Advertisement for orthosearch.org.uk
Results 1 - 20 of 55
Results per page:
Bone & Joint Open
Vol. 5, Issue 4 | Pages 286 - 293
9 Apr 2024
Upadhyay PK Kumar V Mirza SB Shah N

Aims

This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged less than 50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component.

Methods

We describe the survival, radiological, and functional outcomes of 33 patients (38 THAs) at a mean follow-up of 27 years (25 to 32) between 1988 and 2018.


Abstract

Abstract:

Background

The dissatisfaction rate in patients operated with TKR is generally quoted to be around 20% in various registries in patients operated by multiple surgeons. The data of satisfaction rates following a TKR performed by single high volume surgeons is lacking.

Aim

To study the satisfaction rate and Net Promoter Score (NPS) of consecutively operated TKR patients by a single surgeon with a minimum 1 year follow up.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 25 - 25
1 Nov 2022
Shah N Bagaria V Deshmukh S Tiwari A Shah M
Full Access

Abstract

Aim

To study and compare the rise of Inflammatory markers post TKR operated by Medial parapatellar approach with tourniquet (MP) and by Subvastus approach used without tourniquet. (SV)

Materials and Methods

100 patients were operated for a TKR by two experienced Arthroplasty surgeons utilising either the MP approach or the SV approach. (50 knees each). The groups were well matched as regards age, degree of deformity, obesity, pre-op knee scores and co-morbidities. The patients were managed peri-operatively in an identical manner .5 inflammatory markers viz: IL-6, AST, LDH, CRP and ESR were measured pre-operatively and at 12, 24,48 and 72 hours postoperatively. Additionally, the patients' VAS score at these intervals and Morbidity Index was determined.


Bone & Joint Open
Vol. 3, Issue 3 | Pages 229 - 235
11 Mar 2022
Syam K Unnikrishnan PN Lokikere NK Wilson-Theaker W Gambhir A Shah N Porter M

Aims

With increasing burden of revision hip arthroplasty (THA), one of the major challenges is the management of proximal femoral bone loss associated with previous multiple surgeries. Proximal femoral arthroplasty (PFA) has already been popularized for tumour surgeries. Our aim was to describe the outcome of using PFA in these demanding non-neoplastic cases.

Methods

A retrospective review of 25 patients who underwent PFA for non-neoplastic indications between January 2009 and December 2015 was undertaken. Their clinical and radiological outcome, complication rates, and survival were recorded. All patients had the Stanmore Implant – Modular Endo-prosthetic Tumour System (METS).


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 5 - 5
1 Jan 2022
Mohammed R Shah P Durst A Mathai N Budu A Trivedi R Francis J Woodfield J Statham P Marjoram T Kaleel S Cumming D Sewell M Montgomery A Abdelaal A Jasani V Golash A Buddhiw S Rezajooi K Lee R Afolayan J Shafafy R Shah N Stringfellow T Ali C Oduoza U Balasubramanian S Pannu C Ahuja S
Full Access

Abstract

Aim

With resumption of elective spine surgery services following the first wave of COVID-19 pandemic, we conducted a multi-centre BASS collaborative study to examine the clinical outcomes of surgeries.

Methods

Prospective data was collected from eight spinal centres in the first month of operating following restoration of elective spine surgery following the first wave. Primary outcomes measures were the 30-day mortality rate and postoperative Covid-19 infection rate. Secondary outcomes analysed were the surgical, medical adverse events and length of inpatient stay.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 25 - 25
1 Sep 2021
Shah N Shafafy R Selvadurai S Benton A Herzog J Molloy S
Full Access

Introduction

Patients with metastatic spinal cord compression (MSCC) or unstable spinal lesions warrant early surgical consultation. In multiple myeloma, chemotherapy and radiotherapy have the potential to decompress the spinal canal effectively in the presence of epidural lesions. Mechanical stability conferred by bracing may potentiate intraosseous and extraosseous bone formation, thus increasing spinal stability. This study aims to review the role of non-operative management in myeloma patients with a high degree of spinal instability, in a specialist tertiary centre.

