The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 85 - 90
1 Jan 2011
Hooper GJ Rothwell AG Frampton C Wyatt MC

We have investigated whether the use of laminar-flow theatres and space suits reduced the rate of revision for early deep infection after total hip (THR) and knee (TKR) replacement by reviewing the results of the New Zealand Joint Registry at ten years.

Of the 51 485 primary THRs and 36 826 primary TKRs analysed, laminar-flow theatres were used in 35.5% and space suits in 23.5%. For THR there was a significant increase in early infection in those procedures performed with the use of a space suit compared with those without (p < 0.0001), in those carried out in a laminar-flow theatre compared with a conventional theatre (p < 0.003) and in those undertaken in a laminar-flow theatre with a space suit (p < 0.001) when compared with conventional theatres without such a suit. The results were similar for TKR with the use of a space suit (p < 0.001), in laminar-flow theatres (p < 0.019) and when space suits were used in those theatres (p < 0.001). These findings were independent of age, disease and operating time and were unchanged when the surgeons and hospital were analysed individually.

The rate of revision for early deep infection has not been reduced by using laminar flow and space suits. Our results question the rationale for their increasing use in routine joint replacement, where the added cost to the health system seems to be unjustified.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 413 - 418
1 Mar 2010
Rothwell AG Hooper GJ Hobbs A Frampton CM

We analysed data from the Oxford hip and knee questionnaires collected by the New Zealand Joint Registry at six months and five years after joint replacement, to determine if there was any relationship between the scores and the risk of early revision. Logistic regression of the six-month scores indicated that for every one-unit decrease in the Oxford score, the risk of revision within two years increased by 9.7% for total hip replacement (THR), 9.9% for total knee replacement (TKR) and 12.0% for unicompartmental knee replacement (UKR). Our findings showed that 70% of the revisions within two years for TKR and 67% for THR and UKR would have been captured by monitoring the lowest 22%, 28% and 28%, respectively, of the Oxford scores. When analysed using the Kalairajah classification a score of < 27 (poor) was associated with a risk of revision within two years of 7.6% for THR, 7.0% for TKR and 24.3% for UKR, compared with risks of 0.7%, 0.7% and 1.8%, respectively, for scores > 34 (good or excellent).

Our study confirms that the Oxford hip and knee scores at six months are useful predictors of early revision after THR and TKR and we recommend their use for the monitoring of the outcome and potential failure in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 451 - 458
1 Apr 2009
Hooper GJ Rothwell AG Stringer M Frampton C

We have reviewed the rate of revision of fully cemented, hybrid and uncemented primary total hip replacements (THRs) registered in the New Zealand Joint Registry between 1999 and December 2006 to determine whether there was any statistically significant difference in the early survival and reason for revision in these different types of fixation. The percentage rate of revision was calculated per 100 component years and compared with the reason for revision, the type of fixation and the age of the patients.

Of the 42 665 primary THRs registered, 920 (2.16%) underwent revision requiring change of at least one component. Fully-cemented THRs had a lower rate of revision when considering all causes for failure (p < 0.001), but below the age of 65 years uncemented THRs had a lower rate (p < 0.01). The rate of revision of the acetabular component for aseptic loosening was less in the uncemented and hybrid groups compared with that in the fully cemented group (p < 0.001), and the rate of revision of cemented and uncemented femoral components was similar, except in patients over 75 years of age in whom revision of cemented femoral components was significantly less frequent (p < 0.02). Revision for infection was more common in patients aged below 65 years and in cemented and hybrid THRs compared with cementless THRs (p < 0.001). Dislocation was the most common cause of revision for all types of fixation and was more frequent in both uncemented acetabular groups (p < 0.001). The experience of the surgeon did not affect the findings.

Although cemented THR had the lowest rate of revision for all causes in the short term (90 days), uncemented THR had the lowest rate of aseptic loosening in patients under 65 years of age and had rates comparable with international rates of aseptic loosening in those over 65 years.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 322 - 322
1 May 2006
Rothwell AG Hobbs TF
Full Access

We recorded the preoperative posterior deltoid (PD) and postoperative elbow extensor torque (EET) to determine if it is possible to predict the likely EET following PD transfer.

A custom built device (Troidometer) was used to measure the preoperative torque generated by the PD under maximum isometric contraction with the shoulder at 90° of abduction and the coronal plane and the elbow flexed at 90°. At a minimum of 3 months post surgery the maximum isometric EET was measured again with the Troidometer.

In a total of 17 arms in 9 patients the average preoperative PD was 9.5 Nm and the average post operative EET was 5.4 Nm or 57% of the PD preoperative torque. A paired sample test demonstrated a highly significant decrease (P = 0.001) and a correlation coefficient of 0.8 between the pre and post operative data. If a poor result from a revised transfer is excluded then the average EET is 60% of preoperative torque.

Based on this data it can be predicted that approximately 60% of the pre operative PD torque will postoperatively be converted to EET.


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 3 | Pages 588 - 594
1 Aug 1973
Rothwell AG Bentley G

1. Twelve trephine specimens of articular cartilage and subchondral bone taken from six fresh osteoarthritic femoral heads were incubated in a medium containing tritiated thymidine, and autoradiographs were prepared from serial sections five microns thick.

2. Scattered labelling of chondrocytes in sections from four of the six femoral heads was demonstrated. No more than four labelled cells were seen in any one section. About half were found in typical chondrocyte clusters.