We sought to determine the short to medium-term clinical and radiographic outcomes using a short stem in young adults with a proximal femoral deformity (PFD). We prospectively studied 31 patients (35 hips) with PFDs treated with an uncemented primary THA using a short stem with cervicometaphyseal fixation between 2011–2018. There were 19 male (23 hips) and 12 female (12 hips) patients, with a mean BMI of 26.7±4.1 kg/m2. Twelve cases had a previous surgical procedure, and six of them were failed childhood osteotomies. Mean age of the series was 44±12 years, mean follow-up was 81±27 months and no patients were lost to follow-up. PFDs were categorized according to a modified Berry´s classification. Average preoperative leg-length discrepancy (LLD) was −16.3 mm (−50 to 2). At a mean time of 81 months of follow-up, survival rate was 97% taking revision of the stem for any reason and 100% for aseptic loosening as endpoints. No additional femoral osteotomy was required in any case. Average surgical time was 66 minutes (45 to 100). There was a significant improvement in the mHHS score when comparing preoperative and postoperative values (47.3±10.6 vs. 92.3±3.7, p=0.0001). Postoperative LLD was in average 1 mm (−9 to 18) (p=0.0001). According to Engh's criteria, all stems were classified as stable without signs of loosening. Postoperative complications included 1 pulmonary embolism, 1 neurogenic sciatic pain, 1 transient sciatic nerve palsy that recovered completely after six months, and 2 acute periprosthetic joint infections. One patient suffered a Vancouver B2 periprosthetic femoral fracture 45 days after surgery and was revised with a modular distally fixed uncemented fluted stem. A type 2B short stem evidenced promising outcomes at short to medium-term follow up in young adult patients with PFDs, avoiding the need for corrective osteotomies and a revision stem.
Traditional radiographic criteria might underestimate or fail to detect subtle types of acetabular dysplasia. Acetabular sector angles (ASA) can measure the degree of anterior and posterior coverage of the femoral head on computed tomography (CT). This study aims to determine ASA values at different axial levels in a cohort of (1) asymptomatic, high-functioning hips without underlying hip pathology (controls); and (2) symptomatic, dysplastic hips that underwent periacetabular osteotomy (PAO). Thereby, we aimed to define CT-based thresholds for hip dysplasia and its subtypes. This is an IRB approved cross-sectional study of 51 high functioning, asymptomatic patients (102 hips) (Oxford Hip Score >43), without signs of osteoarthritis (Tönnis grade≤1), who underwent a CT scan of the pelvis (mean age: 52.1±5.5 years; 52.9% females); and 66 patients (72 hips) with symptomatic hip dysplasia treated with peri-acetabular osteotomy (PAO) (mean age: 29.3±7.3 years; 85.9% females). Anterior and posterior acetabular sector angles (AASA & PASA) were measured by two observers at three CT axial levels to determine equatorial, intermediate, and proximal ASA. Inter- and intra-observer reliability coefficient was high (between 0.882–0.992). Cut-off values for acetabular deficiency were determined based on Receiver Operating Characteristic (ROC) curve analysis, area under the curve (AUC) was calculated. The dysplastic group had significantly smaller ASAs compared to the Control Group, AUC was the highest at the proximal and intermediate PASA. Controls had a mean proximal PASA of 162°±17°, with a cut-off value for dysplasia of 137° (AUC: 0.908). At the intermediate level, the mean PASA of controls was 117°±11°, with a cut-off value of 107° (AUC 0.904). Cut-off for anterior dysplasia was 133° for proximal AASA (AUC 0.859) and 57° for equatorial AASA (AUC 0.868). Cut-off for posterior dysplasia was 102° for intermediate PASA (AUC 0.933). Measurement of ASA on CT is a reliable tool to identify dysplastic hips with high diagnostic accuracy. Posterior ASA less than 137° at the proximal level, and 107° at the intermediate level should alert clinicians of the presence of dysplasia.