Methods

Retrospective analysis of a prospectively collected database of 83 patients with unstable myelomatous lesions of the spine, defined by a Spinal Instability Neoplastic Score (SINS) of 13–18. Data collected include patient demographics, systemic treatment, neurological status, radiological presence of cord compression, most unstable vertebral level and presence of intraosseous and extraosseous bone formation. Post-treatment scores were calculated based on follow-up imaging which was carried out at 2 weeks for cord compression and 12 weeks for spinal instability. A paired t-test was used to identify any significant difference between pre- and post-treatment SINS and linear regression was used to assess the association between variables and the change in SINS.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 39 - 39
1 Aug 2021
Rajan A Leong J Singhal R Siney P Shah N Board T
Full Access

Trabecular metal (TM) augments are designed to support an uncemented socket in revision surgery when adequate rim fit is not possible. We have used TM augments in an alternative arrangement, to contain segmental defects to facilitate impaction bone grafting (IBG) and cementation of a cemented socket. However, there is a paucity of literature supporting the use of this technique. We present one of the largest studies to date, reporting early outcomes of patients from a tertiary centre.

A single-centre retrospective analytical study of prospectively collected data was performed on patients who had undergone complex acetabular reconstruction using TM augments, IBG and a cemented cup. All patients operated between 2015 and 2019 were included. We identified 105 patients with a mean age of 74yrs. The mean follow-up was 2.3 years(1–5.5yrs). Our primary outcome measure was all-cause revision of the construct. The secondary outcome measures were, Oxford hip score (OHS), radiographic evidence of cup migration/loosening and post-op complications.

Eighty-four out of 105 patients belonged to Paprosky grade IIb, IIc or IIIa. Kaplan-Meier survivorship for all-cause revision was 96.36% (CI, 90.58–100.00) at 2 years with 3 failures. Two were due to early infection which required two-stage re-revision. The third was due to post-operative acetabular fracture which was then re-revised with TM augment, bone graft and large uncemented cup. Pre-op and post-op matched OHS scores were available for 60 hips(57%) with a mean improvement of 13 points. Radiographic analysis showed graft incorporation in all cases with no evidence of cup loosening. The mean vertical cup migration was 0.5mm (Range −5 to 7mm). No other complications were recorded.

This study shows that reconstruction of large acetabular defects during revision THA using a combination of TM augments to contain the acetabulum along with IBG to preserve the bone stock and a cemented socket is a reliable and safe technique with low revision rates and satisfactory clinical and radiographic results. Long term studies are needed to assess the possibility of preservation and regeneration of bone stock.


Bone & Joint Open
Vol. 1, Issue 9 | Pages 556 - 561
14 Sep 2020
Clough TM Shah N Divecha H Talwalkar S

Aims

The exact risk to patients undergoing surgery who develop COVID-19 is not yet fully known. This study aims to provide the current data to allow adequate consent regarding the risks of post-surgery COVID-19 infection and subsequent COVID-19-related mortality.

Methods

All orthopaedic trauma cases at the Wrightington Wigan and Leigh NHS Foundation Trust from ‘lockdown’ (23 March 2020) to date (15 June 2020) were collated and split into three groups. Adult ambulatory trauma surgeries (upper limb trauma, ankle fracture, tibial plateau fracture) and regional-specific referrals (periprosthetic hip fracture) were performed at a stand-alone elective site that accepted COVID-19-negative patients. Neck of femur fractures (NOFF) and all remaining non-NOFF (paediatric trauma, long bone injury) surgeries were performed at an acute site hospital (mixed green/blue site). Patients were swabbed for COVID-19 before surgery on both sites. Age, sex, nature of surgery, American Society of Anaesthesiologists (ASA) grade, associated comorbidity, length of stay, development of post-surgical COVID-19 infection, and post-surgical COVID-19-related deaths were collected.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 83 - 83
1 Feb 2020
Wolff D Newman J Shah N Morrissey P Conway C Gold R Tretiakov M Sedaghatpour D Pivec R Naziri Q Illical E
Full Access

Purpose

Infections in orthopaedic surgery are costly, debilitating complications. The search for new treatments and prevention strategies has led to the use of antibiotic-filled calcium sulfate (CaS) as a bone void filler that is both safe and effective. The purpose of this study was to examine the available data on the efficacy of this technology.

