Distracted driving is now the number one cause of death among teenagers in the United States of America according to the National Highway Traffic Safety Administration. However, the risks and consequences of driving while distracted spans all ages, gender, and ethnicity. The Distractions on the Road: Injury eValuation in Surgery And FracturE Clinics (DRIVSAFE) Study aimed to examine the prevalence of distracted driving among patients attending hospital-based orthopaedic surgery fracture clinics. We further aimed to explore factors associated with distracted driving. In a large, multi-center prospective observational study, we recruited 1378 adult patients with injuries treated across four clinics (Hamilton, Ontario, Toronto, Ontario, Calgary, Alberta, Halifax, Nova Scotia) across Canada. Eligible patients included those who held a valid driver's license and were able to communicate and understand written english. Patients were administered questions about distracted driving. Data were analyzed with descriptive statistics. Patients average age was 45.8 years old (range 16 – 87), 54.3% male, and 44.6% female (1.1% not disclosed). Of 1361 patients, 1358 self-reported distracted driving (99.8%). Common sources of distractions included talking to passengers (98.7%), outer-vehicle distractions (95.5%), eating/drinking (90.4%), music listening/adjusting the radio (97.6%/93.8%), singing (83.2%), accepting phone calls (65.6%) and daydreaming (61.2%). Seventy-nine patients (6.3%), reported having been stopped by police for using a handheld device in the past. Among 113 drivers who disclosed the cause of their injury as a motor vehicle crash (MVC), 20 of them (17%) acknowledged being distracted at the time of the crash. Of the participants surveyed, 729 reported that during their lifetime they had been the driver in a MVC, with 226 (31.1%) acknowledging they were distracted at the time of the crash. Approximately, 1 in 6 participants in this study had a MVC where they reported to be distracted. Despite the overwhelming knowledge that distracted driving is dangerous and the recognition by participants that it can be dangerous, a staggering amount of drivers engage in distracted driving on a fairly routine basis. This study demonstrates an ongoing need for research and driver education to reduce distracted driving and its devastating consequences.
To assess the current literature on suture anchor placement for the purpose of identifying factors that lead to suture anchor perforation and techniques that reduce the likelihood of complications. Three databases (PubMed, Ovid MEDLINE, EMBASE) were searched, and two reviewers independently screened the resulting literature. Methodological quality of all included papers was assessed using Methodological Index for Non-Randomized Studies criteria and the Cochrane Risk of Bias Assessment tool. Results are presented in a narrative summary fashion using descriptive statistics. Fourteen studies were included in this review. Four case series (491 patients, 56.6% female, mean age 33.9 years), nine controlled cadaveric/laboratory studies (111 cadaveric hips and 12 sawbones, 42.2% female, mean age 60.0 years), and one randomized controlled trial (37 hips, 55.6% female, mean age 34.2 years) were included. Anterior cortical perforation by suture anchors led to pain and impingement of pelvic neurovascular structures. The anterior acetabular positions (three to four o'clock) had the thinnest bone, smallest rim angles, and highest incidence of articular perforation. Drilling angles from 10° to 20° measured off the coronal plane were acceptable. The mid-anterior (MA) and distal anterolateral (DALA) portals were used successfully, with some studies reporting difficulty placing anchors at anterior locations via the DALA portal. Small-diameter (< 1 .8-mm) suture anchors had a lower in vivo incidence of articular perforation with similar stability and pull-out strength in biomechanical studies. Suture anchors at anterior acetabular rim positions (3–4 o'clock) should be inserted with caution. Large-diameter (>2.3-mm) suture anchors increase the likelihood of articular perforation without increasing labral stability. Inserting small-diameter (< 1 .8-mm) all-suture suture anchors (ASAs) from 10° to 20° using curved suture anchor drill guides, may increase safe insertion angles from all cutaneous portals. Direct arthroscopic visualization, use of fluoroscopy, distal-proximal insertion, and the use of nitinol wire can help prevent articular violation.
