Cement-within-cement technique (CWCT) of femoral revision is very useful and advantageous without those complications for special cases. We reviewed the experiential radiological outcomes using CWCT for the cemented femoral revision. Between 1999 and 2006, we performed seventeen of revision THA using CWCT in 17 patients. There were four men and 13 women, with an average age of 75 years (range 68 to 87), with an average follow up of 39 months (range 12 to 87). The reasons for revision surgery were eleven for cup loosening, 5 for recurrent dislocation and one technical failure of stem insertion intra-operatively. An original Charnley stem (Depuy, Leeds, England) was implanted in six cases, an Exeter femoral component (Stryker Benoist Girard, Herouville, Saint-Clair, France) was in 10 and another stem in one. Posterolateral approach without trochanteric osteotmy was performing for all patients. After the femoral component was removed, the cement mantle was examined in detail, to confirm cement-bone interface and cement fracture. The cement mantle was washed with a pulsatile lavage to clean and to be dried. If necessary, the surface of the cement mantle was reamed. A double mix of Simplex P cement (Stryker Limerick, Limerick, Ireland) in liquid phase was inserted within the cement mantle by a cement gun with a thin nozzle(Stryker Instruments Kalamazoo, US). Thereafter suction and pressuriser were used, and a femoral component was inserted. The results of this study were that the intra-operative complication was two fractures of the greater trochanter at the stem removed and was one shaft perforation at a new original Charnley stem inserted. The stem position was one valgus and 3 varus stem position of more than 2 degrees. Radiographic outcomes showed no stem loosening, no radiolucent line at the bone-cement interface, nor any osteolysis in the patients at final follow-up. We conclude that this cement-within-cement technique is good radiographic outcomes up to 87 months and this technique should be used with the thinner femoral component than the previous.