Methods

A literature search was performed for studies that evaluated the use of antibiotic-loaded CaS cement in orthopaedics published between inception of the databases to 2017. Selected studies included randomized controlled trials (RCTs) and observational studies published in the English language that met the following criteria: 1) patients underwent an orthopaedic procedure; 2) CaS cement with an antibiotic was used; and 3) at least one of our outcomes were mentioned. Outcomes included resolution of infection, complications related to treatment, subsequent surgeries, overall infection rate, fracture union rate, clinical outcomes, and wound complications. A total of 17 studies were included.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 86 - 86
1 Feb 2020
Khondakar N Shah N Murtaugh T Gold R Aylyarov A Pascal S Harb M Newman J Schwartz J Maheshwari A
Full Access

Summary

A meta-analysis was performed to compare rate of SSI after application of chlorhexidine vs. iodine in total joint arthroplasty. Chlorhexidine had significantly lower odds of SSI.

Introduction

Surgical site infections (SSI) are a significant source of morbidity and mortality. The optimal preoperative skin preparation in lower extremity total joint arthroplasty (TJA) remains debatable between chlorhexidine and iodine-containing solutions. This meta-analysis sought compare SSI rates between chlorhexidine cloth application the night before surgery plus povidone-iodine-alcohol (povidone-iodine) solution at surgery or only povidone-iodine at surgery.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 27 - 27
1 Apr 2019
Shah N Vaishnav M Patel M Wankhade U
Full Access

Objective

To evaluate the clinical and functional outcomes obtained by combination of high-flexion Freedom® Total Knee System (TKS) and mini-subvastus approach in total knee replacement patients.

Method

This is a retrospective, observational, real world study conducted at Mumbai in India from 2011 to 2016. All patients who were above the age of 18 and operated for total knee replacement (TKR) with mini-subvastus approach using Freedom (Maxx Medical) by the senior author were included. The Implant survivorship was the survey endpoint; primary endpoint was range of motion (ROM); and secondary endpoints were AKSS (American Knee Society Score) and WOMAC (Western Ontario and McMaster Universities Osteoarthritis) scores collected pre- and post-operatively.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 26 - 26
1 Nov 2017
Syam K Wilson-Theaker W Lokikere N Saraogi A Gambhir A Porter M Shah N
Full Access

With increasing burden of revision hip arthroplasty, one of the major challenge is the management of bone loss associated with previous multiple surgeries. Proximal femoral replacement (PFR) has already been popularised for tumour surgeries. The inherent advantages of PFR over allograft –prosthesis system, which is the other option for addressing severe bone loss include, early weight bearing and avoidance of non-union and disease transmission. Our study explores PFR as a possible solution for the management of complex hip revisions. Thirty consecutive hips (29 patients) that underwent PFR between January 2009 and December 2015 were reviewed retrospectively for their clinical and radiological outcomes. The Stanmore METS system was used in all these patients.

Mean age at the index surgery (PFR) was 72.69 years (range 50–89) with number of previous hip arthroplasties ranging from 1–5. At mean follow up of 32.27 months, there were no peri-prosthetic fractures and no mechanical failure of the implants. Clearance of infection was achieved in 80% of cases. There was 1 early failure due to intra-operative perforation of femoral canal needing further revision and two were revised for deep infection. Instability was noted in 26.7% (8) of the hips, of which, 87.5% (7) needed further revision with constrained sockets. Out of these 8 hips with instability, 5 had pre-operative infection. Deep infection was noted in 20% (6) of the hips, of which, 5 were primarily revised with PFR for septic loosening. However, further surgeries were essential for only 3 patients. One patient has symptomatic aseptic acetabular loosening and 1 had asymptomatic progressive femoral side loosening (lost to follow up).

Severe proximal femoral bone loss in complex revision arthroplasties has necessitated the use of PFR prosthesis. Our study supports the fact that PFR is probably a mechanically viable option for complex revisions. Significant numbers of dislocations and infections could be attributed to the poor soft tissue envelope around the hip. Further surgical techniques in the form use of dual mobility cups and silver coated PFR implants need to be explored.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 2 - 2
1 Nov 2017
Unnikrishnan PN Oakley J Wynn-Jones H Shah N
Full Access

The ideal operative treatment of displaced sub capital femoral fractures in the elderly is controversial. Recently, randomised controlled trials have suggested a better outcome with the use of total hip arthroplasty (THA) to treat displaced intra capsular fractures of the femur for elderly patients in good health. More recently the concept of dual mobility cups is being promoted to avoid dislocations in this cohort of patients. However, overall there is limited evidence to support the choice between different types of arthroplasty. Dislocation remains a main concern with THA, especially when a posterior approach is used.