The aims of this systematic review were to describe the quantity and methodological quality of meta-analyses in orthopaedic surgery published during the last 17 years. MEDLINE, EMBASE, and PubMed, between 1 January 2000 and 31 December 2016, were searched for meta-analyses in orthopaedic surgery dealing with at least one surgical intervention. Meta-analyses were included if the interventions involved a human muscle, ligament, bone or joint.Aims
Materials and Methods
The purpose of this study was to evaluate the existing literature from 2005 to 2016 reporting on the efficacy of surgical management of patients with femoroacetabular impingement (FAI) secondary to slipped capital femoral epiphysis (SCFE). The electronic databases MEDLINE, EMBASE, and PubMed were searched and screened in duplicate. Data such as patient demographics, surgical technique, surgical outcomes and complications were retrieved from eligible studies.Objectives
Methods
To determine if there are osteochondritis dissecans (OCD) lesions of the knee that are so unstable on MRI that they are incapable of healing without operative intervention. A secondary objective was to determine the ability of orthopaedic residents to accurately grade OCD lesions according to the Kijowski criteria of stable and unstable. A retrospective review was performed of patients who had femoral condyle OCD lesions from 2009-present. Only patients with open growth plates and serial MRIs were included. Each MRI was classified according to the Kijowski classification by a junior orthopaedic surgery resident as well as an MSK trained radiologist. A weighted kappa value was used to assess the inter-rater agreement. The final analysis included 16 patients (17 knees) with 49 MRI's. The weighted kappa agreement between reviewers for overall lesion stability was moderate (0.570 [95% CI 0.237–0.757]). The initial MRI lesion was graded as stable in 59% (10/17) of the knees. Two of these 10 knees became unstable during the study period, however, both stabilised again on subsequent MRIs, one with surgery and the other without surgery. The initial MRI was graded as unstable in 41% (7/17) of the knees. Two of the seven knees (29%) later demonstrated MRI evidence of lesion stability without surgical intervention. The most important finding in this study was the ability of unstable OCD lesions on MRI to heal without operative intervention. The ability of an orthopaedic surgery resident to grade these lesions on MRI was moderate.
Health care facilities are major contributors of waste to landfills, with operating rooms estimated to assume 20–70% of this waste. With hip arthroscopy for femoroacetabular impingement (FAI) on the rise, it is important to understand its environmental impact and identify areas for greening practices. Given its minimally-invasive nature, we hypothesise overall arthroscopic waste per FAI patient case to be approximately 5 kg, with minimal biohazard waste. The purpose of this study was to determine the amount of waste produced in FAI procedures and understand the environmental impact of the procedure to aid us in developing greening practices. A single surgeon waste audit (with descriptive statistics) of five FAI hip arthroscopy procedures – categorised by: 1) normal/landfill waste; 2) recyclable cardboards and plastics; 3) biohazard waste; 4) sharp items; 5) linens; and 6) sterile wrapping – was performed in April 2015. The surgical waste (except laundered linens) from the five FAI surgeries totalled 47.4 kg, of which 21.7 kg (45.7%) was biohazard waste, 11.7 kg (24.6%) was sterile wrap, 6.4 kg (13.5%) was normal/landfill waste, 6.4 kg (13.5%) was recyclable plastics, and 1.2 kg (2.6%) was sharp items. There was an average of 9.4 kg (excluding laundered linens) of waste produced per procedure. Considerable waste, specifically biohazard waste, is produced in FAI procedures with an average of 9.4 kg of waste produced per procedure, including 4.3 kg of biohazard waste. In Canada (population 35.7 million), approximately 18 800 kg of waste (8600 kg of biohazard waste) is produced from an estimated 2000 FAI procedures performed every year. Additional recycling programs, reducing surgical overage, and continued adherence to proper waste segregation will be helpful in reducing waste production and its environmental burden. An emphasis on “green outcomes” is also required to demonstrate environmental responsibility and effectively manage and allocate finite resources.
