header advert
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 110 - 110
2 Jan 2024
Barbosa F Silva J Garrudo F Cabral J Morgado J Ferreira F
Full Access

Bone defects can result from different incidents such as acute trauma, infection or tumor resection. While in most instances bone healing can be achieved given the tissue's innate ability of self-repair, for critical-sized defects spontaneous regeneration is less likely to occur, therefore requiring surgical intervention. Current clinical procedures have failed to adequately address this issue. For this reason, bone tissue engineering (BTE) strategies involving the use of synthetic grafts for replacing damaged bone and promoting the tissue's regeneration are being investigated. The electrical stimulation (ES) of bone defects using direct current has yielded very promising results, with neo tissue formation being achieved in the target sites in vivo. Electroactive implantable scaffolds comprised by conductive biomaterials could be used to assist this kind of therapy by either directing the ES specifically to the damaged site or promoting the integration of electrodes within the bone tissue as a coating. In this study, we developed novel conductive heat-treated polyacrylonitrile/poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PAN/PEDOT:PSS) nanofibers via electrospinning capable of mimicking key native features of the bone tissue's extracellular matrix (ECM) and providing a platform for the delivery of exogenous ES. The developed scaffolds were doped with sulfuric acid and mineralized in Simulated Body Fluid to mimic the inorganic phase of bone ECM. As expected, the doped PAN/PEDOT:PSS nanofibers exhibited electroconductive properties and were able to preserve their fibrous structure. The addition of PEDOT:PSS was found to improve the bioactivity of the scaffolds, with a more significant in vitro mineralization being obtained. By seeding the scaffolds with MG-63 osteoblasts and human mesenchymal stem/stromal cells, an increased cell proliferation was observed for the mineralized PAN/PEDOT:PSS nanofibers, which also registered an increased expression of key osteogenic markers (e.g Osteopontin). Our findings appear to corroborate the promising potential of the generated nanofibers for future ES-based BTE applications.

Acknowledgements: The authors thank FCT for funding through the projects InSilico4OCReg (PTDC/EME-SIS/0838/2021), BioMaterARISES (EXPL/CTM-CTM/0995/2021) and OptiBioScaffold (PTDC/EME-SIS/32554/2017, POCI-01- 0145-FEDER- 32554), the PhD scholarship (2022.10572.BD) and through institutional funding to iBB (UIDB/04565/2020 and UIDP/04565/2020), Associate Laboratory i4HB (LA/P/0140/2020) and IT (UIDB/50008/2020).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 75 - 75
2 Jan 2024
Silva J Udangawa R Cabral JS Ferreira F Linhardt R
Full Access

Electrospinning is an advantageous technique for cartilage tissue engineering (CTE) applications due to its ability to produce nanofibers recapitulating the size and alignment of the collagen fibers present within the articular cartilage superficial zone. Moreover, coaxial electrospinning allows the fabrication of core-shell fibers able to encapsulate and release bioactive molecules in a sustained manner. Kartogenin (KTG) is a small heterocyclic molecule, which was demonstrated to promote the chondrogenic differentiation of human bone marrow-derived mesenchymal stem/stromal cells(hBMSCs)[1].

In this work, we developed and evaluated the biological performance of core-shell poly(glycerol sebacate)(PGS)/poly(caprolactone)(PCL) aligned nanofibers (core:PGS/shell:PCL) mimicking the native articular cartilage extracellular matrix(ECM) and able to promote the sustained release of the chondroinductive drug KTG[2].

