Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 93 - 93
1 Apr 2018
Boffano M Pellegrino P Ratto N Giachino M Albertini U Aprato A Boux E Collo G Ferro A Marone S Massè A Piana R
Full Access

Introduction and Purposes

Custom made acetabular prosthesis are a valid option for the reconstruction after the resection of pelvic tumors. They should guarantee a stable and reliable reconstruction for the expected survival of the patient. Nevertheless in many cases periacetabular metastatic lesions have been compared to high grade (IIIA-B) Paprosky defects, but treated with low or intermediate longevity implants. Some complex post-traumatic scenarios or total hip arthroplasty (THA) multiple failures need a reconstruction according to oncologic criteria to fill in the huge defect and to obtain an acceptable function. The aim of the study is to compare 3D custom-made implants for tumors and for THA failures.

Materials and Methods

Three custom-made implants after tumor resection (group A: 1 chondroblastic osteosarcoma, 1 bifasic synovialsarcoma, 1 high grade chondrosarcoma) were evaluated and compared to 3 acetabular complex reconstructions after non-oncologic bone defect (group B: 3 cases of aseptic loosening after at least 2 revisions). All the implants were case-based designed, 3D printed, and realized with porous or trabecular surfaces on a Titanium base prosthesis. Age range 16–70 ys in oncologic patients and 60–75 ys in non-oncologic patients. The bone defect to be reconstructed after tumor resection was classified according to Enneking zones (1 type 1-2-3 resection, 1 type 2 resection, 1 partial type 2 resection). Non-oncologic cases were comparable in term of remaining bone stock and classified according to Paprosky classification for acetabular defects as 1 type IIIA an 2 type IIIB. Complications, MSTS functional score, necessity of walking-aids were evaluated at minimum follow up of 1 year.