We present the mid-term results of our consecutive series of 155 hips treated with ASR XL Acetabular System (ASR-XL) for large-diameter metal-on-metal total hip arthroplasty and with DePuy ASR Hip Resurfacing System (ASR) for hip resurfacing. 114 ASR-XL and 41 ASR were implanted between 2004 and 2008 in 145 patients (69 men and 76 women) with a mean age of 57 years. Twenty-one patients (23 hips) resulted lost to follow-up. All patients were recalled and monitored periodically with clinical, hematological and radiological evaluation. Average follow-up of the 155 hips was 72 months (1 to 104). The mean follow-up, excluding revised patients and those lost to follow-up, was up to 89 months.Introduction:
Methods:
Previous studies have indicated poor outcomes and high complication rate in patients having revision of metal-on-metal (MoM) hip implants resulting from adverse local tissue reactions. Metal ions released by MoM bearings may potentially increase infection occurrence in patients with failed implants. We reviewed all patients at our institution who sustained revision of a failed large-head metal-on-metal hip implant to determine if infection-related complications are associated with the elevation of serum metal ions concentration.Background
Questions/purposes