header advert
Results 1 - 1 of 1
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 3 - 3
1 Apr 2019
Seo SG Kim JI
Full Access

Introduction

Although weight-bearing CT of the foot definitely reflects the morphology and deformity of joint, it is hard to obtain the standing CT due to difficulty of availability. Although 3D imaging reconstruction using radiographs has been reported in other joints, there is no study about foot joint. The purpose of this study is to develop a semi-automatic method based on a deformable surface fitting for achieving the weight-bearing 3D model reconstruction from standing radiographs for foot.

Methods

Our method is based on a Laplacian surface deformation framework using a template model of foot. As pre- processing step, we obtained template surface meshes having the average shapes of foot bones (talus, calcaneus) from standing CT images (Planmed Verity) in 10 normal volunteers. In the reconstruction step, the surface meshes are deformed following guided user inputs with geometric constraints to recover the target shapes of 30 patients while preserving average bone shape and smoothness. Finally, we compared reconstructed 3D model to original standing CT images. Analysis was performed using Dice coefficients, average shape distance, maximal shape distance.