To compare the incidence of Bone Cement Implantation Syndrome (BCIS), perioperative thromboembolic events and mortality in patients with a femoral neck fracture (FNF) treated with a hybrid total hip arthroplasty (THA) without intraoperative unfractioned heparin (UFH) (control) versus a group of patients who received intraoperative UFH before femoral cementation. We retrospectively reviewed 273 patients who underwent hybrid THA due to a FNF between 2015 and 2020. We compared a group of 139 patients without intraoperative administration of UFH (group A) with 134 patients who underwent THA with intraoperative administration of 10 UI/kg UFH (group B). UFH indication was dependent on surgeon´s preference. We assessed the advent of BCIS and 30-day thromboembolic events, as well as 90-day and 1-year mortality. BCIS was observed in 51 cases (18%), defined as Grade 1 (O2% < 94% or fall in systolic blood pressure of 20% to 40%) in 37 cases (13%) and Grade 2 (O2% < 88% or fall in systolic blood pressure of > 40%) in 14 cases (5%). Forty-seven BCIS (35%) were observed in the group that received UFH and 4 BCIS (3%) in the control group (p <0.001). Multivariate regression model showed that intraoperative UFH (OR=18, CI95% 6–52) and consumption of oral anticoagulants (OR=3.3, CI95% 1–10) had an increased risk of developing BCIS. Five patients developed a pulmonary embolism in the UFH group while 2 patients presented this complication in the non UFH group (p=0.231). Mortality was 1% for both groups at 90 days PO (p= 0.98), 2% at 1 year for group A and 3% for group B (p =0.38). BCIS in our series was 18%. We found a paradoxically 17-fold significant increase of BCIS with the use of UFH. Heparin did not prevent BCIS, thromboembolic events and mortality in this group of patients.
The use of cementless acetabular components is currently the gold standard for treatment in total hip arthroplasty (THA). Porous coated cups have a low modulus of elasticity that enhances press-fit and a surface that promotes osseointegration. Monoblock acetabular cups represent a subtype of uncemented cup with the liner moulded into the metal shell, minimizing potential backside wear and eliminating the chance of mal-seating. The aim of this study was to compare the short-term clinical and radiographic performances of a modular cup with that of a monoblock cup, with particular interest in the advent of lucent lines and their correlation with clinical outcomes. In this multi-surgeon, prospective, randomized, controlled trial, 86 patients undergoing unilateral THA were recruited. Participants were randomized to either a porous-coated, modular metal-on-polyethylene (MoP) acetabular component (n=46) or a hydroxyapatite (HA)- and titanium-coated monoblock shell with ceramic-on-ceramic (CoC) bearing (n=42). The porous-coated cup had an average pore size of 250 microns with an average volume porosity of 45%, whereas the monoblock shell had an average pore size of 300 microns with an average volume porosity of 48% and a HA coating thickness of 80 nm. There were no baseline demographic differences between both groups regarding sex, age, body mass index (BMI), or American Society of Anaesthesia (ASA) class (p>0.05). All of the sockets were under-reamed by 1 mm. Radiographs and patient-reported outcome measures (PROMs), including modified Harris Hip Score (mHHS), Western Ontario and McMaster Universities Arthritis Index (WOMAC) and University of California at Los Angeles (UCLA) Hip Score, were available for evaluation at a minimum of 2 years of follow-up. A radiolucent distance between the cup and acetabulum of ≥0.5 mm was defined as gap if it was diagnosed from outset or as radiolucency if it had sclerotic edges and was found on progressive x-ray analyses. Thirty-two gaps (69%) were found in the modular cup group and 28 (6%) in the monoblock one (p=0.001). Of the former, 17 filled the gaps whereas 15 turned into a radiolucency at final assessment. Of the latter, only 1 of the gaps turned into a radiolucency at final follow-up (p 0.05) in both groups. Only the porous-coated cup was an independent predictor of lucent lines (OR:0.052, p=0.007). No case underwent revision surgery due to acetabular loosening during the study period. Only 2 cases of squeaking were reported in the CoC monoblock shell. Both porous-coated modular and hydroxyapatite-coated monoblock cups showed successful clinical results at short-term follow-up, however, the former evidenced a significantly higher rate of radiolucent line occurrence, without any association with PROMs. Since these lines indicate the possibility of future cup loosening, longer follow-up and assessment are necessary.
