Bearing surfaces used for total hip arthroplasty must have characteristics including bio-compatibility, low friction and low wear rate. Bearing combinations are generally characterised as Soft on Hard/Hard. In general, all newer bearing combinations have reduced wear but may present with other issues that impact on patient outcomes. The Australian Orthopaedic Association – National Joint Replacement Registry classifies bearing surfaces into six categories. These are metal on polyethylene, ceramic on polyethylene, metal on metal, ceramic on ceramic, ceramic on metal and a sixth category relating to a small number of procedures where the bearing surface is yet to be classified. 147,422 conventional total hip arthroplasty procedures have been recorded by the Registry between 1 September 1999 and 31 December 2008 and analysis has been performed of the cumulative percentage revision in relation to bearing surface.Introduction
Materials