The produced coaxial aligned PGS/PCL scaffolds were characterized in terms of their structure and fiber diameter, chemical composition, thermal properties, mechanical performance under tensile testing and in vitro degradation kinetics, in comparison to monoaxial PCL aligned fibers and respective non-aligned controls. KTG was incorporated into the core PGS solution to generate core-shell PGS-KTG/PCL nanofibers and its release kinetics was studied by HPLC analysis. KTG-loaded electrospun aligned scaffolds capacity to promote hBMSCs chondrogenic differentiation was evaluated by assessing cell proliferation, typical cartilage-ECM production (sulfated glycosaminiglycans(sGAG)) and chondrogenic marker genes expression in comparison to non-loaded controls. All the scaffolds fabricated showed average fiber diameters within the nanometer-scale and the core-shell structure of the fibers was clearly confirmed by TEM. The coaxial PGS-KTG/PCL nanofibers evidenced a more sustained drug release over 21 days. Remarkably, in the absence of the chondrogenic cytokine TGF-β3, KTG-loaded nanofibers promoted significantly the proliferation and chondrogenic differentiation of hBMSCs, as suggested by the increased cell numbers, higher sGAG amounts and up-regulation of the chondrogenic genes COL2A1, Sox9, ACAN and PRG4 expression. Overall, our results highlight the potential of core-shell PGS-KTG/PCL aligned nanofibers for the development of novel MSC-based CTE strategies.

Acknowledgements: The authors thank FCT for funding through the project InSilico4OCReg (PTDC/EME-SIS/0838/2021) and to institutions iBB (UID/BIO/04565/2020) and Associate Laboratory I4HB (LA/P/0140/2020).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 60 - 60
2 Jan 2024
Decarli M Seijas-Gamardo A Morgan F Wieringa P Baker M Silva J Moraes A Lorenzo M Mota C
Full Access

Cartilage lesions often undergo irreversible progression due to low self-repair capability of this tissue. Tissue engineered approaches based in extrusion bioprinting of constructs loaded with stem cell spheroids may offer valuable alternatives for the treatment of cartilage lesions. Human mesenchymal stromal cell (hMSC) spheroids can be chondrogenically differentiated faster and more efficiently than single cells. This approach allows obtaining larger tissues in a rapid, controlled and reproducible way. However, it is challenging to control tissue architecture, construct stability, and cell viability during maturation. In this study we aimed at the development of a reproducible bioprinting process followed by post-bioprinting chondrogenic differentiation procedure using large quantities of hMSC spheroids encapsulated in a xanthan gum-alginate hydrogel. Multi-layered constructs were bioprinted, ionically crosslinked, and chondrogenically differentiated for 28 days. The expression of glycosaminoglycan, collagen II and IV were observed. After 56 days in culture, the bioprinted constructs were still stable and show satisfactory cell metabolic activity with profuse extracellular matrix production. These results showed a promising procedure to obtain 3D cartilage-like constructs that could be potential use as stable chondral tissue implants for future therapies.

Acknowledgments: The National Council for Scientific and Technological Development (CNPq, Brazil – Grants # 314 724/2021-4, 307 829/2018-9, 430 860/2018-8, 142 050/2018-0 and 465 656/2014-5), the Coordination for the Improvement of Higher Educational Personnel (CAPES, Brazil – PrInt 88 887.364849/2019-00 and PrInt 88 887.310405/2018-00), the Fund for Support to Teaching, Research and Extension from the University of Campinas (FAEPEX/UNICAMP, Brazil – Grants # 2921/18, 2324/21), and the European Union's Horizon 2020 JointPromise project – Precision manufacturing of microengineered complex joint implants, under grant agreement 874 837 are acknowledged for the financial support of this study.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 138 - 138
2 Jan 2024
Silva J Garrudo F Meneses J Marcelino P Barbosa F Moura C Alves N Pascoal-Faria P Ferreira F
Full Access

The growing number of non-union fractures in an aging population has increased the clinical demand for tissue-engineered bone. Electrical stimulation (ES) has been described as a promising strategy for bone regeneration treatments in several clinical studies. However the underlying mechanism by which ES augments bone formation is still poorly understood and its use in bone tissue engineering (BTE) strategies is currently underexplored. Additive manufacturing (AM) technologies (Fused Deposition Modeling/3D Printing) have been widely used in BTE due to their ability to fabricate scaffolds with a high control over their structural and mechanical properties in a reproducible and scalable manner. Thus, in this work, we combined AM methods with conductive biomaterials and ES to enhance the osteogenic differentiation of human bone marrow-derived mesenchymal stem/stromal cells (hBMSCs) envisaging improved BTE strategies.

