Suthar A Yukata K Azuma Y Suetomi Y Yamazaki K Seki K Sakai T Fujii H

Aims

This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA).

Methods

We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 137 - 137
1 Apr 2019
Seki T Seki K Tokushige A Imagama T Ogasa H
Full Access

Introduction

It has been reported that the tibial articular surface of coronal aligment is parallel to the floor in the whole-leg standing radiographs of the normal knee. The purposes of this study are to investigate the relationship between the tibial articular surface and the ground on the whole-leg standing radiographs after total knee arthroplasty(TKA).

Sturdy Design and Methods

20 knees after TKA were studied retrospectively. The 20 participants were mean age at 76.7 years; and 3 male and 17 female. Using whole-leg standing radiographs, we mesuared the pre- and postoperative hip-knee- ankle angle(HKA), the tibial joint line angle(TJLA), and the tibial component Coronal tibial angle(CTA). The difference in each parameter was compared and examined.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 201 - 201
1 Mar 2013
Imagama T Tokushige A Sakka A Seki K Muto M Taguchi T
Full Access

Introduction

The goal of treating artificial joint infection is to relieve the infection quickly and re-establish joint function, but many patients have underlying diseases, and treatment is often made problematic by the diversity of the causative bacteria. In this study we assessed the factor that enabled revision arthroplasty in patients with infection after artificial hip arthroplasty, including bipolar hip arthroplasty, in our hospital.

Subjectives and Methods

The subjects were the 16 patients (16 hips) with infection after hip arthroplasty who were treated in our hospital during the past 10 years. There were 7 males and 9 females, and their mean age was 69.8 years. Primary total hip arthroplasty had been performed in 6 hips, revision hip arthroplasty in 8 hips, and bipolar hip arthroplasty in 2 hips. Infected implants were removed as soon as possible and delayed reimplantations with an interval antibiotic spacer were attempted in all patients. 9 hips were successful in reimplantation (reimplantation group) and 7 hips were impossible (No reimplantation group). In this study we investigated age, complications, body mass index (BMI), body temperature, pain, rate of resistant bacteria, number of hip surgery prior to infection and clinical manifestations compared to two groups.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 324 - 324
1 Mar 2013
Seki K Tanaka H Sakka A Tokushige A Imagama T Taguchi T
Full Access

Background

Excellent results with use of tapered wedged cementless stem have been reported. The purpose of this study was to clarify the indication of tapered wedged cementless stems for patients with poor bone quality.

Method

Sixty-five hemiarthroplasties in 79 patients with diagnosis of femoral neck fracture were performed between February 2004 and August 2011. 14 patients were lost to follow-up after surgery, and it is 19 patients among the leaving 65 patients had the stovepipe canal. There were 2 men and 16 women, with a mean age at time of surgery 85 years (range, 75–92 years). All components were tapered wedged cementless stem (LINEAR: Encore, Kinectiv: ZIMMER). Evaluation of patient followed includes radiographic analysis (canal flare index, canal fill rate, stem alignment, bone reaction, and stem stability) and recording complication.