header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 72 - 72
1 Dec 2016
Karlsen ØE Borgen P Bragnes BO Figved W Grøgaard B Rydinge J Sandberg L Snorrason F Wangen H Witso E Westberg M
Full Access

Aim

Prosthetic joint infection (PJI) is a much feared complication to arthroplasty with significant patient morbidity. Rifampin is increasingly used in staphylococcal PJIs treated with debridement and retention of the prosthesis. The evidence supporting rifampin combination therapy in PJIs is limited due to the lack of controlled studies. The aim of this study is to evaluate the effect of adding rifampin to conventional antimicrobial therapy in early staphylococcal PJIs treated with debridement and retention.

Method

In this multicentre randomized controlled trial, 99 patients with PJI after hip and knee arthroplasties were enrolled. All patients underwent a standardized surgical debridement. 65 patients had PJI caused by staphylococci and further included in the study. They were randomly assigned to receive rifampin or not in addition to standard antimicrobial therapy with cloxacillin, or vancomycin in case of methicillin resistance. They received parenteral antibiotics for two weeks, then oral antibiotics for 4 weeks. In case of methicillin resistance, vancomycin was administered i.v. for 6 weeks. The primary end point was no signs of infection after 2 wears follow-up.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 755 - 761
1 Jun 2015
Flatøy B Röhrl SM Rydinge J Dahl J Diep LM Nordsletten L

Cemented femoral stems with force closed fixation designs have shown good clinical results despite high early subsidence. A new triple-tapered stem in this category (C-stem AMT) was introduced in 2005. This study compares this new stem with an established stem of similar design (Exeter) in terms of migration (as measured using radiostereometric analysis), peri-prosthetic bone remodelling (measured using dual energy x-ray densitometry, DXA), Oxford Hip Score, and plain radiographs.

A total of 70 patients (70 hips) with a mean age of 66 years (53 to 78) were followed for two years. Owing to missing data of miscellaneous reasons, the final analysis represents data from 51 (RSA) and 65 (DXA) patients. Both stems showed a typical pattern of migration: Subsidence and retroversion that primarily occurred during the first three months. C-stem AMT subsided less during the first three months (p = 0.01), before stabilising at a subsidence rate similar to the Exeter stem from years one to two. The rate of migration into retroversion was slightly higher for C-stem AMT during the second year (p = 0.03). Whilst there were slight differences in movement patterns between the stems, the C-stem AMT exhibits good early clinical outcomes and displays a pattern of migration and bone remodelling that predicts good clinical performance.

Cite this article: Bone Joint J 2015;97-B:755–61.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 387 - 387
1 Jul 2010
Dahl J Rydinge J Rohrl S Snorrason F Nordsletten L
Full Access

Introduction: C-stem is a triple taper polished femoral stem. The rationale for this design is to achieve an evenly distributed proximal loading of the cement mantle. This design is thought to enhance stability of the stem inside the mantle and lead to bone remodelling medially. There is to our knowledge no randomized trial comparing this stem to a well documented stem. We chose to compare it to the best documented stem in the Norwegian arthroplasty register, the Charnley monoblock.

Methods: 70 patients scheduled for total hip replacement were randomized to either C-stem or Charnley monoblock. All received a 22 mm stainless steel head, OGGEE cup and Palacos Cement with Gentamycin. We used a transgluteal approach in all cases. Harris and Oxford hip scores were measured preoperatively and after two years. Standard X-rays were taken postoperatively and after two years. Radiostereometry (RSA) was done postoperatively and after 3,6,12 and 24 months.

Results: There was no significant difference in Harris or Oxford hip scores after two years.

RSA after two years: (table deleted)

Discussion: Polished tapered stems are designed to sink inside the mantle. Our results confirm this theory for the C-stem. The subsidence is comparable to other collarless tapered stems with good long-term survival. For all other migrations/rotations the C-stem is as stable as the Charnley monoblock. This predicts good long-term results for this stem.