Hip arthroscopy in the setting of hip dysplasia is controversial in the orthopaedic community, as the outcome literature has been variable and inconclusive. We hypothesise that outcomes of hip arthroscopy may be diminished in the setting of hip dysplasia, but outcomes may be acceptable in milder or borderline cases of hip dysplasia. A systematic search was performed in duplicate for studies investigating the outcome of hip arthroscopy in the setting of hip dysplasia up to July 2015. Study parameters including sample size, definition of dysplasia, outcomes measures, and re-operation rates were obtained. Furthermore, the levels of evidence of studies were collected and quality assessment was performed.Objective
Methods
The recent emergence of autologous blood concentrates, such as platelet rich plasma (PRP), as a treatment option for patients with orthopaedic injuries has led to an extensive debate about their clinical benefit. Our objective was to determine the effectiveness of autologous blood concentrates compared with control therapy in improving pain in patients with orthopaedic bone and soft tissue injuries. We conducted a systematic review of MEDLINE and EMBASE from 1996 and 1947, respectively, up to July 2010. Additional studies were identified by contacting experts, searching the bibliographies of the included studies as well as orthopaedic meeting archives. We included published and unpublished randomized controlled trials or prospective cohort studies that compared autologous blood concentrates with a control therapy in patients with an orthopaedic injury. Two reviewers, working in duplicate, abstracted data on study characteristics and protocol. Reviewers resolved disagreement by consensus.Purpose
Method
Cross-linking of polyethylene greatly reduces its wear rate in hip simulator studies. We conducted a systematic review and meta-analysis of randomized controlled trials comparing cross-linked to conventional polyethylene liners for total hip arthroplasty to determine if there is a clinical reduction of: 1) wear rates, 2) radiographic osteolysis, and 3) need for total hip revision. A systematic search of MEDLINE, EMBASE, and COCHRANE databases was conducted from inception to May 2010 for all trials involving the use of cross-linked polyethylene for total hip arthroplasty. Eligibility for inclusion in the review was: use of a random allocation of treatments; a treatment arm receiving cross-linked polyethylene and a treatment arm receiving conventional polyethylene for total hip arthroplasty; and use of radiographic wear as an outcome measure. Eligible studies were obtained and read in full by two co-authors who then independently applied the Checklist to Evaluate a Report of a Nonpharmacological Trial to each study. Pooled mean differences were calculated for the following continuous outcomes: bedding-in, linear wear rate, three dimensional linear wear rate, volumetric wear rate, and total linear wear. Pooled risk ratios were calculated for radiographic osteolysis and revision hip arthroplasty.Purpose
Method
We conducted a systematic review and meta-analysis of randomised controlled trials comparing cross-linked with conventional polyethylene liners for total hip replacement in order to determine whether these liners reduce rates of wear, radiological evidence of osteolysis and the need for revision. The MEDLINE, EMBASE and COCHRANE databases were searched from their inception to May 2010 for all trials involving the use of cross-linked polyethylene in total hip replacement. Eligibility for inclusion in the review included the random allocation of treatments, the use of cross-linked and conventional polyethylene, and radiological wear as an outcome measure. The pooled mean differences were calculated for bedding-in, linear wear rate, three-dimensional linear wear rate, volumetric wear rate and total linear wear. Pooled risk ratios were calculated for radiological osteolysis and revision hip replacement. A search of the literature identified 194 potential studies, of which 12 met the inclusion criteria. All reported a significant reduction in radiological wear for cross-linked polyethylene. The pooled mean differences for linear rate of wear, three-dimensional linear rate of wear, volumetric wear rate and total linear wear were all significantly reduced for cross-linked polyethylene. The risk ratio for radiological osteolysis was 0.40 (95% confidence interval 0.27 to 0.58; I2 = 0%), favouring cross-linked polyethylene. The follow-up was not long enough to show a difference in the need for revision surgery.
Giant cell tumor (GCT) of bone is an osteolytic tumor that is locally aggressive and potentially metastatic. The pathogenesis of GCT is poorly understood. The purpose of this study was to harvest and culture primary cell lines from clinical specimens of GCT of bone and identify specific bone degradation proteases (matrix metalloproteinases: MMP-2, MMP-9) produced by the neoplastic stromal cells in vitro. With approval by the McMaster University Biohazards and Ethics Review Boards, we acquired consent from five patients with GCT of bone, and harvested specimens intraoperatively. The specimens were chopped in DMEM containing 10% Fetal Bovine Serum, 2 mM L-glutamine, 100 U/ml penicillin and 100 mg/ml streptomycin. The cell suspensions were incubated at thirty-seven degrees (5% CO2 and 95% air) and cultivated. The cells were grown to confluence and taken through several passages until only proliferative cells were present. Immunocytochemistry with TRAP (Tartrate Resistant Acid Phosphatase) was used to confirm the stem cell origin of the propagative cells. Protein electrophoresis with embedded gelatin was used for detecting protease activity (MMP-2, MMP-9) on cell lysates and medium. P-aminophenyl mercuric acetate (APMA) was used to activate and ethylenediaminetetraacetic acid (EDTA) was used to block MMP-2 and MMP-9 activity. Our controls included serum free media, Human Osteosarcoma and Fibroblast cell lines. Immunocytochemistry with TRAP confirmed that our propagative cells were not hematopoietic in origin but rather mesenchymal. Protein electrophoresis on cell lysates and medium identified the protease activity of MMP-2 and MMP-9 with lytic bands at appropriate molecular weights. APMA activated MMP-2 more than MMP-9, as indicated by increased relative density of bands. EDTA blocked the activity of both MMPs. Our study confirmed the ability to cultivate the neoplastic stromal cells of GCT of bone from clinical specimens. Protein electrophoresis showed that activated MMP-2 and MMP-9 are secreted from the neoplastic stromal cells in vitro, suggesting a role for the tumor cells in bone destruction. These results are intriguing, as novel therapies in specific MMP inhibitors are currently underway for numerous disease processes.