Although there is some clinical evidence of ceramic bearings being associated with a lower infection rate after total hip arthroplasty (THA), available data remains controversial since this surface is usually reserved for young, healthy patients. Therefore, we investigated the influence of five commonly-used biomaterials on the adhesion potential of four biofilm-producing bacteria usually detected in infected THAs. In this in-vitro research, we evaluated the ability of We found no differences on global bacterial adhesion between the different surfaces. In this study, ceramic bearings appeared not to be related to a lower bacterial adhesion than other biomaterials. However, different adhesive potentials among bacteria may play a major role on infection's inception.
Following a total hip arthroplasty (THA), early hospital readmission rates of 3–8% are considered as ‘acceptable’ in terms of medical care cost policies. Surprisingly, the impact of readmissions on mortality has not been priorly portrayed. Therefore, we aimed to analyse the mortality of unplanned readmissions after primary THA at a high-volume Argentinian center. We prospectively analysed 90-day readmissions of 815 unilateral, elective THA patients operated between 2010–2014 whose medical insurance was the one offered by our institution. Mean follow-up was 51 months (range, 37–84). Median age was 69 (IQR, 62–77). We stratified our sample into readmitted and non-readmitted cohorts. Through a Cox proportional hazard model, we compared demographic characteristics, clinical comorbidities, surgical outcomes and laboratory values between both groups in order to determine association with mortality. We found 37 (4.53%) readmissions at a median time of 40.44 days (IQR: 17.46–60.69). Factors associated with readmission were: hospital stay (p=0.00); surgical time (p=0.01); chronic renal insufficiency (p=0.03); ASA class 4 (p=0.00); morbid obesity (p=0.006); diabetes (p=0.04) and a high Charlson Index (p=0.00). Overall mortality rate of the series was 3.31% (27/815). Median time to mortality was 455.5 days (IQR: 297.58–1170.65). One-third (11/37) of the readmitted patients died, being sepsis non-related to the THA the most common cause of death. After adjusting for confounders, 90-day readmissions remained associated with mortality with an adjusted HR of 3.14 (CI95%: 1.05–9.36, p=0.04). Unplanned readmissions were an independent risk factor for future mortality, increasing 3 times the risk of a decease eventuality.
Femoral offset restoration is related to low rates of wear and dislocation. Replication of the native hip anatomy improves prosthesis survival, whereas increasing the femoral offset elevates the torque stresses, thus inducing a risk of suboptimal stem fixation. Although the Corail (DePuy Synthes, St Priest, France) uncemented stem has an excellent record of fixation, an unexpectedly number of aseptic loosenings has been noted in our institution. We sought to characterize the clinical parameters observed in a group of patients who have experienced metaphyseal aseptic loosenings with the collarless version of the Corail uncemented femoral component; describe the radiographic findings in this group of patients; expose the intraoperative findings in the cases that needed revision surgery and to calculate a possible frequency of this complication. We present a series of 15 metaphyseal debondings of the collarless version of the Corail uncemented stem in primary total hip arthroplasty. Eleven men and four woman with an average age of 60 years old (range: 42 to 81 years old) and a previous history of osteoarthritis presented with thigh pain and limping at an average of 33 months postoperative (range: 5 to 100 months). Seven cases presented a Dorr´s classification type A femur and 8 cases a type B femur. In 10 of the 15 cases a 36 mm ceramic on ceramic bearing surface was implanted and in 5 a 28 mm diameter ceramic on polyethylene pair. Radiographic assessment of the failures evidenced an increase in femoral offset of 6.2 mm in average (range: 0 to 17 mm). Nine of the 15 cases had a standard offset stem and 3 an extended offset stem. Leg length discrepancy was in average 2.4 mm (range: 0 to 8 mm). None of the failures presented a more than 2 mm subsidence. Alignment of these stems was in average 2.1 degrees of varus (range: 0 to 5 degrees). Six cases were revised to a long cemented or uncemented stem, 2 cases were lost and 7 cases are awaiting revision surgery. Although the incidence of this complication was low (15 failures in 855 cases in 10 years = 1.75%), we are concerned about the real magnitude of this problem, as this mode of failure was observed up to 8 years after implantation. Enhanced lateralization of the hip, independently of the type of stem, may have played a role in the infrequent early failures of this popular design. Routine use of “fine tunning” preoperative planning in order to avoid offset enhancement is strongly reccommended, as this was the only suspected factor that was present in almost all the failures we observed.