Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 10 - 10
1 Oct 2014
Richter P Schicho A Gebhard F
Full Access

Minimally invasive placement of iliosacral screws (SI-screw) is becoming the standard surgical procedure for sacrum fractures. Computer navigation seems to increase screw accuracy and reduce intraoperative radiation compared to conventional radiographic placement. In 2012 an interdisciplinary hybrid operating theatre was installed at the University of Ulm. A floor-based robotic flat panel 3D c-arm (Artis zeego, Siemens, Germany) is linked to a navigation system (BrainLab Curve, BrainLab, Germany). With a single intraoperative 3D scan the whole pelvis can be visualised in CT-like quality. The aim of this study was to analyse the accuracy of SI-screws using this hybrid operating theater.

32 SI-screws (30 patients) were included in this study. Indications ranged from bone tumour resection with consecutive stabilisation to pelvic ring fractures. All screws were implanted using the hybrid operating theatre at the University of Ulm. We analysed the intraoperative 3D scan or postoperative computed tomography and classified the grade of perforation of the screws in the neural foramina and the grade of deviation of the screws to the cranial S1 endplate according to Smith et al. Grade 0 stands for no perforation and a deviation of less than 5 °. Grade 1 implies a perforation of less than 2 mm and a deviation of 5–10°, grade 2 a perforation of 2–4 mm and a deviation of 10–15° and grade 3 a perforation of more than 4 mm and a deviation of more than 15°. All patients were tested for intra- and postoperative neurologic complications and infections. The statistical analysis was executed using Microsoft Excel 2010.

32 SI-screws were implanted in the first 20 months after the hybrid operating theatre had been established in 2012. All 30 patients were included in this study (15 men, 15 women). The mean age was 59 years ±23 (13–95 years). 20 patients received a single screw in S1 (66.7%), 1 patient 2 unilateral screws in S1 and S2 (3.3%), one patient 2 bilateral screws in S1 (3.3%) and 8 patients a single screw stabilising both SI-joints (26.7%). 27 screws showed no perforation (84.4%), 1 screw a grade 1 perforation (3.1%) and 4 screws a grade 2 perforation (12.5%). There was no grade 3 perforation. Furthermore there was no perforation of the neural foramina or the ventral cortex in the axial plane of the SI-screws stabilising one SI-joint (24 screws). Only single SI-screws bridging both SI joints showed a perforation of the neural foramina (37% grade 0, 12.5% grade 1, 50% grade 2, 0% grade 3).

In the frontal plane 23 screws (71.9%) showed a deviation of less than 5°. In 5 screws a grade 1 deviation (15.6%) and in 4 screws a grade 2 deviation (12.5%) could be found. There was no grade 3 deviation. There were no infections or neurological complications.

The high image quality and large field of view in combination with an advanced navigation system is a great benefit for the surgeon. All SI-screws stabilising only one joint showed completely intraosseous placement. Single SI-screws bridging 2 SI-joints intentionally perforated the neural foramina ventrally in 5 cases because of dysmorphic sacral anatomy. This makes image-guided implantation of SI-screws in a hybrid operating theatre a very safe procedure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 97 - 97
1 Aug 2013
Richter P Rahmanzadeh T Gebhard F Krischak G Arand M Weckbach S Kraus M
Full Access

INTRODUCTION

Isolated injuries of the sacral bone are rare. The pathomechanism of these injuries are usually high velocity accidents or falls from large heights. The computer-assisted implantation of iliosacral screws (SI-screw) becomes more important in the treatment of dorsal pelvic ring fractures. The advantage of the minimal-invasive screw placement is the reduction of the non-union and deep wound infection rate. Another advantage of computer-navigated SI-screw placement is the reduction of intraoperative radiation for the patient and the surgical staff. The purpose of this study was to analyse the position of navigated iliosacral screws.

METHODS

In the study group 74 screws (49 patients) were included and radiologically analysed. All screws were implanted using 3D-navigation (BrainLAB Vector Vision, Brainlab, Germany). Navigation was always executed with the same 3D c-arm (ARCADIS Orbic 3D, Siemens, Germany) and navigation system. We determined the grade of perforation and angular deviation in the postoperative CT-scans in all screws. The classification was performed according to Smith et al in 4 grades. Grade 0 implies no perforation and grade 1 a perforation less than 2 mm. Grade 2 correlates a perforation of 2–4 mm and grade 3 a perforation of more than 4 mm. Furthermore the intra- and postoperative complications as well as the body-mass-index, the co-morbidities and the duration of radiation were documented. The statistical analysis was executed using Microsoft Excel 2003.