First, we started by developing AM-based electro-bioreactor devices containing medical-grade electrodes (stainless steel and Ti6Al4V) to apply ES to monolayer 2D cultures and 3D cell-seeded scaffolds. Computer modeling(Finite Element Analysis-FEA) was employed to predict the magnitude/distribution of electrical fields within the ES devices and along the different conductive scaffolds. Prior to scaffold culture, 5 different ES protocols were tested in terms of their ability to promote hBMSCs proliferation and osteogenic differentiation in 2D cultures. The best performance ES protocol was then used in two different AM-based BTE strategies: 1) Two different conductive scaffolds (conductive poly lactic acid (PLA) and titanium) were seeded with hBMSCs and cultured for 21 days under osteogenic medium conditions with and without ES and their biological performance was evaluated in comparison to non-conductive standard PLA scaffolds; 2) Different PEDOT:PSS-based coating solutions were screened to obtain PEDOT:PSS/Gelatin-coated 3D polycaprolactone (PCL) scaffolds with a high(11 S.cm-1) and stable electroconductivity. When cultured under ES, PEDOT:PSS/Gelatin-PCL scaffolds enhanced significantly hBMSCs osteogenic differentiation and mineralization(calcium deposition), highlighting their potential for BTE applications.

Acknowledgements: Funding received from FCT through projects InSilico4OCReg (PTDC/EME-SIS/0838/2021), OptiBioScaffold (PTDC/EME-SIS/4446/2020) and BioMaterARISES (EXPL/CTM-CTM/0995/2021), and to the institutions iBB (UIDB/04565/2020), CDRSP (UIDB/04044/2020) and Associate Laboratory i4HB (LA/P/0140/2020).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 72 - 72
4 Apr 2023
Silva-Henao J Pahr DH Reisinger A
Full Access

Primary implant stability is critical for osseointegration and subsequent implant success. Small displacements on the screw/bone interface are necessary for implant success, however, larger displacements can propagate cracks and break anchorage points which causes the screw to fail. Limited information is available on the progressive degradation of stability of an implanted bone screw since most published research is based on monotonic, quasi-static loading [1]. This study aims to address this gap in knowledge.

A total of 100 implanted trabecular screws were tested using multi-axial loading test set-up. Screws were loaded in cycles with the applied force increasing 1N in each load cycle. In every load cycle, Peak forces, displacements, and stiffness degradation (calculated in the unloading half of the cycle) where recorded. 10 different loading configurations where tested.

The damage vs displacement shows a total displacement at the point of failure between 0.3 and 0.4 mm while an initial stiffness reduction close to 40%. It is also shown that at a displacement of ~0.1 mm, the initial stiffness of every sample had degraded by 20% (or more) meaning that half of the allowable degradation occurred in the first 25-30% of the total displacement.

Other studies on screw overloading [1] suggests similar results to our concerning initial stiffness degradation at the end of the loading cycle. Our results also show that the initial stiffness degrades faster with relatively small deformations suggesting that the failure point of an implanted screw might occur before the common failure definition (pull-out force, for example). These results are of great significance since primary implant stability is better explained by the stiffness of the construct than by its failure point.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 22 - 22
1 Mar 2021
Makelov B Silva J Apivatthakakul T Gueorguiev B Varga P
Full Access