We analysed the outcome of 115 primary THR (112 cements and 3 uncemented) THR using a posterior approach with soft tissue repair in active elderly patients presenting with displaced intra capsular femoral neck fractures. Size 28 mm head was used in 108 and a size 32 mm head in the rest. All surgery was performed by specialist hip surgeons.

Satisfactory results were noted in terms of pain control, return to pre-morbid activity and radiological evidence of bone implant osteo-integration. The 30-day mortality was nil. There were two dislocations and only one needed revision surgery due to recurrent dislocation.

In conclusion, with optimal patient selection, THA seems to provide a good functional outcome and pain relief in the management of displaced intracapsular femoral neck fractures. Excellent outcome can be achieved when done well using the standard cemented THR and with 28mm head. A good soft tissue repair and a specialist hip surgeon is preferable.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 10 - 10
1 Nov 2017
Sidharthan S Lokikere N Saraogi A Nagai H Wynn-Jones H Board T Shah N Porter M Kay P
Full Access

Background

One of the major concerns of hinge knees have been reported in literature is mechanical failure. Failure in the form of component fracture (2–10%) and hinge dislocation/ failure are worrisome. In addition, higher risk of aseptic loosening with hinge knee prosthesis has been attributed to stress transfer at bone cement interface.

Methods

Retrospective review of clinical and radiological results of 71 consecutive patients operated at single centre using Smiles hinge knee (Stanmore implants) between 2010 and 2014. Data was collected till the latest follow up. Mechanical failure due to any reason was considered as primary end point. Radiological evidence of aseptic loosening was considered to be one of the surrogate end points.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 7 - 7
1 Jul 2016
Lokikere N Saraogi A Sonar U Porter M Kay P Wynn-Jones H Shah N
Full Access

Distal femoral replacement is an operation long considered as salvage operation for neoplastic conditions. Outcomes of this procedure for difficult knee revisions with bone loss of distal femur have been sparsely reported.

We present the early results of complex revision knee arthroplasty using distal femoral replacement implant, performed for severe osteolysis and bone loss.

Retrospective review of clinic and radiological results of 25 consecutive patients operated at single centre between January 2010 and December 2014. All patients had single type of implant. All data was collected till the latest follow up. Re-revision for any reason was considered as primary end point.

Mean age at surgery was 72.2 years (range 51 – 85 years). Average number of previous knee replacements was 2.28 (range 1 to 6). Most common indications were infection, aseptic loosening and peri-prosthetic fracture. Average follow up was 24.5 months (range: 3–63 months). 1 patient died 8 months post-op due to unrelated reasons. Re-revision rate was 2/25 (8%) during this period. One was re-revised for aseptic loosening and one was revised for peri-prosthetic fracture of femur. Two other peri-prosthetic fractures were managed by open reduction and internal fixation. All 3 peri-prosthetic fractures occurred with low energy trauma.

It is noteworthy that there was no hinge or mechanical failures of the implant. Peri-prosthetic fracture in 12% of patients in this series is of concern. There are no similar studies to compare this data with. The length of the stem, type of fixation of the stem, weight of the distal femoral component of implant can be postulated as factors contributing to risk of peri-prosthetic fracture.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_13 | Pages 3 - 3
1 Jun 2016
Lokikere N Jakaraddi C Wynn-Jones H Shah N
Full Access

Primary total hip replacement (THR) in patients with abnormal/altered proximal femoral anatomy/narrow canals presents a technical challenge. There are only limited standard prosthetic stems available to deal with narrow canals or abnormal morphology. Many prefer to use expensive custom implants which often have a lag time to manufacture and do not always have long term published outcomes.

We present results of the Asian C-stem (which is a standard implant available on the shelf) used in patients predominantly of Caucasian origin with abnormal proximal femoral anatomy.

