Most navigation systems for TKR help in the alignment of bulky cutting jigs. We hypothesized that TKR bone cutting could be done free hand without cutting jigs, by navigating a bone saw directly. This would allow smaller incisions, faster recovery time and simpler procedures. The goal of this study was to evaluate the results of free-hand cutting by using in-house developed CAOS software against cuts with traditional jigs.

Experiments were carried out on the five planar cuts of the TKR distal femur, using first the conventional cutting jig and then freehand. The Freehand cutting system navigated and displayed 3D realistic models of the saw, the bone and the planes along which the blade should be orientated. Two experienced arthroplasty surgeons and one engineer performed the experiments on 18 identical synthetic femurs. Each performed one using jigs and five freehand. The experiments were timed and > 50 direct measurements were made for each (cut) bone with a computer digitizer, digital caliper and protractor to assess their quality.

Surgeon’s comments, qualitative and quantitative assessments of the cuts proved the concept’s feasibility and its encouraging potential. The engineer’s time improvement with freehand navigation has implications for easier TKR for trainee surgeons.