Osteosynthesis of high-energy metaphyseal proximal tibia fractures is still challenging, especially in patients with severe soft tissue injuries and/or short stature. Although the use of external fixators is the traditional treatment of choice for open comminuted fractures, patients' acceptance is low due to the high profile and therefore the physical burden of the devices. Recently, clinical case reports have shown that supercutaneous locked plating used as definite external fixation could be an efficient alternative. Therefore, the aim of this study was to evaluate the effect of implant configuration on stability and interfragmentary motions of unstable proximal tibia fractures fixed by means of externalized locked plating. Based on a right tibia CT scan of a 48 years-old male donor, a finite element model of an unstable proximal tibia fracture was developed to compare the stability of one internal and two different externalized plate fixations. A 2-cm osteotomy gap, located 5 cm distally to the articular surface and replicating an AO/OTA 41-C2.2 fracture, was virtually fixed with a medial stainless steel LISS-DF plate. Three implant configurations (IC) with different plate elevations were modelled and virtually tested biomechanically: IC-1 with 2-mm elevation (internal locked plate fixation), IC-2 with 22-mm elevation (externalized locked plate fixation with thin soft tissue simulation) and IC-3 with 32-mm elevation (externalized locked plate fixation with thick soft tissue simulation). Axial loads of 25 kg (partial weightbearing) and 80 kg (full weightbearing) were applied to the proximal tibia end and distributed at a ratio of 80%/20% on the medial/lateral condyles. A hinge joint was simulated at the distal end of the tibia. Parameters of interest were construct stiffness, as well as interfragmentary motion and longitudinal strain at the most lateral aspect of the fracture. Construct stiffness was 655 N/mm (IC-1), 197 N/mm (IC-2) and 128 N/mm (IC-3). Interfragmentary motions under partial weightbearing were 0.31 mm (IC-1), 1.09 mm (IC-2) and 1.74 mm (IC-3), whereas under full weightbearing they were 0.97 mm (IC-1), 3.50 mm (IC-2) and 5.56 mm (IC-3). The corresponding longitudinal strains at the fracture site under partial weightbearing were 1.55% (IC-1), 5.45% (IC-2) and 8.70% (IC-3).

From virtual biomechanics point of view, externalized locked plating of unstable proximal tibia fractures with simulated thin and thick soft tissue environment seems to ensure favorable conditions for callus formation with longitudinal strains at the fracture site not exceeding 10%, thus providing appropriate relative stability for secondary bone healing under partial weightbearing during the early postoperative phase.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 12 - 12
1 Dec 2018
Oliveira P Leonhardt M de Carvalho VC Kojima K Rossi F Silva J Lima A
Full Access

Aim

Determine the incidence of surgical site infections (SSI) after intramedullary nailing (IN) of femoral and tibial diaphyseal fractures and evaluate possible risk factors.

Method

Prospective observational cohort study. SSI was defined according to CDC-NHSN criteria and surveillance period for the occurrence of infection was 12 months instead of the 90 days currently recommended. Incidence was calculated as the ratio between the number of patients with SSI and total number of patients. Analysis of potential risk factors included patients-related factors (age, gender, body mass index, active foci of infection, immunosuppressive conditions, ASA score, alcohol or illicit drug abuse, smoking, polytrauma, etiology of fracture, type of fracture if closed or open, classification of fracture according to Müller AO, Tcherne classification for closed fractures, Gustilo-Anderson classification and duration of bone exposure for open fractures, previous stay in other healthcare services, use of external fixator, previous surgical manipulation at same topography of fracture, use of blood products); environmental and surgical-related factors (surgical wound classification, duration of surgery, hair removal, intraoperative contamination, antimicrobial use, presence of drains, hypothermia or hypoxia in the perioperative period, type of IN used, reaming, need for muscle or skin flap repair, use of negative pressure therapy) and microbiota-related factors (presence of preoperative colonization by Staphylococcus aureus or Acinetobacter baumannii).


The Journal of Bone & Joint Surgery British Volume
Vol. 40-B, Issue 3 | Pages 519 - 527
1 Aug 1958
Branco F da Silva Horta J

1. A case of essential osteolysis, progressing for thirteen years and involving the right femur and pelvis of a boy who was thirteen years old at the time of onset, is presented.

2. The histological appearance of fragments of bone and soft tissue removed from the affected thigh is described.

3. No evidence that might throw light on the etiology of the disease was obtained from biochemical investigations or from the histological studies.

4. None of the many lines of treatment that were tried had any effect upon the progress of the disease.