We retrospectively reviewed clinic-radiological results of 131 patients (131 stems) who underwent primary THR using Asian C-stem at Wrightington Hospital till their latest follow up. Revision for any reason was considered as primary end point.

Mean age at surgery was 50.8 years (16 – 80). The 2 commonest indications were primary osteoarthritis (66 patients) and hip dysplasia (54 patients). Mean follow up was 43.5 months with a minimum follow up of 12 months and maximum follow up of 97 months. There were 2 recurrent dislocations and 1 hip subluxed twice. One dislocation needed revision surgery. 1 patient underwent acetabular revision for loosening. There was no stem failure, obvious loosening or loss of fixation in any patients in our series with regards to the Asian C-stem. There were no infections and intra-operative perforations or fractures.

C-stem Asian is a reliable implant for patients undergoing THR with abnormal proximal femoral anatomy or narrow canals. Long term follow up is essential.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 28 - 28
1 Jan 2016
Arora B Shah N
Full Access

Background

A grossly deformed knee is believed to be an indication for PS -TKA. However, the role CR-TKA in such knees is unclear in the literature. Considering the obvious advantages of CR, we analysed the mid term follow up of CR knees in gross deformities.

Materials and Methods

1590 patients (1740 knees) underwent TKA between January 2011 to December 2012, out of which 570 knees had gross deformity (varus > 15°, FFD > 10°, valgus > 10°, recurvatum > 10). CR-TKA was performed for 540 knees and were included in our study. Subvastus approach was used for all knees. Average age being 68 years, mean BMI being 32 and average weight 70 kgs. Intraoperatively, POLO test was used to ensure PCL stability, further confirmed by direct palpation. Femoral roll-back was found adequate.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 27 - 27
1 Jan 2016
Arora B Shah N
Full Access

Background

Subvastus approach for Total Knee Arthropalsty (TKA) allows a faster recovery. It is traditionally not utilized for revision surgeries because of difficulty in exposure of the knee and eversion of the patella. It is considered to have limited indications. We hypothesized that revision TKA should not really pose a problem as the exposure gained is adequate with added advantage of preserving the extensor mechanism, thereby allowing faster functional recovery. We present an analysis of the use of subvastus approach for revision TKAs.

Materials and methods

50 patients (50 knees) 37 females + 13 males with mean age 68 years underwent revision total knee arthroplasty (TKA) by subvastus approach between January 2006 to January 2013. All patients were prospectively evaluated by pre- and postoperative Knee Society and function score. The average follow-up was 24 months (range from 1 to 3 years) with minimum 1 year follow-up. The indications for revisions were aseptic loosening (20 knees), infection (12 knees), instability (12 knees) and peri-prosthetic fractures (6 knees). Constrained condylar prosthesis (43 knees), hinged prosthesis (6 knees) and custom made prosthesis (1 knee) were fixed using the subvastus approach. Infected knees underwent one or two staged revisions.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 39 - 39
1 Nov 2015
Syed M Hutt N Shah N Edge A
Full Access

Introduction

The longevity of total hip replacements in young active patients is a cause for concern as increased cyclical loading can result in early loosening of implants resulting in multiple revisions during the patient's lifetime. The study presented demonstrates excellent survival of the HAC-coated femoral stems in young active individuals.

Patients/Materials & Methods

33 Patients under 50 years of age underwent 38 total hip arthroplasties using the JRI Furlong HAC-coated femoral stem. The retrospective evaluation of the prospectively collected data of the cohort at 17 to 25 years is presented.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 749 - 754
1 Jun 2015
Syed MA Hutt NJ Shah N Edge AJ

This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged <  50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component. This represents an update of previous reports of the same cohort at ten and 16 years, which were reported in 2004 and 2009, respectively. We describe the survival, radiological and functional outcomes at a mean follow-up of 21 years (17 to 25). Of the surviving 34 THAs, one underwent femoral revision for peri-prosthetic fracture after 21 years, and one patient (one hip) was lost to follow-up. Using aseptic loosening as the end-point, 12 hips (31.5%) needed acetabular revision but none needed femoral revision, demonstrating 100% survival (95% confidence interval 89 to 100).

In young patients with high demands, the Furlong HAC–coated femoral component gives excellent long-term results.

Cite this article: Bone Joint J 2015;97-B:749–54.